B03 Tai LH LHW 052021
B03 Tai LH LHW 052021
B03 Tai LH LHW 052021
Tsurumi LH/LH-W series pumps are submersible heavy-duty pumps specialized for high head. These pumps
are available in a wide lineup, offering 4 to 150HP motor output and 59 to 755ft. maximum head. The
LH/LH-W series has played an active role in various fields, from small/medium-scale civil engineering and
construction work that requires high reliability, to large-scale projects for constructing tunnels, bridges and
dams. And, because of the slim body, these pumps have particularly helped to drain mine pits where required
to work in limited space.
So that they can stand up to harsh environment, these pumps have the impeller and mouth ring made of
high-chromium cast iron that provides high wear resistance. The pump is equipped with seal pressure relief
ports* that release pump pressure applied to the mechanical seal. Furthermore, to endure even extended
operation at low water level, these pumps feature flow-thru design that forcibly cools down the motor. With
these features, Tsurumi pumps provide excellent reliability and durability that enables continuous duty for
long periods of time.
* excluding 4HP
Available as optional specifications are a proprietary “seawater-resistant pump” developed over many years
by Tsurumi to enable seawater intake/drainage for long periods of time, and an “all stainless steel pump”
using 316 stainless steel for mining markets.
LH: Lineup of pumps with high head in consideration of discharge volume.
LH-W: Comprised of dual impellers for extra high head.
Selection Table
4HP
20HP
25HP
30HP
LH
(Single Impeller) 40HP
50HP
60HP
75HP
100HP
150HP
2" 3" 4" 6" 8"
Discharge Bore
50mm 80mm 100mm 150mm 200mm
4HP
7.5HP
LH-W 15HP
(Dual Impellers) 30HP
40HP
150HP
Tandem operation model: Same model pumps are connected in series, to deliver higher head.
LH 3 22 W
Options
Seawater-resistant version; Galvanic anode & Special impeller
High temperature liquid version; Max. 194ºF
High voltage version; Max. 1000V
All stainless steel version; 316 S.S.
2
Top Discharge, Flow-thru Design
This design provides maximum motor cooling efficiency allowing continuous operation at
low water levels and extended dry-run capability, and also allows the shape of the pump
to be cylindrical and slim for installation in a well casing for deep well dewatering.
Model
LH4110W
3
4
6
7
4
LH -Single Impeller-
The LH-series is a submersible three-phase cast iron high head drainage pump. Being the pump cylindrical
and slim, it can be installed in a well casing for deep well dewatering. The center flange construction assures
a stable installation even if it is fixed by the discharge pipe. The top discharge, flow-thru design provides
maximum motor cooling efficiency allowing continuous operation at low water levels and extended dry-run
capability. The pump incorporates seal pressure relief ports that prevent the pumping pressure from applying
to the shaft seal.*
* excluding LH33.0
5
Performance Curves
< High Head >
800
60 Hz
700
LH61
600 10
500
LH6 75
400
300
LH6
LH430 45
200 LH
LH
422
63
7
100 LH LH
LH 61 62
33
.0 5 LH6 2
19
0
0 200 400 600 800 1000 1200 1400 1600 1800
60 Hz
700
600
500
400
LH81
300 10
LH8 7
200 5
LH8
5
LH8 5
45
100 LH8
37
0
0 200 400 600 800 1000 1200 1400 1600 1800
6
LH-W -Dual Impellers-
The LH-W-series is a submersible three-phase cast iron extra high head drainage pump having dual
impellers. Being the pump cylindrical and slim, it can be installed in a well casing for deep well dewatering.
The center flange construction assures a stable installation even if it is fixed by the discharge pipe.*1 The
top discharge, flow-thru design provides maximum motor cooling efficiency allowing continuous operation
at low water levels and extended dry-run capability. The pump incorporates seal pressure relief ports that
prevent the pumping pressure from applying to the shaft seal.*2
*1 excluding LH4110W
*2 excluding LH23.0W
7
Performance Curves
< 4-40HP >
450
400
60 Hz
350
300
250
200
150
100
50
0
0 50 100 150 200 250 300 350
60 Hz
800
LH41
10W
700
600
500
400
300
200
100
0
0 50 100 150 200 250 300 350 400 450 500 550 600
8
9
“Tandem operation” is an operation method that connects
two pumps of the same model in series. This provides double
pump head at the same flow rate in comparison with that of a
single pump. The principle of tandem operation is the same as that
with multistage pumps.
