Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Turolla Catalog Gear Pump Cascade3

Download as pdf or txt
Download as pdf or txt
You are on page 1of 30

Orange - CMYK 99%Y 76%M

Grey - CMYK 44% Black

CAST IRON GEAR PUMPS AND MOTORS


Cascade Group 3 l Technical Information

66M 77C 50C


88Y 55K
33M 100Y

66M
88Y
2 CASCADE GROUP 3 I TECHNICAL INFORMATION

History of revisions

Date Page Changed Rev.

March 2015 - First edition -

September 2016 - Second edition -

© 2016 Turolla ™. All rights reserved.

Turolla accepts no responsibility for possible errors in catalogs, brochures and other printed material. Turolla reserves the right to alter its products without prior notice. This also applies to products already
ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners.
Danfoss, Turolla, Turolla OpenCircuitGear, OpenCircuitGear, Fast Lane and PLUS+1 are trademarks of the Danfoss Group.

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 3

Contents

General Information
4 Description
5 Formulas used for calculation
6 Application parameters
9 Technical data
10 Flow rate and power curves
13 Model code
18 Flange types
19 Shaft types
21 Combinations of flanges and shafts
22 Port types
24 Outrigger bearings
25 Aux pads
26 Configuration examples

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
4 CASCADE GROUP 3 I TECHNICAL INFORMATION

Description

Overview
Cascade fixed displacement gear pump and motor has been specifically designed for
demanding mobile equipment applications where maximum performance is required at
peak power levels and operating temperatures. The design integrates cast iron construction
with pressure balanced thrust plates to deliver consistent efficiency across the entire
operating range of pressure, speed, and temperature.

The three structural members of the pump and motor are: flange, body and cover, are made
of high-strength cast iron. Cast iron provides contamination resistance, thermal stability and
the strength needed for consistently high levels of performance and durability needed in
demanding off highway applications.

Sleeve bushings are pressed in the flange and cover and have been optimized to provide
long life in low viscosity, high pressure conditions. Axial pressure balance is ensured by
aluminium alloy thrust plates with integrated pressure seals.

In order to accomodate the strictest demands for external radial and axial force, most of the
flange types are available also with the optional integrated outrigger bearings.

Cascade Group 3 pumps can be coupled together to produce tandem, triple and even
quadruple units. The interconnecting chambers can accommodate fluid flow between
sections and allow the number of inlet connections to be minimized.

Cascade Group 3 pumps and motors cover the wide range of displacements from 17 to 71
cm3.

DESIGN

1. Body
2. Flange
3. Cover
4. Drive gear
5. Driven gear
6. Pressure seal
7. Anti-extrusion ring
8. O-ring
9. Pressure plates
10. Shaft seal
11. Snap ring
12. Assembly screws
13. Spring washer
14. Centering tube

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 5

Formulas used for calculation

Determination of nominal pump sizes


Use these formula to determine the nominal pump size for a specific application:

Based on SI units Based on US units

Vg • n • η
Vg • n • ηv
Output flow: Q = l/min Q = v [US gal/min]
1000 231

Vg • ∆p Vg • ∆p
Input torque: M = N•m M = [lbf•in]
20 • π • ηm
2 • π • ηm

M • n Q • ∆p M • n Q • ∆p
Input power: P = = kW P = = [hp]
9550 600 • ηt 63.025 1714 • ηt

Variables: SI units [US units]

Vg = Displacement per rev. cm3/rev [in3/rev]


pHD = Outlet pressure bar [psi]
pND = Inlet pressure bar [psi]
∆p = pOUT – pIN bar [psi]
n = Speed min-1 (rpm)
ηv = Volumetric efficiency
ηm = Mechanical (torque) efficiency
ηt = Overall efficiency (ηv • ηm)

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
6 CASCADE GROUP 3 I TECHNICAL INFORMATION

Application parameters

Hydraulic fluids
Ratings and data for Cascade gear pumps are based on operating with premium hydraulic fluids
containing oxidation, rust, and foam inhibitors. These fluids must possess good thermal and
hydrolytic stability to prevent wear, erosion, and corrosion of internal components. They include:
• Hydraulic fluids following DIN 51524, part 2 (HLP) and part 3 (HVLP) specifications
• API CD engine oils conforming to SAE J183
• M2C33F or G automatic transmission fluids
• Certain agricultural tractor fluids

Use only clean fluid in the pump and hydraulic circuit.

