Manual Transmitter M200 Easy e 52121501 Sept09
Manual Transmitter M200 Easy e 52121501 Sept09
Manual Transmitter M200 Easy e 52121501 Sept09
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 3
Operation Manual
Transmitter M200 easy
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 4
Content
1 Introduction_ ___________________________________________________________________________________________ 7
2 Safety instructions_______________________________________________________________________________________ 7
2.1 Definition of equipment and documentation symbols and designations_________________________________________ 7
2.2 Correct disposal of the unit _ _________________________________________________________________________ 8
3 Unit overview___________________________________________________________________________________________ 9
3.1 Overview 1/4DIN___________________________________________________________________________________ 9
3.2 Overview 1/2DIN___________________________________________________________________________________ 9
3.3 Control/Navigation Keys____________________________________________________________________________ 10
3.3.1 Menu Structure____________________________________________________________________________ 10
3.3.2 Navigation keys___________________________________________________________________________ 10
3.3.2.1 Navigating the menu tree__________________________________________________________ 10
3.3.2.2 Escape________________________________________________________________________ 11
3.3.2.3 Enter__________________________________________________________________________ 11
3.3.2.4 Menu__________________________________________________________________________ 11
3.3.2.5 Calibration mode_ _______________________________________________________________ 11
3.3.2.6 Info mode______________________________________________________________________ 11
3.3.3 Navigation of data entry fields________________________________________________________________ 11
3.3.4 Entry of data values, selection of data entry options_______________________________________________ 11
3.3.5 Navigation with in Display_________________________________________________________________ 12
3.3.6 Save changes dialog______________________________________________________________________ 12
3.3.7 Security Passwords________________________________________________________________________ 12
3.4 Display_________________________________________________________________________________________ 12
4 Installation instruction___________________________________________________________________________________ 13
4.1 Unpacking and inspection of equipment________________________________________________________________ 13
4.1.1 Panel cutout dimensional information 1/4DIN models____________________________________________ 13
4.1.2 Installation procedure 1/4DIN models_ _______________________________________________________ 14
4.1.3 Panel cutout dimensional information 1/2DIN models____________________________________________ 15
4.1.4 Installation procedure 1/2DIN models_ _______________________________________________________ 16
4.1.5 Assembly 1/2DIN version__________________________________________________________________ 16
4.1.6 1/2DIN version Dimension drawings_________________________________________________________ 17
4.1.7 1/2DIN version Pipe mounting______________________________________________________________ 17
4.1.8 1/4DIN version Dimension drawings_________________________________________________________ 18
4.2 Connection of power supply_________________________________________________________________________ 19
4.2.1 1/4DIN housing (panel mount)_______________________________________________________________ 19
4.2.2 1/2DIN housing (wall mount)________________________________________________________________ 20
4.3 Connector terminal definition_ _______________________________________________________________________ 21
4.3.1 TB1 and TB2 for 1/2DIN and 1/4DIN versions_ __________________________________________________ 21
4.3.2 TB3/TB4* pH, ORP, oxygen and 4-electrode conductivity sensor____________________________________ 21
4.3.3 TB3/TB4 2-electrode Conductivity sensor _____________________________________________________ 22
4.4 Assembling of sensor and cable______________________________________________________________________ 23
4.4.1 Connection of sensors for pH, ORP, oxygen and 4-electrode conductivity_______________________________ 23
4.4.2 AK9 Cable Assignment_ ____________________________________________________________________ 23
5 Placing transmitter in, or out, of service ____________________________________________________________________ 24
5.1 Placing transmitter in service________________________________________________________________________ 24
5.2 Placing transmitter out of service _____________________________________________________________________ 24
6 Quick Setup_ __________________________________________________________________________________________ 25
7 Sensor Calibration______________________________________________________________________________________ 26
7.1 Enter Calibration Mode_____________________________________________________________________________ 26
7.2 Conductivity/Resistivity Calibration _ __________________________________________________________________ 26
7.2.1 One-point Sensor Calibration ________________________________________________________________ 27
7.2.2 Two-point Sensor Calibration (4-electrode sensors only)_ __________________________________________ 27
7.2.3 Process calibration ________________________________________________________________________ 28
7.3 Oxygen Calibration________________________________________________________________________________ 29
7.3.1 One-Point Sensor Calibration_________________________________________________________________ 29
7.3.2 Process Calibration________________________________________________________________________ 29
7.4 pH Calibration____________________________________________________________________________________ 30
7.4.1 One point calibration _ _____________________________________________________________________ 30
7.4.1.1 Auto mode_ ____________________________________________________________________ 30
7.4.1.2 Manual mode___________________________________________________________________ 31
7.4.2 Two point calibration _ _____________________________________________________________________ 31
7.4.2.1 Auto mode_ ____________________________________________________________________ 31
7.4.2.2 Manual mode___________________________________________________________________ 32
7.4.3 Process calibration ________________________________________________________________________ 32
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 5
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 6
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 7
1 Introduction
Statement of Intended Use The M200 easy multiparameter transmitter is a single- or dual
channel online process instrument for measuring various properties of fluids. These include
Conductivity/Resistivity, Dissolved Oxygen, pH and ORP. It will interface with a variety of different
Mettler-Toledo sensors, which connect to the transmitter using cables of varied lengths.
A large four line backlit Liquid Crystal Display conveys measuring data and setup information.
The menu structure allows the operator to modify all operational parameters by using keys on
the front panel. A menu-lockout feature, with password protection, is available to prevent the
unauthorized use of the meter. The M200 easy multiparameter transmitter can be configured to
use its 2 (4 on dual channel version) analog and/or 2 relay outputs for process control.
The M200 easy multiparameter transmitter is equipped with a USB communication interface.
This interface provides real-time data output and complete instrument configuration capabilities
for central monitoring via Personal Computer (PC).
This manual applies for all available M200 easy transmitters as follows:
Mulitparameter dual channel version
Mulitparameter single channel version
The print screen images in this manual have a general explaining character and can differ from
the real display in your transmitter.
2 Safety instructions
This manual includes safety information with the following designations and formats.
On the transmitter or in this manual text indicates: Caution and/or other possible hazard
including risk of electric shock (refer to accompanying documents).
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 8
The following is a list of general safety instructions and warnings. Failure to adhere to these
instructions can result in damage to the equipment and/or personal injury to the operator.
