Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

SoR 2021-22 FInal (Part - I, II, III and IV)

Download as pdf or txt
Download as pdf or txt
You are on page 1of 728

Government of Andhra Pradesh

COMMON SCHEDULE OF RATES


AS PER
A.P. REVISED STANDARD
DATA FOR THE YEAR 2021-22
(Effective from 1st June, 2021)

BOARD OF CHIEF ENGINEERS


MASTER INDEX
Sl.N Description Page No.
o. From To
1 Part-I(Water Resources Work 1 46
Items)
2 Part-II (Roads & Bridge Work Items) 1 29
3 Part-IV(Public Health Work Items) 1 118
4 Part-III(Building Work Items) 1 515
5 Annexure-Latest G.O. on Seignorage 1 7
Charges
Office of the Engineer-in-Chief (A.W/I.W)
Water Resources Dept, Vijayawada.

Procs.No.ENC/IW/P&M/EE.1/DEE-3/AEE (N)/ SoR 2021-22/Vol.1 dt: 28.07.2021

Sub: Schedule of Rates for the year 2021-22 with basic rates (excluding GST) (as
per A.P.Revised Standard Data) -Part-I(Water Resources Dept. Works), Part-
2(Road & Bridge Works) and Part-4 (Public Health Works) approved -
Printing& Communication of SoRs - Reg.
Ref: 1. G.O.Ms.No.49,I&CAD (PW:Reforms)Dept., dt:2.3.2009
2. ENC (PH) Lr.No. 146/T4/SoR 2021-22 dt: 07.07.2021.
3. ENC(R&B), Admn & NDB Lr.No.SoR-II/ ENC/ DEC(R)/ EE (TEC)/ DEE 6/AEE2
/2021 dt: 24.06.2021.
4. Commissioner of Labour, Andhra Pradesh, Vijayawada vide Proceedings
no.J / 3984 /2021 dt.29.04.2021 under Minimum Wages Act, 1948.
5. T.O. Lr. No. ENC/ IW/SE (P&M)/ EE.I/ DEE.3/ AEE (N)/ SoR 2021-22/ Vol.I
dt. 26.07.2021
6. ENC (PH) Lr.No. 146/T4/SoR 2021-22 dt:28.07.2021.
7. ENC (R&B),Admin Lr.No.SoR-II/ENC/DCE(R)/ EE(TEC)/ DEE6 /AEE2 /2021
dt: 27. 07.2021.
8. C.E Buildings Vijayawada Lr No.20938/SOR/DCE(B)/EE(B)/DEE(B)/AEE/2021
Dt.20.07.2021.
****
The Government have approved A.P.Revised Standard Data vide ref 1st cited. The
Schedule of Rates with basic rates(excluding GST) as per the A.P.Revised Standard Data for
the year 2021-22 is approved based on the following:
The ENC(R&B) vide ref. 3rd cited has furnished the draft basic rates exclusive of GST
for Roads & Bridge items for the year 2021-22.
The Engineer-in-Chief, Public Health Department has furnished draft basic rates
exclusive of GST for Public Health works items and Public Health Materials vide ref 2nd
cited.
For Water Resources Department work items, the Regional Superintending
Engineers: SE, IC, Dowlaiswaram, SE, IC, Chittoor and SE, IC, Vijayawada have submitted the
draft basic rates of materials. The SE, IC, Guntur has furnished draft rates for Mechanical and
Workshop items. Accordingly, the draft rates for Water Resources Department are prepared.
The labour wages are finalized based on the rates as recommended by Regional
Superintending Engineers duly keeping in view of the minimum wages as declared by the
Commissioner, Labour Department vide ref 4th cited.
Based on the above proposals, the draft Schedule of Rates for the part-I (WR
items), Part-II(Roads & Bridge items) & Part-IV(PH items) are prepared for the SoR year
2021-22 and placed before the annual Board of Chief Engineers(BoCEs) meeting for
approval. The BoCEs has reviewed and finalized the rates of above three parts during the
annual SoR meeting held on 08.07.2021 in the conference hall of Engineer-in-Chief
(A.W/I.W), Vijayawada and by virtual meeting held on 22.07.2021.
The minutes containing the recommendations of the BoCEs, vide reference 5th
cited, are communicated to ENC(R&B) and ENC (PH) for updating the draft rates.
Based on the minutes of meeting, the ENC (PH) and ENC(R&B), Admin have
furnished, vide references 6th and 7th cited above, the final copies of PART-II and PART-IV
respectively for incorporating into SoR-2021-22. Chief Engineer Buildings, Vijayawada has
also submitted the Part-III (Buildings) for SOR 2021-22 vide reference 8th cited.
The procedure for the adoption of Water Resources Department work items, lead
& lift charges (Common to all Departments) is shown in the Annexure-A of SoR.
The approved basic rates (excluding GST) are applicable to the data i.e.,
A.P.Revised Standard Data approved by the Government vide G.O.1st cited.
For Roads & Bridge Works, the rates can be applied for MoRTH data as approved
in the G.O. Ms. No. 2, Transport, Roads and Buildings (R-I) Dept., dt: 12.01.2015.
The lead & lift charges are common to all Engineering Departments. The detailed
calculations are incorporated in the Lead & lift chapter in the WR Works (Part-I) of
A.P.Revised Standard Data.
An unique CFMS code for each material is introduced in SoR 2021-22 for the sake
of user convenience.
No other items other than the items communicated now by this Office shall be
introduced in the SoR 2021-22.
The Heads of Department and Officers mentioned below are authorized to print
the Schedule of Rates for the year 2021-22. Unauthorized printing & selling of the SoR is
strictly prohibited.
Any discrepancies found (or) corrections required in SoR 2021-22 may be brought
to the notice of undersigned for issuing corrections.
The revised rates will come into force with effect from 1st June of 2021.
The receipt of the proceedings may be acknowledged in the 1st instance.
Encl: SoR 2021-22 containing Part-I (Water Resources Dept. works),
Part-II (Roads & Bridge works),
Part-III (Buildings) and Part-IV (Public Health Items).

S Sd/-R.Sathish Kumar,28.07.2021
AEE (N) DEE-3 EE-1 SE/P&M Cell Engineer-in-Chief (A.W/ I.W)
Chairman, BOCE (SoR)
Water Resources Department
I. Copy submitted to the Secretary to Govt., WR Dept., 4th Block, A.P.Secretariat
Buildings, Velagapudi, Amaravathi.
II. Copy communicated to the following Heads of Departments along with enclosures
for information.
1. Engineer-in-Chief (Admn)., Roads & Buildings Department.
2. Engineer-in-Chief, Public Health Department.
3. Engineer-in-Chief, Panchayath Raj Department.
4. Engineer-in-Chief, RWS, Department.
5. Chief Engineer (Buildings & RWS), R&B Department.

III. Copy of Scheduled of Rates 2021-22 with basic rates & Standard data, part-1
(WR Dept. works) communicated to the respective E-mail ids of all the Engineers-
in-Chief, Chief Engineers and Regional Superintending Engineers of Irrigation
circles of Vijayawada, Guntur, Dowlaiswaram and Chittoor of Water Resources
Department for taking necessary action
IV. Copy to DEE (Computers), ENC(AW) for uploading the approved SoR-2021-22
(part-I, Part-II, Part-III & Part-IV) on the Water Resources Department website and
to communicate this proceedings to all the members of the Board of Chief
Engineers through E-mail.

Sd/-R.Sathish Kumar,28.07.2021
Engineer-in-Chief (A.W/I.W)
Chairman, BOCE (SoR)
Water Resources Department.
Important – Read The following
ANNEXURE- A

1) The SPIU(Irrigation), Centre for Good Governance (CGG), Hyderabad has developed
software package linking the basic input data of Irrigation with approved data of Water
Resources work items.
2) The lead and lift charges are common to all Engineering Departments. The detailed
calculations are incorporated in the Lead &Lift charges chapter in the Water Resources
Department works (Part-1) of A.P. Revised standard data.
3) The estimate sanctioning authority shall physically verify each and every Water Resources
work item data incorporated in the estimate with basic input data before sanction of the
estimate. Any lapses or arithmetic errors arising in the sanction of data /estimate due to
adoption of the software package lies entirely on the concerned estimate sanctioning
authority only.
4) Any discrepancies / corrections required for improper basic input data appearing in the
approved data of Water Resources work items in the software package and hard copy of
SoR & Standard data (part-1) may be brought to the notice of undersigned for issuing
corrections.
Sd/-R.Sathish Kumar.dt.28.07.2021
Engineer-in-Chief (A.W/I.W)
Chairman, BOCE(SoR)
Water Resources Department
Index – WR Items (Part-I)
Sl. No. Description Page No.s
From To
1 Preamble 1 4

2 Labour Rates 5 9

3 Material Rates 10 36

4 Conveyance Charges of Materials 37 41

5 Hire Charges of Machinery 42 46


PREAMBLE

1
PREAMBLE

1.0 AREA ALLOWANCES:

A) CORPORATIONS & MUNICIPALITIES:

a) (i) 25% extra over the rates on labour component of works is allowed in all Municipal
Corporation Limits of Andhra Pradesh except Greater Visakhapatnam and
Vijayawada municipal corporations (up to a belt of 12 Kms. from Municipal
Corporation limits) and other corporations as notified by the Government from time
to time.

(ii) 40% extra over the rates on labour component of works for Greater
Visakhapatnam and Vijayawada Municipal Corporation (up to a belt of 12 Kms. from
Municipal Corporation limits).

(iii) 40% extra over the rates on labour component of works for Amaravati Capital
City area(217 sq.km) as declared by the Govt.vide G.O.Ms.No.141,MA&UD (M2)Dept.,
dt:09.06.2015(This is introduced as per the Govt instructions issued in
Govt.memo.No.668755/Reforms/2017 d:14.07.2017).

b) Allow 20% extra over basic rates on labour component of works in all District
Headquarters and the remaining Municipal limits (up to a belt of 12 Kms from
Municipal limits).

c) For works at Tirumala Hills in Chittoor District, 40% extra over the basic rates of
labour component is allowed.

d) For works at Horsely hills in Chittoor District, 30% extra over the basic rates of
labour component is allowed.

e) For works located inside Tirumala Temple, 20% extra over the basic rate of labour
component specified for Tirumala Hills is allowed.

f)For Works located inside T.T.D Temples of Sri Padmavathi Ammavari Temple,
Tiruchanoor, Sri Govindaraja Swamy Temple at Tirupathi, Sri Kapleswara Swamy
Temple, Kapilatheerthm, Tirupathi and Sri Kalyana Venkateswara Swamy Temple,
Srinivasa Mangapuram , 20% extra over the basic rates of labour component for
Tirupathi Municipal Corporation is allowed.
B) JAIL COMPOUNDS:

20% extra is allowed over labour rates for the work in the Jail compounds. Only
equivalent number of Man Mazdoor shall be provided in the Jail premises and no
women Mazdoor are allowed inside.
C) INDUSTRIAL AREA:

a. 20% over basic rates on labour component works allowed for works
situated within 10Kms belt of Industrial area of, Ibrahimpatnam, Vuyyuru,
Jaggaiahpeta in Krishna District, Macherla, Gurajala, Challapalli in Guntur District
Garividi in Vijayanagaram District, Renigunta in Chittoor District and Yerraguntla &
Mangampet in Kadapa District, Hindupur, Tadipatri, Anantapur, Guntakal,
Rayalcheruvu, Yadiki of Anantapur District and Adoni, Dhone,Cement Nagar, Nandyal,
Kurnool, Yemmiganur & Bethamcherla of Kurnool District, Anakapally of
Vishakhapatnam District.

2
D) AGENCY / TRIBAL AREAS:
a) 25% extra is allowed for the works located within the interior Agency / Tribal limits,
i.e. for the works located within & upto16 KMs from any all weather route inside
Agency / Tribal.

b) 40% extra is allowed for the works located within the interior Agency / Tribal limits,
i.e. for the works located beyond 16 KMs from any all weather route inside Agency /
Tribal.

NOTE: 1. No extra percentage is permissible in respect of Forest produce such as


Bamboo, Rellu grass and for all materials obtained from outside the Agency
/ Tribal.

2. The extra percentage under Agency / Tribal areas allowance may be


allowed on the labour component and on the labour charges in the rates for
conveyance of materials.

3. The extra percentage on cost of materials in Agency / Tribal areas can be


allowed on the labour component only, if they are manufactured in the
Agency / Tribal areas itself except Forest produce.

E) GHAT ROADS:

For Ghat Roads steeper than 1 in 20, the length of the road may be taken as
1.5 times the existing length of the road for the purpose of leads only for
conveyance of materials based on the certificate for the Ghat Road given by the
Superintending Engineer concerned.

Foot Note: Under compelling circumstances, the concerned Chief Engineer can
adopt the equivalent length of road as 2 ½ times of actual length.

Note below area allowances:

If more than one area allowance ( such as those ) for (1) Municipalities (2)
Agency / Tribal areas (3) Industrial areas are applicable for a particular
situation, only the maximum out of the allowable percentages is to be
allowed.

EXCAVATION OF TRIAL TRENCHES, TRIAL PITS AND EXCAVATION IN RESTRICTED PLACES:


-

I) EXCAVATION OF TRIAL TRENCHES, TRIAL PITS


AND EXCAVATION IN RESTRICTED PLACES: -

A. TRIAL TRENCHES:

1) Trial trenches of not more than 2 metres in width…25% extra.

3
B. TRIAL PITS:

1) Up to 2 Metres depth … 25% extra


2) 2 Metres to 4 Metres depth … 50% extra
3) 4 Metres to 6 Metres depth … 75% extra
4) 6 Metres to 8 Metres depth … 100% extra
5) 8 Metres to 9 Metres depth … 150% extra
6) More than 9 Metres depth … 200% extra

II) EXCAVATION IN RESTRICTED PLACES:-

I) Foundation of Buildings …. 75% extra

II) For pipe lines where the depth is less ….75% extra
than 1.5 times the width
III) For pipe lines where the depth is 1.5 ….120% extra
times or more than the width

IV) Silt removal in restricted areas such U. ….120% extra


T’s.,Culverts and Syphons
V) Excavation of field channels ….75% extra

VI) For narrow trenches not more than …. 75% extra


2 meters in width and depth not less
than twice the width and for excavation
of road boundary drains, model
sections of canals

VII) High berm cutting of not more than ….50% extra


150 mm average thickness and
sectioning for roads

Note: 1) The extra percentage is allowed over Common item for all earth works (COM-
MWRK- Manual Works) for corresponding soil and Standard data items. It
includes the charges for all lifts and initial lead but does not include dewatering
charges if any in respect of all the items under (A) and (B) above.

2) The above extra percentages in respect of excavation in hard rock for restricted
places are to be allowed for (2/3)rd of the cost and shall not to be allowed in
respect of items involving blasting component which may be taken as 1/3 of the
cost.
3.0 SEIGNIORAGE CHARGES:

The rates of the materials indicated in the SOR are exclusive of Seigniorage
Charges. Appropriate Seigniorage Charges for relevant materials are to be added to
the Unit rate of work item in the estimates as fixed by the Government in
G.O.Ms.No.11 (Industries and Commerce Dept.) dt: 11.02.2020. In case of revision, the
revised rates as fixed by Mines and Geology Department have to be adopted.

4
Part I - Labour Rates-Common SoR 2021-22

LABOUR RATES

5
Part I - Labour Rates-Common SoR 2021-22

LABOUR RATES
S. Rate
Sl No. CFMS CODE for
CATEGORY OF WORKER
2021-22
1 2 3 4

I. SKILLED CATEGORY:
1 LAB-00001 Bar bender 700

2 LAB-00002 Black smith / Tin smith / Rivetor 550

3 LAB-00003 Blaster 645

4 LAB-00004 Carpenter Cl- I 655

5 LAB-00005 Electrician ( Licensed ) 650

6 LAB-00006 Fitter Cl- I 615

7 LAB-00007 Floor Polisher / Tile Layer 550

8 LAB-00008 Foreman 645

9 LAB-00009 Gauge reader 545

LAB-00010 Maistry / Work Inspector with Non-technical 640


10 Qualification SSLC/SSC/HSC
11 LAB-00011 Mason Cl- I / Brick layer Cl- I 585

12 LAB-00012 Mechanic Cl- I 590

13 LAB-00013 Operator Air compressor / DG set 575

14 LAB-00014 Operator Batching plant 650

15 LAB-00015 Operator Bus/Ambulance/ Lorry/ Tanker 630

16 LAB-00016 Operator Concrete / Asphalt mixer 575

17 LAB-00017 Operator Concrete / Asphalt paver 575

18 LAB-00018 Operator Concrete pump / Placer/ ice plant 575

19 LAB-00019 Operator Core drilling machine 645

20 LAB-00020 Operator Crane/ Tower crane/ Cable way 645

21 LAB-00021 Operator Drilling jumbo / Loco / Winch 575

22 LAB-00022 Operator Grouting/ Guniting/ Shotcreting 575

23 LAB-00023 Operator Jackhammer/Pneumatic tamper 575

24 LAB-00024 Operator Pump / Ventilation fan 575

25 LAB-00025 Operator Lathe/Drilling/Shearing machine 645

26 LAB-00026 Operator Bending / Planing machine 575

27 LAB-00027 Operator Road roller


590

6
Part I - Labour Rates-Common SoR 2021-22

S. Rate
Sl No. CFMS CODE CATEGORY OF WORKER for
2021-22
1 2 3 4

28 LAB-00028 Operator Shovel / Scraper / Dozer 645

29 LAB-00029 Operator Spillway / Sluice gate 575

30 LAB-00030 Operator Crusher / Conveyor / Mucker 575

31 LAB-00031 Operator Tipper / Dumper / Transit mixer 645

32 LAB-00032 Operator Concrete vibrator 575

33 LAB-00033 Operator Vibratory plain / pad foot roller 575

34 LAB-00034 Operator Wagon drill / Drifter 645

35 LAB-00035 Painter Cl- I 655

36 LAB-00036 Plumber / Pipe fitter 655

37 LAB-00037 Sarang / Khalasi 575

38 LAB-00038 Spun pipe moulder 575

39 LAB-00039 Stone chiseller CI- I / Stone cutter Cl- l 580

40 LAB-00040 Struct. steel Fabricator / Marker / Erector 700

41 LAB-00041 Welder / Gas Cutter 575

42 LAB-00042 Welder (X-ray quality) 645

II. SEMI SKILLED CATEGORY:


1 LAB-00057 Asphalt Sprayer / Boiler attendant 525

2 LAB-00058 Bhisti 525

3 LAB-00059 Boatman with boat 525

4 LAB-00060 Carpenter Cl- II / Erector shuttering 525

5 LAB-00061 Cartman with double bullock cart 585

6 LAB-00062 Cartman with single bullock cart 550

7 LAB-00063 Chavali / Navagani 525

8 LAB-00064 Crowbarman / Jumper man 525

9 LAB-00065 Fitter Cl- II 525

10 LAB-00066 Gang man / Head / Survey mazdoor 525

11 LAB-00067 Gardener / Trained mali 525

12 LAB-00068 Air compressor / DG set 525

13 LAB-00069 Helper Batching plant 525

14 LAB-00070 Helper Blasting 525

7
Part I - Labour Rates-Common SoR 2021-22

S. Rate
Sl for
CFMS CODE CATEGORY OF WORKER
No. 2021-22
1 2 3 4
15 LAB-00071 Helper Bus/ Ambulance/ Lorry/ Tanker 525

16 LAB-00072 Helper Bending/Shearing/Planing machine 525

17 LAB-00073 Helper Carpenter 525

18 LAB-00074 Helper Concrete / Asphalt mixer 525

19 LAB-00075 Helper Concrete / Asphalt paver 525

20 LAB-00076 Helper Core drilling machine 525

21 LAB-00077 Helper Crane/ Tower crane/ Cable way 525

22 LAB-00078 Helper Drilling jumbo / Loco / Winch 525

23 LAB-00079 Helper Fitter / Fabrication/Electrician 525

24 LAB-00080 Helper Grouting/ Guniting/ Shotcreting 525

25 LAB-00081 Helper Jack hammer / Pneumatic tamper 525

26 LAB-00082 Helper Laboratory / Instrumentation 525

27 LAB-00083 Helper Road roller 525

28 LAB-00084 Helper Shovel / Scraper / Dozer 525

29 LAB-00085 Helper Crusher / Conveyor / Mucker 525

30 LAB-00086 Helper Tipper / Dumper/ Transit mixer 525

31 LAB-00087 Helper Vibrator 525

32 LAB-00088 Helper Vibratory plain/ pad foot roller 525

33 LAB-00089 Helper Wagon drill/ Drifter 525

34 LAB-00090 Lineman Electric / Telephone 525

35 LAB-00091 Mason Cl- ll / Brick layer Cl-II 525

36 LAB-00092 Mechanic Cl- II 525

37 LAB-00093 Painter Cl- II 525

38 LAB-00094 Patkari / Neeraganti / Sowdy 525

39 LAB-00095 Stone Chiseller Cl- II 525

40 LAB-00096 Stone breaker / Hammer man 525

41 LAB-00097 Valve man / Canal sluice operator 525

III. UN-SKILLED CATEGORY:


1 LAB-00118 Cement / Asphalt handling mazdoor 490

2 LAB-00119 Civic worker 490

3 LAB-00120 Man mazdoor 490

8
Part I - Labour Rates-Common SoR 2021-22

S. Rate
Sl No. CFMS CODE CATEGORY OF WORKER for
2021-22

1 2 3 4
4 LAB-00121 Woman mazdoor 490

5 LAB-00122 Watchman 490

IV. OTHER CATEGORY:


1 LAB-00124 Care-taker / conductor / Lift Attender 525
2 LAB-00125 Cook / Mess man 525
3 LAB-00126 Dhobi 525
4 LAB-00127 Diploma Engineer / Surveyor 910
5 LAB-00128 Diver with headgear 670
6 LAB-00129 Graduate / Laboratory Assistant 670
7 LAB-00130 Graduate Engineer/ Geologist 1,170
8 LAB-00131 Horticulture Assistant / Photographer 540
9 LAB-00132 ITI certificate holder / Tracer / Printer 655
10 LAB-00133 Literate mazdoor 505
11 LAB-00134 Stenographer / Computer Operator 715
12 LAB-00135 Telephone / Wireless Operator 645
13 LAB-00136 Typist / Job Typist 645
CAD operator with Diploma in
910
14 LAB-00137 Engineering/General degree with CAD certificate
15 LAB-00138 Jeep Driver 640
16 LAB-00139 Data Processing Operator 875

Note: - 1)The wage should not be less than the minimum wages of schedule of
employment, subject to out turn. 2) 25% extra over the corresponding labour rates in respect of
the work to be done during night time subject to issue of certificate accordingly by the
concerned estimate sanctioning authority for providing in the data and by concerned
Executive Engineer in charge of the work for payment. The night time allowance is applicable
only to the works done under Greater Visakhapatnam Municipal Corporation and Vijayawada
Municipal Corporation limits only.

9
Part I-Basic Input data for WR Work items – Common SoR 2021-22

BASIC INPUT DATA


FOR
WATER RESOURCES
WORK ITEMS

10
Part I-Basic Input data for WR Work items – Common SoR 2021-22

STATEMENT OF RATES FOR MATERIALS


FOR THE YEAR: 2021-22
GENERAL GUIDE LINES FOR REVISING RATES OF MATERIALS:

1. Average of the prevailing market rates, ignoring freak rates, is the criteria for
Fixing market rates for materials.
2. The rates for materials are exclusive of GST, duties and other local levies.

3 The rates for materials are exclusive of Seigniorage charges wherever applicable.
4 The rates for materials, except those for which lead charges are admissible as per the
Statement of lead charges is for all leads.
5. The rates provided for useful rubble / stone chips from excavation shall be at dump yard.
6. Unless otherwise specified the rate of materials are inclusive of loading charges.

S. Rate
Sl No. for
CFMS CODE DESCRIPTION OF MATERIAL UNIT
2021-22
1 2 3 4 5
1 MAT-00001 Acetylene gas cum 350

2 Asphalt 80/100 Grade Kg 44


MAT-00002
MAT-00003 Binding wire Kg 64
3
4 MAT-00004 Burnt stone slab 10 cm thick sqm 324
Cement 43 Gr/53 Gr
MAT-00005 Note: Rate as fixed by the Government 3,680
5 tonne

6 MAT-00006 Chequered plate Kg 61

7 MAT-00007 Coarse aggregate 10-4.75 mm cum 967

8 MAT-00008 Coarse aggregate 20-10 mm cum 1,313

9 MAT-00009 Coarse aggregate 40-20 mm cum 1,265

10 MAT-00010 Coarse aggregate 80-40 mm cum 697


The aggregate rates mentioned above (from
Sl.No.7 to Sl.No.10) are exclusive of
Seigniorage charges but including blasting
charges of Rs.70/cum and 25% machine
crushing charges. However, if the metal is
obtained from hand broken, the blasting and
crushing charges shall be deducted. The
aggregate shall be HB Stone of Granite,
Dolamite, Dolerite and Trap. (Quartzite and
Basalt with aggregate impact of less than 20)

48
11 MAT-00011 Coir brush Each
11
Part I-Basic Input data for WR Work items – Common SoR 2021-22

S. Rate
Sl No. for
CFMS CODE DESCRIPTION OF MATERIAL UNIT
2021-22
1 2 3 4 5

12 MAT-00012 Copper sheet 16 SWG Kg 708

13 MAT-00013 Coursed rubble stone 30 x 30 x 45 cm Each 27

14 MAT-00014 Coursed rubble stone 30 x 30 x 60 cm Each 30

15 MAT-00015 Curing Compound Ltr 130

16 MAT-00016 D – cord Rm 7

17 MAT-00017 Delay - noiseless trunk Each 19

18 MAT-00018 Detonating fuse coil Rm 8

19 MAT-00019 Detonating shock tube / Cord relays Rm 37

20 MAT-00020 Detonator delay type Each 20

21 MAT-00021 Detonator electric Each 10

22 MAT-00022 Detonator ordinary Each 7

23 MAT-00023 Empty cement bag Each 6

24 MAT-00024 Explosive ANFO Kg 44

25 MAT-00025 Explosive ANFO high strength booster Kg 69

26 MAT-00026 Explosive small dia ( Kelvex-220 or equivalent) Kg 69

MAT-00027 (a)Fine aggregate/ sand(un- screened) for 605


Concrete & Filtering items) Cum

27
(b)Fineaggregate/Sand(un
MAT-00028 460
screened)for filling Cum
Fine aggregate /Sand (Screened) for
Mortar ,Plastering items and Sand blasting
items (Rs.95 is added towards screening
700
28 MAT-00029 Charges) Cum

29 MAT-00030 Geo-textile ( filter fabric ) 160 gsm Sqm 91

30 MAT-00031 Geo-textile ( filter fabric ) 200 gsm Sqm 108

31 MAT-00032 Geo-textile ( filter fabric ) 250 gsm Sqm 122


G I Pipe 100 mm dia B Class
32 MAT-00033 Rm 762

G I Pipe 15 mm dia A class


33 MAT-00034 Rm 92

12
Part I-Basic Input data for WR Work items – Common SoR 2021-22

S. Rate
Sl No. DESCRIPTION OF MATERIAL for
CFMS CODE UNIT
2021-22

1 2 3 4 5

34 MAT-00035 G I pipe 25 mm dia A class Rm 155

35 MAT-00036 G I pipe 40 mm dia B class Rm 237

36 MAT-00037 G I pipe 50 mm dia A class Rm 277

37 MAT-00038 G I Pipe 80 mm dia B Class Rm 512

38 MAT-00039 G.I Bolts / Nuts and Washers Kg 108

39 MAT-00040 G.I sheet ( plain ) tonne 60,000

40 MAT-00041 Hariyala turfing sods Sqm 28

41 MAT-00042 Hectometer stone one line dressed Each 304

42 MAT-00043 Hemp yarn Kg 79

43 MAT-00044 Honne wood planks Cum 46,000

44 MAT-00045 Hume pipe with collar 150 mm dia Rm 277

45 MAT-00046 Hume pipe with collar 300 mm dia Rm 571

46 MAT-00047 J- Bolts 30 cm long Each 41

47 MAT-00048 Jungle wood planks Cum 19,638

48 MAT-00049 Khandki stone 15 to 20 cm height Each 14

49 MAT-00050 Khandki stone 20 to 25 cm height Each 19

50 MAT-00051 Khandki stone 25 to 30 cm height Each 20

51 MAT-00052 Kilometer stone one line dressed Each 539

52 MAT-00053 LDPE sheet ( Geo membrane ) 500 micron thick Sqm 94

53 MAT-00054 LDPE sheet ( Geo membrane ) 750 micron thick Sqm 134

54 MAT-00055 LDPE sheet ( Geo membrane ) 1000 micron thick Sqm 187

55 MAT-00056 M S Bolts / Nuts / Washers Kg 86

56 MAT-00057 Murrum Cum 215

57 MAT-00058 Oxalic acid Ltr 76

58 MAT-00059 Oxygen gas Cum 43


44
59 MAT-00060 PVC sealing strip Rm

13
Part I-Basic Input data for WR Work items – Common SoR 2021-22

S. Rate
Sl No. for
CFMS CODE DESCRIPTION OF MATERIAL UNIT
2021-22

1 2 3 4 5

60 MAT-00061 PVC water stopper 310 mm wide Rm 459

61 MAT-00062 PVC pipe of 100 mm dia Rm 164


Reinforcement steel (HYSD/TMT )
62 MAT-00063 Note: As per Monthly rate fixed by Sub- 52,500
tonne
Committee
63 MAT-00064 Resin bond Cement capsule Each 48

MAT-00065 Rough stone 20 x 20 x 75 cm 27


64 Each
MAT-00066 Shahabad stone slab 266
65 Sqm
MAT-00067 Stone chips (at dump yard/Spoil) 209
66 Cum
MAT-00068 Stone chips ( at quarry ) 385
67 Cum
Structural steel angle / channel / beam / bars
Note: As per Monthly rate fixed by Sub-
MAT-00069 50,500
Committee
68 Tonne
Structural steel plate / flats
Note: As per Monthly rate fixed by Sub-
MAT-00070 52,000
69 Committee Tonne

Super Plasticizer (Conplast RP-264 or equivalent


70 MAT-00071 Kg 55
)
71 MAT-00072 Synthetic Enamel paint 1st quality Ltr 238

72 MAT-00073 Synthetic adhesive ( Resin + Hardener ) Kg 331

73 MAT-00074 Tar felt joint filler board 12 mm thick Sqm 385

74 MAT-00075 Tar felt joint filler board 20 mm thick Sqm 593


Through stones 20 x 20 x 30 to 45 cm
MAT-00076 24
75 Each
76 MAT-00077 Through stones 25 x 25 x 45 to 60 cm long Each 43

77 MAT-00078 Through stones 30 x 30 x 65 to 75 cm long Each 65


Un-coursed rubble stones ( at dump yard
78 MAT-00079 Cum 181
/Spoil)
79 MAT-00080 Un-coursed rubble stones ( at quarry) Cum 359

80 MAT-00081 Water proofing compound Kg 79

81 MAT-00082 Welding electrodes 4 mm dia Each 14

82 MAT-00083 Wire brush Each 42

14
Part I-Basic Input data for WR Work items – Common SoR 2021-22

S. Rate
Sl No. for
CFMS CODE DESCRIPTION OF MATERIAL UNIT
2021-22
1 2 3 4 5

83 MAT-00084 Wire mesh 20 gauge sqm 235

84 MAT-00085 Zinc chromate red oxide primer paint Ltr 169

85 MAT-00086 inorganic zinc silicate Ltr 574

86 MAT-00087 solvent less coal tar epoxy paint Ltr 280

87 MAT-00088 Zinc phosphate primer Ltr 212


MAT-00089
88 Allkyd based iron oxide paint Ltr 161
MAT-00090
a) Cost of hdpe (90mm dia) Rm 217

b) light black MS casing pipe


89 MAT-00091 471
100 mm dia (4mm thick) Rm

90 MAT-00092 welded steel wire fabric 100X100X5 mm size Kg 193

91 MAT-00093 Protective Mastic Ltr 472

92 MAT-00094 Solventless coal tar epoxy (brown) Ltr 292

15
Part I-Basic Input data for WR Work items – Common SoR 2021-22

ADDITIONAL MATERIALS FOR GATES & HOISTS


FOR THE YEAR: 2021-22
GUIDE LINES:
a) For cast steel / Alloy steel / Forged steel / Bronze, aluminum alloy components the rates shall be
inclusive of cost of basic metal for these components, casting / forging charges, machining
charges and applicable excise duty on finished alloy component.
b) For other materials the rates shall be of prevailing market rates.

S. Rate
for
Sl No. CFMS CODE DESCRIPTION OF MATERIAL UNIT
2021-22
1 2 3 4 5

1 MAT-00108 Alloy steel ( IS : 1570-carbon steel ) shafts Kg 235

2 MAT-00109 Alloy steel ( IS : 1570-stainless steel ) pins Kg 434

3 MAT-00110 Bolt / Nut / Washer ( hot dipped galvanized ) Kg 142

4 MAT-00111 Bolt / Nut / Washer ( stainless steel ) Kg 368


Bronze/Aluminum
5 MAT-00112 Kg 962
alloy(IS:305)bearings/bushes
6 MAT-00113 Cast iron blocks Kg 85

7 MAT-00114 Cast steel drums / gears Kg 233

8 MAT-00115 Cast steel pinions Kg 224


Cast steel wheels / pulleys / hubs /
9 MAT-00116 Kg 193
rollers / Retainers
Chemical for de-greasing/ de-
10 MAT-00117 Ltr 129
rusting/phosphate Coating
11 MAT-00118 Coal tar epoxy paint Ltr 192

12 MAT-00119 Forged steel hooks / shackles Kg 274

13 MAT-00120 MS pipe 200 / 300 mm dia Kg 175

14 MAT-00121 MS pipe 32 mm dia Rm 187

15 MAT-00122 MS pipe 25 mm dia Rm 157

Rubber bottom seal ( IS : 11855 )


16 MAT-00123 Rm 670
(100mmX14 mm)
Rubber side seal ( music note type Teflon claded ) (
17 MAT-00124 1,430
IS : 11855 ) (36ØX113mmX14mm) Rm
Rubber side seal ( music note type uncladed ) ( IS :
1,068
18 MAT-00125 11855 ) Rm
(36ØX113mmX14mm)

16
Part I-Basic Input data for WR Work items – Common SoR 2021-22

S. Rate
for
Sl No. CFMS CODE DESCRIPTION OF MATERIAL UNIT
2021-22
1 2 3 4 5
Rubber side seal Z-type ( IS : 11855 )
19 MAT-00126 Rm 1,372
(36ØX120mmX19mm)
Rubber corner seal ( Teflon claded ) ( IS : 11855 )
20 MAT-00127 Each 1,429
(36Ø)
Rubber corner seal ( un claded )
21 MAT-00128 Each 1,007
( IS : 11855 ) (36Ø)
22 MAT-00129 Stainless steel plates / flats Kg 289
Welding electrode 4 mm dia x 450 mm (
23 MAT-00130 Each 19
radiographic low hydrogen )
Welding electrode 4 mm dia x 450 mm (
24 MAT-00131 Each 23
stainless steel )
25 MAT-00132 Wire rope 6x37 constn ( IS : 2266 ) Kg 203

26 MAT-00133 Zinc Kg 190

27 MAT-00134 Zinc rich ( zinc content : 90 % ) epoxy primer Ltr 613

MATERIALS FOR POWER SUPPLY WORKS


FOR THE YEAR : 2021-22

S. Rate for
Sl
Description of Material Unit 2021-22
No.

1 Electric pole with fixtures Each

2 Flood light 500 W Each

3 Flood light set Each

4 Flouscent tube light 40 W Each


For establishing
5 Flouscent tube light set Each Electrical Sub-
Stations at the
6 HT / LT Circuit breaker with accessories Set Project Sites
HT / LT Line conductor 1000 m wherever
7
necessary, the rates
PVC Armoured cable 10 approved by
Rm
8 sqmm and below APTRANSCO may
be followed.
9 PVC Armoured cable 16 sqmm Rm
10 PVC Armoured cable 25 sqmm Rm

11 PVC Armoured cable 70 sqmm Rm

17
Part I-Basic Input data for WR Work items – Common SoR 2021-22

DETAILS OF CAPITAL COST OF MACHINERY / EQUIPMENT FOR THE


YEAR: 2021-22
GUIDE LINES FOR FIXING CAPITAL COST OF MACHINERY / EQUIPMENT:

1. The Capital cost of machinery / equipment shall be for new machinery / equipment and
shall be exclusive of GST, duties and other levies.
2. The cost of transport vehicles / equipment shall be exclusive of cost of tyres and tubes.
3. The cost of drill rods / drill bits / air hose / water hose / road tax / insurance charges and
Other consumable accessories shall not be included in the capital cost.
4. In cases, where the current capital cost of machinery / equipment could not be collected
through enquiries, the capital cost considered for previous year may be updated on the
basis of average percentage increase / decrease in the index for machinery published in the
R.B.I Bulletin.
S. Rate
Sl
CFMS CODE DESCRIPTION OF MACHINERY / EQUIPMENT UNIT for
No:
2021-22
1 2 3 4 5
Agitator car / Transit mixer 2 cum
1 MAT-00600 Each 19,76,580
( excluding tyres )
MAT-00601 tyres and tubes 6 sets 76,156
2 MAT-00602 Air compressor 5 cmm electric Each 6,23,340
3 MAT-00603 Air compressor 7 cmm diesel Each 8,33,222
4 MAT-00604 Air compressor 7 cmm electric Each 7,78,475
5 MAT-00605 Air compressor 8.5 cmm diesel Each 9,70,032
6 MAT-00606 Air compressor 8.5 cmm electric Each 10,01,587
7 MAT-00607 Air compressor 15 cmm electric Each 12,21,158
8 MAT-00608 Angle Dozer 90 hp Each 50,33,448
Batching plant 0.5 cum with accessories
9 MAT-00609 Each 11,15,414
(6 Cum/hr)
Batching plant 2 x 1.00 cum with accessories ( 15
10 MAT-00610 Each 39,45,736
Cum/hr)
Batching plant 2 x 1.50 cum with accessories ( 50
11 MAT-00611 Each 60,42,093
Cum/hr)
12 MAT-00612 Bending machine Each 5,12,030
13 MAT-00613 Clam shell and hoisting ropes Each 29,230
14 MAT-00614 Concrete bucket 1.5 cum Each 51,087
15 MAT-00615 Concrete hand mixer 45/30 ltr Each 14,520
16 MAT-00616 Concrete mixer 300/200 ltr(diesel) Each 1,36,407
17 MAT-00617 Concrete mixer 300/200 ltr ( electric ) Each 1,33,305
18 MAT-00618 Concrete mixer 600/400 ltr(diesel) Each 2,32,260
19 MAT-00619 Concrete mixer 600/400 ltr ( electric ) Each 2,27,520

18
Part I-Basic Input data for WR Work items – Common SoR 2021-22

S. Rate
Sl
CFMS CODE DESCRIPTION OF MACHINERY / EQUIPMENT UNIT for
No:
2021-22
1 2 3 4 5
20 MAT-00620 Concrete paver 100 Sqm / hr Each 21,91,860
21 MAT-00621 Convey mucker ( excluding tyres ) Each 35,38,464
MAT-00601 tyres and tubes 6 sets 76,156
22 MAT-00622 Core drilling machine Each 10,11,282
23 MAT-00623 Diesel generating set 30 KVA Each 4,60,305
24 MAT-00624 Diesel generating set 50 KVA Each 5,74,942
25 MAT-00625 Diesel Loco 45 hp Each 19,49,024
26 MAT-00626 Dewatering pump 5 hp diesel Each 37,117
27 MAT-00627 Dewatering pump 5 hp electric Each 23,031
28 MAT-00628 Dewatering pump 10 hp diesel Each 56,015
29 MAT-00629 Dewatering pump 10 hp electric Each 51,249
30 MAT-00630 Dewatering pump 20 hp diesel Each 1,77,380
31 MAT-00631 Dewatering pump 20 hp electric Each 96,555
32 MAT-00632 Drifter Each 9,74,808
33 MAT-00633 Drilling jumbo ( excluding tyres ) Each 12,31,198
MAT-08524 tyres and tubes 6 sets 79,000
34 MAT-00634 Dumper 4.5 cum ( excluding tyres ) Each 13,74,258
MAT-00601 tyres and tubes 6 sets 76,156
35 MAT-00635 Geophysical Ele.resistivity meter Each 4,72,525
36 MAT-00636 Grouting pump Each 90,471
37 MAT-00637 Guniting / sand blasting equipment Each 2,85,075
38 MAT-00638 Ice plant with accessories 30 t / day Each 23,58,141
39 MAT-00639 Jack hammer Each 59,513
40 MAT-00640 Needle vibrator 40 mm petrol Each 18,433
41 MAT-00641 Needle vibrator 40 mm electric Each 19,329
42 MAT-00642 Needle vibrator 60 mm petrol Each 19,171
43 MAT-00643 Needle vibrator 60 mm electric Each 23,648
44 MAT-00644 Planing machine 4 m stroke Each 7,81,972
45 MAT-00645 Plate shearing machine up to 12 mm Each 4,26,077
46 MAT-00646 Pneumatic placer 0.5 cum Each 5,33,229

47 MAT-00647 Pneumatic tamper Each 78,473

19
Part I-Basic Input data for WR Work items – Common SoR 2021-22

S. Rate
Sl
CFMS CODE DESCRIPTION OF MACHINERY / EQUIPMENT UNIT for
No:
2021-22
1 2 3 4 5
48 MAT-00648 Pug cutting machine Each 16,753
49 MAT-00649 Pusher leg Each 50,876
50 MAT-00650 Road roller diesel 10 t Each 8,03,780
51 MAT-00651 Shovel 0.50 cum 75 hp Each 35,44,467
52 MAT-00652 Shovel 0.85 cum 110 hp Each 59,21,331
53 MAT-00653 Stationery derrick crane 5 t Each 6,00,336
54 MAT-00654 Tipper 5 cum ( excluding tyres ) Each 15,36,118
MAT-00601 tyres and tubes 6 sets 76,156
55 MAT-00655 Tipping tub 1.5 cum Each 2,22,745
56 MAT-00656 Tower crane 5 tonne Each 68,72,153
57 MAT-00657 Transformer 250 KVA Each 4,56,620

MAT-00658 Truck 10 t ( excluding tyres ) Each 13,56,046


58
MAT-00601 tyres and tubes 6 sets 76,156
Truck mounted derrick crane 5 t
59 MAT-00659 Each 18,77,562
( excluding tyres )
MAT-00601 tyres and tubes 6 sets 76,156
60 MAT-00660 Upright drilling machine Each 52,203
61 MAT-00661 Ventilation fan 20 hp Each 2,70,588
62 MAT-00662 Vibratory pad foot roller 8 t Each 27,89,580
63 MAT-00663 Wagon drill Each 6,08,960
64 MAT-00664 Water tanker 8000 ltr (excluding tyres) Each 14,20,570
MAT-00601 tyres and tubes 6 sets 76,156
65 MAT-00665 Welding set Each 47,405
66 MAT-00666 Winch 35 hp electric Each 3,71,031
67 MAT-00667 Hydraulic Truck Crane 30T Each 1,42,91,558
MAT-08525 tyres and tubes 6 sets 1,70,541
68 MAT-00668 Hydraulic Truck Crane 16T Each 99,09,104
MAT-08526 tyres and tubes 6 sets 1,65,017
4,61,092
69 MAT-00669 Heavy Duty Airless Spray Painting Equipment Each
29,85,550
70 MAT-00670 Concrete Placer Pump(25 Cum/hr)(Electric) Each

20
Part I-Basic Input data for WR Work items – Common SoR 2021-22

ACCESSORIES TO MACHINERY / EQUIPMENT FOR THE YEAR: 2021-22

S Rate
Sl for
CFMS CODE DESCRIPTION OF MATERIAL UNIT
No. 2021-22
1 2 3 4 5

1 MAT-00671 Casing shoe bit Each 10,680

2 MAT-00672 Diamond core bit BX size Each 10,895

3 MAT-00673 Diamond core bit NX size Each 13,080

4 MAT-00674 Double tube core barrel Each 13,945

5 MAT-00675 Extension drill rod with coupling sleeve Rm 1,980

6 MAT-00676 Jack hammer drill rod 1.5 m Each 3,902

7 MAT-00677 Jack hammer drill rod 2.5 m Each 5,840

8 MAT-00678 Nozzle for Guniting / sand blasting gun Each 650

9 MAT-00679 Paving Cylinder Each 28,590

10 MAT-00680 Rails 30R ( 30 kg / m ) tonne 52,945

11 MAT-00681 Reamer shell Each 5,240

12 MAT-00682 T.C. Cross bit 50 mm dia Each 5,140

13 MAT-00683 T.C. Cross bit 75 mm dia Each 10,280

14 MAT-00684 T.C. Cross bit 100 mm dia Each 12,100

15 MAT-00685 Tyres and Tubes for truck Set 14,750

16 MAT-00686 Wire rope 16 mm dia Rm 281

17 MAT-00687 Excavation of drain with Excavator Cum 39

21
Part I-Basic Input data for WR Work items – Common SoR 2021-22

AGGREGATE CRUSHING & PROCESSING PLANT


CFMS S Rate for
Sl No. DESCRIPTION OF MATERIAL UNIT
CODE 2021-22
1 2 3 4 5
Jaw crusher 900 x 500 mm ( 120 tph ) with 50 hp
1 Each
Motor
Jaw crusher 500 x 300 mm ( 60 tph ) with 30 hp
2 Each
Motor
Jaw crusher 400 x 225 mm ( 10 tph ) with 25 hp These items are no
3 Each
Motor where being used
4 Jaw plates 900 x 500 mm ( serreted ) Set in the
Standard Data.
5 Jaw plates 500 x 300 mm ( serreted ) Set Hence
this may be
6 Jaw plates 400 x 225 mm ( serreted ) Set deleted from SoR

7 Nylon Conveyor belt 3 ply 600 mm width Rm

8 Nylon Conveyor belt 3 ply 1000 mm width Rm

OTHER COSTS ON MATERIAL / MACHINERY / EQUIPMENT


FOR THE YEAR: 2021-22
1. The rate provided for ' SUNDRIES' (Lump sum provision for unquantified inputs in the data
rates) shall be updated on the basis of general percentage increase / decrease in the market
rates or on the basis of R.B.I ' All Commodity' index.
2. The rate for structural steel fabrication shall include cost of all materials (except structural steel),
machinery, labour and one coat of primer painting.
3. Demand charges and electric power charges shall be as per prevailing APEPDCL tariff.
4. Rate of interest on capital cost shall be as approved by Govt or other competent authority.

