Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Crouzet Millenium3 Brochure en

Download as pdf or txt
Download as pdf or txt
You are on page 1of 19

■ Extensive ranges

■ User-friendly software

■ Wide choice
of accessories

Standard & Custom

Concentrated performance

www.crouzet.com

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
DISCOVER
The Millenium 3 logic controller
a wealth of functions from the simplest to the
most sophisticated for all installations

What is a logic controller?


A logic controller is a programmable module. It can be used to control Public lighting
and monitor a set of conditions according to the state of the sensors, the Control of public
lighting to coincide
passing of time and the program created using a software workshop. with sunrise/sunset
in order to save
energy while ensuring
optimum security
levels.

SUNRISE AND SUNSET TIME


Calculate the sunrise and sunset
times

Level Counter Timers Impulse relay Temperature


control controller

Ride-on mower
Safety control of the
cutting unit,
presence of person on
the seat, motor starting,
control of the diesel
pump, cutting blade
rotation, the grass box
position and engine
temperature.

Digital or
adaptive tune
PID regulation
Timers
TEMPERATURE INPUT
HIGH-SPEED COUNTER/
RATEMETER
with external preset
Calculation of
level of liquid in
a tank

External preset Bistable memory - Priority


Up/Down counter assigned to SET or RESET

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
Automatic Opening Stretch Hydraulic
barrier control for wrapping solar
Control of barrier industrial machine heating
opening with sectional doors Control of the motor Automation
automatic detection that unrolls the packing of operation
of vehicles. Function Opening control for
doors and associated film. Controls cutting and heating
for selecting opening of the film after heat regulation,
times/days. security devices for
restricting access, sealing and monitors remote management
synchronisation the duration of the of the installation.
between the various motor cycles.
UP/DOWN COUNTER doors.
Up/Down counter
with external preset TEMPERATURE CONTROL
(pressure or other)
GRAFCET SFC FUNCTIONS
For sequential automation systems
BOOLEAN OR LOGICAL (Sequential Function Chart)
Create logic equations between
the connected inputs TIMERS
A/C function - BW function -
B/H function - Li/L function

Heat pump Swimming pool, Mobile solar Field irrigation


management of various fountain, spas panels Field irrigation
parameters such as managing circulation Analysis and control control based on
heating, cooling, fluid pumps, monitoring levels, of solar panel temperature,
temperatures, operation, temperature and water motorisation, humidity, and day/
calendar-based function, conductivity. communication night cycle.
frost protection mode, between panels via
alarm management, etc. Modbus or
Ethernet network.
PUMP MANAGEMENT
FILTRATION Pump switching
Definition of filtration function
WATER RATIO duration depending on the
Water temperature water temperature
control DUAL-AXIS SOLAR TRACKING
CLOCK Optimisation of solar panel
Daily, weekly and yearly time positioning for maximum
programmer efficiency

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
CHOOSE Millenium 3 Standard
Concentrated performance for controlling your current
automation systems with the greatest of ease

Temperature sensors Converters

Ventilation duct Ambient temperature sensor

Temperature Current/voltage
converters converters

Outdoor sensor Thermocouple probe

Power supplies
Modular Switch mode DC/DC
power supplies power supplies power supply
converters
7.5 to 60 W 60 to 240 W

TO
EXCLUSIVE
Functions Millenium 3 Standard
Unique library of 8 models available, compact or
130 function blocks: I/O, logic, calculation, SFC, expandable
control, human-machine interface, etc • With or without display
• Supply voltage: 12 VDC to 230 VAC
• Digital and/or analog I/O
21 new function blocks

Reduced
average Green screen Memory
Random
value
Mathematical
functions • Integrated backlit LCD • Compact range:
display 350 blocks
Angular Timer
cam timer function A
• 4 lines of 18 characters, • Expandable range:
drop-down screen, bar chart 700 blocks

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
Standard

TO
EXCLUSIVE

Serial link Modem communication solutions


and programming
port
• Direct link with remote displays
• PC programming M3MOD STN GSM
• Memory cartridge
• Modem link
• Bluetooth interface Remote displays EXCLUSIVE
TO

Remote screen/keypad
with LED and
function keys

Semi-graphic
remote display

Touch panel

And numerous
accessories
Sandwich Termination
extensions extensions Memory Bluetooth Potentiometer
Digital I/O Digital I/O cartridge interface
• 10 additional I/O • 6/10/14 additional I/O
• Supply voltages: • Supply voltages:
24 VAC - 24 VDC - 12 VDC - 24 VDC - 24 VAC -
100  240 VAC 100  240 VAC
Faceplates Removable
Modbus/Ethernet Analog I/O connectors kit
communication • 4 additional I/O
extension
• 2 x 8 read/write words
• Supply voltage: 24 VDC Actuators
• Supply voltage: 24 VDC and Interfaces

DC Brushless motor Pneumatic island

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
CHOOSE Millenium 3 Custom

All the performance of the


Millenium 3 Standard,
with even more...