The M200 easy transmitter should be installed and operated only by personnel familiar with
the transmitter and who are qualified for such work.
The M200 easy transmitter must only be operated under the specified operating conditions
(see section 15 Specifications).
Repair of the M200 easy transmitter must be performed by authorized, trained personnel
only.
With the exception of routine maintenance, cleaning procedures or fuse replacement, as
described in this manual, the M200 easy transmitter must not be tampered with or altered in
any manner.
Mettler-Toledo accepts no responsibility for damage caused by unauthorized modifications
to the transmitter.
Follow all warnings, cautions, and instructions indicated on and supplied with this product.
Install equipment as specified in this instruction manual. Follow appropriate local and
national codes.
Protective covers must be in place at all times during normal operation.
If this equipment is used in a manner not specified by the manufacturer, the protection
provided by it against hazards may be impaired.
WARNINGS:
Installation of cable connections and servicing of this product require access to shock hazard
voltage levels.
Main power and relay contacts wired to separate power source must be disconnected before
servicing.
Switch or circuit breaker shall be in close proximity to the equipment and within easy reach of
the OPERATOR; it shall be marked as the disconnecting device for the equipment.
Main power must employ a switch or circuit breaker as the disconnecting device for the
equipment.
Electrical installation must be in accordance with the National Electrical Code and/or any other
applicable national or local codes.
C NOTE: RELAY CONTROL ACTION: the M200 easy transmitter relays will always de-energize on
loss of power, equivalent to normal state, regardless of relay state setting for powered operation.
Configure any control system using these relays with fail-safe logic accordingly.
C NOTE: PROCESS UPSETS: Because process and safety conditions may depend on consistent
operation of this transmitter, provide appropriate means to maintain operation during sensor
cleaning, replacement or sensor or instrument calibration.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 9
3 Unit overview
M200 easy models are available in both a 1/4DIN and 1/2DIN case size. The 1/4DIN is a
panel-mount only design and the 1/2DIN models provide an integral IP65 housing for wall-, or
pipe-mount.
METTLER TOLEDO
4
3
4.01
5 7 [102]
6
ESC
M200 easy
5
3
5.90
[150]
ESC
6 4
Menu Cal Info Enter
2 7 8
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 10
Measurement
Mode M200 easy
Model/Software
Quick Setup Configure System Service Messages Sensor Info Calibration Data
Revision
Set/Clear
Alarm/Clean
Lockout
Display Reset
Hold Outputs
C NOTE: In order to back up one menu page, without escaping to the measurement mode,
move the cursor under the UP Arrow character () at the bottom right of the display screen and
press [Enter].
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 11
3.3.2.2 Escape
Press the and key simultaneously (escape) to return to the Measurement mode.
3.3.2.3 Enter
Use the key to confirm action or selections.
3.3.2.4 Menu
Press the key to access the main Menu.
C NOTE: Some screens require configuring multiple values via the same data field (ex: configuring
multiple setpoints). Be sure to use the or key to return to the primary field and the or
key to toggle between all configuration options before entering to the next display screen.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 12
3.4 Display
C NOTE: In the event of an alarm or other error condition the M200 easy transmitter will display a
flashing in the upper right corner of the display. This symbol will remain until the condition
that caused it has been cleared.
C NOTE: During calibrations, clean, Digital In with Analog Output/Relay/USB in Hold state,
a flashing H will appear in the upper left corner of the display. This symbol will remain for
20 seconds until after the calibration or clean is completed. This symbol will also disappear
when Digital In is deactivated.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 13
4 Installation instruction
If there is no apparent damage, unpack the container. Be sure all items shown on the packing
list are present.
If items are missing, notify Mettler-Toledo immediately
3.62 +0.02
0
[92 +0.5
0 ]
3.62 +0.02
0
[92 +0.5
0 ]
PANEL CUT-OUT
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 14
MOUNTING SCREW
4.01 [90]
[102]
2 PLACES
3.55
MOUNTING SCREW
9
[90] 8
7
6
5
4
3
2
4.01 1
2 PLACES
[90] 1 2 3 4 5 6 7
6
5
4
3
2
1
USB 1 2 3 4 5 6 7
4.01
[102]
MAX. 0.118
[3]
MOUNTING 4.01 FLAT GASKET
BRACKET [102]
2 PLACES
4.96
[126] 4.92
[125]
MAX. 0.118
[3]
NG FLAT GASKET
ET
ES
4.96
1.77
[126] 4.92 [45]
[125] 4.33
[110] 3.54
[90]
1.77
[45]
4.33
[110] 3.54
[90]
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 15
Below are cut-out dimensions required by the 1/2DIN models when mounted within a flat panel
or on a flat enclosure door. This surface must be flat and smooth. Textured or rough surfaces are
not recommended and may limit the effectiveness of the gasket seal provided.
5.39+0.02
0.00
[137 +0.5
0.0]
5.39+0.02
0.00
PANEL CUT-OUT
[137 +0.5
0.0]
Optional hardware accessories are available that allow for panel- or pipe-mount.
Refer to section 14 Accessories and Spare Parts for ordering information.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 16
2
3
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 17
M200 easy
136 mm / 5.35"
150 mm/ 5.9"
29 mm
6.5 mm
42 mm
0.256"
1.65" 1.14"
84 mm
3.31"
35 mm / 90 mm / 3.54"
1.38" 80 mm / 3.15"
75 mm / 2.95"
138 mm 0.5 mm
5.43" 0.02"
90 mm / 3.54"
0.236"
6 mm /
138 mm 0.5 mm
5.43" 0.02"
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 18
TB4 TB3
92 mm 0.5 mm
Fuse
102 mm / 4.02"
3.62" 0.02"
12
Power TB1A
92 mm 0.5 mm TB1B
3.62" 0.02" USB TB2
102 mm / 4.02"
126 mm / 4.96"
125 mm / 4.92"
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 19
Be sure power to all wires is turned off before proceeding with the installation. High voltage may
be present on the input power wires and relay wires.
A two-terminal connector on the rear panel of all M200 easy models is provided for power
connection. All M200 easy models are designed to operate from a 2030 VDC or a 100 to 240
VAC power source. Refer to specifications for power requirements and ratings and size power
wiring accordingly.