Caution

Never mix hydraulic fluids.

Please see Turolla publication Hydraulic Fluids and Lubricants Technical Information, L1021414
for more information.

Temperature and Viscosity


Temperature and viscosity requirements must be concurrently satisfied. Use petroleum /
mineral-based fluids.

High temperature limits apply at the inlet port to the pump. The pump should run at or below the
maximum continuous temperature. The peak temperature is based on material properties. Don’t
exceed it.

Cold oil, generally, doesn’t affect the durability of pump components. It may affect the ability of oil
to flow and transmit power. For this reason, keep the temperature at 16 °C
[60 °F] above the pour point of the hydraulic fluid.

Minimum (cold start) temperature relates to the physical properties of component materials.
Minimum viscosity occurs only during brief occasions of maximum ambient temperature and
severe duty cycle operation. You will encounter maximum viscosity only at cold start. During this
condition, limit speeds until the system warms up. Size heat exchangers to keep the fluid within
these limits. Test regularly to verify that these temperatures and viscosity limits aren’t exceeded.
For maximum unit efficiency and bearing life, keep the fluid viscosity in the recommended
viscosity range.

Fluid viscosity Temperature


Maximum (cold start) 1200 [5500] Minimum (cold start) -20 [-4]
mm2/s °C
Recommended range 20-80 [97-365] Maximum continuous 90 [194]
[SUS] [°F]
Minimum 10 [60] Peak (intermittent) 110 [230]

Filtration

Filters
Use a filter that conforms to Class: 21/18/15 (for pressure p2 < 200 bar) 10 (for pressure p2 < 200 bar)
20/17/14 (for pressure p2 > 200 bar) 8 (for pressure p2 > 200 bar)
according to ISO 4406 according to NAS 1683

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 7

Selecting a filter
• When selecting a filter, please consider:
• contaminant ingression rate (determined by factors such as the number of actuators used in
the system)
• generation of contaminants in the system
• required fluid cleanliness
• desired maintenance interval
• filtration requirements of other system components

βx ratio is a measure of filter efficiency defined by ISO 4572. It is the ratio of the number of particles greater than a given
diameter ( “X“ in microns) upstream of the filter to the number of these particles downstream of the filter.

Fluid cleanliness level and βx ratio


Fluid cleanliness level (per ISO 4406) 21/18/15 or better (for pressure p2 < 200 bar)
20/17/14 or better (for pressure p2 > 200 bar)
βx ratio (suction filtration) β35-45 = 75 and β10 = 2
βx ratio (pressure or return filtration) β10 = 75
Recommended inlet screen size 100-125 µm [0.004-0.005 in]

The filtration requirements for each system are unique. Evaluate filtration system capacity by
monitoring and testing prototypes.

Pressure load

p2n rated pressure the average, regularly occuring operating pressure that should
yield satisfactory product life. The maximum machine load
demand determines rated pressure. For all systems, the load
should be below this pressure.
p2max intermittent pressure maximum pressure permissible for a short time, max. 20s. at a
time
p3 peak pressure the highest intermittent pressure allowed. The relief valve
overshoot (reaction time) or directional valve midpositon
usually determines peak pressure. It is assumed to occur for less
that 100ms at a time.

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
8 CASCADE GROUP 3 I TECHNICAL INFORMATION

Pump drive
Shaft options for Cascade gear pumps include tapered, splined, or parallel shafts. They are
suitable for a wide range of direct and indirect drive applications for radial and thrust loads.

Plug-in drives, acceptable only with


a splined shaft, can impose severe radial loads when
the mating spline is rigidly supported. Increasing spline
clearance does not alleviate this condition.

Use plug-in drives if the concentricity between the mating


spline and pilot diameter is within 0.1 mm [0.004 in].
Lubricate the drive by flooding it with oil. A 3-piece coupling
minimizes radial or thrust shaft loads.

Caution

In order to avoid spline shaft damages it is recommended to use carburised and hardened steel
couplings with 80-82 HRA surface hardness.

