BULLETIN
B-2011
®
www.versa-valves.com
e-mail: sales@versa-valves.com
Versa Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey 07601 ● TEL: 201/843-2400 Fax: 201/843-2931
Versa BV., Prins Willem Alexanderlaan 1429, 7312 GB Apeldoorn, The Netherlands ● TEL: +01131-55-3681900 FAX: +01131-55-3681909
• Pilot, Manual, and Mechanical Actuation
• Plunger travels only 3/16”
• Full 3/16” Flow Area
Versa exercises diligence to assure that
• All Brass Bodies and Stainless Steel Plunger
information contained in this catalog is correct, • Service: Pneumatic-vacuum to 200 psi. Two-way
but does not accept responsibility for any
errors or omissions. Versa also reserves the can be used for hydraulic pressures to 500 psi.
right to change or delete data or products at
any time without prior notification. To be sure
• Leakproof: Uses standard “O” ring seals;
the data you require is correct, consult factory. fluorocarbon and low temperature seals available
• High Cv; (Normally Closed: 0.6, Normally Open: 0.5)
• Available with 1/8” NPT Threaded Ports in Valve
Body or with Gasketed Ports for Subplate or
Manifold Mounting. (See page 7)
Note: All Series “B” valves utilize the basic design and parts of the button-operated types shown below.
Basic dimensions and parts lists shown on page 7. Those parts listed and dimensions shown for specific
valve types, are required in addition to or in place of the basic parts and dimensions shown on page 7.
Suffix Options:
—67 Stainless steel button —167 Body (and nuts where applicable),
—68 Mtg. holes clear #10 screw brass internals and aluminum button
—155 Fluorocarbon seals electroless nickel plated.
— 294B Rubber button cover —S Strong spring for applications with
Not Panel Mounting marginal lubrication.
Panel Mounting
Panel Mounting with
Rubber Button Cover
Suffix Options:
—67 Stainless steel button —167 Body (and nuts where applicable), brass internals
—68 Mtg. holes clear #10 screw and aluminum button electroless nickel plated.
—155 Fluorocarbon seals —S Strong spring for applications with marginal
Not Panel Mounting lubrication.
Panel Mounting
2
PALM BUTTON 113 DIA.
16 4302-65-125 KNOB (BLACK)
4302-65-125G KNOB (GREEN)
4302-65-125R KNOB (RED)
4302-65-125B KNOB BUTTON
37
16
PALM LEVER
1 NPT Port
8
5
116
7
116
5
216
2 1
48
118 10˚
1
Bracket and Palm Lever
is sub-assembly
BA-3200-69L
5
116
Suffix Options:
—67 Stainless steel button —167 Body (and nuts where applicable), brass internals
—68 Mtg. holes clear #10 screw and aluminum button electroless nickel plated.
—155 Fluorocarbon seals —S Strong spring for applications with marginal
lubrication.
HAND LEVER
P-1001-08 BALL
3209-24 HANDLE
25° 4302-19D GLAND SEAL
4
3209-23A BALL**
5 78
3209-18L LEVER CAP
P-1003-10 BALL
3209-25 BUTTON
**BALL SHOWN IS SPRING RETURN
TYPE - DETENT
TYPE IS 3209-23
Hand Lever sub-assembly is
BA-3200-69L
Hand Lever
Normally Closed Normally Open
(Spring Return)
TWO WAY BHS-2208 BHS-2206
THREE WAY BHS-3208 BHS-3206
Suffix Options:
—68 Mtg. holes clear #10 screw —S Strong spring for applications with marginal
—155 Fluorocarbon seals lubrication. Std on detented type.
—167 Body, brass internals, lever cap
are electroless nickel plated
BALL CAM 1
14 Ø P-1003-24 CAS BALL
3209-13 CAM CAP
213 3209-48 NUT
16
Suffix Options:
—68 Mtg. holes clear #10 screw —S Strong spring for applications with marginal
—155 Fluorocarbon seals lubrication.
—167 Body, brass internals, lever cap
are electroless nickel plated
CAM LEVER
3 TRAVEL
8
1
24
1 81
11
116
ø 87
Suffix Options:
—67 Stainless steel button —167 Body, brass internals, bracket and aluminum
—68 Mtg. holes clear #10 screw button are plated with electroless nickel.