S Rate
Sl DESCRIPTION OF MATERIAL
CFMS CODE UNIT for
No.
2021-22
1 2 3 4 5
1 MAT-00688 Air hose 25 mm dia Rm 176

2 MAT-00689 Air hose 50 mm dia Rm 266


Demand charges (HT-I : General-11 KV
category) on power supply(as per APEPDCL KVA /
475
3 MAT-00690 tariff) month

4 MAT-00691 Diesel Ltr 94.43


Electric power (HT-VIII Category) including tax (
1.5 times of the Tariff of HT-I(A):General-11
Kwhr 9.45
5 MAT-00692 KVA Category) (as per APEPDCL tariff)

6 MAT-00693 Excise duty on Gates / Hoist supplies % 0

22
Part I-Basic Input data for WR Work items – Common SoR 2021-22

S Rate
Sl DESCRIPTION OF MATERIAL
CFMS CODE UNIT for
No.
2021-22
1 2 3 4 5

7 MAT-00694 Insurance charges on machinery % / annum 1

8 MAT-00695 Interest on capital cost % / annum 9

9 MAT-00696 Lubricants Ltr 255

10 MAT-00697 Petrol Ltr 100.11

11 MAT-00698 Rivets Kg 97

12 MAT-00699 Road tax on transport vehicles Rs./annum As per RTA

13 MAT-00700 Shalimatic sealing compound Kg 94

14 MAT-00701 Shutter oil Ltr 54

15 MAT-00702 Structural steel fabrication Kg 31

16 Sundries ( Lump sum for un quantified inputs ) LS 34


MAT-00703

17 MAT-00704 Water hose ( pressure ) 20 mm dia Rm 178

18 Steel wedges LS 17
MAT-00705

19 MAT-00706 Elbows / Nipple / Plugs etc., LS 17

20 MAT-00707 Soldering materials LS 17

21 MAT-00708 Steam circulation arrangement LS 17

22 MAT-00709 Fuel charges ( gas for heating ) LS 21

23 MAT-00710 Vulcanizing materials LS 21

24 MAT-08527 Other accessories / controls / junctions LS 21

25 Miscellaneous fittings / switches etc LS Deleted

26 Anchors / supports for cables / lights LS Deleted


Civil works for foundations / pedestals / duct Deleted
27 LS
etc

MAT-00711 Gas cutting set ( 2 No’s 15 m hose and nozzle 13,905


28 Each
unit )

29 MAT-00712 Grease Kg 267


Welding holder set ( cable / holder / gloves / 7,844
30 MAT-00713 Each
mask etc )
169
31 MAT-00385 Use rate of ropes LS

23
Part I-Basic Input data for WR Work items – Common SoR 2021-22

MATERIALS FOR GATES AND HOISTS FOR THE YEAR: 2021-22

S Rate for
Sl No. CFMS CODE DESCRIPTION OF MATERIAL UNIT 2021-22

1 2 3 4 5

1 MAT-00095 Worm reducers Each 1,91,493

2 MAT-00096 Electric motor 20 hp(Double Shaft) Each 1,07,929

3 MAT-00097 Electric motor 17.5 hp(Double Shaft) Each 73,345

4 MAT-00098 Electric motor 12.5 hp(Double Shaft) Each 61,986

5 MAT-00099 Electric motor 5 hp(Double Shaft) Each 27,972

6 MAT-00100 Electric motor 3 hp (Double Shaft) Each 19,845

7 MAT-00101 Electric motor 2 hp (Double Shaft) Each 11,028

8 MAT-00102 Floating shaft 300 mm dia Kg 186

9 MAT-00103 Manual operating system Each 28,894

10 MAT-00104 Gate position indicator Each 1,87,312

11 MAT-00105 Ele-magnetic brake Each 30,167

MAT-00106 Electric cable / switch / control panel 48,705


12 LS
etc
13 MAT-00107 Wire rope sockets Each 4,698

24
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

Materials other than covered under WR work items


for the year 2021-22
GENERAL GUIDE LINES FOR REVISING RATES OF MATERIALS:

1. Average of the prevailing market rates, ignoring freak rates, is the criteria for
Fixing market rates for materials.
2. The rates for materials is exclusive of GST, duties and other local levies.
3. The rates for materials are exclusive of Seigniorage charges wherever applicable.
4. The rates for materials, except those for which lead charges are admissible as per the
Statement of lead charges is for all leads.

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5
MAT-
M-002 Quarried stone 150 - 200 mm size for Hand Broken Cum 166
00175
MAT-
M-003 Boulder with minimum size of 300 mm for Pitching Cum 181
00176
Rate as per item no.27
M-004 Coarse sand for filling Cum (b) of Material rates of
WRD.
Rate as per item no.27
M-005 Coarse sand for mortar Cum (a) of Material rates of
WRD.
Rate as per item no.28
M-006 Fine Sand Cum of Material rates of
WRD.
Rate as per item no.56
M-007 Murrum of Material rates of
Cum
WRD.
MAT-
M-008 Gravel/Quarry spall Cum 138
00177
M-009 Granular Material or hard Murrum for GSB works Cum Deleted
MAT-
M-010 Granular Material or hard Murrum for GSB works Cum 100
00178
MAT-
M-011 Fly ash conforming to IS: 3812 ( Part II & I) Cum 75
00179
For item No.M-012 to M-055 the note shall be as follows
1. The rates mentioned are exclusive of Seigniorage
charges but inclusive of blasting charges of
Rs.70/cum and 25% machine crushing charges.
However, if the metal is obtained by hand broken,
machine crushing charges shall be deducted.
2. If the material is obtained by hand broken from
surface boulders/canal spoil, the blasting and
crushing charges shall be deducted.
3. The material shall be HB Stone of Granite,
Dolamite, Dolerite and Trap.(Quartzite and Basalt
with aggregate impact of less than 20)

25
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

Sl. No. CFMS Description Unit S. Rate for


CODE 2021-22
1 2 3 4 5

MAT- Filter media/Filter Material as per Table 300-3 (MoRT&H


M-012 Cum 346
00180 Specification)
MAT- Close graded Granular sub-base Material 53 mm to 9.5
M-013 Cum 674
00181 mm
MAT- Close graded Granular sub-base Material 37.5 mm to 9.5
M-014 Cum 694
00182 mm
MAT- Close graded Granular sub-base Material 26.5 mm to 9.5
M-015 Cum 734
00183 mm
MAT- Close graded Granular sub-base Material 9.5 mm to 4.75
M-016 Cum 608
00184 mm
MAT- Close graded Granular sub-base Material 9.5 mm to 2.36
M-017 Cum 598
00185 mm
MAT- Close graded Granular sub-base Material 4.75mm to 2.36
M-018 Cum 527
00186 mm
MAT- Close graded Granular sub-base Material 4.75mm to 75
M-019 Cum 501
00187 micron mm.
MAT-
M-020 501
00188 Close graded Granular sub-base Material 2.36 mm Cum

MAT- Stone crusher dust finer than 3mm with not more than
M-021 Cum 362
00189 10% passing 0.075 sieve.
MAT-
M-022 517
00191 Coarse graded Granular sub-base Material 2.36 mm & below Cum

MAT- Coarse graded Granular sub-base Material 4.75mm to 75


M-023 Cum 486
00192 micron mm
MAT- Coarse graded Granular sub-base Material 4.75 mm to 2.36
M-024 Cum 486
00193 mm
MAT- Coarse graded Granular sub-base Material 9.5 mm to 4.75
M-025 Cum 593
00194 mm
MAT- Coarse graded Granular sub-base Material 26.5 mm to 4.75
M-026 Cum 648
00195 mm
MAT- Coarse graded Granular sub-base Material 26.5 mm to 9.5
M-027 Cum 649
00196 mm
MAT- Coarse graded Granular sub-base Material 37.5 mm to 9.5
M-028 Cum 719
00197 mm
MAT- Coarse graded Granular sub-base Material 53 mm to 26
M-029 Cum 891
00198 .5mm
MAT-
M-030 582
00199 Aggregates below 5.6 mm Cum
MAT-
M-031 957
00200 Aggregates 22.4 mm to 2.36 mm Cum

26
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5
MAT-
M-032 1,089
00201 Aggregates 22.4 mm to 5.6 mm Cum
MAT-
M-033 694
00202 Aggregates 45 mm to 2.8 mm Cum
Rate as per item no.9 of
M-034 Aggregates 45 mm to 22.4 mm Cum Material rates of WRD.
MAT-
M-035 Aggregates 53 mm to 2.8 mm Cum 957
00203
MAT-
M-036 Aggregates 53 mm to 22.4 mm Cum 907
00204
MAT-
M-037 Aggregates 63 mm to 2.8 mm Cum 745
00205
MAT-
M-038 Aggregates 63 mm to 45 mm Cum 689
00206
Rate as per item no.10
M-039 Aggregates 90 mm to 45 mm of Material rates of
Cum WRD.
Rate as per item no.07
M-040 Aggregates 10 mm to 5 mm of Material rates of
Cum WRD.
MAT-
M-041 Aggregates 11.2 mm to 0.09 mm Cum 745
00207
MAT-
M-042 Aggregates 13.2 mm to 0.09 mm Cum 841
00208
MAT-
M-043 Aggregates 13.2 mm to 5.6 mm Cum 972
00209
MAT-
M-044 Aggregates 13.2 mm to 10 mm Cum 1,084
00210
Rate as per item no.08
M-045 Aggregates 20 mm to 10 mm Cum of Material rates of
WRD.
MAT-
M-046 Aggregates 25 mm to 10 mm Cum 1,190
00211
MAT-
M-047 Aggregates 19 mm to 6 mm Cum 1,094
00212
MAT-
M-048 Aggregates 37.5 mm to 19 mm Cum 1,165
00213
MAT-
M-049 Aggregates 37.5 mm to 25 mm Cum 1,205
00214
MAT-
M-050 Aggregates 6 mm nominal size Cum 790
00215
MAT-
M-051 Aggregates 10 mm nominal size Cum 977
00216
MAT-
M-052 Aggregates 13.2/12.5 mm nominal size Cum 1,145
00217

27
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5
MAT-
M-053 1,418
00218 Aggregates 20 mm nominal size Cum
MAT-
M-054 1,367
00219 Aggregates 25 mm nominal size Cum
MAT-
M-055 881
00220 Aggregates 40 mm nominal size Cum

M-056 AC pipe 100 mm dia Metre Rate as per PH item


MAT-
M-057 Acrylic polymer bonding coat Litre 491
00221
MAT-
M-058 Aluminum Paint Litre 284
00222
MAT-
M-059 Aluminum alloy plate 2mm Thick Sqm 355
00223
MAT-
M-060 Aluminum alloy/Galvanized steel Tonne 62,660
00224
Aluminum sheeting fixed with encapsulated lens
MAT- type reflective sheeting including 2% towards
M-061 Sqm 851
00225 lettering, cost of angle iron, cost of drilling holes,
nuts, bolts etc. and signs as applicable
MAT- Aluminum studs 100 x 100 mm fitted with lens As per local market
M-062 00226 reflectors No’s Rate
MAT-
M-063 74
00227 Barbed wire Kg
MAT-
M-064 512
00228 Bearing (Cost of parts) No’s
MAT- Bearing (Cast steel rocker bearing assembly of 250
M-065 No’s 714
00229 tonne )
Bearing (Elastomeric bearing assembly consisting
MAT- of 7 internal layers of elastomer bonded to 6 nos.
M-066 00230 internal reinforcing steel laminates by the process Cm3
of vulcanization,)
MAT-
M-067 00231 Bearing (Forged steel roller bearing of 250 tonne) No’s

Bearing (Pot type bearing assembly consisting of a


As per Market
metal piston supported by a disc, PTFE pads competitive
MAT- providing sliding surfaces against stainless steel
M-068 00232 mating together with cast steel No’s rates.
assemblies/fabricated structural steel assemblies
duly painted with all components
MAT- Bearing (PTFE sliding plate bearing assembly of 80
M-069 00233 tonnes ) No’s
MAT- Bearing (Supply of sliding plate bearing of 80
M-070 00234 tonne) No’s
MAT-
M-071 8.0
00235 Bentonite Kg

28
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5
Rate as per item
M-072 Binding wire Kg no.3 of Material
rates of WRD.
MAT-
M-073 00236 Bitumen ( Cationic Emulsion ) Tonne
MAT-
M-074 00237 Bitumen (60-70 grade) Tonne
MAT-
M-075 Bitumen (80-100 grade ) Tonne As per rates fixed by
00238
R&B Dept based on
MAT-
M-076 Bitumen (Cutback ) Tonne refinery rates
00239
MAT-
M-077 00240 Bitumen (emulsion) Tonne
MAT-
M-078 00241 Bitumen (modified graded) Tonne

M-079 Brick Each As per Building SSR


MAT-
M-080 58
00242 C.I. shoes for the pile Kg
Rate as per item
M-081 Cement Tonne no.5 of Material
rates of WRD.
Rate as per item
M-082 Cold twisted bars (HYSD/TMT Bars) Tonne no.62 of Material
rates of WRD
MAT-
M-083 Collar for joints 300 mm dia No’s 148
00243
MAT-
M-084 Compressible Fibre Board(20mm thick) Sqm 534
00244
MAT-
M-085 Connectors/ Staples Each 74
00245
MAT-
M-086 Copper Plate(12m long x 250mmwide) Kg 286
00246
Monthly Rate as
MAT-
M-087 fixed by the Sub-
00247 Corrosion resistant Structural steel Tonne
Committee
MAT- Corrugated sheet, 3 mm thick, "Tie" beam section
M-088 Kg 201
00248 railing
MAT-
M-089 222
00249 Credit for excavated rock found suitable for use Cum
Rate as per item
MAT- no.15 of Material
M-090 00250 Curing compound Liter rates of WRD.

Rate as per local


Delineators from ISI certified firm as per the competitive
MAT-
M-091 standard drawing given in IRC – 79 Each quotations
00251

29
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5
MAT- Earth Cost or compensation for selected earth for
M-092 Cum 107
00252 shoulders taken from Private Land
Elastomeric slab seal expansion joint assembly

MAT- manufactured by using chloroprene, elastomer for As per local


M-093 00253 elastomeric slab unit conforming to clause 915.1 of Metre competitive quotations
IRC: 83 (part II),
Rate as per item no.21
Electric Detonators @ 1 detonator for 1/2 gelatin 100 of Material rates of
M-094
stick of 125 gms each no’s WRD.

MAT- Epoxy compound with accessories for preparing 331


M-095 Kg
00254 epoxy mortar
MAT-
M-096 Epoxy mortar Kg 109
00255
MAT-
M-097 Epoxy primer Kg 543
00256
MAT-
M-098 Epoxy resin-hardener mix for prime coat Kg 587
00257
MAT-
M-099 Flag of red color cloth 600 x 600 mm Each 26
00258
MAT-
M-100 Flowering Plants Each 45
00259
MAT-
M-101 Galvanized MS flat clamp No’s 177
00260

MAT- Galvanized steel wire crates of mesh size 100 mm x


M-102 00261 100 mm woven with 4mm dia. GI wire in rolls of Sqm 175
required size.
MAT- Galvanized structural steel plate 200 mm wide, 6
M-103 Kg 894
00263 mm thick, 24 m long
MAT-
M-104 63
00264 Gelatin 80% Kg
Rate as per local
MAT- competitive
M-105 00265 Geo grids Sqm quotations

Rate as per item No.


M-106 (a)Geo membrane 500 micron thick Sqm 52
of WRD
Rate as per item No.
(b) Geo membrane 750 micron thick Sqm 53
of WRD
Rate as per item No.
54
(c) Geo membrane 1000 micron thick Sqm of WRD

30
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5
Rate as per local
competitive
M-107 MAT- Geo nets Sqm quotations
00266
Rate as per item No.
M-108 (a)Geo textile 160 gsm Sqm 29
of WRD
Rate as per item No.
(b) Geo textile 200 gsm Sqm 30
of WRD
Rate as per item No.
(c) Geo textile 250 gsm Sqm 31
of WRD
Rate as per local
MAT- competitive
M-109 00267 Geo textile filter fabric Sqm quotations

MAT-
M-110 21
00268 GI bolt 10 mm Dia No’s
Rate covered in Item
No.36 of hire
charges
M-111 Grouting pump with agitator Hour Of machinery of
Water Resources
work items

MAT-
M-112 7
00269 Grass (Doob) Kg
MAT-
M-113 9
00270 Grass (Fine) Kg

M-114 HDPE pipes 75mm dia Metre


Rate as per PH items
M-115 HDPE pipes 90mm dia Metre
MAT-
M-116 00271 Hedge plants Each
Rate as per local
MAT-
M-117 Helical pipes 600mm diameter Metre competitive
00272
quotations
MAT-
M-118 00273 Hot applied thermoplastic compound Litre
MAT-
M-119 HTS strand Tonne 38,998
00274
MAT-
M-120 Joint Sealant Compound Kg 65
00275

M-121 MAT- Jute netting, open weave, 2.5 cm square opening Sqm 87
00276 for seeding and Mulching

31
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2020-21
1 2 3 4 5
MAT-
M-122 65
00277 LDO for steam curing Litre

M-123 M.S. Clamps Kg Deleted


MAT-
M-124 00278 M.S. Clamps Kg Rate as per local
MAT- market rate
M-125 00279 M.S. shoes @ 35 Kg per pile of 15 m Kg
MAT-
M-126 46,065
00280 Mild Steel bars Tonne

Modular strip/box seal expansion joint including


anchorage catering to a horizontal movement
beyond 70 mm and up to 140mm assembly Rate as per local
MAT- comprising of edge beams, central beam,2 competitive
M-127 00281 modules chloroprene seal, anchorage elements, Metre quotations
support and control system, all steel sections
protected against corrosion and installed by the
manufacturer or his authorized representative
Modular strip/box seal expansion joint catering to
a horizontal movement beyond 140mm and up to
210mm box/box seal joint assembly containing 3 Rate as per local
modules/cells and comprising of edge beams, two competitive
M-128 MAT- central beams, chloroprene seal, anchorage Metre quotations
00282 elements, support and control system, all steel
sections protected against corrosion and installed
by the manufacturer or his authorized
representative
MAT-
M-129 21
00283 Nipples 12mm No’s
MAT-
M-130 102
00284 Nuts and bolts Kg
MAT-
M-131 235
00285 Paint Litre
MAT-
M-132 00286 Pavement Marking Paint Litre
MAT-
M-133 00287 Paving Fabric Sqm
MAT- Rate as per local
M-134 00288 Perforated geo synthetic pipe 150 mm dia Metre competitive
quotations
M-135 MAT- Perforated pipe of cement concrete, internal dia Metre
00290 100 mm
MAT-
M-136 00291 Pesticide Kg

M-137 R.C.C Pipes 200 mm dia, 2.5 m long for drainage Metre Rate as per PH item

32
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5
MAT-
M-138 Plastic sheath, 1.25 mm thick for dowel bars Sqm 53
00292
MAT-
M-139 00293 Plastic tubes 50 cm dia , 1.2 m high No’s Rate as per local
MAT- market rate
M-140 00294 Polymer braids Metre
MAT- Pre moulded Joint filler, 25 mm thick for expansion
M-141 Sqm 296
00295 joint.
MAT-
M-142 00296 Pre-coated stone chips of 13.2 mm nominal size Cum
Preformed continuous chloroprene elastomer or
MAT- closed cell foam sealing element with high tear
M-143 00297 strength, vulcanized in a single operation for the Rate as per local
full length of a joint to ensure water tightness. Metre competitive
MAT- quotations
M-144 00298 Pre-moulded asphalt filler board Sqm
MAT- Pre-packed cement based polymer concrete of
M-145 00299 strength 45 Mpa at 28 days Kg
MAT-
M-146 171
00300 Sealant Primer Kg
MAT-
M-147 32
00301 Quick setting compound Kg
MAT-
M-148 283
00302 Random Rubble Stone Cum

RCC Pipe NP 4 heavy duty non pressure pipe


M-149 Metre
1000 mm dia
RCC Pipe NP 4 heavy duty non pressure pipe Rate as per PH
M-150 Metre items
1200 mm dia
RCC Pipe NP 4 heavy duty non pressure pipe
M-151 Metre
300 mm dia
MAT-
M-152 00303 Reflectorising glass beads Kg
MAT- Reinforcement strips 60 mm wide 5 mm thick as
M-153 00304 per clause 3102. (Copper Strips) Metre

M-154 MAT- Reinforcement strips 60 mm wide 5 mm thick as Metre


00305 per clause 3102. (Galvanized carbon steel strips) Rate as per local
Reinforcement strips 60 mm wide 5 mm thick as competitive
MAT- per clause 3102. (Glass reinforced polymer/ fiber quotations
M-155 00306 reinforced polymer/polymeric strips) Metre
MAT- Reinforcement strips 60 mm wide 5 mm thick as
M-156 00307 per clause 3102. (Stainless steel strips) Metre

M-157 MAT- Reinforcement strips 60 mm wide 5 mm thick as Metre


00308 per clause 3102. (Aluminum strips)

33
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5
MAT-
M-158 7
00309 Rivets Each
Rate as per Item
M-159 Sand bags (Cost of sand and Empty cement bag) Per bag no.2 of
miscellaneous items
Rate as per local
MAT-
M-160 competitive
00310 Sapling 2 m high 25 mm dia Each
quotations
MAT-
M-161 76
00311 Scrap tyres of size 900 x 20 No’s
MAT-
M-162 20
00312 Seeds(Grass) Kg

M-163 Cost of Selected earth Cum Deleted


MAT- Separation Membrane of impermeable plastic
M-164 00313 Sqm Rate as per local
sheeting 125 micron thick
MAT- competitive quotations
M-165 00314 Sheathing duct Metre
MAT-
M-166 Shrubs Each 17
00315
Rate as per local
MAT- Sludge / Farm yard manure @ 0.18 cum per 100
competitive quotations
M-167 00316 sqm at site of work for turfing Cum

M-168 Sodium vapour lamp Each As per Buildings SSR


MAT-
M-169 2,480
00317 Square Rubble Coursed Stone Cum

Steel circular hollow pole of standard specification


MAT- for street lighting to mount light at 5 m height
M-170 00318 Each
Rate Obtained from
above deck level Electricity/Municipal
Departments
MAT- Steel circular hollow pole of standard specification
M-171 00319 forstreet lighting to mount light at 9 m height Each
above road level
MAT- Steel drum 300 mm dia 1.2 m high/empty bitumen
M-172 00320 drum No’s As per local
competitive
MAT- Steel helmet and cushion block on top of pile head market rate
M-173 00321 during driving. Kg
MAT-
M-174 293
00322 Steel pipe 25 mm external dia as per IS:1239 Metre
MAT-
M-175 573
00323 Steel pipe 50 mm external dia as per IS:1239 Metre
MAT-
M-176 193
00324 Steel wire rope 20 mm Kg
MAT-
M-177 215
00325 Steel wire rope 40 mm Kg

34
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5
Rate as per local
MAT-
M-178 competitive
00326 Strip seal expansion joint Metre
quotations
Rate as per item
no.62 of Material
M-179 Structural Steel(HYSD/TMT bars) Tonne rates of
WRD
Rate as per item
Super plasticizer admixture IS marked as per 9103- no.70 of Material
M-180 Kg rates of
1999
WRD
Rate as per local
MAT- Synthetic Geo grids as per clause 3102.8 and
M-181 Sqm competitive
00327 approved design and specifications.
quotations
Rate as per item
Through and bond stone no.75 of Material
M-182 Each rates of
(a) 20X20x30 to 45 cm long
WRD.
Rate as per item
Through and bond stone no.76 of Material
Each rates of
(b) 25X25x45 to 60 cm long
WRD.
Rate as per item
Through and bond stone no.77 of Material
Each rates of
(c) 30X30x65 to 75 cm long
WRD.
MAT-
M-183 53
00328 Tie rods 20mm diameter No’s

M-184 Tiles size 300 x 300 mm and 25 mm thick Each


As per Building SSR
M-185 Timber Cum
MAT-
M-186 00329 Traffic cones with 150 mm reflective sleeve No’s Rate as per local
competitive
MAT- Tube anchorage set complete with bearing plate,
M-187 No’s quotations
00330 permanent wedges etc
MAT-
M-188 Un slaked lime Tonne 2,829
00331

M- MAT- Water charges(Urban) 116


KiloLitre
189(a) 00332
MAT-
(b) 88
00333 Water charges(Rural) KiloLitre

M-190 Water based cement paint Litre As per Building SSR


MAT-
M-191 148
00334 Welded steel wire fabric Kg
MAT-
M-192 259
00335 Wire mesh 50mm x 50mm size of 3mm wire Kg

35
Part I - Materials not covered under WR Work items basic data – Common SoR 2021-22

CFMS S. Rate for


Sl. No. Description Unit
CODE 2021-22
1 2 3 4 5

M-193 Wooden ballies 2" Dia for bracing Each


As per Building SSR
M-194 Wooden ballies 8" Dia and 9 m long Each
MAT-
M-195 1,195
00336 Wooden packing Cum
MAT- Wooden staff for fastening of flag 25 mm dia,
M-196 Each 76
00337 one m long
per cm
MAT-
Item 00338 Printing new letter and figures of any shade (ii) height 2
8.3 English Roman per
letter
Item
Painting Two Coats on New Concrete Surfaces Sqm
8.8
As per Building SSR
Item
Painting angle iron post Two Coats Sqm
8.9
Miscellaneous Items

Benching old embankment slopes


1 MAT- RM 5
00339 0.45 X 0.45 M
Laying Sand Bags in the stipulated places including
cost of empty cement bag, sand, thread,
stiching charges and labour charges with 13.615 %
overhead charges and contractors profits. (sand
rate for filling is considered)
2 34
Note: During the emergency conditions such as
MAT- floods and other natural calamities, the above rate
00340 is allowed to enhance by 25% for 1st warning level per bag
and above, keeping in view of the difficulty in
availability of labour and vehicles.
MAT-
3 166
00341 Rough stone for revetment 225mm thick Cum
MAT- Eradication of Weed growth from Drains, Canals by
4 Sqm 2
00342 spraying Chemicals
MAT-
5 93
00343 Thinner Ltr
MAT-
6 263
00344 Gear Oil Ltr
MAT-
7 107
00345 Cardium compound kg

36
Conveyance Charges of Material – Common SoR 2021-22

Conveyance
Charges of Material

37
Conveyance Charges of Material – Common SoR 2021-22

CONVEYANCE CHARGES OF MATERIALS AS PER SoR 2021-22 (COMMON TO ALL


DEPARTMENTS).

LEAD, LIFT, LOADING AND UNLOADING CHARGES FOR MATERIALS


FOR THE YEAR: 2021-22

1. For total lead up to 150 m (including initial lead) lead charges by head load only shall be
adopted irrespective of mode of conveyance.
2. For total lead exceeding 150 m conveyance by mechanical means only shall be adopted
irrespective of mode of conveyance.
3. The rates for loading at quarry including idle hire charges of trucks and hire charges per
for each kilometer and up to 5 km are cumulative and inclusive of total charges for
Preceding lead.
4. Unless otherwise specified lead charges for Earth / Sand / Gravel / Aggregates and
Stones are for loose volume and not for compacted or in-situ volume.
5. The rates for lift charges, lead charges, hire charges are cumulative and inclusive of rates
for preceding lift, lead and hire charges.
6. Lift charges are not payable where conveyance of materials is by mechanical means to
final placing point.
7. Loading and unloading charges are not payable for conveyance by head load.
8. Loading charges are not payable for conveyance by mechanical means for disposal of
excavated materials beyond initial lead of 50 m wherever specified.
9. Loading and unloading charges are not payable for conveyance by mechanical means
for disposal of excavated materials beyond initial lead of 1 km wherever specified.
10. The rates for unloading of materials except earth, sand, gravel, coarse aggregate, rubble,
size stone and cut stone are inclusive of stacking.
11. Hire charges are per 1KM for tippers and trucks for transport of materials from work site
to dump yard and other places are cumulative& includes previous km up to 5 kms
12. The lead & lift charges are exclusive of contractor's profit and overhead charges of
13.615%
13. The loading and unloading charges are also exclusive of Contractor's profit and
overhead charges of 13.615%
14. During the BoCEs meeting held on 10.06.2015,the BoCEs has recommended to withdraw
lead charges, loading and unloading charges for Cement as per the minutes of meeting
of Sub-Committee held on 29.06.2015.(The conveyance charges ,loading & unloading
charges for cement are displayed for information purpose only).
15. As per the BOCE meeting held on 21.08.2019 in order to simplify the procedure of
adding lead charges to the data items in the CFMS work module, the BOCE
recommended to delete the contractor profit and over head charges from the calculation
of Lead, Lift, Loading and Unloading charges. But at the time of preparation of estimates
the contractor profit and over head charges on Lead, Lift, Loading and Unloading
charges shall be added as usual.

38
Conveyance Charges of Material – Common SoR 2021-22

A. (LEAD) CONVEYANCE CHARGES FOR MATERIALS


BY HEAD LOAD FOR THE YEAR: 2021-22

Earth / Sand /Gravel / Cement / PCC slab/


Total distance Murrum/ Lime/ Surki/ Shahbad slab / CC
Sl Reinforcement
( Total lead includes Size stone block/ BS slab/
No. steel Str steel
initial lead ) / Cut stone Rubble / Late-rite / Wood
Rs / tonne
Coarse aggregate Rs / cum
1 2 3 4 5
Total lead up to 50 m
1 initial lead initial lead initial lead
(covered by item rate)
2 Total lead up to 100 m 70.00 40.80 89.10
3 Total lead up to 150 m 140.00 81.70 178.20
Notes: 1. No loading or unloading charges are admissible for conveyance by head load.
2. For total lead exceeding 150 m conveyance charges by mechanical
means only shall be adopted irrespective of mode of conveyance.
B. (LEAD) CONVEYANCE CHARGES FOR MACHINERY PER KILOMETER FOR
TRANSPORTING MATERIALS BY TIPPERS AND TRUCKS EXCLUDING LOADING,
UNLOADING AND IDLE HIRE CHARGES OF MACHINERY FOR THE YEAR: 2021-22
(No loading and unloading charges allowed for machinery loading and unloading)

(Lead) (Lead) charges


(Lead) charges (Lead)
(Lead) charges for for trucks per
for trucks for charge
charges for trucks for cu.meter for (Lead)
Cement/ Steel/
tippers for Rubble/Size PCC slabs/ charge s for
Sl RCC poles/ AC trucks
Distance Earth / Sand stones/ Cut Shahabad s for
No. /Gravel / & GI sheets/ per
Stones/ slabs/ CC & 1000 1000
Murrum/ Packed litres nos. of
Coarse Laterite
Lime/ Surki/ materials/ blocks/
aggregate bricks
per cu.meter tonne Wood/ cum
per cu.meter
1 2 3 4 5 6 7 8
Lead up
1 33.70 32.50 20.30 47.80 20.60 54.10
to 1 km
Lead up
2 47.20 45.50 28.40 66.90 28.80 75.80
to 2 km
Lead up
3 62.90 60.60 37.90 89.20 38.40 101.10
to 3 km
Lead up
4 76.40 73.60 46.00 108.30 46.60 122.70
to 4 km
Lead up
5 89.90 86.60 54.10 127.40 54.80 144.40
to 5 km
for Every
km
beyond 5 13.50 13.00 8.10 19.10 8.20 21.70
6 km up to
30 km
for Every
km 11.20 10.80 6.80 15.90 6.90 18.10
7 beyond

39
Conveyance Charges of Material – Common SoR 2021-22

C. LOADING AND UNLOADING CHARGES BY MANUAL MEANS


(idle hire charges of trucks are not added)

Rubble/
Earth
size stone/ Brick
/ Sand
Description of /Gravel cut stone/ Cement in Steel in work
Sl No. Coarse
item Murrum/ Rs/tonne Rs./tonne Rs/1000
/ Surki/ aggregate No
Rs / cum , Lime in
Rs/cum
1 2 3 4 5 6 7

1 Loading 23.20 46.50 76.70 91.90 63.90

2 Unloading 11.60 23.25 76.70 91.90 63.90

D. LOADING AND UNLOADING CHARGES BY MANUAL MEANS


(Including idle hire charges of trucks)

Rubble/
Earth / size
Sand stone/ cut brick
Description of /Gravel stone/ cement in steel in work
Sl No. Murrum/ Coarse Rs/tonne Rs./tonne Rs/1000
item
Surki/ aggregate No
Rs / cum
, Lime in
Rs/cum
1 2 3 4 5 6 7

1 Loading 121.70 144.90 184.90 200.20 242.60

2 Unloading 44.30 72.45 184.90 200.20 242.60

E.LOADING AND UNLOADING CHARGES BY MECHANICAL


MEANS
(Including idle hire charges of trucks)
Earth / Sand /Gravel Rubble/ size stone/ cut
Sl No. Description of item Murrum/ Surki/ stone/ Coarse
Rs / cum aggregate, Lime in
Rs/cum
1 2 3 4

1 Loading 54.10 107.60

2 Unloading 17.00 17.00

40
Conveyance Charges of Material – Common SoR 2021-22

F. LIFT CHARGES FOR MATERIALS BY HEAD LOAD

Earth / Sand
PCC
/Gravel Murrum/ Cement /
Total lift (Total Lime/ Surki/ Size slab/ Shahbad
Sl Reinforcement
lift includes stone / Cut stone slab / CC block/
No. steel Str steel
initial lift) Rubble / Coarse BS slab /Laterite
Rs / tonne
aggregate / Wood Rs / cum
Rs / cum
1 2 3 4 5
Total lift up to 3 m
1 (covered by item
Initial lift Initial lift Initial lift
rate)
For Every 1.00 Lift
2 beyond initial lift of 8.20 5.90 10.90
3 meters

41
Machinery Hire Charges – Common SoR 2021-22

HIRE CHARGES

42
Machinery Hire Charges – Common SoR 2021-22

HIRE CHARGES OF PLANT &


MACHINERY FOR THE YEAR: 2021-22
Sl. Hire Fuel Crew Total in
DESCRIPTION UNIT CODE CODE CODE
No Charges Charges Charges Rs
Agitator car /
HIR- HIR- LAB-
1 Transit mixer Hour 668.90 1428.30 365.00 2462.20
00001 00135 00317
2 cum
Air compressor HIR- HIR- LAB-
2 Hour 90.80 285.50 214.50 590.80
5 cmm ( electric ) 00002 00136 00318
Air compressor HIR- HIR- LAB-
3 Hour 204.10 1168.60 274.60 1647.30
7 cmm ( diesel ) 00003 00137 00319
Air compressor HIR- HIR- LAB-
4 Hour 113.40 380.70 214.50 708.60
7 cmm ( electric ) 00004 00138 00320
Air compressor HIR- HIR- LAB-
5 Hour 237.70 1460.70 274.60 1973.00
8.5 cmm ( diesel 00005 00139 00321
Air compressor HIR- HIR- LAB-
6 Hour 145.90 475.90 214.50 836.30
8.5 cmm (Electric) 00006 00140 00322
Air compressor HIR- HIR- LAB-
7 Hour 115.20 1057.50 228.80 1401.50
15 cmm (electric) 00007 00141 00323
Angle Dozer HIR- HIR- LAB-
8 Hour 1531.00 999.10 304.20 2834.30
90 hp 00008 00142 00324
Batching plant HIR- HIR- LAB-
9 Hour 99.50 126.90 439.80 666.20
0.5cum(6 cum/hr) 00009 00143 00325
Batching plant 2
HIR- HIR- LAB-
10 x 1.00 cum(15 Hour 351.80 380.70 439.80 1172.30
00010 00144 00326
cum/hr)
Batching plant 2
HIR- HIR- LAB-
11 x 1.50 cum(50 Hour 538.70 465.30 439.80 1443.80
00011 00145 00327
cum/hr)
Bending machine HIR- HIR- LAB-
12 Hour 38.40 126.90 171.60 336.90
3000 x 12 mm 00012 00146 00328
Clam shell and HIR- HIR-
13 Hour 5.30 0.00 0.00 5.30
hoisting ropes 00013 00147
Concrete bucket HIR- HIR-
14 Hour 14.00 0.00 0.00 14.00
1.5 cum 00014 00148
Concrete hand HIR- HIR-
15 Hour 5.00 0.00 0.00 5.00
mixer 45 / 30 ltr 00015 00149
Concrete mixer
HIR- HIR- LAB-
16 300 / 200 ( Hour 47.30 129.80 286.00 463.10
00016 00150 00329
diesel)
Concrete mixer
HIR- HIR- LAB-
17 300 / 200 ltr Hour 46.20 42.30 286.00 374.50
00017 00151 00330
(electric)
Concrete mixer
HIR- HIR- LAB-
18 600 / 400 ( Hour 80.50 259.70 286.00 626.20
00018 00152 00331
diesel) / 0.28 cum
Concrete mixer
HIR- HIR- LAB-
19 600 / 400 ltr ( Hour 78.90 84.60 286.00 449.50
00019 00153 00332
electric)
Concrete paver HIR- HIR- LAB-
20 Hour 312.30 0.00 549.10 861.40
100 sqm / hr 00020 00154 00333

43
Machinery Hire Charges – Common SoR 2021-22
Sl. Hire Fuel Crew Total in
DESCRIPTION UNIT CODE CODE CODE
No Charges Charges Charges Rs
HIR- HIR- LAB-
21 Convey mucker Hour 722.90 294.40 228.80 1246.10
00021 00155 00334
Core drilling
HIR- HIR- LAB-
22 machine / Drilling Hour 281.90 389.50 365.00 1036.40
00022 00156 00335
equipment
Diesel generating HIR- HIR- LAB-
23 Hour 58.70 1038.70 171.60 1269.00
set 30 KVA 00023 00157 00336
Diesel generating HIR- HIR- LAB-
24 Hour 73.30 1558.10 171.60 1803.00
set 50 KVA 00024 00158 00337
HIR- HIR- LAB-
25 Diesel Loco 45 hp Hour 337.40 876.40 214.50 1428.30
00025 00159 00338
Dewatering pump HIR- HIR- LAB-
26 Hour 9.10 129.80 143.50 282.40
5 hp ( diesel ) 00026 00160 00339
Dewatering pump HIR- HIR- LAB-
27 Hour 2.70 42.30 107.60 152.60
5 hp ( electric ) 00027 00161 00340
Dewatering pump HIR- HIR- LAB-
28 Hour 13.70 259.70 143.50 416.90
10 hp ( diesel ) 00028 00162 00341
Dewatering pump HIR- HIR- LAB-
29 Hour 5.90 84.60 107.60 198.10
10 hp ( electric 00029 00163 00342
Dewatering pump HIR- HIR- LAB-
30 Hour 43.50 519.40 143.50 706.40
20 hp ( diesel ) 00030 00164 00343
Dewatering pump HIR- HIR- LAB-
31 Hour 11.20 169.20 107.60 288.00
20 hp ( electric) 00031 00165 00344
HIR- HIR- LAB-
32 Drifter Hour 283.90 0.00 456.30 740.20
00032 00166 00345
HIR- HIR- LAB-
33 Drilling jumbo Hour 335.30 70.10 228.80 634.20
00033 00167 00346
HIR- HIR- LAB-
34 Dumper 4.5 cum Hour 531.00 654.40 292.00 1477.40
00034 00168 00347
Geophysical
HIR- HIR-
35 Electric resistivity Hour 95.70 0.00 0.00 95.70
00035 00169
meter
HIR- HIR- LAB-
36 Grouting pump Hour 21.10 42.30 343.20 406.60
00036 00170 00348
Guniting / sand HIR- HIR- LAB-
37 Hour 109.30 0.00 286.00 395.30
blast equipment 00037 00171 00349
Ice plant &
HIR- HIR- LAB-
38 accessories 30 t / Hour 163.60 1205.50 171.60 1540.00
00038 00172 00350
day
HIR- HIR- LAB-
39 Jack hammer Hour 17.30 0.00 429.00 446.30
00039 00173 00351
Needle vibrator 40 HIR- HIR- LAB-
40 Hour 6.90 27.50 205.90 240.30
mm ( petrol ) 00040 00174 00352
Needle vibrator 40 HIR- HIR- LAB-
41 Hour 7.20 8.50 205.90 221.60
mm ( electric ) 00041 00175 00353
Needle vibrator 60 HIR- HIR- LAB-
42 Hour 7.20 41.30 205.90 254.40
mm ( petrol ) 00042 00176 00354
Needle vibrator 60 HIR- HIR- LAB-
43 Hour 8.80 12.70 205.90 227.40
mm ( electric ) 00043 00177 00355

44
Machinery Hire Charges – Common SoR 2021-22
Sl. Hire Fuel Crew Total in
DESCRIPTION UNIT CODE CODE CODE
No Charges Charges Charges Rs
Planing machine HIR- HIR- LAB-
44 Hour 111.40 126.90 274.60 512.90
4 m stroke 00044 00178 00356
Plate shearing
HIR- HIR- LAB-
45 machine upto 12 Hour 39.80 169.20 182.50 391.50
00045 00179 00357
mm
Pneumatic placer HIR- HIR- LAB-
46 Hour 153.30 0.00 112.10 265.40
0.5 cum 00046 00180 00358
Pneumatic HIR- HIR- LAB-
47 Hour 18.30 0.00 343.20 361.50
tamper 00047 00181 00359
Pug cutting HIR- HIR-
48 Hour 6.50 4.20 0.00 10.70
machine 00048 00182
HIR- HIR-
49 Pusher leg Hour 11.90 0.00 0.00 11.90
00049 00183
Road roller diesel HIR- HIR- LAB-
50 Hour 179.20 1168.60 278.30 1626.10
10 t 00050 00184 00360
Shovel 0.50 cum HIR- HIR- LAB-
51 Hour 915.70 779.00 304.20 1998.90
75 hp 00051 00185 00361
Shovel 0.85 cum
110 hp / HIR- HIR- LAB-
52 Hour 1529.70 1428.30 304.20 3262.20
Hydraulic 00052 00186 00362
Excavator
Stationery derric HIR- HIR-
53 Hour 75.00 0.00 0.00 75.00
crane 00053 00187
Tipper 5 / 5.5 HIR- HIR- LAB-
54 Hour 404.90 490.80 228.20 1123.90
cum 00054 00188 00363
Tipping tub 1.5 HIR- HIR-
55 Hour 57.90 0.00 0.00 57.90
cum 00055 00189
Tower crane 5 HIR- HIR- LAB-
56 Hour 749.10 220.00 243.40 1212.50
tonne 00056 00190 00364
Transformer 250 HIR- HIR-
57 Hour 5010.10 0.00 0.00 5010.10
KVA 00057 00191
Truck 10 t / Truck
HIR- HIR- LAB-
58 5.5 cum per 10 Hour 366.90 490.80 225.20 1082.90
00058 00192 00365
tonnes
Truck mounted HIR- HIR- LAB-
59 Hour 476.90 490.80 225.20 1192.90
derric crane 5 t 00059 00193 00366
Upright drilling HIR- HIR- LAB-
60 Hour 20.20 42.30 251.60 314.10
machine/Grinder 00060 00194 00367
Ventilation fan 20 HIR- HIR- LAB-
61 Hour 11.30 169.20 37.10 217.60
hp 00061 00195 00368
Vibratory pad HIR- HIR- LAB-
62 Hour 1237.90 1687.90 343.20 3269.00
foot roller 8 t 00062 00196 00369
HIR- HIR- LAB-
63 Wagon drill Hour 169.80 0.00 365.00 534.80
00063 00197 00370
Water tanker HIR- HIR- LAB-
64 Hour 380.50 490.80 225.20 1096.50
8000 ltr 00064 00198 00371
HIR- HIR-
65 Welding set Hour 15.10 101.50 0.00 116.60
00065 00199

45
Machinery Hire Charges – Common SoR 2021-22
Sl. Hire Fuel Crew Total in
DESCRIPTION UNIT CODE CODE CODE
No Charges Charges Charges Rs
Winch 35 hp HIR- HIR- LAB-
66 Hour 123.80 207.30 343.20 674.30
(electric ) 00066 00200 00372
Tractor with 2T HIR- HIR-
67 Hour 345.00 0.00 0.00 345.00
roller 00067 00201
Hydraulic Truck HIR- HIR- LAB-
68 Hour 2915.70 1927.00 685.20 5527.90
Crane 30T 00068 00202 00373
Hydraulic Truck HIR- HIR- LAB-
69 Hour 2071.20 1704.20 685.20 4460.60
Crane 16T 00069 00203 00374
Heavy Duty
Airless Spray HIR- HIR-
70 Hour 112.70 112.70
Painting 00070 00204
Equipment
Concrete Placer
Pump (25 HIR- HIR- LAB-
71 Hour 858.30 507.60 214.50 1580.40
cum/hr) (Electric) 00071 00205 00375
/ 30 Cum

46
Government of Andhra Pradesh

COMMON SCHEDULE OF RATES


FOR THE YEAR 2021-22
(Effective from 1st June, 2021)

R&B Department, AP
ROAD & BRIDGE WORKS

1
INDEX
PART-II
ROAD & BRIDGE WORKS

Sl. No. Description Page No.


From To
1 Preamble 3 8

2 Labour Rates 9 13

3 Material & Work Item Rates 14 25

4 Hire Charges of Plant & Machinery for Road & Bridge Works 26 29

2
PREAMBLE

3
1.0 AREA ALLOWANCES:

A) CORPORATIONS & MUNICIPALITIES:

a) i) 25% extra over the rates on labour component of works is allowed in all
Municipal Corporation Limits of Andhra Pradesh except Greater Visakhapatnam
Municipal Corporation and Vijayawada Municipal Corporation (Upto a belt of 12 kms
from Municipal corporation limits) and other Municipal Corporations as notified by the
Government from time to time.
ii) 40% extra over the rates on labour component of works for Greater Visakhapatnam and
Vijayawada Municipal Corporation limits (Upto a belt of 12 kms from Municipal
corporation limits)
iii) 40% extra over the rates on labour component of works for Amaravati Capital City area
(217.23 Sq. Km) as declared by the Govt. vide GO MS No. 141 MA&UD (M2) Dept.,
dt. 9.6.2015 (This is introduced as per the Govt. instructions issued in Govt. Memo No.
668755/ Reforms/ 2017 dt. 14.7.2017).
b) Allow 20% extra over basic rates on labour component of works in all District
Headquarters and the remaining Municipal limits (up to a belt of 12 Kms. from Municipal
limits)
c) For works at Tirumala Hills in Chittoor District, 40% extra over the basic rates of labour
component is allowed.
d) For works at Horsely hills in Chittoor District, 30% extra over the basic rates of labour
component is allowed.
e) For works located inside Tirumala Temple, 20% extra over the basic rate of labour component
specified for Tirumala Hills is allowed.
f) For Works located inside T.T.D Temples of Sri Padmavathi Ammavari Temple,Tiruchanoor,
Sri Govindaraja Swamy Temple at Tirupathi, Sri Kapileswara Swamy Temple,
Kapilatheertham, Tirupathi and Sri Kalyana Venkateswara Swamy Temple, Srinivasa
Mangapuram , 20% extra over the basic rates of labour component for Tirupathi Municipal
Corporation is allowed.