Allowable radial shaft loads are a function of the load position, load orientation, and operating
pressure of the hydraulic pump. All external shaft loads have an effect on bearing life, and may
affect pump performance.
In applications where external shaft loads can’t be avoided, minimize the impact on the pump by
optimizing the orientation and magnitude of the load and selecting a pump with an approptiate
outrigger bearing. Don’t use splined shafts for belt or gear drive applications. A spring-loaded belt
tension-device is recommended for belt drive applications to avoid excessive tension.

Direction of Rotation

Determine direction of rotation by looking at the drive shaft. The pump can only be used in the
specified direction of rotation.

Bidirectional pumps and motors

The pumps and motors with the possibility of bidirectional rotation have a different internal
arrangement requiring drainage. Two types of drain are used - internal and external. The internal
drainage is always interconnected with the low pressure side outlet by means of valves. The
external drainage is a port located in the cover opposite the driven gear.

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 9

Technical data

Cascade3 Cascade3 Cascade3 Cascade3 Cascade3 Cascade3 Cascade3 Cascade3 Cascade3


Nominal Size Parameters Sym. Unit
17 22 27 34 43 51 56 61 71

Actual displacement Vg
cm3/rev 17.39 22.46 27.53 34.05 43.47 51.44 55.79 61.59 71.01
[in3/rev] [1.061] [1.370] [1.679] [2.078] [2.653] [3.139] [3.405] [3.758] [4.333]
min -1
nominal nn
[rpm] 1500
min -1
Rotation speed minimum nmin
[rpm] 400 400 400 400 400 350 350 350 350
min -1
maximum nmax
[rpm] 3200 3200 3200 3000 2800 2600 2400 2200 1800
bar
minimum p1min
[psi] -0.3 [-4.3]
Pressure at inlet
bar
maximum p1max
[psi] 3 [43.5]

max. p2n
bar 300 300 300 300 280 260 250 230 210
continuous [psi] [4350] [4350] [4350] [4350] [4060] [3770] [3620] [3330] [3040]
Pressure at outlet * maximum p2max
bar 320 320 320 320 300 280 270 250 230
[psi] [4640] [4640] [4640] [4640] [4350] [4060] [3900] [3620] [3330]
peak p3
bar 330 330 330 330 310 290 280 260 240
[psi] [4780] [4780] [4780] [4780] [4500] [4200] [4060] [3770] [3480]
l/min
Nominal flow rate (min.) at nn and
Qn [US gal/ 23.5 31 38 48 61.3 72.5 78.7 86.8 100.1
p2n
min] [6.2] [8.2] [10] [12.7] [16.2] [19.1] [20.8] [22.9] [26.4]
l/min
Maximum flow rate at nmax and
Qmax [US gal/ 54.5 70.4 86.3 100.1 119.3 131.1 131.2 132.8 125.3
p2max
min] [14.4] [18.6] [22.8] [26.4] [31.5] [34.6] [34.6] [35.1] [33.1]
Nominal input power (max.) at nn
Pn
kW 16.1 20.3 24.9 30.2 36 39.5 41.2 41.9 44.1
and p2n [HP] [21.6] [27.2] [33.4] [40.5] [48.2] [53] [55.2] [56.2] [59.1]
Maximum input power at nmax and
Pmax
kW 33.6 43.5 53.3 61.8 69 70.8 68.3 64 55.6
p2max [HP] [45] [58.3] [71.5] [82.8] [92.5] [95] [91.6] [85.8] [74.5]
Weight m
kg  15.3  15.6  15.7  16.2  16.7  17.1 17.3 17.6 18.1
[lb] [33.7] [34.4] [34.6] [35.7] [36.8] [37.7] [38.1] [38.8] [39.9]
* reversible pumps have outlet pressure ratings decreased by 10%

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
10 CASCADE GROUP 3 I TECHNICAL INFORMATION

Flow rate and power curves

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 11

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
12 CASCADE GROUP 3 I TECHNICAL INFORMATION

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 13

Model code

A B C D E F G H I J K L M N O P
- - - - - - - - - - - - - - -

F2 G2 H2 I2 F3 G3 H3 I3 F4 G4 H4 I4
- - - - - - - - -
Second section Third section Fourth section
Use this part to define additional sections of multiple pumps