+ customisation
Can feature your company logo

+ memory + comfort + adaptations


Up to 700 blocks can be combined Blue screen for • Specific I/O characteristics
to create an unlimited series of improved legibility • Modification of power supplies
applications
• Resin versions
• Customised connections
• Bespoke products
• Dedicated application-specific function blocks

+ resistance + flexibility
Extended temperature withstand: -20°C to
+70°C enables the Millenium 3 to be used “Bare board” versions
in more severe environments Easily integrated into an
existing casing or system
“Resin board” versions (mother/daughter
Solutions which can resist harsh boards)
environments (vibrations, shocks,
damp or confined environments,
non-ventilated equipment, etc)
Extended temperature withstand:
-30°C to +70°C

www.crouzet.com

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
Custom

+ “application-specific”solutions + functions
• Water quality management: (pH, ORP, conductivity) needed to 12 new Custom C function blocks suitable for
control water quality in swimming pools, spas, fountains, ponds, etc. different application areas (defrost, temperature
control, solar tracking)

Ambient NTC Defrost


brightness function

Adaptive tune Swimming


PID regulation pool filtration
• Temperature Control: direct control of probes
without the need for a converter

+ communicating + accessories
“Plug and Play” extension for XN07 communication
enabling communication between up to six Millenium 3 units

pH-ORP probe
Max distance: 1000 m
Light sensor

Temperature probe

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
PROGRAM
A real “software workshop” to optimise
your design process

Free
The Millenium 3 programming software
(M3 SOFT) can be downloaded free of
charge from our website.

www.crouzet.com

Simple
Intuitive
Users do not need any particular knowledge of programming. They can easily teach
themselves with the help of the software. Program operation is simulated accurately.

Quick to get started


For quick, simple programming, the Millenium 3 software provides access to dedicated application-
specific functions such as: pump switching, PID regulation, movement, pressure, level and flow.

User-friendly and ergonomic


Software workshop
Graphic and customisable.

Function blocks
The principle of programming using function blocks (FBD) is child's play in the form proposed by the Millenium 3
software workshop (little coloured icons), virtual wiring.
Help associated with each function block available at the click of a button.

Programming language
You can choose between: LD (Ladder Diagram) and FBD (Function Block Diagram)/Grafcet SFC (Sequential Flow Chart).
The Grafcet language is integrated directly in the function block library.

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
User-definable
Language
You can choose which language to work in: English, French, Italian, German or Spanish.

Creation of macros
You can group your function blocks so as to create macros and thus simplify your programs.
The macros can be locked with a password.

Complete
“Standard” function blocks
All the generic functions: counting, timing, comparison, display,
sin/cos, etc are also available.

“Application-specific” function
blocks
Prioritises dedicated functions:
pump switching, PID regulation, movement,
pressure, level, flow, etc.

Reassuring
Error signalling
Benefit from the “foolproofing” principle: when the slightest data entry error is
made, it flags the incorrect item in red.

“Software” compatibility
You can retrieve any programs you have previously created
on a Millenium 2 directly in the Millenium 3 version.

Safety of programming
You can check your installation as you go along
at each stage of programming.
Optional program password protection
(several levels) or customised protection (FBD key).

Data backup
Without powering up the machine, you can keep
your data for 10 years.

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
PROGRAM
3 operating modes for programming with complete reliability

Edit
 Select the function block Features
 Slide it onto the work area • Creation of macros
 Define the parameters • Password protection of your program
 Connect the blocks together • Display of dependencies between blocks
 Edit a supervision window • Display of a parameter summary table
• Preview of function blocks by theme
• Program very easy to read
• Online help for each function block
Simulation
Check the program you have just Features
created runs correctly, in virtual mode • Simulation in the event of a power failure
(disconnected from the equipment)
• Simulation of program timing
• Analog variables can be modified on your computer via the
Millenium's virtual screen
• Setpoint modification on the virtual screen
• Accurate simulation
• Time-based jump event without changing the time on your PC

Monitoring
Debug your application Features
in realistic conditions • View the machine operation on your PC in real time
• Optimised user interface (Bar chart)
• Program parameters defined directly via the human-machine
interface (keypad)
• Progressive debugging, validating each part of the application
in turn

Display your installation


running in real time.

10
10

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
Blocks can be wired in wiring Move one or more blocks
mode or text mode without disconnecting the wires

Choice of programming Clarity of the Customised password


language work area protection

With the M3 SOFT program, you can take advantage of unrivalled programming flexibility and a huge
processing capacity (up to 700 blocks).