Lifting Chain
or Wire Rope Precautions for Selection and Use
For model selection, piping and installation procedure, be sure to
consult Tsurumi distributors in advance.
1. If the required total head exceeds the maximum head of the pump
without the intermediate connection pipe shown in the selection table,
Discharge Head of insert a intermediate connection pipe of a length corresponding to the
Upper Stage Pump excess amount or more, to reduce the pressure applied to the pump
in the upper stage.
3. The pump in the lower stage should be installed at the bottom of the
Seal Pressure vertical hole, unless special measures are taken. Do not suspend the
Relief Port
pump in midair. Do not allow the weight of the upper pump and piping
to be applied to the lower pump.
Lower Pump Casing
for Tandem Connection 4. Since a certain amount of water spouts from the seal pressure relief
port,* both the upper- and lower-stage pumps should be installed
in the vertical hole. Do not use the pumps as booster pumps in the
Companion Flange middle of a horizontal line lying on the ground.
(Option) * excluding LH33.0 and LH23.0W
Intermediate 5. Do not connect pumps of different models in series. Do not use either
Connection Pipe
of two connected pumps singly. Failure to observe these instructions
may change the operating point improper, resulting in trouble.
Continuous
Running Water Level
10
Tandem Operation -LH / LH-W-
“Tandem operation” is an operation method that connects two pumps of the same model in series. This provides
double pump head at the same flow rate in comparison with that of a single pump. The principle of tandem
operation is the same as that with multistage pumps. The LH and LH-W series pumps adopt the center flange
construction to align the discharge pipe with the cylindrical pump center axis.* Connecting the pumps in series
with the tandem connector can provide higher pump head without affecting the advantage of the slim design. At
construction sites, there are many cases where a higher pump head is required as construction work progresses.
In such cases, the addition of a tandem pump may meet the required pump head, instead of using a new pump.
* Available as an option for separately purchased LH33.0 and LH23.0W.
LH23.0W
for Tandem Operation
Motor Discharge Starting Max. Head Max. Head Dimensions Dry Allowable Cable
Model Output Bore Method in Tandem w/o Intermediate Dia. x Height Weight *2 Load on Length
Connetion Pipe Eyebolts
HP inch ft ft inch lbs lbs ft
LH33.0 4 3 D.O.L. 118 / 144 108 7 5/16 x 28 3/4 119 331 65
LH23.0W 4 2 D.O.L. 256 / 282 164 7 5/16 x 29 7/8 130 331 65
LH25.5W 7.5 2 D.O.L.*1 427 320 9 5/8 x 31 13/16 212 485 65
LH311W 15 3 D.O.L.*1 531 399 10 5/8 x 41 1/16 276 992 65
LH322W 30 3 D.O.L.* 1
669 / 709 531 13 x 49 7/16 805 2094 65
LH430W 40 4 Star-Delta 807 / 833 625 14 3/8 x 55 1/8 858 2094 65
*1 Star-Delta available upon request
*2 Weights excluding cable
11
Performance Curves REMARKS:
The intermediate connection pipe is not required in the range indicated as a bold line on curves. If the required total head exceeds the maximum head of the pump
without an intermediate connection pipe (indicated as dashed line), an intermediate connection pipe of a length corresponding to the excess amount or more is equired.
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 0 20 40 60 80 100 120 140 160 180 200 220
100
100
50
0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 0 40 80 120 160 200 240 280 320 360
12
Specifications
LH
LH33.0 LH422 LH430 LH615 LH619 LH622 LH637 LH645 LH675 LH6110
Threaded
Discharge Connection Hose JIS 10kg/cm2 Flange JIS 20kg/cm2 Flange
Connector
Semi-open Closed
Impeller
High-chromium Cast Iron
Phase Three-phase
Pole 2
Insulation F B F B F
Motor Protector
MOTOR
Leakage Sensor
Electrode
(built-in)
ft 65 32 65
Cable
Chloroprene Rubber
Dry Weight* lbs 93 770 780 470 770 790 1090 1120 1910 2670
8 2 3 4
Threaded
JIS 10kg/cm2 Flange Hose JIS 10kg/cm2 Flange JIS 20kg/cm2 Flange
Connector
Silicon Carbide
Three-phase
F B F
Electrode Electrode
32 65
Chloroprene Rubber
1090 1120 1810 1910 2670 101 176 287 670 714 2800
14
1625 Fullerton Court, Glendale Heights, IL 60139
Tel: 1-888-878-7864 • Fax: 1-630-793-0146
www.tsurumipump.com • info@tsurumiamerica.com B03_TAI_LH_LHW_052021