Machine - Room-Less Elevator Catalogue
Machine - Room-Less Elevator Catalogue
Machine - Room-Less Elevator Catalogue
kr
PASSENGER ELEVATORS
General and MRL(Machine-Room-Less) Type
PASSENGER ELEVATORS - We reserve the right to change designs and specifications for the product development without prior notice. Printed in Korea
CATALOG CODE : C-VPE-E1108 / 2005. 5 / Revision 11
General Type MRL(Machine-Room-Less) Type
The most economical option for residential or midrise commercial building. The highest An innovative new elevator which does not require a separate machine room. Applicable to
efficiency is achieved through the optimal combination of voltage and frequency, the latest and residential or mid-to high rise commercial buildings.
most advanced technology VVVF, of electric power supply to the induction motor.
SE34 SE36
�Ceiling �Ceiling
CD516B (Indirect lighting)/ CD451B/ Acryl / Acryl Lens /
Convective Air Sterilization System Painted Steel (P022)
�W all �W all
Hairline Etched Stainless Steel (SE739), Hairline Etched Stainless Steel (SE1169)
Galaxy Art(AF-G-246)
�Car Doors
�Car Doors Hairline Etched Stainless Steel (SE1169)
Galaxy Art(AF-G-246)
�Operating Panel
�Operating Panel OPP-N240A
OPP-N240A,
�Indicator
OPP-N240W (For the disabled)
Deluxe Type(PI-D600)
�Indicator �Handrail
Deluxe Type(PI-D600)
Stainless Steel 1Pipe(1A)
�Handrail �Entrance Column
Stainless Steel 1Pipe(1A)
Hairline-Finished Stainless Steel
�Entrance Column �Flooring
Hairline-Finished Stainless Steel
Polyvinyl Tile
�Flooring (TN2401C, TN2406C)
Polyvinyl Tile
(TN2211C, TN2401C, TN2412C)
SE35 SE37
�Ceiling �Ceiling
CD249C/ Acryl / Acryl Lens / CD291C/ Lumasite /
Painted Steel (P021) Painted Steel (P021)
�W all �W all
Hairline Etched Stainless Steel (SE1168) Hairline Etched Stainless Steel (SE1177)
�Car Doors �Car Doors
Hairline Etched Stainless Steel (SE1168) Hairline Etched Stainless Steel (SE1177)
�Operating Panel �Operating Panel
OPP-N240A, OPP-N240A,
OPP-N240W (For the disabled) OPP-N240W (For the disabled)
�Indicator �Indicator
Deluxe Type(PI-D600) Deluxe Type(PI-D110)
�Handrail �Handrail
Stainless Steel 1Pipe(1A) Stainless Steel 1Pipe(1R)
�Entrance Column �Entrance Column
Hairline-Finished Stainless Steel Hairline-Finished Stainless Steel
�Flooring �Flooring
Polyvinyl Tile (DTF5311, DTF5906) Polyvinyl Tile ( TN2411C, TN2412C)
Note : Finished product may vary slightly from these prints. Note : Finished product may vary slightly from these prints.