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
USE
Extremely “sociable” and intelligent,
it can adapt to any environment

Operator dialogue
Programmable touch panel
 Can be connected directly to the Millenium 3
 3 backlighting colours: green, orange, red
 Screen size: 3.5"
 Graphic resolution: 320 x 240 pixels
 Fast program transfer with USB cable
Very bright and compact, it is a truly ergonomic display.
Information can be entered directly on the screen using
the touch-sensitive interface.

Numerous functions:
• Alarm management
• Trend management
• Recipe management
• Program backup

Memory cartridge
For loading your applications
and updating the on-board
software (Firmware)

Bluetooth interface USB connection Networking


Wireless “Bluetooth” connection Direct connection Connect your equipment and
for installations that are hard to access to a PC via USB your supervision systems
using Modbus and Ethernet
communication extensions

Share information with


other Millenium units

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
Communicate
“Plug and Play” modem
communication solutions
• Monitor and control your installation remotely
• Alarm notification via SMS/e-mail or on a PC
using Millenium 3 alarm software
• Option of changing the setpoints and values
remotely

Millenium Web Server


• Remote supervision and monitoring from any system with an
Internet browser
• Intuitive programming of supervision pages
• Automatic generation of web pages (up to 20 pages)
• Automatic alerts
• Analog (temperatures, etc)
or digital (alarms, etc)
with text-based
data evaluation
using spreadsheets.

Max distance: 1000 m

Rugghölzli 2 Tel. +41 (0)56 222 38 18 mailbox@sentronic.com


Produkte, Support und Service CH - 5453 Busslingen Fax +41 (0)56 222 10 12 www.sentronic.com
Millenium 3 Standard* selection guide
Starter kits
Type Part number Supply Inputs Outputs
Compact range
KIT12 88970080 24 V DC 8 digital (of which 4 are analog) 4 x 8 A relay

88970081 100 V  240 V AC 8 digital 4 x 8 A relay

KIT20 88970082 24 V DC 12 digital (of which 6 are analog) 8 x 8 A relay

88970083 100 V  240 V AC 12 digital 8 x 8 A relay

Expandable range
KIT26 88970084 24 V DC 16 digital (of which 6 are analog) 10 relays, of which 8 are 8 A and 2 are 5 A

88970085 100 V  240 V AC 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A

Compact range
Type Part number Supply Inputs Outputs
With display
CD12 88970041 24 V DC 8 digital (of which 4 are analog) 4 x 8 A relay
88970042 24 V DC 8 digital (of which 4 are analog) 4 solid state 0.5 A (of which 1 is PWM)
88970043 100 V  240 V AC 8 digital 4 x 8 A relay
88970044 24 V AC 8 digital 4 x 8 A relay
88970045 12 V DC 8 digital (of which 4 are analog) 4 x 8 A relay
CD20 88970051 24 V DC 12 digital (of which 6 are analog) 8 x 8 A relay
88970052 24 V DC 12 digital (of which 6 are analog) 8 solid state 0.5 A (of which 4 are PWM)
88970053 100 V  240 V AC 12 digital 8 x 8 A relay
88970054 24 V AC 12 digital 8 x 8 A relay
88970055 12 V DC 12 digital (of which 6 are analog) 8 x 8 A relay
Without display
CB12 88970021 24 V DC 8 digital (of which 4 are analog) 4 x 8 A relay
88970023 100 V  240 V AC 8 digital 4 x 8 A relay
88970024 24 V AC 8 digital 4 x 8 A relay
88970840 12 V DC 8 digital (of which 4 are analog) 4 solid state 0.5 A (of which 1 is PWM)
CB20 88970031 24 V DC 12 digital (of which 6 are analog) 8 x 8 A relay
88970806 24 V DC 12 digital (of which 6 are analog) 8 solid state 0.5 A (of which 4 are PWM)
88970033 100 V  240 V AC 12 digital 8 x 8 A relay
88970034 24 V AC 12 digital 8 x 8 A relay

