This document outlines specifications for a three-storey residential project. [1] It specifies materials for backfilling, concrete blocks, concrete works, reinforcing steel bars and electrical, plumbing, and painting works. [2] Concrete hollow blocks of varying thicknesses will be used for interior and exterior walls. [3] Finishing materials include floor and wall tiles, gypsum board ceilings, doors, windows, and terrace grills made of galvanized iron sheets and tubing.
This document outlines specifications for a three-storey residential project. [1] It specifies materials for backfilling, concrete blocks, concrete works, reinforcing steel bars and electrical, plumbing, and painting works. [2] Concrete hollow blocks of varying thicknesses will be used for interior and exterior walls. [3] Finishing materials include floor and wall tiles, gypsum board ceilings, doors, windows, and terrace grills made of galvanized iron sheets and tubing.
This document outlines specifications for a three-storey residential project. [1] It specifies materials for backfilling, concrete blocks, concrete works, reinforcing steel bars and electrical, plumbing, and painting works. [2] Concrete hollow blocks of varying thicknesses will be used for interior and exterior walls. [3] Finishing materials include floor and wall tiles, gypsum board ceilings, doors, windows, and terrace grills made of galvanized iron sheets and tubing.
This document outlines specifications for a three-storey residential project. [1] It specifies materials for backfilling, concrete blocks, concrete works, reinforcing steel bars and electrical, plumbing, and painting works. [2] Concrete hollow blocks of varying thicknesses will be used for interior and exterior walls. [3] Finishing materials include floor and wall tiles, gypsum board ceilings, doors, windows, and terrace grills made of galvanized iron sheets and tubing.
Download as DOCX, PDF, TXT or read online from Scribd
Download as docx, pdf, or txt
You are on page 1of 4
SPECIFICATIONS
PROJECT: (3) Three-storey Residential
CLIENT:
I. THE PROJECT SITE
II. MATERIAL SPECIFICATIONS
A. Backfilling Materials The backfilling materials should be free from garbage and other materials that can be tampered and already hardened before putting reinforcements and concrete on slabs. B. Concrete Masonry Units Concrete hollow blocks to be use shall be 4” x 8” x 16” and the shape should be the stretcher using 1:3 cement and sand ratio proportion to the exterior walls of the proposed residential. The walls should be strong and reinforced by 10mm rebars, horizontal and vertical reinforcements so to that can repel calamities like earthquakes and strong water current if flood occurs in the near future. For the interior walls, the concrete hollow blocks to be used shall be 4” thk using the same cement and sand ratio for mortar filler, and 5” for exterior walls. C. Concrete Works The cement to be used shall be Portland cement or any approved type of cement. It should be in good quality and stored at room temperature free from moisture so that it will not be hard. D. Reinforcing Steel Bars All reinforcing steel bars shall be deformed with a minimum yield strength; Fy = 275 MPa less than 16mm bar Fy = 414 MPa more than 16mm bar All reinforcing bar must be clean from rust, grease and other materials which tend to impair bond. All reinforcing steel bars shall be accurately and securely placed before pouring concrete or applying mortar or grout. Concrete slab thickness shall be 4” spaced 300mm on center bothways. III. FINISHES A. Floor and Wall Tiles Floor tiles shall be 60 x 60 Arte floor tiles will be used for living, bedroom, dining, and bathroom and except for kitchen counter top. At all toilets and bath floor used 60cm x 60 cm (arte tiles) non-skid homogenous floor tiles and floor ceiling 60 x 60 cm tiles, while at kitchen and lavatory counter top, use black Granalitic tiles. B. Ceiling Finishes 9mm thick Gypsum board should be used for all ceiling surfaces and other approved brand and supplier. It should be framed with 1 x 2” metal furrings riveted and screwed. C. Doors and Windows Panel door is installed at main entrance of the proposed residential. Prefabricated doors for bedrooms and CR using tanguile and marine plywood with 0.80m x 2.10m for bedrooms and 0.70m x 2.10m for CR. PVC windows shall be used with 3/16” glass. D. Doorknobs and Lockets Shall be Yale brand or quickset brand or any approved brands made of good quality should be used to ensure safety. Doorknobs color will be aluminum or brass type color. E. Terrace grills and Railings Shall be made of GI sheets, ¾“ flat bars, square bars, 1” tubular and 2 x 4 tubular. IV. ROOFING A. Roofing Materials Use rib type roofing prepainted with gutted on the top roof. Second floor roof, use existing tegula with corrugated sheet roofing in 2 x 3 C- purlins with angular bar connector. B. Roof Framing Shall be use 2 x 2 x 3/16” thick MS-plate for steel connections. Sag rods and turn buckles should be used accordingly to roof framing plans. All steel materials to be used shall be painted with red oxide or lead red primer and must be free from rust to ensure the durability of steel before installation. All top chord and bottom chord to be used shall be 2 x 2 x 3/16 thick while members should be 1 ½ x 1 ½ x 1/4 “ thick angular steel. C-purlins 2 x 3 will be used and will be supported by 2 x 2 x 3/16” thick angular connectors welded with purlins. Spacing shall be 0.60m on center bothways. V. ELECTRICAL MATERIALS AND INSTALLATION A. Moldflex UPVC corrugated Flexible Electrical Conduit use ½” O and ¾” O moldflex for flexible electrical conduit for the proposed residential. Moldflex gives guaranteed protection for the electrical wiring system. It is flexible and lightweight for fast, easy and trouble free installation and it virtually eliminates the use of couplings, elbows so it is more economical. B. Switches – Use National or Toshiba brand or MCS brand for 2 x 4 switches, one gang, two gang and three gang if it is possible of three gang. C. Convenience Outlet – Use National or Universal brand for Duplex convenience outlets, range outlets, refrigerator outlets and also weather proof outlets. D. Junction box – Use 4 x 4 junction box with cover, orange color and made of plastic. E. Electrical Wires – Min. size to be used shall be 3.5mm^2 THW and the biggest shall be 8.0mm^2 THW F. Down lights/Pin lights – Use 5 watts and 13 watts pin lights, SL – 2000 without housing by Philips and or other approved products as indicated on plans. G. Panel board – Verify schematic riser diagram for the number of circuit braekers to be used. H. Circuit breakers – Min. size of breakers to be used shall be 20AT/50AF, while the biggest shall be 60AT/50AF. I. Light bulbs – 32 watts, SL-2000 light bulbs shall be used for toilets and baths areas. VI. PLUMBING FIXTURES AND ACCESSORIES A. Sanitary Sewer Line – Use 4” sewer pipe and 2” sewer branches. The brand of materials to be used shall be moldflex of neltex or any approved brand and pipe installation shall maintain at least 1% slope as required by the plumbing code of the Philippines. B. Hot and Cold water lines – Use ¾” pipe and ½” pipe PPR German pipes for hot. C. Sanitary Storm Drainage – Use 4 UPVC sewer pipe for sanitary storm drainage. VII. PAINTIN|G WORKS A. Use Boysen or any approved brand. B. After applying the first coat, let it dry for 24 hours before applying the second coat. C. The surfaces must be free from dirt and dust before the application of the paint.