The terminal block for power connections is labeled Power on the rear panel of the transmitter.
One terminal is labeled N for the Neutral wire and the other +L for the Line (or Load) wire.
There is no earth ground terminal on the transmitter. For this reason the internal power wiring
within the transmitter is double insulated and the product label designates this using the h
symbol.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 20
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 21
Power connections are labeled N for Neutral and +L for Line, for 100 to 240 VAC or 20 30 VDC.
1
4 DIN TB2 for 14 DIN TB4 TB3 2 DIN
1
TB2 for 12 DIN
1 AO1+ 9 9 1 AO1+
2 AO1/AO2 2 AO1/AO2
3 AO2+ 3 AO2+
1 1
4 AO3+* 4 AO3+*
5 AO3/AO4* 9 5 AO3/AO4*
6 AO4+* TB1A 6 AO4+* TB1 1 14
7 DI1+ 1 7 7 DI1+
8 DI1/DI2* TB1B 1 8 DI1/DI2* 1 9 1 9 1 9
9 DI2+* 1 7 TB2 9 DI2+* TB2 TB3 TB4
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 22
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 23
A B
C NOTE: Connect the sensor and screw the plug head clockwise (hand tight).
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 24
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 25
6 Quick Setup
(PATH: Menu/Quick Setup)
Select Quick Setup and press the [ENTER] key. Enter the security code if necessary
(see section 9.3 System/Passwords).
C Note: P
lease find the complete description of the Quick Setup routine described in the separate
booklet Quick Setup Guide for Transmitter M200 easy enclosed in the box.
C Note: R
efer to section 3.3 Unit overview / Control/Navigation Keys for information on menu
navigation.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 26
7 Sensor Calibration
(PATH: Cal)
The calibration key [CAL] allows the user one-touch access to Sensor calibration and verification
features. The M200 easy also allows access to Analog Output calibration if the access has been
previously unlocked (see section 10.2 Service / Calibrate).
C NOTE: During Calibration, a flashing H in the upper left corner of the display indicates a
calibration is in process with a Hold condition active. (The hold output function need to be
activated.)
For Multi-channel devices: Using the or key on the Channel A field lets the user change
the channel to be calibrated. Then use the key to move to the calibration field.
Select the desired sensor calibration task. The choices for each sensor type are:
Conductivity = Conductivity, Resistivity, Verify
Oxygen = Oxygen, Verify
pH = pH, Verify
ORP = ORP, Verify
Press [ENTER].
C NOTE: When performing calibration on a conductivity or resistivity sensor, results will vary
depending on the methods, calibration apparatus and/or quality of reference standards used to
perform the calibration.
Enter conductivity sensor calibration mode as described in section 7.1 Enter Calibration Mode.
After selecting the desired sensor calibration and pressing [ENTER], the next screen will ask to
select the type of temperature compensation mode desired during the calibration process.
The choices are Standard, Light 84, Std 75 C, Lin 20 C = 02.0%/C (user selectable
value), Lin 25 C = 02.0%/C (user selectable value), Glycol.5, Glycol1, Alcohol and
Nat H2O.
Press [ENTER].
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 27
C NOTE: Rinse sensors with a high-purity water solution before every calibration to prevent
contamination of the reference solutions.
Enter the Value of calibration Point 1 and then press the [ENTER] key to start calibration.
The value in the 2nd text line is the actual measured value from the sensor prior to calibration.
After the calibration the Multiplier or slope calibration factor M and the Adder or offset
calibration factor A are displayed.
Select Yes to save the calibration values and the Successful Calibration is confirmed on the
display.
The user gets the message Re-install sensor and Press Enter on the display. After pressing
[ENTER] the M200 easy returns to the measuring mode.
C NOTE: Rinse sensors with a high-purity water solution between calibration points to prevent
contamination of the reference solutions.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 28
Enter the Value of Point 1 and press the [ENTER] key. Place the sensor into the second reference
solution.
Enter the Value of Point 2 and press the [ENTER] key to start the calibration.
After the calibration the Multiplier or slope calibration factor M and the Adder or offset
calibration factor A are displayed.
Select Yes to save the calibration values and the Successful Calibration is confirmed on the
display.
The user gets the message Re-install sensor and Press Enter on the display. After pressing
[ENTER] the M200 easy returns to the measuring mode.
Take a sample and press the [ENTER] key again to store the current measuring value.
During the ongoing calibration process, the letter of the channel, which is concerned by the
calibration, A or B is blinking in the display.
After determining the conductivity value of the sample, press the [CAL] key again to proceed with
the calibration.
Enter the conductivity value of the sample then press the [ENTER] key to start the calculation of
calibration results.
After the calibration the Multiplier or slope calibration factor M and the Adder or offset
calibration factor A are displayed.
Select Yes to save the calibration values and the Successful Calibration is confirmed on the
display.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 29
Enter Oxygen Calibration mode as described in section 7.1 Enter Calibration Mode.
A DO sensor calibration is always either a one point Air (Slope) or a Zero (Offset) calibration. A
one point slope calibration is done in air and a one point offset calibration is done at 0 ppb DO.
A one-point zero dissolved oxygen calibration is available but not normally recommended since
zero DO is very hard to achieve.
Select 1 point followed by either Slope or ZeroPt as the calibration type. Press [ENTER].
Enter the value for Point 1 including a decimal point and units. The value in the second text line
is the value being measured by the transmitter and sensor in the units selected by the user.
Press [ENTER] when this value is stable to perform the calibration.
After the calibration the slope calibration factor S and the offset calibration factor Z are displayed.
Select Yes to save the calibration values and the successful Calibration is confirmed on the
display.
The user gets the message Re-install sensor and Press ENTER on the display. After pressing
[ENTER] the M200 easy returns to the measuring mode.
Select Process followed by either Slope or ZeroPt as the calibration type. Press [ENTER]
Take a sample and press the [ENTER] key again to store the current measuring Value. To show
the ongoing calibration process, A or B (depending on the channel) is blinking in the display.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 30
After determining the O2 Value of the sample press the [CAL] key again to proceed with the
calibration. Enter the O2 value of the sample then press the [ENTER] key to start calibration.
After the calibration the slope calibration factor S and the offset calibration factor Z are displayed.
Select Yes to save the new calibration values and the successful Calibration is confirmed on the
display.