Expandable range
Type Part number Supply Inputs Outputs
With display
XD10 88970141 24 V DC 6 digital (of which 4 are analog) 4 x 8 A relay
88970142 24 V DC 6 digital (of which 4 are analog) 4 solid state 0.5 A (of which 1 is PWM)
88970143 100 V  240 V AC 6 digital 4 x 8 A relay
88970144 24 V AC 6 digital 4 x 8 A relay
XD26 88970161 24 V DC 16 digital (of which 6 are analog) 10 relays, of which 8 are 8 A and 2 are 5 A
88970162 24 V DC 16 digital (of which 6 are analog) 10 solid state 0.5 A (of which 4 are PWM)
88970163 100 V  240 V AC 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A
88970164 24 V AC 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A
88970165 12 V DC 16 digital (of which 6 are analog) 10 relays, of which 8 are 8 A and 2 are 5 A
88970814 12 V DC 16 digital (of which 6 are analog) 10 solid state 0.5 A (of which 4 are PWM)
Without display
XB10 88970131 24 V DC 6 digital (of which 4 are analog) 4 x 8 A relay
88970132 24 V DC 6 digital (of which 4 are analog) 4 solid state 0.5 A (of which 1 is PWM)
88970133 100 V  240 V AC 6 digital 4 x 8 A relay
88970134 24 V AC 6 digital 4 x 8 A relay
XB26 88970151 24 V DC 16 digital (of which 6 are analog) 10 relays, of which 8 are 8 A and 2 are 5 A
88970152 24 V DC 16 digital (of which 6 are analog) 10 solid state 0.5 A (of which 4 are PWM)
88970153 100 V  240 V AC 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A
88970154 24 V AC 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A
88970155 12 V DC 16 digital (of which 6 are analog) 10 relays, of which 8 are 8 A and 2 are 5 A

“Sandwich” extensions
Type Part number Supply Inputs Outputs
Digital
XE10 88970321 Via the 24 V DC controller 6 digital 4 x 5 A relays, 1 of which is a changeover relay
88970323 100 V  240 V AC 6 digital 4 x 5 A relays, 1 of which is a changeover relay
88970324 24 V AC 6 digital 4 x 5 A relays, 1 of which is a changeover relay
Communication
XN05 88970270 Via the 24 V DC controller Type - Ethernet Modbus TCP protocol (server)
“Read: 8 - Read/Write: 8 Clock: 4 - Status: 1”

XN06 88972250 Via the 24 V DC controller Type - Modbus RS-485 (Slave)


“Read: 8 - Read/Write: 8 Clock: 4 - Status: 1”

14 * All accessories and Millenium 3 Standard extensions are compatible with Millenium 3 Custom
Termination extensions
Type Part number Supply Inputs Outputs
Digital
Xr06 88970211 Via the 24 V DC controller 4 digital 2 x 8 A relay
88970213 Via the 100 V  240 V AC controller 4 digital 2 x 8 A relay
88970214 Via the 24 V AC controller 4 digital 2 x 8 A relay
88970215 Via the 12 V DC controller 4 digital 2 x 8 A relay
Xr10 88970221 Via the 24 V DC controller 6 digital 4 x 8 A relay
88970223 Via the 100 V  240 V AC controller 6 digital 4 x 8 A relay
88970224 Via the 24 V AC controller 6 digital 4 x 8 A relay
88970225 Via the 12 V DC controller 6 digital 4 x 8 A relay
Xr14 88970231 Via the 24 V DC controller 8 digital 6 relays, of which 4 are 8 A and 2 are 5 A
88970233 Via the 100 V  240 V AC controller 8 digital 6 relays, of which 4 are 8 A and 2 are 5 A
88970234 Via the 24 V AC controller 8 digital 6 relays, of which 4 are 8 A and 2 are 5 A
88970235 Via the 12 V DC controller 8 digital 6 relays, of which 4 are 8 A and 2 are 5 A
Analog
XA04 88970241 Via the 24 V DC controller 1 analog (0-10 V/0-20 mA) 2 analog (0-10 V/PWM)
1 analog (0-10 V/0-20 mA/Pt100)

Communication solutions
Type Part number Supply Name
modem
m3 mOD 88970117 12-24 V DC Modem communication interface

STN 88970118 12-24 V DC STN modem for wired transmission networks

gSm 88970119 12-24 V DC GSM modem for wireless networks (Quad-Band 850/900/1800/1900 MHz)

Web Server
XC10 88950124 24 V DC The Millenium Web Server solution comprises: the Web Server module + 1 program for setting the
supervision page parameters (any Internet browser can be used)

Power supplies
Type Part number Input voltage Nominal output voltage Nominal power Nominal output current
modular casings < 60W
PS 88950303 100 V  240 V AC 24 V DC (22.8 V-28.8 V) 7.5 W 0.3 A
88950304 100 V  240 V AC 24 V DC (22.8 V-28.8 V) 15 W 0.6 A
88950305 100 V  240 V AC 5 V DC (4.75 V-6.25 V) 20 W 4A
88950306 100 V  240 V AC 12 V DC (11.4 V-15 V) 24 W 2A
88950307 100 V  240 V AC 24 V DC (22.8 V-28.8 V) 30 W 1.2 A
88950302 100 V  240 V AC 24 V DC (22.8 V-28.8 V) 60 W 2.5 A
DC/DC converters
PS 88950320 9…18 V DC 12 V DC (11.8 V-12.2 V) 10 W 0.8 A

