OWNER’S MANUAL

Installation, Operation
& Maintenance

375 Marcus Boulevard • Hauppauge, NY 11788 • USA


631.273.0500 • Fax: 631.273.0771
e-mail: info@atlanticuv.com • Extensive Product Information Available at:

www.ultraviolet.com
UPDATED 04/28/09
User Assistance
Atlantic Ultraviolet Corporation makes every effort to ensure that the Megatron™ Water Disinfection
Systems are products of superior quality and workmanship. This manual describes the installation,
operation and maintenance of the Megatron ™ Water Disinfection System.

Please read and become familiar with the contents of this manual before installing or using this unit. If
after reading the manual you still have questions, or concerns, regarding the installation or use of this
unit, contact our offices, weekdays between 8:30 am and 5:00 pm Eastern time, at:

Atlantic Ultraviolet Corporation


375 Marcus Boulevard
Hauppauge, New York, 11788

Tel: 631.273.0500
Fax: 631.273.0771

E-mail: info@ultraviolet.com
Website: www.ultraviolet.com

Please fill out and return the Owner Registration card immediately. If the card is missing from this manual,
please contact any of our application specialists to obtain one.

Atlantic Ultraviolet Corporation takes all possible precautions when packaging equipment to prevent
damage. Carefully inspect and report all damage. Do not install damaged equipment.
Follow all instructions on any labels or tags. Carefully inspect all packing materials before discarding to
prevent the loss of accessories, mounting hardware, spare parts or instructions.

For your convenience, record the following information below. The model and serial number can be found
on a label located on the rear of the electrical enclosure. Keep this manual, along with proof of purchase,
handy when contacting our offices.

Purchased From: Date:

Model No: Serial No:


 

375 Marcus Boulevard


Hauppauge, New York 11788
 
Tel: 631.273.0500
 
Fax: 631.273.0771
631.273.0780
THE STANDARD OF EXCELLENCE IN ULTRAVIOLET  
  www.ultraviolet.com
Manufacturers / Engineers / Sales / Services e-mail: info@ultraviolet.com
 
 
OWNER’S MANUAL – MEGATRON™ WITH DIGITAL UV MONITOR N0 WIPER
 
1) GENERAL SYSTEM INFORMATION
 
2) INSPECTION OF SYSTEM AFTER DELIVERY
 
3) LAMP INSTALLATION
 
4) FRONT PANEL FEATURES
 
5) INSIDE FRONT PANEL FEATURES
 
6) DIMENSIONAL DATA
 
7) REMOTE OUTPUT CONNECTIONS
 
8) ADUSTMENT OF ULTRAVIOLET MONITOR
 
9) NOMENCLATURE & PARTS LIST DRAWING
 
10) LAMP REPLACEMENT
 
11) QUARTZ SLEEVE CLEANING OR REPLACEMENT
 
12) STATIC GLAND NUT WRENCH INSTRUCTIONS
 
13) RECOMMENDED SPARE PARTS
 
14) FRONT PANEL ASSEMBLY
 
15) FRONT PANEL WIRING DIAGRAM
 
16) LAMP OUT INDICATORS
 
17) REMOTE PROBE
 
18) ELECTRICAL ASSEMBLY
 
19) BALLAST ASSEMBLY – LH
 
20) BALLAST WIRING DIAGRAM – LH
 
21) BALLAST ASSEMBLY – RH (ON MODELS M90, M150, & M250 ONLY)
 
22) BALLAST WIRING DIAGRAM – RH (ON MODELS M90, M150, & M250 ONLY)
 
23) BLOWER ASSEMBLY
 
24) POWER DISTRIBUTION ASSEMBLY
 
25) POWER DISTRIBUTION WIRING
 
26) COMPLETE CHAMBER ASSEMBLY
 
27) SYSTEM LOG
 
28) WARRANTY
 
 
 
 
GERMICIDAL LAMPS & FIXTURES / AIR PURIFICATION EQUIPMENT / WATER PURIFICATION EQUIPMENT / LIQUID DISINFECTION EQUIPMENT
OZONE GENERATORS / WASTE WATER DISINFECTION SYSTEMS / PHOTOTHERAPY EQUIPMENT / BLACK LIGHT LAMPS & EQUIPMENT
Safety:

Precautions must be taken to avoid exposure to ultraviolet radiation produced by this unit.

