AAMA 501.2-03
Quality Assurance and
Diagnostic Water Leakage
Field Check of Installed
Storefronts, Curtain Walls,
and Sloped Glazing Systems
M A N U F A C T U R E R S A S S O C I A T I O N
TABLE OF CONTENTS
1.0 Scope and Purpose.............................................................1
LIST OF FIGURES
Figure 1: Storefront..................................................................3
© 2003
American Architectural Manufacturers Association
1827 Walden Office Square, Suite 550, Schaumburg, IL 60173
PHONE 847/303-5664 FAX 847/303-5774
EMAIL webmaster@aamanet.org WEBSITE www.aamanet.org
All AAMA documents may be ordered at our web site in the “Publications Store”.
The primary units of measure in this document are metric. NOTE: This test method may be conducted at pressures
The values stated in SI units are to be regarded as the lower than 205 kPa (30 psi) providing that the reason (i.e.
standard. The values given in parentheses are for not practical at a multistory building location) for not
reference only. achieving this pressure is 1) acceptable to the specifier, 2)
the pressure is not lower than 170 kPa (25 psi) and 3) the
reason and the actual pressure are so noted in the test
2.0 PREPARATION OF TEST AREA report as an exception to the method.
All framing and/or units shall be installed on the lower
two typical floors of the building for curtain wall testing 4.0 PROCEDURE
and on the lowest typical floor for storefront or sloped
glazing system testing. The area shall be fully glazed to 4.1 The designated test area shall be divided into and
provide a completed installation. All of this work shall be evaluated in 1.5 m (5 ft) sections of the framing and joint.
done in strict accord with approved shop drawings and The nozzle shall be held at a distance of 305 mm (1 ft)
job specifications. The architect and/or owner's +25 mm (1 in) from the location under test. Each 1.5 m
representative shall designate an area of the completed (5 ft) section of test area shall be evaluated for a period of
portion to be tested. The test area shall be a 5 minutes by slowly moving the nozzle back and forth
representative sample of typical construction and shall over the test section (see Figure 4) while maintaining the
have no outstanding punch list items or other visible nozzle perpendicular to the plane of the wall.
defects. If no test area and/or location has been identified,
the persons doing the test shall select an area. This area NOTE: It is recommended that a gauge be attached to
shall be selected to provide representative performance the end of the nozzle to ensure that the specified distance
data, usually a minimum of 9.3 m2 (100 ft2). The area to from the joint under test is maintained.
be tested shall include, perimeter caulking, typical splices,
frame intersections, and, if applicable, at least 2 entire 4.2 Working from the exterior, the wall test section shall
vision lites and 2 entire spandrel lites containing an be selectively wetted progressing from the lowest
intermediate vertical member and an intermediate horizontal framing member, then the adjacent framing
horizontal member. All operable components within the intersections, then the adjacent vertical framing members,
test area shall be isolated and exempt from the test etc. During the test, an observer on the indoor side of the
procedure. See Figures 1, 2 and 3 for typical test wall, using a flashlight if necessary, shall check for any
assemblies. water leakage and shall note where it occurs.
NOTE: Testing shall be performed as soon as possible NOTE: For this water leakage field check, water leakage
after the fenestration product is installed and prior to the is defined as any uncontrolled water that appears on any
installation of drywall or other interior finish wall normally exposed interior surfaces, that is not contained
materials. If interior wall materials have been installed or drained back to the exterior, or that can cause damage
V V
S S