88950321 9…36 V DC 24 V DC (23.5 V-24.5 V) (6-10 W for input voltage of 9-16 V) 0.4 A

metal casings > 60W


PS 89450122 100 V  240 V AC 12 V DC 100 W 8.3 A

89450222 100 V  240 V AC 24 V DC 100 W 4.2 A

89450232 115 V/230 V AC 24 V DC 150 W 6.2 A

89450242 115 V/230 V AC 24 V DC 240 W 10 A

26450100 Snap-on plate for 35 mm DIN rail

26450101 Mounting bracket

Accessories
Type Part number Name
Programming tools and software

AS 88970111 Multilingual programming software

88970116 Alarm management software

88970108 EEPROM memory cartridge for transferring/saving programs

Connection accessories

PA 88970102 3 m serial link cable: PC  Millenium 3

88970104 Millenium 3  Bluetooth interface (class A 10 m)

88970109 3 m USB link cable: PC  Millenium 3

88970110 Bluetooth  USB adaptor (class A 10 m)

88970123 1.80 m serial link cable: DB9/DB9

* All accessories and Millenium 3 Standard extensions are compatible with Millenium 3 Custom 15
Type Part number Name Supply Temperature range
Analog temperature transmitters
AS 89750146 Copper protective sleeve - -

89750147 316 stainless steel protective sleeve - -

89750150 Ambient temperature sensor (0-10 V) 24 V DC -10  +40°C

89750151 Ventilation duct (0-10 V) 24 V DC -10  +60°C

89750152 Outdoor sensor (0-10 V) 24 V DC -10  +40°C

89750153 Remote/submersible probe (0-10 V) 24 V DC -10  +150°C

89750155 Remote/submersible probe (0-10 V) 24 V DC -40  +20°C

18373112 Heat transfer compound - -

Type Part number Name Temperature


Pt100/Thermocouple probes
AS 79696030 Thermocouple probe J with nickel-plated brass eyelet Max: 400°C

79696031 Sleeved thermocouple probe J - 304 L stainless steel Max: 600°C

79696032 Thermocouple probe J 316 stainless steel sheath Ø 6 mm Max: 400°C

79696033 Thermocouple probe J 316 stainless steel sheath Ø 5 mm Max: 400°C

79696034 Sleeved thermocouple probe K - 304 stainless steel Max: 1100°C

79696035 Pt100 probe Class B with 316 stainless steel sheath Max: 200°C

79696036 Pt100 probe Class B with 316 stainless steel sheath Max: 400°C

79696037 Pt100 probe Class B with aluminium V6 sheath Max: 200°C

Type Part number Name Supply Inputs Outputs


Signal converters
AC 88950108 0-20 mA/0-10 V input converter - 4 4

88950112 PWM/0-10 V output converter 24 V DC 1 1

Temperature converters
AC 88950150 Input-Converter -20  + 150°C 24 V DC Pt1000 3-wire 0-10 V

88950151 Input-Converter -40  + 40°C 24 V DC Pt100 3-wire 0-10 V

88950152 Input-Converter 0  + 100°C 24 V DC Pt100 3-wire 0-10 V

88950153 Input-Converter 0  + 250°C 24 V DC Pt100 3-wire 0-10 V

88950154 Input-Converter 0  + 300°C 24 V DC Thermocouple J 0-10 V

88950155 Input-Converter 0  + 600°C 24 V DC Thermocouple K 0-10 V

Type Part number Name Supply


Programmable touch panel
rD 88970432 MTP05 - User kit (MTP05, fixing brackets, connectors, MTP <=> M3 cables) 24 V DC
88970434 MTPWIN programming pack (CD, PC <=> MTP05 USB cable) -
88970443 Front panel protective membranes for MTP05 (pack of 10 membranes) -
88970444 Front panel sealing kits for MTP05 (pack of 10 kits) -
88970445 Backup battery for MTP05 -
remote alphanumeric displays (modbus communication)

rD 88970421 Runtime kit: Three-colour screen + XN06 Modbus extension 24 V DC

88970422 Runtime kit: Monochrome screen + XN06 Modbus extension 24 V DC

88970844 Programming kit: Monochrome screen + XN06 Modbus extension + CD + cables 24 V DC

88970849 Programming kit: Three-colour screen + XN06 Modbus extension + CD + cables 24 V DC


remote LCD displays/keypads (direct link with millenium 3 via cable)
rD 88970410 Remote LCD screen/keypad 24 V DC
88970411 Remote LCD screen/keypad + 4 function keys + 4 LEDs 24 V DC
88970412 Kit with remote LCD screen/keypad + cable 24 V DC
88970413 Remote LCD screen/keypad + 4 function keys + 4 LEDs + cable kit 24 V DC
88970414 IP65 protection accessory for display/keypad 24 V DC
Connection accessories
rD 88950400 Display with 4 x 14 mm red digits 24 V DC