B) JAIL COMPOUNDS:

20% extra is allowed over labour rates for the works in the Jail compounds. Only equivalent
number of Man Mazdoor shall be provided in the Jail premises and no Women Mazdoor are
allowed inside.

4
C) INDUSTRIAL AREA:

a. 20% Extra over basic rates on labour component works allowed for works situated within 10
Kms belt of Industrial area of Ibrahimpatnam, Vuyyuru, Jaggaiahpeta in Krishna District,
Macherla, Gurajala, Challapalli in Guntur District, Garividi in Vijayanagaram District,
Renigunta in Chittoor District, Yerraguntla & Mangampet in Kadapa District, Hindupur,
Tadipatri, Anantapur, Guntakal, Rayalcheruvu, Yadiki of Anantapur District, Adoni, Dhone,
Cement Nagar, Nandyal, Kurnool, Yemmiganur & Bethamcherla of Kurnool District and
Anakapally of Vishakhapatnam District.

D) AGENCY / TRIBAL AREAS:

a) 25% extra allowed for the works located with in the interior Agency / Tribal limits, i.e.
for the works located with in & upto16 KMs from any all weather route inside Agency /
Tribal.
b) 40% extra allowed for the works located with in the interior Agency / Tribal limits, i.e. for
the works located beyond 16 KMs from any all weather route inside Agency / Tribal.

NOTE: 1. No extra percentage is permissible in respect of Forest produce such as Bamboo, Rellu
grass and for all materials obtained from outside the Agency / Tribal.

2. The extra percentage under Agency / Tribal areas allowance may be allowed on the
labour component and on the labour charges in the rates for conveyance of materials.

3. The extra percentage on cost of materials in Agency / Tribal areas can be allowed on the
labour component only, if they are manufactured in the Agency / Tribal areas itself
except Forest produce.

E) GHAT ROADS:

For Ghat Roads steeper than 1 in 20, the length of the road may be taken as 1.5 times the
existing length of the road for the purpose of leads only for conveyance of materials based on the
certificate for the Ghat Road given by the Superintending Engineer concerned.
Note: Under compelling circumstances, the concerned Chief Engineer can adopt the
equivalent length of road as 2 ½ times of actual length.
Note for area allowances:

If more than one area allowance ( such as those ) for (1) Municipalities (2) Agency /
Tribal areas (3) Industrial areas are applicable for a particular situation, only the maximum out
of the allowable percentages is to be allowed.
5
2.0 WATER LEADS:

The following labour is allowed for conveyance of water for every ½ Kilometer lead or part
there of over the initial lead of ½ kilometer.

a) Cement concrete : 1.5 Women Mazdoor / Cum.

b) Masonry : 1.0 Woman Mazdoor/ Cum.

c) Plastering : 0.5 Woman Mazdoor/ 10 Sq.m

Note:- For Water leads of over 2 KMs, specific approval of Chief Engineer concerned is necessary.

3.0 EXCAVATION OF TRIAL TRENCHES, TRIAL PITS AND EXCAVATION IN


RESTRICTED PLACES: -

I) EXCAVATION OF TRIAL TRENCHES, TRIAL PITS AND EXCAVATION


IN RESTRICTED PLACES: -

A. TRIAL TRENCHES:

1) Trial trenches of not more than 2 metres in width …25% extra

B. TRIAL PITS:

1) Up to 2 Metres depth … 25% extra


2) 2 Metres to 4 Metres depth … 50% extra
3) 4 Metres to 6 Metres depth … 75% extra
4) 6 Metres to 8 Metres depth … 100% extra
5) 8 Metres to 9 Metres depth … 150% extra
6) More than 9 Metres depth … 200% extra

II) EXCAVATION IN RESTRICTED PLACES:-

I) Foundation of Buildings …. 75% extra


II) For pipe lines where the depth is less ..… 75% extra
than 1.5 times the width
III) For pipe lines where the depth is .… 120% extra
1.5 times or more than the width
IV) Silt removal in restricted areas such … 120% extra
U. T’s., Culverts and Syphons.

V) Excavation of field channels … 75% extra

6
VI) For narrow trenches not more than
2 meters in width and depth not less
than twice the width and for excavation … 75% extra
of road boundary drains, model sections
of canals.

VII) High berm cutting of not more than … 50% extra


150 mm average thickness and
Sectioning for roads

Note: 1) The extra percentage is allowed over rate for corresponding soil. It includes the charges
for all lifts and initial lead but does not include dewatering charges if any in respect of all
the items under ( A) and (B) above.

2) The above extra percentages in respect of excavation in hard rock for restricted places
are to be allowed for (2/3) rd of the cost and shall not to be allowed in respect of items
involving blasting component which may be taken as 1/3 of the cost.
4.0 Proportion of First class and 2nd class workmen under Skilled Labour:

30% of the skilled labour provided in the data may be taken as 1st Class and the remaining
70% as 2nd Class.

5.0 Revetment and apron works:

I) The size of stone for the volume range ( 0.015 to 0.030 Cum) shall not be less than
(0.30 X 0.30 X 0.15 to 0.30 X 0. 225 X 0.225m)

II) The size of stone for the volume range (0.011 to 0.015 Cum) shall not be less than
(0.30 X 0.225 X 0.15 to 0.225 X 0.225 X 0. 225 m)

III) The rate of labour component as per the standard data book is to be adopted for
revetment work only. However for apron work Rs. 3.00 per cum. should be
deducted.

IV) For the labour for the “Rock Toe” shall be taken as 2/3rd of the labour charges of
revetment as Chief Engineer, Circular No. P3/ OT2/ T3/ 65167/78, Dt: 19.03.1980.
6.0 Deep cuts:
Deep cuts are defined as reaches of canal where excavation in all soils is for a depth
of excavation 6m and more.The following increase over normal rates is permitted in deep
cuts on a graded basis.

I) Up to 6 m excavation: The S. S. R. of corresponding classification of


earth work excavation is applicable.
II) Beyond 6 m and up to 9 m excavation - 9% extra
III) Beyond 9 m and up to 12 m excavation - 12% extra
IV) Beyond 12 m and up to 16 m excavation - 15% extra

7
V) Beyond 16 m and up to 30 m excavation - 20% extra
VI) Beyond 30 m excavation - 40% extra

NOTE : 1) The extra percentage is only on basic rate. 2) The above percentage are not applicable
for “LEADS & LIFTS”. 3) The above extra percentages are to be allowed only on
items excluding the blasting component which may be taken as 1/3 of the rate.

7.0 The conveyance of bitumen for bulk and packed may be admitted as follows:

Packed --- Rs. 1.75 per Km/ MT


Bulk --- Rs. 1.75 per Km/ MT (round the trip)

8.0 SEIGNIORAGE CHARGES:

Seigniorage charges for materials as fixed by the Government in G.O.Ms.No.11 (Industries


and commerce department) Dt. 11.2.2020 shall be shown in Part-B of the estimate. The
Provision towards Contractor's Profit and Overhead charges should not be operated on the
Seigniorage Charges. In case of revision, the revised rates as fixed by Mines and Geology
Department have to be adopted.

9.0 Earthwork excavation rate for Trench cutting, formation of embankment & shoulders,
foundations, removal of unserviceable soil etc., is to be arrived based on the Machinery
adopted in the MoRTH Standard data book for excavation of soil.

10.0 All the Materials and Machinery Hire charges are excluding taxes.

8
LABOUR RATES

9
Si. S.S. CFMS Code Description Unit S o Rate for Remarks
No Item (Per) 2021-22
No. in Rs.
1 2 3 4 5 6 7
(A) SKILLED WORKMEN
First Class
1 a LAB-00039 Stone cutter Day 580 As per WR Dept.
(S.No.39)
2 b LAB-00011 Mason & Brick Layer Day 585 As per WR Dept.
(S.No.11)
3 c LAB-00004 Carpenter Day 655 As per WR Dept.
(S.No.4)
4 d LAB-00035 Painter Day 655 As per WR Dept.
(S.No.35)
5 e LAB-00036 Plumber Day 655 As per WR Dept.
(S.No.36)
6 f LAB-00041 Welder Day 575 As per WR Dept.
(S.No.41)
7 g LAB-00006 Fitter Day 615 As per WR Dept.
(S.No.6)
8 h LAB-00005 Electrician Day 650 As per WR Dept.
(S.No.5)
9 1 LAB-00125 Cook Day 525 As per WR Dept.
(S.No.2)
Other Category
10 2 LAB-00012 Mechanic Day 590 As per WR Dept.
(S.No.12)
11 3 LAB-00043 Rigger Day 605
12 4 LAB-00044 Rigger Syrang Day 605
13 5 LAB-00045 Well Sinker Day 605
14 6 LAB-00003 Blaster Day 645 As per WR Dept.
(S.No.3)
15 3 LAB-00001 Bar bender Day 700 As per WR Dept.
(S.No.1)
16 7 LAB-00015 Tipper and Heavy Vehicle Driver Day 630 As per WR Dept.
above 12 T (S.No.15)
17 LAB-00046 Tanker and medium Vehicle driver Day 600
(7.5 T to 12 T)
18 LAB-00047 Tanker and Light Vehicle driver up to Day 460
7.5 T
19 LAB-00048 Wagon Drill Operator upto 7.5 T Day 600
20 8 LAB-00049 Lorry and Heavy Vehicle Driver Day 635
above 12 T
21 LAB-00027 Road Roller Driver (7.5 T to 12 T) Day 590 As per WR Dept.
(S.No.27)
22 Road Roller Driver 7.5 T Day Deleted
23 9 Tractor Driver above 12 T Day Deleted
24 Tractor Driver (7.5 T to 12 T) Day deleted
25 LAB-00050 Tractor Driver 7.5 T Day 580
Operator
26 10 LAB-00051 Pan Mixer Day 620
27 LAB-00016 Concrete Mixer Day 575 As per WR Dept.
(S.No.16)

10
Si. S.S. CFMS Code Description Unit S o Rate for Remarks
No Item (Per) 2021-22
No. in Rs.
1 2 3 4 5 6 7
28 LAB-00032 Vibrator Day 575 As per WR Dept.
(S.No.32)
29 LAB-00052 Composer Day 580
30 LAB-00023 Jack Hammer Day 575 As per WR Dept.
(S.No.23)
31 LAB-00034 Driller Day 645 As per WR Dept.
(S.No.34)
32 LAB-00053 Boring Maistry Day 555
33 11 LAB-00024 Pump operator Day 575 As per WR Dept.
(S.No.24)
34 12 LAB-00054 Turner Grade-I Day 605
35 13 LAB-00135 Wireless Operator Day 645 As per WR Dept.
(S.No.12)
Other Category
36 14 LAB-00055 Assistant Wireless Operator Day 550
37 15 LAB-00138 Jeep Driver Day 640 As per WR Dept.
(S.No.15)
Other Category
38 16 LAB-00132 Work Inspector with I.T.I Day 655 As per WR Dept.
qualification (S.No.9)
Other Category
39 17 LAB-00127 Work Inspector with LCE, Day 910 As per WR Dept.
LME,L.E.E qualification (S.No.4)
Other Category
40 18 LAB-00130 Work Inspector with B.E (Civil, Day 1170 As per WR Dept.
Mechanical and Electrical) (S.No.7)
Other Category
qualification
41 19 LAB-00010 Work Inspector with Non-technical Day 640 As per WR Dept.
qualification SSLC/SSC/HSC (S.No.10)

42 20 LAB-00056 Mason Spl. Grade for Mossaic and Day 595


Polished shahabad stone floor
43 21 LAB-00136 Typist / Job Typist Day 645 As per WR Dept.
a(i) (S.No.13)
Other Category
a (ii) LAB-00134 Computer operator Day 715 As per WR Dept.
(S.No.11)
Other Category
b LAB-00137 CAD Operator with Diploma in Day 910 As per WR Dept.
Engineering /General degree with (S.No.14)
Other Category
CAD certificate
(B) SEMI –SKILLED WORKMEN
SECOND CLASS
44 a LAB-00091 Mason Day 525 As per WR Dept.
(S.No.35)
Semi-Skilled
45 b LAB-00091 Brick Layer and Stone Cutter Day 525 As per WR Dept.
(S.No.35)
Semi-Skilled
46 c LAB-00060 Carpenter Day 525 As per WR Dept.
(S.No.4)
Semi-Skilled
47 d LAB-00093 Painter Day 525 As per WR Dept.
(S.No.37)
Semi-Skilled
11
Sl.no S.S. CFMS Code Description Unit S o Rate for Remarks
Item (Per) 2021-22
No. in Rs.
1 2 3 4 5 6 7
48 e deleted
49 f LAB-00002 Blacksmith Day 550 As per WR Dept.
(S.No.2)
(Skilled)
50 g LAB-00098 Welder Day 530
51 h LAB-00099 Fitter Day 530
52 i LAB-00100 Electrician Day 530
53 2 LAB-00101 Caulker Day 530
54 4 LAB-00102 Tinker Day 530
55 5 LAB-00103 Sawyer Day 530
56 6 LAB-00104 Brick-Moulder Day 530
57 7 LAB-00105 Pot-tile turner Day 530
58 8 LAB-00106 Pan-tile turner Day 530
59 9 LAB-00107 Brick and Lime Kiln man/Glazzer Day 530
60 10 LAB-00135 Telephone Operator Day 645 As per WR Dept.
(S.No.12)
Other Category
61 11 LAB-00108 Hand Driller Day 530
62 12 LAB-00109 Quarry Man Day 530
63 13 LAB-00081 Hammer Man Day 525 As per WR Dept.
(S.No.40)
Semi-skilled
64 14 LAB-00110 Thatcher Day 530
65 15 LAB-00111 Fireman Day 530
66 16 LAB-00112 Cleaner/Helper Day 530
67 17 LAB-00113 Stone Packer Day 530
68 18 LAB-00114 Jawali Day 530
69 19 LAB-00115 Ex-Service man/Goorkha watchman Day 530
70 20 LAB-00116 Ratton Worker Day 530
71 21 LAB-00117 Mate Day 530
72 1 LAB-00066 Head Mazdoor (Mukaddar) Day 525 As per WR Dept.
(S.No.10)
Semi-Skilled
(C) UNSKILLED WORKMEN
73 2 LAB-00120 Man Mazdoor Day 490 As per WR Dept.
(S.No.3)
Un-Skilled
74 3 LAB-00122 Watch Man Day 490 As per WR Dept. (S.No.5)
Un-Skilled
75 5 LAB-00121 Woman Mazdoor Day 490 As per WR Dept.
(S.No.4)
Un-Skilled
76 6 (b) LAB-00123 Helper/Cleaners/Sweepers/Scavangers/Ch Day 470
oukidars/Security Guards/Office Boys
77 Note : Whenever unskilled workmen are engaged for cleaning of
Sewers & Septic Tanks, they may be paid double the above wages.

12
(D) OTHER CONVEYANCE ITEMS
Sl.no S.S. CFMS Code Description Unit S o Rate for Remarks
Item (Per) 2021-22
No. in Rs.
1 2 3 4 5 6 7
78 1 LAB-00062 Single bullock with driver and cart Day 550 As per WR Dept.
(S.No.6)
Semi-Skilled
79 2 Bullock pair with driver Day 605
80 3 LAB-00061 Bullock pair with driver and cart Day 585 As per WR Dept.
(S.No.5 )
Semi Skilled
81 4 LAB-00140 Bullock pair with driver and cart with Day 675
pneumatic tyres
82 5 Bullock pair driver and kapila Day Deleted
83 6 LAB-00063 Nava with crew Day 525 As per WR Dept.
(S.No.3)
Semi Skilled
84 7 LAB-00141 Punt thundal Day 450
85 8 LAB-00142 Punt lascar Day 450
Note: 1) The wage should not be less than the minimum wages of schedule of employment,
subject to out turn.

2) 25% extra over the corresponding labour rates in respect of the work to be done
during night time subject to issue of certificate accordingly by the concerned estimate
sanctioning authority for providing in the data and by the concerned Executive Engineer
in charge of the work for payment. The night time allowance is applicable only to the
works done under Greater Visakhapatnam Municipal Corporation and Vijayawada
Municipal Corporation only.

13
MATERIAL & WORK ITEM
RATES

14
RATES OF MATERIALS & WORK ITEMS

S.S. S o Rate Remarks


Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
(A) STONE AND ROAD MATERIALS
ROUGH STONE QUARRIED
INCLUDING WEDGING, BREAKING,
BURNING, SPLITTING.
1 MAT-00405 22.a For R.R Masonry Work (other than 1 cum 171.45
Granite, Dolomite and Trap)
2 MAT-00341 b.i For SS Revetment work 225 mm 1 cum 166.00 As per WR Dept.
(S.No.3) of
Miscellaneous
items

3 MAT-00176 b.ii For SS Revetment work 300 mm 1 cum 181.00 As per WR Dept.
(M 003 of
Materials other
than covered
under Irrigation
items)
4 MAT-00406 b.iii For SS Revetment work 450 mm 1 cum 148.55
5 MAT-00407 c Jeddy Stone above 450 mm to 600 mm 1 cum 196.20
6 MAT-00408 d i Laterite for revetment 225 mm 1 cum 129.50
7 MAT-00409 d ii Laterite for revetment 300 mm 1 cum 151.43
8 MAT-00410 d iii Granite for SS revetment 225 mm 1 cum 168.55
9 MAT-00411 d iv Granite for SS revetment 300 mm 1 cum 163.80
Note:- Only when other granite is not
available
10 MAT-00412 e Laterite for masonry 1 cum 148.55
11 MAT-00413 f Cyclopean stones above 0.2 cum 1 cum 278.10
12 MAT-00302 g For R.R.Masonry works ( granite, dolamite 1 cum 283.00 As per WR Dept.
and trap variety) (M 148 of
Materials other
than covered
under Irrigation
items)
13 NOTE:- For items 22(a) to 22© and 22(g) 1 cum 70.00
add extra Rs /cum, wherever quarrying
is done by blasting
COURSED RUBBLE STONE
QUARRYING WEDGING,
BREAKING, BURNING AND
SPLITTING FOR SS FIRST SORT
WORKS
14 MAT-00414 23.a Granite, Dolamite and trap 1 cum 274.30
15 MAT-00415 23.b For other varieties 1 cum 197.15
16 MAT-00416 27 Granite stone slabs for culverts, lintels and 1 cum 1810.50
copings (3 faces dressed coarsed rubble
masonry)

15
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7

17 NOTE: - For items 23(a), 23(b) and 27 add 1 cum 82.00


extra Rs. Per Cum, wherever quarrying is
done by blasting

18 MAT-00417 28.a Bond stones ( 600 x 200 x 200 mm ) each 47.60

19 MAT-00418 b Chainage stones and Centre line stones each 47.60


(750x150x150 mm)
20 MAT-00419 31 Demarcation Stones ( 900 x 150 x 150 mm) each 85.70
21 MAT-00420 32.a Guard Stones ( 1200 x 200 x 200 mm ) each 144.75
22 MAT-00421 B Guide Stones ( 800 x 150 x150 mm ) each 97.15
23 MAT-00422 C Carving letters and figures in stone up to each 9.50
100 mm size
24 MAT-00423 D Carving letters and figures in stone above each 10.50
100 mm size
HARD BROKEN STONE OF
GRANITE, TRAP AND DOLERITE
FREE FROM DUST OBTAINED BY
QUARRYING, WEDGING,
BREAKING, BURNING AND
SPLITTING
25 MAT-00215 33.a - do - 6mm size (SS 5) 1 cum 576.00 As per WR Dept.
(M 050 of
Materials
excluding
blasting charges
Rs.70/- and
Machine crushing
charges @ 25%)

26 MAT-00216 b - do - 10mm size (SS 5) 1 cum 726.00 As per WR Dept.


(M 051 of
Materials
excluding
blasting charges
Rs.70/- and
Machine crushing
charges @ 25%)

16
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
27 MAT-00217 c - do - 12mm size (SS 5) 1 cum 860.00 As per WR Dept.
(M 052 of
Materials
excluding
blasting charges
Rs.70/- and
Machine crushing
charges @ 25%)

28 MAT-00218 d - do - 20mm size (SS 5) 1 cum 1079.00 As per WR Dept.


(M 053 of
Materials
excluding
blasting charges
Rs.70/- and
Machine crushing
charges @ 25%)

29 MAT-00219 e - do - 25mm size (SS 5) 1 cum 1038.00 As per WR Dept.


(M 054 of
Materials
excluding
blasting charges
Rs.70/- and
Machine crushing
charges @ 25%)

30 MAT-00220 f - do - 40mm size (SS 5) 1 cum 649.00 As per WR Dept.


(M 055 of
Materials
excluding
blasting charges
Rs.70/- and
Machine crushing
charges @ 25%)

31 MAT-00424 g - do - 50mm size (SS 5) 1 cum 434.30

32 MAT-00425 h - do - 60mm size (SS 5) 1 cum 399.05

33 MAT-00426 i - do - 65mm size (SS 5) 1 cum 360.95

34 MAT-00427 j - do - 75mm size (SS 5) 1 cum 289.50

35 MAT-00428 k - do - 75 to 100mm size (SS 5) 1 cum 236.20

36 NOTE:- (1) Add extra Rs. /- per cum for 1 cum 70.00
items 33 (a) to 33 (k) if the metal is
obtained by blasting
37 (2) Add 25% extra per cum if the metal is 1 cum 25%
obtained by machine crushing excluding
cost of blasting.

17
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
38 (3) Deduct Rs. /- per cum if the metal or 1 cum 9.90
rubble is obtained from surface stone and
boulders.
39 (4) Add Rs. /- per cum for selection of 1 cum 17.00
stones and boulders from excavated spoil
dumps for items 33 a to 33 k, when this
addition of Rs. /- per Cum is allowed,
1 cum 9.90
deduction of Rs. /- per Cum mentioned
under Note (3) above should invariably be
made.
SOFT BROKEN STONE SCREENED
AND FREE FROM DUST
40 MAT-00429 33.l - do - 40 mm size ( SS 5 ) 1 Cum 117.15
41 MAT-00430 33.m - do - 50 mm size ( SS 5 ) 1 Cum 105.70
42 MAT-00431 33.n - do - 60 mm size ( SS 5 ) 1 Cum 82.85
43 MAT-00432 33.o - do - 65 mm size ( SS 5 ) 1 Cum 74.30
44 MAT-00433 33.p - do - 75 mm size ( SS 5 ) 1 Cum 69.50
HARD BROKEN STONE OF
GRANITE TRAP DOLERITE AND
DOLAMITE FREE FROM DUST
OBTAINED BY QUARRYING
WEDGING, BREAKING, BURNING
AND SPLITTING (QUARTZITE AND
BASALT WITH AGGREGATE
IMPACT OF LESS THAN 20)
45 MAT-00434 33a -do- 2.36 to 5 mm size (IRC&MORTH) 1 cum 381.00
46 MAT-00435 b -do- 5 to 7mm size (IRC&MORTH) 1 cum 524.20
47 MAT-00436 c -do- 9.5 to 11.2mm size (IRC&MORTH) 1 cum 682.20
48 MAT-00437 d -do- 12mm to 14 mm size ( IRC and 1 cum 772.60
MORTH )
49 MAT-00438 e -do- 19 mm to 22 mm size ( IRC and 1 cum 984.00
MORTH )
50 MAT-00439 f -do- 25 mm to 27 mm size ( IRC and 1 cum 944.00
MORTH )
51 MAT-00440 g -do- 40 mm to 45 mm size ( IRC and 1 cum 604.80
MORTH )
52 MAT-00441 h -do- 50 mm to 55 mm size ( IRC and 1 cum 492.50
MORTH )
53 MAT-00442 i -do- 60 mm to 63 mm size ( IRC and 1 cum 452.50
MORTH )
54 MAT-00443 j -do- 65 mm size ( IRC and MORTH ) 1 cum 360.95
55 MAT-00444 k -do- 75 mm size ( IRC and MORTH ) 1 cum 289.50
56 l NOTE:- Add extra Rs. /- per cum for 1 cum 70.00 As proposed by
items 33 (a) to 33 (j) if the metal is WR Dept.
obtained by blasting

18
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
57 2 Add 25% extra per cum if the metal is 1 cum 25% As proposed by
obtained by machine crushing excluding WR Dept.
cost of blasting.
58 3 Deduct Rs. /- per cum if the metal or 1 cum 9.90
rubble is obtained from surface stones and
boulders
59 4 Add Rs. /- per cum for selection of stones 1 cum 17.00
and boulders from excavated soil dumps for
items 33 (a) to 33 (k), when this addition of
Rs. /- per cum allowed deduction of Rs.
/- per cum mentioned under note (3) above 9.90
should invariably be made
HARD BROKEN STONE OTHER
THAN GRANITE SUCH AS QUARTZ,
QUARTZ-NAPA AND BASALT
SCREENED AND FREE FROM DUST
60 MAT-00445 33.q - do - 10 mm size (SS 5) 1 Cum 367.60
61 MAT-00446 -do- 9.5 mm to 11.2 mm size ( IRC and 1 Cum 367.60
MORTH )
62 MAT-00447 r - do - 12 mm size (SS 5) 1 Cum 344.75
63 MAT-00448 -do- 12mm to 14 mm size ( IRC and 1 Cum 344.75
MORTH )
64 MAT-00449 S - do - 20 mm size (SS 5) 1 Cum 279.05
65 MAT-00450 -do- 19 mm to 22 mm size ( IRC and 1 Cum 279.05
MORTH )
66 MAT-00451 T - do - 25 mm size (SS 5) 1 Cum 273.35
67 MAT-00452 U - do - 40 mm size (SS 5) 1 Cum 161.90
68 MAT-00453 -do- 40 mm to 45 mm size ( IRC and 1 Cum 161.90
MORTH )
69 MAT-00454 V - do - 50 mm size (SS 5) 1 Cum 142.85
70 MAT-00455 -do- 50 mm to 55 mm size ( IRC and 1 Cum 142.85
MORTH )
71 MAT-00456 33.w - do - 65 mm size (SS 5) 1 Cum 135.25
72 MAT-00457 -do- 60 mm to 65 mm size ( IRC and 1 Cum 135.25
MORTH )
73 MAT-00458 X - do - 75 mm size (SS 5) 1 Cum 111.45
74 MAT-00459 - do - 75 mm size ( IRC &MORTH) 1 Cum 111.45
75 MAT-00460 Y - do - 75 to 100 mm size (SS 5) 1 Cum 87.60
76 MAT-00461 - do - 75 to 100 mm ( IRC& MORTH) 1 Cum 87.60
OTHER ITEMS
77 MAT-00462 33.z1 Laterite 40 to 75 mm ( ring) 1 Cum 96.20
78 MAT-00463 z2 kankar, hard broken kankar 40 to 75 mm ( ring ) 1 Cum 71.45
79 MAT-00464 z3 Soling stone of 150 mm size of granite, trap 1 Cum 90.50
and Dolamite varieties.

19
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
80 NOTE:- (1) Add extra for items to 33(z3) 1 Cum 70.00 As proposed by
Rs /- Per cum, wherever quarrying is done WR Dept.
by blasting. (2) Wherever controlled
blasting is resorted to the Chief Engineer
concerned shall approve the observed data
in support of SS item No. 22 a to 22 c , 22g,
23
81 MAT-00465 z4 Soling stone of 150 mm size other than 1 Cum 72.40
granite variety
82 MAT-00466 z5 Soling Stone laterite, Kankar 150mm, 1 Cum 44.75
surface stone
83 MAT-00467 z6 Field picked metal unbroken 20 mm size 1 Cum 58.10
84 MAT-00468 z7 - do - 25 mm size 1 Cum 43.80
85 MAT-00469 z8 - do - 40 mm size 1 Cum 50.50
86 MAT-00470 z9 - do - 50 mm size 1 Cum 43.80
87 MAT-00471 z10 - do - 60 mm size 1 Cum 38.10
88 MAT-00472 z11 - do - 80 mm size 1 Cum 33.35
89 NOTE:- Add Rs. /- Per Cum for selection of stone and 17.00
boulders from excavated spoil dumps for items 33 (Q) TO
33 Z , when this addition of Rs. /- per Cum is allowed,
deduction of Rs. /- per Cum should invariably be made
towards the metal or rubble if it is obtained from surface
stone and boulders.
90 MAT-05253 34 Gravel 1 Cum 138.00 As per WR Dept.
(M 008 of
Materials other
than covered
under Irrigation
Items )
91 MAT-00473 35 a Quarry rubbish 1 Cum 84.75
92 MAT-00068 B HBG Stone Chips 2.36 mm and below 1 Cum 385.00 As per WR Dept.
(Sl.No.67 of
Materials)
93 MAT-00027 36.a Fine aggregate / Sand (un-screened) for 1 Cum 605.00 As per WR Dept.
Concrete & Filtering items (Si. No. 27 of
Materials) and
will be revised as
94 MAT-00028 b. Fine aggregate / Sand (unscreened) for 1 cum 460.00 per the Govt. new
filling sand policy

95 MAT-00029 c Fine aggregate / Sand (screened) for 1 Cum 700.00 As per WR Dept.
Mortar, Plastering items and Sand blasting (Si. No. 28 of
Materials) and
items (Rs. 95/- is added towards will be revised as
screening charges) per the Govt. new
sand policy

96 MAT-00475 37 Clay for puddle and masonry Items 38 (a) 1 Cum 38.00
to 39 (h) As per local prevailing rates based
on competitive quotations.

20
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
(C) LIME AND CEMENT
97 40 to As per local
41(c ) prevailing
rates based on
competitive
rates
98 MAT-00005 42 Cement excluding cost of empty cement 1 MT 3680/- Monthly rates
bags will be
communicated
by the Govt
NOTE: (1) The rates are exclusive of VAT, Excise duty and GST 2) The price
of cement will be reviewed and fixed on monthly basis and rates will be
communicated separately.

99 MAT-00476 C Grinding lime mortar or Surkhi mortar 1 Cum 95.25


100 MAT-00477 D Shell lime slaked and screened 1 Cum 940.00
101 MAT-00478 E White cement 1 Kg. 27.95
102 (D) MORTARS
103 43 to Items 43 to 45
45
(E) METAL AND IRON WORKS
104 Mild steel rods 6mm dia. 1 MT Monthly rates
communicated
105 Mild steel flats 1 MT
by the Govt
106 Mild Steel, Structural Steel, I.e., Angles, 1 MT
Channels and I sections.
107 High Yield Strength Deformed Bars/TMT 1 MT
bars
108 Mild steel plates 1 MT
NOTE: (1) The rates are exclusive of VAT, Excise duty and
GST 2) The prices of steel will be reviewed and fixed on
monthly basis and rates will be communicated separately.

III RATES OF WORKS


(A) CLEARING SITE
109 MAT-00479 1.a Clearing heavy Jungle 1 Sqm 3.20
110 MAT-00480 b Clearing light Jungle 1 Sqm 2.80
111 MAT-00481 c Clearing Scrub Jungle 1 Sqm 2.80
112 MAT-00482 d Clearing Juliflora (Prosafis) jungle 1 Sqm 4.40
including up-rooting and removing of
Juliflora stumps.
113 MAT-00483 2.a.1 Cutting and removing Palmyrah trees Each 21.00
including stacking of girth 30 to 100 cm.
114 MAT-00484 a.2 - do - 100 to 200 cm. Each 48.00
115 MAT-00485 2.b.1 Uprooting and removing Palmyrah stumps Each 51.00
including stacking of girth 30 to 100 cm.
21
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
116 MAT-00486 b.2 - do - 100 to 200 cm. Each 53.00
117 MAT-00487 2.c.1 Cutting and removing date trees including Each 26.00
stacking of girth 30 to 100 cm
118 MAT-00488 c.2 - do - 100 to 200 cm Each 39.00
119 MAT-00489 2.d.1 Uprooting and removing stumps of date Each 26.00
trees including stacking of girth 30 to 100
cm.
120 MAT-00490 d.2 - do - 100 to 200 cm Each 33.00
121 MAT-00491 2.e 1 Cutting and removing other kind of trees Each 33.00
including stacking of girth 30 to 100 cm
122 MAT-00492 e.2 - do - 100 to 200 cm Each 51.00
123 MAT-00493 e.3 - do - above 200 cm Each 83.00
124 MAT-00494 2.f.1 Uprooting and removing stumps of other Each 26.00
kind of trees including stacking of girth 30
to 100 cm.
125 MAT-00495 f.2 - do - 100 to 200 cm Each 36.00
126 MAT-00496 f.3 - do - above 200 cm Each 45.00
127 MAT-00497 3.a Uprooting and clearing prickly pear jungle 1 Sqm 2.50
128 MAT-00498 b - do - under 2.5 meters height including 1 Sqm 3.30
burning and burrying as directed.
129 MAT-00499 c - do - over 2.5 meters height including 1 Sqm 3.90
burning and burrying with an initital lead of
conveyance
130 MAT-00500 4.a Removing of natchu, goobi, thooti etc., 1 Sqm 2.10
from drains, channels including clearance if
not more than 1 metre depth of water with
an initial lead of 10 metresand lift of 2
metres.
131 MAT-00501 b.i Clearing alchi, tilla 1 Sq.m 4.20
132 MAT-00502 b.ii Removal of Jammu 1 Sq.m 3.60
133 MAT-00503 c.i Removal of imponea, cornea 1 Sq.m 4.00
134 MAT-00504 c.ii Removal of water hyacinth upto 30 cm 1 Sqm 4.10
thick.
135 MAT-00505 c.iii - do - more than 30 cm thick 1 Sq.m 5.50
136 MAT-00506 d Removal of natchu, goobi, thooti etc., for 1 Sqm 1.50
every extra lead or lift over the initial lead
or lift.

(B) DISMANTLING
DISMANTLING, CLEARING AWAY
5 MATERIALS USEFUL FOR REUSE.

137 MAT-00507 a.i Dry rough stone revetment for aprons and 1 cum 65.60
stacking within 40 metres
7 Drilling holes in hard granite or sheet
rock
22
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
a) Manually ( Hand)
138 MAT-00508 i) 20 mm dia meter 1 RM 136.00
139 MAT-00509 ii) 25 mm dia meter 1 RM 144.00
140 MAT-00510 iii) 36 mm dia meter 1 RM 166.00
141 b) Pneumatic Compressor
142 MAT-00511 i) 20 mm dia meter 1 RM 154.00
143 MAT-00512 ii) 25 mm dia meter 1 RM 167.00
144 MAT-00513 iii) 36 mm dia meter 1 RM 182.00
8 Grouting the holes with neat cement
slurry excluding cost of steel

145 MAT-00514 i) 20 mm dia meter 1 RM 97.00


146 MAT-00515 ii) 25 mm dia meter 1 RM 122.00
147 MAT-00516 iii) 36 mm dia meter 1 RM 152.00
White Washing and Painting works
148 MAT-00517 A White washing and colour banding for each 10.00
guard and guide stones including cost of
materials

149 MAT-00518 B1 Screening sand and gravel 1 cum 10.50

150 MAT-00519 B2 Screening chips and metal 1 cum 17.60

151 MAT-00520 C Removing and refixing Hectometre or each 12.65


Demarcation stones

(S ) ROAD WORK ITEMS


PICKING OLD METALLED SURFACE
TO DEPTH OF 40 TO 100 mm
SPREADING OLD METAL AND NEW
METAL SECTIONING INCLUDING
EDGEBUNDS AND SUBGRADE
ROLLING, SPREADING METAL
INCLUDING BLINDAGE OFGRAVEL
WATERING WITH AN INITIAL LEAD
OF 2 HECTOMETERS AND HAND
ROLLER ( 1.5 TO 2 TONNES)
ROLLING ETC., INCLUDING
BARRICADING, DIVERSION OF
TRAFFIC AND WETTING THE NEW
CONSOLIDATION FOR A
FORTNIGHT COMPLETE

( For a compact thickness )


1 (i ) HARD METAL

23
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
152 MAT-00521 A 40 mm thickness 10 sqm 70.00
153 MAT-00522 B 50 mm thickness 10 sqm 74.00
154 MAT-00523 C 75 mm thickness 10 sqm 80.30
155 MAT-00524 D 100 mm thickness 10 sqm 87.00
156 1 (ii ) (For compact thickness of soft metal)
157 MAT-00525 A 50 mm thickness 10 sqm 53.80
158 MAT-00526 B 75 mm thickness 10 sqm 63.90
159 MAT-00527 C 100 mm thickness 10 sqm 70.10
5 Picking old metalled surface to a depth of
40 to 100 mm and spreading metal
including watering with an initial lead of
2 Hectometers and rolling with power
rollers watering and spreading gravel for
blindage and power roller rolling
including hire charges of power roller( 8
to 10 T ) barricading and diversion of
traffic and wetting the new consolidation
for a fortnight(for compacted thickness of
)
HARD METAL
160 MAT-00528 5 (a) 40 mm thick ness 10 sqm 185.00
161 MAT-00529 (b) 50 mm thick ness 10 sqm 210.00
162 MAT-00530 (c ) 75 mm thick ness 10 sqm 231.00
163 MAT-00531 (d ) 100 mm thick ness 10 sqm 248.80
164 MAT-00532 (e) 150 mm thick excluding hire charges 10 sqm 445.40
165 MAT-05455 Gelatin(For MORTH data, for works of Per Kg 63.00 As per WR Dept.
state & national high ways only) (M 104 of
Materials other
than covered
under Irrigation
Items)
166 MAT-00021 Electric Detonators(For MORTH data, for each 10.00 As per WR Dept.
works of state & national high ways only) (Si. No. 21 of
Materials of WR
Dept.)

167 MAT-00273 Hot applied thermoplastic compound(For Per litre Rate as per As per WR Dept.
MORTH data, for works of State & local (M 118 of
Materials other
National high ways only) competitive than covered
quotations under Irrigation
Items)
168 Reflectionising glass beads of 2 mm Per Kg deleted
thick(For MORTH data, for works of State
& National high ways only)
169 MAT-00533 Road marking paint confirming to IS Per Kg 152.15
164(For MORTH data, for works of State &

24
S.S. S o Rate Remarks
Si. Unit
CFMS Code Item Description for 2021-22
No (per)
No. in Rs.
1 2 3 4 5 6 7
National high ways only)

170 n Labour charges for laying filters with coarse 1 cum 55.30
aggregate.
171 o Labour charges for laying filter with sand. 1 cum 30.70
172 Fly Ash 1 cum deleted

173 MAT-00003 Binding Wire 1 Kg 64.00 As per WR Dept.


(M 072 of
Materials other
than covered
under Irrigation
Items)

174 MAT-00536 Jute rope Mtr 8.35


175 MAT-00537 De bonding strips Mtr 8.55
176 MAT-00538 Selent Ltr 53.95
177 MAT-00539 Poly sheet 125 microns 1 sqm 15.25
178 MAT-00540 Rural water rate 1 kl 88.00 As per WR Dept.
(M 189-b of
Materials other
than covered
under Irrigation
Items)

25
HIRE CHARGES OF PLANT
AND MACHINERY

26
HIRE CHARGES OF PLANT& MACHNIERY FOR
ROAD & BRIDGE WORKS FOR THE YEAR 2021-22

CFMS S o Rate for Remarks


Sl. Code Description 2021-22
Unit in Rs.
No.
Machine Activity
1 2 3 4 5 6 7
1 HIR-00008 Dozer( D 80 ) Spreading Per 2834.30
Hour As per WR
Cutting
Dept. (S.No.8)
Cleaning
2 HIR-00072 Dozer (D50) Spreading 1733.10
Per
Cutting
hour
Cleaning
3 HIR-00073 Mortor Grader Clearing 3383.50
Spreading
Per
GSB Hour
WMM
4 HIR-00052 Hydraulic Soil Ordinary 3262.20 As per WR
Excavator Soil Marshy Per
Dept. (S.No.52)
Hour
Soil unsuitable
5 HIR-00074 Front end loader Soil loading Per 1803.00
Hour
Aggregate loading Per
Hour
6 HIR-00052 Tipper- 5.5 Cum Transportation of Per 1123.90 As per WR
soil, GSB,WMM, Hour Dept. (S.No.54)
Hot mix etc

7 HIR--00062 Vibratory roller 8 Earth/Soil, GSB, Per 3269.00 As per WR


tonne WMM Hour Dept. (S.No.62)

8 HIR-00075 Smooth wheeled Soil compaction Per 1626.10 As per WR


roller 8 tonne ,BM compaction Hour dept. (S.No.50)

9 HIR-00064 Water tanker 8 Water transport Per 1097.50 As per WR


Kilolitre Hour Dept. (S.No.64)

10 HIR-00076 Water tanker 6 Water transport Per 732.50


Kilolitre Hour
11 HIR-00077 Tractor Pulling Per 472.80
Hour
12 HIR-00078 Tractor with GSB mixing @ site Per 483.40
rotavator Hour
13 HIR-00079 Tractor with ripper Scarifying Per 483.40
attachment Hour
14 HIR-00002 Air Compressor 5 General purpose Per 590.80 As per WR
cmm(electric) Hour Dept. (S.No.2)
15 HIR-00080 Wet mix plant 60 Wet mix Per 1851.80
TPH Hour
16 HIR-00081 Mechanical broom Surface cleaning Per 404.70
Hydraulic Hour
17 HIR-00082 Bitumen Pressure Applying bitumen Per 1699.20
Distributor tack coat Hour

27
CFMS S o Rate for Remarks
Sl. Code Description 2021-22
Unit in Rs.
No.
Machine Activity
1 2 3 4 5 6 7
18 HIR-00083 Emulsion Pressure Applying emulsion Per 974.10
Distributor tack coat Hour
19 HIR-00084 Hot mix Plant – DBM/BM/SDC Per 31951.60
120 TPH capacity /Premix Hour
20 HIR-00085 Hot mix Plant – DBM/BM/SDC Per 27420.10
100 TPH capacity /Premix Hour
21 HIR-00086 Hot mix Plant – 60 DBM/BM/SDC Per 24588.80
TPH capacity /Premix Hour
22 HIR-00087 Hot mix Plant – 40 DBM/BM/SDC Per 21754.40
to 60 TPH capacity /Premix Hour
23 HIR-00088 Paver Finisher DBM/BM/SDC Per 3467.30
Hydrostatic with /Premix Hour
sensor control 100
TPH
24 HIR-00089 Paver finisher Paving of WMM, Per 2549.30
Mechanical 100 paving of DLC Hour
25 HIR-00090 Hydraulic Chip Surface dressing Per 2908.30
Spreader Hour
26 HIR-00091 Tandem Road roller Rolling of Asphaltic Per 1967.90
surface Hour
27 HIR-00092 Pneumatic Road Rolling of Asphaltic Per 1606.50
roller surface Hour
28 HIR-00093 Pot-Hole repair Repair of pot-holes Per 957.20
machine Hour
29 HIR-00094 Bitumen boiler oil Bitumen Spraying Per 236.40
fired Hour
30 HIR-00095 GSB Plant 50 Cum Producing GSB Per 1356.50
Hour
31 HIR-00096 Mastic Cooker Mastic wearing coat Per 84.30
Hour
32 HIR-00097 Batching and Concrete mixing Per 1416.20
Mixing Plant Hour
(a) 30 Cum
capacity
HIR-00010 (b) 15 - 20 Cum Concrete mixing Per 1172.30 As per WR
capacity Hour Dept. (S.No.10)

33 HIR-00001 Transit mixer Transportation of Per 2462.20 As per WR


concrete mix Hour Dept. (S.No.1)
34 HIR-00071 Concrete pump of Pumping of Per 1580.40 As per WR
45 and 30 cum Concrete Hour Dept. (S.No.70)
35 HIR-00098 Cranes
(a) 80 tonnes Lifting purpose Per 1389.90
HIR-00099 (b) 35 tonnes Hour 938.80
HIR-00100 (c) 3 tonnes 455.40
HIR-00101 (d)Crane with grab Well foundation Per 2447.40
bucket 0.75 cum Hour
HIR-00102 (e)Crane with grab Well foundation Per 4002.40
bucket 1 cum Hour
36 HIR-00014 Concrete bucket For pouring Per 14.00 As per WR
1.50 cum concrete Hour Dept. (S.No.14)

28
CFMS S o Rate for Remarks
Sl. Code Description 2021-22
Unit in Rs.
No.
Machine Activity
1 2 3 4 5 6 7
37 HIR-00103 Kerb casting Kerb making Per 570.30
machine Hour
HIR-00018 Concrete mixer Per 626.20 As per WR
Concrete mixing Dept. (S.No.18)
(a)0.28 cum Hour
38
HIR-00104 (b) 1.0 cum Concrete mixing Per 756.80
Hour
39 HIR-00105 Piling rig with 0.75 m dia to 1.20 Per 6499.60
bantonite pump m dia boring Hour
attachment
40 HIR-00106 Concrete paver Paving of concrete Per 3442.00
finisher with 40 HP surface Hour
motor
41 HIR-00107 Integrated stone Crushing of spalls Per 10340.50
crusher 100 TPH Hour
HIR-00108 Crushing of spalls Per 21804.00
200 TPH Hour
42 HIR-00109 Pre stressing jack 167.30
Stressing of steel Per
with pump and
wires/ stands Hour
access
43 Generator
HIR-00110 250 KVA Generation of per 2292.40
electric energy hour
HIR-00111 125 KVA per 1635.70
hour
HIR-00112 100 KVA per 1395.50
hour
HIR-00023 30 KVA per 1269.00 As per WR
hour Dept. (S.No.23)

44 HIR-00113 Pneumatic sinking Pneumatic sinking Per 6043.10


of Plants of wells K.m.
45 HIR-00058 1082.90 As per WR
Truck 5.5 cum per
Material transport Per her Dept. (S.No.58)
10 tonnes
46 HIR-00114 Road marking Road marking Per 143.70
Machine Hour
47 HIR-00114 Mobile slurry seal Mixing and laying Per 1337.10
equipment slurry seal Hour
48 HIR-00115 Plate compacter For compacting in Per 62.70
medians Hour
HIR-00022 As per WR
Per
49 Drilling equipment For drilling 1036.40 Dept. (S.No.22)
Hour
Note: The above hire charges of Machinery & Plant includes crew, oils, conveyance of
Machinery to site and all other incidental charges

29
SoR – 2021-22

Part – IV
PUBLIC HEALTH ITEMS

1
PUBLIC HEALTH ITEMS
Sl. Description Unit SoR for
No. 2021-22
1 2 3 4
1 RATES OF LABOUR
(SKILLED WORKMEN)

1. Caulker Per Day


2. Plumber 1st Class Per Day
3. Plumber 2nd Class Per Day
4. Sewer Cleaner Per Day
5. Well Sinker Per Day
As per Labor rates of SoR
6. Pipe line Fitter 1st Class Per Day
7. Pipe line Fitter 2nd Class Per Day
8. Pump Operator Per Day
9. Bore Mechanic Per Day
10. Light Vehicle Driver Per Day
Note: The rate at relevant item in
common SoR is applicable for
occasional employment.
2 RATES FOR EARTH WORK :
a. Earth work excavation in all
types soils for pipe lines, for
drainage and water supply, where
the depth is more than 1.5 times
the width.
b. Earth work excavation in all
types soils for pipe lines, for To follow the relevant items of
drainage and water supply, where Irrigation work items as per
the depth is less than 1.5 times AP. Standard data
the width.
c. Earth work excavation in all
types soils for open trenches, for
valve pits, inspection chambers,
etc.
3. Excavation of pipe line trenches
a. for drainage and water supply in
rock requiring blasting with
initial lead and lift including cost
of blasting materials where the
depth is more than 1.5 times the
width, in places where there is no
habitation.

