Eurobrass 143: Pressure Reducing Valve
Eurobrass 143: Pressure Reducing Valve
Eurobrass 143: Pressure Reducing Valve
EUROBRASS 143
EUROBRASS 143
FIELDS:
The pressure reducing valves series EUROBRASS 143 are suitable for reduction and control of pressure in plants with the
following characteristics:
MATERIALS:
Metal of the body: Brass alloy CW617N UNI EN 12165 - CB753S EN 1984
Metal of the inner parts: Brass alloy CW614N UNI EN 12164
Seat: Stainless steel AISI 303
Bar: Brass alloy CW614N UNI EN 12164
Stainless steel AISI 3032
O-rings: NBR 70sh
FP75N 75sh¹
Flat gaskets: Fasit Italy
Plastic parts: Ultramid® A3K (BASF)
1
Only sizes 3" and 4".
2
Sizes from 1"¼ to 4".
1
Pressure always under control.
ITEM DN H L
143.38 3/8" 120 75
143.12 ½" 120 75
143.34 ¾" 150 85
143.33 1" 160 89
143.114 1" ¼ 220 125
143.112 1" ½ 220 130
143.58 2" 250 138
143.160 2" ½ 260 145
143.80 3" 285 177
143.100 4" 310 190
2
Pressure always under control.
In order to choose the best pressure reducers for any plant, we suggest to follow the indications mentioned in the
underexposed table with the best running pressure of the valves Eurobrass 143; the values are exposed both in
litres/minute and cbm/hour, and indicate the field of use where you can obtain the best functioning, silence and smaller
loss of charge of the valves.
The pressure reducers EUROBRASS 143 don’t get the effects – for their functioning – of the gravity force; therefore they
can be installed in the plant in any position:
Pressure reducing valves can be damaged by dirty water; therefore we advise to install a self-cleaning filter upstream
before the pressure reducer, in order to protect the valve and any other mechanism (thermostatic mixers, taps, etc.).
When there is a device which produce or store hot water or pipes are exposed to sudden changes in temperature, an
increase of outlet pressure may occur; this event is due to the raise in pressure that follows the temperature rising: an
expansion vessel between downstream the pressure reducing valve will avoid this problem.
We recommend moreover to install a Stopshock valve to prevent water hammer which would damage the inner parts of
the pressure reducer and other devices in the waterworks.
3
Test by ISTITUTO GIORDANO SPA - Bellaria - Italy
3
Pressure always under control.
_____________________________________________________________________________
RUBINETTERIA MALGORANI PIETRO SRL - Via per Invorio 24 - 28010 COLAZZA - NO -ITALY
Tel. +39 0322 218129 fax +39 0322 218301 info@malgorani.it
4