EP 88950109 External potentiometer for value adjustment (4700 Ohm) 30 V DC max

Type Part number Name


removable connectors
mA 88970310 Removable kit 12 I/O
88970311 Removable kit 20 I/O
88970312 Removable kit 26 I/O
Faceplates

mA 88970809 IP40 faceplate


88970810 IP40 faceplate
89750160 IP67 sealed faceplate adaptor (76.5 mm)
89750161 IP67 sealed faceplate adaptor (147.5 mm)
89750162 IP67 sealed faceplate adaptor (248.5 mm)

* All accessories and Millenium 3 Standard extensions are compatible with Millenium 3 Custom
Millenium 3 Custom* selection guide
Custom compact range
Type Part number Supply Inputs Outputs
With display
CD12 88974041 24 V DC 8 digital (of which 4 are analog) 4 x 8 A relay
88974042 24 V DC 8 digital (of which 4 are analog) 4 solid state 0.5 A (of which 1 is PWM)
88974043 100 V  240 V AC 8 digital 4 x 8 A relay
88974044 24 V AC 8 digital 4 x 8 A relay
88974045 12 V DC 8 digital (of which 4 are analog) 4 x 8 A relay
CD20 88974051 24 V DC 12 digital (of which 6 are analog) 8 x 8 A relay
88974052 24 V DC 12 digital (of which 6 are analog) 8 solid state 0.5 A (of which 4 are PWM)
88974053 100 V  240 V AC 12 digital 8 x 8 A relay
88974054 24 V AC 12 digital 8 x 8 A relay
88974055 12 V DC 12 digital (of which 6 are analog) 8 x 8 A relay
Without display
CB12 88974021 24 V DC 8 digital (of which 4 are analog) 4 x 8 A relay
88974023 100 V  240 V AC 8 digital 4 x 8 A relay
88974024 24 V AC 8 digital 4 x 8 A relay
CB20 88974031 24 V DC 12 digital (of which 6 are analog) 8 x 8 A relay
88974033 100 V  240 V AC 12 digital 8 x 8 A relay
88974034 24 V AC 12 digital 8 x 8 A relay

Custom expandable range


Type Part number Supply Inputs Outputs
With display
XD10 88974141 24 V DC 6 digital (of which 4 are analog) 4 x 8 A relay
88974142 24 V DC 6 digital (of which 4 are analog) 4 solid state 0.5 A (of which 1 is PWM)
88974143 100 V  240 V AC 6 digital 4 x 8 A relay
88974144 24 V AC 6 digital 4 x 8 A relay
XD26 88974161 24 V DC 16 digital (of which 6 are analog) 10 relays, of which 8 are 8 A and 2 are 5 A
88974162 24 V DC 16 digital (of which 6 are analog) 10 solid state 0.5 A (of which 4 are PWM)
88974163 100 V  240 V AC 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A
88974164 24 V AC 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A
88974165 12 V DC 16 digital (of which 6 are analog) 10 relays, of which 8 are 8 A and 2 are 5 A
Without display
XB10 88974131 24 V DC 6 digital (of which 4 are analog) 4 x 8 A relay
88974132 24 V DC 6 digital (of which 4 are analog) 4 solid state 0.5 A (of which 1 is PWM)
88974133 100 V  240 V AC 6 digital 4 x 8 A relay
88974134 24 V AC 6 digital 4 x 8 A relay
XB26 88974151 24 V DC 16 digital (of which 6 are analog) 10 relays, of which 8 are 8 A and 2 are 5 A
88974152 24 V DC 16 digital (of which 6 are analog) 10 solid state 0.5 A (of which 4 are PWM)
88974153 100 V  240 V AC 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A
88974154 24 V AC 16 digital 10 relays, of which 8 are 8 A and 2 are 5 A
88974155 12 V DC 16 digital (of which 6 are analog) 10 relays, of which 8 are 8 A and 2 are 5 A

Custom “sandwich” extensions


Type Part number Supply Name
Communication
XN07 88974250 Via the 24 V DC controller Millenium exchange unit (Master)
Enables communication between up to six Millenium 3 units

Custom “application-specific” analog termination extensions


Type Part number Supply Inputs Outputs

XA03 88970800 With 24 V DC power base 3 Pt 100 (-25°C  + 125°C)

XA04W 88972805 With 24 V DC power base 1 Pt 100 (0°C-50°C), 1 output 24 V DC ± 5% 0.6 W


1 pH (0-14), 1 ORP (0-1000 mV), to supply the 4-20 mA sensor
1 current (4-20 mA)