2
b. Excavation of pipe line trenches
for drainage and water supply in
rock requiring blasting with
initial lead and lift including cost
of blasting materials where the
depth is less than 1.5 times the
width, in places where there is no
habitation.
c. Cutting rock for pipe line
trenches by hammers, knuckles
and chisels including stacking
where the depth is 1.5 times or
more than the width.
d. Cutting rock for pipe line
trenches by hammers, knuckles
and chisels including stacking
where the depth is less than 1.5
times the width.
e. Cutting rock for works other than
pipe lines trenches by hammers,
knuckles and chisels including
stacking.
f. For controlled blasting at
restricted places
NOTE: - Rock should be
measured in solids. In case it is
not possible, stacks should be
made in which case 40% for
voids to be deducted from the
stack measurements.
4 Loading or unloading materials
such as C.I. Pipes, PVC Pipes,
AC Pressure Pipes, DI Pipes, SW
Pipes, PVC Pipes, A.C/Specials
less than 300 mm dia. Up to 4 m
in length including stacking.
a. C.I. Pipes/D.I. Pipes and fittings Per Tonne To follow as per AP. Standard
b. A.C. Pipes & Specials Per Tonne data
c. Stoneware pipes & Specials Per Tonne
d. P.V.C. Pipes and fittings Per Tonne
5 Loading or unloading materials
such as C.I. Pipes, DI pipes, SW
pipes, AC pressure pipes &
fittings/ specials from 300 mm to
600 mm dia. Up to 4 m in length
including stacking.
a. C.I. Pipes/D.I. Pipes and fittings Per Tonne To follow as per AP. Standard
b. A.C. Pipes & Specials Per Tonne data

3
c. Stoneware pipes & Specials Per Tonne
6 Loading or unloading materials
such as C.I. Pipes, DI pipes, PVC
pipes, AC pipes less than 300
mm dia., above 4 m in length
including stacking.
a. C.I. Pipes/D.I. Pipes and fittings Per Tonne To follow as per AP. Standard
b. A.C. Pipes & Specials Per Tonne data
c. P.V.C. Pipes and fittings Per Tonne
7 Loading or unloading materials To follow as per AP. Standard
such as C.I. Pipes, DI pipes, AC data
pipes from 300 mm to 600 mm
above 4 m in length including
stacking.
a. C.I. Pipes/D.I. Pipes and fittings Per Tonne
b. A.C. Pipes & Specials Per Tonne
Note:- For loading and unloading
the above materials at Railway
Stations, the rates may be
adopted based on the competitive
quotations or the hummable
charges if prevailing.
8. Lowering C.I. / D.I. Pipes (all To follow as per AP. Standard
a. classes) and specials (fittings) data
with s/s ends carefully into
trenches and laying them true to
alignment and gradient including
all sundries but excluding cost
and conveyance of pipes from
source of supply (Ref to
specifications.
BIS No.3114/1994)
Diameter of Pipe/Fittings in mm
:
80mm to 1000mm dia. Per Meter

4
PUBLIC HEALTH ITEMS
Sl. Description Unit Code SoR rates for
No. 2021-22

1 2 3 4 5
8. Lowering C.I. / D.I. Pipes (all
b. classes) and specials (fittings)
with flanged ends carefully into
trench and laying them true to
alignment and gradient including
all sundries but excluding cost
and conveyance of pipes from
source of supply. (Reference to
specifications. BIS
No.3114/1994)
DIAMETER OF PIPE/Fittings in To follow as
mm : per AP.
80mm to 750mm dia. Standard data
800 Per Meter LAB-00587 655
900 Per Meter LAB-00588 852
1000 Per Meter LAB-00589 1107
1100 Per Meter LAB-00590 1363
1200 Per Meter LAB-00591 1620
9. Jointing CI /DI pipes & fittings
a. with s/s ends including cost of
pig lead, Spun yarn and sundries
such as cost of fuel for melting
lead, filling with water with lead
up to 500m and testing to
required pressure complete.
(Reference to specifications. BIS
No.3114/94/12288:1997)
DIAMETER OF PIPE/Fittings in To follow as
mm : per AP.
80mm to 800mm Standard data
900 Each Joint LAB-00592 17119
1000 Each Joint LAB-00593 19126
1100 Each Joint LAB-00594 21129
1200 Each Joint LAB-00595 23135
9. Jointing C.I., D.I. pipes and
b. fittings with rubber gasket (push-
on-joint),excluding the cost of
the gasket but including all
sundries filling with water, with
a water lead up to 500m and
testing to required pressure, etc.
complete
(Reference to specifications IS

5
3114/1994/12888/1997)

Diameter of Pipe/Fittings in mm To follow as per


: AP. Standard data
80mm to 1000mm dia. Each Joint
10 Jointing CI pipes, fittings and
valves with flanged ends
including cost of jointing
materials such as bolts, rubber
insertion, white lead including
filling with water, with lead up to
500 meters and testing to
required pressure complete.
(Reference to specifications. BIS
No.3114/1994.)
DIAMETER OF PIPE/Fittings/
valve in mm :
80mm to 750mm dia. Each Joint To follow as per AP. Standard
data
800 Each Joint LAB-00596 7178
900 Each Joint LAB-00597 8442
1000 Each Joint LAB-00598 9722
1100 Each Joint LAB-00599 11033
1200 Each Joint LAB-00600 12392
11a Lowering the RCC plain ended
pipes carefully into the trench
laying them true to alignment
and gradient, jointing RCC pipes
with cement joints including
curing, the cost of jointing
materials i.e., Cement Mortar
(1:1.5), hemp yarn etc., and
testing including filling with
water with a water lead up to 500
Meters excluding cost of rubber
rings as per BIS No.783/85.
per every 25 mm dia. Per Meter LAB-00601 25
11b Lowering the RCC S/S pipes
carefully into the readymade
trenches laying them true to
alignment and gradient, jointing
with rubber rings and testing
including filling with water with
a water lead up to 500 meters
including cost of rubber rings as

6
per BIS No. 783/1985

per every 25 mm dia. Per Meter


80mm to 600mm To follow as per AP. Standard
data
700 LAB-00602 396
800 LAB-00603 476
900 LAB-00604 570
1000 LAB-00605 684

12 Lowering and Jointing G.I. pipes


and specials / fittings including
excavation of trench of 0.5m
width and 0.50 m depth in all
soils except rock requiring
blasting and refilling trenches
after laying and jointing pipes
and also including cost of
jointing materials but excluding
the cost of pipes. Reference to
specifications. BIS No.783/85
a G.I. Pipes :Dia. in mm To follow as per AP. Standard
data
15mm to 150mm Per Meter
12- Laying, jointing of PVC/HDPE
b pipes as per BIS No.7634 part-
III/75 for PVC and BIS No.7634
part-II/75 for HDPE pipes
including trench excavation and
refilling.
DIA in mm
50 Per Meter LAB-00606 40
40 Per Meter LAB-00607 40
32 Per Meter LAB-00608 40
25 Per Meter LAB-00609 37
20 Per Meter LAB-00610 35
NOTE: - (i) The above rates are
applicable for the works in
District only.
(ii) If the depth of excavation is
more than 0.5 m separate rates to
be worked out.
13 Lowering and laying in
readymade trench true to
alignment and gradient, jointing,

7
and testing of Stone ware pipes
including cost of jointing
material such as cement mortar
(1:1) proportion and hemp yarn
but excluding cost and
conveyance of pipe. (Reference
to specifications BIS No.
6530/72)
Dia. of Pipes in mm To follow as per AP.
100mm to 450mm Per Meter Standard data

14 Lowering, Laying, Jointing and


Testing to hydraulic test pressure
including cost of water with
minimum water lead of 500m for
UPVC pressure pipes in
readymade trenches to alignment
and gradient including all
sundries but excluding cost &
conveyance of pipes from source
of supply and jointing material as
per BIS No: 7634 part-III-1975.
Dia. Of pipe Per Meter To follow as per AP.
63 to 315mm Standard data
15 Laying and jointing of HDPE
pipes by butt fusion welding as
per IS: 7634 – part-II/1975 as
amended from time to time to the
alignment and gradient and
testing the pipeline to the
required pressure.
Outer Dia. of pipes in MM
63 to 355 mm dia. To follow as per AP.
Standard data

400 LAB-00611 281


450 LAB-00612 311
16 Lowering, keeping in position
and fixing D.I. sluice valves
(with cap / with hand wheel &
Reflex valves) excluding cost of
bolts, nuts, rubber insertion,
sluice valve and tail pieces
Dia. of Valve in mm. To follow as per AP.
80mm to 600mm Each Standard data

17 Labor charges for fixing Air


valves including boring the

8
mains and threading the bore
fixing nipple etc., complete.
Dia. of Air valve in mm.
25 Each To follow as per A.P.
40 Each Standard data
50 Each LAB-00613 205
65 Each LAB-00614 217
80 Each LAB-00615 235
100 Each LAB-00616 279
125 Each LAB-00617 435
150 Each LAB-00618 476
18 Labor charges for fixing Kinetic
Air Valves with isolating Sluice
valves, Double Air valves/ Air
Cushion valve excluding cost of
jointing materials such as bolts,
nuts and rubber insertions etc.,
complete.
Dia. of Air valve in mm.
25 Each LAB-00619 193
40 Each LAB-00620 218
50(Double Air valves) Each LAB-00621 232
65 Each LAB-00622 249
80 Each LAB-00623 272
100 Each LAB-00624 316
125 Each LAB-00625 495
150 Each LAB-00626 542
19 Uprooting C.I. / DI Pipes by
melting the lead, loosening the
joints, scraping the pipes,
hoisting and keeping within a
lead of 10 m but excluding earth
work excavation and refilling.
80mm to 600mm Per Meter To follow as per AP.
Standard data
20 Uprooting of RCC pipes
including breaking the collars,
loosening the joint, separating
the pipes, hoisting and keeping
within a lead of 10 m but
excluding earthwork excavation
and refilling.
100mm to 300mm Per Meter To follow as per AP.
Standard data
21 Removing old G.I. pipes and
specials / fittings and cleaning,
scraping the pipes, hoisting and

9
keeping within 50m lead but
excluding earth work excavation
of trenches and refilling.
Dia. of Pipes in mm
15mm to 50mm Per Meter To follow as per AP.
Standard data

22 Cutting C.I./ DI Pipes without


water in mains Dia. of pipes in
mm.
Dia. of Pipes in mm
80mm to 600mm Each cut To follow as per AP. Standard
data
680 Each cut LAB-00627 601
700 Each cut LAB-00628 616
750 Each cut LAB-00629 665
800 Each cut LAB-00630 707
900 Each cut LAB-00631 794
1000 Each cut LAB-00632 882
1100 Each cut LAB-00633 972
1200 Each cut LAB-00634 1061
23 Cutting A.C. Pipes without water
in mains Dia. of pipes in mm.
Dia. of Pipes in mm
80 Each cut LAB-00635 39
100 Each cut LAB-00636 39
125 Each cut LAB-00637 39
150 Each cut LAB-00638 39
200 Each cut LAB-00639 41
250 Each cut LAB-00640 67
300 Each cut LAB-00641 67
350 Each cut LAB-00642 83
400 Each cut LAB-00643 91
450 Each cut LAB-00644 113
500 Each cut LAB-00645 126
600 Each cut LAB-00646 139
24 Drilling and tapping CI/ DI / GI
Main and fixing brass screw
down ferrule and plug.
10 mm to 20mm Each Tapping To follow as per AP.
25 mm to 40mm Each Tapping Standard data
25 Cutting road surface including
stacking of excavated materials
for pipe line trench work.
a) Cutting open B.T. road surface 10 Sqm LAB-00647 913
(as well as asphalt concrete up to

10
75 mm thick) including water
bound macadam
b) Cutting open C.C. road 1 Cum LAB-00648 2788
surface with concrete saw cutter
and removal with Breaker
c) Cutting open water bound 1 Cum LAB-00649 283
macadam road including soiling
26 Bailing out water.(For PH
item)
a) Bailing out water from the HP/Hour LAB-00650 To adopt the
pipe line trenches with oil engine rate arrived
driven pump sets, including hire for 5HP
charges, fuel charges and wages capacity pump
for Driver and Helper up to 5HP based on the
capacity pumps. WR
department
data.

b) Bailing out water from the HP/Hour LAB-00651 To adopt the


pipe line trenches with Electric rate arrived
Driven pump set including hire for 5HP
charges, current charges and capacity pump
wages for Driver and Helper up based on the
to 5HP capacity pumps. WR
department
data.

c) For capacity of Pumps more


than 5HP
A. Water lifting charges using
Electrical driven pump
i. per HP hr rate(including Per HP hr LAB-00652 Rs.10.24/-
contractors profit and overhead
charges of 13.615%
ii. Other expenses in terms of Per hr LAB-00653 Rs.166.78/-
Mazdoor, pump operator and
pipe laying and
dismantling(including
contractors profit and overhead
charges of 13.615%) per hr
Total hire charges of Electrically Per hr = (10.24xhp capacity) +166.78
driven dewatering pump per hour
B. Water lifting charges using
Diesel driven pump
i. per hphr rate(including Per hphr LAB-00655 Rs.25.51/-
contractors profit and overhead
charges of 13.615%
ii. Other expenses in terms of Per hr LAB-00656 Rs.201.55/-
Mazdoor, pump operator and

11
pipe laying and
dismantling(including
contractors profit and overhead
charges of 13.615%) per hr
Total hire charges of Diesel Per hr = (25.51xhp capacity)+201.55
driven dewatering pump per hour
NOTE:- The rate is payable on the total H.P. hours ignoring fractions less than 0.5 HP
hour and rounding off 0.5 HP hour or more to the next higher integer.
27 Shoring and strutting of trenches
for water and sewer main
a) Single Staging from (0 to 2.5 1 Sqm of To follow as per AP.
Mts.) Shoring area Standard data
b) Double staging from (2.5 m to 1 Sqm of
4.5 Mts.) Shoring area
28 Barricading, hoarding, lighting 1 RMT To follow as per AP.
and watching etc., for water Standard data
supply and sewerage works for
trenches.
29 Excavation of trenches for
infiltration galleries, siphon lines
and connecting mains in all soils
under water including all leads,
lifts, shoring, strutting, bailing
out water and removal of shoring
and strutting materials, after
completion of pipe line work.
a) 0 to 1 m deep under water. 10 Cum LAB-00658 13884
b) 1 to 2 m deep under water. 10 Cum LAB-00659 19888
c) 2 to 5 m deep under water. 10 Cum LAB-00660 29850
d) Beyond 5 m deep under water 10 Cum LAB-00661 5703
for every additional 1 m depth
over item 'c'
NOTE:- The above rates do not
include rock requiring blasting or
chiseling
30 Laying and jointing perforated Per Meter LAB-00662 43
RCC pipes inclusive of bailing
out water and jointing with
cement fillets and all other
incidental charges for infiltration
gallery inclusive of bailing out
water by pumping to keep the
trench reasonably dry to facilitate
the work excluding cost of
perforated pipes and collars.
Per every 25 mm dia.
31 Centering and scaffolding
charges for RCC members

12
including all materials and labor
charges for forming and
dismantling.
a) for RCC Elevated Service One Sqm of
Reservoir of staging up to 15 Centering area
Meter below L W L.
1) Slabs for thickness (150 mm LAB-00663
4229
to 300 mm)
2) Slabs for thickness above 300 LAB-00664 extra for
mm every 50mm
thickness
increase
Rs.473/-
3) Side walls curved surfaces. LAB-00665 3196
(rate is for both sides centering)
4) Side wall straight surfaces. LAB-00666 2843
(rate is for both sides centering)
5) Dome. LAB-00667 3465
6) Roof Slab. LAB-00668 1938
7) Column braces and beams LAB-00669 1427
8) Circular braces, ring beams & LAB-00670 1566
circular column.
Note: - For RCC ELSR of
staging above 15 m, the %
increase in these rates shall be as
follows.
15-18 m ---- 9%
18-21m --- 15%
21-24 m --- 21%
24 m -27m --27%
above27m --- 30%
Note: The Centering charges for item No’s.3 & 4 are for both the faces of the
respective numbers. The measurement of centering charges shall be in “Sqm” for
one face only and the centering charges given are for two faces of centering.

b) For Ground level works :-


1) Slabs 1 Sqm To follow as per AP.
2) Beams & Lintels 1 Cum Standard data
3) Sun shades 1 Sqm
4-a) RCC vertical walls of plane 1 Sqm of LAB-00671 1000/Sqm
surface (rate is for both sides centering area
centering) including open drains
4-b) VCC vertical walls of plane 1 Sqm of LAB-00672 980/ Sqm
surface (rate is for both sides centering area
centering) including open drains
5) RCC vertical walls of circular 1 Sqm of LAB-00673 1270/ Sqm
faces (rate is for both sides centering area
centering)
Note: The Centering charges for item No’s 4 & 5 are for both the faces of the

13
respective numbers. The measurement of centering charges shall be in “Sqm” for
one face only and the centering charges given are for two faces of centering.
32 Lift or delift of materials :
a) Lifting of cement concrete for 1 Cum
RCC elevated reservoir. For 169
every 1m height or part thereof LAB-00674
over the initial lift of 3 m
b) Delifting the materials such as 1 Cum
stones, concrete etc., for concrete
below ground level for
construction of masonry ground
level reservoirs, construction of
ground level reservoirs, LAB-00675 53
inspection wells, test wells and
sump wells etc., for every 1 m
depth or part there of beyond the
initial depth of 3 meters from
ground level.
39 Extra allowance for isolated Each 30% extra over
(a) scattered works viz., valve pits / the cost of
chambers, public fountains, chamber.
meter pits and manholes,
delivery cistern etc., complete.
(b) Repairs to the existing mains, 100% extra
interconnections, replacement of over the cost of
valves/specials etc., including the work
cutting, jointing, bailing out of
water, drying, earth work
excavation etc., complete.
40 Removal of wet silt and sludge 10 Cum LAB-00676 2871
by manual means from sullage
drains with aid of baskets and
vessels.
41 Well sinking in sandy and other
loose soils under water either by
manual labor, divers, or dredgers,
weighting the top of staining to
assist sinking etc., including
dewatering and other incidental
charges such as hire charges for
mechanical equipment etc.,
Up to 2 m below GL/m Per meter To adopt as per Standard data
From 2 to 4 m below GL/m Per meter
From 4 to 6 m below GL/m Per meter
From 6 to 8 m below GL/m Per meter
From 8 to 10 m below GL/m Per meter

14
42 Sinking in Hard strata other than Observed Data
rock but in soils like limestone,
gravel, clay under water
including, pumping dewatering,
hire charges for mechanical
equipment etc., complete.
43 Rates for OHSRs/ELSRs
including fixtures with a staging
of 15 m, without Seismic
analysis.
a 500 Kilo liters Per liter LAB-00677 20.07
b 1000 Kilo liters Per liter LAB-00678 16.67
c 1500 Kilo liters Per liter LAB-00679 15.03
d 2000 Kilo liters Per liter LAB-00680 13.08
e 2500 Kilo liters Per liter LAB-00681 12.26
1) The above rates are arrived with base rate of Cement Rs.3672/- per MT (as per
G.o.Ms.No.22 Dt:13-04-2020 of YSR NIRMAN) & Steel Rs 55000/- per MT(Fe 500)
(BoCE rates for the month of January-2021) and as per sand rates finalized by the
BoCE’s & communicated vide Lr. No .ENC/IW/SE(P&M)/EE.1/DEE.2/AEE(K)/SoR
2019-20/VOL-4 Dt:25-10-2019.
2) All concrete components shall be designed with M30 Design Mix proportion.
3) For intermediate capacities proportional rates shall be adopted.
4) The foundations shall be designed for Annular Raft Footings.
The above rates are applicable for Elevated Level Services Reservoirs / OHSRs for
SBC of 15 T/Sqm.
a) For every decrease of 2.50 T/Sqm of SBC, the rate shall be increased by 2.50% on
basic rate.
b) For every increase of 2.5 T/Sqm of SBC, the rate shall be decreased by1.0% on
basic rate up to 20 T/Sqm
c) For SBC below 10T/Sqm , solid raft shall be provided and for solid raft the rate shall
be increased by 10% on basic rate.
d) For SBC value of less than 5 T/Sqm, soil improvement shall be adopted, for which
additional payment shall be made as per field condition.
5) For staging less than 15 m, the rate shall be decreased by Rs.0.05 paisa on basic rate
per liter per every Meter decrease in staging.
6) For staging above 15 m, the rate shall be increased by Rs.0.10 paisa on basic rate per
liter per every Meter additional staging.
7) The above rates shall be increased / decreased due to increase/decrease in the cost of
cement by Basic rate x {(Rc-3672)/3672 } x 0.07
Rc = Rate of Cement (Rs per MT) at the time of preparation of estimate.
8) The above rates shall be increased / decreased due to increase/decrease in the cost of
Steel by Basic rate x { (Rs-55000)/55000} x0.2
Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate.
9) a) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner
surface of the Reservoir including roof.

15
b)The rate inclusive of 2 coats of weather proof emulsion painting for external
surfaces, lettering, all required fixtures, Pipes, Pipe specials, valves of DI material,
Valve chambers etc., for pipe connections including cost of pipes, specials and valves
as per departmental designs and drawings.
10) For tribal/Agency / Rural area, the above rates as arrived up to shall be increased
by 10%.
11) The above rates adopted for a wind pressure up to "250 kg/Sqm". For every 100
kg/Sqm decrease in wind pressure, the rate shall be decreased by 5%
12)
a) The Basic rate is adopted by considering the design for Seismic forces for Zone- II
only of seismic zones.
(b) The basic rates shall be increased by 15 % for Zone-III of seismic zones.
13-(a). The ELSR/OHSR shall be designed with minimum of two rows of columns for
capacities above 500 KL & up to 1000KL.

13-(b). The ELSR/OHSR shall be designed with minimum of three rows of columns
for capacities above 1000KL.
14. The shaft type staging with slip form can also be provided with proper approval
from competent authority without any additional cost.
15) The basic rate is inclusive of following Fixtures
i) Pipe connections & Specials with D.I materials
(a) All pipe connections for Inlet, Out let, Over Flow, Scour pipes shall be provided
with D/F DI material.
(b) The Valves for above pipe connections also shall be of DI material of PN 16 duty
confirming to the specification of SoR item No.28
(c) All specials such as Bends, Tees, Reducers, Duck foot Bends, Bell mouths etc,.
Shall be of DI material.
II) The sizes of the verticals for ELSR/OHSR shall be:
a) For 500 KL to 750 Kl ELSRs
Inlet Pipe - 300mm dia.
Out let Pipe - 350mm dia.
DI valves – 2 No’s
Over Flow pipe - 350m dia.
Scour Pipe - 200mm dia.
b) For 800 KL to 1500 Kl ELSRs
Inlet Pipe - 400mm dia.
Out let Pipe - 450mm dia.
DI valves – 2 No’s
Over Flow pipe - 450m dia.
Scour Pipe - 200mm dia.
c) For above 1500 KL to 2500 Kl ELSRs
Inlet Pipe - 400mm dia.
Out let Pipe - 500mm dia.
DI valves – 2 No’s
Over Flow pipe - 500m dia.
Scour Pipe - 200mm dia.

16
Note: Any deviation from the above sizes as per design, shall be paid or recovered.
(iii) Manhole Frames & Covers
a) All man hole Frames & Covers shall be made of CI/DI materials with min. size of
0.60mX 0.60m - For Roof & Valve Chambers.
iv) CI/D.I Double Swan neck ventilators (min. of 150mm dia.) shall be provided in top
dome and slab with mosquito/fly proof nets - 4Nos.
v) RCC Finial ventilator with fly/bird protection with GI mesh - 1 No.
vi) RCC precast ladders of 0.60 m width - 2 Nos.
vii) RCC dog legged stair case of 1.00 m flight width and 1.20 m landing width R.C.C
hand railing of 1.0 m height – 1 No
viii) The staircase shall be enclosed with brick masonry walls on three sides and
collapsible MS gate on front side up to 1st brace level, to prevent unauthorized entry.
ix) Construction of R.C.C valve chambers as per Standard Drawings with RCC cover
slab fixed with CI/DI manhole Frame & Cover with lock and Key arrangement. The
Mix shall not be less than VRCC M 20 grade with 150mm thick side walls, 150mm
thick top slab, 150mm thick base slab over base course of 100mm thick (1:4:8) prop.
x) Balcony of 1.00 m width at floor slab level / middle ring beam level by using
Stainless Steel pipe of grade 304 hand railing up to 1.20 m height, with top railing of
40mm dia. pipe & middle railing of 25mm dia. and verticals with 40mm dia. at an
interval not more than of 1.00m c/c.
xi) Water Level Indicator of reputed make – Digital type (1 No) and Conventional
type (1 No)
xii) Lightening Arrestor with all its accessories complete including earthing, with
relevant IS Codes - 1 No.
xiii) Compound wall: Construction of compound wall including ornamental M.S.Gate
of size 3.0 X 2.40m is included in the basic rate of ELSRs. Length of compound wall
hall is minimum of 150m. Min. height of the compound wall shall be 1.80m above
plinth and thickness 230mm in brick masonry in CM (1:6).The compound wall shall be
constructed including earth work excavation in all types of soils for plinth beam of
230mm X 300mm and 0.75X0.75X1.20m size for column footing portions. The
footings shall be of 0.75X0.75X0.25m in VRCC M20 grade and constructed over a
C.C (1:4:8) prop bed of 100mm thick. The columns shall be of 230X230 mm in size
with VRCC M20 grade at 3.00m c/c spacing, having depth of 1.20m below ground
level and height of 2.00m above GL. The plinth beam of size of 230X300 mm shall be
constructed in VRCC M20 grade at Ground level, over a bed of CC(1:4:8)-
100mmthick. 450X450mm size columns in M20 grade shall be constructed for gate
pillars. All the materials shall be followed as per the standards.
Tie beam shall be provided above the brick work with 230X200mm size, fixed with
MS angular of 25mm X 25mm X 4mm in "Y" shape to height of 0.60m, with
embedded length of 150mm in concrete. The barbed wire fencing with 3 ply of 18
gauges shall be stretched in 4 rows (2x2). Plastering shall be done with 16mm thick in
two coats i.e., base coat 12mm thick in CM(1:6)prop and 4mm thick 2nd coat CM(1:4)
prop on both sides of brick work.
Snowcem paint in two coats shall be provided for both sides of wall. The M.S
ornamental gate as per the approved drawings shall be provided with minimum of
3.60mts width and 2.40mts height with enamel paint. Yard lighting shall be arranged

17
on four corners of compound wall. If the length of the wall is increased/decreased

Note:-For every 1m increase/decrease in length of compound wall the


increase/decrease in basic rates of ELSRs of the capacities from 500KL to 2500KL
shall be as follows.:
i)500 KL : 0.086%
ii)1000 KL : 0.047%
iii)1500 KL : 0.034%
iv)2000 KL : 0.026%
v)2500 KL : 0.022 %
For intermediate capacities, interpolated percentages shall be adopted.
xiv) Staff Quarter shall be constructed for a minimum plinth area of 40 Sqm with the
following specification: RCC framed structure with concrete grade not less than M20
design mix at the locations specified by the department at the time of execution with
veranda, hall, bed room, kitchen and bath &W/C with floor area of 40.00sqmts
excluding balconies and staircases.
MS hollow door frame with cold rolled processed steel sheet 1.25mm thick bright
CRCA conforming to IS 4351/76, Flush door shutters with solid bond wood bond
board doors shall be provided. N.C.L. Windows centre fixed both sides open able
shutter window 1.35 X 1.35mts outer frame section 48 x50mm shutter frame section
with a size of 48 X20 mm mullion section of size 48 X 50mm fixed beading section of
12 X 12 mm shall be provided. Flooring with polished Kadapa stone shall be provided.
Walls shall be provided with snowcem paint in two coats over primary coat. Electrical
and water supply arrangement shall be provided as directed by dept officer. Water
Storage tank made with plastic/polymer material of reputed make with necessary out
let and inlet connection pipes shall be provided. Septic tank for 5 users shall be
provided.
44 Rates for OHSRs/ELSRs
including fixtures with a
Rs/liter
staging of 10 m without Seismic
analysis.
a Up to 10,000 Liters capacity Per liter LAB-00682 61.86
b 15,000 Liters capacity Per liter LAB-00683 46.20
c 20,000 Liters capacity Per liter LAB-00684 41.79
d 40,000 Liters capacity Per liter LAB-00685 35.43
e 60,000 Liters capacity Per liter LAB-00686 26.85
f 1,00,000 Liters capacity Per liter LAB-00687 24.77
g 2,00,000 Liters capacity Per liter LAB-00688 21.65
h 3,00,000 Liters capacity Per liter LAB-00689 20.37
i 4,00,000 Liters capacity Per liter LAB-00690 17.94
j 4,50,000 Liters capacity Per liter LAB-00691 15.51
NOTE: -1). All concrete members shall be designed with M30 grade design mix.
2) For intermediate ranges proportional rates may be adopted

18
2) The above rates are applicable for Elevated Level Services Reservoirs / OHSRs with
RAFT FOUNDATION and a rate of Rs.3672/- per tonne for cement (as per
G.o.Ms.No.22 Dt:13-04-2020 of YSR NIRMAN) and Rs.55000/- per tonne for steel(Fe
500) and as per sand rates finalized by the BoCE’s & communicated vide Lr. No
.ENC/IW/SE(P&M)/EE.1/DEE.2/AEE(K)/SoR 2019-20/VOL-4 Dt:25-10-2019.
3) For every Meter of staging less than 10 m, the rate shall be reduced by Rs.0.05
paisa per liter per every Meter of difference in staging
4) For every Meter of staging above 10 m , the rate shall be increase by Rs.0.10 paisa
per liter per every Meter of additional in staging

5) The above rates shall be increased / decreased due to increase / decrease in the cost
of cement by
Basic Rate x {(Rc-3672)/3672} x 0.07
Rc = Rate of cement (Rs per Mt) at the time of preparation of estimate.
6)The above rates shall be increased / decreased due to increase / decrease in the cost
of steel by
Basic Rate x { (Rs-55000)/55000 x0.2}
Rs = Rate of steel (Rs per Mt) at the time of preparation of estimate.
7) Rate inclusive of three coats of epoxy paint Food Grade of best quality to inner
surface of the Reservoir including roof.

8) The above rates shall be adopted for estimate purposes for construction of ELSR for
a finished work including 2 coats of whether proof emulsion painting for external
surfaces, lettering, all required fixtures, pipes, bends, valves etc., for pipe connections
but excluding cost of pipes, bends and valves as per departmental designs and
drawings.
9) The above rates are applicable for wind pressures up to 250 kg / Sq m .For decrease
in wind pressure the rate has to be decreased by 5% per every 100kg/Sqm. If the ELSR
/ OHSR are to be designed for seismic forces also, cost shall be arrived by working out
detailed quantities based on the designs.
10) (a)For tribal/Agency / Rural area, the above rates as arrived up to shall be increased
by 10%.
(b) An additional increase of 7.50% shall be allowed for OHSRs/ELSRs located in
agency areas over the above rates for RWS Department works.
11) If the ELSR is to be designed for seismic forces also, cost shall be arrived by
working out detailed quantities based on the design & difference to be paid extra.

12) If the ELSR is to be designed for seismic forces a) The above rates are applied up
to Zone-II earth quake. b) For Zone-III earth quake the above rates are to be increased
by 15 %.

13) The rate is arrived with the Cement rate of Rs.3672/- per MT (as per G.o.Ms.No.22
Dt:13-04-2020 of YSR NIRMAN) & Steel rate of 55000/(Fe 500)- approved by the
BoCE for the month of January-2021.
13) Fixtures include :
a) RCC or Aluminum ladder inside 0.60 m wide.

19
b) Spiral staircase on the outside shall be provided up to 200KL. Above 200KL
capacity dog legged staircase shall be provided with staircase flight width of 1.0mts
and landing width of 1.20mts with S.S railing up to 1.0 height.

c) Lightening arrestor, including conductor and earthling etc.

d) RCC ventilators with copper or stainless steel fly proof mesh.


e) D.I Manholes frame and cover 0.60x0.60 m as per IS specifications (light duty) - 2
Nos.
f) Water level indicator of good quality with ebonite/ copper float approved pattern - 1
No.
g) The ladder shall be with M.S ladder and Verticals with HDPE of 10kg/Sqcm shall be
provided for single column OHSRs only.
h) Minimum staging for all
ELSR/OHSR shall be 10.0mts.
i) The increase in staging shall be
at 1.0mt interval.
j) The railing provided to the gallery and stair case shall be with stainless steel of grade
304 for a height of 1.20mts.
k). The dog legged staircase shall be enclosed with brick/CRS wall on three sides and
front side with M.S collapsible gate up to 1st brace level from ground level to prevent
unauthorized entry.
l). D.I swan neck ventilators shall be provided in top dome and slab.
m). The above rates are exclusive of all inlet, out let connection and valves. All valves
near inlet, out let and for scour of ELSRs shall be D.I valves of heavy duty confirming
to the specification of SoR item No.28

45 Construction of Rapid Gravity


Filtration Plant including all
civil, mechanical and electrical
works using sand as filter
media, compatible with
SCADA arrangements, duly
following relevant IS codes in
the design of plant components
including trial running for 90
days etc., including chlorine
contact tank & consumables
etc., complete.
1) 2.0 MLD Per liter LAB-00692 4.87
2) 5.0 MLD Per liter LAB-00693 3.97
3) 10.0 MLD Per liter LAB-00694 3.58
4) 20.0 MLD Per liter LAB-00695 2.88
5) 30.00 MLD and above Per liter LAB-00696 2.50
NOTE :-
a) For Intermediate Capacities proportional rates may be adopted

20
b) The above rates are applicable with Cement @ rate of Rs.3672/- per MT (as per
G.o.Ms.No.22 Dt:13-04-2020 of YSR NIRMAN) and Steel of Rs. 55000/MT.(Fe 500)
and as per sand rates finalized by the BoCE’s & communicated vide Lr. No
.ENC/IW/SE(P&M)/EE.1/DEE.2/AEE(K)/SoR 2019-20/VOL-4 Dt:25-10-2019.
c) The above rates shall be increased / decreased due to increase / decrease in the cost
of cement by
Basic Rate x {(Rc-3672)/3672} x 0.07
Rc = Rate of cement (Rs per Mt) at the time of preparation of estimate
d) The above rates shall be increased / decreased due to increase / decrease in the cost
of steel by
Basic Rate x { (Rs-55000)/55000} x0.2
Rs = Rate of Steel (Rs per MT) at the time of preparation of estimate.

e) For Rural areas an extra allowance of 10% shall be given on basic rate

f) For SBC below 10T/Sqm , solid raft shall be provided and for solid raft the rate shall
be increased by 10% on basic rate.
g) For SBC value of less than 5 T/Sqm, soil improvement shall be adopted, for which
additional payment shall be made as per field condition.
h) For components immersed in water Stain less Steel of Grade 304L shall be used. for
other components 304 Grade steel shall be used.

i) Lab testing equipment of reputed make and consumables for one year. The testing
equipment for conducting all laboratory tests shall be installed & training shall be
imparted to the Municipal staff.
j) The rate is arrived with the Cement rate of Rs.3672/- per MT (as per G.o.Ms.No.22
Dt:13-04-2020 of YSR NIRMAN) & Steel rate of 55000/- approved by the BoCE for
the month of Janaury-2021.
The above rates of Filtration Plants shall include all the following components.
A) Civil Works
(All works of VRCC Shall be in M30 design mix)
1). Stilling Chamber and Aeration cascade
2) Pre settling tank shall be provided for 30 MLD and above capacities of WTP for a
minimum of 1 hr capacity.
3). Raw water channel with Stainless Steel Weir of SS 304 L Grade material and also
with digital flow meters
4) Flash Mixer chamber with Flash mixing arrangements including SS shaft & SS
Blades with gear wheel arrangements etc, using 304 L Grade Steel.

5-a) Clariflocculator / Flocculation tanks with the components of central driven circular
clarifier with scrapper & bridge arrangements made with Stainless Steel Grade 304 L
tubes /angular for durability & chemical resistant with wheel arrangements etc,
5-b) Two numbers of Clariflocculator shall be provided for WTP's of more than 30
MLD capacity.

6) Filter house, Chemical house, Alum store, Laboratory room, Chlorination plant
room, toilet etc. (All structures shall be provided RCC roof only).Chemical house &
Chlorinator rooms are to be isolated and shall be as per CPHEEO manual.

21
7) Wash water tank of suitable capacity shall be constructed at minimum clearance of
2.00m, above the roof slab of Filter beds / any other structure, and the minimum
residual head at the top of under drain system shall not be less than 8.0 meters.
8) Chlorine contact tank
9) All the Doors and Windows shall be of Best Teak wood/Aluminum / UPVC make,
except entrance door. The entrance door including shutter in filter house shall be with
best teak wood of minimum size of 2.40 X 2.40 mts.
a) Main Doors of all individual Buildings shall be made of Best Teak wood
b) Other Internal Doors of the buildings shall be of Compressed wood/ Aluminum/
UPVC materials.
c) Ventilators shall be provided for each building/structure of suitable size as per NBC
standards.
10) a) All pipes in Plant shall be of D.I., D/F materials. All Connecting pipes of the
plant components such as from Flash mixer to Clariflocculator/ Clarifier/Flocculation
tank, to Filter beds, sludge disposal pipes shall be of D.I., D/F material. The size of
sludge disposal pipe shall be minimum of 450 mm dia. with D.I D/F pipe and
minimum length of 100 meters.
b) All the Valves in Plant shall be heavy duty and as per the specification of SoR
item No.28
11) The Pipe gallery way for Clear water/ Back wash water/ pipe connections shall be
sufficiently spaced for easy operation & maintenance and inspection, as per standard
norms.
12) The bottom level of the wash water control chamber must be above G.L so as to
dispose the wash water and sludge from Clariflocculator by gravity to disposal point.
Additional specifications
13) Railing for all the components (Clariflocculator, Filter House, Staircase etc,.) shall
be provided with Stainless Steel of grade 304 for a height of 1.00m, with 40mm dia.
pipe for top horizotals,25mm dia. for middle row and 40mm dia. verticals spaced at
interval of not more than 1.00m c/c.
14) Inspection / Path ways in filter beds: Middle pathway: Minimum of 1.50m,
Side pathway: Minimum of 1.20m
15) Flooring in the buildings (Filter house, Chemical House, Chlorinator Room,
Laboratory) shall be provided with Non-skid tiles of approved make & quality, as per
standard specifications.
16) The basement of the Filtration plant building shall be minimum of 1.20m and pipe
gallery shall be minimum 0.3m above the existing nearby Road top level.
17) Minimum head room of 2.00m shall be provided, at the alum mixing chambers in
alum store for inspection & maintenance.
18) The minimum width of entrance hall for the Filter House shall be 4.50m, and
Laboratory of min size .of 3.30 X 4.50m.
18) b) For various components of the WTP should be designed by considering the
uplift pressure also.
19) a) High efficient Air Blowers shall be installed to the design requirement with low
noise pollution, environmental pollution as per PCB guide lines & Testing of blowers
as per I.S Standards at site. b) The Piping from Blower to Filter Beds shall be GI
and submerged pipe in water shall be HDPE.

22
20) UPVC pipes shall be provided for under drain system. Filter pipe manifolds shall
be assembled with HDPE pipes.

21) Alum storage capacity shall be designed for minimum period of 90 days.
Consumables shall be provided for 2115 Running Hours of WTP.

22) Chlorinator : Vacuum type chlorinator shall be provided with following


specifications:
a) Vacuum operated solution feeding type Vacuum Regulator, Rotameter, Rate setting
Valve, built-in NRV, Gas Overflow out let by man folding to mount the system with
the unit.
b) The unit shall consist of Ejector with necessary accessories such as Check Valve,
Drain Valve and Vacuum relief Valves - for control of chlorinator dosage.
c) The Accessories and manifolds shall be chlorine resistant and made of carbon steel
seam less pipes, copper tube with brass fittings of suitable size & dimensions, with
diaphragm sealed chlorine pressure gauge arrangements
d) Water Booster Pump of pumping capacity ranging from 2 cum/hr to 12 cum/hr, with
Head ranging from 16 to 35 m
e) The water & solution carrying pipes shall be made of UPVC material of suitable size
incl. all specials such as Tee's , Bends, couplings & NRVs and also Pressure Gauges of
suitable range.
f) Chlorine Gas Leak detector with alarm indicator.
The installation includes all necessary accessories, civil and mechanical works,
manifold header installations, injector fixing, connection with UPVC pipes, solution
piping’s, fixing of motors as per standard specifications and commissioning of
Chlorination Plant to the required demand, with a defect liability period of 1 year.
The chlorinator of may be of any reputed make or any make of Metito/Toshocow-Jesco
Siemens Industrial Devices.
g) Life breathing apparatus.
h) Chlorine escape BA set
i) 2 to 10 MLD Plants - 1Kg/hr Chlorinator- For Post Chlorination
ii) 10 MLD to 20 MLD Plants - 2 Kg/hr Chlorinator - For Post Chlorination.
iii) 20 MLD to 50 MLD Plants - 5 Kg/hr Chlorinator
- For Post Chlorination.
B) Mechanical Equipment
1) Alum dosing equipment with SS 304 material made stirrers & paddles for chemical
resistance. (Alum tanks must be bound with corrosion resistant material (HDPE Lining,
Bitumen Coating, tiles etc)
2) Flash mixer equipment with SS 304 material made stirrers & paddles for chemical
resistance.
3) Filtration plant equipment instrumentation and piping.
4) Clarifloccualation equipment (with stainless steel blades) with rotating bridge
arrangement etc.,
5) Pneumatic tyre wheel shall be provided for the bridge Clariflocculator.
6) Wash water tank fittings and pump sets with 100% stand by.
7) Air blower with motor of 100% stand by and pipe connections made with of SS
pipes confirming to SS 304 Grade, in filter bed region.
8) Chlorination equipment and pipe connections with chlorinator of 100% standby.

23
9) Spares & Tools for 2 years.
10) Gaseous Chlorination with cylinders has to be provided with protection measures.
C) Electrical Equipment
1) Necessary power supply wiring to motors and switches bus bar connections as per
IE Rules
2) Internal wiring and illumination and fittings and fixtures for internal and external
lighting exhaust fans, ceiling fans etc.
3) Erecting mechanical and electrical equipment, trial run for 90 days at 23.50 hours
per day testing the treated water as per CPHEEO standards and maintenance of records
and imparting training to staff.
4) Supply of 6 - Sets of completion plans and maintenance manual and brochures.
5) All cables shall be of copper material, Cable ducts shall be covered with MS /
Aluminum cheque plate.
6) Min LUX levels inside the treatment plant shall be maintained.
7) Yard lighting shall be provided as per norms.
D ) Equipment for Flow measurements
1) Equipment for measuring Conductivity, Turbidity, Ph value, Residual Chlorine with
recording & data storage facility (Computer based) & Alarm by SMS or other methods.
2) Off - Site Supervisory and Data Acquisition (OSSADA) system for Raw water &
Clear water flows by installing Digital Flow meters to measure the flows at Raw water
Channel and at each filter bed individually and combined for measuring the quantities
of water treated with a facility to record and store the readings & also to send
messages to the assigned designators about the variations/ deficiencies in the flow
including alerts for back wash requirements of filter beds, and recovery of data for the
past 360 days. All the Digital Flow Meters & Pressure Gauges shall be provided of
standard approved make. The equipment shall have the following specifications.
Hardware:
i) Wall mounted Sensor House for measuring Raw water & Clear water flow from
Filter bed out lets with accessories consists of
ii) Electrode Type: General type, Scraper type or replaceable type Electrode made with
material of SS external Ultra Touch Sensors as per requirement.
iii) Customized Application Requirement : Sensors with Interface logic control board
with serial interfaces, including accessories such as Add-on port, external DC Power
Socket, On - sensor Board Buffer, Timer, RS485 Communication, Analog to Digital
Sensing Sensor Circuit, 32 Sensors Sensing Tags, Interval Power Supply System ,
LCD 16c/2L, Filter Bed Working Status Indication LED, Filter Bed Wash Indication
Button and memory of Data Storage for 30Days , status of Filter Bed Level indicator,
Rating, Reading on LCB Display, Menu Driven Data for sending to Onsite Big
Display, operated with Battery Power of any reputed make or any equivalent make.
iv) Customized Application Requirement: Power Sensors Interface logic control board
with support 8 Power Sensing tags, Central System Interfacing Communication, On -
board analog to Digit Convert Integrate Circuit of any reputed make or any equivalent
make.

24
v) Customized Application Requirement: Centralized System with two serial
interfaces, 3 No’s of Add-On ports, One external DC Power Socket, On - Board
Buffer, On - Board Timer, On - Board RS485 Communication, On - Board RS 232
Communication, On - Board GPRS/GSM Module, On - Board Voice Chip, On - Board
Power Sensing Module, LCD 16c/2L, Filter Bed Wash Precaution Indication with Stop
Button, Memory of Data Storage for 30 Days, Total Bed Rating, Reading display on
LCD Display, Menu Driven, Menu Navigate Keypad, sending data to the Web Server,
Communication with GPRS , operated with Battery Power of any reputed make or any
equivalent make.
Software:
The software shall be designed with Web Domain with Data Base Server and Web
Name as per the directions of the Departmental Authorities.
The application of Software for Web design & Desktop shall meet the following
requirements:
i)Onsite Display: Letters with size of 1.5’ seven Segment LED Display with Interface
for each Filter Bed, for Onsite Display, by displaying the Bed Levels, Ratings,
Readings in 3 Columns, for each bed of the plant in successive rows and cumulative
results at the bottom of the screen.
ii) Off Site Display: Letters with size of 1.5’ seven Segment LED Display with
Interface GPRS/GSM Modules Offsite Display, with Display of Bed Total Rating,
Total Cumulative Reading as specified on On-site Display Features.
The system shall have also the features of Onsite Bed Wash Voice Precautions for Bed
Levels, Readings, Ratings, Bed Capacity Readings and Ratings and Bed Low Level
Triggering, before & after Bed wash.