SB20 SB23
�Ceiling �Ceiling
CD451B / Acryl / Acryl Lens / CD513E(Indirect lighting)/
Painted Steel (P021) Painted Steel / Down Light
�W all �W all
Polyvinyl Sheet (ME04 / ME5011) / Hairline Etched Stainless Steel
Aluminium Di-Casting Trim (SE739/SE798/SE799)
�Car Doors �Car Doors
Polyvinyl Sheet (ME04) Hairline Etched Stainless Steel (SE739)
�Operating Panel �Operating Panel
OPP-D240A, OPP-N240,
OPP-N240W (For the disabled) OPP-N240W (For the disabled)
�Handrail �Indicator
Stainless Steel 1Pipe (1A) Deluxe Type(PI-D600)
�Entrance Column �Handrail
Hairline-Finished Stainless Steel Stainless Steel 1Pipe (1R)
�Flooring �Entrance Column
Polyvinyl Tile (86516) Hairline-Finished Stainless Steel
�Flooring
Polyvinyl Tile (RN33019)
SB21 SB24
�Ceiling �Ceiling
CD469B / Acryl / Painted Steel (P017) CD439B / Acryl / Painted Steel (P016)
�W all �W all
Hairline Etched Stainless Steel (SE439) Polyvinyl Sheet (FW234) /
Hairline Etched Stainless Steel (SE1167)
�Car Doors
Hairline Etched Stainless Steel (SE439) �Car Doors
Hairline Etched Stainless Steel (SE1167)
�Operating Panel
OPP-N240, �Operating Panel
OPP-N240W (For the disabled) OPP-D240A,
OPP-N240W (For the disabled)
�Indicator
Deluxe Type(PI-D600) �Handrail
Stainless Steel 1Pipe(1A)
�Handrail
Stainless Steel 1Pipe(1R) �Entrance Column
Hairline-Finished Stainless Steel
�Entrance Column
Hairline-Finished Stainless Steel �Flooring
Polyvinyl Tile (LM3602)
�Flooring
Polyvinyl Tile
(TN2202C, TN2203C, TN2211C)
Note : Finished product may vary slightly from these prints. Note : Finished product may vary slightly from these prints.
JP050PP JP200ESS-01
�Landing Doors �Landing Doors
Painted Steel Sheet (P003) Etched Stainless Steel (EE008)
�Jambs �Jambs
Narrow Jambs in Painted Steel Sheet Full-Wall Jambs in Hairlined Stainless Steel
�Hall Button with Position Indicator �Transom Panel
To be Selected Separately, HIP-D442 (Shown) Hairline-Finished Stainless Steel
�Position Indicator & Hall Button
To be Selected Separately, PI-D110, HPB-442 (shown)
JP100SS JP200ESS-02
�Landing Doors �Landing Doors
Hairline-Finished Stainless Steel Etched Stainless Steel (EE007)
�Jambs �Jambs
Full-Wall Jambs in Hairlined Stainless Steel Full-Wall Jambs in Hairlined Stainless Steel
�Hall Button with Position Indicator �Transom Panel
To be Selected Separately, HIP-D640 (Shown) Hairline-Finished Stainless Steel
�Position Indicator & Hall Button
To be Selected Separately, PI-D600, HPB-240 (Shown)
JP200
P : Painted Steel Sheet
L : Plastic-Laminated Steel Sheet (*)
S : Hairline-Finished Stainless Steel (*)
E : (Hairline) Etched Stainless Steel (*) Note *: optional
AUTO
AUTO FULL HYUNDAI
FULL
PI-S100 (LED Segment Type) PI-D600 (Dot Matrix Type) PI-D200 (Dot Matrix Type)
(LED Segment Type : PI-S200)
PASSENGER
28 PERSONS
1800 kg
AUTO
FULL
AUTO
AUTO FULL HYUNDAI
EMERGENCY FULL
CALL
HALL BUTTONS
TYPE OF BUTTONS
PAINT COLOR
TN2211C TN2601C TN2604C
Note : Finished product may vary slightly from these prints.
P003 (2.3Y 8.5/2.5) P006 (2.5GY 7/12) P008 (8.5YR 7.1/12.5) P009 (4.5B 7.8/2.0)
HANDRAIL W ood designs are available.
A Min.1100
Min.2000
Maintenance Door (By others)
Overhead (OH)
(By others) Control Traction
900(W)×1900(H) Panel Machine
Floor with CA
CB
Y
Overhead (OH)
CB
Y
B
Top Floor(FH)
Control
Control
Min.2600
Panel
Panel
Panel
Panel
Panel
OP
OP
Travel (TR)
Panel
Panel
Speed Overhead Pit
530 OP (m/min) (OH) (PP)
Power Distribution
60 FH+2000 1500
Travel (TR)
Board(By others)
90 FH+2000 1800
(Unit : mm) 105 FH+2000 2100
Receptacle
Notes : 1, Above dimensions are applied in (By others)
Speed Overhead Pit case car height is 2500mm. 120 FH+2000 2100
(m/min) (OH) (PP) (Car internal height is 2300mm.)