Custom accessories
Type Part number Name measurement range

ph 89750170 pH probe with BNC connector 3 m -

89750171 pH probe with ferrules 3 m -

OrP 89750172 ORP probe with BNC connector 3 m -

89750173 ORP probe with ferrules 3 m -

AS 89750174 PVC NTC probe for Millenium 3 (24 V DC, ± 10%) -25°C  + 85°C
89750180 NTC probe (pack of 10) for Millenium 3 (24 V DC, ± 10%) -25°C  + 85°C
89750182 305 stainless steel NTC probe for Millenium 3 (24 V DC, ± 10%) -35°C  + 120°C
89750185 POM NTC probe (pack of 25) for Millenium 3 (24 V DC, ± 10%) -20°C  + 105°C
89750186 Silicon NTC probe for Millenium 3 (24 V DC, ± 10%) 0°C  + 180°C
89750183 LDR1 light sensor for Millenium 3 (24 V DC, ± 10%) 10 Lux  3000 Lux

Other versions available on the website

Bare board versions Resin board versions www.crouzet.com


* All accessories and Millenium 3 Standard extensions are compatible with Millenium 3 Custom
Glossary of function blocks
INPUTS OUTPUTS gain
INPUT OUT Converts an analog value by changing the scale and datum point

10-bit analog multiplication and/or Division


0/10V analog input extension output Simple operations on integers: Multiplication and/or Division

Digital output multiplexing


10-bit analog Multiplexing two input channels on an output
extension input
CONTrOL
PWm output Bistable
12-bit analog
extension input Modifies the state of the output on each rising edge (change from inactive
hmI to active) of the CONTROL input
Comparison
Digital input LCD screen backlighting Compares two analog values using the operators
output =, >, <, >=, <=, =/=.
Compare in Zone comparison
PrOg Compares a value between two setpoints
Filtered analog input (the min and max values delimit the zone)
Integer type output
min max
Saves the minimum value and the maximum value of a signal
Filtered digital input
Preset Up/Down counter
LOgIC Preset Up/Down counter
hmI LOgIC
Preset hour counter
Button A Logical “AND” with 4 inputs Preset hour counter (Hours Minutes)
Set/reset
Logical “NAND” with Bistable memory - Priority given to either SET or RESET
Button B 4 inputs depending on the function configuration
Time programmer
Logical “NOr” with Programmer of time slots during which it will be possible to execute
ESCAPE (ESC) button 4 inputs actions (Day/week/month/year)
Timer
Logical “NOT” Wide choice of timer functions (A/C, BW, B/H, Li/L, totaliser)
mINUS BUTTON
Up/Down counter
Count up or count down from a preset value,
Logical “Or” with 4 inputs the result of a calculation external to the function
OK button hmI
Display on the screen
“XOr” with 2 inputs Display text, a date, a time or a value
PLUS button in digital format on the LCD display
message
CONTrOL Send alarm messages to mobile phones, to the Millenium 3 Alarm tool or
grAFCET SFC to e-mail addresses via the M3MOD communication interface
SFC
1 second clock SL In
Transmit data via a programming port to memory space in the controller's
Convergence to “AND” fixed addresses
PrOg SL Out
Send data stored in the controller's fixed addresses
Divergence to “AND” to other devices, via a programming port
“OFF” constant
Text
Display of text and/or numerical values
SFC initial step (current value, preset value, etc)
“ON” constant LOgIC
Boolean equation
Convergence to “Or” Creation of logic equations according to the combination of inputs
Integer type input PrOg
Or Divergence Step Archive
Saves two values simultaneously with the information
Numerical constant relating to their time-stamping
resettable initial step Controller status
Allows the user to access the controller status and modify the behaviour of
its FBD and/or SFC program depending on these states
Summertime SFC step Standard macro
Used to generate macros

FBD FUNCTIONS FBD_C FUNCTIONS


APP APP
Schmitt trigger Analog PID regulation (8 bits)
Monitors an analog value in relation to two thresholds Temperature control (pressure or other) with 8-bit analog output

Cam timer Angular cam timer


Controls a group of 8 integral cam wheels Cam timer with the angle made by the cams as control
input
CALCUL
Flow
Addition/Subtraction Used to calculate the flow of a liquid in a pipe using a differential pressure
Simple operations on integers: addition/subtraction element or by measuring the dynamic pressure
Level
Bin/Dec Used to calculate the level of liquid in an open or closed tank, with or
Makes up an integer type output (16 bits) from 16-bit type inputs without constant density, using pressure sensors

Dec/Bin Pressure gain


Breaks down an integer type input (16 bits) into 16-bit type outputs Used to create the interface between pressure sensors (Manual mode)
or Crouzet pressure sensors (Automatic mode) and the Millenium
Pump rotation Storage
Tank management with pump rotation Calculates a running mean of the stored values

