Safety Data Sheet

SECTION 1 PRODUCT AND COMPANY IDENTIFICATION

Rando HDZ 46
Product Use: Hydraulic Oil
Product Number(s): 219302, 254610, 273261
Synonyms: Rando HDZ 46 ISOCLEAN Certified
Company Identification
Productos Chevron México S. de R.L. de C.V.
Oriente 171 Núm. 401
Col. San Juan de Aragón Ampliación
Delegación Gustavo A. Madero C.P. 07470
Mexico

Transportation Emergency Response


CHEMTREC: (800) 424-9300 or (703) 527-3887
Mexico - SETIQ: 01 800 00 214 00 y 55 59 15 88 (D.F.)
Health Emergency
Chevron Emergency & Information Center: Located in the USA. International collect calls accepted. (800) 231-
0623 or (510) 231-0623
Product Information
email : ordenesmexico@chevron.com
SDS Requests: 01 (800) 711-8772

SECTION 2 HAZARDS IDENTIFICATION

CLASSIFICATION: Not classified as hazardous according to NOM-018-STPS-2015.

SECTION 3 COMPOSITION/ INFORMATION ON INGREDIENTS

COMPONENTS CAS NUMBER AMOUNT


Highly refined mineral oil (C15 - C50) Mixture 70 - 99 %weight

SECTION 4 FIRST AID MEASURES

Eye: No specific first aid measures are required. As a precaution, remove contact lenses, if worn, and flush eyes
with water.
Skin: No specific first aid measures are required. As a precaution, remove clothing and shoes if contaminated.
To remove the material from skin, use soap and water. Discard contaminated clothing and shoes or thoroughly

_____________________________________________________________________
Revision Number: 0 1 of 6 Rando HDZ 46
Revision Date: November 15, 2019 SDS : 51575
clean before reuse.
Ingestion: No specific first aid measures are required. Do not induce vomiting. As a precaution, get medical
advice.
Inhalation: No specific first aid measures are required. If exposed to excessive levels of material in the air, move
the exposed person to fresh air. Get medical attention if coughing or respiratory discomfort occurs.
Note to Physicians: In an accident involving high-pressure equipment, this product may be injected under the skin.
Such an accident may result in a small, sometimes bloodless, puncture wound. However, because of its driving
force, material injected into a fingertip can be deposited into the palm of the hand. Within 24 hours, there is
usually a great deal of swelling, discoloration, and intense throbbing pain. Immediate treatment at a surgical
emergency center is recommended.

SECTION 5 FIRE FIGHTING MEASURES

EXTINGUISHING MEDIA: Use water fog, foam, dry chemical or carbon dioxide (CO2) to extinguish flames.
Unusual Fire Hazards: Leaks/ruptures in high pressure system using materials of this type can create a fire hazard
when in the vicinity of ignition sources (eg. open flame, pilot lights, sparks, or electric arcs).

PROTECTION OF FIRE FIGHTERS:


Fire Fighting Instructions: This material will burn although it is not easily ignited. See Section 7 for proper
handling and storage. For fires involving this material, do not enter any enclosed or confined fire space without
proper protective equipment, including self-contained breathing apparatus.
Combustion Products: Highly dependent on combustion conditions. A complex mixture of airborne solids,
liquids, and gases including carbon monoxide, carbon dioxide, and unidentified organic compounds will be evolved
when this material undergoes combustion.

SECTION 6 ACCIDENTAL RELEASE MEASURES

Protective Measures: Eliminate all sources of ignition in vicinity of spilled material.


Spill Management: Stop the source of the release if you can do it without risk. Contain release to prevent
further contamination of soil, surface water or groundwater. Clean up spill as soon as possible, observing
precautions in Exposure Controls/Personal Protection. Use appropriate techniques such as applying non-
combustible absorbent materials or pumping. Where feasible and appropriate, remove contaminated soil. Place
contaminated materials in disposable containers and dispose of in a manner consistent with applicable regulations.
Reporting: Report spills to local authorities as appropriate or required.

SECTION 7 HANDLING AND STORAGE

General Handling Information: Avoid contaminating soil or releasing this material into sewage and drainage
systems and bodies of water.
Precautionary Measures: DO NOT USE IN HIGH PRESSURE SYSTEMS in the vicinity of flames, sparks and
hot surfaces. Use only in well ventilated areas. Keep container closed.
Static Hazard: Electrostatic charge may accumulate and create a hazardous condition when handling this material.
To minimize this hazard, bonding and grounding may be necessary but may not, by themselves, be sufficient.
Review all operations which have the potential of generating and accumulating an electrostatic charge and/or a
flammable atmosphere (including tank and container filling, splash filling, tank cleaning, sampling, gauging, switch
loading, filtering, mixing, agitation, and vacuum truck operations) and use appropriate mitigating procedures.
Container Warnings: Container is not designed to contain pressure. Do not use pressure to empty container or it
may rupture with explosive force. Empty containers retain product residue (solid, liquid, and/or vapor) and can be
dangerous. Do not pressurize, cut, weld, braze, solder, drill, grind, or expose such containers to heat, flame, sparks,
static electricity, or other sources of ignition. They may explode and cause injury or death. Empty containers
should be completely drained, properly closed, and promptly returned to a drum reconditioner or disposed of
properly.