60 3800 1500 2, Above shown is minimum size.
SPACE SAVERⅠ-T
(Permanent Magnet Synchronous Motor)
Plan of Hoistway Section of Hoistway Entrance Design Structural opening of Entrance
Hook(By others)
X cL OF CAR
A
30
Overhead(OH)
700
Steel Bar for 150
CA Fixing Jambs
� 9×6EA (By others)
Y
Hall Button
CB
with
Jamb Height(JH)
500
Indicator
700
Control
Control
Control
Control
Control
Floor with
Panel
Panel
Control Panel
Total Height(TH)
Panel
Panel
Panel
Power Distribution OP
Board(By others) 530
1000
CP Clear Opening (OP) 30 Concrete Opening
530
700
Clear Opening Clear Opening
Finished +CP+100 +100
Travel(TR)
Floor Level 2 2
(By others)
Ent. Height(EH)
Traction
Floor without Machine
ABOUT 600
Pit Depth(PP)
(Unit : mm)
Notes : Above dimensions are applied
Speed Overhead Pit cL OF CAR
(m/min) (OH) (PP) Travel in case car height is 2500mm.
Transom Panel
(Car internal height is 2300mm)
Drainage (∅ 50)
45 3800 1400 MAX Ladder Waterproof
(By others)
Position
41000 Receptacle (By others) Finish(By others) Indicator
60 3800 1500
(By others)
700
Steel Bar for
(Unit : mm)
Fixing Jambs
Jamb Height(JH)
Speed Motor
300
700
45 2.6
8 550 800 1400 × 1030 1460 × 1185 1900 1700
60 3.4
45 2.8
9 600 800 1400 × 1100 1460 × 1255 1900 1750
CP Clear Opening (OP) 30
60 3.7
1000
530 Concrete Opening
700
45 3.3 Finished Clear Opening Clear Opening
10 700 800 1400 × 1250 1460 × 1405 1900 1950 Floor Level +CP+100 +100
2 2
60 4.3 (By others)
45 3.5
11 750 800 1400 × 1350 1460 × 1505 1900 2050
60 4.6
45 4.6
15 1000 900 1600 × 1500 1660 × 1655 2150 2200
60 6.2
Notes : 1. The capacity in persons is calculated at 68kg/person. (EN81 75kg/person)
2. For applicable dimensions on the speed of 90 m/min, 105m/min or 17 persons, consult Hyundai.
Plan of Hoistway & Machine Room Section of Hoistway Standard Dimensions & Reactions
(Unit : mm)
MX1
Height(MH)
M/C Room
A Cinder
(By others)
Speed Capacity M/C Room
Concrete Min.150 Opening Internal External 1Car 2Cars 3Cars Depth 1Car 2Cars 3Cars Depth Reaction(kg)
R1 (By others) (m/min)
Persons kg OP CA×CB A×B X1 X2 X3 Y MX1 MX2 MX3 MY R1 R2
window
window
window
window
Gallerywindow
R2 R1
others)
others)
others)
others)
others)
(Byothers)
6 450 800 1400× 850 1460×1005 1800 3700 5600 1480 2000 4000 6000 3200 3600 2000
(By others)
Gallery
Vent Fan
Gallery
Gallery
Gallery
(By
(By
(By
(By
(By
Overhead (OH)
Y
CB
8 550 800 1400×1030 1460×1185 1800 3700 5600 1660 2000 4000 6000 3400
B
4050 2250
CA
1400×1100 1460×1255 1800 3700 5600 1730 2000 4000 6000 3500
MY
11 750 800 1400×1350 1460×1505 1800 3700 5600 2000 2000 4000 6000 3700 4550 2800
Travel (TR)
Access Door(By others) 60
Min. 900(W)×2000(H) 1600×1400 1660×1555 2050 4200 6350 2050 2300 4400 6800 3800
1600×1500 1660×1655 2050 4200 6350 2150 2300 4400 6800 3850
15 1000 900 5450 4300
1600×1550 1660×1705 2050 4200 6350 2200 2300 4400 6800 3900
90
2100
40℃ with ventilating fan and /or air conditioner(if necessary)
and humidity below 90%. 17 1150 6600 5100
1100 2000×1350 2100×1520 2550 5200 7850 2130 2800 5250 8300 3800
Pit Depth (PP)
1800×1700 1900×1870 2350 4800 7250 2480 2600 4900 7500 4200
105 1000
