400 Series Connect2 Medical Gas Outlets: Elements

Download as pdf or txt
Download as pdf or txt
You are on page 1of 4

Product Specification

400 Series Connect2® Medical Gas Outlets


Elements

• Accepts both Chemetron® and Ohmeda®


adapters in the same outlet
• Conforms to NFPA 99 and CGA
standards.
• Safety keyed to help prevent cross-connections
• Rough-in channel box protected by metal
plaster guard until final assembly
• Adjustable valve mechanism to compensate
for variations in plaster thicknesses up to 3/4"
• Cleaned for oxygen service
• UL listed and CSA approved

Description

The Allied Connect2® medical gas outlet stations The outlet stations are fully compliant with
provide convenient access to medical gases in NFPA 99 and CSA Z-305, and are cleaned for
patient care locations. They accept either a oxygen service in accordance with CGA G-4.1.
Chemetron or Ohmeda adapter in the same The outlet is UL listed.
outlet.
Release is easily accomplished with one hand
Finish plates are color-coded plastic with stainless using a push-button release (or twist release for
steel inserts. Outlet finish plates and rough-in Ohmeda style adapters). The primary valve
plates are safety keyed for positive cross- poppet provides a dust-proof seal. Vacuum
connection prevention. Primary valves are outlets maybe used with or without slide brackets
separate from the finish plate, allowing easy for vacuum collection bottles of up to 1/2-gallon
testing for leaks and cross connection. Primary capacity. (Where slide brackets are used, order
valves are made of brass and contain a self-sealing one per vacuum outlet.)
poppet. Primary valves are field adjustable to
compensate for variations in plaster thickness of
1/2" to 3/4". Outlets may be special ordered
with extended valve bodies that allow for an
additional 3/8" or 3/4" adjustment.

The type K copper inlet tube has a 1/2" OD


connection. The primary gas check can be
serviced without shutting off the gas supply.
400 Series Connect2 Medical Gas Outlets

Materials

Component Material
Valve Body Machined Brass
Viton Seal
Valve Block Brass Forging/Machined Brass
Type K or L Seamless Copper Tube
Viton Seal
Outlet Box 20 Gauge Steel
Cover Plate Plastic Color-Coded Fascia
Brushed Stainless Steel Inserts
Buffed Edge
Plastic Color-Coded Release Button

Ordering Information

Catalog Number Catalog Number


Gas Service Wide Faceplate Quantity Narrow Faceplate Quantity
(2.75") (2.25")
Oxygen 64-02-4001 64-02-4011

Vacuum 64-02-4002 64-02-4012

Air 64-02-4004 64-02-4014

Nitrous Oxide 64-02-4003 64-02-4013

Evacuation Vacuum 64-02-4008 64-02-4018

Carbon Dioxide 64-02-4005 64-02-4015

Slide Bracket 64-59-1212 64-59-1212

Product Specification
400 Series Connect2 Medical Gas Outlets

Dimensional Data

Refer to installation instructions prior to assembly.

Product Specification
400 Series Connect2 Medical Gas Outlets

Customer Service:
All specifications are nominal and subject to change USA: (800) 444-3960
without notice. FAX: (314) 771-7537 1720 Sublette Avenue
Canada/Mexico: (800) 446-0552 St. Louis, MO 63110 USA
Warranty: FAX: (800) 246-6201
See Allied Statement of Warranties for details. (314)771-2400
International: (314) 268-1683 www.alliedhpi.com
FAX: (314) 771-5183 ISO 9001 CERTIFIED
© 2006 Allied Healthcare Products, Inc.® Printed in USA

Product Specification
Form 64-00-0006 May 2006