Ironclad Sensor Line Cable: Rbtec Inc. 7638 Standish Place Derwood MD 20855 Tel: (301) 760-4016 Fax: (301) 762-2253
Ironclad Sensor Line Cable: Rbtec Inc. 7638 Standish Place Derwood MD 20855 Tel: (301) 760-4016 Fax: (301) 762-2253
Ironclad Sensor Line Cable: Rbtec Inc. 7638 Standish Place Derwood MD 20855 Tel: (301) 760-4016 Fax: (301) 762-2253
LPU-304 Processor
An electronic analyzer processor that continuously monitors the cable signal output and
detects any attempt to penetrate the perimeter.
The analyzer is designed to ignore signals generated by rain, wind or birds. It utilizes
highly advanced microprocessor technology in a microprocessor and is installed inside
an IP66/NEMA4X rated weatherproof Plastic/Metal box.
The analyzer scans the integrity of the sensor line, thus monitoring the terminal that
has been integrated to the cable. If the sensor cable is cut, damaged or interfered with
in any way, the analyzer will immediately detect and activate a warning signal.
SPECIFICATIONS:
Operating Power Requirements:
12 – 24VDC 40mA @ 12VDC
Lightening Protection:
Enclosure:
Gas Discharge Devices on all
NEMA 4X, IP-66
Inputs/Outputs & Communication line.
9.5 x 7.5 x 2.75” (24 x 19.5 x 7.0cm)
Alarm Inputs Weight: 2.2 lbs (1Kg)
2 Ironclad sensor cable inputs.
Environment:
4 Intrusion and Line monitoring for
Operating Temperature: - 40° to
accessories like magnets, contact,
221°F (-40° to 105°C)
microwaves and motion detectors.
Relative Humidity up to 98% non-
1 Tamper switch.
condensing.
Alarm Outputs
Sensor Cable & Accessories:
Dry contact relays with N.O. and N.C.
Maximum length per zone: 1000’
contacts rated 1A @ 12VDC.
(305m).
4 solid state relays for accessories.
Total length per controller 2000’
1 Tamper switch relay.
(610m)
Alarm output via RS-485 Protocol.
UV resistant 2 conductor coaxial cable.
Alarm Indicators Diameter: 0.196” (5mm)
Power Status LED. Color: Silver
Alarm Relay Status LED. UV resistant cable ties (610 per Zone)
Tamper Indication LED.
Options:
Connector: RS485: Intrudalert 6600 Protocol
Dry contact connection Sensor Cable VX-25: Weather Compensation Unit
Inputs for each zone. Armored Conduit: Vandal Resistant