A B

Code Family Code Type (Number of sections)


1 Single, (One)
CAS Cascade 2 Tandem, (Two)
3 Triple, (Three)
C 4 Quadruple, (Four)
M Motor
Code Rotation Direction

L Left (Counterclockwise) D
R Right (Clockwise)
Code Mouting Flange
I Bidirectional (Internally Drained)
AA SAE-A 2 bolt
E Bidirectional (Externally Drained) BB SAE-B 2 bolt
B4 SAE-B 4 bolt
C2 SAE-C 2 bolt
C6 SAE-C 2+4 bolt (universal)
II ISO

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
14 CASCADE GROUP 3 I TECHNICAL INFORMATION

A B C D E F G H I J K L M N O P
- - - - - - - - - - - - - - -

F2 G2 H2 I2 F3 G3 H3 I3 F4 G4 H4 I4
- - - - - - - - -
Second section Third section Fourth section
Use this part to define additional sections of multiple pumps

E F

Code Shaft Type Code Frame Size

BA 1:8 Tapered Shaft 3 Group 3


AA 1:5 Tapered Shaft
SE Spline SAE A 9T G
SC Spline SAE A 11T
Displacement
Code
SH Spline SAE B 13T (cc) in^3
S0 Spline SAE C 14T * 017 17,39 1,06
SV Spline SAE BB 15T 022 22,50 1,37
S3 Spline DIN 5462 027 27,53 1,68
S7 Spline DIN 5480 * 034 34,05 2,08
PB Cylindric SAE B 7/8" 043 43,47 2,65
PZ Cylindric SAE BB 1" 051 51,44 3,14
P3 Cylindric SAE C 1-1/4" * 056 55,79 3,40
* available only incombination with heavy duty outrigger 061 61,59 3,76
bearing (type H in the model code)
071 71,01 4,33

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 15

A B C D E F G H I J K L M N O P
- - - - - - - - - - - - - - -

F2 G2 H2 I2 F3 G3 H3 I3 F4 G4 H4 I4
- - - - - - - - -
Second section Third section Fourth section
Use this part to define additional sections of multiple pumps

H I
A2 3/4" SAE Flange
Inlet (H) and Outlet (I) Ports A3 1" SAE Flange
Code Port Type Description A4 1-1/4" SAE Flange
DA 27 x 1.5 Metric ORB A5 1-1/2" SAE Flange
DB 27 x 2 Metric ORB A6 2" SAE Flange
DD 33 x 1.5 Metric ORB M4 3/4" SAE Flange Metric
DE 33 x 2 Metric ORB M5 1" SAE Flange Metric
F5 G 3/4 BSP/GAS M6 1-1/4" SAE Flange Metric
F6 G1 BSP/GAS M7 1-1/2" SAE Flange Metric
F7 G 1-1/4 BSP/GAS M8 2" SAE Flange Metric
E6 1-1/16 - 12 UN SAE ORB C7 18x40xM8 EU Flange (+)
E8 1-5/16 - 12 UN SAE ORB CO 18x55xM8 EU Flange (+)
E9 1-5/8 - 12 UN SAE ORB CA 26x51xM10 EU Flange (+)
BM 18 x 40 x 4xM8 DIN Flange (X) CP 25x55xM8 EU Flange (+)
BA 18 x 55 x 4xM8 DIN Flange (x) NN - No port
B5 15 x 35 x 4xM6 DIN Flange (x) T1 1" Tube Inlet
B7 20 x 40 x 4xM6 DIN Flange (x) T2 1-1/4" Tube Inlet
BN 25 x 55 x 4xM8 DIN Flange (x) T3 1-1/2" Tube Inlet
BO 26 x 51 x 4xM10 DIN Flange (X) T4 2" Tube Inlet
Note: When selecting multiple pump with single inlet, please specify required inlet size in the
required section and specify NN (no port) for inlets in other sections

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
16 CASCADE GROUP 3 I TECHNICAL INFORMATION

A B C D E F G H I J K L M N O P
- - - - - - - - - - - - - - -

F2 G2 H2 I2 F3 G3 H3 I3 F4 G4 H4 I4
- - - - - - - - -
Second section Third section Fourth section
Use this part to define additional sections of multiple pumps

