Electronic

Pressure Switch
EDS 3300
with Menu Navigation to VDMA

3
Description: Technical data:
The EDS 3300 is a compact electronic Input data
pressure switch with integrated Measuring ranges -1..1; 1; 2.5; 6; 10; 16 bar
digital display for relative pressure Overload pressures 3; 3; 8, 18, 30, 48 bar
measurement in the low-pressure Burst pressures 5; 5; 12; 30; 50; 80 bar
range. Mechanical connection G1/4 A DIN 3852
It has a ceramic measuring cell with Threaded port DIN 3852-G1/4
thick-film strain gauge. The instrument Torque value 20 Nm
can have one or two switching outputs, Parts in contact with medium Mech. connection: Stainless steel
and there is the option of an additional Sensor cell: Ceramic
switchable analogue output signal Seal: FPM / EPDM
(4 .. 20 mA or 0 .. 10 V). (as per model code)
A special design feature of the Output data
EDS 3300 is that the display can be Accuracy to DIN 16086, ≤ ± 0.5 % FS typ.
rotated in two planes. The unit can Max. setting ≤ ± 1 % FS max.
be installed in almost any mounting (display, analogue output)
position and the display can be turned Repeatability ≤ ± 0.25 % FS max.
to the optimum position without Temperature drift ≤ ± 0.025 % FS / °C max. zero point
the usual additional expense of a ≤ ± 0.025 % FS / °C max. range
mechanical adapter. The 4-digit display Analogue output (optional)
can indicate the pressure in bar, psi or Signal selectable:
MPa. The user can select the particular 4 .. 20 mA load resistance max. 500 W
measurement unit. When changing to a 0 .. 10 V load resistance min. 1 kW
different measurement unit, the Switch outputs
EDS 3300 automatically converts all Type PNP transistor output
the switching settings to the new unit of Switching current max. 1.2 A
measurement. Switching cycles > 100 million
The main applications of the Reaction time < 10 ms
EDS 3300 are primarily in hydraulics Long-term drift ≤ ± 0.3 % FS typ. / year
and pneumatics, as well as in Environmental conditions
refrigeration and air conditioning Compensated temperature range -10 .. +70 °C
technology. Operating temperature range -25 .. +80 °C (-25 ... +60 °C acc. to UL spec.)
Storage temperature range -40 .. +80 °C
Special features: Fluid temperature range -25 .. +80 °C
 Menu navigation according to VDMA
mark EN 61000-6-1 / 2 / 3 / 4
 1 or 2 PNP transistor switching mark1) Certificate No. E318391
outputs, up to 1.2 A load
Vibration resistance to ≤ 10 g
per output DIN EN 60068-2-6 at 10 .. 500 Hz
 Accuracy ≤ ± 1 % FS Shock resistance to ≤ 50 g
 Optional analogue output selectable DIN EN 60068-2-29 (11 ms)
(4 .. 20 mA / 0 .. 10 V) Protection class to IEC 60529 IP 67
 4-digit digital display Other data
 Optimum alignment - can be Supply voltage 9 .. 35 V DC without analogue output
rotated in two planes (axes) 18 .. 35 V DC with analogue output
for use acc. to UL spec. - limited energy - according to
 Measured value can be displayed in 9.3 UL 61010; Class 2;
bar, psi or MPa UL 1310/1585; LPS UL 60950
 User-friendly due to Current consumption max. 2.455 A total
key programming max. 35 mA with inactive switching outputs
 Switching points and switch-back max. 55 mA with inactive switching outputs
hystereses can be adjusted and analogue output
E 18.369.2/11.13

independently Display 4-digit, LED, 7 segment, red,


 Many useful additional functions height of digits 7 mm
Weight ~ 120 g
Note: Excess voltage, override protection and short circuit protection are provided.
FS (Full Scale) = relative to complete measuring range
1)
Environmental conditions according to 1.4.2 UL 61010-1; C22.2 No 61010-1 49
Setting options: Model code:
All terms and symbols used for setting the
EDS 3300 as well as the menu structure EDS 3 3 X 6 – X – XXXX – V00 – X 1
comply with the specifications in the
VDMA Standard (VDMA 24574-1) for Mechanical connection
pressure switches. 4 = G1/4 A DIN 3852 (male)
The EDS 3300 can easily be adjusted via 9 = Threaded port DIN 3852-G1/4
three buttons. Electrical connection
6 = Male M12x1, 4 pole
Setting ranges for the switch
Output
outputs: 1 = 1 switching output
Measuring Lower Upper limit of 2 = 2 switching outputs
range limit of SP / FH 3 = 1 switching output and 1 analogue output
RP / FL Pressure ranges in bar
in bar in bar in bar
0001 (-1 .. 1 bar); 01.0; 02.5; 06.0; 0010; 0016
- 1. . 1 -0 .98 1. 00
Modification number
0 .. 1 0 .01 0 1. 000 V00 = Menu navigation in accordance with VDMA (Standard Sheet 24574)
0 . . 2.5 0 .02 5 2. 500
Seal material (in contact with fluid)
0 .. 6 0 .06 6. 00 F = FPM seal (e.g. for hydraulic oils)
0 . . 10 0 .10 10. 00 E = EPDM seal (e.g. for water, refrigerants)
0 . . 16 0 .20 16. 00 Connection material (in contact with fluid)
3
1 = Stainless steel
Measuring Min. difference Incre- Notes:
range betw. ment* On instruments with a different modification number, please read the label or the
RP and SP technical amendment details supplied with the instrument.
in bar & FL and FH in bar
Accessories:
- 1 .. 1 0.02 0.01
Appropriate accessories, such as electrical connectors, mechanical adapters, splash
0 .. 1 0.010 0.002
guards, clamps for wall-mounting etc can be found in the Accessories brochure.
0 .. 2.5 0.025 0.005
0 .. 6 0.06 0.01
0 .. 10 0.10 0.02
0 .. 16 0.20 0.05 Dimensions:
* All ranges given in the table
are adjustable by the increments
shown.
SP = switch point
RP = switch-back point
FL = pressure window lower value display
FH = pressure window upper value turns thru
270°

Additional functions:
 Switching mode of the switching outputs
adjustable (switching point function or
window function)
housing
 Switching direction of the switching turns thru
outputs adjustable (N/C or N/O function) 340°

 Switch-on and switch-off delay


adjustable from 0.00 .. 99.99 seconds
 Analogue output signal selectable
4 .. 20 mA or 0 .. 10 V
hex-SW27
 Pressure can be displayed in
measurement units bar, psi, MPa.
The scaling can also be adapted to
indicate force, weight, etc.
elastomer profile gasket
DIN 3869
Pin connections:
M12x1, 4 pole

male electr. conn. M12x1


4 pole

Pin EDS EDS EDS Note:


33X6-1 33X6-2 33X6-3 The information in this brochure relates to
the operating conditions and
E 18.369.2/11.13

1 +UB +UB +UB HYDAC electronic GmbH


applications described. Hauptstraße 27, D-66128 Saarbrücken
2 n.c. SP 2 Analogue For applications and operating conditions Telephone +49 (0)6897 509-01
3 0V 0V 0V not described, please contact the relevant Fax +49 (0)6897 509-1726
technical department. E-mail: electronic@hydac.com
4 SP 1 SP 1 SP 1 Subject to technical modifications. Internet: www.hydac.com

50

You might also like