—155 Fluorocarbon seals —S Strong spring for applications with marginal
lubrication.
Ball Cam
Normally Closed Normally Open
With Overtravel
TWO WAY BlK-2208-66-18 BlK-2206-66-18
THREE WAY BlK-3208-66-18 BlK-3206-66-18
Suffix Options:
—68 Mtg. holes clear #10 screw —S Strong spring for applications with marginal
—155 Fluorocarbon seals lubrication.
—167 Body, brass internals, cam cap
are electroless nickel plated.
TRIP-CAM LEVER 2¼ Ø 1
⅜ Travel
1⅛
3
1
PILOT
Controlled by a low-pressure signal applied to a small pilot
piston integrated into the valve. This actuates the valve. When the
pressure is exhausted, the valve returns to the unactuated position.
Pilot medium is separate from medium being controlled.
3 38 3209-48 Nut
Minimum Pilot
Pressure required 18 20 22 24 26 28 30 32 34 36
for Actuation (PSI)
If Inlet Pressure (PSI) is 0-20 40 60 80 100 120 140 160 180 200
Suffix Options:
— 67 Brass and stainless steel internals — 167 Body, brass internals, pilot cap are
— 68 Mtg. holes clear #10 screw electroless nickel plated.
—155 Fluorocarbon seals — S Strong spring for applications with marginal
lubrication. Increases pilot pressure by 45%.
BASIC VALVE
DIMENSIONS AND PARTS
NORMALLY CLOSED NORMALLY OPEN
Ø 1 14
* Maximum panel thickness is 7/16” except for valves without button guard. For theses, maximum panel thickness is 1/4”.
The warnings below must be read and reviewed before designing a system utilizing,
installing, servicing, or removing a Versa product. Improper use, installation or servicing of LIMITED WARRANTY DISCLAIMER
a Versa product could create a hazard to personnel and property. AND LIMITATION OF REMEDIES
DESIGN APPLICATION WARNINGS Versa’s Series products are warranted
Versa products are intended for use where compressed air or industrial hydraulic fluids are to be free from defective material and
present. For use with media other than specified or for non-industrial applications or other workmanship for a period of ten years
applications not within published specifications, consult Versa. from the date of manufacture, provided
Versa products are not inherently dangerous. They are only a component of a larger said products are used in accordance
system. The system in which a Versa product is used must include adequate safeguards with Versa specifications. Versa’s
to prevent injury or damage in the event of system or product failure, whether this failure liability pursuant to that warranty
be of switches, regulators, cylinders, valves or any other system component. System is limited to the replacement of the
designers must provide adequate warnings for each system in which a Versa product
is utilized. These warnings, including those set forth herein, should be provided by the Versa product proved to be defective
designer to those who will come in contact with the system. provided the allegedly defective
product is returned to Versa or its
Where questions exist regarding the applicability of a Versa product to a given use, inquiries authorized distributor. Versa provides
should be addressed directly to the manufacturer. Confirmation should be obtained directly
from the manufacturer regarding any questioned application prior to proceeding. no other warranties, expressed or
implied, except as stated above.
INSTALLATION, OPERATION AND SERVICE WARNINGS There are no implied warranties
Do not install or service any Versa product on a system or machine without first of merchantability or fitness for a
depressurizing the system and turning off any air, fluid, or electricity to the system or
machine. All applicable electrical, mechanical, and safety codes, as well as applicable particular purpose. Versa’s liability for
governmental regulations and laws must be complied with when installing or servicing a breach of warranty as herein stated is
Versa product. the only and exclusive remedy and in
no event shall Versa be responsible or
Versa products should only be installed or serviced by qualified, knowledgeable personnel
who understand how these specific products are to be installed and operated. The liable for incidental or consequential
individual must be familiar with the particular specifications, including specifications for damages.
temperature, pressure, lubrication, environment and filtration for the Versa product which
is being installed or serviced. Specifications may be obtained upon request directly from
Versa. If damages should occur to a Versa product, do not Operate the system containing
the Versa product. Consult Versa for technical information.