Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
152 views

Reinforcement Check by IS Code

The document provides calculations for the reinforcement design of underground tunnel columns for the Mumbai Metro Line 3 project. It calculates the required reinforcement for two columns with different load capacities based on the axial load strength and bending moment capacity according to code specifications. It determines that both column designs are safe based on an interaction check of the applied and capacity moments.

Uploaded by

DEBASIS BARMAN
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
152 views

Reinforcement Check by IS Code

The document provides calculations for the reinforcement design of underground tunnel columns for the Mumbai Metro Line 3 project. It calculates the required reinforcement for two columns with different load capacities based on the axial load strength and bending moment capacity according to code specifications. It determines that both column designs are safe based on an interaction check of the applied and capacity moments.

Uploaded by

DEBASIS BARMAN
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 10

GEOCONSULT India Pvt Ltd APPENDIX -1A

A company of the GEOCONSULT group Job no: I6073


Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 3997 kN Mx 79.94 kN-m This moment is maxm.
Design M2 (major bending), Mux 175 kN-m My 133.23 kN-m Actual moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 175.0 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 133.2 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.052
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 196.625 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.291 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 0.77
Ley / B = 0.00 Mx Alpha, α 1.943
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.826


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx
GEOCONSULT India Pvt Ltd APPENDIX -1A
A company of the GEOCONSULT group Job no: I6073
Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 3600 kN Mx 72.00 kN-m This moment is maxm.
Design M2 (major bending), Mux 220 kN-m My 120.00 kN-m Actual moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 220.0 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 120.0 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.06
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 226.875 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.262 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 0.69
Ley / B = 0.00 Mx Alpha, α 1.817
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.976


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx
GEOCONSULT India Pvt Ltd APPENDIX -1A
A company of the GEOCONSULT group Job no: I6073
Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 3477 kN Mx 69.54 kN-m This moment is maxm.
Design M2 (major bending), Mux 37 kN-m My 115.90 kN-m This moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 69.5 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 115.9 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.06
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 226.875 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.253 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 0.67
Ley / B = 0.00 Mx Alpha, α 1.777
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.153


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx
GEOCONSULT India Pvt Ltd APPENDIX -1A
A company of the GEOCONSULT group Job no: I6073
Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 2870 kN Mx 57.40 kN-m This moment is maxm.
Design M2 (major bending), Mux 126 kN-m My 95.67 kN-m Actual moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 126.0 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 95.7 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.062
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 234.4375 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.209 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 0.55
Ley / B = 0.00 Mx Alpha, α 1.583
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.407


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx
GEOCONSULT India Pvt Ltd APPENDIX -1A
A company of the GEOCONSULT group Job no: I6073
Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 5271 kN Mx 105.42 kN-m This moment is maxm.
Design M2 (major bending), Mux 85 kN-m My 175.70 kN-m This moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 105.4 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 175.7 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.03
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 113.4375 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.383 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 1.01
Ley / B = 0.00 Mx Alpha, α 2.000
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.909


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx
GEOCONSULT India Pvt Ltd APPENDIX -1A
A company of the GEOCONSULT group Job no: I6073
Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 4368 kN Mx 87.36 kN-m This moment is maxm.
Design M2 (major bending), Mux 159 kN-m My 145.60 kN-m Actual moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 159.0 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 145.6 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.05
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 189.0625 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.318 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 0.84
Ley / B = 0.00 Mx Alpha, α 2.000
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.738


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx
GEOCONSULT India Pvt Ltd APPENDIX -1A
A company of the GEOCONSULT group Job no: I6073
Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 3303 kN Mx 66.06 kN-m This moment is maxm.
Design M2 (major bending), Mux 14 kN-m My 110.10 kN-m This moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 66.1 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 110.1 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.06
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 226.875 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.240 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 0.63
Ley / B = 0.00 Mx Alpha, α 1.722
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.151


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx
GEOCONSULT India Pvt Ltd APPENDIX -1A
A company of the GEOCONSULT group Job no: I6073
Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 2703 kN Mx 54.06 kN-m This moment is maxm.
Design M2 (major bending), Mux 98 kN-m My 90.10 kN-m Actual moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 98.0 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 90.1 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.062
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 234.4375 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.197 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 0.52
Ley / B = 0.00 Mx Alpha, α 1.530
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.297


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx
GEOCONSULT India Pvt Ltd APPENDIX -1A
A company of the GEOCONSULT group Job no: I6073
Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 3036 kN Mx 60.72 kN-m This moment is maxm.
Design M2 (major bending), Mux 13 kN-m My 101.20 kN-m This moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 60.7 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 101.2 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.06
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 226.875 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.221 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 0.58
Ley / B = 0.00 Mx Alpha, α 1.636
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.148


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx
GEOCONSULT India Pvt Ltd APPENDIX -1A
A company of the GEOCONSULT group Job no: I6073
Page No.: -

MUMBAI METRO LINE 3 CONTRACT UGC- 04


Project: Design and Construction of Underground Section including three Underground Stations at Siddhi Vinayak, Dadar and Shitladevi Temple
and Associated Tunnels

Calculation for DEFINITIVE SEGMENT LINING DESIGN-Check for reinforcement by IS code


Moment due to minimum eccentricity
Design Pu 2474 kN Mx 49.48 kN-m This moment is maxm.
Design M2 (major bending), Mux 90 kN-m My 82.47 kN-m Actual moment is maxm.
Design M3 (minor bending), Muy 0 kN-m
fy = 500 N/mm2 Mux to be used : 90.0 kN-m Referring interaction chart in SP-16 and
fck = 50 N/mm2 Muy to be used : 82.5 kN-m considering d'/D , p/fck , Pu/(fck * B * D );
Width of column, B 1000 mm Using bar diameter 12 mm Mux1 / (fck*B*D^2) = 0.06
Assumed reinforcement , p 0.47 % Cover to rft. 45 mm Mux1 = 226.875 kN-m
Depth of column, D 275 mm d' = 51 mm Similarly,
Unsupported length of ground 0 m d' / D = 0.185 For minor Muy1 / (fck*B^2*D) = 0.06
floor column, L direction
Unsupported length of other For major
0 m d' / B = 0.051 Muy1 = 825 kN-m
floor column, L direction
Ground floor where Mux1, Muy1 are maxm. moment
Choose column type column p/fck = 0.009
capacity for axial load Pu
Effective length of column, Lex 0 m Pu /(fck * B * D) = 0.180 Puz = 0.45*fck*Ac + 0.75*fy*Asc
Effective length of column, Ley 0 m y-axis Puz = 5217.4834 kN
Slenderness Ratio Pu / Puz = 0.47
Ley / B = 0.00 Mx Alpha, α 1.457
D Mux α Muy α
Lex / D =
Given column is short column
0.00
x-axis ( )+ ( ) ≤
Mux1 Muy1
1.0

Minimum Eccentricity 0.295


or 20 mm
E = (Lex or Ley)/500 +( B or D)/30 or 20mm whichever is maxm.
whichever Value <= 1. Hence, column is safe.
Ex = 9.17 is maximum B As required = 1015 mm2
My
Ey = 33.33 As provided = 1290 mm2

I6073 file:///conversion/tmp/scratch/491941820.xlsx