J K

Port Configuration Case Drain Options

Code Type Code Dimension Port Type

A Axial Ports N N/A No Drain


R Radial Ports 1 M16x1.5 Metric ORB
I Radial Inlet+Axial Outlet 2 M18x1.5 Metric ORB
O Axial Inlet+Radial Outlet 4 G 1/4" BSP/GAS
Quad ports (Radial AND Axial 5 G 3/8" BSP/GAS
Q
ports) 6 G 1/2" BSP/GAS
8 9/16"-18 UNF SAE ORB
L
M
Internal Seal Options

Code Description
Outrigger bearing option
N NBR Code Description
B Viton N Without outrigger Bearing
G HNBR M Medium Duty Outrigger Bearing
* Applies to shaft seal and case O-ring material. H Heavy Duty Outrigger Bearing
Pressure seals are always NBR
I ISO Outrigger Bearing*

N * Available only with ISO Flange (type II in the model


code)

Aux pad option

Code Description

N Without aux pad


1 SAE-A 9T Aux Flange
2 SAE-A 11T Aux Flange
Turolla • September 2016
CASCADE GROUP 3 I TECHNICAL INFORMATION 17

A B C D E F G H I J K L M N O P
- - - - - - - - - - - - - - -

F2 G2 H2 I2 F3 G3 H3 I3 F4 G4 H4 I4
- - - - - - - - -
Second section Third section Fourth section
Use this part to define additional sections of multiple pumps

Wet mount option

Code Description

N Standard shaft seal, flange pilot diameter not sealed


O Standard shaft seal, O-ring on flange pilot diameter
W Double sided shaft seal, O-ring on flange pilot diameter

Special Configuration

Code Description

NNN Standard black Paint


* Special features (e.g. customer p.n., customized name plate, others)*
* contact Turolla for code specification

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
18 CASCADE GROUP 3 I TECHNICAL INFORMATION

Flange types

AA BB

B4 C6

C2 II

* With ISO outrigger bearing ("I" in model code position M)


II

* Without outrigger bearing ("N" in model code position M)

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 19

Shaft types

BA AA SE

SC SH S0

SV S3

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
20 CASCADE GROUP 3 I TECHNICAL INFORMATION

S7 PB

PZ P3

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 21

Combinations of flanges and shafts

Flange Type SAE-A SAE-B SAE-B SAE-C SAE-C


2 bolt 4 bolt 2 bolt 4+2 bolt ISO square
Model
AA BB B4 C2 C6 II R6
Code
Shaft Type

1:8 Tapered Shaft BA a a a

1:5 Tapered Shaft AA a a a

Spline SAE A 9T SE S a a a a

Spline SAE A 11T SC S a a a a

Spline SAE B 13T SH S S S a a

Spline SAE C 14T * SO a a S S

Spline SAE BB 15T SV a S S a a

Spline DIN 5462 S3 S

Spline DIN 5480 * S7 S

Cylindric SAE B 7/8" PB a S S a a

Cylindric SAE BB 1" PZ a S S a a

Cylindric SAE C 1-1/4" * P3 a a S S

* Only available with ORB S-Standard a - Available

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
22 CASCADE GROUP 3 I TECHNICAL INFORMATION

Port types

Metric thread according to ISO 6149


Displacement Inlet Outlet
[cm3] Code A B C D Code A B C D
Cascade 3 17 - 51 DE M 33x2 18 40 DB M 27x2 16 33
1 1
Cascade 3 51 - 71 DF M 48x2 22 56 DE M 33x2 18 40

BSPP pipe thread according to ISO 228 - 1


Displacement Inlet Outlet
[cm3] Code A B C D Code A B C D
Cascade3 17 - 34 F6 G 1“ 18 45 F5 G 3/4 16 39
1 1
Cascade3 34 - 71 F7 G 1 1/4 24 58 F6 G 1“ 18 45

UNF thread according to SAE


Displacement Inlet Outlet
[cm3] Code A B C D Code A B C D
Cascade3 17 - 34 E8 1–5/16–12UN 49 E6 1–1/16–12UN 41
19 1 19 1
Cascade3 34 - 71 E9 1–5/8–12UN 58 E8 1–5/16–12UN 49