1800×1730 1900×1900 2350 4800 7250 2510 2600 4900 7500 4300
20 1350 7800 6000
Ladder Waterproof Finish
(By others) (By others) 2000×1500 2100×1670 2550 5200 7850 2280 2800 5250 8300 4000
Receptacle 1100
(By others) 2000×1550 2100×1720 2550 5200 7850 2330 2800 5250 8300 4100
120
2000×1750 2100×1920 2550 5200 7850 2530 2900 5400 8300 4300
MX2 2000×1800 2100×1970 2550 5200 7850 2580 2900 5400 8300 4400
X2 MX3 24 1600 1100 8500 6800
X3 2150×1600 2250×1770 2700 5500 8300 2380 3000 5650 8700 4200
X1
X2
A 2150×1670 2250×1840 2700 5500 8300 2450 3000 5650 8700 4300
X1
R1 R1
Min. 100
A
R1 R1 R1
others)
others)
others)
others)
Fan(Byothers)
Gallery window(By others)
Notes : 1. White colored dimensions shall be applied for Malaysia & Singapore market.
Gallery window(By others)
2. Above hoistway dimensions are based on 15-storied buildings. For application to over 16-storied buildings,
Fan(By
Fan(By
Fan(By
VentFan(By
Beam
(By others) the hoistway dimensions shall be at least 5% larger considering the sloping of the hoistways.
3. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
Vent
Vent
Vent
B Vent
4. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
CB
CB
Y
B
(Unit : mm)
MY
OP OP OP
MY
Gallery window(By others)
OP OP R2 R2 R2
Vent Fan(By others)
90
Jamb Width
50
150
700
Thickness
Entrance Height (EH) : 2100
Wall
Steel
Steel
Steel
SteelBar
Steel Bar
Bar for
for
Barfor
Bar for
for
100
Concrete Opening : 2200
Wall Finish
Fixing
FixingJamb
Fixing Jamb
Jamb
Thickness
Fixing
Fixing
Fixing Jamb
Jamb
Jamb
HB With HPI 10 10
����� 9×6
9×6 (By others)
EA
EA
9×6 EAEA
(Byothers)
others)
500
9×6EAEA(By
9×6
EA
EA
EAEA
EA
(By
(By others)
others)
700 (150)
In case of Boxless Type 70 Clear Opening (OP) 70 HB With HPI
Clear
Clear
Clear
Clear
Clear
Buttons and Fire man‘s witch
1000
Opening (OP)
Opening(OP)
(OP) Concrete
10 Opening
Opening
Opening (OP)
(OP)
JP050 Type
Opening
OP+140
Finished Floor Level Wiring Inlet :� 50
(By others) (By others)
Jamb Width
90
JP050 Type (Basic)
700
Jamb Width
Thickness
Wall
Wall Finish
200
400
Thickness
700
Indicator
30
1700
Steel
Steel
Steel Bar
Bar for
for 30 (180)
SteelBar
Steel Barfor
Bar for
for 80
Fixing
FixingJamb
Fixing
Fixing Jamb
Jamb
Jamb
250
Fixing Jamb
Emergency Call ����� 9×6
9×6 EA
(By others) Hall
1050
9×6
9×6
EA
EAEA EA
(Byothers)
9×6EAEAEAEAEAEA(By
(By
(By others)
others)
others) 150 Clear Opening (OP) 150
50
150 Button
700
Switch
700
(For emergency call,
only rescus floor is Steel
Steel
Steel
SteelBar
Steel Bar
Bar for
for
Barfor
Bar for
for
Entrance Height (EH) : 2100
Fixing
Fixing Jamb
Jamb
Concrete Opening : 2200
applied)
Fixing
FixingJamb
Fixing Jamb
Jamb JP100, JP200 Type
Jamb Height (JH)
����� 9×6
9×6 (By others)
EA
EA
9×6
9×6
EAEA
EAEA (Byothers)
9×6EAEAEAEA(By
EA
(By
(By others)
others)
others) 90
HB
700
(By others)
JP050 Type
Wall and Floor Finishing
(By other Contractors)
Clear
Clear
Clear
Clear
Clear
Clear
1000
30 Opening
Opening
Opening
Opening (OP)
Opening(OP)
(OP)
(OP)
(OP) Concrete
700
Opening
50
OP+300
50
Finished Floor Level
50
(By others)
Ceiling Line
Upper
100
JP100 Type (Optional) frame
10 10
(By others)
Switch Switch
(For emergency (For emergency