Exposure of skin and eyes should be kept to a minimum. A face shield should be worn when working on, or
around this unit to protect eyes and facial skin from exposure. Long sleeve shirts should be worn to protect all
exposed skin including the neck area and arms. Gloves can be worn to protect the hands.

In addition this unit's wiper system should never be utilized with both the inlet and outlet closed off from flow.
Failure to follow this recommendation may result in seal leakage in the unit.

General Unit Information:

The Megatron™ is intended for indoor use. Although it is capable of being installed outdoors, units should
be protected from the elements, direct sunlight, and from temperatures below freezing. Shut off valves
should be installed on both the inlet and outlet sides of the unit. The shut off valves allow the unit to be
isolated from the water supply, which may be required when performing unit inspections, or maintenance.
Units should be located in a dry, well-lit area, which provides enough room to perform routine maintenance.
This includes a minimum height of 14 inches, from the floor, with a preferred height of 30 inches, and
approximately 71 inches clearance around at least one end of the unit, to allow for cleaning and/or
changing of the lamps and quartz sleeves.

System Start-Up:

When this unit receives its first flow of water it is advisable to let water enter the unit at a low flow rate and be
allowed to fill with water until the unit is pressurized. As the unit fills with water it should be check for leaks.
Once the unit reaches it's desired pressure without leaking the flow rate can be gradually increased followed by
the unit power up.

Wiper Operation:

The simplest way to insure that your quartz sleeves remain clean is to set your wiping cycle to wipe once a
week. This method will normally work well on most applications. If perhaps your monitor continues to show a
significant drop in UV output or an increase in bacteria is shown in water tests you can increase the wiping
cycle to twice a week. This procedure can be repeated until the cycle time happens often enough that your
monitor only indicates a small drop in intensity or acceptable bacteria count is shown in water tests. (For
automatic wiper systems, see Programming Wiper Controller)

Another method is based upon your monitor intensity reading. This method suggests that your cycle time for
wiping the quartz sleeves be set to roughly half the time it takes for a significant drop in the UV meter. For
example: if after a period of 96 hours the ultraviolet meter drops into the red zone, your cycle time should be
set to 48 hours. This method can also be checked with a water test to determine if the bacteria exiting the unit
are at an acceptable level.

Monitor Adjustments:

All adjustments should be made to the ultraviolet monitor system when the unit first begins operating. (See
Adjustments of Ultraviolet Monitor)
Cleaning:

The quartz sleeves must be periodically cleaned to remove any deposits or discoloration, which may hinder the
ability of the ultraviolet radiation to pass through the sleeves into the liquid.

Since water quality varies greatly from site to site, determining when the quartz sleeves require cleaning can be
difficult. One method for determining how often to clean quartz sleeves would be to visually inspect the quartz
sleeves after one week of operation, followed by interval inspections of one week until fouling begins to occur.
This period of time can help determine the cleaning cycle. For example, if fouling begins to occur after 4 weeks,
cleaning should be every 3 weeks, or 3/4 of the time that it takes for fouling to begin to occur.

The ultraviolet monitor can help to indicate when the quartz sleeves require cleaning. Over time the intensity
level displayed by the monitor will decline moving from green “UV Normal” to red “UV Low”. This reduction
could indicate fouling or deposits on the quartz sleeves and/or on the ultraviolet sensor probe and that cleaning
is required.

In addition a rise in the total bacteria count in the effluent may also indicate that the quartz sleeves require
cleaning.

Cleaning of the quartz sleeves can be accomplished by using the manual or automatic wiper system. If the
wiper is not improving your fouling condition the quartz sleeves can be removed from the unit one at a time and
rinsed with a mild detergent or citric acid. Sleeves can be hand wiped or dipped into a cleaning tank and then
rinsed with water. Stubborn stains can be removed using a dilute hydrochloric acid.

Lamp Replacement:

Lamp replacement is recommended once every year of operation. It is recommended that lamp remain on at
all times since the cycling of the lamps on and off may reduce the lamp life. Lamp Out Indicators located on the
unit’s front panel illuminate showing lamp is on. A dimly lit or out indicator alerts personnel that lamp requires
replacement.

