TEST REPORT Number: GZHT90793132

Applicant: ZHEJIANG LEIMA SHOES IND. CO., LTD. Date: May 12, 2018
NO.188 JIXIAN ROAD,
ECONOMIC DEVELOPMENT ZONE,
RUIAN CITY, ZHEJIANG, CHINA
Attn: ROLLA

Sample Description:
Two (2) groups of submitted samples said to be:
(A) Three and a half (3.5) pairs of PU/Rubber Injection lace up safety ankle boots in Brown, Style: Durango(804-
4113)
(B) Two (2) pieces of Brown first layer of smooth leather used for Upper.
Standard : EN ISO 20345:2011
ASTM F2413-17
Size : EUR 42 (US 9)
Buyer : Bata
Referring Style : Snow, Snow Antiacido
Customer P.O. No. : Chile: 66782, 66786
Date Received/Date Test Started: May 07, 2018
Date Final Information Confirmed: --

Test Result Please Refer To Attached Page(S).

Should you have any query on this report, you may contact at gzfootwear@intertek.com

Authorized By:
For Intertek Testing Services Shenzhen Ltd.
Guangzhou Branch

Huang Ning, Andy


Assistant General Manager

Page 1 Of 6
*GZHT90793132*
lz / nicoleho
Intertek Testing Services Shenzhen Ltd, Guangzhou Branch
深圳天祥质量技术服务有限公司广州分公司
Room 02, 1-8/F. & Room 01, E101/E201/E301/E401/E501/E601/E701/E801, 3/F., Hengyun Building, 235 Kaifa Ave., Guangzhou
No.7-2, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, Guangdong, China Economic & Technological Development District, Guangzhou,
广州经济技术开发区科学城彩频路 7 号之二第 1-8 层 02 房、01 房 101、 China
E201、E301、E401、E501、E601、E701、E801 中国广州经济技开发区开发大道 235 号恒运大厦 3 楼
Tel: +86 208213 9001 Fax: +86 20 82089909 Postcode: 510663 Tel: +86 20 83966868 Fax: +86 20 82228169 Postcode: 510730
TEST REPORT Number: GZHT90793132
Tests Conducted (As Requested By The Applicant)

1 Upper/Outsole Bond Strength (Whole Footwear) (EN ISO 20344:2011(5.2))

Sample Size Result Requirement Pass/Fail


(A) 42 5.8 N/mm * Pass

Remark: *= Min. 4.0 N/mm, If The Sole Was Torn, Min. 3.0 N/mm

Expended Uncertainty: 0.10 N/mm, With k= 2 At 95% Confidence Level.

2 Impact Resistance Of Safety Footwear (EN ISO 20344:2011(5.4))

Test Condition:
Mass Of Striker: (20±0.2) kg
Impact Energy: (200±4) J

Sample Size Results Requirement Pass/Fail


(A) 42 Left 16.0 mm Min. 14.0 mm (#) Pass
Right 16.0 mm Min. 14.0 mm (#) Pass

Remark: #= In Addition, The Toecap Shall Not Develop Any Cracks Which Go Through The Material,
i.e. Through Which Light Can Be Seen.

Expanded Uncertainty: 0.36(Urel), With k=1.96 At 95% Confidence Level.

3 Compression Resistance Of Safety Footwear (EN ISO 20344:2011(5.5))

Test Condition:
Compression Speed: (5±2) mm/min
Load: (15±0.1) kN

Sample Size Results Requirement Pass/Fail


(A) 42 Left 18.0 mm Min. 14.0 mm Pass
Right 17.0 mm Min. 14.0 mm Pass

Expended Uncertainty: 0.13 mm, With k= 1.96 At 95% Confidence Level.

