NanoGrout CFG

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Construction Chemicals

NanoGrout CFG
Pre Mixed Grout for Post-Tensioned Cable Ducts
and Sonic Tubes in Concrete Piles

DESCRIPTION NanoGrout CFGLVDUHDG\WRXVHKLJKVWUHQJWKKLJKO\ÀRZDEOHQRQVKULQNFHPHQWLWLRXV


 JURXW,WUHTXLUHVRQO\DGGLWLRQRIZDWHUDWVLWH,WFRQVLVWVRISRUWODQGFHPHQWDQGVSHFLDO
 FKHPLFDOVIRUQRQVKULQNDJHSURSHUWLHVKLJKÀXLGLW\DQGUHWHQWLRQSURSHUWLHVRIWKHPL[
at low water cement ratio.

USES *URXWLQJRI
 ‡ 3RVWWHQVLRQHGFDEOHGXFWV
 ‡ 6RQLFWXEHVLQWKHFRQFUHWHSLOHV
 ‡ 5HSDLURIQRQPRYLQJFRQFUHWHFUDFNVE\LQMHFWLRQ
 ‡ 5RFNDQFKRUV
 ‡ 6KHHHWSLOHDQFKRUV
 ‡ 0LFURSLOHV

ADVANTAGES ‡ 5HDG\WRXVHRQO\UHTXLUHVDGGLWLRQRIZDWHU
 ‡ +LJKO\ÀRZDEOHDQGVXSHULRUÀRZUHWHQWLRQ
 ‡ 1RQVKULQNZLWKFRQWUROOHGH[SDQVLRQ
 ‡ +LJKVWUHQJWK
 ‡ 1REOHHGLQJDQGVHWWOHPHQW
 ‡ &KORULGHIUHHQRFRUURVLRQRIPHWDOOLFSDUWV

TYPICAL PROPERTIES at 25°C

PROPERTY TEST METHOD VALUE


Component - Single
Form - Powder
Colour - Grey
Fresh Wet Density BSEN 445 NJOWU
Flow (Marsh Cone)* BSEN 445 W/P 0.36 0.32
Initial 10-25 sec 10-25 sec
$IWHUPLQ < 25 sec < 25 sec
Compressive Strength BSEN 445 7 Days 40 N/mm² 50 N/mm²
28 Days 55 N/mm² 65 N/mm²
Flexural Strength BSEN 445 9 N/mm² at 28 days
Expansion BSEN 445 Upto 4% positive expansion
BSEN 934-4 Upto 4% positive expansion
Bleeding BSEN 934-4 < 2%
Chloride Content BSEN 480-10 Nil to BSEN 934-4
Sedimentation 5HSRUW1R < 2%
3URSHUWLHVZLWKWKHXVHRIKLJKVKHDUFROORLGDOJURXWPL[HU9DOXHVPD\FKDQJHZLWKWKHW\SHRIPL[HU

CC/NG03/Ver9/11/15 1/3 Technical Datasheet


Construction Chemicals

NanoGrout CFG

SURFACE PREPARATION For post-tension Cable Ducts:


 'XFWVWREHJURXWHGVKRXOGEHFOHDQHGEHIRUHWKHDSSOLFDWLRQRIJURXWDQGDQ\VWDQGLQJ
 ZDWHUPXVWEHUHPRYHG(QVXUHWKDWWKHFDVLQJGXFWLVOHDNSURRI&KHFNWKHDLUYHQWV
 DQGYDOYHVDUHLQJRRGZRUNLQJFRQGLWLRQ
For Concrete Repair:
 ,Q FDVH RI UHSDLULQJ RI FRQFUHWH FUDFNV DQG ¿OOLQJ LQWULFDWH YRLGV WKH SUHSDUHG DUHD
 VKRXOGEHVDWXUDWHGZLWKZDWHUIRUKUVSULRUWRWKHSODFHPHQWRINanoGrout CFG.
 $OOIUHHZDWHUVKRXOGEHUHPRYHGEHIRUHSODFLQJWKHJURXW

MIXING ,W LV UHFRPPHQGHG WR XVH PHFKDQLFDO KLJK VKHDU JURXW PL[HU DQG JURXW SXPS LQ
 RUGHU WR JHW RSWLPXP GLVSHUVLRQ DQG ÀXLGLW\ +RZHYHU IRU WKH VPDOOHU EDWFKHV GULOO
 PDFKLQHZLWKDSDGGOHFDQDOVREHXVHG0L[NJNanoGrout CFGZLWKPD[LPXP
 OLWHUVRISRWDEOHZDWHU$GGLQJPRUHZDWHUWKDQWKHVSHFL¿HGOLPLWVZLOOUHVXOWLQORVVRI
 XOWLPDWH SURSHUWLHV 0L[ NanoGrout CFG WR SUHPHDVXUHG ZDWHU DQG PL[ IRU  WR 
 PLQXWHV $OORZ D WLPH JDS RI  PLQXWHV DQG PL[ DJDLQ IRU  PLQXWHV WR JHW WKH
 GHVLUHGÀRZ8VHFKLOOHGZDWHUWRJHWEHWWHUÀRZDQGUHWHQWLRQSURSHUWLHV