PWm PID regulation (8 bits) Yes Bit


Temperature control (pressure or other) with 8-bit digital output Used to copy the input to the output
(very useful when using macros)
Single-axis solar tracking Yes Word
Calculates the sun's position so that a sun dial can be placed Used to copy the input to the output
(very useful when using macros)
Sunrise/sunset SFC
Calculates the sunrise and sunset time in relation
to the latitude and longitude read on the function block inputs motor multiplexer
CALCUL Combines the motor control signals produced by two linked
MOVE SFC steps
ADD/SUB math function
Simple operations on integers: addition/subtraction move SFC Step
Used to set up a move step for a motor controlled by the PLC
Demultiplexer to a position specified on the TARGET input
Demultiplexing on integers. Used to direct the value of the input
to one of the 4 OUTPUTS Wait SFC Step
multiplexer Used to set up a wait phase or step for a PLC or a device
Performs multiplexing on MOT inputs. It is used to route the value of one
of the inputs selected by the ADDRESS input to the output
FBD_C Custom FUNCTIONS
Sin/Cos APP
Used to calculate the cos and sin of an angle between 0° and 90°.
Analog PID regulation (Auto-tuning)
Square root Analog PID (Proportional Integral Derivative)
Calculates the square root of the number present as an regulation (auto-tuning)
input with accuracy to two decimal points
CONTrOL NTC 1
Temperature measurement.
Fast count Function designed for NTC1 probes (-25 to +85°C)
Used to count the pulses arriving at input I1
at rates in excess of one pulse every 10 ms NTC 2
high speed count Temperature measurement.
Used to count the pulses arriving at inputs I1 and I2 of a controller Function designed for NTC2 probes (-35°C to +120°C)
powered by a DC supply, at rates in excess of one pulse every 6 ms
NTC3
Temperature measurement.
hL Switch Function designed for NTC3 probes (0°C to +200°C)
Comparison of a value against 5 thresholds
mULTI COmPArE Defrost
Used to activate the output corresponding Defrost cycle management
to the value present on the “Value” input
Water ratio
reduced average Used to modulate the heating water temperature according to the
Calculates the average of a number of configured values atmospheric conditions. The function uses automatic regulation
by deleting the minimum and maximum values depending on the temperature outdoors called the temperature curve
or “water ratio”
Timer A
Used to delay actions for a predefined time LUX-I
Measures the light level. Function designed for photoresistors and internal
Timer/Set reset light meters (0 to 8000 Lux)
Triggers operation of a particular device Dual-axis solar tracking
at a fixed time for a period set by the user Calculates the sun's position so that a sun dial can be placed.
Weekly Time Prog This positioning depends on the two angles calculated by the
Time programmer which is used to enable time slots function: the elevation angle and azimuth angle
during which it will be possible to execute actions Swimming pool filtration
hmI This function gives a filtration time in relation
menu scrolling to the water temperature
Used to activate one of the digital outputs. This function can be useful for Twilight
menu scrolling if displays are wired as outputs This function calculates the sunrise and sunset times and also the twilight
SLin S (saved) times in relation to the latitude and longitude read on the function block
Used to transmit data via a programming port to memory space in inputs.
the controller's fixed addresses. Data is protected in the event of CALC
disconnection of the controller power supply SPLIT 16 bits into 2
PrOg This function is used to split a 16-bit word into two 16-bit words
with values between 0 and 255
Logical “AND” with 2 inputs
Logical AND with 2 inputs SPLIT 16 bits into 4
This function is used to split a 16-bit word into four 16-bit words
Logical “AND” with 6 inputs with values between 0 and 15
Logical AND with 6 inputs. If all the inputs are active or not connected,
the output is active. If at least one input is inactive, the output is inactive. Transfer time function
This function is a correspondence table for the
Bit multiplexer Minutes operating time and the Y output
Copies the selected input to the outputs Q and /Q
Transfer time function 50 values
Boolean with 6 inputs/2 outputs This function is a correspondence table for the Minutes
Boolean equations with six inputs and two outputs operating time and the Y output (50 values)
Transfer function
Logical “Or” with 2 inputs This function is a table of correspondence between the X input
Logical OR with 2 inputs and the Y output
Logical “Or” with 6 inputs Transfer function 50 values
If at least one input is active, the output is active. This function is a table of correspondence between
If all the inputs are inactive or not connected, the output is inactive. the X input and the Y output (50 values)
PrOg
Word shift
hour minute Shifts the 16-bit words on each rising edge of the clock
Displays the controller time (H/Min)
hmI
hr min Converter
Converts a time period in the “hour: minute” format to minutes and vice Alarm
versa Controls 10 alarm levels and sends a code in series to a digital output,
connected to a modem digital input, to generate an SMS, for example
Archive
Used to save a value between -32768 and 32767 LOgIC

random Shift register


This function provides a pseudo-random value between the Shifts the bits of a 16-bit word on each rising edge
minimum and maximum values set by the user of the clock

19