The software shall also have the features of sending messages to the mobiles of the
Departmental designators indicating Bed Low Levels, Power Supply timings, Bed
Wash timings and its status, Power Supply timings and its status Grid View Table,
Motor Working time and its status Grid View Table, all trigger events and schedule
information and including all Snap View Reports, all Daily, Monthly, Yearly Reports,
all Power Working Reports, all Power Events Information etc,.

25
1. S o R FOR R.C.C. PLAIN ENDED PIPES
Sl. No. Description
Manufacture, Supply and Delivery of R.C.C. Plain ended pipes conforming to
1 B.I.S 458/2003,Ex -factory, excluding transportation and all taxes.

Size Unit SoR For 2021-22


Code NP- 2 Code NP - 3 Code NP - 4
Class Class Class
80 mm dia. Meter MAT- 137
05615
100 mm dia. Meter MAT- 159
05616
150 mm dia. Meter MAT- 189
05617
200 mm dia. Meter MAT- 225
05618
225 mm dia. Meter MAT- 244
05619
250 mm dia. Meter MAT- 257
05620
300 mm dia. Meter MAT- 373 MAT- 883 MAT- 895
05621 05636 05651
350 mm dia. Meter MAT- 463 MAT- 1048 MAT- 1068
05622 05637 05652
400 mm dia. Meter MAT- 536 MAT- 1154 MAT- 1181
05623 05638 05653
450 mm dia. Meter MAT- 655 MAT- 1327 MAT- 1343
05624 05639 05654
500 mm dia. Meter MAT- 715 MAT- 1432 MAT- 1655
05625 05640 05655
600 mm dia. Meter MAT- 1064 MAT- 2172 MAT- 2565
05626 05641 05656
700 mm dia. Meter MAT- 1356 MAT- 2690 MAT- 3437
05627 05642 05657
800 mm dia. Meter MAT- 1661 MAT- 3555 MAT- 4469
05628 05643 05658
900 mm dia. Meter MAT- 2099 MAT- 4459 MAT- 5581
05629 05644 05659
1000 mm dia. Meter MAT- 2567 MAT- 5455 MAT- 7658
05630 05645 05660
1100 mm dia. Meter MAT- 3020 MAT- 6552 MAT- 8866
05631 05646 05661
1200 mm dia. Meter MAT- 3600 MAT- 7714 MAT- 10362
05632 05647 05662
1400 mm dia. Meter MAT- 4933 MAT- 9930 MAT- 14280
05633 05648 05663
1600 mm dia. Meter MAT- 5671 MAT- 12875 MAT- 16964
05634 05649 05664
1800 mm dia. Meter MAT- 7472 MAT- 17067 MAT- 22727
05635 05650 05665
Note : All prices are ex-works.
The above rates of RCC Plain ended pipes are based on the following raw materials
Cost Cement. Rs.3672/- per MT (Excluding all taxes and freight).
Steel (M.S. Rods) - Rs.53000/- per MT. (Excluding all taxes and freight).

26
The revised cost of RCC pipes due to increase / decrease in the cost of raw materials shall be
as per the following formula.
Revised Cost =Cost as per the above table +R1+R2
R1= Variation (increase / decrease) in cost (Rs. per Meter) due to change in the
Cost of M.S. Rods = (S2-S1)/1000 X Ws.
R2= Variation (increase / decrease) in cost (Rs. per Meter) due to change in the
Cost of Cement = (C2-C1)/1000 X Wc.
S1 = Rs. 53000/- , S2 = Cost of M S Rods (Rs. per MT Excluding all taxes and freight)
at the time of preparation of estimate.
C1 = Rs. 3672/- C2 = Cost of Cement (Rs. per MT Excluding all taxes and freight)
at the time of preparation of estimate.
Ws=Weight of MS Rods required (Kg.) per Meter of pipe as per IS:458/2003.
Wc= Weight of Cement required (Kg.) per Meter of pipe.

27
2. S o R FOR R.C.C. COLLARS

Sl.No. Description
Manufacture, Supply and Delivery of R.C.C. Collars conforming to B.I.S. 458/2003 (rate
1 per each collar) suitable for R.C.C. Plain ended pipes including transportation but
excluding all taxes.
Size Unit SoR For 2021-22
Code NP - 2 Code NP - 3 Code NP - 4
Class Class Class
MAT-
80 mm dia. Each 05666
43
MAT-
100 mm dia. Each 05667
43
MAT-
150 mm dia. Each 05668
44
MAT-
200 mm dia. Each 05669
62
MAT-
225 mm dia. Each 05670
66
MAT-
250 mm dia. Each 05671
72
MAT- MAT- MAT-
300 mm dia. Each 05672
95 05687
133 05702
133
MAT- MAT- MAT-
350 mm dia. Each 05673
118 05688
169 05703
169
MAT- MAT- MAT-
400 mm dia. Each 05674
130 05689
193 05704
193
MAT- MAT- MAT-
450 mm dia. Each 05675
205
05690
258
05705
258
MAT- MAT- MAT-
500 mm dia. Each 05676
231
05691
309
05706
309
MAT- MAT- MAT-
600 mm dia. Each 05677
316 05692
402 05707
402
MAT- MAT- MAT-
700 mm dia. Each 05678
410
05693
538
05708
538
MAT- MAT- MAT-
800 mm dia. Each 05679
576
05694
689
05709
689
MAT- MAT- MAT-
900 mm dia. Each 05680
691
05695
803
05710
803
MAT- MAT- MAT-
1000 mm dia. Each 05681
809
05696
1002
05711
1002
MAT- MAT- MAT-
1100 mm dia. Each 05682
986
05697
1271
05712
1271
MAT- MAT- MAT-
1200 mm dia. Each 05683
1196 05698
1590 05713
1590
MAT- MAT- MAT-
1400 mm dia. Each 05684
1541
05699
2013
05714
2013
MAT- MAT- MAT-
1600 mm dia. Each 05685
1972
05700
2574
05715
2574
MAT- MAT- MAT-
1800 mm dia. Each 05686
1991
05701
3310
05716
3310

The above rates of RCC Collars suitable to plain ended pipes are based on the following raw
materials cost. Cement. Rs.3672/- per MT(Excluding all taxes and freight).
Steel (M.S. Rods) - Rs.53000/- per MT.(Excluding all taxes and freight).
The revised cost of RCC collars due to increase / decrease in the cost of raw materials shall be
as per the following formula.
Revised Cost =Cost as per the above table +R1+R2

28
R1= Variation (increase / decrease) in cost (Rs. per each)due to change in the cost of M.S.
Rods =(S2-S1)/1000 X Ws.
R2= Variation (increase /decrease) in cost (Rs. per each) due
to change in the cost of Cement = (C2-C1)/1000 X Wc.
S1 = Rs. 53000/- , S2 = Cost of M S Rods (Rs. per MT excluding all taxes and freight) at the
time of preparation of estimate.
C1 = Rs.3672/-,
C2 = Cost of Cement (Rs. per MT excluding all taxes and freight) at the time of preparation of
estimate
Ws=Weight of MS Rods required (Kg.) per each collar.
Wc= Weight of Cement required (Kg.) per each collar.

29
3. S o R FOR R.C.C. S/S PIPES (Non - Pressure)
Sl. No. Description
Manufacture, Supply and Delivery of R.C.C. Socket and Spigot pipes
1 conforming to B.I.S. 458/2003 at ex-factory (rate per meter of effective length)
Excluding transportation and all taxes.
Size Unit SoR For 2021-22
Code NP - Code NP - 3 Code NP - 4
2 Class Class
Class
MAT- 172
80 mm dia. Meter 05717
MAT- 195
100 mm dia. Meter 05718
Meter MAT- 228
150 mm dia. 05719
Meter MAT- 280
200 mm dia. 05720
Meter MAT- 303
225 mm dia. 05721
Meter MAT- 323
250 mm dia. 05722
Meter MAT- 456 MAT- 1139 MAT- 1203
300 mm dia. 05723 05738 05753
Meter MAT- 586 MAT- 1408 MAT- 1431
350 mm dia. 05724 05739 05754
Meter MAT- 644 MAT- 1561 MAT- 1586
400 mm dia. 05725 05740 05755
Meter MAT- 804 MAT- 1722 MAT- 1733
450 mm dia. 05726 05741 05756
Meter MAT- 926 MAT- 1967 MAT- 2135
500 mm dia. 05727 05742 05757
Meter MAT- 1300 MAT- 2758 MAT- 2783
600 mm dia. 05728 05743 05758
Meter MAT- 1683 MAT- 3523 MAT- 3608
700 mm dia. 05729 05744 05759
Meter MAT- 2164 MAT- 4665 MAT- 4691
800 mm dia. 05730 05745 05760
Meter MAT- 2743 MAT- 5859 MAT- 5922
900 mm dia. 05731 05746 05761
Meter MAT- 3348 MAT- 6578 MAT- 6794
1000 mm dia. 05732 05747 05762
Meter MAT- 3894 MAT- 7758 MAT- 8026
1100 mm dia. 05733 05748 05763
Meter MAT- 4392 MAT- 9158 MAT- 9393
1200 mm dia. 05734 05749 05764
Meter MAT- 6314 MAT- 12122 MAT- 13316
1400 mm dia. 05735 05750 05765
Meter MAT- 7813 MAT- 15733 MAT- 15824
1600 mm dia. 05736 05751 05766
Meter MAT- 8671 MAT- 20862 MAT- 21218
1800 mm dia. 05737 05752 05767
Note: All the prices are ex-works. The above rates of RCC S/S Non-Pressure pipes are based
on the following raw materials cost.
Cement. Rs.3672/- per MT,(Excluding all taxes and freight).
Steel (M.S. Rods) – Rs.53000/- per MT. (Excluding all taxes and freight).
The revised cost of RCC pipes due to increase / decrease in the cost of raw materials shall be
as per the following formula.

30
Revised Cost =Cost as per the above table +R1+R2
R1= Variation (increase / decrease) in cost (Rs. per Meter) due to change in the cost of
M.S. Rods = (S2-S1)/1000 X Ws.
R2= Variation (increase / decrease) in cost (Rs. per Meter) due to change in the cost of
Cement = (C2-C1)/1000 X Wc.
S1 = Rs. 53000/- , S2 = Cost of M S Rods (Rs. per MT excluding all taxes and freight) at
the time of preparation of estimate.
C1 = Rs. 3672/- , C2 = Cost of Cement (Rs. per MT excluding all taxes and freight) at the
time of preparation of estimate
Ws=Weight of MS Rods required (Kg.) per Meter of pipe as per IS: 458/2003.
WC= Weight of Cement required (Kg.) per Meter of pipe.

31
4. S o R FOR R.C.C. S/S PIPES (Pressure)
Sl.No. Description
Manufacture, Supply and Delivery of R.C.C. Socket and Spigot pipes
1 conforming to B.I.S. 458/2003 Ex-factory (rate per meter of effective length)
Excluding transportation and all taxes.
Size Unit SoR For 2021-22
Code P1 - Code P2 - Code P3 -
Class Class Class
Meter MAT- 231 MAT- 258 MAT- 295
80 mm dia. 05768 05786 05802
Meter MAT- 258 MAT- 310 MAT- 358
100 mm dia. 05769 05787 05803
Meter MAT- 358 MAT- 461 MAT- 568
150 mm dia. 05770 05788 05804
Meter MAT- 415 MAT- 596 MAT- 785
200 mm dia. 05771 05789 05805
Meter MAT- 467 MAT- 676 MAT- 873
225 mm dia. 05772 05790 05806
Meter MAT- 511 MAT- 719 MAT- 908
250 mm dia. 05773 05791 05807
Meter MAT- 686 MAT- 1031 MAT- 1278
300 mm dia. 05774 05792 05808
Meter MAT- 854 MAT- 1442 MAT- 1853
350 mm dia. 05775 05793 05809
Meter MAT- 1014 MAT- 1916 MAT- 2458
400 mm dia. 05776 05794 05810
Meter MAT- 1071 MAT- 2270 MAT- 3009
450 mm dia. 05777 05795 05811
Meter MAT- 1443 MAT- 2447 MAT- 3404
500 mm dia. 05778 05796 05812
Meter MAT- 1975 MAT- 3653 MAT- 4701
600 mm dia. 05779 05797 05813
Meter MAT- 2638 MAT- 4785 MAT- 5943
700 mm dia. 05780 05798 05814
Meter MAT- 3297 MAT- 5640 MAT- 7153
800 mm dia. 05781 05799 05815
Meter MAT- 3968 MAT- 6600
900 mm dia. 05782 05800
Meter MAT- 5038 MAT- 7539
1000 mm dia. 05783 05801
Meter MAT- 6054
1100 mm dia. 05784
1200 mm dia. Meter MAT- 7074
05785
Note: All the prices are ex-works.

The above rates of RCC S/S Pressure pipes are based on the following raw materials cost.
Cement. Rs.3672/- per MT,(Excluding all taxes and freight).
Steel (M.S. Rods) - Rs.53000/- per MT. (Excluding all taxes and freight).

The revised cost of RCC pipes due to increase / decrease in the cost of raw materials shall be
as per the following formula.

Revised Cost =Cost as per the above table +R1+R2

32
R1= Variation (increase / decrease) in cost (Rs. per Meter)due to change in the cost of M.S.
Rods = (S2-S1)/1000 X Ws.
R2= Variation (increase / decrease) in cost (Rs. per Meter)due to change in the cost of
Cement = (C2-C1)/1000 X Wc.
S1 = Rs. 53000/-
S2 = Cost of M S Rods (Rs. per MT excluding all taxes and freight) at the time of preparation
of estimate.
C1 = Rs. 3672/-, C2 = Cost of Cement (Rs. per MT excluding all taxes and freight) at the
time of preparation of estimate
Ws=Weight of MS Rods required (Kg) per Meter of pipe as per IS: 458 /2003.WC= Weight
of Cement required (Kg) per Meter of pipe.

33
5. S o R FOR RUBBER RINGS TO SUIT R.C.C. S/S PIPES

Sl.
Description
No.
Manufacture, Supply and Delivery of Rubber rings to suit R.C.C.Socket and
Spigot pipes conforming to B.I.S 5382/ 1985 (rate per each rubber ring)
1
including transportation but excluding all taxes. The Rubber Rings shall be
tested at the factory premises confirming to B.I.S. 5382/1985.
Size Unit SoR For 2021-22
Code NP - 2 Code NP - Code NP - 4
Class 3 Class
Class
MAT- 26
80 mm dia. Each 05816
MAT- 32
100 mm dia. Each 05817
MAT- 57
150 mm dia. Each 05818
MAT- 67
200 mm dia. Each 05819
MAT- 73
225 mm dia. Each 05820
MAT- 82
250 mm dia. Each 05821
MAT- 100 MAT- 129 MAT- 129
300 mm dia. Each 05822 05837 05852
MAT- 116 MAT- 154 MAT- 154
350 mm dia. Each 05823 05838 05853
MAT- 128 MAT- 175 MAT- 175
400 mm dia. Each 05824 05839 05854
MAT- 145 MAT- 198 MAT- 198
450 mm dia. Each 05825 05840 05855
MAT- 189 MAT- 227 MAT- 227
500 mm dia. Each 05826 05841 05856
MAT- 248 MAT- 329 MAT- 329
600 mm dia. Each 05827 05842 05857
MAT- 248 MAT- 394 MAT- 394
700 mm dia. Each 05828 05843 05858
MAT- 428 MAT- 478 MAT- 478
800 mm dia. Each 05829 05844 05859
MAT- 536 MAT- 646 MAT- 646
900 mm dia. Each 05830 05845 05860
MAT- 627 MAT- 780 MAT- 780
1000 mm dia. Each 05831 05846 05861
MAT- 754 MAT- 999 MAT- 999
1100 mm dia. Each 05832 05847 05862
MAT- 1208 MAT- 1256 MAT- 1256
1200 mm dia. Each 05833 05848 05863
MAT- 1328 MAT- 1382 MAT- 1382
1400 mm dia. Each 05834 05849 05864
MAT- 1654 MAT- 1686 MAT- 1686
1600 mm dia. Each 05835 05850 05865
MAT- 2060 MAT- 2154 MAT- 2154
1800 mm dia. Each 05836 05851 05866

34
Manufacture, Supply and Delivery of Rubber rings to suit R.C.C. Socket and
Spigot pipes conforming to B.I.S 5382/ 1985 (rate per each rubber ring)
2
including transportation but excluding all taxes. The Rubber Rings shall be
tested at the factory premises confirming to B.I.S. 5382/1985.
P1- P2- P3-
Size Code Code Code
Class Class Class
MAT- 26 MAT- 26 MAT- 26
80 mm dia. Each 05867 05885 05901
MAT- 32 MAT- 33 MAT- 33
100 mm dia. Each 05868 05886 05902
MAT- 57 MAT- 57 MAT- 57
150 mm dia. Each 05869 05887 05903
MAT- 67 MAT- 67 MAT- 67
200 mm dia. Each 05870 05888 05904
MAT- 73 MAT- 75 MAT- 77
225 mm dia. Each 05871 05889 05905
MAT- 82 MAT- 85 MAT- 86
250 mm dia. Each 05872 05890 05906
MAT- 100 MAT- 106 MAT- 110
300 mm dia. Each 05873 05891 05907
MAT- 116 MAT- 132 MAT- 145
350 mm dia. Each 05874 05892 05908
MAT- 128 MAT- 175 MAT- 178
400 mm dia. Each 05875 05893 05909
450 mm dia. Each MAT- 145 MAT- 200 MAT- 205
05876 05894 05910
500 mm dia. Each MAT- 189 MAT- 227 MAT- 237
05877 05895 05911
600 mm dia. Each MAT- 248 MAT- 280 MAT- 285
05878 05896 05912
700 mm dia. Each MAT- 338 MAT- 370 MAT- 394
05879 05897 05913
800 mm dia. Each MAT- 428 MAT- 474 MAT- 474
05880 05898 05914
900 mm dia. Each MAT- 536 MAT- 598
05881 05899
1000 mm dia. Each MAT- 627 MAT- 722
05882 05900
1100 mm dia. Each MAT- 754
05883
1200 mm dia. Each MAT- 1208
05884

35
6. S o R FOR CONVEYANCE OF R.C.C. PLAIN ENDED PIPES

Rate up to
5 Kms Rate for
Rate up to 5 Kms Rate for
Lead every
Lead including every
including additional
Sl.No. Description Loading, additional 1
Loading, 1 KM lead
unloading and KM lead or
unloading or part
stacking part thereof.
and thereof.
stacking
Conveyance of R.C.C plain ended pipes on all weathered roads including
1
loading, unloading and stacking (per Meter) SoR for 2020-21
NP - 2 Class NP - 3 Class & NP - 4 Class
80 mm dia. 4.00 0.17
100 mm dia. 5.32 0.17
150 mm dia. 7.99 0.32
200 mm dia. 10.65 0.32
225 mm dia. 11.98 0.51
250 mm dia. 13.31 0.51
300 mm dia. 18.65 0.68 51.92 1.36
350 mm dia. 26.63 1.52 55.92 1.52
400 mm dia. 29.30 1.69 66.57 2.02
450 mm dia. 38.61 2.02 71.89 2.36
500 mm dia. 41.28 2.36 78.55 2.36
600 mm dia. 59.90 3.71 118.48 5.24
700 mm dia. 75.88 5.24 131.80 6.08
800 mm dia. 89.20 5.24 158.42 6.08
900 mm dia. 102.50 5.24 207.68 11.48
1000 mm dia. 151.77 10.80 250.28 11.48
1100 mm dia. 166.40 10.80 271.58 12.49
1200 mm dia. 189.04 11.48 303.53 12.49
1400 mm dia. 227.65 11.48 412.70 13.00
1600 mm dia. 263.60 11.48 495.23 13.00
1800 mm dia. 303.53 11.48 660.31 18.24

36
7. S o R FOR CONVEYANCE OF R.C.C. S/S PIPES

Rate up to 5 Rate for


Rate up to 5 Kms Rate for
Kms Lead every
Lead including every
Sl. including additional
Description Loading, additional 1
No. Loading, 1 KM lead
unloading & KM lead or
unloading or part
stacking part thereof.
and stacking thereof.
Conveyance of R.C.C. Socket and Spigot pipes on all-weather roads including loading,
1 unloading and stacking (per Meter of effective length)

Size NP - 2 & P1 Class NP – 3 & NP - 4 Class


80 mm dia. 5.32 0.16

100 mm dia. 5.32 0.30

150 mm dia. 9.32 0.30

200 mm dia. 11.98 0.61

225 mm dia. 13.31 0.61

250 mm dia. 14.65 1.38

300 mm dia. 23.97 1.53 62.98 1.84

350 mm dia. 27.95 1.69 68.47 2.14

400 mm dia. 27.95 1.99 84.90 4.00

450 mm dia. 39.94 2.14 93.11 4.00

500 mm dia. 43.93 2.31 102.70 4.30

600 mm dia. 57.25 4.00 138.30 6.13

700 mm dia. 70.55 4.30 186.22 12.12

800 mm dia. 97.18 6.59 220.46 12.12

900 mm dia. 145.11 11.82 254.69 12.12

1000 mm dia. 165.08 11.82 268.38 12.12

1100 mm dia. 186.38 12.12 287.55 12.12

1200 mm dia. 207.68 12.12 321.78 12.42

1400 mm dia. 258.27 12.12 431.33 12.42

1600 mm dia. 306.20 12.42 509.39 13.35

1800 mm dia. 379.41 12.42 679.17 18.26

P2 – Class P3 – Class

80 mm dia. 5.32 0.16 5.32 0.16

100 mm dia. 5.32 0.30 5.32 0.30

37
150 mm dia. 9.32 0.30 9.32 0.30

200 mm dia. 11.98 0.61 15.97 1.38

225 mm dia. 15.97 1.38 18.65 1.53

250 mm dia. 17.30 1.53 22.63 1.69

300 mm dia. 33.27 1.84 38.61 1.99

350 mm dia. 41.28 2.14 53.26 2.31

400 mm dia. 49.26 2.31 70.55 4.00

450 mm dia. 62.57 3.84 87.87 4.00

500 mm dia. 70.55 4.00 106.50 5.99

600 mm dia. 93.20 4.00 154.42 7.67

700 mm dia. 139.78 8.13 224.98 12.12

800 mm dia. 185.05 11.51 287.55 12.12

900 mm dia. 224.98 12.12

1000 mm dia. 276.91 12.42

38
8. S o R FOR A.C. PIPES

Sl.No Description
1 2
Manufacture, Supply of A.C. Pressure pipes (Mazza process) as per BIS No: 1592/2003as
amended from time to time duly marked with BIS mark, including cost of material, incidental
1 handling, loading and packing charges, but exclusive of transportation, unloading, stacking at
departmental stores, and excluding all taxes. The pipes shall be tested at factory premises
confirming to IS Code 1592/2003.
Size Unit SoR For 2021-22
Class Class Class
Code Code Code
– 15 – 20 - 25
MAT- MAT- MAT-
80 mm dia. Rate/Meter 05915
206 05933
225 05951
281
Rate/Meter MAT- MAT- MAT-
100 mm dia. 05916
271 05934
344 05952
423
Rate/Meter MAT- MAT- MAT-
125 mm dia. 05917
354 05935
441 05953
552
Rate/Meter MAT- MAT- MAT-
150 mm dia. 05918
498 05936
618 05954
778
Rate/Meter MAT- MAT- MAT-
200 mm dia. 05919
825 05937
1055 05955
1340
Rate/Meter MAT- MAT- MAT-
250 mm dia. 05920
1048 05938
1357 05956
1698
Rate/Meter MAT- MAT- MAT-
300 mm dia. 05921
1466 05939
1906 05957
2434
Rate/Meter MAT- MAT- MAT-
350 mm dia. 05922
1786 05940
2321 05958
2924
Rate/Meter MAT- MAT- MAT-
400 mm dia. 05923
2322 05941
3035 05959
3767
Rate/Meter MAT- MAT- MAT-
450 mm dia. 05924
2753 05942
3653 05960
4574
Rate/Meter MAT- MAT- MAT-
500 mm dia. 05925
3402 05943
4468 05961
5611
Rate/Meter MAT- MAT- MAT-
600 mm dia. 05926
4834 05944
6312 05962
8043
Rate/Meter MAT- MAT- MAT-
700 mm dia. 05927
6401 05945
8681 05963
11226
Rate/Meter MAT- MAT- MAT-
750 mm dia. 05928
7293 05946
10021 05964
12847
Rate/Meter MAT- MAT- MAT-
800 mm dia. 05929
8346 05947
11355 05965
14572
Rate/Meter MAT- MAT- MAT-
850 mm dia. 05930
9361 05948
12775 05966
16409
Rate/Meter MAT- MAT- MAT-
900 mm dia. 05931
10436 05949
14270 05967
18355
1000 mm Rate/Meter MAT- MAT- MAT-
05932 12884 05950 17521 05968 22572
dia.
2 Lowering, laying and jointing of AC pressure pipes with AC couplings or CID joints
complete with Rubber rings in readymade trenches true to alignment and gradient including
filling with water lead up to 500 mts and testing to required pressure including all sundries
but excluding cost of jointing materials and conveyance from source of supply as per BIS No.
6530/1972
LAB- LAB- LAB-
80 mm dia. Rate/Meter 00697
54 00715
54 00733
54
Rate/Meter LAB- LAB- LAB-
100 mm dia. 00698
78 00716
78 00734
78

39
Rate/Meter LAB- LAB- LAB-
125 mm dia. 00699
85 00717
85 00735
85
Rate/Meter LAB- LAB- LAB-
150 mm dia. 00700
102 00718
102 00736
102
Rate/Meter LAB- LAB- LAB-
200 mm dia. 00701
134 00719
134 00737
134
Rate/Meter LAB- LAB- LAB-
250 mm dia. 00702
161 00720
161 00738
161
Rate/Meter LAB- LAB- LAB-
300 mm dia. 00703
197 00721
197 00739
197
Rate/Meter LAB- LAB- LAB-
350 mm dia. 00704
334 00722
334 00740
334
Rate/Meter LAB- LAB- LAB-
400 mm dia. 00705
504 00723
504 00741
504
Rate/Meter LAB- LAB- LAB-
450 mm dia. 00706
612 00724
612 00742
612
Rate/Meter LAB- LAB- LAB-
500 mm dia. 00707
777 00725
777 00743
777
Rate/Meter LAB- LAB- LAB-
600 mm dia. 00708
836 00726
836 00744
836
Rate/Meter LAB- LAB- LAB-
700 mm dia. 00709
932 00727
932 00745
932
Rate/Meter LAB- LAB- LAB-
750 mm dia. 00710
1037 00728
1037 00746
1037
Rate/Meter LAB- LAB- LAB-
800 mm dia. 00711
1092 00729
1092 00747
1092
Rate/Meter LAB- LAB- LAB-
850 mm dia. 00712
1166 00730
1166 00748
1166
Rate/Meter LAB- LAB- LAB-
900 mm dia. 00713
1271 00731
1271 00749
1271
1000 mm Rate/Meter LAB- LAB- LAB-
00714 1308 00732 1308 00750 1308
dia.
1. The above rates of AC Pipes are based on the Cement cost of RS 3672/- per MT
(Excluding all taxes and freight).
2. The above rates of AC pipes are based on the Fiber cost of Rs 78,500/- per M.T (Excluding
all taxes &Freight)
For any Increase/ Decrease in the rate of cement, the price of AC pipe per Rmt shall be
increased/decreased as under.
W x 0.85 x IC Where W = Weight of pipe in Kg’s/Rmt
IC = Increase/Decrease in cost of cement/Kg
For any increase/decrease in the rate of fiber, the price of AC pipe per Rmt shall be
increased/Decreased as under :
W x 0.15 X IF Where : W=: Weight of pipe in Kg’s/Rmt
IF = Increase /Decrease in cost of fiber/Kg
Note: 1) The Fiber rates are to be obtained from A.C. Pipe manufacturer of “Mazza” process.
2) The cement rate shall be communicated by the sub-committee of Board of Chief
engineers.
Transportation of AC pressure pipes at site of work anywhere in Andhra 5% on the basic
Pradesh on motor able roads for full truck loads including transit cost of
insurance, unloading, and stacking at site of work etc. Complete (AC corresponding
Couplings and Rubber rings are to be supplied free of transportation AC Pressure
charges). pipes.

40
9. S o R FOR A.C. COUPLINGS

Sl.
Description
No.
Manufacture, Supply of A.C Couplings suitable to A.C. Pressure pipes (Mazza process)
as per BIS: 1592/2003 excluding cost of rubber rings to suit AC pressure pipes
1 including cost of material, incidental handling, packing, transportation and unloading at
site transit risk, but excluding all taxes and testing of joints as per IS Code.
Size Unit SoR For 2021-22
Class Class Class
Code Code Code
– 15 - 20 – 25
MAT- MAT- MAT-
80 mm dia. Rate/Each 05969
99
05987
107
06005
123
MAT- MAT- MAT-
100 mm dia. Rate/Each 05970
129
05988
139
06006
166
MAT- MAT- MAT-
125 mm dia. Rate/Each 05971
162 05989
177 06007
213
MAT- MAT- MAT-
150 mm dia. Rate/Each 05972
189 05990
235 06008
291
MAT- MAT- MAT-
200 mm dia. Rate/Each 05973
347
05991
378
06009
481
MAT- MAT- MAT-
250 mm dia. Rate/Each 05974
404
05992
509
06010
649
MAT- MAT- MAT-
300 mm dia. Rate/Each 05975
527
05993
683
06011
879
MAT- MAT- MAT-
350 mm dia. Rate/Each 05976
685
05994
883
06012
1128
MAT- MAT- MAT-
400 mm dia. Rate/Each 05977
1054
05995
1376
06013
1764
MAT- MAT- MAT-
450 mm dia. Rate/Each 05978
1261
05996
1665
06014
2139
MAT- MAT- MAT-
500 mm dia. Rate/Each 05979
1506
05997
2015
06015
2573
MAT- MAT- MAT-
600 mm dia. Rate/Each 05980
1844
05998
2312
06016
2956
MAT- MAT- MAT-
700 mm dia. Rate/Each 05981
2438 05999
3281 06017
4267
MAT- MAT- MAT-
750 mm dia. Rate/Each 05982
2750
06000
3760
06018
4854
MAT- MAT- MAT-
800 mm dia. Rate/Each 05983
3120 06001
4230 06019
5475
MAT- MAT- MAT-
850 mm dia. Rate/Each 05984
3477
06002
4732
06020
6136
MAT- MAT- MAT-
900 mm dia. Rate/Each 05985
3846
06003
5261
06021
6829
MAT- MAT- MAT-
1000 mm dia. Rate/Each 05986
4695 06004
6396 06022
8336

1. The above rates of AC Coupling are based on the Cement cost of RS 3672/- per MT (Excluding all
taxes and freight).
2. The above rates of AC Coupling are based on the Fiber cost of Rs 78,500/- per M.T (excluding all
taxes &Fright)
For any Increase/ Decrease in the rate of cement, the price of AC Coupling per Each shall be
increased/decreased as under.
W x 0.85 x IC Where W = Weight of Coupling in Kgs/each
IC = Increase/Decrease in cost of cement/kg

41
For any increase/decrease in the rate of fiber, the price of AC Coupling per each shall be
increased/Decreased as under:
W x 0.15 X IF Where: W= Weight of Coupling in Kgs/Each
IF = Increase /Decrease in cost of fiber/kg

The Fiber rates are to be obtained from A.C. Pipe manufacturer of “Mazza” process.

42
10. S o R FOR RUBBER RINGS TO SUIT A.C. COUPLINGS

Sl. No. Description


Schedule of rate for supply of Rubber rings manufactured as per BIS: 5382/1988 with BIS
Mark embossed per each set suitable for A.C. Couplings including cost of material,
1 incidental, handling, packing and transportation and unloading at site transit risk etc., but
excluding all taxes. The Rubber Rings shall be tested at the factory premises confirming to
B.I.S 5382/1988
Size Unit SoR for 2021-22
Class Class Class
Code Code Code
– 15 – 20 - 25
MAT- 75 MAT- 75 MAT- 75
80 mm dia. Each Set 06023 06041 06059
MAT- 91 MAT- 91 MAT- 91
100 mm dia. Each Set 06024 06042 06060
MAT- 119 MAT- 119 MAT- 119
125 mm dia. Each Set 06025 06043 06061
MAT- 150 MAT- 150 MAT- 150
150 mm dia. Each Set 06026 06044 06062
MAT- 156 MAT- 156 MAT- 156
200 mm dia. Each Set 06027 06045 06063
MAT- 180 MAT- 180 MAT- 180
250 mm dia. Each Set 06028 06046 06064
MAT- 180 MAT- 180 MAT- 180
300 mm dia. Each Set 06029 06047 06065
MAT- 205 MAT- 205 MAT- 205
350 mm dia. Each Set 06030 06048 06066
MAT- 251 MAT- 251 MAT- 251
400 mm dia. Each Set 06031 06049 06067
MAT- 294 MAT- 294 MAT- 294
450 mm dia. Each Set 06032 06050 06068
MAT- 340 MAT- 340 MAT- 340
500 mm dia. Each Set 06033 06051 06069
MAT- 385 MAT- 385 MAT- 385
600 mm dia. Each Set 06034 06052 06070
MAT- 800 MAT- 800 MAT- 800
700 mm dia. Each Set 06035 06053 06071
MAT- 831 MAT- 831 MAT- 831
750 mm dia. Each Set 06036 06054 06072
MAT- 892 MAT- 892 MAT- 892
800 mm dia. Each Set 06037 06055 06073
MAT- 994 MAT- 994 MAT- 994
850 mm dia. Each Set 06038 06056 06074
MAT- 1045 MAT- 1045 MAT- 1045
900 mm dia. Each Set 06039 06057 06075
MAT- 1158 MAT- 1158 MAT- 1158
1000 mm dia. Each Set 06040 06058 06076

43
11. S o R FOR PRE-STRESSED (NON-CYLINDER) CONCRETE PIPES FOR THE YEAR 2021-22
Sl.No. Description
Manufacture, Supply, Delivery of Pre-stressed (Non-cylinder) concrete pipes conforming to IS 784/2001 ex-factory excluding
1 transportation, taxes For the following Field/Site Test Pressures.
(The manufacture shall design the pipes as per the IS Code 784-2001)
Size Unit SoR for 2021-22.
6 8 10 12 14 16
Code Code Code Code Code Code
Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2
350 MM MAT- 3285 MAT- 3297 MAT- 3310 MAT- 3327 MAT- 3394 MAT- 3512
Meter 06077 06096 06115 06134 06153 06172
DIA.
400 MM Meter MAT- 3530 MAT- 3556 MAT- 3594 MAT- 3641 MAT- 3709 MAT- 3764
DIA. 06078 06097 06116 06135 06154 06173
450 MM Meter MAT- 3753 MAT- 3771 MAT- 3814 MAT- 3887 MAT- 3987 MAT- 4074
DIA. 06079 06098 06117 06136 06155 06174
500 MM Meter MAT- 4062 MAT- 4079 MAT- 4113 MAT- 4199 MAT- 4287 MAT- 4413
DIA. 06080 06099 06118 06137 06156 06175
600 MM Meter MAT- 4663 MAT- 4697 MAT- 4746 MAT- 4892 MAT- 5048 MAT- 5203
DIA. 06081 06100 06119 06138 06157 06176
700 MM Meter MAT- 5467 MAT- 5545 MAT- 5675 MAT- 5837 MAT- 6006 MAT- 6241
DIA. 06082 06101 06120 06139 06158 06177
800 MM Meter MAT- 6633 MAT- 6781 MAT- 6938 MAT- 7148 MAT- 7365 MAT- 7706
DIA. 06083 06102 06121 06140 06159 06178
900 MM Meter MAT- 7610 MAT- 7806 MAT- 8010 MAT- 8353 MAT- 8618 MAT- 9243
DIA. 06084 06103 06122 06141 06160 06179
1000 Meter MAT- 8970 MAT- 9226 MAT- 9494 MAT- 9764 MAT- 10093 MAT- 10813
MM 06085 06104 06123 06142 06161 06180
DIA.
1100 Meter MAT- 10045 MAT- 10339 MAT- 10667 MAT- 10996 MAT- 11341 MAT- 12226
MM 06086 06105 06124 06143 06162 06181
DIA.
1200 Meter MAT- 11290 MAT- 11678 MAT- 12045 MAT- 12307 MAT- 12808 MAT- 14085
06087 06106 06125 06144 06163 06182

44
MM
DIA.
1300 Meter MAT- 12794 MAT- 13232 MAT- 13670 MAT- 14111 MAT- 15377 MAT- 15932
MM 06088 06107 06126 06145 06164 06183
DIA.
1400 Meter MAT- 14809 MAT- 15322 MAT- 15846 MAT- 16712 MAT- 17771 MAT- 18554
MM 06089 06108 06127 06146 06165 06184
DIA.
1500 Meter MAT- 16721 MAT- 17330 MAT- 17903 MAT- 19433 MAT- 20133 MAT- 22490
MM 06090 06109 06128 06147 06166 06185
DIA.
1600 Meter MAT- 18801 MAT- 19458 MAT- 20117 MAT- 21949 MAT- 22741 MAT- 25022
MM 06091 06110 06129 06148 06167 06186
DIA.
1700 Meter MAT- 20174 MAT- 20938 MAT- 21691 MAT- 23620 MAT- 26169 MAT- 27347
MM 06092 06111 06130 06149 06168 06187
DIA.
1800 Meter MAT- 22307 MAT- 23731 MAT- 25023 MAT- 27133 MAT- 28138 MAT- 31158
MM 06093 06112 06131 06150 06169 06188
DIA.
1900 Meter MAT- 23809 MAT- 25119 MAT- 27329 MAT- 28897 MAT- 31414 MAT- 33828
MM 06094 06113 06132 06151 06170 06189
DIA.
2000 Meter MAT- 26172 MAT- 27805 MAT- 29264 MAT- 31931 MAT- 35241 MAT- 36631
MM 06095 06114 06133 06152 06171 06190
DIA.
Cost of lowering, laying jointing, testing to Hydrostatic field test pressure as per IS: 783 including cost of Rubber Rings, cost
2 transportation of water and emptying pipe line after completion of field testing etc., complete. (for a maximum depth of 4 Mtrs
below GL)
350 MM MAT- 278 MAT- 278 MAT- 278 MAT- 278 MAT- 278 MAT- 278
Meter 06191 06210 06229 06248 06267 06286
DIA.
400 MM Meter MAT- 300 MAT- 300 MAT- 300 MAT- 300 MAT- 300 MAT- 300

45
DIA. 06192 06211 06230 06249 06268 06287
450 MM Meter MAT- 347 MAT- 347 MAT- 347 MAT- 347 MAT- 347 MAT- 347
DIA. 06193 06212 06231 06250 06269 06288
500 MM Meter MAT- 369 MAT- 369 MAT- 369 MAT- 369 MAT- 369 MAT- 369
DIA. 06194 06213 06232 06251 06270 06289
600 MM Meter MAT- 454 MAT- 454 MAT- 454 MAT- 454 MAT- 454 MAT- 454
DIA. 06195 06214 06233 06252 06271 06290
700 MM Meter MAT- 530 MAT- 530 MAT- 530 MAT- 530 MAT- 530 MAT- 530
DIA. 06196 06215 06234 06253 06272 06291
800 MM Meter MAT- 601 MAT- 601 MAT- 601 MAT- 601 MAT- 601 MAT- 601
DIA. 06197 06216 06235 06254 06273 06292
900 MM Meter MAT- 657 MAT- 657 MAT- 657 MAT- 657 MAT- 657 MAT- 657
DIA. 06198 06217 06236 06255 06274 06293
1000 Meter MAT- 759 MAT- 759 MAT- 759 MAT- 759 MAT- 759 MAT- 759
MM IA 06199 06218 06237 06256 06275 06294
1100 Meter MAT- 854 MAT- 854 MAT- 854 MAT- 854 MAT- 854 MAT- 854
MM IA 06200 06219 06238 06257 06276 06295
1200 Meter MAT- 945 MAT- 945 MAT- 945 MAT- 945 MAT- 945 MAT- 945
MMDIA. 06201 06220 06239 06258 06277 06296
1300 Meter MAT- 1072 MAT- 1072 MAT- 1072 MAT- 1072 MAT- 1072 MAT- 1072
MM 06202 06221 06240 06259 06278 06297
DIA.
1400 Meter MAT- 1213 MAT- 1213 MAT- 1213 MAT- 1213 MAT- 1213 MAT- 1213
MM 06203 06222 06241 06260 06279 06298
DIA.
1500 Meter MAT- 1316 MAT- 1316 MAT- 1316 MAT- 1316 MAT- 1316 MAT- 1316
MM 06204 06223 06242 06261 06280 06299
DIA.
1600 Meter MAT- 1474 MAT- 1474 MAT- 1474 MAT- 1474 MAT- 1474 MAT- 1474
MM 06205 06224 06243 06262 06281 06300
DIA.
1700 Meter MAT- 1604 MAT- 1604 MAT- 1604 MAT- 1604 MAT- 1604 MAT- 1604

46
MM 06206 06225 06244 06263 06282 06301
DIA.
1800 Meter MAT- 1697 MAT- 1697 MAT- 1697 MAT- 1697 MAT- 1697 MAT- 1697
MM 06207 06226 06245 06264 06283 06302
DIA.
1900 Meter MAT- 1791 MAT- 1791 MAT- 1791 MAT- 1791 MAT- 1791 MAT- 1791
MM 06208 06227 06246 06265 06284 06303
DIA.
2000 Meter MAT- 1888 MAT- 1888 MAT- 1888 MAT- 1888 MAT- 1888 MAT- 1888
MM 06209 06228 06247 06266 06285 06304
DIA.
Conveyance of Pre-stressed (Non Cylinder) Concrete Pipes and accessories including loading at Factory, unloading at site and
3 stacking for the following sizes: (Minimum distance of 100 Kms to be considered, if the distance is less by 100 Kms from Factory
to Site)
350 MM Per 1.89 1.89 1.89 1.89 1.89 1.89
DIA. K.M/M
400 MM Per 1.89 1.89 1.89 1.89 1.89 1.89
DIA. K.M/M
450 MM Per 2.21 2.21 2.21 2.21 2.21 2.21
DIA. K.M/M
500 MM Per 2.31 2.31 2.31 2.31 2.31 2.31
DIA. K.M/M
600 MM Per 2.63 2.63 2.63 2.63 2.63 2.63
DIA. K.M/M
700 MM Per 4.31 4.31 4.31 4.31 4.31 4.31
DIA. K.M/M
800 MM Per 4.31 4.31 4.31 4.31 4.31 4.31
DIA. K.M/M
Per 4.31 4.31 4.31 4.31 4.31 4.31
900 MM K.M/M

47
DIA.
1000 Per 6.93 6.93 6.93 6.93 6.93 6.93
MM K.M/M
DIA.
1100 Per 6.93 6.93 6.93 6.93 6.93 6.93
MM K.M/M
DIA.
1200 Per 13.23 13.23 13.23 13.23 13.23 13.23
MM K.M/M
DIA.
1300 Per 13.44 13.44 13.44 13.44 13.44 13.44
MM K.M/M
DIA.
1400 Per 13.44 13.44 13.44 13.44 13.44 13.44
MM K.M/M
DIA.
1500 Per 13.44 13.44 13.44 13.44 13.44 13.44
MM K.M/M
DIA.
1600 Per 15.02 15.02 15.02 15.02 15.02 15.02
MM K.M/M
DIA.
1700 Per 15.02 15.02 15.02 15.02 15.02 15.02
MM K.M/M
DIA.
1800 Per 15.33 15.33 15.33 15.33 15.33 15.33
MM K.M/M
DIA.

48
1900 Per 16.07 16.07 16.07 16.07 16.07 16.07
MM K.M/M
DIA.
2000 Per 16.07 16.07 16.07 16.07 16.07 16.07
MM K.M/M
DIA.
Cost of Machine end pair with 100 mm width MS Barrel on each side of Socket and Spigot for providing MS Specials on PSC
4
Pipelines excluding Cost of MS Barrel / Special including cost and conveyance to site etc., complete. Excluding Taxes.
350 MM Per MAT- 11,300 MAT- 11,300 MAT- 11,300 MAT- 11,300 MAT- 11,300 MAT- 11,300
06305 06315 06334 06353 06372 06391
DIA. Pair
400 MM Per MAT- 12,900 MAT- 12,900 MAT- 12,900 MAT- 12,900 MAT- 12,900 MAT- 12,900
06306 06316 06335 06354 06373 06392
DIA. Pair
450 MM Per MAT- 14,600 MAT- 14,600 MAT- 14,600 MAT- 14,600 MAT- 14,600 MAT- 14,600
06307 06317 06336 06355 06374 06393
DIA. Pair
500 MM Per MAT- 16,300 MAT- 16,300 MAT- 16,300 MAT- 16,300 MAT- 16,300 MAT- 16,300
06308 06318 06337 06356 06375 06394
DIA. Pair
600 MM Per MAT- 19,400 MAT- 19,400 MAT- 19,400 MAT- 19,400 MAT- 19,400 MAT- 19,400
06309 06319 06338 06357 06376 06395
DIA. Pair
700 MM Per MAT- 22,700 MAT- 22,700 MAT- 22,700 MAT- 22,700 MAT- 22,700 MAT- 22,700
06310 06320 06339 06358 06377 06396
DIA. Pair
800 MM Per MAT- 26,000 MAT- 26,000 MAT- 26,000 MAT- 26,000 MAT- 26,000 MAT- 26,000
06311 06321 06340 06359 06378 06397
DIA. Pair
900 MM Per MAT- 29,500 MAT- 29,500 MAT- 29,500 MAT- 29,500 MAT- 29,500 MAT- 29,500
06312 06322 06341 06360 06379 06398
DIA. Pair
1000 Per MAT- 31,900 MAT- 31,900 MAT- 31,900 MAT- 31,900 MAT- 31,900 MAT- 31,900
06313 06323 06342 06361 06380 06399
MM Pair
DIA.
Per MAT- 35,300 MAT- 35,300 MAT- 35,300 MAT- 35,300 MAT- 35,300 MAT- 35,300
1100 06314 06324 06343 06362 06381 06400

49
MM Pair
DIA.
1200 Per 38,500 MAT- 38,500 MAT- 38,500 MAT- 38,500 MAT- 38,500 MAT- 38,500
06325 06344 06363 06382 06401
MM Pair
DIA.
1300 Per 41,600 MAT- 41,600 MAT- 41,600 MAT- 41,600 MAT- 41,600 MAT- 41,600
06326 06345 06364 06383 06402
MM Pair
DIA.
1400 Per 49,500 MAT- 49,500 MAT- 49,500 MAT- 49,500 MAT- 49,500 MAT- 49,500
06327 06346 06365 06384 06403
MM Pair
DIA.
1500 Per 58,400 MAT- 58,400 MAT- 58,400 MAT- 58,400 MAT- 58,400 MAT- 58,400
06328 06347 06366 06385 06404
MM Pair
DIA.
1600 Per 65,300 MAT- 65,300 MAT- 65,300 MAT- 65,300 MAT- 65,300 MAT- 65,300
06329 06348 06367 06386 06405
MM Pair
DIA.
1700 Per 73,500 MAT- 73,500 MAT- 73,500 MAT- 73,500 MAT- 73,500 MAT- 73,500
MM 06330 06349 06368 06387 06406
Pair
DIA.
1800 Per 84,300 MAT- 84,300 MAT- 84,300 MAT- 84,300 MAT- 84,300 MAT- 84,300
06331 06350 06369 06388 06407
MM Pair
DIA.
1900 Per 97,800 MAT- 97,800 MAT- 97,800 MAT- 97,800 MAT- 97,800 MAT- 97,800
06332 06351 06370 06389 06408
MM Pair
DIA.
2000 Per 1,14,500 MAT- 1,14,500 MAT- 1,14,500 MAT- 1,14,500 MAT- 1,14,500 MAT- 1,14,500
MM 06333 06352 06371 06390 06409
Pair
DIA.