APPLICATION For Cable Ducts:


 *URXWLQJSURFHVVVKRXOGVWDUWIURPRQHVLGHRIWKHFDEOHGXFWWLOOKRPRJHQRXVFRQVLVWHQF\
 RINanoGrout CFGÀRZVIURPFRQVHFXWLYHDLUYHQWYDOYHVDQGRXWOHWYDOYHV
For Sonic Tubes in Concrete Piles :
NanoGrout CFGVKRXOGEHSXPSHGLQVRQLFWXEHE\WUHPLHPHWKRG3XPSLQJRIJURXW
 VKRXOGEHFRQWLQXHGWLOOFRQVLVWHQWTXDOLW\RIJURXWRYHUÀRZVIURPVRQLFWXEH*URXWLQJ
 VKRXOG WDNH SODFH XVLQJ KHDY\ GXW\ JURXW PL[HU SXPS DQG ÀH[LEOH JURXWLQJ KRVH
 *URXWLQJVKRXOGEHGRQHZLWKFRQWLQXRXVÀRZ

CURING $OO H[SRVHG JURXW VXUIDFHV VKRXOG EH FXUHG E\ SRQGLQJ RI ZDWHU RU E\ XVLQJ ZHW
 KHVVDLQ$OWHUQDWLYHO\FXULQJFRPSRXQGIURPJetCureUDQJHFDQEHXVHG

NOTE NanoGrout CFGDOVRDYDLODEOHEDVHGRQQRQJDVHRXVH[SDQVLRQV\VWHP


 &RQVXOW&RQPL[IRUGHWDLOV

PACK SIZE NJDQGNJ

YIELD ,WUNJEDJZLWK:3UDWLR

GENERAL INFORMATION Shelf Life  PRQWKV IURP GDWH RI PDQXIDFWXUH ZKHQ VWRUHG XQGHU
   ZDUHKRXVHFRQGLWLRQVLQRULJLQDOXQRSHQHGSDFNLQJ
   ([WUHPHWHPSHUDWXUHKXPLGLW\PD\UHGXFHVKHOIOLIH
Cleaning &OHDQ DOO HTXLSPHQW DQG WRROV ZLWK ZDWHU LPPHGLDWHO\
   DIWHUXVH

CC/NG03/Ver9/11/15 2/3 Technical Datasheet


Construction Chemicals

NanoGrout CFG

HEALTH and SAFETY PPE’s *ORYHVJRJJOHVDQGVXLWDEOHPDVNPXVWEHZRUQ


Precautions &RQWDFWZLWKVNLQH\HVHWFPXVWEHDYRLGHG,IVZDOORZHG
   VHHNPHGLFDODWWHQWLRQLPPHGLDWHO\
Hazard 5HJDUGHGDVQRQKD]DUGRXVIRUWUDQVSRUWDWLRQ
Disposal 'R QRW UHXVH EDJV 7R EH GLVSRVHG RII DV SHU ORFDO UXOHV
   DQGUHJXODWLRQV
Additional lnformation  5HIHU06'6 $YDLODEOHRQUHTXHVW

TECHNICAL SERVICE CONMIX Technical Services DUH DYDLODEOH RQ UHTXHVW IRU RQVLWH VXSSRUW WR DVVLVW LQ
 WKHFRUUHFWXVHRILWVSURGXFWV

Manufacturer:
CONMIX LTD.
32%R[6KDUMDK
8QLWHG$UDE(PLUDWHV 6DOHV2I¿FH
7HO 7HO
)D[ )D[
(PDLOFRQPL[#FRQPL[FRP ZZZFRQPL[FRP

,WLVWKHFXVWRPHU¶VUHVSRQVLELOLW\WRVDWLVI\WKHPVHOYHVE\FKHFNLQJZLWKWKHFRPSDQ\ZKHWKHULQIRUPDWLRQLVVWLOOFXUUHQWDWWKHWLPHRIXVH7KHFXVWRPHUPXVWEHVDWLV¿HGWKDWWKHSURGXFW
LVVXLWDEOHIRUWKHXVHLQWHQGHG$OOSURGXFWVFRPSO\ZLWKWKHSURSHUWLHVVKRZQRQFXUUHQWGDWDVKHHWV+RZHYHU&RQPL[GRHVQRWZDUUDQWRUJXDUDQWHHWKHLQVWDOODWLRQRIWKHSURGXFWVDVLW
GRHVQRWKDYHDQ\FRQWURORYHULQVWDOODWLRQRUHQGXVHRIWKHSURGXFW$OOLQIRUPDWLRQDQGSDUWLFXODUO\WKHUHFRPPHQGDWLRQVUHODWLQJWRDSSOLFDWLRQDQGHQGXVHDUHJLYHQLQJRRGIDLWK7KH
SURGXFWVDUHJXDUDQWHHGDJDLQVWDQ\PDQXIDFWXULQJGHIHFWVDQGDUHVROGVXEMHFWWR&RQPL[VWDQGDUGWHUPVDQGFRQGLWLRQVRIVDOH

CC/NG03/Ver9/11/15 3/3 Technical Datasheet