7.4 pH Calibration
For pH sensors, the M200 easy transmitter features one-point, two-point (Auto or Manual mode)
or process calibration with 8 preset buffer sets or manual buffer entry. Buffer values refer to
25 C. To calibrate the instrument with automatic buffer recognition, you need a standard pH
buffer solution that matches one of these values. (See section 8.2.3.2 Configuration/
Measurement/ Parameter Related Settings/pH Parameters for configuring modes). Please select
the correct buffer table before using automatic calibration (see chapter 19 Buffer tables).
Depending on the parameterized Drift control (see chapter 8.2.3.2 pH parameters) one of the
two following modes is active.
The display shows the buffer the transmitter has recognized (Point 1) and the measured value.
As soon as the drift conditions have stabilized the display changes to show the slope calibration
factor S and the offset calibration factor Z.
Select Yes to save the calibration values and the successful Calibration is confirmed on the
display.
The user gets the message Re-install sensor and Press Enter on the display. After pressing
[ENTER] the M200 easy returns to the measuring mode.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 31
The display shows now the slope calibration factor S and the offset calibration factor Z.
Select Yes to save the calibration values and the successful Calibration is confirmed on the
display.
The user gets the message Re-install sensor and Press Enter on the display. After pressing
[ENTER] the M200 easy returns to the measuring mode.
Depending on the parameterized Drift control (see chapter 8.2.3.2 pH parameters) one of the
two following modes is active.
The display shows the buffer the transmitter has recognized (Point 1) and the measured value.
As soon as the drift conditions have stabilized, the display changes and prompts you to place
the electrode in the second buffer.
Place the electrode in the second buffer solution and press the [ENTER] key to go on with the
calibration.
The display shows the second buffer the transmitter has recognized (Point 2) and the measured
value.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 32
As soon as the drift conditions have stabilized the display changes to show the slope calibration
factor S and the offset calibration factor Z.
Select Yes to save the calibration values and the successful Calibration is confirmed on the
display.
The user gets the message Re-install sensor and Press Enter on the display. After pressing
[ENTER] the M200 easy returns to the measuring mode.
Place the transmitter in the second buffer solution. The display shows the buffer the transmitter
has recognized (Point 2) and the measured value. Press [ENTER] to proceed.
The display shows the slope calibration factor S and the offset calibration factor Z.
Select Yes to save the calibration values and the successful Calibration is confirmed on the
display.
The user gets the message Re-install sensor and Press Enter on the display. After pressing
[ENTER] the M200 easy returns to the measuring mode.
Take a sample and press the [ENTER] key again to store the current measuring Value. To show
the ongoing calibration process, A or B (depending on the channel) is blinking in the display.
After determining the pH Value of the sample, press the [CAL] key again to proceed with the
calibration.
Enter the pH value of the sample then press the [ENTER] key to start calibration.
After the calibration the slope calibration factor S and the offset calibration factor Z are displayed.
Select Yes to save the new calibration values and the successful Calibration is confirmed on the
display.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 33
Enter the value of calibration Point 1 and then press the [ENTER] key to start calibration.
The value in the 2nd text line is the actual measured value from the sensor prior to calibration.
The display shows the slope calibrations factor S, which is always 1.00000 and the offset
calibration factor Z.
Select Yes to save the calibration values and the successful Calibration is confirmed on the
display.
The user gets the message Re-install sensor and Press Enter on the display. After
pressing [ENTER] the M200 easy returns to the measuring mode.
The measured signal of the primary and the secondary measurement in electrical units
are shown. The meter calibration factors are used when calculating these values.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 34
8 Configuration
(PATH: Menu/Configure)
Configure
8.2 Measurement
(PATH: Menu/Configure/Measurement)
Press the [ENTER] key to select this Menu. The following sub menus can now be selected:
Channel Setup, Comp/pH/O2 and Set Averaging.
pH = pH measurement
O2 hi = Dissolved oxygen (ppm)
Cond (2) = 2 electrode conductivity
Cond (4) = 4 electrode conductivity
ORP = ORP measurement
Auto: = The transmitter automatically recognizes the connected sensor
If you select a specific parameter instead of auto, the transmitter only accepts the selected
parameter type.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 35
The 4 lines of the display can now be configured with sensor channel A or B for each line
of the display as well as measurements and unit multipliers. Pressing the [ENTER] key will
display the selection for lines c and d.
Pressing the [ENTER] key again will bring up the Save Changes dialog. Selecting No will
discard the entered values and return to the measurement display screen, selecting Yes will
save changes made.
Conductivity Conductivity
Sensor Sensor
Reverse Osmosis Membrane
B A
Feed Product
C NOTE: The product monitoring sensor must be on the channel that will measure percent
rejection. If the product conductivity sensor is installed in channel A, then percent rejection must
be measured in channel A.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 36
The calculated CO2 measurement must be configured to the same channel as cation
conductivity. For example, set up measurement a on channel A to be cation conductivity,
measurement b on channel B to be degassed cation conductivity, measurement c on
channel A to be calculated CO2 and measurement d on channel B to be temperature.
Set the temperature compensation mode to Cation for both conductivity measurements.
Enter Configuration Mode as described in section 8.1 Enter Configuration mode and select the
menu Measurement (see section 8.2 Configuration/Measurement).
For dual channel devices: The menu Comp/pH/O2 can be selected by using the or key.
Then use the key to move to the next line and select the parameter. The choices are
Compensation (for conductivity measurement), pH and O2. Press [ENTER]
For single-channel devices: Depending on the connected sensor the following parameter is
shown in the display: Compensation (for conductivity measurement), pH or O2. Press [ENTER]
For more details, please see the following explanations depending on the selected parameter.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 37
The temperature compensation mode for any of the four measurement lines can be selected.
Temperature compensation should be matched to the characteristics of the application.
Choices are Standard, Light 84, Std 75 C, Lin 20 C, Lin 25 C, Nat H2O, Glycol.5,
Glycol1, Cation, Alcohol and Ammonia.
If compensation mode Lin 25 C or Lin 20 C has been chosen, the factor for the adjustment
of the reading can be modified after pressing [ENTER] (If working at measurement line 1 or 2
press [ENTER] twice).
Pressing [ENTER] will bring up the Save Changes dialog. Selecting No will discard the entered
values and return to the measurement display screen, selecting Yes will save changes made.
