Steps of Updating PLC Program by Pendrive

Download as pdf or txt
Download as pdf or txt
You are on page 1of 5

Steps of updating PLC program by pendrive

1. Attention:
1) EX2N/EX3G-KH/KHA/HA series HMI PLC all in one supports U disk update
PLC function, and HMI firmware version is V5.78 and above)
2) If the product is an EX3G-KH/KHA/HA series HMI PLC all in one, you must
first change the PLC type to FX2N(C) in the PLC software, as shown below.

3) The PLC program must not contain instructions that are not supported by
the FX2N series PLC, otherwise it will not be saved.
4) The function of "Write to FXGP (WIN) format file" is supported only in
GX8.52 and GX8.86 versions.

2. Operation steps

1) Open the PLC programming software (GX developer 8.52E or GX developer 8.86Q)
and click "Project - Write other files in the format --- Write FXGP (WIN) format file", as
shown in the figure:

1 www.coolmayplc.com
Before execution, you need to enter the file name, and check the "Program Files"
option in "Parameter + Program" to set the file storage path (but only support the root
directory of the disk), and then click Execute, Generate "**.PMW" in the root directory of
the set disk. This example is generated as "24.PMW", as shown in the figure:

2 www.coolmayplc.com
2) Insert the USB flash drive (the file system is FAT32) onto the computer, copy and
paste the “24.PMW” file into the root directory of the USB flash drive (ie, do not put it in
any folder)---plug the USB flash drive into the product USB. Port---- will jump to the USB
setting screen, click "Update *.HW6/.PMW file", enter the current password of the touch
screen project (default is 12345678), as shown in the
figure:

3 www.coolmayplc.com
3) In the lower right corner of the USB setting screen, find the .PMW file to be updated.
Double-click - click "Yes" to execute the download task, as shown in the figure:

4 www.coolmayplc.com
4) After the progress bar is updated, the touch screen will automatically restart. After the
restarting, the PLC program is successfully downloaded to the HMI PLC all in one.

Attachment: How to export .PMW file from 3G series plc program

Use the serial cable 232 or 485 to connect the PLC, → open the reading tool, select the
serial port corresponding to the computer device manager, and then read it in. → the step
starts counting. When the counting does not go, close the software. → This will be in the
directory. Generate a duqu.pmw file, → copy this file to the U disk and use the touch
screen to write to the PLC program (moban.PMW to be placed in the same directory as
the PMW read tool EXE)