50
Cost of MS Flanges including cost of Bolts, Nuts, Rubber Packing etc., complete and flange thickness confirming to IS:7322 -
5 1985 and flange dimensions confirming to IS:1538-1993 excluding Cost of MS Special including cost and conveyance to site,
excluding Taxes etc., complete. (Rate per each Flange).
Diameter and Unit Code Rate Diameter and Unit Code Rate
thickness thickness
80 mm dia. x 15 Each Flange MAT- 810 500mm dia. x 20 mm Each Flange MAT-06420 8,270
06410
mm thick Thick
100 mm dia. x 15 Each Flange MAT- 1,110 600 mm dia. x 20 mm Each Flange MAT-06421 10,410
06411
mm thick thick
125 mm dia. x 15 Each Flange MAT- 1,340 700 mm dia. x 25 mm Each Flange MAT-06422 14,700
06412
mm thick thick
150 mm dia. x 15 Each Flange MAT- 1,780 750 mm dia. x 25 mm Each Flange MAT-06423 16,160
06413
mm thick thick
200 mm dia. x 15 Each Flange MAT- 2,230 800 mm dia. x 25 mm Each Flange MAT-06424 18,100
06414
mm thick thick
250 mm dia. x 15 Each Flange MAT- 2,900 900 mm dia. x 25 mm Each Flange MAT-06425 20,790
06415
mm thick thick
300 mm dia. x 15 Each Flange MAT- 3,300 1000 mm dia. x 25 Each Flange MAT-06426 24,500
06416
mm thick mm thick
350 mm dia. x 18 Each Flange MAT- 4,790 1050 mm dia. x 25 Each Flange MAT-06427 26,020
06417
mm thick mm thick
400 mm dia. x 18 Each Flange MAT- 5,980 1100 mm dia. x 25 Each Flange MAT-06428 28,060
06418
mm thick mm thick
450 mm dia. x 18 Each Flange MAT- 6,950 1200 mm dia. x 32 Each Flange MAT-06429 37,170
06419
mm thick mm thick

51
Note:
a) The above rates are Excluding GST. At present prevailing GST rate is @ 18.00% on supply of PSC pipes. Transportation charges extra.

b) The above rates are considering


(A) Landed price of HT Wire (Basic + Freight) @ Rs.60,500/- per MT (4 mm).
(B) Landed price of Cement (Basic + Freight) @ Rs.3672/- per MT.
c) The above prices are subject to Price Variation clause. Revised rate = (R1 + R2), where R1 = Variation (increase / decrease) in cost (Rs.per
Mtr) due to change in the cost of HT Wire which is = (H2 - H1) / 1000 x Wh. R2 = Variation (increase / decrease) in cost (Rs.per Mtr) due to
change in the cost of Cement which is = (C2 - C1) / 1000 x Wc. ****** H1 = Rs.60,500/- per MT (4 mm) / H2 = Cost of HT Wire at the time of
preparation of estimate, C1 = Rs.3,672/- per MT, C2 = Cost of Cement at the time of preparation of estimate, Wh = Weight of HT wire required
(Kg per Mtr) Wc = Weight of Cement required (Kg per Mtr).

d) The above rates for MS Flanges are considering landed price of MS Plates as Rs.55,000/- per MT.

52
12. S o R FOR PRE-STRESSED (CYLINDER) CONCRETE PIPES FOR THE YEAR 2021-22

S.
Description
No.

Manufacture, Supply, Delivery of BIS MARKED PRE-STRESSED (CYLINDER TYPE) CONCRETE PIPES as per IS: 784-2001 @ Ex-factory cost of pipes excluding
1 Transportation, Laying, Jointing, Testing, Bends, Tees, Specials, taxes and duties etc., for following Field / Line / Site test pressures:
Size Unit SoR For 2021-22
4 6 8 10 12 14 16 18 20
Code Code Code Code Code Code Code Code Code
Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2
400 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06430 5880 06448 5880 06466 5880 06484 5880 06502 5908 06520 5969 06538 6071 06556 6170 06574 6244
DIA.
450 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06431 6391 06449 6391 06467 6391 06485 6420 06503 6494 06521 6584 06539 6693 06557 6740 06575 6799
DIA.
500 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06432 6820 06450 6820 06468 6886 06486 6946 06504 7005 06522 7084 06540 7178 06558 7249 06576 7320
DIA.
600 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06433 7831 06451 7911 06469 7994 06487 8086 06505 8168 06523 8250 06541 8390 06559 8496 06577 8591
DIA.
700 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06434 8906 06452 9011 06470 9129 06488 9235 06506 9351 06524 9457 06542 9652 06560 9773 06578 9924
DIA.
800 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06435 10481 06453 10610 06471 10751 06489 10903 06507 11045 06525 11186 06543 11395 06561 11593 06579 11760
DIA.
900 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06436 11926 06454 12112 06472 12288 06490 12475 06508 12663 06526 12850 06544 13338 06562 13585 06580 13874
DIA.
1000 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06437 14306 06455 14529 06473 14754 06491 14987 06509 15209 06527 15443 06545 16087 06563 16414 06581 16739
DIA.
1100 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06438 15902 06456 16171 06474 16452 06492 16722 06510 17004 06528 17273 06546 18062 06564 18424 06582 18855
DIA.
1200 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06439 17687 06457 18015 06475 18332 06493 18660 06511 19000 06529 19326 06547 20263 06565 20727 06583 21188
DIA.
1300 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06440 19779 06458 20165 06476 20551 06494 20938 06512 21326 06530 22051 06548 22843 06566 23409 06584 24028
DIA.
1400 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
Meter 22160 22639 23127 23661 24602 25227 26119 26381 27442
MM 06441 06459 06477 06495 06513 06531 06549 06567 06585

53
DIA.
1500 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06442 26030 06460 26615 06478 27119 06496 27635 06514 28645 06532 29219 06550 29989 06568 31155 06586 31797
DIA.
1600 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06443 29354 06461 30143 06479 30811 06497 31891 06515 32549 06533 33271 06551 34594 06569 35321 06587 36047
DIA.
1700 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06444 31595 06462 32459 06480 33118 06498 34350 06516 35089 06534 36638 06552 37487 06570 38317 06588 39156
DIA.
1800 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06445 34564 06463 35523 06481 37399 06499 38563 06517 39702 06535 41837 06553 43646 06571 44576 06589 45526
DIA.
1900 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM Meter 06446 40151 06464 40980 06482 42439 06500 43338 06518 45173 06536 46201 06554 47264 06572 48305 06590 49346
DIA.
2000 MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06447 06465 06483 06501 06519 06537 06555 06573 06591
Meter 42366 43888 44896 45918 47964 49097 50281 51433 52598
DIA.

2
Cost of laying jointing, testing to Hydrostatic field test pressure including cost of site welding and fixing of Polypropylene Diapher cloth, cost transportation of water and
emptying pipe line after completion of field testing.
400 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 573 06610 573 06628 573 06646 573 06664 573 06682 573 06700 573 06718 573 06736 573
DIA.
06592
450 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 674 06611 674 06629 674 06647 674 06665 674 06683 674 06701 674 06719 674 06737 674
DIA.
06593
500 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 734 06612 734 06630 734 06648 734 06666 734 06684 734 06702 734 06720 734 06738 734
DIA.
06594
600 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 859 06613 859 06631 859 06649 859 06667 859 06685 859 06703 859 06721 859 06739 859
DIA.
06595
700 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 978 06614 978 06632 978 06650 978 06668 978 06686 978 06704 978 06722 978 06740 978
DIA.
06596
800 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 1124 06615 1124 06633 1124 06651 1124 06669 1124 06687 1124 06705 1124 06723 1124 06741 1124
DIA.
06597
900 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 1266 06616 1266 06634 1266 06652 1266 06670 1266 06688 1266 06706 1266 06724 1266 06742 1266
DIA.
06598
1000 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM
06599 1387 06617 1387 06635 1387 06653 1387 06671 1387 06689 1387 06707 1387 06725 1387 06743 1387
DIA.

54
1100 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06600 1573 06618 1573 06636 1573 06654 1573 06672 1573 06690 1573 06708 1573 06726 1573 06744 1573
DIA.
1200 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06601 1716 06619 1716 06637 1716 06655 1716 06673 1716 06691 1716 06709 1716 06727 1716 06745 1716
DIA.
1300 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06602 1836 06620 1836 06638 1836 06656 1836 06674 1836 06692 1836 06710 1836 06728 1836 06746 1836
DIA.
1400 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06603 2021 06621 2021 06639 2021 06657 2021 06675 2021 06693 2021 06711 2021 06729 2021 06747 2021
DIA.
1500 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06604 2244 06622 2244 06640 2244 06658 2244 06676 2244 06694 2244 06712 2244 06730 2244 06748 2244
DIA.
1600 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06605 2429 06623 2429 06641 2429 06659 2429 06677 2429 06695 2429 06713 2429 06731 2429 06749 2429
DIA.
1700 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06606 2735 06624 2735 06642 2735 06660 2735 06678 2735 06696 2735 06714 2735 06732 2735 06750 2735
DIA.
1800 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06607 2900 06625 2900 06643 2900 06661 2900 06679 2900 06697 2900 06715 2900 06733 2900 06751 2900
DIA.
1900 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06608 3163 06626 3163 06644 3163 06662 3163 06680 3163 06698 3163 06716 3163 06734 3163 06752 3163
DIA.
2000 Meter MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT- MAT-
MM 06609 3367 06627 3367 06645 3367 06663 3367 06681 3367 06699 3367 06717 3367 06735 3367 06753 3367
DIA.
Conveyance of Pre-stressed (Non Cylinder) Concrete Pipes and accessories including loading at Factory, unloading at site and stacking for the following sizes: (Minimum
3
distance of 100 Kms to be considered, if the distance is less by 100 Kms from Factory to Site).
400 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58
Per
MM
KM/M
DIA.
450 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58 1.58
Per
MM
KM/M
DIA.
500 2.21 2.21 2.21 2.21 2.21 2.21 2.21 2.21 2.21
Per
MM
KM/M
DIA.
600 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52 2.52
Per
MM
KM/M
DIA.
700 Per 3.99 3.99 3.99 3.99 3.99 3.99 3.99 3.99 3.99
MM KM/M

55
DIA.
800 3.99 3.99 3.99 3.99 3.99 3.99 3.99 3.99 3.99
Per
MM
KM/M
DIA.
900 3.99 3.99 3.99 3.99 3.99 3.99 3.99 3.99 3.99
Per
MM
KM/M
DIA.
1000 6.30 6.30 6.30 6.30 6.30 6.30 6.30 6.30 6.30
Per
MM
KM/M
DIA.
1100 6.30 6.30 6.30 6.30 6.30 6.30 6.30 6.30 6.30
Per
MM
KM/M
DIA.
1200 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50
Per
MM
KM/M
DIA.
1300 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50
Per
MM
KM/M
DIA.
1400 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50
Per
MM
KM/M
DIA.
1500 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50
Per
MM
KM/M
DIA.
1600 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50 12.50
Per
MM
KM/M
DIA.
1700 15.02 15.02 15.02 15.02 15.02 15.02 15.02 15.02 15.02
Per
MM
KM/M
DIA.
1800 15.02 15.02 15.02 15.02 15.02 15.02 15.02 15.02 15.02
Per
MM
KM/M
DIA.
1900 15.02 15.02 15.02 15.02 15.02 15.02 15.02 15.02 15.02
Per
MM
KM/M
DIA.
2000 15.96 15.96 15.96 15.96 15.96 15.96 15.96 15.96 15.96
Per
MM
KM/M
DIA.

56
Note:
a) The above rates are Excluding GST. At present prevailing GST rate is @ 18.00% on supply of PCC pipes. Transportation charges extra.

b) The above rates are considering


(A) Landed price of HT Wire (Basic + Freight) @ Rs.60,500/- per MT (4 mm).
(B) Landed price of Cement (Basic + Freight) @ Rs.3,672/- per MT and
(C) Landed price of HR Plates (Basic + Freight) @ Rs.59,000/- per MT (1.60 mm) and Rs.57,000/- per MT (2.00 - 4.00 mm).

c) The above prices for PCCP pipes are subject to Price Variation clause. Revised rate = (R1 + R2 + R3), where R1 = Variation (increase /
decrease) in cost (Rs.per Mtr) due to change in the cost of HT Wire which is = (H2 - H1) / 1000 x Wh. R2 = Variation (increase / decrease) in
cost (Rs.per Mtr) due to change in the cost of HR Plate / COil which is = (R2 - R1) / 1000 x Wr. R3 = Variation (increase / decrease) in cost
(Rs.per Mtr) due to change in the cost of Cement which is = (C2 - C1) / 1000 x Wc. ****** H1 = Rs.60,500/- per MT (4 mm) / H2 = Cost of HT
Wire at the time of preparation of estimate, R1 = Rs.59,000/- per MT (1.60 mm) & Rs.57,000/- per MT (2.00 - 4.00 mm) / R2 = Cost of HR
Coils / Plates at the time of preparation of estimate, C1 = Rs.3,672/- per MT, C2 = Cost of Cement at the time of preparation of estimate, Wh =
Weight of HT wire required (Kg per Mtr), Wr = Weight of HR Plate / Coils required (Kg per Mtr) & Wc = Weight of Cement required (Kg per
Mtr).

57
Public Health Items
13. S o R FOR BAR WRAPPED STEEL CYLINDRICAL (BWSC) PIPES FOR THE YEAR 2021-22
Sl.No. Description

BAR WRAPPED STEEL CYLINDRICAL (BWSC) PIPES (BIS MARKED) AS PER IS: 15155-2002 @ Ex-factory cost of pipes including Bends as per IS:7322
1 excluding Transportation, Laying, Jointing, Testing, Tees, Specials, taxes and duties etc., for following Field / Line / Site test pressures of Bar Wrapped
Steel Cylindrical Pipes:
4 -12 14 16 20 26 28
18 22 24 30
Size Unit Code Kg/c Code Kg/cm Code Kg/cm Code Code Kg/cm Code Code Code Kg/cm Code Kg/cm Code
Kg/cm2 Kg/cm2 Kg/cm2 Kg/cm2
m2 2 2 2 2 2

MAT- 2892 MAT 2892 MAT- 2892 MAT- 2892 MAT- 2892 MAT- 2892 MAT- 3204 MAT- 3308 MAT 3346 MAT- 3513
250 MM 06754 - 06780 06793 06806 06819 06832 06845 - 06871
Meter
DIA. 06767 0685
8
MAT- 3222 MAT 3222 MAT- 3222 MAT- 3222 MAT- 3222 MAT- 3378 MAT- 3828 MAT- 3973 MAT 4056 MAT- 4264
300 MM 06755 - 06781 06794 06807 06820 06833 06846 - 06872
Meter
DIA. 06768 0685
9
MAT- 3917 MAT 3917 MAT- 3917 MAT- 3982 MAT- 4175 MAT- 4384 MAT- 4578 MAT- 4771 MAT 4979 MAT- 5178
350 MM 06756 - 06782 06795 06808 06821 06834 06847 - 06873
Meter
DIA. 06769 0686
0
MAT- 4314 MAT 4314 MAT- 4405 MAT- 4666 MAT- 4911 MAT- 5168 MAT- 5414 MAT- 5672 MAT 5924 MAT- 6159
400 MM 06757 - 06783 06796 06809 06822 06835 06848 - 06874
Meter
DIA. 06770 0686
1
MAT- 4827 MAT 4865 MAT- 5201 MAT- 5509 MAT- 5845 MAT- 6098 MAT- 6397 MAT- 6644 MAT 6923 MAT- 7468
450 MM 06758 - 06784 06797 06810 06823 06836 06849 - 06875
Meter
DIA. 06771 0686
2
MAT- 5232 MAT 5595 MAT- 5983 MAT- 6396 MAT- 6760 MAT- 7182 MAT- 7543 MAT- 7857 MAT 8376 MAT- 8892
500 MM 06759 - 06785 06798 06811 06824 06837 06850 - 06876
Meter
DIA. 06772 0686
3
MAT- 6475 MAT 6929 MAT- 7498 MAT- 8040 MAT- 8621 MAT- 9213 MAT- 9866 MAT- 10533 MAT 11170 MAT- 11710
600 MM 06760 - 06786 06799 06812 06825 06838 06851 - 06877
Meter
DIA. 06773 0686
4
MAT- 7866 MAT 8670 MAT- 9407 MAT- 10168 MAT- 11022 MAT- 11850 MAT- 12625 MAT- 13761 MAT 14473 MAT- 15123
700 MM 06761 - 06787 06800 06813 06826 06839 06852 - 06878
Meter
DIA. 06774 0686
5
MAT- 9436 MAT 10533 MAT- 11501 MAT- 12533 MAT- 13725 MAT- 14737 MAT- 16044 MAT- 17035 MAT 18003 MAT- 19059
800 MM 06762 - 06788 06801 06814 06827 06840 06853 - 06879
Meter
DIA. 06775 0686
6
MAT- 1141 MAT 12690 MAT- 13890 MAT- 15206 MAT- 16510 MAT- 18095 MAT- 19358 MAT- 20676 MAT 22171 MAT- 23699
900 MM 06763 1 - 06789 06802 06815 06828 06841 06854 - 06880
Meter
DIA. 06776 0686
7

58
Public Health Items
MAT- 1348 MAT 15082 MAT- 16818 MAT- 18417 MAT- 19920 MAT- 21429 MAT- 23019 MAT- 24815 MAT 26988 MAT- 28482
1000 MM 06764 5 - 06790 06803 06816 06829 06842 06855 - 06881
Meter
DIA. 06777 0686
8
MAT- 1776 MAT 18149 MAT- 19929 MAT- 21914 MAT- 23835 MAT- 25717 MAT- 28136 MAT- 29810 MAT 32126 MAT- 34193
1100 MM 06765 2 - 06791 06804 06817 06830 06843 06856 - 06882
Meter
DIA. 06778 0686
9
MAT- 1937 MAT 20730 MAT- 22884 MAT- 25136 MAT- 27416 MAT- 29736 MAT- 32536 MAT- 35279 MAT 37792 MAT- 39900
1200 MM 06766 8 - 06792 06805 06818 06831 06844 06857 - 06883
Meter
DIA. 06779 0687
0
Cost of laying jointing, testing to Hydrostatic field test pressure including cost of site welding and fixing of Polypropylene Diapher cloth, cost transportation of water
2
and emptying pipe line after completion of field testing.
MAT- 391 MAT 391 MAT- 391 MAT 391 MAT 391 MAT 391 MAT 391 MAT- 391 MAT 391 MAT- 391
250 MM 06884 - 06910 - - - - 06975 - 07001
Meter
DIA. 0689 0692 0693 0694 0696 0698
7 3 6 9 2 8
MAT- 460 MAT 460 MAT- 460 MAT 460 MAT 460 MAT- 460 MAT 460 MAT- 460 MAT 460 MAT- 460
300 MM 06885 - 06911 - - 06950 - 06976 - 07002
Meter
DIA. 06898 06924 0693 0696 0698
7 3 9
MAT- 543 MAT 543 MAT- 543 MAT 543 MAT 543 MAT- 543 MAT 543 MAT- 543 MAT 543 MAT- 543
350 MM 06886 - 06912 - - 06951 - 06977 - 07003
Meter
DIA. 06899 06925 0693 0696 0699
8 4 0
MAT- 608 MAT 608 MAT- 608 MAT 608 MAT 608 MAT- 608 MAT 608 MAT- 608 MAT 608 MAT- 608
400 MM 06887 - 06913 - - 06952 - 06978 - 07004
Meter
DIA. 06900 06926 0693 0696 0699
9 5 1
MAT- 608 MAT 608 MAT- 608 MAT 608 MAT 608 MAT- 608 MAT 608 MAT- 608 MAT 608 MAT- 608
450 MM 06888 - 06914 - - 06953 - 06979 - 07005
Meter
DIA. 06901 06927 0694 0696 0699
0 6 2
MAT- 761 MAT 761 MAT- 761 MAT 761 MAT 761 MAT- 761 MAT 761 MAT- 761 MAT 761 MAT- 761
500 MM 06889 - 06915 - - 06954 - 06980 - 07006
Meter
DIA. 06902 06928 0694 0696 0699
1 7 3
MAT- 936 MAT 936 MAT- 936 MAT 936 MAT 936 MAT- 936 MAT 936 MAT- 936 MAT 936 MAT- 936
600 MM 06890 - 06916 - - 06955 - 06981 - 07007
Meter
DIA. 06903 06929 0694 0696 0699
2 8 4
MAT- 1090 MAT 1090 MAT- 1090 MAT 1090 MAT 1090 MAT- 1090 MAT 1090 MAT- 1090 MAT 1090 MAT- 1090
700 MM 06891 - 06917 - - 06956 - 06982 - 07008
Meter
DIA. 06904 06930 0694 0696 0699
3 9 5
MAT- 1240 MAT 1240 MAT- 1240 MAT 1240 MAT 1240 MAT- 1240 MAT 1240 MAT- 1240 MAT 1240 MAT- 1240
800 MM 06892 - 06918 - - 06957 - 06983 - 07009
Meter
DIA. 06905 06931 0694 0697 0699
4 0 6

59
Public Health Items
MAT- 1457 MAT 1457 MAT- 1457 MAT 1457 MAT 1457 MAT- 1457 MAT 1457 MAT- 1457 MAT 1457 MAT- 1457
900 MM 06893 - 06919 - - 06958 - 06984 - 07010
Meter
DIA. 06906 06932 0694 0697 0699
5 1 7
MAT- 1611 MAT 1611 MAT- 1611 MAT 1611 MAT 1611 MAT- 1611 MAT 1611 MAT- 1611 MAT 1611 MAT- 1611
1000 MM 06894 - 06920 - - 06959 - 06985 - 07011
Meter
DIA. 06907 06933 0694 0697 0699
6 2 8
MAT- 1893 MAT 1893 MAT- 1893 MAT 1893 MAT 1893 MAT- 1893 MAT 1893 MAT- 1893 MAT 1893 MAT- 1893
1100 MM 06895 - 06921 - - 06960 - 06986 - 07012
Meter
DIA. 06908 06934 0694 0697 0699
7 3 9
MAT- 2119 MAT 2119 MAT- 2119 MAT 2119 MAT 2119 MAT- 2119 MAT 2119 MAT- 2119 MAT 2119 MAT- 2119
1200 MM 06896 - 06922 - - 06961 - 06987 - 07013
Meter
DIA. 06909 06935 0694 0697 0700
8 4 0
Conveyance of Bar Wrapped steel Cylindrical (BWSC) pipes and accessories including loading at Factory, unloading at site and stacking for the
3 following sizes: (Minimum distance of 100 Kms to be considered, if the distance is less by 100 Kms from Factory to Site)
250 MM Per 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83
DIA. KM/M
300 MM Per 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83 0.83
DIA. KM/M
350 MM Per 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10 1.10
DIA. KM/M
400 MM Per 1.38 1.38 1.38 1.38 1.38 1.38 1.38 1.38 1.38 1.38
DIA. KM/M
450 MM Per 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81 1.81
DIA. KM/M
500 MM Per 2.22 2.22 2.22 2.22 2.22 2.22 2.22 2.22 2.22 2.22
DIA. KM/M
600 MM Per 2.35 2.35 2.35 2.35 2.35 2.35 2.35 2.35 2.35 2.35
DIA. KM/M
700 MM Per 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64 2.64
DIA. KM/M
800 MM Per 3.47 3.47 3.47 3.47 3.47 3.47 3.47 3.47 3.47 3.47
DIA. KM/M
900 MM Per 3.73 3.73 3.73 3.73 3.73 3.73 3.73 3.73 3.73 3.73
DIA. KM/M
1000 MM Per 4.28 4.28 4.28 4.28 4.28 4.28 4.28 4.28 4.28 4.28
DIA. KM/M
1100 MM Per 9.56 9.56 9.56 9.56 9.56 9.56 9.56 9.56 9.56 9.56
DIA. KM/M
1200 MM Per 13.37 13.37 13.37 13.37 13.37 13.37 13.37 13.37 13.37 13.37
DIA. KM/M

Note:
a) The above rates are Excluding GST. Transportation charges extra.

60
Public Health Items
b) The above rates are considering
(A) Landed price of HR Plates (Basic + Freight) @ Rs.59,000/- per MT (1.60 mm) & Rs.57,000/- per MT (2.00-4.00 mm).
(B) Landed price of Cement (Basic + Freight) @ Rs.3672/- per MT and
(C) Landed price of MS Wire Rods at Hyderabad (Basic + Freight) @ Rs.49500/- per MT. All above rates of raw materials
are excluding GST.
c) The above prices for BWSC pipes are subject to Price Variation clause. Revised rate = (R1 + R2 + R3), where R1 = Variation
(increase / decrease) in cost (Rs.per Mtr) due to change in the cost of HR Plate / Coil which is = (H2 - H1) / 1000 x Wh. R2 =
Variation (increase / decrease) in cost (Rs.per Mtr) due to change in the cost of Wire Rods which is = (W2 - W1) / 1000 x Ww. R3 =
Variation (increase / decrease) in cost (Rs.per Mtr) due to change in the cost of Cement which is = (C2 - C1) / 1000 x Wc. ****** H1
= Rs.59,000/- per MT (1.60 mm) & Rs.57,000/- per MT (2.00 -4.00 mm) / H2 = Cost of HR Plate / Coil at the time of preparation of
estimate, W1 = Rs.49500/- per MT / W2 = Cost of Wire Rods at the time of preparation of estimate, C1 = Rs.3672/- per MT, C2 =
Cost of Cement at the time of preparation of estimate, Wh = Weight of HR Plate / Coil required (Kg per Mtr), Ww = Weight of Wire
Rods required (Kg per Mtr) & Wc = Weight of Cement required (Kg per Mtr).
d) The duties and taxes as applicable may be added as per rules at the time of preparation of estimates.

61
Public Health Engineering Items

14. S o R FOR M.S. PIPES FOR THE YEAR 2021-22

Thicknes
Sl.No. Description Unit Code Rate
s in mm
1 Manufacture, supply and delivery of M.S Spirally Welded Pipes conforming to IS:
3589/2001 including in lining with cement mortar (1:2) 15mm thick using 4 numbers
of 6mm dia. M.S. Rings at each end of the pipe and out coating with cement mortar
(1:3) 30mm thick by short crating or guniting duly providing wire mesh of size
50x50x3mm including cost of all materials, labor charges, transportation to
anywhere in AP, but excluding all taxes.
500 mm dia. Meter 8.00 MAT-07014 8573

600 mm dia. Meter 8.00 MAT-07015 10174

700 mm dia. Meter 8.00 MAT-07016 11853


700 mm dia. Meter 10.00 MAT-07017 15114

800 mm dia. Meter 8.00 MAT-07018 13591


800 mm dia. Meter 10.00 MAT-07019 16144
800 mm dia. Meter 12.00 MAT-07020 19491

900 mm dia. Meter 8.00 MAT-07021 15163


900 mm dia. Meter 10.00 MAT-07022 18028
900 mm dia. Meter 12.00 MAT-07023 20900

1000 mm dia. Meter 8.00 MAT-07024 17012


1000 mm dia. Meter 10.00 MAT-07025 20182
1000 mm dia. Meter 12.00 MAT-07026 23272
1000 mm dia. Meter 14.00 MAT-07027 27278

1100 mm dia. Meter 8.00 MAT-07028 19587


1100 mm dia. Meter 10.00 MAT-07029 23549
1100 mm dia. Meter 12.00 MAT-07030 27038
1100 mm dia. Meter 14.00 MAT-07031 31683
1100 mm dia. Meter 16.00 MAT-07032 36344

1200 mm dia. Meter 8.00 MAT-07033 21881


1200 mm dia. Meter 10.00 MAT-07034 26450

62
Public Health Engineering Items

1200 mm dia. Meter 12.00 MAT-07035 30271


1200 mm dia. Meter 14.00 MAT-07036 34091
1200 mm dia. Meter 16.00 MAT-07037 39101
1200 mm dia. Meter 18.00 MAT-07038 44126

1300 mm dia. Meter 8.00 MAT-07039 24211


1300 mm dia. Meter 10.00 MAT-07040 28532
1300 mm dia. Meter 12.00 MAT-07041 32958
1300 mm dia. Meter 14.00 MAT-07042 37082
1300 MM DIA. Meter 16.00 MAT-07043 41221
1300 MM DIA. Meter 18.00 MAT-07044 46518
1300 MM DIA. Meter 20.00 MAT-07045 51830

1400 MM DIA. Meter 8.00 MAT-07046 26000


1400 MM DIA. Meter 10.00 MAT-07047 30639
1400 MM DIA. Meter 12.00 MAT-07048 35146
1400 MM DIA. Meter 14.00 MAT-07049 39583
1400 MM DIA. Meter 16.00 MAT-07050 44030
1400 MM DIA. Meter 18.00 MAT-07051 49684
1400 MM DIA. Meter 20.00 MAT-07052 55350
1400 MM DIA. Meter 22.00 MAT-07053 61033

1500 MM DIA. Meter 8.00 MAT-07054 27800


1500 MM DIA. Meter 10.00 MAT-07055 32763
1500 MM DIA. Meter 12.00 MAT-07056 37614
1500 MM DIA. Meter 14.00 MAT-07057 42356
1500 MM DIA. Meter 16.00 MAT-07058 47116
1500 MM DIA. Meter 18.00 MAT-07059 51880
1500 MM DIA. Meter 20.00 MAT-07060 57795
1500 MM DIA. Meter 22.00 MAT-07061 63726
1500 MM DIA. Meter 24.00 MAT-07062 69671

1600 MM DIA. Meter 8.00 MAT-07063 29638


1600 MM DIA. Meter 10.00 MAT-07064 34761
1600 MM DIA. Meter 12.00 MAT-07065 39802
1600 MM DIA. Meter 14.00 MAT-07066 44856

63
Public Health Engineering Items

1600 MM DIA. Meter 16.00 MAT-07067 49922


1600 MM DIA. Meter 18.00 MAT-07068 54999
1600 MM DIA. Meter 20.00 MAT-07069 61265
1600 MM DIA. Meter 22.00 MAT-07070 67547
1600 MM DIA. Meter 24.00 MAT-07071 73843
1600 MM DIA. Meter 26.00 MAT-07072 80152

1700 MM DIA. Meter 8.00 MAT-07073 31355


1700 MM DIA. Meter 10.00 MAT-07074 36916
1700 MM DIA. Meter 12.00 MAT-07075 42266
1700 MM DIA. Meter 14.00 MAT-07076 47631
1700 MM DIA. Meter 16.00 MAT-07077 53003
1700 MM DIA. Meter 18.00 MAT-07078 58391
1700 MM DIA. Meter 20.00 MAT-07079 65039
1700 MM DIA. Meter 22.00 MAT-07080 71706
1700 MM DIA. Meter 24.00 MAT-07081 78380
1700 MM DIA. Meter 26.00 MAT-07082 85078
1700 MM DIA. Meter 28.00 MAT-07083 91786

1800 MM DIA. Meter 8.00 MAT-07084 33219


1800 MM DIA. Meter 10.00 MAT-07085 39072
1800 MM DIA. Meter 12.00 MAT-07086 44732
1800 MM DIA. Meter 14.00 MAT-07087 50408
1800 MM DIA. Meter 16.00 MAT-07088 56086
1800 MM DIA. Meter 18.00 MAT-07089 61787
1800 MM DIA. Meter 20.00 MAT-07090 67495
1800 MM DIA. Meter 22.00 MAT-07091 74407
1800 MM DIA. Meter 24.00 MAT-07092 81335
1800 MM DIA. Meter 26.00 MAT-07093 88274
1800 MM DIA. Meter 28.00 MAT-07094 95231
1800 MM DIA. Meter 30.00 MAT-07095 102200

1900 MM DIA. Meter 8.00 MAT-07096 33965


1900 MM DIA. Meter 10.00 MAT-07097 40952
1900 MM DIA. Meter 12.00 MAT-07098 46918
1900 MM DIA. Meter 14.00 MAT-07099 52900

64
Public Health Engineering Items

1900 MM DIA. Meter 16.00 MAT-07100 58893


1900 MM DIA. Meter 18.00 MAT-07101 64904
1900 MM DIA. Meter 20.00 MAT-07102 70918
1900 MM DIA. Meter 22.00 MAT-07103 78176
1900 MM DIA. Meter 24.00 MAT-07104 85449
1900 MM DIA. Meter 26.00 MAT-07105 92740
1900 MM DIA. Meter 28.00 MAT-07106 100042
1900 MM DIA. Meter 30.00 MAT-07107 107362
1900 MM DIA. Meter 32.00 MAT-07108 114692

2000 MM DIA. Meter 8.00 MAT-07109 35526


2000 MM DIA. Meter 10.00 MAT-07110 42835
2000 MM DIA. Meter 12.00 MAT-07111 49110
2000 MM DIA. Meter 14.00 MAT-07112 55402
2000 MM DIA. Meter 16.00 MAT-07113 61705
2000 MM DIA. Meter 18.00 MAT-07114 68023
2000 MM DIA. Meter 20.00 MAT-07115 74345
2000 MM DIA. Meter 22.00 MAT-07116 80644
2000 MM DIA. Meter 24.00 MAT-07117 88144
2000 MM DIA. Meter 26.00 MAT-07118 95657
2000 MM DIA. Meter 28.00 MAT-07119 103188
2000 MM DIA. Meter 30.00 MAT-07120 110729
2000 MM DIA. Meter 32.00 MAT-07121 118287
2000 MM DIA. Meter 34.00 MAT-07122 125858

2100 MM DIA. Meter 8.00 MAT-07123 37316


2100 MM DIA. Meter 10.00 MAT-07124 44989
2100 MM DIA. Meter 12.00 MAT-07125 51576
2100 MM DIA. Meter 14.00 MAT-07126 58162
2100 MM DIA. Meter 16.00 MAT-07127 64786
2100 MM DIA. Meter 18.00 MAT-07128 71410
2100 MM DIA. Meter 20.00 MAT-07129 78047
2100 MM DIA. Meter 22.00 MAT-07130 84699
2100 MM DIA. Meter 24.00 MAT-07131 92573
2100 MM DIA. Meter 26.00 MAT-07132 100460
2100 MM DIA. Meter 28.00 MAT-07133 108362

65
Public Health Engineering Items

2100 MM DIA. Meter 30.00 MAT-07134 116278


2100 MM DIA. Meter 32.00 MAT-07135 124210
2100 MM DIA. Meter 34.00 MAT-07136 132155
2100 MM DIA. Meter 36.00 MAT-07137 140112

2200 MM DIA. Meter 8.00 MAT-07138 38874


2200 MM DIA. Meter 10.00 MAT-07139 46870
2200 MM DIA. Meter 12.00 MAT-07140 53770
2200 MM DIA. Meter 14.00 MAT-07141 60674
2200 MM DIA. Meter 16.00 MAT-07142 67597
2200 MM DIA. Meter 18.00 MAT-07143 74526
2200 MM DIA. Meter 20.00 MAT-07144 81474
2200 MM DIA. Meter 22.00 MAT-07145 88436
2200 MM DIA. Meter 26.00 MAT-07146 104884
2200 MM DIA. Meter 28.00 MAT-07147 113129
2200 MM DIA. Meter 30.00 MAT-07148 121386
2200 MM DIA. Meter 32.00 MAT-07149 129661
2200 MM DIA. Meter 34.00 MAT-07150 137952
2200 MM DIA. Meter 36.00 MAT-07151 146254
2200 MM DIA. Meter 38.00 MAT-07152 154572

2300 MM DIA. Meter 10.00 MAT-07153 44686


2300 MM DIA. Meter 12.00 MAT-07154 56231
2300 MM DIA. Meter 16.00 MAT-07155 69503
2300 MM DIA. Meter 18.00 MAT-07156 77919
2300 MM DIA. Meter 20.00 MAT-07157 85177
2300 MM DIA. Meter 22.00 MAT-07158 92441
2300 MM DIA. Meter 26.00 MAT-07159 107110
2300 MM DIA. Meter 28.00 MAT-07160 115988
2300 MM DIA. Meter 30.00 MAT-07161 124926
2300 MM DIA. Meter 32.00 MAT-07162 134706
2300 MM DIA. Meter 34.00 MAT-07163 142720
2300 MM DIA. Meter 36.00 MAT-07164 151670
2300 MM DIA. Meter 38.00 MAT-07165 160678
2300 MM DIA. Meter 40.00 MAT-07166 169643

66
Public Health Engineering Items

2400MM DIA. Meter 10.00 MAT-07167 50905


2400 MM DIA. Meter 12.00 MAT-07168 58420
2400 MM DIA. Meter 14.00 MAT-07169 66878
2400 MM DIA. Meter 16.00 MAT-07170 74421
2400 MM DIA. Meter 18.00 MAT-07171 81968
2400 MM DIA. Meter 20.00 MAT-07172 89539
2400 MM DIA. Meter 22.00 MAT-07173 97960
2400 MM DIA. Meter 26.00 MAT-07174 107663
2400 MM DIA. Meter 28.00 MAT-07175 115643
2400 MM DIA. Meter 30.00 MAT-07176 123639
2400 MM DIA. Meter 32.00 MAT-07177 131646
2400 MM DIA. Meter 34.00 MAT-07178 139664
2400 MM DIA. Meter 36.00 MAT-07179 147700
2400 MM DIA. Meter 38.00 MAT-07180 155745
2400 MM DIA. Meter 40.00 MAT-07181 157539
2400 MM DIA. Meter 42.00 MAT-07182 165604

2500 MM DIA. Meter 10.00 MAT-07183 53062


2500 MM DIA. Meter 14.00 MAT-07184 68722
2500 MM DIA. Meter 16.00 MAT-07185 76570
2500 MM DIA. Meter 18.00 MAT-07186 84433
2500 MM DIA. Meter 20.00 MAT-07187 92305
2500 MM DIA. Meter 22.00 MAT-07188 100192
2500 MM DIA. Meter 28.00 MAT-07189 128125
2500 MM DIA. Meter 30.00 MAT-07190 137468
2500 MM DIA. Meter 34.00 MAT-07191 151990
2500 MM DIA. Meter 36.00 MAT-07192 161911
2500 MM DIA. Meter 38.00 MAT-07193 171889
2500 MM DIA. Meter 40.00 MAT-07194 181882
2500 MM DIA. Meter 42.00 MAT-07195 191922
2500 MM DIA. Meter 44.00 MAT-07196 201914
2500 MM DIA. Meter 46.00 MAT-07197 211964

2600 MM DIA. Meter 12.00 MAT-07198 57546


2600 MM DIA. Meter 14.00 MAT-07199 71221
2600 MM DIA. Meter 16.00 MAT-07200 79381

67
Public Health Engineering Items

2600 MM DIA. Meter 18.00 MAT-07201 87551


2600 MM DIA. Meter 20.00 MAT-07202 95735
2600 MM DIA. Meter 22.00 MAT-07203 103928
2600 MM DIA. Meter 32.00 MAT-07204 152277
2600 MM DIA. Meter 34.00 MAT-07205 161992
2600 MM DIA. Meter 36.00 MAT-07206 171717
2600 MM DIA. Meter 38.00 MAT-07207 181459
2600 MM DIA. Meter 40.00 MAT-07208 191216
2600 MM DIA. Meter 42.00 MAT-07209 200987
2600 MM DIA. Meter 44.00 MAT-07210 210774
2600 MM DIA. Meter 46.00 MAT-07211 220571
2600 MM DIA. Meter 48.00 MAT-07212 230387
2 Cost of Laying, Jointing, Hydrostatic Filed Test Pressure, Including Cost of Site
Welding, Jointing Materials And Cost of Transportation of Water Including
Emptying Pipe Line After Completion Of Field Testing

400 MM DIA. Meter MAT-07213 716


500 MM DIA. Meter MAT-07214 891
600 MM DIA. Meter MAT-07215 1096
700 MM DIA. Meter MAT-07216 1273
800 MM DIA. Meter MAT-07217 1452
900 MM DIA. Meter MAT-07218 1707
1000 MM DIA. Meter MAT-07219 1885
1100 MM DIA. Meter MAT-07220 2218
1200 MM DIA. Meter MAT-07221 2484
1300 MM DIA. Meter MAT-07222 2855
1400 MM DIA. Meter MAT-07223 3287
1500 MM DIA. Meter MAT-07224 3717
1600 MM DIA. Meter MAT-07225 3918
1700 MM DIA. Meter MAT-07226 4143
1800 MM DIA. Meter MAT-07227 4686
1900 MM DIA. Meter MAT-07228 5461
2000 MM DIA. Meter MAT-07229 6858
2100 MM DIA. Meter MAT-07230 7846
2200 MM DIA. Meter MAT-07231 8813
2300 MM DIA. Meter MAT-07232 10751
2400 MM DIA. Meter MAT-07233 13147

68
Public Health Engineering Items

2500 MM DIA. Meter MAT-07234 15269


2600 MM DIA. Meter MAT-07235 17189

The above rates of MS Spiral pipes are based on the following raw materials cost.
MS Plates = Rs.55,000/- Per MT.(Excluding all taxes and freight).

The rates may be revised depending upon the increase/decrease in the cost of raw materials
(landed price) as per the following method.

Revised Cost = Cost of the pipe as per the above table +R1
R1= (M2-M1)/1000 x Wm
M1= Rs 55,000/-
M2= Cost of MS Plates at the time of preparation of estimate excluding all taxes and freight
Wm=Weight of MS Plates in Kg’s per meter of pipe

69
Public Health Engineering Items

15. S.S. RATES FOR H.D.P.E PIPES FOR THE YEAR 2021-22. (PE - 80 Grade)

Sl.No Description 4.0 kg/sqcm


1 Manufacture, Supply, & Delivery of HDPE pipes conforming to IS 4984 -
2016 including transportation to anywhere in A.P, excluding all taxes (Supply
up to 90 mm dia. in coil & above 90 mm dia. straight Length)

Code Rate per Meter


OD 40 mm MAT-07236 38
OD 50 mm MAT-07237 56
OD 63 mm MAT-07238 77
OD 75 mm MAT-07239 106
OD 90 mm MAT-07240 151
OD 110 mm MAT-07241 226
OD 125 mm MAT-07242 289
OD 140 mm MAT-07243 361
OD 160 mm MAT-07244 472
OD 180 mm MAT-07245 597
OD 200 mm MAT-07246 729
OD 225 mm MAT-07247 924
OD 250 mm MAT-07248 1145
OD 280 mm MAT-07249 1426
OD 315 mm MAT-07250 1812
OD 355 mm MAT-07251 2361
OD 400 mm MAT-07252 3044
OD 450 mm MAT-07253 3887
OD 500 mm MAT-07254 4774
OD 560 mm MAT-07255 5912
OD 630 mm MAT-07256 7478
OD 710 mm MAT-07257 9502
OD 800 mm MAT-07258 12026
OD 900 mm MAT-07259 15238
OD 1000 mm MAT-07260 18767

Note: - Reliance Industries Resin cost adopted for the above rates are
For PE - 80 grade Rs.109039/- per MT. (Excluding all taxes).
The variation in cost of HDPE pipes due to increase / decrease in raw material cost shall be
allowed as per the following price variation formula.
P2 = P1 + (A2 - A1) /1000 x M x 0.95(for increase in raw material cost)
P2 = P1 - (A1 - A2) /1000 x M x 0.95(for decrease in raw material cost)
P2 = Revised pipe price in Rs. per Meter (Excluding all taxes).
P1 = Existing pipe price in Rs. per Meter (Excluding all taxes).
A2 = Revised price of raw material Rs. per MT excluding all taxes.
A1 = Existing price of raw material Rs. Per MT excluding all taxes
M = Weight of pipe in Kg’s per Meter as per weight chart.
The above formula for calculation of revised cost to be used for preparation of Estimates
only.

70
Public Health Engineering Items

16. S o R FOR H.D.P.E PIPES FOR THE YEAR 2021-22. (PE - 100 Grades)

Sl.N Description 6.0 kg/ 8.0 kg/ 10.0 kg/ 12.5 16.0
o. sqcm sqcm sqcm kg/ kg/
sqcm sqcm

1 Manufacture, Supply, & Delivery of HDPE Pipes conforming to IS 4984 - 2016 including transportation to anywhere in
A.P, excluding all taxes (Supply up to 90 mm dia. in coil & above 90 mm dia. straight length.)