Standard compensation includes compensation for non-linear high purity effects as well as
conventional neutral salt impurities and conforms to ASTM standards D1125 and D5391.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 38
8.2.3.2 pH Parameters
Select pH and press [ENTER].
Select the Drift control for calibration as Auto (drift and time criteria have to be fulfilled) or
Manual (The user can decide when a signal is stable enough to complete calibration)
followed by the relevant buffer table for the automatic buffer recognition. If the drift rate is less
than 0.8 mV over a 20 second interval then the reading is stable and the calibration is done
using the last reading. If the drift criteria is not met within 300 seconds then the calibration
times out and the message Calibration not done is displayed.
For automatic buffer recognition during calibration, select the buffer solution set that will be used:
Mettler-9, Mettler-10, NIST Tech, NIST Std, HACH, CIBA, MERCK, WTW or None. See section 19
Buffer tables for buffer values. If the auto buffer feature will not be used or if the available
buffers are different from those above, select None.
STC is the solution temperature coefficient in units of pH/C referenced to 25 C (Default = 0.000
for most applications). For pure waters, a setting of 0.016 pH/C should be used. For low
conductivity power plant samples near 9 pH, a setting of 0.033 pH/C should be used. These
positive coefficients compensate for the negative temperature influence on the pH of these
samples.
IP is the isothermal point value (Default = 7.000 for most applications). For specific
compensation requirements or non standard inner buffer value, this value can be changed.
Fixed allows a specific temperature value to be entered. Selecting No means the temperature
given by the digital sensor connected to the channel will be used for the Calibration.
Pressing [ENTER] again will bring up the Save Changes dialog. Selecting No will discard the
entered values and return to the measurement display screen, selecting Yes will save changes
made.
Enter the Calibration pressure. The default value for CalPres is 759.8 and the default unit is
mmHg.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 39
Enter the Process Pressure. The units for ProcPres and CalPres do not have to be the same.
For the algorithm of the process calibration the applied pressure (ProcCalPres) has to be
defined. The value of the process pressure (ProcPres) or the calibration pressure (CalPres)
can be used. Chose the pressure, that applies during the process calibration, resp. should be
used for the algorithm and press [ENTER].
The salinity of the measured solution and the relative humidity of the calibration gas can also be
entered. The allowed values for Relative Humidity are in the range 0% to 100%.
Pressing the [ENTER] key again will bring up the Save Changes dialog. Selecting No will discard
the entered values and return to the measurement display screen, selecting Yes will save
changes made.
Pressing the [ENTER] key again will bring up the Save Changes dialog. Selecting No will discard
the entered values and return to the measurement display screen, selecting Yes will save
changes made.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 40
Go to the menu Analog Output by using the or key. Press the [ENTER] key to select this
Menu, which lets you configure the 2 (4 for dual channel version) Analog Outputs.
Once analog outputs have been selected, use the and buttons to navigate between
configurable parameters. Once a parameter is selected, its setting can be selected per the
following table:
When an Alarm Value is selected, the analog output will go to this value if any alarm condition
occurs.
If Auto-range was selected then Aout max1 can be configured. Aout max1 is the maximum
value for the first range on Auto-Range. The maximum value for the second range on Auto-
Range was set in the previous menu. If Logarithmic Range was selected, it will also prompt
for the number of decades as Aout1 # of Decades =2.
The value for the Hold mode can be configured to hold the Last value or can be set to a Fixed
value.
Pressing the [ENTER] key again will bring up the Save Changes dialog. Selecting No will
discard the entered values and return to the measurement display screen, selecting Yes will
save changes made.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 41
8.4 Setpoints
(PATH: Menu/Configure/Setpoints)
4 (6 for dual channel version) Setpoints can be configured on any of the measurements (a thru
d). The possible Setpoint types are Off, High, Low, Outside and Between.
An Outside Setpoint will cause an alarm condition whenever the measurement goes above its
high limit or below its low limit. A Between Setpoint will cause an alarm condition to occur
whenever the measurement is between its high and low limits.
Enter the desired value(s) for the Setpoint and press [ENTER]
This screen provides the option to configure a setpoint to be active on an over range condition.
Select the setpoint and Yes or No. Select the desired relay that will activate when the setpoint
alarm condition is reached.
Over Range
Once configured, the selected relay will be activated if a sensor over-range condition is detected
on the assigned input channel.
Delay
Enter the delay time in seconds. A time delay requires the setpoint to be exceeded continuously
for the specified length of time before activating the relay. If the condition disappears before the
delay period is over, the relay will not be activated.
Hysteresis
Enter the hysteresis as a percentage-value. A hysteresis value requires the measurement to
return within the setpoint value by a specified percentage before the relay is deactivated.
For a high setpoint, the measurement must decrease more than the indicated percentage
below the setpoint value before the relay is deactivated. With a low setpoint, the measurement
must rise at least this percentage above the setpoint value before the relay is deactivated. For
example, with a high setpoint of 100, when this value is exceeded, the measurement must fall
below 90 before the relay is deactivated.
Hold
Enter the Relay Hold Status of Last, On or Off. This is the state the Relay will go to during a
Hold status.
State
Relay contacts are in normal state until the associated setpoint is exceeded, then the relay is
activated and the contact states change.
Select Inverted to reverse the normal operating state of the relay (i.e. Normally open contacts
are in a closed state, and normally closed contacts are in an open state, until the setpoint is
exceeded). Inverted relay operation is functional when power is applied to the M200 easy
transmitter.
Pressing the [ENTER] key again will bring up the Save Changes dialog. Selecting No will
discard the entered values and return to the measurement display screen, selecting Yes will
save changes made.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 42
8.5 Alarm/Clean
(PATH: Menu/Configure/Alarm/Clean)
8.5.1 Alarm
To select Setup Alarm, press the or key so that Alarm is flashing.
Using the and buttons, navigate to Use Relay #. Using the or keys, select a relay
to be used for the Alarm and press [ENTER].
If any of these criteria are set to Yes and the conditions for an alarm are given, the flashing
symbol will be shown in the display, an alarm message will be recorded (see also chapter 11.1
Messages; PATH: Info/Messages) and the selected relay will be activated. Furthermore an alarm
can be indicated by the current output if this has been parameterized (see chapter 8.3 Analog
Outputs; PATH: Menu/Configure/Analog Outputs).