Flanged fittings according to DIN

Inlet Outlet
Displacement [cm3] Code Code
E F G H E F G H
BO 26 M10 51 BM 20 40
Cascade3 17 - 51 16 M8 16
BN 25 M8 55 BA 18 55
Cascade3 10 - 17 B7 20 M6 13 40 B5 15 M6 13 35

Note: Available only as side ports

Flanged fittings according to SAE, metric thread


Displacement Inlet Outlet
Code Code
[cm3] E F G H I E F G H I
Cascade 3 17 - 34 M5 25.4 52.4 26.2 M4 19.0 47.6 22.2
M10 22
Cascade3 34 - 51 M6 30.5 58.7 30.2 M5 25.4 M10 22 52.4 26.2
Cascade3 51 - 71 M7 39.3 M12 27 69.8 35.7 M6 30.5 58.7 30.2
Cascade3 (single
Inlet on multile M8 51.0 M12 27 77.8 42.9
pump)

Note: Available only as side ports

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 23

Flanged fittings according to SAE, UNC thread

Displacement Inlet Outlet


Code E F G H I Code E F G H I
[cm3]
Cascade 3 17 - 34 A3 25.4 3/8-16 UNC-2B 22 52.4 26.2 A2 19.0 47.6 22.2
3/8-16 UNC-2B 22
Cascade3 34 - 51 A4 30.5 7/16-14 UNC-2B 28.5 58.7 30.2 A3 25.4 52.4 26.2
Cascade3 51 - 71 A5 39.3 1/2-13 UNC-2B 27 69.8 35.7 A4 30.5 7/16-14 UNC-2B 29 58.7 30.2
Cascade3 (single
Inlet on multile A6 51.0 1/2-13 UNC-2B 27 77.8 42.9
pump)

Note: Available only as side ports

Flanged fittings – “cross“


Displacement Inlet Outlet
Code Code
[cm3] E F G H E F G H
CA 26 M10 18 51 C7 18 40
Cascade3 17 - 51 18 M8
CP 25 M8 16 55 CO 16 55

Note: Available only as side ports

Tube Inlets
Inlet
Displacement [cm3] Code
A D
Cascade 3 17 - 34 T1 25,4 27,6
Cascade3 34 - 51 T2 31,7 29,7
Cascade3 51 - 71 T3 38,1 31,5
Cascade 3 tandems/triples (single inlet) T4 50,8 29,7

Drain ports:
Case Drain Options

Code Dimension Port Type

N N/A No Drain

1 M16x1.5 Metric ORB

2 M18x1.5 Metric ORB

4 G 1/4" BSP/GAS

5 G 3/8" BSP/GAS

6 G 1/2" BSP/GAS

8 9/16"-18 UNF SAE ORB

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
24 CASCADE GROUP 3 I TECHNICAL INFORMATION

Q (Quad ports) options:


In case of quad ports, there are both rear and side ports present. Rear and side inlet of the same
type and size are specified by position E in the model code, rear and side outlet of the same type
and size are specified by position I in the model code. The products with quad port configuration
are delivered with rear ports fitted with sealed metal plugs.

Outrigger bearings

Type M (Medium duty bearing)


The need for an additonal outrigger
bearing depends on many factors including
but no limited to magnitude of external
force, direction of external force, point of
effect on the shaft, load cycle etc. When in
doubt if an outrigger bearing is necessary,
contact Turolla technical support with
application parameters.

Type H (Heavy duty bearing) Type I (ISO bearing)

Note: Available only with ISO Flange (II)

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 25

Aux pads
Type 1 (accomodates SAE-A flange, 9T shaft)

Type 2 (accomodates SAE-A flange, 11T shaft)

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
26 CASCADE GROUP 3 I TECHNICAL INFORMATION

