FLASH MIXER

Flow Rate 355.00 M3/hr


Retention Time 0.75 Min
Volume 7.89 M3
HT 1.50 M
LxW 5.26 M2
Length 2.29 M
Width 2.29 M
Watts/min 225.00 Watts
Total Watts 1775.00 Watts
KW 1.78 KW
HP 2.38 HP
DOSHI ION EXCHANGE & CHEMICAL INDUSTRIES LTD.

PROJECT
CONSULTANT
EPC
SCHEME
DATE

Sludge Calculation

Clarifocculator MAIN PLANT

Alum ppm 50 ppm


Alum load 426 kg
lime ppm 20 ppm
lime load 436.8 kg
PE PPM 0.5 ppm
PE load 10.92 kg
Total 873.72 kg

Inlet 200.00 mg/l (ppm)


Flow 355.00 M3/HR
Inlet SS Load 71.00 KG/HR
Out Let 20.00 mg/l (ppm)
Out Let SS 180.00 mg/l (ppm)
Out let SS Load 63.90 KG/HR
Op. Hours 24.00 HR
Total Sludge Load 2407.32 KG/DAY
Sludge Consistancy 2.00%
Density 20.00 KG/M3
Sludge Volume Outlet 120.37 M3/DAY
Flow Inlet 8520.00 M3/DAY
Clarifier Volume Outlet 8399.63 M3/DAY
Clarifier Volume Outlet 350 M3/hr
TOTAL FLOW
Design Flocculator & Clarifier & Sludge Thickner

Flocculator

Flow Rate 355.00 M3/HR


(20-30 Min for
Conventional & 15 min
Retention time 20.00 Min for Reactive)
Volume 118.33 M3
Side Water Depth 2.20 M Normally
Surface area 53.79 M2 A

Flocculator Dia 8.27 M

Clarifier

Surface Loading Velocity 40.00 M3/m2/day (35 to 40)


Surface area 213.00 M2 B

Total Suface Area 266.79 A+B

Clarifier Retention Time 2.50 Hrs, Normally 2.5


Volume 887.50 M3
Side Wall Depth 4.17 M (Normally 3.5 to 3.75)

Total Side wall Depth 3.33

Diameter (With Clarifier) 18.44 M

Wear Load (<300) 147.18 M3/Day.m

Flocculator dia 8.28