Jamb Height (JH)
300
HB HB
700
1650
50
50
50
1000
Clear
Clear
Clear
Clear
Clear Clear
Clear
Clear
Clear
Clear Concrete
Opening
Opening (OP)
Opening(OP)
(OP) Opening (OP)
Opening(OP)
Opening (OP) Opening 90 90 90
30 Opening
Opening (OP)
(OP) 30 Opening
Opening (OP)
(OP)
700
OP+300
The first call determines the direction of the elevator. All calls opposing the respective 14) Multi-beam door Multi-beam from the top to the bottom of the door senses any obstruction caught in the door.
1) Selective collective � ★
direction are serviced after carrying out by the calls of the respective direction. protection It makes the door reopen, or keep open/close before the door is touched such obstruction.
2) Duplex selective
2 units of elevator provide the effective service for the common hall calls ★ When a fire breaks out, all cars activated by the switch or fire detector are immediately
collective 15) Fire emergency service ★
called to a specified rescue floor for the passenger’s safety.
When a car is 80% loaded, it will automatically bypass all hall calls as the bypass load
3) Automatic bypass weighing device is activated.
�
Evaluates the number of people on the car and compares that value to the number of the car
calls registered. If the number of car calls exceeds the number of people in the car by the load
16) Anti-nuisance ★
4) Chime bell It provides an audible indication in the car that an elevator is about to arrive. � sensor, the car call exceeding the number of passengers will be cancelled after service
nearest all only.
Digital(Segment) type �
5) Signal fixtures Dot matrix type(moving direction) ★ A voice synthesizer with microprocessor makes announcements to inform passengers of
Hall lantern ★ 17) Voice synthesizer ★
various conditions, including landing floor and operation direction, etc.
Contact with a passenger or inanimate object causes the doors to stop and
6) Single-side safety During normal power failure, elevator service continues with building’s
reopen automatically. � 18) Emergency power ★
edge of door The elevator doesn’t start if the door is completely not closed.
emergency power source.
7) Ventilation fan Car ventilation is smooth with ventilation fan built-in the ceiling. � When the fireman’s switch located at the main floor lobby and operating panel on the car is
19) Fireman’s emergency
activated during a fire or other emergency, a designated car can be called back to a specified ★
service floor for fire fighting service.
8) Emergeny car lighting In case of the power failure, it lights automatically in the car. �
When the door is opened, the switch installed at the door operator is activated and keeps In the event of the power failure, the elevator power automatically switches to a rechargeable
10) Door interlock switch the car from moving. During the operation of car, it locks the door completely so as not to � 21) Emergency landing battery built-in controller that moves the car to the nearest floor and allows passengers to
safely exit. ★
open the door from out side. device(ELD)
This can be used when no emergency power source in the building is available.