Quartz Sleeve Replacement:

Quartz sleeves are very fragile and easily broken. It is recommended that spare sleeves be kept on hand in
case replacement is required. Normally sleeves do not require periodical replacement unless broken or if
surface stains appear that cannot be removed.
ITEM QTY PART NUMBER DESCRIPTION
1 1 251421A TOOL: STATIC GLAND NUT WRENCH - MEGATRONS
2 1 251492D STATIC GLAND NUT
3 38 251235A TEFLON WASHER: .882 ID X 1.114 OD X .050 THICK
4 38 001238A O-RING: .875 ID X 1.125 OD X .125 C/S BUNA-N
2
1
STATIC GLAND NUT UNDERCUTS
(2-PLACES)
WRENCH TANGS
(2-PLACES)
DETAIL A
4
NOTES:
3
1) USE STATIC GLAND NUT WRENCH TO INSTALL AND REMOVE STATIC GLAND NUTS
ON ALL MEGATRON UNITS. 2
2) LINE UP WRENCH TANGS TO STATIC GLAND UNDERCUTS AND TWIST HANDLE,
CLOCKWISE TO TIGHTEN, COUNTER-CLOCKWISE TO UN-TIGHTEN.
3) STATIC GLAND NUTS SHOULD BE TIGHTEND SNUG TO PROVIDE A SEAL BETWEEN
THE O-RING AND UNIT.
1
A
(***UNIT SHOULD ABOVE IS A MEGATRON MODEL M250)
DRAWN
REMOVE ALL BURRS AND SHARP EDGES Mark Wyckoff 1/10/2013
A RELEASED 1/10/2013 MW
CHECKED
LTR DESCRIPTION DATE APPROVED
TOLERANCES:
UNLESS OTHERWISE NOTED:
REVISIONS MFG
DWG NO. TITLE OVER
UP TO 6" OVER 24"
INSTRUCTIONS ON STATIC GLAND NUT WRENCH 6" TO 24"
APPROVED
251419A (PN# 251421A) FOR MEGATRON UNITS 2 PL “.02" “.03" “.06" 1/10/2013
MW
375 MARCUS BOULEVARD * HAUPPAUGE, NY 11788
THIS DRAWING CONTAINS DESIGNS AND OTHER INFORMATION WHICH ARE THE PROPERTY OF ATLANTIC ULTRAVIOLET CORPORATION. 3 PL “.010" “.016" “.031"
EXCEPT FOR RIGHTS EXPRESSLY GRANTED BY CONTRACT TO THE UNITED STATES GOVERNMENT, THIS DRAWING MAY NOT, IN WHOLE
PHONE: 631.273.0500 * FAX: 631.273.0771
OR IN PART, BE DUPLICATED OR DISCLOSED OR USED FOR MANUFACTURE OF THE PART DISCLOSED HEREIN, WITHOUT THE PRIOR
FRAC “1/32" “1/16" “1/8" INFO@ULTRAVIOLET.COM * WWW.ULTRAVIOLET.COM
WRITTEN PERMISSION OF ATLANTIC ULTRAVIOLET CORPORATION. “1/2` 251419A.idw
ANGLE
Copyright 2007 Atlantic Ultraviolet Corporation SHEET 1 OF 1
RECOMMENDED SPARE PARTS LIST
Megatron M50
Description Part No.
Germicidal Ultraviolet Lamp 05-1313A-R
Quartz Sleeve 15-1000A
Head Gasket 25-1475C
O-Ring (Rubber) 00-1238A
O-Ring (Teflon) 25-1235A
Ballast - (for 120 Volt Units) 10-0091
Ballast - (for 220 Volt Units) 10-0127

Megatron M90
Description Part No.
Germicidal Ultraviolet Lamp 05-1313A-R
Quartz Sleeve 15-1000A
Head Gasket 25-0328D
O-Ring (Rubber) 00-1238A
O-Ring (Teflon) 25-1235A
Ballast - (for 120 Volt Units) 10-0091
Ballast - (for 220 Volt Units) 10-0127

Megatron M150
Description Part No.
Germicidal Ultraviolet Lamp 05-1313A-R
Quartz Sleeve 15-1000A
Head Gasket 25-0354C
O-Ring (Rubber) 00-1238A
O-Ring (Teflon) 25-1235A
Ballast - (for 120 Volt Units) 10-0091
Ballast - (for 220 Volt Units) 10-0127

Megatron M250
Description Part No.
Germicidal Ultraviolet Lamp 05-1313A-R
Quartz Sleeve 15-1000A
Head Gasket 25-1460D
O-Ring (Rubber) 00-1238A
O-Ring (Teflon) 25-1235A
Ballast - (for 120 Volt Units) 10-0091
Ballast - (for 220 Volt Units) 10-0127