For 1 and 2 the alarm indicator will be turned off when the alarm message is cleared. It will
reappear if the power is constantly cycling or if the watchdog is repeatedly resetting the system.
Please note, that there are additional alarms, which will be indicated in the display. See therefore
in chapter Troubleshooting the different warning- and alarm lists.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 43
Each Alarm Relay can be configured in either a Normal or Inverted state. In addition, a Delay
for the activation can be set. For more information, refer to section 8.4 Setpoints.
If power failure is turned on, only inverted state is possible and cannot be changed.
Pressing the [ENTER] key again will bring up the Save Changes dialog. Selecting No will
discard the entered values, selecting Yes will make the entered values the current ones.
8.5.2 Clean
Configure the Relay to be used for the cleaning cycle.
The Default value is Relay 1.
The Cleaning Interval can be set from 0.000 to 999.9 hours. Setting it to 0 turns the clean
cycle off. The cleaning time can be 0 to 9999 seconds and must be smaller than the Cleaning
Interval.
Pressing the [ENTER] key again will bring up the Save Changes dialog. Selecting No will
discard the entered values and return to the measurement display screen, selecting Yes will
save changes made.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 44
8.6 Display
(PATH: Menu/Configure/Display)
This Menu allows for the configuration of the values to be displayed and also the configuration
of the Display itself.
8.6.1 Measurement
The Display has 4 lines. Line 1 on top and Line 4 on the bottom.
Select the Error Display mode. If this is set to On when an alarm has occurred, the message
Failure Press Enter will be displayed on Line 4 when an alarm occurs in the normal
Measurement mode.
Pressing the [ENTER] key again will bring up the Save Changes dialog. Selecting No will
discard the entered values, selecting Yes will make the entered values the current ones.
8.6.2 Resolution
This menu allows the setting of the resolution of each displayed value.
Pressing the [ENTER] key will bring up the Save Changes dialog.
8.6.3 Backlight
This Menu allows the setting of the back light options of the display.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 45
Possible settings are On, On 50% or Auto Off 50%. If Auto Off 50% is selected then the
backlight will go to 50% after 4 minutes with no keypad activity. The backlight will automatically
come back on if a key is pressed.
Pressing the [ENTER] key Will bring up the Save Changes dialog.
8.6.4 Name
This menu allows for the configuration of an alpha-numeric name which is displayed in the first
9 characters on Lines 3 and 4 of the Display. The default is nothing (blank).
If a name is entered on line 3 and/or 4 a measurement can be still displayed on the same line.
Use the and keys to navigate between digits to be altered. Using the and keys to
change the character to be displayed. Once all digits of both display channels have been
entered, press [ENTER] to bring up the Save Changes dialog.
The resulting display in the measurement mode appears on Lines 3 and 4 ahead of the
measurements.
The Hold outputs function applies during the calibration process. If set Hold outputs to Yes,
during calibration process the analog output, the output relay and USB ouptut will be at hold
state. The hold state depends on the setting. For the possible hold settings, see the list below.
The following options are possible:
The DigitalIn function applies all the time. As soon as a signal is active on the digital input
the transmitter goes to hold mode and the values on the analog output, the output relays and the
USB output will be at hold state.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 46
9 System
(PATH: Menu/System)
System
While in Measurement mode press the key. Press the or key to navigate to System
Menu and press [ENTER].
9.2 USB
(PATH: Menu/System/USB)
USB Hold may be set to either Off or Last Values. An external host device may poll the
M200 easy for data. If the USB Hold is set to Off, current values are returned. If the USB Hold is
set to Last Values, the values present at the time the hold condition was established are
returned.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 47
9.3 Passwords
(PATH: Menu/System/Passwords)
This Menu allows for the configuration of Operator and Administrator Passwords, as well as
setting up a List of allowed Menus for the Operator. The Administrator has rights to access all
Menus. All default passwords for new transmitters are 00000.
The Passwords Menu is protected: Enter the Administrator Password to enter the Menu.
Press the [ENTER] key and confirm the new password. Press [ENTER] again to bring up the
Save Changed dialog.
Choose either Yes or No to give/deny access to the above Menus and press [ENTER] to advance
to the next items. Pressing the [ENTER] key after configuring all menus will bring up the Save
Changes dialog. Selecting No will discard the entered values, selecting Yes will make the entered
values the current ones.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 48
This menu enables/disables the Lockout functionality of the transmitter. The user will be asked
for a password before being allowed into any menus if the Lockout functionality is enabled.
The Lockout Menu is protected: Enter the Administrator Password and select YES to enable or
NO to disable the Lockout functionality. Pressing the [ENTER] key after the selection will bring up
the Save Changes dialog. Selecting No will discard the entered value, selecting Yes will make
the entered value the current one.
9.5 Reset
(PATH: Menu/System/Reset)
Pressing the [ENTER] key after the selection will bring up a confirmation screen. Selecting No
will return the user to the Measurement mode with no changes. Selecting Yes will reset the meter.
Pressing the [ENTER] key after the selection will bring up a confirmation screen. Selecting No
will return the user to the Measurement mode with no changes. Selecting Yes will reset the
Analog Output calibration.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 49
10 Service
(PATH: Menu/Service)
Service
While in Measurement mode press the key. Press the or key to navigate to the Service
Menu and press [ENTER]. The available system configuration options are detailed below
10.1 Diagnostics
(PATH: Menu/Service/Diagnostics)
This Menu is a valuable tool for troubleshooting and provides diagnostic functionality for the
following items: Model/Software Revision, Digital Input, Display, Keypad, Memory, Set Relays,
Read Relays, Set Analog Outputs, Read Analog Outputs.
By using the key it is possible to navigate forward through this submenu and get additional
information like the current version of software implemented on the transmitter:
Master V_XXXX and Comm V_XXXX); and the version of the sensor firmware (FW V_XXX) and
sensor hardware (HW XXXX).
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 50
10.1.3 Display
All pixels of the display will be lit for 15 seconds to allow troubleshooting of the display. After
15 seconds the transmitter will return to the normal Measuring mode or press [ENTER] to exit
sooner.
10.1.4 Keypad
For keypad diagnostics, the display will indicate which key is pressed. Pressing [ENTER] will
return the transmitter to the normal Measuring mode.