/ nicoleho Page 2 Of 6
Intertek Testing Services Shenzhen Ltd, Guangzhou Branch
深圳天祥质量技术服务有限公司广州分公司
Room 02, 1-8/F. & Room 01, E101/E201/E301/E401/E501/E601/E701/E801, 3/F., Hengyun Building, 235 Kaifa Ave., Guangzhou
No.7-2, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, Guangdong, China Economic & Technological Development District, Guangzhou,
广州经济技术开发区科学城彩频路 7 号之二第 1-8 层 02 房、01 房 101、 China
E201、E301、E401、E501、E601、E701、E801 中国广州经济技开发区开发大道 235 号恒运大厦 3 楼
Tel: +86 208213 9001 Fax: +86 20 82089909 Postcode: 510663 Tel: +86 20 83966868 Fax: +86 20 82228169 Postcode: 510730
TEST REPORT Number: GZHT90793132
Tests Conducted (As Requested By The Applicant)

4 Electric Hazard Resistance Footwear (ASTM F2412-11, 9)

ASTM F2413
(A) Leakage Current Pass/Fail
Requirement
Left: 0.42 mA * Pass
Left: 0.32 mA * Pass
Right: 0.37 mA * Pass

Remark: *= No Current Flow Or Leakage Current In Excess Of 1.0 mA Under The Application Of 18 000 V
At 60 Hz AC For 1 Minute.

5 Penetration Resistance (Whole Footwear With Non-metallic Anti-Penetration Insert)(EN ISO 20344:2011(5.8.3))

Sample Size Results Requirement Pass/Fail


The Tip Of The Test Nail Did
(A) 42 Left Not Penetrate Through The Min. 1100 N (*) Pass
Test Piece Before 1100 N
The Tip Of The Test Nail Did
Right Not Penetrate Through The Min. 1100 N (*) Pass
Test Piece Before 1100 N

Remark: *= The Tip Of The Test Nail Shall Not Penetrate Through The Test Piece.

6 Tear Strength (Upper) (EN ISO 20344:2011(6.3), ISO 3377-2:2002)

Sample Size Result Requirement Pass/Fail


(A) 42 Mean Value 192.5 N Min. 120 N Pass

Expanded Uncertainty: 2.77 N, With k= 2.06 At 95% Confidence Level.

/ nicoleho Page 3 Of 6
Intertek Testing Services Shenzhen Ltd, Guangzhou Branch
深圳天祥质量技术服务有限公司广州分公司
Room 02, 1-8/F. & Room 01, E101/E201/E301/E401/E501/E601/E701/E801, 3/F., Hengyun Building, 235 Kaifa Ave., Guangzhou
No.7-2, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, Guangdong, China Economic & Technological Development District, Guangzhou,
广州经济技术开发区科学城彩频路 7 号之二第 1-8 层 02 房、01 房 101、 China
E201、E301、E401、E501、E601、E701、E801 中国广州经济技开发区开发大道 235 号恒运大厦 3 楼
Tel: +86 208213 9001 Fax: +86 20 82089909 Postcode: 510663 Tel: +86 20 83966868 Fax: +86 20 82228169 Postcode: 510730
TEST REPORT Number: GZHT90793132
Tests Conducted (As Requested By The Applicant)

7 Tear Strength (Outsole) (EN ISO 20344:2011(8.2), ISO 34-1:2010, Method A)

Sample Size Density Result Requirement Pass/Fail


(A) 42 1.2 g/cm3 9.3 kN/m * Pass

Remark: *= Density: > 0.9 g/cm3, Min. 8 kN/m

Expanded Uncertainty: 0.32 kN/m, With k= 2.26 At 95% Confidence Level.

8 Abrasion Resistance (Outsole) (EN ISO 20344:2011(8.3), ISO 4649:2010, Method A)

Sample Size Density Result Requirement Pass/Fail


(A) 42 1.2 g/cm3 Relative Volume Loss: 103.1 mm3 * Pass

Remark: *= Density: > 0.9 g/cm3, Max. 150 mm3

Expanded Uncertainty: 1.76 mm3, With k= 1.96 At 95% Confidence Level.

9 Rigidity Test (Outsole) (EN ISO 20344:2011(8.4))

Sample Size Result


(A) 42 30°

Conclusion: There's No Need To Be Performed The Flexing Test.

NOTE Footwear Whose Angle Under The Applied Force Is Lower Than 45°From The Horizontal Is Not
Subjected To The Flexing Test.