Configuration examples

CAS-1-R-BB-SH-3-071-BN-BA-R-N-N-NNN-NNN R
71 250 1 800 63.7 128.5 168.3
CAS-1-L-BB-SH-3-071-BN-BA-R-N-N-NNN-NNN L
CAS-1-R-BB-SH-3-051-BN-BA-R-N-N-NNN-NNN R
51 350 2 600 59.0 119.1 158.9
CAS-1-L-BB-SH-3-051-BN-BA-R-N-N-NNN-NNN L
CAS-1-R-BB-SH-3-043-BN-BA-R-N-N-NNN-NNN R
43 400 2 800 48.8 98.6 138.4
CAS-1-L-BB-SH-3-043-BN-BA-R-N-N-NNN-NNN L
CAS-1-R-BB-SH-3-034-BN-BA-R-N-N-NNN-NNN R
34 400 3 000 45.6 92.3 132.1
CAS-1-L-BB-SH-3-034-BN-BA-R-N-N-NNN-NNN L
CAS-1-R-BB-SH-3-027-BN-BA-R-N-N-NNN-NNN R
27 400 3 200 44.0 89.2 129.0
CAS-1-L-BB-SH-3-027-BN-BA-R-N-N-NNN-NNN L
CAS-1-R-BB-SH-3-017-BN-BA-R-N-N-NNN-NNN R
17 400 3 200 42.5 86.0 125.8
CAS-1-L-BB-SH-3-017-BN-BA-R-N-N-NNN-NNN L
DISPLA- MIN. MAX. A B C
DIRECT.
Model Code CEMENT SPEED DIMENSION
OF ROT.
[cm3 /1] [min-1] [mm]

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 27

CAS-2-R-BB-SH-3-071-F7-F6-3-051-F6-F5-R-N-N-N-N-N-NNN R
71 51 350 1800 178 121 331,5 372,7
CAS-2-L-BB-SH-3-071-F7-F6-3-051-F6-F5-R-N-N-N-N-N-NNN L
CAS-2-R-BB-SH-3-061-F7-F6-3-043-F6-F5-R-N-N-N-N-N-NNN R
61 43 400 2200 171,5 115,5 319,5 360,7
CAS-2-L-BB-SH-3-061-F7-F6-3-043-F6-F5-R-N-N-N-N-N-NNN L
CAS-2-R-BB-SH-3-056-F7-F6-3-034-F6-F5-R-N-N-N-N-N-NNN R
56 34 400 2400 167,5 109 309 350,2
CAS-2-L-BB-SH-3-056-F7-F6-3-034-F6-F5-R-N-N-N-N-N-NNN L
CAS-2-R-BB-SH-3-051-F7-F6-3-027-F6-F5-R-N-N-N-N-N-NNN R
51 27 400 2600 164,5 104,5 301,5 342,7
CAS-2-L-BB-SH-3-051-F7-F6-3-027-F6-F5-R-N-N-N-N-N-NNN L
CAS-2-R-BB-SH-3-043-F7-F6-3-022-F6-F5-R-N-N-N-N-N-NNN R
43 22 400 2800 159 101 292,5 333,7
CAS-2-L-BB-SH-3-043-F7-F6-3-022-F6-F5-R-N-N-N-N-N-NNN L
CAS-2-R-BB-SH-3-034-F7-F6-3-017-F6-F5-R-N-N-N-N-N-NNN R
34 17 400 3000 152,5 97,5 282,5 323,7
CAS-2-L-BB-SH-3-034-F7-F6-3-017-F6-F5-R-N-N-N-N-N-NNN L
DISPLA- MIN. MAX. A1 A2 B C
DIRECT.
Model Code CEMENT SPEED DIMENSION
OF ROT.
[cm3 /1] [min-1] [mm]

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
28 CASCADE GROUP 3 I TECHNICAL INFORMATION

Notes

Turolla • September 2016


CASCADE GROUP 3 I TECHNICAL INFORMATION 29

Notes

Turolla • September 2016

76M 77C 50C


99Y 55K
33M 100Y

66M
88Y
Local address

Italy
Orange - CMYK 99%Y 76%M
Grey - CMYK 44% Black

Via Natale Salieri, 33-35


40024 Castel San Pietro Terme
Bologna, Italia
Phone: +39 051 6054 411

U.S.A.
2800 East 13th Street
Ames, IA 50010, USA
Phone: +1 515 239 6677

E-mail: turollaocg@turollaocg.com
www.turollaocg.com

You might also like