Code Rate Code Rate Code Rate Code Rate Code Rate per
per per per per Meter
Meter Meter Meter Meter
OD 20 mm MAT- 27
07355
OD 25 mm MAT- 38
07356
OD 32 mm MAT- 42 MAT- 48 MAT- 62
07309 07333 07357
OD 40 mm MAT- 54 MAT- 65 MAT- 73 MAT- 94
07285 07310 07334 07358
OD 50 mm MAT- 68 MAT- 82 MAT- 100 MAT- 114 MAT- 146
07261 07286 07311 07335 07359
OD 63 mm MAT- 100 MAT- 125 MAT- 153 MAT- 179 MAT- 232
07262 07287 07312 07336 07360
OD 75 mm MAT- 142 MAT- 180 MAT- 215 MAT- 258 MAT- 329
07263 07288 07313 07337 07361
OD 90 mm MAT- 200 MAT- 255 MAT- 307 MAT- 367 MAT- 472
07264 07289 07314 07338 07362
OD 110 mm MAT- 305 MAT- 381 MAT- 454 MAT- 559 MAT- 724
07265 07290 07315 07339 07363
OD 125 mm MAT- 387 MAT- 491 MAT- 591 MAT- 741 MAT- 936
07266 07291 07316 07340 07364
OD 140 mm MAT- 485 MAT- 613 MAT- 742 MAT- 936 MAT- 1169
07267 07292 07317 07341 07365
OD 160 mm MAT- 637 MAT- 802 MAT- 965 MAT- 1210 MAT- 1532
07268 07293 07318 07342 07366
OD 180 mm MAT- 799 MAT- 1013 MAT- 1221 MAT- 1538 MAT- 1939
07269 07294 07319 07343 07367
OD 200 mm MAT- 991 MAT- 1252 MAT- 1505 MAT- 1909 MAT- 2384
07270 07295 07320 07344 07368
OD 225 mm MAT- 1277 MAT- 1615 MAT- 1949 MAT- 2401 MAT- 3026
07271 07296 07321 07345 07369
OD 250 mm MAT- 1572 MAT- 1995 MAT- 2406 MAT- 2980 MAT- 3729
07272 07297 07322 07346 07370
OD 280 mm MAT- 1969 MAT- 2499 MAT- 3015 MAT- 3723 MAT- 4674
07273 07298 07323 07347 07371
OD 315 mm MAT- 2493 MAT- 3165 MAT- 3814 MAT- 4695 MAT- 5906
07274 07299 07324 07348 07372
OD 355 mm MAT- 3129 MAT- 3967 MAT- 4780 MAT- 5778 MAT- 7523
07275 07300 07325 07349 07373
OD 400 mm MAT- 4107 MAT- 5200 MAT- 6255 MAT- 8169 MAT- 9711
07276 07301 07326 07350 07374
OD 450 mm MAT- 5110 MAT- 6484 MAT- 7817 MAT- 10329 MAT- 12269
07277 07302 07327 07351 07375
OD 500 mm MAT- 6314 MAT- 7998 MAT- 9644 MAT- 12761 MAT- 15224
07278 07303 07328 07352 07376
OD 560 mm MAT- 7345 MAT- 9302 MAT- 11153 MAT- 14314
07279 07304 07329 07353
OD 630 mm MAT- 9258 MAT- 11768 MAT- 14128 MAT- 16972
07280 07305 07330 07354
OD 710 mm MAT- 11790 MAT- 14918 MAT- 17945
07281 07306 07331
OD 800 mm MAT- 14954 MAT- 18943 MAT- 22859
07282 07307 07332

71
Public Health Engineering Items

OD 900 mm MAT- 18944 MAT- 23979


07283 07308
OD 1000 mm MAT- 23370
07284

Note: Reliance Industries Resin cost adopted for the above rates are

For PE - 100 grade Rs.110139/-per MT. (Excluding all taxes).


The variation in cost of HDPE pipes due to increase / decrease in raw material cost shall be
allowed as per the following price variation formula.

P2 = P1 + (A2 - A1) /1000 x M x 0.95(for increase in raw material cost)


P2 = P1 - (A1 - A2) /1000 x M x 0.95(for decrease in raw material cost)
P2 = Revised pipe price in Rs. per Meter (Excluding all taxes).
P1 = Existing pipe price in Rs. per Meter (Excluding all taxes).
A2 = Revised price of raw material Rs. per MT excluding all taxes
A1 = Existing price of raw material Rs. per MT excluding all taxes
M = Weight of pipe in Kg’s per Meter as per weight chart.

The above formula for calculation of revised cost to be used for preparation of Estimates
only.

72
Public Health Engineering Items

17.HDPE PIPES – (PE –100 Grade) SEWER LINES FOR THE YEAR 2021-22

6.0 kg/ 8.0 kg/ 10.0 kg/ 12.5 16.0


Sl.N sqcm sqcm sqcm kg/ kg/
Description
o sqcm sqcm
1 Manufacture, Supply, & Delivery of HDPE Pipes are conforming to IS 14333 - 2000 for using underground drainage and sewerage systems
including transportation to anywhere in A.P, excluding all taxes (Supply up to 90 mm drain coil & above 90 mm dia. straight length)

Rate per Rate per Rate per Code Rate per Code Rate per
Meter Meter Meter Meter Meter
Code Code Code
MAT- MAT- MAT- MAT- MAT-
OD 63mm 110 138 166 197 236
07377 07400 07420 07439 07456
MAT- MAT- MAT- MAT- MAT-
OD 75 mm 155 199 236 281 335
07378 07401 07421 07440 07457
MAT- MAT- MAT- MAT- MAT-
OD 90 mm 220 282 335 399 484
07379 07402 07422 07441 07458
MAT- MAT- MAT- MAT- MAT-
OD 110 mm 318 402 480 576 688
07380 07403 07423 07442 07459
MAT- MAT- MAT- MAT- MAT-
OD 125 mm 407 519 622 736 890
07381 07404 07424 07443 07460
MAT- MAT- MAT- MAT- MAT-
OD 140 mm 509 647 779 928 1117
07382 07405 07425 07444 07461
MAT- MAT- MAT- MAT- MAT-
OD 160 mm 662 845 1017 1183 1453
07383 07406 07426 07445 07462
MAT- MAT- MAT- MAT- MAT-
OD 180 mm 835 1072 1286 1527 1838
07384 07407 07427 07446 07463
MAT- MAT- MAT- MAT- MAT-
OD 200 mm 1034 1322 1585 1892 2266
07385 07408 07428 07447 07464
MAT- MAT- MAT- MAT- MAT-
OD 225 mm 1305 1666 2004 2384 2871
07386 07409 07429 07448 07465
MAT- MAT- MAT- MAT- MAT-
OD 250 mm 1611 2062 2473 2944 3537
07387 07410 07430 07449 07466
MAT- MAT- MAT- MAT- MAT-
OD 280 mm 2013 2578 3085 3701 4442
07388 07411 07431 07450 07467
MAT- MAT- MAT- MAT- MAT-
OD 315 mm 2548 3265 3972 4670 5616
07389 07412 07432 07451 07468
MAT- MAT- MAT- MAT- MAT-
OD 355 mm 3228 4135 4975 5938 7125
07390 07413 07433 07452 07469
MAT- MAT- MAT- MAT- MAT-
OD 400 mm 4265 5459 6553 7813 9370
07391 07414 07434 07453 07470
MAT- MAT- MAT- MAT-
OD 450 mm 5383 6905 8299 9872
07392 07415 07435 07454
MAT- MAT- MAT- MAT-
OD 500 mm 6654 8513 10235 12201
07393 07416 07436 07455
MAT- MAT- MAT-
OD 560 mm 8320 10668 12842
07394 07417 07437
MAT- MAT- MAT-
OD 630 mm 10535 13504 16224
07395 07418 07438
MAT- MAT-
OD 710 mm 13645 17482
07396 07419
MAT-
OD 800 mm 17313
07397
MAT-
OD 900 mm 21927
07398
MAT-
OD 1000 mm 27092
07399

73
Public Health Engineering Items

Note: Reliance Industries Resin cost adopted for the above rates are

For PE - 100 grade Rs.110139/-per MT. (Excluding all taxes).

The variation in cost of HDPE pipes due to increase / decrease in raw material cost shall be
allowed as per the following price variation formula.

P2 = P1 + (A2 - A1) /1000 x M x 0.95(for increase in raw material cost)


P2 = P1 - (A1 - A2) /1000 x M x 0.95(for decrease in raw material cost)
P2 = Revised pipe price in Rs. per Meter excluding all taxes
P1 = Existing pipe price in Rs. per Meter excluding all taxes
A2 = Revised price of raw material Rs. per MT excluding all taxes
A1 = Existing price of raw material Rs. per MT excluding all taxes
M = Weight of pipe in Kgs per Meter as per weight chart.

The above formula for calculation of revised cost to be used for preparation of Estimates
only.

74
Public Health Engineering Items

18. S o R FOR H.D.P.E- (PE –100 Grade) FITTINGS FOR THE YEAR 2021-22.

Manufacture, Supply, & Delivery of HDPE (PE –100 Grade) fittings conforming to
I
IS 4984 - 2016 including transportation to anywhere in A.P. Excluding all taxes.
I (a) PIPE ENDS LONG NECK Code Rate per Each
OD 50 mm MAT-07471 77
OD 63 mm MAT-07472 98
OD 75 mm MAT-07473 117
OD 90 mm MAT-07474 164
OD 110 mm MAT-07475 226
OD 125 mm MAT-07476 407
OD 140 mm MAT-07477 381
OD 160 mm MAT-07478 533
OD 180 mm MAT-07479 811
OD 200 mm MAT-07480 1043
OD 225 mm MAT-07481 1198
OD 250 mm MAT-07482 1403
OD 280 mm MAT-07483 1568
OD 315 mm MAT-07484 1807
OD 355 mm MAT-07485 3778
OD 400 mm MAT-07486 5034
OD 450 mm MAT-07487 8376
OD 500 mm MAT-07488 9322
(b) MS FLANGES Code Rate per Each
OD 50 mm MAT-07489 94
OD 63 mm MAT-07490 118
OD 75 mm MAT-07491 152
OD 90 mm MAT-07492 164
OD 110 mm MAT-07493 172
OD 125 mm MAT-07494 236
OD 140 mm MAT-07495 256
OD 160 mm MAT-07496 336
OD 180 mm MAT-07497 474
OD 200 mm MAT-07498 613
OD 225 mm MAT-07499 768
OD 250 mm MAT-07500 908
OD 280 mm MAT-07501 1028
OD 315 mm MAT-07502 1211
OD 355 mm MAT-07503 2050
OD 400 mm MAT-07504 2542
OD 450 mm MAT-07505 3319
OD 500 mm MAT-07506 3800
(c) END CAPS Code Rate per Each

75
Public Health Engineering Items

OD 50 mm MAT-07507 57
OD 63 mm MAT-07508 67
OD 75 mm MAT-07509 84
OD 90 mm MAT-07510 112
OD 110 mm MAT-07511 128
OD 125 mm MAT-07512 178
OD 140 mm MAT-07513 208
OD 160 mm MAT-07514 317
OD 180 mm MAT-07515 515
OD 200 mm MAT-07516 563
OD 225 mm MAT-07517 586
OD 250 mm MAT-07518 834
OD 280 mm MAT-07519 854
OD 315 mm MAT-07520 1166
OD 355 mm MAT-07521 1801
OD 400 mm MAT-07522 3145
OD 450 mm MAT-07523 5058
OD 500 mm MAT-07524 9322
(d) REDUCERS Code Rate per Each
OD 50 mm x 63 mm MAT-07525 77
OD 63 mm x 75 mm MAT-07526 112
OD 75 mm x 90 mm MAT-07527 185
OD 90 mm x 110 mm MAT-07528 255
OD 110 mm x 125 mm MAT-07529 388
OD 125 mm x 140 mm MAT-07530 538
OD 140 mm x 160 mm MAT-07531 751
OD 160 mm x 180 mm MAT-07532 1038
OD 180 mm x 200 mm MAT-07533 1341
OD 200 mm x 225 mm MAT-07534 1647
OD 225 mm x 250 mm MAT-07535 2245
OD 250 mm x 280 mm MAT-07536 3188
OD 280 mm x 315 mm MAT-07537 4508
OD 315 mm x 355 mm MAT-07538 5171
OD 355 mm x 400 mm MAT-07539 7295
OD 400 mm x 450 mm MAT-07540 7568
OD 450 mm x 500 mm MAT-07541 9703

(e) TEES Code Rate per Each


OD 50 mm MAT-07542 108
OD 63 mm MAT-07543 171
OD 75 mm MAT-07544 208
OD 90 mm MAT-07545 364

76
Public Health Engineering Items

OD 110 mm MAT-07546 431


OD 125 mm MAT-07547 649
OD 140 mm MAT-07548 895
OD 160 mm MAT-07549 1542
OD 180 mm MAT-07550 2090
OD 200 mm MAT-07551 2879
OD 225 mm MAT-07552 4087
OD 250 mm MAT-07553 5596
OD 280 mm MAT-07554 7837
OD 315 mm MAT-07555 11167
OD 355 mm MAT-07556 15925
OD 400 mm MAT-07557 23325
MAT-07558 33132
OD 450 mm
MAT-07559 45502
OD 500 mm
Rate per
(f) BENDS
Code Each
OD 50 mm MAT-07560 67
OD 63 mm MAT-07561 151
OD 75 mm MAT-07562 196
OD 90 mm MAT-07563 334
OD 110 mm MAT-07564 442
OD 125 mm MAT-07565 653
OD 140 mm MAT-07566 859
OD 160 mm MAT-07567 1282
OD 180 mm MAT-07568 1841
OD 200 mm MAT-07569 2492
OD 225 mm MAT-07570 3538
OD 250 mm MAT-07571 4848
OD 280 mm MAT-07572 6989
OD 315 mm MAT-07573 9667
OD 355 mm MAT-07574 13400
OD 400 mm MAT-07575 20214
OD 450 mm MAT-07576 29716
OD 500 mm MAT-07577 40287

77
Public Health Engineering Items

II Providing and Fixing electro Fusion Ferrule Tapping saddle manufactured from
virgin resin of PE-80/PE-100 having blue/black color using food grade compounded
raw material with quality assurance certificate from quality agencies like CIPET etc.
For usage in drinking water system and having working pressure of 10 bar. The cost
shall include testing of all materials, labor all taxes (central & state), inspection
charges, transportation up to site, transit insurance, loading, unloading, stacking,
providing and fixing etc. Complete as specified and directed by the Departmental
Engineers.
SIZE Code Rate Each
(Main pipe outer diameter in mm & Tapping size in
Inches)
63x1/2” MAT-07578 967
63 x3/4” MAT-07579 967
63 x1” MAT-07580 967
63 x1/2” MAT-07581 967
75 x1/2” MAT-07582 967
75 x3/4” MAT-07583 967
75 x1 MAT-07584 967
90 x1/2” MAT-07585 967
90 x3/4” MAT-07586 967
90 x1” MAT-07587 967
90 x 1 1/4” MAT-07588 1254
90 x 1 1/2” MAT-07589 1254
90 x2” MAT-07590 1254
110x1/2” MAT-07591 967
110 x3/4” MAT-07592 967
110 x1” MAT-07593 967
110 x 1 1/4” MAT-07594 1254
110x1 1/2” MAT-07595 1254
110x2” MAT-07596 1254
160 x1/2” MAT-07597 967
160 x3/4” MAT-07598 967
160 x1” MAT-07599 967
160 x 1 1/4” MAT-07600 1371
160 x 1 1/2” MAT-07601 1371
160 x 2” MAT-07602 1371
200 x 1/2” MAT-07603 1371
200 x 3/4” MAT-07604 1371
200 x 1” MAT-07605 1371

78
Public Health Engineering Items

200 x 1 1/4” MAT-07606 1973


200 x 2” MAT-07607 1973
250 x 1/2” MAT-07608 1390
250 x3/4” MAT-07609 1390
250 x1” MAT-07610 1390
250 x 1 1/4” MAT-07611 2009
250 x1 1/2” MAT-07612 2009
250 x 2” MAT-07613 2009
315 x 1/2” MAT-07614 1655
315 x3/4” MAT-07615 1655
315x1” MAT-07616 1655
315x1 1/4” MAT-07617 2248
315x1 1/2” MAT-07618 2248
315x2” MAT-07619 2248

Note: For Item No.18( II ).


(A) The above rates are including taxes of 18% GST. The same may be
deducted for obtaining basic rates.
(B) The rates for estimate purpose may be compared with market rates by quotations and may
be adopted by considering which ever is less.

79
Public Health Engineering Items

19. S o R FOR Double Wall Corrugated (DWC) Pipes FOR THE YEAR 2021-22

SoR
Sl.No. Description Unit Code RATES
2021-22

1 2 3 4 5
I Manufacture, supply, & delivery of (DWC) Meter
structured wall polyethylene/polypropylene
piping system with non smooth external
annular corrugated and smooth internal surface
(Double Wall) for non pressure sewage &
Drainage application pipes of standard length 6
m, grade conforming to IS 16098 (part-II:
2013) including transportation to anywhere in
A.P, excluding all taxes.
Inner Dia. (mm)
Stiffness Class SN-8
100 MAT-07620 180
135 MAT-07621 270
150 MAT-07622 320
170 MAT-07623 384
200 MAT-07624 529
250 MAT-07625 825
300 MAT-07626 1099
400 MAT-07627 1988
500 MAT-07628 2898
600 MAT-07629 4996
800 MAT-07630 8284
1000 MAT-07631 13490

80
Public Health Engineering Items

SoR
Sl.No. Description Unit Code RATES
2021-22

1 2 3 4 5
II Laying of Alcorr or similar type of Class SN8 Meter
structured wall (External Annular Corrugated &
Smooth Internal surface) Polythelene pipes, on
the lower bedding (Constructed at bottom of
trenches) at prescribed gradient, depth &
alignment including installation and jointing of
the same with the help of coupler (on line/ off
line) attached to one end of the pipe & sliding
the coupler end over the elastomeric sealing
rubber ring fitted on the specified valley of the
spigot end of next pipe, testing the water
tightness of the joint assembly, ensuring the
continuity tests of specified pipe segments etc.
complete as per drawing, specifications & detail
engineering, including carriage of pipes &
fittings from site stacks to the place of laying
etc. as per direction of Engineer-in-charge.
(Payment to be made on the basis of actual
finished length of pipe line).
Inner Dia. (mm)
Stiffness Class SN-8
100 31
135 48
150 57
170 68
200 94
250 147
300 195
400 352
500 513
600 885
800 1467

Manufacture, supply, & delivery of fittings & accessories compatible with Alcorr
III (DWC pipe) - non smooth External Annular Corrugated and smooth Internal Surfaces
(Double Wall) for non-pressure or similar type of class SN8 Structured Wall
polythelene piping systems including transportation to any where in A.P, excluding
GST and other Government duties.
Inner Dia. (mm)
(a) Coupler Code Rate per Each

81
Public Health Engineering Items

100 68
135 114
150 129
170 157
200 212
250 902
300 1313
400 1952
500 3823
600 4950
800 10492
1000 13790
(b) Sealing Ring Code Rate per Each
100 21
135 27
150 32
170 46
200 83
250 182
300 466
400 720
500 1,097
600 2,429
800 5,847
1000 8,244

82
Public Health Engineering Items

20. SoR FOR PVC PIPES FOR THE YEAR 2021-22


TEST PRESSURE
Sl.
Description
No. 4.0 Kgs/cm2 6 Kgs/cm2 10 Kgs/cm2

Manufacture, Supply and Delivery of Unplasticised PVCs Pipes for potable water
supplies conforming to IS : 4985/2000 (3rd revision) with bell ends (Socket) as per
specification in light Grey/Natural Ivory Grey/ Any other Color (except White)
1 inclusive of transportation to the sub-divisional stores anywhere in AP excluding all
taxes.

Rate/ Rate/M Rate/M


DIA. IN MM Code Code Code
Meter eter eter
MAT-
20 22
07664
MAT-
33
25 07665
MAT-
32 07666
50
MAT- MAT-
47 77
40 07647 07667
MAT- MAT-
50 70 119
07648 07668
MAT- MAT- MAT-
77 112 167
63 07632 07649 07669
MAT- MAT- MAT-
75 07633
111 07650
153 07670
242
MAT- MAT- MAT-
90 07634
154 07651
221 07671
343
MAT- MAT- MAT-
223 320 514
110 07635 07652 07672
MAT- MAT- MAT-
125 292 412 668
07636 07653 07673
MAT- MAT- MAT-
140 364 526 829
07637 07654 07674
MAT- MAT- MAT-
160 07638
478 07655
679 07675
1087
MAT- MAT- MAT-
180 07639
610 07656
873 07676
1387
MAT- MAT- MAT-
200 07640
740 07657
1068 07677
1695
MAT- MAT- MAT-
225 1005 1453 2308
07641 07658 07678
MAT- MAT- MAT-
250 1163 1749 2771
07642 07659 07679
MAT- MAT- MAT-
1503 2207 3490
280 07643 07660 07680
MAT- MAT- MAT-
315 07644
1908 07661
2801 07681
4419
MAT- MAT-
355 07645
2472 07662
3590
MAT- MAT-
400 3118 4567
07646 07663

83
Public Health Engineering Items

Note:
The resin cost adopted for the above rates is Rs.127330/- per MT (excluding all taxes)
The variation in cost of PVC pipes due to increase / decrease in raw material cost shall be
allowed subject to the following price variation formula.
The price variation formula to be adopted is as follows:
P2 = P1 + (A2 - A1) /1000 x M x 0.95 (for increase in raw material cost)
P2 = P1 - (A1 - A2) /1000 x M x 0.95 (for decrease in raw material cost)
P2 = Revised pipe price in Rs. Per Meter, P1 = Existing pipe price in Rs. Per Meter
A2 = Revised price of raw material Rs. Per MT,
A1 = Existing price of raw material Rs. Per MT
M = Weight of pipe in Kgs per Meter as per weight chart.

The above formula for calculation of revised cost to be used for preparation of Estimates
only.

84
Public Health Engineering Items

21. SoR FOR NON- PRESSURE P.V.C.U PIPES FOR THE YEAR 2021-22

S. No Description
1 Manufacture, Supply, & Delivery of Unplasticised Non-pressure
polyvinyl chloride(PVC-U) pipes of dark (any shade of brown) for use in
underground drainage & sewerage system conforming to IS
15328/2003) with solvent cement jointing as per specification inclusive
of transportation to the sub-divisional stores anywhere in A.P,
excluding all taxes
Pipe Series (S25) Code Rate per
Meter
OD 160 mm MAT-07682 420
OD 200 mm MAT-07683 638
OD 250mm MAT-07684 990
OD 315 mm MAT-07685 1562
Pipe Series (S20)
OD 125 mm MAT-07686 324
OD 160 mm MAT-07687 520
OD 200 mm MAT-07688 789
OD 250mm MAT-07689 1230
OD 315 mm MAT-07690 1930
Pipe Series (S16.5)
OD 110 mm MAT-07691 286
OD 125 mm MAT-07692 386
OD 160 mm MAT-07693 604
OD 200 mm MAT-07694 938
OD 250mm MAT-07695 1455
OD 315 mm MAT-07696 2296

Note: The resin cost adopted for the above rates is Rs.127330/- per MT (Excluding all taxes).
The variation in cost of PVC pipes due to increase / decrease in raw material cost shall be
allowed subject to the following price variation formula.
The price variation formula to be adopted is as follows:
P2 = P1 + (A2 - A1) /1000 x M x 0.95 (for increase in raw material cost)
P2 = P1 - (A1 - A2) /1000 x M x 0.95 (for decrease in raw material cost)
P2 = Revised pipe price in Rs. per Meter
P1 = Existing pipe price in Rs. per Meter
A2 = Revised price of raw material Rs. per MT
A1 = Existing price of raw material Rs. per MT
M = Weight of pipe in Kg’s per Meter as per weight chart.
The above formula for calculation of revised cost to be used for preparation of Estimates
only.

85
Public Health Engineering Items

22. SoR FOR NON- PRESSURE P.V.C.U PIPES FOR THE YEAR 2021-22

S. No Description
1 Manufacture, supply, & delivery of un-plasticized Non-Pressure Polyvinyl
Chloride(PVC-U) pipes of dark (any shade of Brown) for use in underground
drainage & sewerage system conforming to IS 15328/2003) with Elastomeric
Seal Ring Joints (Ringtite PVC Pipes)as per specification inclusive of
transportation to the Sub-Divisional stores anywhere in A.P, excluding all taxes

Pipe Series (S25) Code Rate per Meter


OD 160 mm MAT-07697 446
OD 200 mm MAT-07698 676
OD 250mm MAT-07699 1052
OD 315 mm MAT-07700 1657
Pipe Series (S20)
OD 125 mm MAT-07701 347
OD 160 mm MAT-07702 549
OD 200 mm MAT-07703 835
OD 250mm MAT-07704 1302
OD 315 mm MAT-07705 2044
Pipe Series (S16.5)
OD 110 mm MAT-07706 303
OD 125 mm MAT-07707 409
OD 160 mm MAT-07708 641
OD 200 mm MAT-07709 989
OD 250mm MAT-07710 1537
OD 315 mm MAT-07711 2427

Note: The resin cost adopted for the above rates is Rs.127330/- per MT (Excluding all
taxes).The variation in cost of PVC pipes due to increase / decrease in raw material cost shall
be allowed subject to the following price variation formula.
The price variation formula to be adopted is as follows:
P2 = P1 + (A2 - A1) /1000 x M x 0.95 (for increase in raw material cost)
P2 = P1 - (A1 - A2) /1000 x M x 0.95 (for decrease in raw material cost)
P2 = Revised pipe price in Rs. per Meter
P1 = Existing pipe price in Rs. per Meter
A2 = Revised price of raw material Rs. per MT
A1 = Existing price of raw material Rs. per MT
M = Weight of pipe in Kg’s per Meter as per weight chart.
The above formula for calculation of revised cost to be used for preparation of Estimates
only.

86
Public Health Engineering Items

23. SoR FOR CENTRIFUGALLY CAST (SPUN) IRON PRESSURE PIPES

Sl. No. Description Unit S.S. Rates for 2021-22


Socket and Spigot Centrifugally Cast (Spun) Iron pressure pipes for water, Gas and
Sewage conforming to specification No: IS 1536/1989 (third revision) with amdt. No:
1 & 2 in standard lengths of 3.66 m, 4 m, 4.5m, 5 m, 5.5 m & 6 m and details given
I below, suitable either for lead jointing or rubber gasket (push on) jointing at
purchasers option at ex-factory excluding transportation and all taxes.
Nominal dia. LA A B
Code Code Code
(in MM) Class Class Class
80 Rmt MAT-07712 888 MAT-07729 966 MAT-07746 1033
100 Rmt MAT-07713 1100 MAT-07730 1211 MAT-07747 1292
125 Rmt MAT-07714 1421 MAT-07731 1553 MAT-07748 1670
150 Rmt MAT-07715 1723 MAT-07732 1888 MAT-07749 2028
200 Rmt MAT-07716 2519 MAT-07733 2733 MAT-07750 2950
250 Rmt MAT-07717 3395 MAT-07734 3696 MAT-07751 3987
300 Rmt MAT-07718 4378 MAT-07735 4786 MAT-07752 5172
350 Rmt MAT-07719 5515 MAT-07736 5982 MAT-07753 6471
400 Rmt MAT-07720 6712 MAT-07737 7334 MAT-07754 7897
450 Rmt MAT-07721 8094 MAT-07738 8892 MAT-07755 9565
500 Rmt MAT-07722 9474 MAT-07739 10322 MAT-07756 11136
600 Rmt MAT-07723 12626 MAT-07740 13784 MAT-07757 14889
700 Rmt MAT-07724 16295 MAT-07741 17802 MAT-07758 19178
750 Rmt MAT-07725 18248 MAT-07742 19952 MAT-07759 21584
800 Rmt MAT-07726 20428 MAT-07743 22258 MAT-07760 24010
900 Rmt MAT-07727 24882 MAT-07744 27148 MAT-07761 29333
1000 Rmt MAT-07728 29893 MAT-07745 32656 MAT-07762 35189
II Conveyance of Centrifugally Cast (Spun) Iron Pressure Pipes and accessories
including loading at Factory, un-loading at site and stacking for the following sizes.
(The Minimum distance/lead in Km for destination below 100 Km to be taken as 100
Km)
SIZE IN MM LA A B
UNIT
80 0.29 0.29 0.29
Per
KM/RMT
100 0.29 0.29 0.29
Per
KM/RMT
125 0.44 0.44 0.44
Per
KM/RMT
150 0.44 0.44 0.44
Per
KM/RMT
200 0.74 0.74 0.74

87
Public Health Engineering Items

Per
KM/RMT
250 0.89 0.89 0.89
Per
KM/RMT
300 1.17 1.17 1.17
Per
KM/RMT

350 1.61 1.61 1.61


Per
KM/RMT
400 1.90 1.90 1.90
Per
KM/RMT
450 2.20 2.20 2.20
Per
KM/RMT
500 2.63 2.63 2.63
Per
KM/RMT
600 2.63 2.63 2.63
Per
KM/RMT
700 2.63 2.63 2.63
Per
KM/RMT
750 4.38 4.38 4.38
Per
KM/RMT
800 7.45 7.45 7.45
Per
KM/RMT
900 7.45 7.45 7.45
Per
KM/RMT
1000 7.45 7.45 7.45
Per
KM/RMT
Note: Price Variation Formula due to Increase / Decrease in the cost of pig iron.
P2=P1+ (R2-R1)/1000*M*1.0
Where M= Weight of pipe in kg per Meter.
P2 = Revised rate of pipe in Rs. per Rmt
P1 = Rate of pipe in Rs. per Rmt as per above table.
R2 = Price of Pig Iron (Rs per MT excluding all taxes) at the time of preparation of
estimate.
R1 = Price of Pig Iron (Rs per MT excluding all taxes) at the time of preparation of SSR =Rs.
38,000/-
The above formula for calculation of revised cost to be used for preparation of Estimates
only.

88
Public Health Engineering Items

24.S o R FOR DUCTILE IRON PRESSURE PIPES FOR THE YEAR 2021-22
Sl.
Description Unit Class of Pipe
No.
Centrifugally cast (Spun) Ductile Iron pressure pipes for water, gas and sewage with
Socket Spigot ends conforming to IS.: 8329/2000 in standard working lengths of 4, 5 5.5 &
1 6 meter for classification K9 & K7 suitable for push-on-joint (rubber gasket d jointing)
with cement mortar lining inside the pipes with outside zinc coating. Rates are ex-factory,
excluding transportation and all taxes.
Nominal Dia. in Rmt Code K9
Code K7
mm
80 Rmt 740 868
100 Rmt MAT-07763 880 MAT-07778 1053
150 Rmt MAT-07764 1267 MAT-07779 1569
200 Rmt MAT-07765 1726 MAT-07780 2086
250 Rmt MAT-07766 2301 MAT-07781 2765
300 Rmt MAT-07767 2936 MAT-07782 3532
350 Rmt MAT-07768 3779 MAT-07783 4469
400 Rmt MAT-07769 4533 MAT-07784 5331
450 Rmt MAT-07770 5486 MAT-07785 6436
500 Rmt MAT-07771 6463 MAT-07786 7416
600 Rmt MAT-07772 8673 MAT-07787 9896
700 Rmt MAT-07773 11026 MAT-07788 12489
750 Rmt MAT-07774 12478 MAT-07789 14173
800 Rmt MAT-07775 13686 MAT-07790 15411
900 Rmt MAT-07776 16862 MAT-07791 18949
1000 Rmt MAT-07777 19865 MAT-07792 22268
1100 Rmt MAT-07793 24135
1200 Rmt MAT-07794 28220
Centrifugally cast (Spun) Ductile Iron pressure pipes for water, gas and sewage with plain
ends conforming to IS:8329/2000in standard working lengths of 4, 5, 5.5 & 6 meter for
2
classification K9 & K7 with cement mortar lining inside the pipes with outside zinc
coating. Rates are ex-factory, excluding transportation and all taxes.
Nominal Dia. in Code K9
Code K7
mm
100 Rmt MAT-07795 784 MAT-07810 1002
150 Rmt MAT-07796 1160 MAT-07811 1480
200 Rmt MAT-07797 1602 MAT-07812 2006
250 Rmt MAT-07798 2085 MAT-07813 2663
300 Rmt MAT-07799 2756 MAT-07814 3399
350 Rmt MAT-07800 3474 MAT-07815 4224
400 Rmt MAT-07801 4197 MAT-07816 5092

89
Public Health Engineering Items

450 Rmt MAT-07802 5015 MAT-07817 6021


500 Rmt MAT-07803 5976 MAT-07818 7176
600 Rmt MAT-07804 7902 MAT-07819 9270
700 Rmt MAT-07805 10420 MAT-07820 11760
750 Rmt MAT-07806 11647 MAT-07821 13139
800 Rmt MAT-07807 12887 MAT-07822 14521
900 Rmt MAT-07808 15598 MAT-07823 17541
1000 Rmt MAT-07809 18525 MAT-07824 20874
1100 Rmt MAT-07825 22347
1200 Rmt MAT-07826 23632
Centrifugally cast (Spun) Ductile Iron pressure pies with flanged (welded) ends for water,
gas, sewage conforming to IS: 8329/2000 in standard working lengths of 1,2,3, 4, 5 mts for
3
classification K9 with cement mortar lining inside the pipes with outside zinc coating.
Rates are ex-factory, excluding transportation and all taxes.
Nominal 1.0 Mt. 2.0 Mt. 3.0 Mt. 4.0 Mt. 5.0 Mt.
Unit Code Code Code Code Code
Dia. in mm Length Length Length Length Length
80 Each 2974 3774 4542 5200 7215

100 Each MAT- 3269 MAT- 4181 MAT- 5089 MAT- 6001 MAT- 7990
07827 07842 07857 07872 07887
150 Each MAT- 5245 MAT- 6991 MAT- 7372 MAT- 7713 MAT- 10863
07828 07843 07858 07873 07888
200 Each MAT- 6955 MAT- 9339 MAT- 9480 MAT- 10210 MAT- 14126
07829 07844 07859 07874 07889
250 Each MAT- 9081 MAT- 12264 MAT- 13288 MAT- 13773 MAT- 19190
07830 07845 07860 07875 07890
300 Each MAT- 11653 MAT- 15701 MAT- 17532 MAT- 17923 MAT- 24713
07831 07846 07861 07876 07891
350 Each MAT- 21302 MAT- 23865 MAT- 24754 MAT- 27073 MAT- 34567
07832 07847 07862 07877 07892
400 Each MAT- 24991 MAT- 31074 MAT- 33937 MAT- 34091 MAT- 40874
07833 07848 07863 07878 07893
450 Each MAT- 31967 MAT- 39276 MAT- 42120 MAT- 42999 MAT- 50507
07834 07849 07864 07879 07894
500 Each MAT- 40807 MAT- 49497 MAT- 50856 MAT- 51082 MAT- 60121
07835 07850 07865 07880 07895
600 Each MAT- 47131 MAT- 58912 MAT- 65947 MAT- 66793 MAT- 84434
07836 07851 07866 07881 07896
700 Each MAT- 66360 MAT- 80486 MAT- 83432 MAT- 85522 MAT- 92172
07837 07852 07867 07882 07897
800 Each MAT- 78202 MAT- 95323 MAT- 98899 MAT- 107065 MAT- 118008
07838 07853 07868 07883 07898
900 Each MAT- 82911 MAT- 103685 MAT- 117969 MAT- 134168 MAT- 147682
07839 07854 07869 07884 07899
1000 Each MAT- 113682 MAT- 138124 MAT- 147535 MAT- 167133 MAT- 183349
07840 07855 07870 07885 07900
1100 Each MAT- 134238 MAT- 161162 MAT- 184443 MAT- 197334 MAT- 223562
07841 07856 07871 07886 07901
Conveyance of Ductile Iron Pressure Pipes WELDED
and accessories including loading at Factory, DOUBLE
4 Class
un-loading at site and stacking for the FLANGED
following sizes PIPES
SIZE IN MM UNIT K7 K9 K9
80 Per KM/RMT 0.20 0.20 0.30
100 Per KM/RMT 0.23 0.23 0.35
150 Per KM/RMT 0.35 0.35 0.46

90
Public Health Engineering Items

200 Per KM/RMT 0.35 0.46 0.69


250 Per KM/RMT 0.46 0.58 0.92
300 Per KM/RMT 0.69 0.69 1.16
350 Per KM/RMT 0.81 0.92 1.39
400 Per KM/RMT 0.92 1.04 1.62
450 Per KM/RMT 1.16 1.27 1.96
500 Per KM/RMT 1.39 1.50 2.31
600 Per KM/RMT 1.96 1.96 3.00
700 Per KM/RMT 2.89 2.89 4.39
750 Per KM/RMT 3.47 3.47 5.31
800 Per KM/RMT 5.89 5.89 8.78
900 Per KM/RMT 5.89 5.89 8.78
1000 Per KM/RMT 5.89 5.89 8.78
1100 Per KM/RMT 5.89 5.89 8.78

Supply and Delivery of Polyethylene (PE) Sleeves for Ductile Iron Pipes used to guard
5
the pipe against corrosion.
DIA. IN MM
RMT MAT-07902 45.00
100 MM DIA.
RMT MAT-07903 55.00
150 MM DIA.
RMT MAT-07904 70.00
200 MM DIA.
RMT MAT-07905 81.00
250 MM DIA.
RMT MAT-07906 89.00
300 MM DIA.
RMT MAT-07907 100.00
350 MM DIA.
RMT MAT-07908 140.00
400 MM DIA.
RMT MAT-07909 140.00
450 MM DIA.
RMT MAT-07910 169.00
500 MM DIA.
RMT MAT-07911 169.00
600 MM DIA.
RMT MAT-07912 220.00
700 MM DIA.
RMT MAT-07913 220.00
750 MM DIA.
RMT MAT-07914 220.00
800 MM DIA.
RMT MAT-07915 250.00
900 MM DIA.
RMT MAT-07916 250.00
1000 MM DIA.
RMT MAT-07917 308.00
1100 MM DIA.
6 Additional price for HAC(high alumina cement mortar lining)
DIA. IN MM
RMT MAT-07918 67.00
100 MM DIA.
RMT MAT-07919 88.00
150 MM DIA.

91
Public Health Engineering Items

RMT MAT-07920 108.00


200 MM DIA.
RMT MAT-07921 129.00
250 MM DIA.
RMT MAT-07922 138.00
300 MM DIA.
RMT MAT-07923 157.00
350 MM DIA.
RMT MAT-07924 216.00
400 MM DIA.
RMT MAT-07925 216.00
450 MM DIA.
RMT MAT-07926 266.00
500 MM DIA.
RMT MAT-07927 266.00
600 MM DIA.
RMT MAT-07928 341.00
700 MM DIA.
RMT MAT-07929 341.00
750 MM DIA.
RMT MAT-07930 341.00
800 MM DIA.
RMT MAT-07931 389.00
900 MM DIA.
RMT MAT-07932 389.00
1000 MM DIA.
RMT MAT-07933 389.00
1100 MM DIA.
RMT MAT-07934 389.00
1200 MM DIA.

Note: Price Variation Formula due to Increase / Decrease in the cost of pig iron.
P2=P1+ (R2-R1)/1000*M*0.96, Where
M = Weight of pipe in kg per Meter as per I.S.8329-2000.
P2 = Revised rate of pipe in Rs. per Rmt.
P1 = Rate of pipe in Rs. per Rmt. as per above table.
R2 = Price of Pig Iron(Rs per MT)) at the time of preparation of estimate.
R1 = Price of Pig Iron(Rs per MT) at the time of preparation
Of SoR =Rs.38,000/-(Excluding all taxes).
The above formula for calculation of revised cost to be used for preparation of Estimates
only.

92
Public Health Engineering Items

25. S o R FOR DUCTILE IRON FITTINGS FOR THE YEAR 2021-22

Sl. No. Description Unit Code Rate


Centrifugally cast (spun) Ductile Iron Fittings conforming to IS:9523/2000
having dimensions as per table. The rates mentioned here under are for fittings,
zinc coated externally with inside mortar lining (with finishing as per class
13/IS 9523/2000) ( ex-works) Excluding Transportation and all Taxes.
I DI double socket branch flange Tee
Up to 500 x 500 mm dia. Kg MAT-07935 118.52
Above 500 x 500 mm dia. Kg MAT-07936 131.52

II DI All Socket Tees


Up to 300 x 300 mm dia. Kg MAT-07937 118.52
Above 300 x 300 mm dia. Kg MAT-07938 131.52

III DI Double socket Tapers (Reducer)


Up to 500 x 450 mm dia. Kg MAT-07939 118.52
Above 500 x 450 mm dia. Kg MAT-07940 131.52

IV DI Flanged Socket
Up to 500 mm dia. Kg MAT-07941 118.52
Above 500 mm dia. Kg MAT-07942 131.52

V DI Flanged Spigot
Up to 500 mm dia. Kg MAT-07943 118.52
Above 500 mm dia. Kg MAT-07944 131.52

VI DI Double Socket Duck Foot Bend


Up to 300mm dia. Kg MAT-07945 118.52
Above 300mm dia. Kg MAT-07946 131.52

VII DI Double Flange Duck/Foot bend


Up to 300 mm dia. Kg MAT-07947 118.52
Above 300 mm dia. Kg MAT-07948 131.52

VIII DI All socket Cross.


Up to 300 x 300 mm dia. Kg MAT-07949 118.52
Above 300 x 300 mm dia. Kg MAT-07950 131.52

IX DI All Flange Tee


Up to 500 x 500 mm dia. Kg MAT-07951 118.52
Above 500 x 500 mm dia. Kg MAT-07952 131.52

X DI All Flange Cross


Up to 300 x 300 mm dia. Kg MAT-07953 118.52
Above 300 x 300 mm dia. Kg MAT-07954 131.52

93
Public Health Engineering Items

XI DI Double Flange Reducer


Up to 500 x 450 mm dia. Kg MAT-07955 118.52
Above 500 x 450 mm dia. Kg MAT-07956 131.52

XII Blank Flange


Up to 500 mm dia. Kg MAT-07957 118.52
Above 500 mm dia. Kg MAT-07958 131.52

XIII Mechanical Joints


Up to 300 mm dia. Kg MAT-07959 118.52
Above 300 mm dia. Kg MAT-07960 131.52

XIV DI Double Socket Bends


Up to 500mm dia. Kg MAT-07961 118.52
Above 500 mm dia. Kg MAT-07962 131.52

XV DI Double Flanged Bends


Up to 500mm dia. Kg MAT-07963 118.52
Above 500 mm dia. Kg MAT-07964 131.52

XVI DI Manhole Frame & cover Kg 118.52

94
Public Health Engineering Items

26. S o R FOR RUBBER GASKETS SUITABLE FORC.I/ D.I. S/S PIPES FOR THE
YEAR 2021-22

Sl. No. Description Unit Code Rate


1 2 3 4
Manufacture as per BIS: 12820/89 with S.B.R. Quality Rubber confirming to BIS:
5382/85, supply and delivery of Rubber Gaskets suitable for C.I/ D.I S/S pipes
anywhere in A.P. F.O.R. Destination departmental stores including cost of material,
1
loading, incidental handling with companies standard packing, transportation,
unloading & stacking but excluding all taxes.

80mm dia. Each MAT-07965 39


100mm dia. Each MAT-07966 61
125mm dia. Each MAT-07967 73
150mm dia. Each MAT-07968 89
200mm dia. Each MAT-07969 107
250mm dia. Each MAT-07970 120
300mm dia. Each MAT-07971 183
350mm dia. Each MAT-07972 231
400mm dia. Each MAT-07973 256
450mm dia. Each MAT-07974 299
500mm dia. Each MAT-07975 416
600mm dia. Each MAT-07976 525
700mm dia. Each MAT-07977 698
750mm dia. Each MAT-07978 823
800mm dia. Each MAT-07979 987
900mm dia. Each MAT-07980 1191
1000mm dia. Each MAT-07981 1303

95
27. SoR FOR CI PIPES AND SPECIALS FOR THE YEAR 2020-21

Rate/ Kg
including
packing,
forwarding,
Sl. Quality or Transit risk
Description Code
No. sort and delivery
anywhere in
A.P. for the
year 2021-
22 (Rs.)
1 Manufacture, Supply and Delivery of Cast Iron Pipes I.S. No.
and Fittings (spls.) Conforming to IS. No. 7181/1986
7181/1986, 5531/1988, 3950/1979 and C.I.D Joints 5531/1988
confirming to is No.8794/1988 at site of work 3950/1979 MAT-07982 70.94
anywhere in A.P. Including, loading, unloading, &
transportation to site of work stacking at site transit 8794/1988
risk and package, excluding taxes and duties.

Foot Note: The rate of CI pipes, CI Specials and CID Joints etc., which are to be incorporated in the
SoR are based on the following raw materials cost.
Pig Iron: Rs.38,000/- per M.T. (Excluding all taxes).
Coke : Rs.26,519/- per M.T. (Excluding all taxes).

The rates may be revised depending upon the increase/decrease in the cost of raw materials as per the
following method. For every increase/decrease of Rs.1000/- in the cost of raw materials or part there
of proportionately.
In respect of Pig Iron: The increase/decrease in cost of CI Specials per Kg is 3.43%.
In respect of coke: The increase/decrease in cost of CI Specials per Kg is 0.67%.

The above price is at site of work.


Note-1: The above formula for calculation of revised cost to be used for preparation of Estimates
only.

96
28. S o R FOR WATER HAMMER CONTROL DEVICES FOR THE YEAR 2021-22
(Rate Each in Rs.)

Sl.
Description
No. TEST PRESSURE
10 Kgs/cm2 15 Kgs/cm2 20 Kgs/cm2 25 Kgs/cm2
Manufacture, Supply and delivery of Air Cushion valves / Quick Released damped Air Valves
1 (QRDA) as per AWWA, Ex-factory excluding transportation and all taxes.

DIA. IN MM Code Rate/Each Code Rate/Each Code Rate/Each Code Rate/Each


MAT- 70689 MAT- 81294 MAT- 89422 MAT- 98361
100 07983 07986 07989 07992
MAT- 107425 MAT- 123539 MAT- 135892 MAT- 149481
150 07984 07987 07990 07993
MAT- 114661 MAT- 131858 MAT- 145046 MAT- 159550
200 07985 07988 07991 07994
Conveyance of
valves and
accessories
including
2 loading at 5% on basic cost of valves
factory and
unloading,
stacking at site
of work.

97
29. S o R FOR VALVES CONFORMING TO IS for normal usage 2021-22.