/ nicoleho Page 4 Of 6
Intertek Testing Services Shenzhen Ltd, Guangzhou Branch
深圳天祥质量技术服务有限公司广州分公司
Room 02, 1-8/F. & Room 01, E101/E201/E301/E401/E501/E601/E701/E801, 3/F., Hengyun Building, 235 Kaifa Ave., Guangzhou
No.7-2, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, Guangdong, China Economic & Technological Development District, Guangzhou,
广州经济技术开发区科学城彩频路 7 号之二第 1-8 层 02 房、01 房 101、 China
E201、E301、E401、E501、E601、E701、E801 中国广州经济技开发区开发大道 235 号恒运大厦 3 楼
Tel: +86 208213 9001 Fax: +86 20 82089909 Postcode: 510663 Tel: +86 20 83966868 Fax: +86 20 82228169 Postcode: 510730
TEST REPORT Number: GZHT90793132
Tests Conducted (As Requested By The Applicant)

10 Resistance To Fuel Oil (Outsole) (EN ISO 20344:2011(8.6.1), ISO 1817:2011(8.3), EN ISO 868:2003)

Sample Size Result Requirement Pass/Fail


(A) 42 Change In Volume: +5.61% Max. +12%(*) Pass

Remark: *= If The Test Piece Shrinks By More Than 1% In Volume Or Increase In Hardness By
More Than 10 Shore A Hardness Units, Then A Further Flex Test Shall Be Performed In
Accordance With The Method Described In EN ISO 20344:2011, 8.6.2.
(+) Means Increase And (-) Means Shrinkage.

Expended Uncertainty: 0.16%, With k= 2.13 At 95% Confidence Level.

11 pH Value

As Per EN ISO 20344:2011, 6.9, With Reference To ISO 4045:2008, pH Value Was Measured By pH Meter.

Result Difference Figure Requirement


4.05 - *

Remark: *= Min. 3.20, If The pH Value Is Below 4.00, The Difference Figure Shall Be Less Than 0.70

Tested Component: Dark Brown Synthetic Material With Brown Leather Backing (Sample B)

Conclusion:
Standard Result
EN ISO 20345:2011 For pH Value Pass
This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a
recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than
the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing
Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save
as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any
liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our
gross negligence or wilful misconduct.

/ nicoleho Page 5 Of 6
Intertek Testing Services Shenzhen Ltd, Guangzhou Branch
深圳天祥质量技术服务有限公司广州分公司
Room 02, 1-8/F. & Room 01, E101/E201/E301/E401/E501/E601/E701/E801, 3/F., Hengyun Building, 235 Kaifa Ave., Guangzhou
No.7-2, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, Guangdong, China Economic & Technological Development District, Guangzhou,
广州经济技术开发区科学城彩频路 7 号之二第 1-8 层 02 房、01 房 101、 China
E201、E301、E401、E501、E601、E701、E801 中国广州经济技开发区开发大道 235 号恒运大厦 3 楼
Tel: +86 208213 9001 Fax: +86 20 82089909 Postcode: 510663 Tel: +86 20 83966868 Fax: +86 20 82228169 Postcode: 510730
TEST REPORT Number: GZHT90793132
Tests Conducted (As Requested By The Applicant)

GZHT90793132

/ nicoleho Page 6 Of 6
Intertek Testing Services Shenzhen Ltd, Guangzhou Branch
深圳天祥质量技术服务有限公司广州分公司
Room 02, 1-8/F. & Room 01, E101/E201/E301/E401/E501/E601/E701/E801, 3/F., Hengyun Building, 235 Kaifa Ave., Guangzhou
No.7-2, Caipin Road, Guangzhou Science City, GETDD, Guangzhou, Guangdong, China Economic & Technological Development District, Guangzhou,
广州经济技术开发区科学城彩频路 7 号之二第 1-8 层 02 房、01 房 101、 China
E201、E301、E401、E501、E601、E701、E801 中国广州经济技开发区开发大道 235 号恒运大厦 3 楼
Tel: +86 208213 9001 Fax: +86 20 82089909 Postcode: 510663 Tel: +86 20 83966868 Fax: +86 20 82228169 Postcode: 510730

You might also like