Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Ironclad Sensor Line Cable: Rbtec Inc. 7638 Standish Place Derwood MD 20855 Tel: (301) 760-4016 Fax: (301) 762-2253

Download as pdf or txt
Download as pdf or txt
You are on page 1of 2

RBtec Inc.

7638 Standish place Derwood MD 20855


Tel: (301) 760-4016 Fax: (301)762-2253
www.rbtec.com info@rbtec.com

IRONCLAD Sensor Line Cable

The Ironclad Sensor Line Cable is attached to the desired-to-protect structure


(fence/wall), converting the whole structure into a smart barrier, which will detect
any kind of intrusion.
The Ironclad Sensor Line Cable has a life expectancy of 10 years, is easy to install
and non-obstructive to the eye. This cable is attached directly to the fence without
any need for conduit with cable ties.
The sensor is totally passive and has different ranges of sensitivity that will allow
adapting it to any specific application.
The zone starts at the electronic processor (Analyzer) and ends at the MCT-End
of Line protection (EOL) module.

ALL RIGHTS RESERVED to RBtec Perimeter Security Systems


RBtec Inc.
7638 Standish place Derwood MD 20855
Tel: (301) 760-4016 Fax: (301)762-2253
www.rbtec.com info@rbtec.com

LPU-304 Processor
An electronic analyzer processor that continuously monitors the cable signal output and
detects any attempt to penetrate the perimeter.
The analyzer is designed to ignore signals generated by rain, wind or birds. It utilizes
highly advanced microprocessor technology in a microprocessor and is installed inside
an IP66/NEMA4X rated weatherproof Plastic/Metal box.
The analyzer scans the integrity of the sensor line, thus monitoring the terminal that
has been integrated to the cable. If the sensor cable is cut, damaged or interfered with
in any way, the analyzer will immediately detect and activate a warning signal.

SPECIFICATIONS:
Operating Power Requirements:
 12 – 24VDC 40mA @ 12VDC
Lightening Protection:
Enclosure:
 Gas Discharge Devices on all
 NEMA 4X, IP-66
Inputs/Outputs & Communication line.
 9.5 x 7.5 x 2.75” (24 x 19.5 x 7.0cm)
Alarm Inputs  Weight: 2.2 lbs (1Kg)
 2 Ironclad sensor cable inputs.
Environment:
 4 Intrusion and Line monitoring for
 Operating Temperature: - 40° to
accessories like magnets, contact,
221°F (-40° to 105°C)
microwaves and motion detectors.
 Relative Humidity up to 98% non-
 1 Tamper switch.
condensing.
Alarm Outputs
Sensor Cable & Accessories:
 Dry contact relays with N.O. and N.C.
 Maximum length per zone: 1000’
contacts rated 1A @ 12VDC.
(305m).
 4 solid state relays for accessories.
 Total length per controller 2000’
 1 Tamper switch relay.
(610m)
 Alarm output via RS-485 Protocol.
 UV resistant 2 conductor coaxial cable.
Alarm Indicators  Diameter: 0.196” (5mm)
 Power Status LED.  Color: Silver
 Alarm Relay Status LED.  UV resistant cable ties (610 per Zone)
 Tamper Indication LED.
Options:
Connector:  RS485: Intrudalert 6600 Protocol
 Dry contact connection Sensor Cable  VX-25: Weather Compensation Unit
Inputs for each zone.  Armored Conduit: Vandal Resistant

ALL RIGHTS RESERVED to RBtec Perimeter Security Systems

You might also like