10.1.5 Memory
If Memory is selected then the transmitter will perform a RAM and ROM memory test. Test
patterns will be written to and read from all RAM memory locations. The ROM checksum will
be recalculated and compared to the value stored in the ROM.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 51
0 = Normal
1 = Inverted.
10.2 Calibrate
(PATH: Menu/Service/Calibrate)
This menu has the options to calibrate and the analog outputs and also allows the unlocking of
calibration functionality.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 52
Connect an accurate milliamp meter to the Analog output terminals and then adjust the five
digit number in the display until the milliamp meter reads 4.00 mA and repeat for 20.00 mA.
As the five digit number is increased the output current increases and as the number is
decreased the output current decreases. Thus coarse changes in the output current can be
made by changing the thousands or hundreds digits and fine changes can be made by
changing the tens or ones digits.
Pressing the [ENTER] key after entering both values will bring up a confirmation screen.
Selecting No will discard the entered values, selecting Yes will make the entered values the
current ones.
Selecting Yes means that Meter and Analog Output calibration Menus will be selectable under
the CAL Menu. Selecting No means that only the Sensor calibration is available under the CAL
Menu. Press [ENTER] after the selection to display a confirmation screen.
C Note: This Menu is for Mettler Toledo Service personnel use only.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 53
11 Info
(PATH: Info)
Info
Pressing the key will display the Info Menu with the options Messages, Calibration Data and
Model/Software Revision.
11.1 Messages
(PATH: Info/Messages)
The most recent message is displayed. The up and down arrow keys allow scrolling through
the last four messages that have occurred.
Clear Messages clears all the messages. Messages are added to the message list when the
condition that generates the message first occurs. If all messages are cleared and a message
condition still exists and started before the clear then it will not appear in the list. For this
message to re-occur in the list the condition must go away and then reappear.
Selecting Calibration Data displays the calibration constants for each sensor. Use the up and
down arrow keys to toggle between channels A and B.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 54
By using the key it is possible to navigate forward through this submenu and get additional
information like the current version of software implemented on the transmitter:
Master V_XXXX and Comm V_XXXX; and the version of the sensor firmware (FW V_XXX) and
sensor hardware (HW XXXX).
The displayed information is important for any Service call. Press [ENTER] to return to the
normal measurement mode.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 55
12 Maintenance
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 56
13 Troubleshooting
If the equipment is used in a manner not specified by Mettler-Toledo Thornton, Inc., the
protection provided by the equipment may be impaired.
Review the table below for possible causes of common problems:
If the power consumption of the M200 easy transmitter is too high or a malfunction leads to a
short circuit the fuse will blow. In this case remove the fuse and replace it with one specified
in section 14 Accessories and Spare parts.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 57
Alarms Description
Watchdog time-out SW/System fault
Error pH Slope >103% Slope too big
Error pH Slope <80% Slope too small
Error pH Zero >8.0 pH Zero offset too big
Error pH Zero <6.0 pH Zero offset too small
Error pH Gls Res >2000 MV Glass electrode resistance too big (break)
Error pH Gls Res <5 MV Glass electrode resistance too small (short)
Alarms Description
Watchdog time-out SW/System fault
Error O2 Slope <110 nA Slope too big
Error O2 Slope >30 nA Slope too small
Error O2 ZeroPt >0.6 nA Zero offset too big
Error O2 ZeroPt <0.6 nA Zero offset too small
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 58
Alarms Description
Watchdog time-out SW/System fault
Error ORP ZeroPt >60 mV Zero offset too big
Error ORP ZeroPt <60 mV Zero offset too small
Alarms, which are caused by a violation of the limitation of a setpoint or the range (see chapter
8.4 Setpoints; PATH: Menu/Configure/Setpoint) will also be shown by a flashing symbol and
recorded through the menu point Messages
(PATH: Info/Messages; see also chapter 11.1 Messages).
According to the parameterization of the transmitter the hint Failure Press Enter will be shown
at line 4 of the display if a warning or alarm has occurred (see also chapter 8.6 Display;
PATH: Menu/Configure/Display/Measurement).
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 59
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 60
15 Specifications
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 61
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 62
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 63
16 Default tables
16.1 M200 easy (1-channel instruments)
Parameter Sub parameter Value Unit
Alarm relay 2
diagnostics No
power failure No
software failure No
Disconnect ChA No
Hold mode* Last
delay 1 sec
hysteresis 0
state inverted
Clean relay 1
hold mode* Last
Interval 0 Hrs
clean time 0 Sec
state normal
delay 0
hysteresis 0
Language English
Passwords administrator 00000
operator 00000
Lockout Yes/No No
Analog Out 1 a
2 b
All analog out mode 420 mA
type normal
alarm off
hold mode last value
Set point 1 measurement a
type off
high/low value 0
Relay 2
Set point 2 measurement b**
type off
high/low value 0
Relay 2
Set point 3 measurement _(none)
type off
high/low value 0
Relay _(none)
Set point 4 measurement _(none)
type off
high/low value 0
Relay _(none)
Relay 1 clean
alarm, set point 1,
Relay 2
set point 2
* for analog output signal if relay is switched
** _ (none) if ORP sensor is connected
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 64
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 65
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 66
16.3.1 pH
Parameter Sub parameter Value Unit
pH Buffer Mettler-9