_____________________________________________________________________
Revision Number: 0 2 of 6 Rando HDZ 46
Revision Date: November 15, 2019 SDS : 51575
SECTION 8 EXPOSURE CONTROLS/PERSONAL PROTECTION

GENERAL CONSIDERATIONS:
Consider the potential hazards of this material (see Section 2), applicable exposure limits, job activities, and other
substances in the work place when designing engineering controls and selecting personal protective equipment. If
engineering controls or work practices are not adequate to prevent exposure to harmful levels of this material, the
personal protective equipment listed below is recommended. The user should read and understand all instructions
and limitations supplied with the equipment since protection is usually provided for a limited time or under certain
circumstances.

ENGINEERING CONTROLS:
Use in a well-ventilated area.

PERSONAL PROTECTIVE EQUIPMENT


Eye/Face Protection: No special eye protection is normally required. Where splashing is possible, wear safety
glasses with side shields as a good safety practice.
Skin Protection: No special protective clothing is normally required. Where splashing is possible, select
protective clothing depending on operations conducted, physical requirements and other substances in the
workplace. Suggested materials for protective gloves include: Nitrile Rubber.
Respiratory Protection: No respiratory protection is normally required. If user operations generate an oil mist,
determine if airborne concentrations are below the occupational exposure limit for mineral oil mist. If not, wear an
approved respirator that provides adequate protection from the measured concentrations of this material. For air-
purifying respirators use a particulate cartridge.
Use a positive pressure air-supplying respirator in circumstances where air-purifying respirators may not provide
adequate protection.

Occupational Exposure Limits:

Component Country/ Form TWA STEL Ceiling Notation


Agency
Highly refined mineral oil ACGIH -- 5 mg/m3 10 mg/m3 -- --
(C15 - C50)
Highly refined mineral oil Mexico -- 5 mg/m3 10 mg/m3 -- --
(C15 - C50)
Consult local authorities for appropriate values.

SECTION 9 PHYSICAL AND CHEMICAL PROPERTIES

Attention: the data below are typical values and do not constitute a specification.

Appearance
Color: Light to Brown
Physical State: Liquid
Odor: Petroleum odor
Odor Threshold: No data available
pH: No data available
Melting Point: No data available
Freezing Point: No data available
Boiling Point: No data available
Flashpoint: (Cleveland Open Cup) 185 °C (365 °F) (Minimum)
Flammability (solid, gas): Not Applicable
Flammability (Explosive) Limits (% by volume in air):
Lower: No data available Upper: No data available
Vapor Pressure: No data available
Vapor Density (Air = 1): No data available
_____________________________________________________________________
Revision Number: 0 3 of 6 Rando HDZ 46
Revision Date: November 15, 2019 SDS : 51575
Density: 0.8671 kg/l @ 15°C (59°F) (Typical)
Solubility: Soluble in hydrocarbons; insoluble in water
Partition coefficient: n-octanol/water: No data available
Auto-ignition temperature: No data available
Decomposition temperature: No data available
Viscosity: 46 mm2/s @ 40°C (104°F) (Minimum)
Evaporation Rate: No data available

SECTION 10 STABILITY AND REACTIVITY

Reactivity: May react with strong acids or strong oxidizing agents, such as chlorates, nitrates, peroxides, etc.
Chemical Stability: This material is considered stable under normal ambient and anticipated storage and
handling conditions of temperature and pressure.
Hazardous Polymerization: Hazardous polymerization will not occur.
Incompatibility With Other Materials: Not applicable
Hazardous Decomposition Products: None known (None expected)

SECTION 11 TOXICOLOGICAL INFORMATION

IMMEDIATE HEALTH EFFECTS


Eye: Not expected to cause prolonged or significant eye irritation.
Eye Irritation: The eye irritation hazard is based on evaluation of data for product components.

Skin: High-Pressure Equipment Information: Accidental high-velocity injection under the skin of materials of this
type may result in serious injury. Seek medical attention at once should an accident like this occur. The initial
wound at the injection site may not appear to be serious at first; but, if left untreated, could result in disfigurement or
amputation of the affected part.
Contact with the skin is not expected to cause prolonged or significant irritation. Contact with the skin is not
expected to cause an allergic skin response. Not expected to be harmful to internal organs if absorbed through the
skin.
Acute Dermal Toxicity: The acute dermal toxicity hazard is based on evaluation of data for product components.
Skin Irritation: The skin irritation hazard is based on evaluation of data for product components.
Skin Sensitization: The skin sensitization hazard is based on evaluation of data for product components.

Ingestion: Not expected to be harmful if swallowed.


Acute Oral Toxicity: The acute oral toxicity hazard is based on evaluation of data for product components.

Inhalation: Not expected to be harmful if inhaled. Contains a petroleum-based mineral oil. May cause
respiratory irritation or other pulmonary effects following prolonged or repeated inhalation of oil mist at airborne
levels above the recommended mineral oil mist exposure limit. Symptoms of respiratory irritation may include
coughing and difficulty breathing.
Acute Inhalation Toxicity: The acute inhalation toxicity hazard is based on evaluation of data for product
components.