375 Marcus Boulevard • Hauppauge, NY 11788 • USA


631.273.0500 • Fax: 631.273.0771
e-mail: info@ultraviolet.com
Document No. 98-1002 • Revised October 2014 Extensive Product Information Available at: ultraviolet.com
1 2 3 4 5

8 9 10 11
A
SECTION A-A

ITEM QTY PART NUMBER DESCRIPTION


1 1 301061A SENSOR PROBE CAP: 5mm
2 1 302014 LOWER PROBE BODY - (302013A) 316 SST
3 1 000284A O-RING: .943 OD X .737 ID X .103 C/S BUNA-N
4 1 000325A O-RING: .755 OD X .549 ID X .103 C/S BUNA-N
5 1 308363A SENSOR BODY ASSEMBLY w/5 POLE CONNECTOR
6 1 308362A REMOTE PROBE PWB ASSEMBLY w/HOLDER
7 1 150100A QUARTZ ROD: .196 DIA. X 2-3/16" LONG
8 1 302039A WASHER: BACKUP .040 THICK SST
NOTES: 9 1 000280A O-RING: .176 ID X 1/16" C/S BUNA-N
10 1 000281A O-RING: .424 ID X .630 OD X .103 C/S BUNA-N
1) PLACE DESICCANT (ITEM 12) ON BACK SIDE OF PCB ASSEMBLY (ITEM 6). 11 1 502021 WASHER: WAVY 440 ID X .618 OD X .008 THK.
12 1 000201 DESICCANT: SILICA GET (NOT SHOWN)

DRAWN
REMOVE ALL BURRS AND SHARP EDGES Mark Wyckoff 8/17/2017
A RELEASED 8/18/2017 MW
CHECKED
LTR DESCRIPTION DATE APPROVED
TOLERANCES:
UNLESS OTHERWISE NOTED:
REVISIONS MFG
DWG NO. TITLE OVER
UP TO 6" OVER 24"
REMOTE SENSOR PROBE ASSEMBLY WATER 6" TO 24"
APPROVED
308235B 2 PL .02" .03" .06" 8/18/2017
RESIST. 5 POLE MALE CONNECTOR & PCB CONN MW
375 MARCUS BOULEVARD * HAUPPAUGE, NY 11788
THIS DRAWING CONTAINS DESIGNS AND OTHER INFORMATION WHICH ARE THE PROPERTY OF ATLANTIC ULTRAVIOLET CORPORATION. 3 PL .010" .016" .031"
EXCEPT FOR RIGHTS EXPRESSLY GRANTED BY CONTRACT TO THE UNITED STATES GOVERNMENT, THIS DRAWING MAY NOT, IN WHOLE
PHONE: 631.273.0500 * FAX: 631.273.0771
OR IN PART, BE DUPLICATED OR DISCLOSED OR USED FOR MANUFACTURE OF THE PART DISCLOSED HEREIN, WITHOUT THE PRIOR FRAC 1/32" 1/16" 1/8" INFO@ULTRAVIOLET.COM * WWW.ULTRAVIOLET.COM
WRITTEN PERMISSION OF ATLANTIC ULTRAVIOLET CORPORATION. 1/2 308235B.idw
ANGLE
Copyright 2007 Atlantic Ultraviolet Corporation SHEET 1 OF 1
1
A
6 7 15 18

8 16 19

17 21
9
2 20 (60" LONG)
10
RIGHT HAND
BLOWER
11
CONTROL
23 (SEE NOTE 3) PANEL
SEE NOTE 2
LEFT HAND
3 BALLAST TRAY

RIGHT HAND
BALLAST TRAY
B 24 (SEE NOTE 4)
LEFT HAND
BLOWER
4
12

13 20 (56" LONG)
B 14 21 PN# 250784BX
5 20 (40" LONG)