Analog Out 1 a pH
2 a temperature C
All analog out Mode 420 mA
type normal
alarm off
hold mode last value
pH value 4 mA 2 pH
value 20 mA 12 pH
Temperature value 4 mA 0 C
value 20 mA 100 C
Set point 1 measurement a
type off
high value 12 pH
low value 0 pH
relay 2
Set point 2 measurement b (2nd channel: c)
type off
high value 0 (2nd channel:12) C (2nd channel: pH)
low value 0 (2nd channel: 0) C (2nd channel: pH)
relay 2
Resolution pH 0.01 pH
Temperature 0.1 C
Drift control Auto
IP 7.0 pH
STC 0.000 pH/C
Fix CalTemp No
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 67
16.3.2 Oxygen
Parameter Sub parameter Value Unit
Analog Out 1 a oxygen % sat
2 a temperature C
All analog out mode 420 mA
type normal
alarm off
hold mode last value
Oxygen value 4 mA 0 % sat
value 20 mA 100 % sat
Temperature value 4 mA 0 C
value 20 mA 100 C
Set point 1 measurement a
type off
high value 50 % sat
low value 0 % sat
relay 2
Set point 2 measurement b (2nd channel: c)
type off
C (2nd channel:
high value 0 (2nd channel: 50)
% sat)
C (2nd channel:
low value 0 (2nd channel: 0)
% sat)
relay 2
Temperature 0.1 C
V polarization* + 675 mV
CalPres 759.8 mmHg
ProcPres 759.8 mmHg
ProcCalPres CalPres
Salinity 0.0 g/Kg
Humidity 100 %
* not adjustable
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 68
16.3.3 Conductivity
Parameter Sub parameter Value Unit
a conductivity S/cm
Analog Out 1
resistivity MV-cm
2 a temperature C
All analog out mode 420 mA
type normal
alarm off
hold mode last value
0.1 S/cm
Conductivity value 4 mA
10 MV-cm
10 S/cm
value 20 mA
20 MV-cm
Temperature value 4 mA 0 C
value 20 mA 100 C
Set point 1 measurement a
type off
S/cm
high value 00
MV-cm
S/cm
low value 00
MV-cm
relay 2
Set point 2 measurement b (2nd channel: c)
type off
0 C (2nd channel: S/cm)
high value
0 MV-cm
0 C (2nd channel: S/cm)
low value
0 MV-cm
relay 2
conductivity 0.01 S/cm
Resolution
resistivity 0.01 MV-cm
temperature 0.1 C
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 69
16.3.4 ORP
Parameter Sub parameter Value Unit
Analog Out 1 a ORP mV ORP
2 a none
All analog out mode 420 mA
type normal
alarm off
hold mode last value
ORP value 4 mA 500 mV
value 20 mA +500 mV
Set point 1 measurement a
type off
high value +500 mV
low value 500 mV
relay 2
Set point 2 measurement none (2nd channel: c)
type off
high value none (2nd channel:+500) (2nd channel: mV)
low value none (2nd channel:+500) (2nd channel: mV)
relay 2
Resolution ORP auto mV
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 70
17 Warranty
METTLER TOLEDO warrants this product to be free from significant deviations in material and
workmanship for a period of one year from the date of purchase. If repair is necessary and not
the result of abuse or misuse within the warranty period, please return by freight pre-paid and
amendment will be made without any charge. METTLER TOLEDOs Customer Service Dept. will
determine if the product problem is due to deviations or customer abuse. Out-of-warranty
products will be repaired on an exchange basis at cost.
The above warranty is the only warranty made by METTLER TOLEDO and is lieu of all other
warranties, expressed or implied, including, without limitation, implied warranties of
merchantability and fitness for a particular purpose. METTLER TOLEDO shall not be liable for
any loss, claim, expense or damage caused by, contributed to or arising out of the acts or
omissions of the Buyer or Third Parties, whether negligent or otherwise. In no event shall
METTLER TOLEDOs liability for any cause of action whatsoever exceed the cost of the item
giving rise to the claim, whether based in contract, warranty, indemnity, or tort (including
negligence).
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 71
18 Certificate
Mettler-Toledo Thornton, Inc., 36 Middlesex Turnpike, Bedford, MA 01730, USA has obtained
Underwriters Laboratories listing for M200 easy Model Transmitters. They bear the cULus Listed
mark, signifying that the products have been evaluated to the applicable ANSI/UL and CSA
Standards for use in the U.S. and Canada.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 72
19 Buffer tables
M200 easy transmitters have the ability to do automatic pH buffer recognition. The following
tables show different standard buffers that are automatically recognized.
19.1 Mettler-9
Temp (C) pH of buffer solutions
0 2.03 4.01 7.12 9.52
5 2.02 4.01 7.09 9.45
10 2.01 4.00 7.06 9.38
15 2.00 4.00 7.04 9.32
20 2.00 4.00 7.02 9.26
25 2.00 4.01 7.00 9.21
30 1.99 4.01 6.99 9.16
35 1.99 4.02 6.98 9.11
40 1.98 4.03 6.97 9.06
45 1.98 4.04 6.97 9.03
50 1.98 4.06 6.97 8.99
55 1.98 4.08 6.98 8.96
60 1.98 4.10 6.98 8.93
65 1.99 4.13 6.99 8.90
70 1.99 4.16 7.00 8.88
75 2.00 4.19 7.02 8.85
80 2.00 4.22 7.04 8.83
85 2.00 4.26 7.06 8.81
90 2.00 4.30 7.09 8.79
95 2.00 4.35 7.12 8.77
19.2 Mettler-10
Temp (C) pH of buffer solutions
0 2.03 4.01 7.12 10.32
5 2.02 4.01 7.09 10.25
10 2.01 4.00 7.06 10.18
15 2.00 4.00 7.04 10.12
20 2.00 4.00 7.02 10.06
25 2.00 4.01 7.00 10.01
30 1.99 4.01 6.99 9.97
35 1.99 4.02 6.98 9.93
40 1.98 4.03 6.97 9.89
45 1.98 4.04 6.97 9.86
50 1.98 4.06 6.97 9.83
55 1.98 4.08 6.98 9.83
60 1.98 4.10 6.98 9.83
65 1.99 4.13 6.99 9.83
70 1.99 4.16 7.00 9.83
75 2.00 4.19 7.02 9.83
80 2.00 4.22 7.04 9.83
85 2.00 4.26 7.06 9.83
90 2.00 4.30 7.09 9.83
95 2.00 4.35 7.12 9.83
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 73
*Extrapolated
C NOTE: The pH(S) values of the individual charges of the secondary reference materials are
documented in a certificate of an accredited laboratory. This certificate is supplied with the
respective buffer materials. Only these pH(S) values shall be used as standard values for the
secondary reference buffer materials. Correspondingly, this standard does not include a table
with standard pH values for practical use. The table above only provides examples of pH(PS)
values for orientation.
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 74
*Values complemented
*Extrapolated
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
Transmitter M200 easy 75
09/09 Mettler-Toledo AG, CH-8606 Greifensee, Switzerland Transmitter Multiparameter M200 easy
Printed in Switzerland 52 121 501
METTLER TOLEDO Market Organizations
ISO ISO
9001 14001
certified certified