Monitoring Relays: Operating Instructions

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

s

Operating Instructions

Monitoring Relays 7UG0


IEC 60947-5-1

Please read and understand these instructions before


installing, operating, or maintaining the equipment.
DANGER
Hazardous voltage can cause death or serious injury.
Disconnect power before working on equipment.
CAUTION
Reliable functioning of the equipment is only
ensured with certified components.
Overvoltage category II
(Refer IEC 60947-1)
NOTICE
This product has been designed for environment A. Use
of this product in environment B may cause unwanted
7UG0 712... 7UG0 818... 7UG0 753... 7UG0 84... electromagnetic disturbances in which case the user may
require to take adequate mitigation measures.

Technical Data

Designation 7UG0 712-1AA20 7UG0 818-1CA20 7UG0 753-1AA20 7UG0 841-1CB20 7UG0 842-1CD20
Type Voltage
Line monitoring relay Earth leakage relay
Monitoring relay
Supply voltage * 415V AC 415V AC 415V AC
1f - 2W, 3f - 4W
3f - 3W 3f - 3W, 3f - 4W 3f - 3W
Operating band 280 - 500 VAC (L-L)
154 - 480 VAC (L-L) 310 - 480 VAC 10mA--30A
160 - 288 VAC (L-N)
Control voltage Built-in Built-in Built-in 110V AC 230V AC
Operating
0 to 50°C
temperature
Trip modes hase Sequence reverse
P Under Voltage Phase Sequence
Phase Missing Over Voltage reverse
Phase Failure trip : Under frequency : 45 - 65Hz Phase Missing
Leakage Current : 10mA - 30A
< 154Vac (L-L) Over frequency : 45 - 65Hz Under Voltage
Phase Imbalance : Phase asymmetry: 5-99.9% Over Voltage
30V fixed
Trip Time delay Instantaneous 0 - 99.9 sec 0.2 - 10 sec 0 - 99.9 sec

7UG0 712…
Terminal connections

LED Indication Chart Timing Diagram

Fail Safe
Parameter Green LED
Relay

Nominal
ON Energised
Condition

Phase reverse/
OFF De-energised
Phase fail

Phase
OFF De-energised
Imbalance

* To be used only for Star point Earthed Supply system

1
7UG0 818…
Terminal connections

LED Indication Chart

Various Conditions Power LED ‘R1’ LED ‘R’ LED

No fault ON OFF OFF

Trip (Relay 1) ON ON OFF

Trip (Relay 2) ON OFF ON

Trip (If programmed for both


ON ON ON
relays)

7UG0 753...
Terminal connections Front panel description for 7UG0 753…
LED Indication Chart

Parameter Green LED Fail Safe Relay


Over voltage setting
2.5 to 25% of 415V
Nominal Condition ON Energised

Trip time delay Phase reverse/ Phase fail OFF De-energised

Under / Over Voltage OFF De-energised

Under voltage setting


-2.5 to -25% of 415V
Timing Diagram

7UG0 7, 7UG0 9 7UG0 8…


0.6 Nm 0.5 Nm
5
1 x (0.75... 2.5) mm2
2 x 0.5 to 2 x 1.5 mm2
Solid
5
1 x (0.5... 2.5) mm2
Stranded with 2 x (0.5... 1.5) mm2
end sleeve

7UG0 84…
Terminal connections

Note:
LED Indication Chart
CBCT (Core Balanced Current Transformer) is an accessory to be used with
Various Conditions ‘R1’ LED ‘R2’ LED 7UG0 84...
For single phase applications, only the live and neutral needs to be passed
No fault OFF OFF through the CBCT.
The Earth MUST NOT pass through the CBCT.
Trip The distance between relay and CBCT should be kept as short as possible
ON ON
(if programmed for Relay 1) Use Screen, shielded cable or twisted pair cable between the unit and
CBCT for long distance (Greater than 1m).
Pre-Alarm OFF ON
Type Designation Inner diameter
Trip
ON ON 7UG0 9-96 35mm
(if programmed for both relays)
CBCT 7UG0 9-97 70mm
CBCT error Blinking Blinking
7UG0 9-99 120mm

2
Menu Guide 7UG0 818…

Configuration Menu

Main Menu Sub Menu


Display Default
Description Range Condition
(For 1sec) Value

Display Default
Description Range Condition
(For 1sec) Value
Keys
Or
To scroll through main menu press

Display Default
Description Range Condition Display Default
(For 1sec) Value Description Range Condition
(For 1sec) Value

Display Default
Description Range Condition
(For 1sec) Value

Display Default
Description Range Condition
(For 1sec) Value

Display Default
Description Range Condition
(For 1sec) Value

3
Display Default
Description Range Condition
(For 1sec) Value
Display Default
Description Range Condition
(For 1sec) Value

Display Default
Description Range Condition
(For 1sec) Value

Online Keys

Parameter Symbol
* Average Voltage L1 L2 L3
Voltage (L1-phase) L1
Display Default
(For 1sec)
Description
Value
Range Condition Voltage (L2-phase) L2
Voltage (L3-phase) L3
Voltage (L1-L2 phase) L1 L2
Voltage (L2-L3 phase) L2 L3
Trip Value Setting
Voltage (L1-L3 phase) L1 L3
Frequency Hz
Display Default
Description Range Condition
(For 1sec) Value Phase Asymmetry As %

* For 3P4W system average of L-N voltages is shown.


For 3P3W system average of L-L voltages is shown.

Menu Guide 7UG0 84...

Configuration Menu Sub Menu

Main Menu Sub Menu Online Keys


Display Default
Description Range Condition
(For 1sec) Value
Keys
Or
To scroll through main menu press

Display Default
Description Range Condition
(For 1sec) Value

4
Display Default
Description Range Condition
(For 1sec) Value
Display Default
Description Range Condition
(For 1sec) Value

Display Default
Description Range Condition
(For 1sec) Value

Display Default
Description Range Condition
(For 1sec) Value

Display Default
Description Range Condition
(For 1sec) Value

Trip Value Display


Description
Default
Range Condition
(For 1sec) Value

Display Default
Description Range Condition
(For 1sec) Value

Test & Reset Function


Display
Key Description LED’s Condition
(For 1sec.)

Trip Indication
Reset

Master Password : 753

5
Dimensional drawings

7UG0 7… 7UG0 8…

7UG0 9… (CBCT)

Top View

CBCT
Dimensions (mm)
TYPE
D d H W W1
7UG0996 70 35 96 10 40
7UG0997 107 70 131 10 40
7UG0999 157 120 184 10 40
STD.TOL. 2-3 5-6 - 1.5 - 2 - Front View Side View

Disposal
Siemens product are environment friendly, which PLASTICS: Segregate as per material type for recycling
predominantly consist of recyclable materials. through authorised dealer. Because of the long lifetime of
For disposals we recommend disassembling and separation Siemens products the disposal guidelines may be replaced
into following materials: by other national regulations when taking the product out
METALS: Segregate into Ferrous & Non Ferrous types for of service.
recycling through authorised dealer. The local customer care service is available at any time to
answer disposal-related questions

Customer Care Toll free no. 1800 209 0987 Email: ics.india@siemens.com Order No. 4I-0122-3124480-000 00

Siemens Ltd. Product development is a continuous process. Consequently SACHIN ENTERPRISE


SGR-02-913 the data indicated in this Leaflet is subject to change without
prior notice. For latest issue contact our sales offices.