21

25
A
SECTION A-A 22

ITEM B1 QTY. B2 QTY. B4 QTY. DESCRIPTION PART NUMBER


14
1 1 1 1 PANEL, POWER DISTRIBUTION PANEL 250516C1
2 1 1 1 TERMINAL BLOCK: 4 SETS WITH 2 JUMPERS 350804A 13
3 1 1 1 TERMINAL BLOCK: 3 POSITION HIGH VOLTAGE 351036
4 1 1 1 TERMINAL: RING 22-16 GA. INSULATED RED 350137 4
5 1 1 1 STRAIN RELIEF .20-.35 DIA. 1/2" NPT 350052
6 4 4 4 TERMINAL DISCONNECT 1/4" RED INSULATION 351578-R 12
7 1 1 1 CIRCUIT BREAKER: 277v 50/60Hz 30A 350267
8 2 2 2 NUT: #4-40 FINISH HEX NUT 18-8 SST 501186
SECTION B-B
9 2 2 2 SCREW: #4-40 X 1/2" PAN HD. PHIL 18-8 SST 500098
10 2 2 2 WASHER: #4 FLAT 1/8" ID X 5/16" OD X .03 THK. 18-8 SST. 501187
11 2 2 2 WASHER: #4 LOCKWASHER MDE 18-8 SST 500017
12 2 2 2 WASHER: #8 FLATWASHER 3/16" ID X 3/8" OD X .04" THICK 501045
13 3 3 3 WASHER: #8 EXT. TOOTH LOCK 410 SST 500089 MODEL PART NUMBERS QTY. DESIGNATION
14 3 3 3 NUT: #8-32 FINISH HEX NUT 18-8 SST 501180 M50 250784B1 B1
15 4 4 4 SCREW: #6-32 X 1/4" PH SLOT MACH 18-8 501179 M90 250784B2 B2
16 4 4 4 WASHER: #6 EXT. TOOTH LOCK 500088 M150 250784B2 B2
17 4 4 4 WASHER: #6 FLAT "5/32 ID X 5/16" OD X .03 THICK 18-8 SST 501402 NOTES: M250 250784B4 B4
18 1 1 2 POWER CABLE: MEGATRON BLOWER 250584A2
19 1 1 2 STRAIN RELIEF: BUSH STR THRU BLK .255-.290 CABLE DIA 351101
1) SEE DRAWINGS 250770B1 FOR MEGATRON M50, 250770B2 FOR MEGATRON M90 &
20 2 3 3 LEAD CORD, RIGHT ANGLE 18/3 SJT 351714
21 2 3 3 STRAIN RELIEF .325-.360 CABLE 351323
M150, & 250770B4 FOR MEGATRON M250 WIRING DETAILS.
22 120" 120" 120" CABLE, 3 COND. 14 AWG TYPE SJOW-A 351499 2) LABEL ALL WIRE OUTPUTS AS SHOWN ABOVE USING BRADY LABEL (1/2" X 1-1/2") PN# 990157.
23 1 1 - PLUG, CONDUIT, 1/2" DIAMETER 000027 3) USE ITEM 23, (PN#000027) ON MEGATRON MODELS M50, M90, & M150.
24 1 - - PLUG, CONDUIT, 5/8" DIAMETER 000123 4) USE ITEM 24, (PN# 000123) ONLY ON MEGATRON MODEL M50.
25 1 1 1 STRAIN RELIEF LOCKING NUT: FOR USE WITH 350052 350433 5) CUT ITEM 20, (PN# 351714) TO LENGTHS SHOWN ABOVE.
DRAWN
REMOVE ALL BURRS AND SHARP EDGES Mark Wyckoff 1/29/2013
A RELEASED 5/26/2015 MW
CHECKED
LTR DESCRIPTION DATE APPROVED
TOLERANCES:
UNLESS OTHERWISE NOTED:
REVISIONS MFG
DWG NO. TITLE OVER
UP TO 6" OVER 24"
POWER DISTRIBUTION PANEL MEGATRON MODELS 6" TO 24"
APPROVED
250784B1 2 PL .02" .03" .06" 5/26/2015
M50, M90, M150 & M250 MW
THIS DRAWING CONTAINS DESIGNS AND OTHER INFORMATION WHICH ARE THE PROPERTY OF ATLANTIC 375 MARCUS BOULEVARD * HAUPPAUGE, NY 11788
3 PL .010" .016" .031"
ULTRAVIOLET CORPORATION. EXCEPT FOR RIGHTS EXPRESSLY GRANTED BY CONTRACT TO THE UNITED PHONE: 631.273.0500 * FAX: 631.273.0771
STATES GOVERNMENT, THIS DRAWING MAY NOT, IN WHOLE OR IN PART, BE DUPLICATED OR DISCLOSED OR FRAC 1/32" 1/16" 1/8" INFO@ULTRAVIOLET.COM * WWW.ULTRAVIOLET.COM
USED FOR MANUFACTURE OF THE PART DISCLOSED HEREIN, WITHOUT THE PRIOR WRITTEN PERMISSION OF
ANGLE 1/2 250784B1.idw
ATLANTIC ULTRAVIOLET CORPORATION.
Copyright 2007 Atlantic Ultraviolet Corporation SHEET 1 OF 1
Warranty
We warrant that this product will be free from defects in material and workmanship for a period of one
year from the date of shipment thereof or the product’s total rated life, whichever first occurs. Within the
warranty period we shall repair or replace such products, which are returned to us with shipping charges
prepaid, and which are determined by us to be defective. This warranty will not apply to any product,
which has been subjected to misuse, negligence, or accident; or misapplied; or modified; or repaired by
unauthorized persons; or improperly installed.

