Canopen® and J1939: Pressure Transmitter With Digital Output
Canopen® and J1939: Pressure Transmitter With Digital Output
Canopen® and J1939: Pressure Transmitter With Digital Output
TECHNICAL DATA
Pressure ranges (2)
from 4 to 1000 bar (see table)
Power supply
8 … 32 Vdc
Signal output
Digital CANopen® DS404 profile
Digital J1939
Non-Linearity (BFSL)
± 0.15% FS (typical) ± 0.25% FS (max)
Hysteresis
+ 0.1% FS (typical) + 0.15% FS (max)
KHC pressure transmitters are based on film sensing
Repeatability
element deposited on stainless steel diaphragm.
± 0.025% FS (typical) ± 0.05% FS (max)
Thanks to the latest state of the art SMD electronics Zero & Span setting tolerance
and compact all stainless steel construction, this pro-
± 0.15% FS (typical) ± 0.25% FS (max)
ducts are extremely robust and reliable, specially suita-
ble for mobile hydraulics applications. Accuracy at room temperature (1)
<± 0.5% FS
In particular the KHC series combines high accuracy
Overvoltage protection
with temperature stability, resistance to extreme envi-
ronmental conditions and digital outputs with mobile 40 Vdc max
hydraulics typical protocols. The model KHC is availa- Wetted parts
ble with either CANopen® or J1939 protocol.
Stainless steel Inox AISI 430F (1.4104) and 17-4 PH (1.4542)
Developed to ensure a robust and high-performance Housing
solution for applications such as agricultural machines, Stainless steel Inox AISI 304 (1.4301)
contruction machines and material handling
Insulation voltage
equipments.
500 Vdc
The digital signal, in addition to the pressure measure- Long term stability
ment, also contains the data related to the temperature
<± 0.2% FS/per year
of the device.
Operating temperature range
The instrument is delivered preconfigured and ready -40 … +125°C (process and storage) -40 … +105°C (ambient)
to be used without any further effort. Custom configu-
Compensated temperature range
rations are also possible, to be specified on order, or
-20 … +85°C
Temperature effects over compensated range (zero)
± 0.01%FS/°C typical (± 0.02%FS/°C max)
Temperature effects over compensated range (span)
± 0.01%FS/°C typical (± 0.02%FS/°C max)
Measuring rate
1 msec (1000 Hz) typical
Warm-up time (3)
<30 sec
Weight
150 gr
Mechanical Shock
100g/11 ms according to IEC 60068-2-27
Vibrations
20g at 10 Hz … 2000 Hz according to IEC 60068-2-6
Ingress protection
IP67/IP69K with appropriate mating connector plugged in
programmable by the user.
1) Incl. Non-Linearity, Hysteresis, Repeatability, Zero-offset
Output short circuit and reverse polarity protection
and Span-offset tolerance (acc. to IEC 61298-2) Yes
2) The operating pressure range is intended from 0.5 to
EC Conformity
100% FS
3) Time within which the rated performance ia achieved According to Directive 2014/30/EU
PRESSURE RANGES
RANGES
4 6 10 16 20 25 40 60 100 160 200 250 400 600 1000
(Bar)
Overpressure
8 12 20 32 40 50 80 120 200 320 400 500 800 1200 1200
(Bar)
Burst pressure
16 24 40 64 80 100 160 240 400 640 800 1000 1500 1500 1500
(Bar)
MECHANICAL DIMENSIONS
A - M12x1 connector
G 1/4
Hex 27 Hex 27
O-ring in Viton
2 12 2 13
A – M12x1 (5 pin)
2 1
3 4
5
The IP rating specified in this document normally applies with the suitable female connector plugged-in and properly wired.
SHIELD
1
POWER SUPPLY +
CONTROLLER 2
POWER SUPPLY -
3
CAN H
4
CAN L
5
CAN
0.5 mm
ACCESSORIES ON REQUEST
Connection A
CON031 CON041
EXTENSION CABLES
ELECTRICAL CONNECTION
ADDRESS
M12 x 1 (5 pin) A
001
Node ID (001 standard)
…
MEASUREMENT RANGE CANopen® and J1939
127
bar bar bar 248
B04U 4 B25U 25 B02C 200 … Node ID (J1939 only)
B06U 6 B04D 40 B25D 250 253
B01D 10 B06D 60 B04C 400
B16U 16 B01C 100 B06C 600 TERMINATION RESISTOR
B02D 20 B16D 160 B01M 1000 0 No resistor (standard)
1 Resistor 120 Ω
NON-LINEARITY
±0.25%FS BFSL M ACCESORIES
X None (standard)
BAUDRATE 1 CON 031 connector inclusive
1 Mbit/s 0 2 CON 041 connector inclusive
800 kbit/s 1
500 kbit/s 2
PARTICULARS
250 kbit/s (standard) 3*
00 None (standard)
125 kbit/s 4
100 kbit/s 5
50 kbit/s 6 CALIBRATION STANDARDS
20 kbit/s 7 Instruments manufactured by Gefran are calibrated
against precision pressure calibration equipment wich
* Only opt.3 available for J1939
is traceable to International Standards.
HEX WRENCH SIZE
Hex 27 mm 7
Description example: KHC-C-E-A-B04C-M-3-7 213-I-001-0-1-00
User manual, Electrical installation requirements and Conformity certificate are available on our website: www.gefran.com
GEFRAN spa reserves the right to make any kind of design or functional modification at any moment without prior notice.
GEFRAN spa
via Sebina, 74
25050 PROVAGLIO D’ISEO (BS) - ITALIA
tel. 0309888.1 - fax. 0309839063
Internet: http://www.gefran.com DTS_KHC_11-2016_ENG