Acute Toxicity Estimate: Not Determined

ADDITIONAL TOXICOLOGY INFORMATION:


This product contains petroleum base oils which may be refined by various processes including severe solvent
extraction, severe hydrocracking, or severe hydrotreating. None of the oils requires a cancer warning under the
OSHA Hazard Communication Standard (29 CFR 1910.1200). These oils have not been listed in the National
_____________________________________________________________________
Revision Number: 0 4 of 6 Rando HDZ 46
Revision Date: November 15, 2019 SDS : 51575
Toxicology Program (NTP) Annual Report nor have they been classified by the International Agency for Research
on Cancer (IARC) as; carcinogenic to humans (Group 1), probably carcinogenic to humans (Group 2A), or possibly
carcinogenic to humans (Group 2B).
These oils have not been classified by the American Conference of Governmental Industrial Hygienists (ACGIH)
as: confirmed human carcinogen (A1), suspected human carcinogen (A2), or confirmed animal carcinogen with
unknown relevance to humans (A3).

SECTION 12 ECOLOGICAL INFORMATION

ECOTOXICITY
This material is not expected to be harmful to aquatic organisms.
The product has not been tested. The statement has been derived from the properties of the individual components.

MOBILITY
No data available.

PERSISTENCE AND DEGRADABILITY


This material is not expected to be readily biodegradable. The biodegradability of this material is based on an
evaluation of data for the components or a similar material.
The product has not been tested. The statement has been derived from the properties of the individual components.

POTENTIAL TO BIOACCUMULATE
Bioconcentration Factor: No data available.
Octanol/Water Partition Coefficient: No data available

SECTION 13 DISPOSAL CONSIDERATIONS

Use material for its intended purpose or recycle if possible. Oil collection services are available for used oil
recycling or disposal. Place contaminated materials in containers and dispose of in a manner consistent with
applicable regulations. Contact your sales representative or local environmental or health authorities for approved
disposal or recycling methods.

SECTION 14 TRANSPORT INFORMATION

The description shown may not apply to all shipping situations. Consult 49CFR, or appropriate Dangerous Goods
Regulations, for additional description requirements (e.g., technical name) and mode-specific or quantity-specific
shipping requirements.

DOT Shipping Description: NOT REGULATED AS HAZARDOUS MATERIAL UNDER 49 CFR

IMO/IMDG Shipping Description: NOT REGULATED AS DANGEROUS GOODS FOR TRANSPORT


UNDER THE IMDG CODE

ICAO/IATA Shipping Description: NOT REGULATED AS DANGEROUS GOODS FOR TRANSPORT


UNDER ICAO

SECTION 15 REGULATORY INFORMATION

REGULATORY LISTS SEARCHED:


01-1=IARC Group 1
01-2A=IARC Group 2A

_____________________________________________________________________
Revision Number: 0 5 of 6 Rando HDZ 46
Revision Date: November 15, 2019 SDS : 51575
01-2B=IARC Group 2B

No components of this material were found on the regulatory lists above.

CHEMICAL INVENTORIES:
All components comply with the following chemical inventory requirements: AICS (Australia), DSL (Canada),
ENCS (Japan), IECSC (China), KECI (Korea), PICCS (Philippines), TCSI (Taiwan), TSCA (United States).

SECTION 16 OTHER INFORMATION

REVISION STATEMENT: This is a new Safety Data Sheet. No revision information


Revision Date: November 15, 2019

The information is considered correct, but not exhaustive and is to be used only as guidance, which is based on the
current knowledge on the chemical substance or mixture and is applicable to the appropriate safety precautions for
the product.

ABBREVIATIONS THAT MAY HAVE BEEN USED IN THIS DOCUMENT:


TLV - Threshold Limit Value TWA - Time Weighted Average
STEL - Short-term Exposure Limit PEL - Permissible Exposure Limit
CAS - Chemical Abstract Service Number
ACGIH - American Conference of Governmental IMO/IMDG - International Maritime Dangerous
Industrial Hygienists Goods Code
API - American Petroleum Institute MSDS - Material Safety Data Sheet
CVX - Chevron NFPA - National Fire Protection Association (USA)
DOT - Department of Transportation (USA) NTP - National Toxicology Program (USA)
IARC - International Agency for Research on OSHA - Occupational Safety and Health
Cancer Administration

Prepared according to the Mexican Official Standard (NOM-018-STPS-2015) by Chevron Energy Technology
Company, 6001 Bollinger Canyon Road, San Ramon, CA 94583.

The above information is based on the data of which we are aware and is believed to be correct as of the date hereof.
Since this information may be applied under conditions beyond our control and with which we may be unfamiliar and
since data made available subsequent to the date hereof may suggest modifications of the information, we do not assume
any responsibility for the results of its use. This information is furnished upon condition that the person receiving it shall
make his own determination of the suitability of the material for his particular purpose.

_____________________________________________________________________
Revision Number: 0 6 of 6 Rando HDZ 46
Revision Date: November 15, 2019 SDS : 51575

You might also like