The Buyer shall inspect the product promptly after receipt and shall notify us at our main office in writing
of claims, including claims of breach of warranty, within thirty days after the Buyer discovers or should
have discovered the facts upon which the claim is based. Failure of the Buyer to give written notice of a
claim within the time period shall be deemed to be a waiver of such claim.

The provisions of the above warranty are our sole obligation and exclude all other remedies or warranties,
expressed or implied, including warranties of merchantability and fitness for a particular purpose, whether
or not purposes or specifications are described herein. We further disclaim any responsibility whatsoever
to the customer, or to any person, for injury to person, damage to, or loss of property or value caused by
any product which has been subjected to misuse, negligence, accident; or modified or repaired by
unauthorized persons; or improperly installed.

Under no circumstances shall the Company be liable for any incidental, consequential or special
damages, losses or expenses arising from the contract for this product, or in connection with the use of,
or inability to use, our product for any purpose whatsoever.

Patent Notice
No attempt has been made to determine the patent status of applications illustrated or described in this
publication. Inclusion in this publication of any design or method of use, which may be patented, is not to
be construed as promoting or sanctioning unauthorized use.
375 Marcus Boulevard
Hauppauge, NY 11788
Phone: 631.273.0500
Fax: 631.273.0771
‘THE STANDARD OF EXCELLENCE IN ULTRAVIOLET’ 631.273.0780
Manufacturers / Engineers / Sales / Service

Megatron Production Sheet:


Model: M250: 220v/50Hz Digital Monitor 4-20ma, 6” 150# Flg / 316 SST, NO-Wiper
Part No: 24-2527A1
Sold To: Republica de Cuba 1034
Date: 10/13/17
Order No: 327972
Serial No: 149300 / Probe 100232

Item No. Description Part No. Drawing Date:


1 Complete Assembly 24-2527A1 10/17/17

2 Complete Electrical Enclosure 25-0637B6 01/31/17

3 Electrical Enclosure 25-0543A2 04/07/14

4 Control Panel Assembly 25-1078B 06/26/17

5 Wiring Diagram – Control Panel 25-0889B 01/18/17

6 Remote Sensor Probe Assy. 30-8235B 08/18/17

7 Ballast Tray Assembly: LH 25-1338A2 07/11/09

8 Ballast Tray Assembly: RH 25-1340A2 07/11/09

9 Power Distribution Panel 25-0784B1 05/26/17

10 Blower Assembly: LH 25-0577A3 09/20/10

11 Blower Assembly: RH 25-0577A4 10/26/10

12 Complete Chamber Assembly 25-1620A 10/17/17

GERMICIDAL LAMPS & FIXTURES / AIR PURIFICATION EQUIPMENT / WATER PURIFICATION EQUIPMENT / LIQUID DISINFECTION
OZONE GERATORS / WASTE WATER DISINFECTION SYSTEMS / PHOTOTHERAPY EQUIPMENT / BLACK LIGHT LAMPS & EQUIPMENT
 
"T
HI
S
PA
GE
IN
TE
NT
IO
NA
LL
Y
LE
FT
BL
AN
K"
OWNER’S MANUAL
Installation, Operation
& Maintenance

375 Marcus Boulevard • Hauppauge, NY 11788 • USA


631.273.0500 • Fax: 631.273.0771
e-mail: info@atlanticuv.com • Extensive Product Information Available at:

www.ultraviolet.com

You might also like