11) Interphone & emergency In case of emergency, the passenger can communicate with the personnel in control room It is activated when the attendant turns on the ATT switch in the car operating
� 22) Attendant service ★
call button or in prevention center of disasters by pushing the emergency call button. panel to“ON”position.
When the seismic sensor detects and earthquake that exceeds a predetermined level,
To protect the overload of elevator, this device sounds a buzzer and the elevator remains 23) Earthquake operation all cars promptly proceed to land at the nearest floor and park with the doors open to allow ★
12) Overload features stopped at that floor when the number of passengers exceeds the rated capacity. When the � passengers to exit out safely.
excess number of passengers get out of the car, the buzzer stops and the elevator door closes.
The car can be parked at a specified floor, during the nights or holidays with operate
24) Parking parking switch on hall button.
★
During the operation if the car stops between floors, and safety device doesn’t work, the car
13) Safety drive automatically moves to the nearest floor with the low speed. Then, it opens the door to allow �
the passengers to exit off. Notes : 1. � : Standard, ★: Optional
2. Consult Hyundai if you need the specific features except the above items.
iron ladder extending 1060mm minimum above sill of access door. (Rule 106.1d) 9. Elevator fireman’s and other emergency services’wiring and interconnections 60 11(6.2) 50(30) 50(40) 10(8) 18(15) 14(5.5) 14(8) 5.5(5.5) 8(8)
9. Entrance walls and finished floor are not to be constructed until after door to automatic sprinkler systems or heat and smoke sensing devices furnished by 15 90 15(9.2) 50(30) 75(50) 11(10) 19(17) 14(5.5) 22(14) 5.5(5.5) 8(8)
frames and sills are in place. others and installed to terminal points on the elevator controllers.
(1000) 105 15(10.8) 50(40) 75(50) 12(11) 20(18) 14(5.5) 22(14) 5.5(5.5) 8(8)
Door frames are to be anchored to walls and properly grouted in place to main- 10. When emergency power operation of elevators is required, the electrical con-
120 18.5(12.3) 75(40) 100(75) 14(13) 24(22) 22(14) 30(22) 8(5.5) 8(8)
tain legal fire rating. tractor should coordinate with Hyundai Elevator Company or local distributor
10. Sill supports 64mm minimum floor recesses full hoistway width for entrance for operation requirements. 60 11(7.1) 50(30) 75(40) 12(9) 22(17) 14(5.5) 22(14) 5.5(5.5) 8(8)
sills, with grouting after sills are set in place. 11. Elevator fireman’s and other emergency service requirements may differ from
17 90 15(10.6) 75(40) 100(75) 13(12) 22(21) 14(5.5) 22(14) 5.5(5.5) 8(8)
11. For application as indoor observation elevator, a minimum 3.6m high glass each country. Consult Hyundai Elevator Company or local distributor for other
(1150) 105 18.5(12.4) 50(40) 100(75) 14(13) 24(22) 22(8.0) 30(22) 8(5.5) 8(8)
enclosure above bottom landing is recommended for safety. local requirements.
12. When provisions for earthquake protection are required, consult Hyundai 120 22(14.1) 75(40) 100(75) 15(14) 26(23) 22 30(22) 8(5.5) 8(8)
For application as outdoor observation elevator, full height glass enclosure is
required. Elevator Company for special requirements. 60 15 50 75 14 23 14 22 5.5 8
20 90 18.5 75 100 15 25 22 30 8 8
Machine Room
(1350) 105 22 75 100 16 27 22 30 8 8
12. Enclosed and protected machine room. (Rule 101.1)
13. Access to the machine room and machinery space as required by the governing Heat Emission Of 120 30 100 150 23 39 30 38 14 14