Sl.
Description
No.
Supply, Delivery of D.I double flanged Sluice Valves conforming to IS- 14846 (with up to
date amendments, if any) including gear arrangements for the following dia. as per test
pressure having Body, Bonnet, Dome, Stool cover, Wedge, Stuffing box, Gland, Thrust
plate, Cap/Hand wheel with D.I; Stem, Body seat ring, Wedge facing ring, Bushes, Bolts,
1 Nuts, Pinion and Pinion shaft with Stainless steel (IS 6603) ; Wedge nut, Shoe, Channel
with Leaded Tin Bronze ( IS 318 ); Gasket with Neoprene Rubber; Gland packing with
Rubber; Gear, Gear housing with Cast Steel excluding all taxes and transportation, etc.
complete ISI marked.
PN 1.0 (MPa) PN 1.6 (MPa)

DIA. IN MM Code Rate/Each Code Rate/Each


50 9720 12150
100 13088 14400
150 20607 21150
200 27280 34100
250 41580 47429
300 63580 71682
350 78980 98725
400 135080 168850
450 MAT-07995 168080 MAT-08004 210100
500 MAT-07996 210980 MAT-08005 263725
550 219780 274725
600 MAT-07997 270380 MAT-08006 337975
650 300080 375100
700 MAT-07998 520080 MAT-08007 650100
750 564080 705100
800 MAT-07999 674080 MAT-08008 842600
850 768680 960850
900 MAT-08000 875380 MAT-08009 1094225
1000 MAT-08001 1425380 MAT-08010 1781725
1100 MAT-08002 1645380 MAT-08011 2056725
1200 MAT-08003 1865380 MAT-08012 2331725
Supply, Delivery of D.I double flanged short/Long body or Wafer Type pattern Butterfly
Valves for the following dia. conforming to IS 13095 (with up to date amendments, if any)
2 manually operated having Body, Disc with D.I; Shaft, Seating ring, internal fastenings with
Stainless steel (IS: 6603); External bolting with Carbon steel; Seat with Nitrite or EPDM
rubber; excluding transportation and all taxes, complete.
DIA. IN MM Code PN 2.5 (MPa) (Rate/Each)

50 MAT-08013 14080

98
100 MAT-08014 16280
150 MAT-08015 23980
200 MAT-08016 43780
250 MAT-08017 49280
300 MAT-08018 56980
350 MAT-08019 69080
400 MAT-08020 100980
450 MAT-08021 132880
500 MAT-08022 190080
550 MAT-08023 210980
600 MAT-08024 234080
650 MAT-08025 270380
700 MAT-08026 328680
750 MAT-08027 344080
800 MAT-08028 369380
850 MAT-08029 388080
900 MAT-08030 438680
1000 MAT-08031 564080
1100 MAT-08032 674080
1200 MAT-08033 894080

Supply, Delivery of D.I Double Flanged Swing Check type Reflux valves (Non Return
Valves) of following dia. conforming to IS- 5312 (Pts-1&2) (with amendments up to date,
if any) having Body, Cover, Door, Bearing holder with D.I; Hinge pin, Door pin, Door
3 suspension pin with Stainless Steel (IS 6603); Body seat ring , Door face ring, Bearing
bushes, Plugs for hinge pin with Leaded Tin Bronze ( IS 318 ); Bolts, Nuts with Carbon
steel; Gaskets with Rubber; Hinges with Cast steel; excluding transportation and all taxes
complete.
PN 1.0 (MPa) PN 1.6 (MPa)
DIA. IN MM Code Rate/Each Code Rate/Each
50 MAT-08034 10780 MAT-08046 13475
100 MAT-08035 15180 MAT-08047 18975
150 MAT-08036 21780 MAT-08048 27225
200 MAT-08037 29480 MAT-08049 36850
250 MAT-08038 40480 MAT-08050 50600
300 MAT-08039 62480 MAT-08051 78100
350 MAT-08040 74580 MAT-08052 93225
400 MAT-08041 89980 MAT-08053 112475
450 MAT-08042 116380 MAT-08054 145475
500 MAT-08043 192280 MAT-08055 240350
550 MAT-08044 212080 MAT-08056 265100

99
600 MAT-08045 256080 MAT-08057 320100
Conveyance of valves and 5% on basic cost of valves
accessories including
4 loading at factory and
unloading, stacking at site
of work.

100
30. S o R FOR VALVES FOR HEAVY USUAGE in WTPS, STPS, PUMP HOUSES,
PUMPING MAINS & ELSRS 2021-22.

Sl.
No Description
. TEST PRESSURE
Supply and delivery of "Resilient Seated Soft Sealing" Gate Valves (Sluice Valves) with Body and
Bonnet of Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865,
IS:3896-2 and Wedge fully Rubber Lined with food grade quality grade W270 grade EPDM,
Replaceable Spindle Nut without gland packing with 3-O ring protection system on the Shaft and
1 Seals of NBR. The Valves should be Vacuum tight and 100% leak proof with face to face dimensions
as BS:5163 Type A/IS:14846. All the valves should be with fusion bonded Electrostatic Powder
coating both inside and outside (Min 250 Microns)- RAL 5005 with Pocket Less Straight through
body Passage conforming to Design standards of DIN-3202F4/BS:5163 Type A Flange drilling as per
IS - 1538 excluding all taxes, duties and transportation.
DIA. IN PN 1.0 (MPa) PN 1.6 (MPa) PN 2.5 (MPa)
MM
A) Without Rate/Eac Rate/Eac
Code Code Code Rate/Each
By-Pass h h
50 MAT-08058 7669 MAT-08067 7669 MAT-08076 13865
80 MAT-08059 9922 MAT-08068 9922 MAT-08077 17094
100 MAT-08060 11880 MAT-08069 12957 MAT-08078 19381
150 MAT-08061 18480 MAT-08070 20401 MAT-08079 32327
200 MAT-08062 23980 MAT-08071 29975 MAT-08080 54524
250 MAT-08063 30580 MAT-08072 38225 MAT-08081 80987
300 MAT-08064 56980 MAT-08073 70965 MAT-08082 131363
350 MAT-08065 78980 MAT-08074 98725 MAT-08083 384409
400 MAT-08066 100980 MAT-08075 126225 MAT-08084 390996
B) With By-
Pass
450 165880 207350
500 212080 265100
550 234080 292600
600 300080 375100
650 344080 430100
700 432080 540100

Supply & Delivery of Tamper Proof DI Flanged Single Chamber Air Release Valves with body &
cover made of Ductile Iron Grade GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per
IS1865, IS:3896-2 with Food Grade Epoxy Powder Coating(EP-P) (Min:250 Micron) inside and
2 Outside of Color Blue RAL 5005. All internal parts such as Float, shell, Cove Bolts etc. made of
Austenitic alloy steel of SS AISI 304/316 and DN 50 float of and other components with
ABS/PTFE/EPDM/NBR and generally conforming to DIN/BIS/AWWA standards (or) combination
Flange drilling as per IS - 1538 and exclusive of all taxes and transportation.
PN 1.0 PN 1.6
DIA. IN (MPa) (MPa) PN 2.5 (MPa)
Code Code Code
MM Rate/Eac Rate/Eac Rate/Each
h h

101
25 MAT-08085 4180 MAT-08093 5225
40 MAT-08086 7480 MAT-08094 9350 MAT-08101 53890
50 MAT-08087 10780 MAT-08095 13475 MAT-08102 44092
80 MAT-08088 18480 MAT-08096 23100 MAT-08103 45715
100 MAT-08089 23980 MAT-08097 29975 MAT-08104 61378
150 MAT-08090 45980 MAT-08098 57475 MAT-08105 74257
200 MAT-08091 66538 MAT-08099 66538 MAT-08106 82766
300 MAT-08092 108680 MAT-08100 111150
Manufacture, Supply and delivery of DI D/F Tilting disc Swing Check Valves Slanted seated with
maximum swing of 59 degree with metallic, corrosion proof and wear resistant seat faces, Body and
Disc of ductile cast iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865,
IS:3896-2 Shafts of stainless steel, shaft bearing of zinc free bronze and Integral body seat face & disc
3 face with nickel-chromium overlay welding and micro finished. All the inside and outside of the body
is to be coated with double coating of food grade epoxy liquid lacquer (EP-F) with minimum
thickness of 150 microns, color: RAL 5005 Blue face to face dimensions according to EN 558-
1/14/DIN 3202-F4, Flange dimensions according to EN1092-2/IS 1538

DIA. IN
PN 1.0 (MPa) PN 1.6 (MPa) PN 2.5 (MPa)
MM
a)Without Rate/Eac
Code Code Rate/Each Code Rate/Each
By-Pass h
MAT-08107 11880 MAT- 14850 MAT-08139 23760
80 08123
MAT-08108 16280 MAT- 20350 MAT-08140 32560
100 08124
MAT-08109 21780 MAT- 27225 MAT-08141 43560
150 08125
MAT-08110 27280 MAT- 34100 MAT-08142 54560
200 08126
MAT-08111 39380 MAT- 49225 MAT-08143 78760
250 08127
MAT-08112 56980 MAT- 71225 MAT-08144 113960
300 08128
b)With By-
Pass
MAT-08113 67980 MAT- 84975 MAT-08145 135960
350 08129
MAT-08114 104280 MAT- 130350 MAT-08146 208560
400 08130
MAT-08115 135080 MAT- 168850 MAT-08147 270160
450 08131
MAT-08116 149380 MAT- 186725 MAT-08148 298760
500 08132
MAT-08117 168080 MAT- 210100 MAT-08149 336160
550 08133
MAT-08118 206580 MAT- 258225 MAT-08150 413160
600 08134
MAT-08119 248380 MAT- 310475 MAT-08151 496760
650 08135
700 MAT-08120 303380 MAT- 377520 MAT-08152 606760

102
08136
MAT-08121 328680 MAT- 410850 657360
750 08137
MAT-08122 369380 MAT- 461725 738760
800 08138
850 388080 485100 776160
900 438680 548350 877360
1000 548680 685850 1097360
1100 850850 935935
1200 1100000 1210000
Manufacture, Supply and delivery of DI D/F Butterfly Valves, Body and disc of Ductile Iron of grade
GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 Double
eccentrically designed Disc., with renewable soft seal on the disc and Integral Body seat face of
nickel-chromium overlay welding (Fusion Bonded) micro finished, 100 % leak tight in both
4 directions, Medium free bearings and with minimum thickness of 250 microns Fusion bonded food
grade epoxy coating and 1200mm dia. and above food grade liquid Epoxy coating of minimum 150
microns applied on both body and disc inside and outside. Face to face dimensions as per EN558-1/IS
13095 body or IS: 13095 long body design standard as per EN 593/IS 5163 Flange drilling as per EN
1092-2/ IS 1538 the Valve should be suitable for buried application.
PN 4.0
DIA. IN PN 1.0 PN 1.6 PN 2.5
Code Code Code (MPa)
MM (MPa) (MPa) (MPa)
Code
MAT-08153 19580 MAT- 24475 MAT- 39160 MAT- 146478
150 08173 08193 08213
MAT-08154 27280 MAT- 34100 MAT- 54560 MAT- 178108
200 08174 08194 08214
MAT-08155 38280 MAT- 47850 MAT- 76560 MAT- 249581
250 08175 08195 08215
MAT-08156 47080 MAT- 58850 MAT- 94160 MAT- 262068
300 08176 08196 08216
MAT-08157 65780 MAT- 82225 MAT- 131560 MAT- 285236
350 08177 08197 08217
MAT-08158 87780 MAT- 109725 MAT- 175560 MAT- 436082
400 08178 08198 08218
MAT-08159 98780 MAT- 123475 MAT- 197560 -
450 08179 08199
MAT-08160 127380 MAT- 159225 MAT- 254760 MAT- 538878
500 08180 08200 08219
550 149380 186725 298760
MAT-08161 168080 MAT- 210100 MAT- 336160 MAT- 590468
600 08181 08201 08220
650 190080 237600 380160
MAT-08162 218680 MAT- 273350 MAT- 437360
700 08182 08202
750 248380 310475 496760
800 MAT-08163 279180 MAT- 348975 MAT- 558360
08183 08203
850 300080 375100 600160
900 MAT-08164 328680 MAT- 410850 MAT- 657360
08184 08204

103
1000 MAT-08165 454080 MAT- 567600 MAT- 908160
08185 08205
1100 MAT-08166 674080 MAT- 842600 MAT- 1348160
08186 08206
1200 MAT-08167 784080 MAT- 980100 MAT- 1568160
08187 08207
1300 1004080 1255100 2008160
MAT-08168 1098680 MAT- 1373350 MAT- 2197360
1400 08188 08208
1500 1379180 1723975 2758360
MAT-08169 1367080 MAT- 1708850 MAT- 2734160
1600 08189 08209
1700 1928080 2410100 3856160
MAT-08170 2116180 MAT- 2645225 MAT- 4232360
1800 08190 08210
1900 2399980 2999975 4799960
MAT-08171 2547380 MAT- 3184225 MAT- 5094760
2000 08191 08211
2100 2662880 3328600 5325760
MAT-08172 2838880 MAT- 3548600 MAT- 5677760
2200 08192 08212
Supply delivery of Double Flanged Slant seat Swing Check Valve (NRV) with body and Disc of
Ductile Iron GGG-40/SG-400/15 or GGG-50/SG-500/7 or Equivalent as per IS1865, IS:3896-2 with
fully encapsulated in Vulcanized EPDM rubber & Fusion bonded Electro Static epoxy powder coating
5 inside and outside color Blue RAL 5005 with Min. Coating thickness of 250 microns. The EPDM
rubber & Epoxy rubber & Epoxy powder should conform to W 270 standards (Drinking water
application) and face to face dimensions as per EN 558-1 / DIN 3202-F6 / IS 5312 & Flange
connections as per IS:1538 excluding all duties, taxes and transportation.
DIA. IN
PN 1.0 (MPa) PN 1.6 (MPa) PN 2.5 (MPa)
MM
a)Without Rate/Eac
Code Code Rate/Each Code Rate/Each
By-Pass h
80 13514 14865
100 18480 23100
150 27280 34100
200 32780 40975 167578
250 43780 54725 203526
300 54780 68475 247771
b)With By-
Pass
350 78980 98725
400 96580 120725
450 107580 134475
500 149380 186725
550 182380 227975
600 218680 273350

104
NOTE:-1) All the prices are ex-go down /ex-factory. Packaging and Transportation extra at 5% on
basic cost. The grade of DI & conformation to specifications shall be certified by a third party Quality
Control Agency approved by indenting authority at the cost of supplier.

105
31. S o R FOR SFRC MAN-HOLE FRAME WITH COVERS FOR THE YEAR 2021-22.

Sl. No. Description Unit Code Rate


Manufacture as per BIS:12592 (Part 1&2) Supply & Delivery of manhole covers
I and frames with ISI marking anywhere in A.P., F.O.R. destination including,
loading, un-loading & stacking at site but excluding all taxes.
a) M.D. -10 with 500mm dia. Clear opening Each MAT-08221 1543.00
b) H.D.-20 with 500mm dia. Clear opening Each MAT-08222 1989.00
H.D.-10with 560mmdia. clear opening(New Each MAT-08223
C) 1560.00
item)
d) H.D.-20 with 560mm dia. Clear opening Each MAT-08224 2133.00
e) H.D.-35 with 560mm dia. Clear opening. Each MAT-08225 2286.00
f) 24x24 MD 10 Each MAT-08226 1682.00
g) 24x18 MD 10 Each MAT-08227 1548.00
h) 24x24 HD 20 Each MAT-08228 1890.00
i) 24x18 HD 20 Each MAT-08229 1927.00
j) Dividers 0.9 Mtr. Each MAT-08230 3957.00

Manufacture as per company’s standard


specification supply and delivery of
encapsulated plastic steps for man holes MAT-08231
II anywhere in A.P. including cost of materials Each 166.00
packing as per company’s standards, loading,
transportation, unloading and stacking at site
of work etc, complete but excluding all taxes.

106
32. S o R FOR CI and M.S. DISMANTLING JOINTS FOR THE YEAR 2021-22

Sl.No. Description Unit Code Rate


Manufacture, Supply and Delivery of C.I Dismantling Joints with both side flange
1 end suitable for installation in between flange end pipes. These rates are excluding
all taxes.
Nominal Dia. In MM
50 Each MAT-08232 4826
80 Each MAT-08233 5282
100 Each MAT-08234 6900
125 Each MAT-08235 8800
150 Each MAT-08236 9777
200 Each MAT-08237 13864
250 Each MAT-08238 16504
300 Each MAT-08239 26409
Manufacture, Supply and Delivery of M.S. Dismantling Joints with both side flange
2 end suitable for installation in between flange end pipes. Thickness as per IS: 7322.
These rates are excluding all taxes.
Nominal Dia. In MM
350 Each MAT-08240 59,785
400 Each MAT-08241 68,507
450 Each MAT-08242 74,325
500 Each MAT-08243 88,959
600 Each MAT-08244 1,03,515
700 Each MAT-08245 1,15,161
750 Each MAT-08246 1,18,075
800 Each MAT-08247 1,41,365
900 Each MAT-08248 1,47,482
1000 Each MAT-08249 1,76,660
1100 Each MAT-08250 1,91,245
1200 Each MAT-08251 2,20,420
1300 Each MAT-08252 2,49,592
1400 Each MAT-08253 2,79,334
1600 Each MAT-08254 3,08,566
1800 Each MAT-08255 3,65,405
2000 Each MAT-08256 4,54,730
Conveyance of joints and accessories including 5% on basic cost
3 loading at factory and unloading, stacking at site of
work.

107
33. OTHER ITEMS FOR THE YEAR 2021-22

Sl.
Description Unit Code Rate
No.

1 2 3 4 5
MAT-08257
SUPPLY AND DELIVERY OF PIG LEAD
1 99.99 % PURE INCLUDING TAXES AND Per Kg 287
CONVEYANCE ETC., COMPLETE.
MAT-08258
SUPPLY AND DELIVERY OF LEAD WOOL
2 BEST QUALITY INCLUDING TAXES AND Per Kg 168
CONVEYANCE ETC., COMPLETE.
MAT-08259
SUPPLY AND DELIVERY OF SPUN YARN 116
3 OF BEST QUALITY INCLUDING TAXES Per Kg
AND CONVEYANCE ETC., COMPLETE.

SUPPLY AND DELIVERY OF RUBBER


4 PACKING INCLUDING TAXES AND
CONVEYANCE ETC., COMPLETE.
a) 3 mm thick Per Kg MAT-08260 93
b) 6 mm thick Per Kg MAT-08261 93
MAT-08262
SUPPLY AND DELIVERY OF BOLTS AND
NUTS WITH DOUBLE WASHERS
5 Per Kg 111
INCLUDING TAXES AND CONVEYANCE
ETC., COMPLETE. (1/2" TO 1")

108
34. S o R FOR TRENCH LESS TECHNOLOGY WITH PIPE JACKING METHOD FOR
THE YEAR 2021-22

Sl.
Description Unit Code Rate
No.

Railway crossing/Road crossing/Canal crossing by adopting trenchless technology


tunneling work through specialized pipe jacking method by erecting the equipment to true
to the alignment and gradient, by hydraulic pipe jacking technique complete including
1 tunneling, excavation in all types of soils including hard rock and construction of RCC
chambers suitable to casing pipe pits, and conveyance charges of machinery and other
required materials but excluding cost of encasing pipe, in co-ordination with the concerned
authorities as per approved drawings and directed by the Engineer-in –Charge.
800 mm dia. Rmt MAT-08263 27300.00
900 mm dia. Rmt MAT-08264 28665.00
1000 mm dia. Rmt MAT-08265 30030.00
1100 mm dia. Rmt MAT-08266 31395.00
1200 mm dia. Rmt MAT-08267 32760.00
1300 mm dia. Rmt MAT-08268 34125.00
1400mm dia. Rmt MAT-08269 36855.00
1500 mm dia. Rmt MAT-08270 40950.00

109
35.S o R FOR HOUSE SERVICE CONNECTIONS FOR THE YEAR 2021-22

Sl. Description Unit Code Rate


No.
1 House service connections (Compression Fittings)
Supply and Fixing of compression fittings shall comply with ISO 17885 2015, PN-16 rating
and manufactured from virgin resin of PE-80 having blue color. Raw material must be WRAS
approved as per BS 6920 for effect on water quality intended for human consumption.
Compression fittings should have moulded in SS 304 threaded insert outlet with thread
dimension confirming to IS 554/ISO 7. The cost shall include testing of all materials, labor all
taxes (central and state), inspection charges, transportation up to site, transit insurance,
loading, unloading, stacking and fixing etc, complete as specified and directed by the
departmental Engineer in charge.
Compression male/female threaded adaptor with Each MAT-08296 165
SS insert D20 mm X 1/2 "
Compression male/female threaded adaptor with Each MAT-08297 203
SS insert D25 mm X 3/4 "
Compression male/female threaded adaptor with Each MAT-08298 306
SS insert D32 mm X 1 "
Compression male/female threaded elbow with Each MAT-08299 176
SS insert D20 mm X 1/2 "
Compression male/female threaded elbow with Each MAT-08300 226
SS insert D25 mm X 3/4 "
Compression male/female threaded elbow with Each MAT-08301 336
SS insert D32 mm X 1 "
Double Compression elbow 20 mm 64 Each MAT-08302 72
Double Compression elbow 25 mm 79 Each MAT-08303 89
Double Compression elbow 32 mm Each MAT-08304 126
2 House service connections (Composite strap saddle for DI/CI pipes)
Supply and fixing of composite strap saddle shall be of wrap around design pN-16 rating.
Body shall be manufactured using virgin compounded PE 80/PE 100 polymer with stainless
steel 304 grade stirrup plate mounted with PE straps (Engineering Plastic) with Nut bolt joint,
sealing between the saddle and mains shall be obtained by using an elastomer seal
(Underneath projection for self interlocking). The cost shall include testing of all materials,
labor all taxes (central and state), inspection charges, transportation up to site, transit
insurance, loading, unloading, stacking and fixing etc, complete as specified and directed by
the departmental Engineer in charge.
(Main pipe outer diameter in mm & tapping size
in inches)
100 x 1/2" Each 685
100 x 3/4" Each 709
100 x 1" Each 860
150 x 1/2" Each MAT-08305 979
150 x 3/4" Each MAT-08306 1018
150 x 1" Each MAT-08307 1162
200 x 1/2" Each MAT-08308 1034

110
200 x 3/4" Each MAT-08309 1139
200 x 1" Each MAT-08310 1185
3 House service connections (Regulating Brass ferrule)
The cost shall include testing of all materials, labor all taxes (central and state), inspection
charges, transportation up to site, transit insurance, loading, unloading, stacking and fixing
etc, complete as specified and directed by the departmental Engineer in charge.

1/2" Each MAT-08311 182


3/4" Each MAT-08312 300
1" Each MAT-08313 523
4 House service connections (PP Saddle) PP
Clamp saddles-PP clamp Saddles shall be
maunfactured by injection moulding using
virgin polypropylene. Mechanical tapping
saddles for water works purposes and
designed for use with PVC/PE pipe as per IS
4985/IS 4984 respectively. These saddles
should be contoured to fit around the pipe. PP
saddles shall be Blue/Black moulded-in with
Nickel plated Brass / SS 304 metal female
threaded outlets. Seal shall be thermoplastic
elastomer rubber suitable for drinking water
and nut-bolt-washer with SS. The PP Clamp
saddle fittings shall be moulded with SS
304/Nickel plated Brass female threaded outlet
inserted to connect necessary fittings. Thread
dimension shall conform to IS-554/ISO-7.
Adequate thickness of PP shall be provided to
hold brass insert in place and avoid leakage
while pressure applications. Fasteners shall be
threaded type, with SS. Fasteners of size
125mm and above. The grade of raw material
used must be certified by WRAS, UK for type
test as per BS 6920 from their certified
laboratories like NSF International Ltd. UK
and certificate of Compliance to be produced
for the following parameters: i) Odiur &
Flavour of water ii) Appearance of water iii)
Growth of Micro Organism iv) Extraction of
Substances that may be of concern to public
health (Cyto toxicity) v) Extraction of Metals
(Main pipe outer diameter in mm & tapping size
in inches)
63x1/2" Each MAT-08314 800
63x3/4" Each MAT-08315 800
63x1" Each MAT-08316 800
75x1/2" Each MAT-08317 800
75x3/4" Each MAT-08318 800

111
75x1" Each MAT-08319 800
90x1/2" Each MAT-08320 800
90x3/4" Each MAT-08321 800
90x1" Each MAT-08322 800
110x1/2" Each MAT-08323 800
110x3/4" Each MAT-08324 800
110x1" Each MAT-08325 800
125x1/2" Each MAT-08326 800
125x3/4" Each MAT-08327 800
125x1" Each MAT-08328 800
140x1/2" Each MAT-08329 800
140x3/4" Each MAT-08330 800
140x1" Each MAT-08331 800
160x1/2" Each MAT-08332 800
160x3/4" Each MAT-08333 800
160x1" Each MAT-08334 800
180x1/2" Each MAT-08335 954
180x3/4" Each MAT-08336 954
180x1" Each MAT-08337 954
200x1/2" Each MAT-08338 954
200x3/4" Each MAT-08339 954
200x1" Each MAT-08340 954
5 Supply and Fixing of Meter Box / Valve box is
recommended to encompass & protect Water
meters/valves installed on drinking water supply
pipes. Meter Box manufacturers must have ISO
9001, ISO 14001 and ISO 18001 certification for
their QMS, EMS & OHSAS systems. Meter Box
should be of two components, comprising body
and lid. Provision for embossed marking on the
lid as per customer requirement, Nominal Size of
box should be 8” X 12” with Rectangular shape
,Minimum Dimensions: Length 355mm x height
180mm x width 270mm,Locking: with Built in
lock.
METER BOX 8X12 WITH BUILT IN LOCK, Each 450
Note: For Item No.35 (1 to 5).
(A) The above rates are including taxes of 18% GST. The same may be deducted for obtaining
basic rates.
(B) The rates for estimate purpose may be compared with market rates by quotations and may
be adopted by considering which ever is less.

112
36. SoR FOR ARC WELDED M.S PIPE FOR THE YEAR 2021-22

Manufacture, supply and delivery of submerged ARC welded M.S Pipe having beveled ends
from plate or coil conforming to IS-3589 and/or IS-5504 with its latest revision / amendment
with inside 406 micron thick food grade epoxy coating and outside 3LPE coating conforming to
DIN 30670 / Polyolefin Tape coating conforming to AWWA C214 for the specified thickness &
inner diameter of pipe, external field joint coating with polyolefin backing and internal field
joint coating with chemically cured 2 part epoxy based solvent free liquid coating material for
Drinking Water NSF approved etc., complete including all labour, materials and ROU/ROW as
per specification and to the satisfaction of Engineer-in-charge excluding transportation and
GST.
Inner Outer Thickness Code MS Pipe Code MS Pipe
Diameter Diameter (mm) Rate with Rate with
(mm) (mm) Internal Internal
406 micron 406 micron
thick food thick food
grade grade
epoxy epoxy
coating and coating and
3LPE Polyolefin
coating Tape
conforming coating
to DIN conforming
30670 to AWWA
C214
500 510 5 MAT-08344 5723 MAT-08408 5634
500 511.20 5.60 MAT-08345 6165 MAT-08409 6084
500 512.60 6.30 MAT-08346 6681 MAT-08410 6600
500 522 11 MAT-08347 10186 MAT-08411 10104
600 611.60 5.80 MAT-08348 7558 MAT-08412 7462
600 612.60 6.30 MAT-08349 7998 MAT-08413 7902
600 625 12.50 MAT-08350 13522 MAT-08414 13424
700 712.60 6.30 MAT-08351 9285 MAT-08415 9204
700 714.20 7.10 MAT-08352 10101 MAT-08416 10024
700 728.40 14.20 MAT-08353 17422 MAT-08417 17390
800 814.20 7.10 MAT-08354 11526 MAT-08418 11440
800 816 8 MAT-08355 12573 MAT-08419 12494
800 836 18 MAT-08356 24369 MAT-08420 24365
900 916 8 MAT-08357 14125 MAT-08421 14040
900 917.60 8.80 MAT-08358 15172 MAT-08422 15093
900 920 10 MAT-08359 16745 MAT-08423 16677
900 935 17.50 MAT-08360 26672 MAT-08424 26669
1000 1017.60 8.8 MAT-08361 16837 MAT-08425 16752
1000 1020 10 MAT-08362 18581 MAT-08426 18508
1000 1040 20 MAT-08363 33269 MAT-08427 33296
1050 1067.60 8.80 MAT-08364 17670 MAT-08428 17583
1050 1070 10 MAT-08365 19499 MAT-08429 19423
1050 1072 11 MAT-08366 21026 MAT-08430 20961
1100 1117.6 8.8 MAT-08367 18587 MAT-08431 18412

113
1100 1120 10 MAT-08368 20515 MAT-08432 20339
1100 1122 11 MAT-08369 22124 MAT-08433 21947
1200 1220 10 MAT-08370 22362 MAT-08434 22170

1200 1222 11 MAT-08371 24114 MAT-08435 23922


1200 1225 12.50 MAT-08372 26748 MAT-08436 26556
1300 1325 12.50 MAT-08373 28952 MAT-08437 28744
1300 1328.40 14.20 MAT-08374 32189 MAT-08438 31980
1400 1425 12.50 MAT-08375 31155 MAT-08439 30931
1400 1428.40 14.20 MAT-08376 34634 MAT-08440 34410
1500 1528.40 14.20 MAT-08377 37082 MAT-08441 36841
1500 1532 16 MAT-08378 41031 MAT-08442 40792
1600 1628.40 14.20 MAT-08379 39528 MAT-08443 39274
1600 1632 16 MAT-08380 43733 MAT-08444 43480
1700 1728.40 14.20 MAT-08381 41973 MAT-08445 41705
1700 1732 16 MAT-08382 46435 MAT-08446 46169
1700 1735 17.50 MAT-08383 50160 MAT-08447 49898
1800 1828.40 14.20 MAT-08384 44419 MAT-08448 44137
1800 1832 16 MAT-08385 49137 MAT-08449 48859
1800 1835 17.50 MAT-08386 53077 MAT-08450 52801
1900 1932 16 MAT-08387 51839 MAT-08451 51548
1900 1935 17.50 MAT-08388 55993 MAT-08452 55704
1900 1940 20 MAT-08389 62930 MAT-08453 62646
2000 2032 16 MAT-08390 54542 MAT-08454 54236
2000 2035 17.50 MAT-08391 58909 MAT-08455 58608
2000 2040 20 MAT-08392 66203 MAT-08456 65907
2100 2135 16 MAT-08393 61826 MAT-08457 61512
2100 2140 17.50 MAT-08394 69476 MAT-08458 69169
2100 2144.40 20 MAT-08395 76224 MAT-08459 75921
2200 2235 17.50 MAT-08396 64742 MAT-08460 64415
2200 2240 20 MAT-08397 72750 MAT-08461 72429
2200 2244.40 22.20 MAT-08398 79811 MAT-08462 79498
2300 2340 20 MAT-08399 76023 MAT-08463 75691
2300 2344.40 22.20 MAT-08400 83399 MAT-08464 83074
2300 2350 25 MAT-08401 92806 MAT-08465 92489
2400 2440 20 MAT-08402 79296 MAT-08466 78951
2400 2444.40 22.20 MAT-08403 86986 MAT-08467 86648
2400 2450 25 MAT-08404 96793 MAT-08468 96465
2500 2540 20 MAT-08405 82569 MAT-08469 82213
2500 2544.40 22.20 MAT-08406 90573 MAT-08470 90224
2500 2550 25 MAT-08407 100780 MAT-08471 100441

114
37. SoR FOR HDPE ELECTRICAL PIPE CONDUITS FOR THE YEAR 2021-22
Supply of the HDPE Electrical pipe conduits with permanent Lubricant inner layer
with ribs , dimensional ratio of 13.5, deflection not greater than 5% when exposed to
the normal operating temperature 90 degrees centigrade under the overburden soil
pressure and other physical properties confirming to ASTMF 2160 and / or NEMA
TC 7 ( The expected service life of HDPE Pipe conduit and accessories shall not be
less than 50 years)including transportation and excluding GST
Diameter Code Rate per Rmt
160 mm MAT-08472 1221
200 mm MAT-08473 1981
225mm MAT-08474 2902
7 way ( Multi duct for ICT) MAT-08475 955

115
38. SoR FOR BORE WELL DRILLING RATES FOR THE YEAR 2021-22

S.No Type of Bore Well Rate in Rs.

1 Drilling of Bore well with DTH Rig per RM


Drilling of Bore well by down the hole hammer drilling to a finished dia
of 112/165 mm dia in all formations suitable for down the hole hammer
drilling such as medium hard rock formation to hard rock formation, all
consolidated formation etc. and drilling in over burden to dia not less
than 200 mm etc and reaming the bore well to suit insertion of suitable
casing pipe etc., including insertion of casing pipe with couplings, caps
any other relevant materials upto required depth as directed by the
department including transportation of drilling rigs and supporting
vehicle and including bore development (Flushing of Bore Well at an
average pressure of 150 PSI) conducting yield test, consumables
charges, Crew charges required in fixation of pipe assembly completely
done to the satisfaction of the department and including all labour
charges but excluding all taxes, the cost of casing pipe, couplings, cap
etc., The entire work should be carried out as per IS -2800 Part I & II
1979 and amended from time to time.
Drilling of Bore well 112 mm dia. up to 150.00 m depth 366
Drilling of Bore well 112 mm dia. beyond 150.00 m depth 418
Drilling of Bore well 112 mm dia for Agency area 10% over plain
area rates.
Drilling of Bore well 165 mm dia. up to 90.00 m depth 470
Drilling of Bore well 165 mm dia. above 90.00 m up to 150.00 m depth 502
Drilling of Bore well 165 mm dia. above 150.00 m up to 250.00 m depth 563
Drilling of Bore well 165 mm dia. above 250.00 m to 350.00 m depth 685
Drilling of Bore well 165 mm dia. beyond 350.00 m depth 740
Drilling of Bore well 165 mm dia for Agency area 10% over plain
area rates.
2 Drilling of Bore well with Rotary Rig per RM
Drilling of Bore hole (which may be carried out by pilot bore hole) to a
finished dia of 200/225/300 /350/450 mm hole (for insertion of
110/140/160/180/200mm PVC Pipe / 175/200mm PVC Blue casing
pipe) by Rotary drilling rig in all formations suitable for Rotary drilling
such as alluvium, Loamy, clayey, sandy, burried channels, highly
disturbed and bouldary zones high sheared and fractured zones followed
by jointed to massive soft, medium rock, all formations typical and
suitable for rotary drilling etc. including insertion of casing pipe ,
couplings, cap, plug fixation, and including filling the peripheral gap
with rebullied pebbled gravel packing, bore development, conducting
yield test, and all other required in the fixation of pipes assembly etc.
but excluding the cost of casing pipe, couplings, dummys, clamps etc.,
as recommended by the departmental Geologist. The bore should be
developed with compressor air until clear water free from sand and other
materials continuously discharged. The size of gravel used for gravel
packing should be as per ISI specification used for rotary tube well. The

116
pebbled gravel packing should be carried out in such a way that the
theoritical quantity consumed completely.
The entire work to be carried out as per I.S. 2800 Part - I & II of 1979
and including cost of all materials and all labour charges and excluding
all taxes etc.,
Drilling of Bore well of 200/225/300 mm dia for insertion of pipe dia of 1050
100/125 mm
Drilling of Bore well 350/450mm dia for insertion of pipe dia of 1360
160/175/200 mm
Drilling of Bore wells for Agency area 10% over plain
area rates.
3 Drilling of Bore Wells with Hand Bore Set per RM
Drilling of Bore well with Hand Bore set to a finished dia of
112/165/175/180 mm justify both sides in all kinds of formations
suitable for hand bore set drilling such as black cotton soils, sandy and
alluvial soils and insertion of PVC/PVC blue casing pipe with couplings
including slotting of pipe where ever required and fixing of bore well
with cap and bail plug as per directions of the department for a finished
item of work including conducting yield test, crew charges, cost of
consumables, transportation charges and bore development charges and
all other charges required in fixation of pipe assembly, Flushing of bore
with required pressure excluding cost of all required materials such as
cap, bail plug, clamp sets, bolts and nuts etc., excluding all taxes , cost
of PVC casing pipe, slotting charges.
Drilling of Bore well of finished dia of 112 mm 422
Drilling of Bore well of finished dia of 112 mm for Agency 10% over plain
area rates.
Drilling of Bore well of finished dia of 165/175/180 mm 605
Drilling of Bore well of finished dla of 165/175/180 mm for Agency 10% over plain
area area rates.
4 Construction of bore well platform
Construction of bore well platform of 1.85 m dia and 3.00 m length
drain and foot rest of 1.00 x LOU m with CC (1:2:4) using 20 mm H8G
metal including cost and conveyance of all materials labour charges,
centering, curing, seigniorage charges & excluding taxes etc., complete
as per UNICEF type design.
For Plain Areas per 1No 9240
For Agency Areas per 1No 10% over plain
area rates.
5 Flushing of bore well
Flushing of bore well of dia 165/150 mm with power rig at an average
pressure of 150 PSI, including crew charges, completely done to the
satisfaction of the department including detachable of all accessories
and refix all materials as per the original condition including all labour
charges, but excluding cost of materials & excluding taxes etc,,
complete,
for 112 mm dia Bore wells per 1 Job 8400
for 165/150 mm dia Bore wells per 1 Job 9975
For Agency Areas 10% over plain

117
area rates.
6 Deepening of existing bore wells
Deepening of existing bore wells of dia 165/150mm by using DTH rig
including flushing the bore well, conducting yield test etc. excluding
taxes.
for depth up to 150 mm per RM 552
for depth from 150 mm to 250mm per RM 630
for depth from 250 mm to 350mm per RM 767
above 350 mm depth per RM 830
7 Supply, Delivery of ISI marked fully hot dipped galvanized deep well
Inida Mark-H Hand Pump assembly complete unit with 10 Nos of
connecting rods (bright bar of 12mm dia and 100 mts length each
confirming to IS 9301/1990 & IS 14101 to 14104:1994 with their
amendments / revisions but excluding taxes.
Indian Mark -II Hand Pump Assembly Set 11445
8 Labour charges for erection of IM-II Hand Pump Assembly with all
its accessories and with the required number of 32mm dia CI-13 GI
pipes including all taxes and as per the directions of the department
officers but excluding taxes.
For Plain area 1050
For Agency area 10% over plain
area rates.
9 Casing Pipes and Bore caps excluding taxes
Cost and supply of 175 mm dia PVC blue casing pipe per RN3 1155
Slotting charges for 175 mm dia PVC blue casing pipe per RM 368
180 mm dia PVC Casing pipe perforation charges per RM 342
175 mm dia MS Casing pipe perforation charges per RM 415
Supply & Fixing of 180 mm dia PVC Bore Cap per 1No 315
10 Geological Survey Charges excluding taxes.
for plain area-1 Job 1300
for Agency area-1 Job 10% over plain
area rates.
11 32mm dia GI B-Class pipes per RM
for 32mm dia GI B-Class pipes per RM 420

118
GOVERNMENTOFANDHRAPRADESH

BUILDINGSSoR:2021-22
SCHEDULE OF RATES
FOR
BUILDINGSWORKS

FOR THE YEAR 2021-22

ALL ENGINEERING DEPARTMENTS

i
Office of the Engineer-In-Chief (R&B) Buildings& RSW
Convener-Member,
Committee of Chief Engineers-Buildings-SoR

Procs.No. 20938/SOR/DCE(B)/EE(B)/DEE(B)/AEE/2021, Dt. 19.07.2021

Sub:- Printing of Buildings-SoR for all the Engineering Departments specific to the
functioning of Building works – Buildings-SoR:2021-22 – Communication of
Buildings-SoR – Reg.,

Ref:- 1. G.O.Rt.No.95, T, R&B (R.1) Dept, dt:18.01.2015.


2. Minutes of Committee of Chief Engineers meetings for finalizing the
Building-SoRs held on 09.03.2021,31.03.2021,20.04.2021, 28.06.2021
and 15.07.2021

*****
The Government of Andhra Pradesh have constituted a Committee of Engineer -in-Chiefs
/Chief Engineers of Engineering departments dealing with Building works for finalizing and
communicating Buildings-SoR (Civil & Electrical) vide G.O. 1st cited.

In accordance therewith, the Committee has in their concluding meeting dt: 15/07/2021
finalized and approved the Buildings-SoR: 2021-22.

The rates for the Building items (Civil, Water Supply & Sanitary and Electrical items) are to
be followed henceforth by all the concerned departments for building works. The rates for Labour,
Common Material & Work items, Public Health items, Conveyance Rates of Materials & Hire
charges are applicable as per approved and published Common SoR-2021-22 .

The Heads of Departments mentioned below are authorized to print the Buildings-SoR:
2021-22. Unauthorized printing & selling of the Buildings-SoR is strictly prohibited.

The Buildings SoR 2021-22 will come into force along with common SoR from the date
decided by the BoCE.

The receipt of the proceedings may please be acknowledged.

Encloseres: Buildings SoR: 2021-22 as above

Sd/-P.C Ramesh Kumar


Chief Engineer (R&B) Buildings, RSW ,
NABARD, RR,& LWE,
Convener-Member,
Committee of Chief Engineers-Buildings-SoR

To

1) Engineer-In-Chief, Public Health Engineering, Member, Flat No.504 &601, Garuda


Enclave, Tadepalli , Guntur-522501.
2) Engineer-In-Chief,Panchayathraj, Member, Administration, PMGSY,APRRP-
AIIB,VQC,ZP compound, opp PWD Grounds, MG Road, Vijayawada - 520002.
ii
3) Engineer-In-Chief,Tribal Welfare , Member, D.No.40-6-22A, Kandhari Hotel Road,
Adjacent to Southern Spice, Revenue Colony, Vijayawada-520010.
4) Chief Engineer, A.P. Housing Board, Member,D.No. 5-21, Prasadampadu, Elururoad,
Vijayawada -521108
5) Chief Engineer, A.P.Housing Corporation, S.P’s river view apartments, 2nd floor,
Tadepalli , Amaravati-522501..
6) Chief Engineer, APSRTC,RTC House, 1st Floor of PNBS,Vijayawada.
7) Chief Engineer, A.P. Medical Services and Infrastructure Developmen Corporation,
Member, Autonagar, Mangalagiri, 522503. Andhrapradesh
8) Chief Engineer, Police Housing Corporation, AP, Member, Tadepalli, Vijayawada
9) Chief Engineer (R&B) Electrical, Member, M.G.Road, Vijayawada.
10) Chief Engineer, Civil TTD, Member, Administrative Building, KT Road, Tirupathi,
517501 -AP.
11) Chief Engineer, O/o Vijayawada Municipal Corporation, Canal road, Krishnalanka,
Vijayawada ,520001A.P.

Copy to
1. The Engineer-in-Chief (Admn , ), R&B Department, M.G road, Vijayawada.
2. The Chief Engineer (QC), R&B Department, M.G road , Vijayawada .
3. The Chief Engineer (COT), 76-16-4A/1,1st floor, Iron Yard, Opp. to Ramayalam,
Gollapudi, Vijayawada-520012.
4. The Chief Engineer, APRSCL, D.No.5-21, Hostel Road, Prasadampadu, Vijayawada-
521108.
5. The Chief Engineer, APEWIDC, Door No.9-76 ,Sai fortune Heights , Block A,
Vaddeswaram Village, Guntur District - 522 502.

iii
INDEXFORBUILDINGSSoR: 2021-22
(Civil,WaterSupply& Sanitary,ElectricalandElectro-Mechanicalitems)

Sl.
DESCRIPTION PageNo:
No:

From To

BUILDINGS–SoR:2021-22

Letter Dt.19-07-2021 forCommunicationofBuildings SoR 2021- ii iii


22(Civil,WaterSupply&Sanitary, ElectricalandElectro-
Mechanicalitems)
1 IndexforBuildingsSoR2021-22(Civil,Water Supply 1 5
&Sanitary,ElectricalandElectro-Mechanicalitems)

2 Preamble of BuildingsSoR-2021-22(Civil, Water Supply & 6 8


Sanitary,ElectricalandElectro-Mechanicalitems)

3 BuildingCivilItems-Buildings-SoR-2021-22 9 161

4 Note for Buildings CivilItems 162 162

5 List of Recommended Brands / Manufactureres for BuildingCivilItems 163 165

6 WaterSupply&SanitaryItems-Buildings-SoR-2021-22 166 213

7 Note for WaterSupply&SanitaryItems 213 214

8 List of Recommended Brands / Manufactureres for 215 216


WaterSupply&SanitaryItems
9 ElectricalandElectro-MechanicalItems–Buildings-SoR-2021-22 1 300

1
INDEXFORBUILIDNGCIVILITEMS

Sl.No SECTION DESCRIPTIONOFTHEITEM FROM TO

A BRICKS&BUILDINGBLOCKS 10 12
SUB-
I ORDINARYCLAYBRICKS
SECTION
SUB-
II FLY-ASHCEMENT/LIMESOLIDBLOCKS
SECTION
SUB-
III AUTOCLAVEDCONCRETEBLOCKS
SECTION
B NATURALFLOORINGSTONES 12 13
SUB- LOCALLYAVAILABLEFLOORING
I
SECTION STONES
SUB-
II NATURALFLOORINGSTONES- MARBLE
SECTION
SUB-
III NATURALFLOORINGSTONES-GRANITE
SECTION
C WALL&FLOORTILES 13 18
SUB- NON-
I
SECTION PORCELAINCERAMICFLOORTILES
SUB-
II PORCELAINVITRIFIEDFLOORTILES
SECTION
SUB-
III CERAMICWALLTILES
SECTION
SUB-
IV PORCELAINWALLTILES
SECTION
SUB-
V GLASSMOSAICTILES
SECTION
SUB-
VI WALLCLADDINGTILES
SECTION
SUB-
VII EPOXY FLOORING, COVING
SECTION
D. PAVING&INTERLOCKINGTILES 18 21

TERRAZZOFLOORTILES(PLAIN&
SUB-
I. CHEQURED)
SECTION
CEMENTCONRETEFLOORTILES(PLAIN&
SUB-
II. CHEQUERED)
SECTION
PRE-
SUB-
III. CASTCONCRETEBLOCKSFORPAVIN
SECTION
G
SUB-
IV. SECTION VINYLFLOORING
E. TIMBER&ROOFINGMATERIALS 21 23
SUB-
I MEDIUMTEAKWOOD
SECTION
SUB-
II BESTTEAKWOOD
SECTION
SUB-
III BURMATEAKWOOD
SECTION
SUB-
IV ASSAMTEAKWOOD
SECTION

2
SUB-
V SAL/COUNTRYWOOD
SECTION

Sl.No DESCRIPTIONOFTHEITEM FROM TO


SECTION
SUB-
VI ROOFINGMATERIAL
SECTION
23 26
F. STEELMATERIALS

SUB-
I MILDSTEELMATERIALS
SECTION
SUB-
II GALVANIZEDSTEELMATERIALS
SECTION
SUB-
III STAINLESSSTEELMATERIALS
SECTION

G. FIXTURESFOR DOORS& WINDOWS 26 31


SUB-
I TOWERBOLTS
SECTION
SUB-
II HINGES
SECTION
SUB-
III DOORHANDLES
SECTION
SUB-
IV ALDROPS
SECTION
SUB-
V LATCHES
SECTION
SUB-
VI DOORCLOSURES
SECTION
SUB-
VII FLOORSPRINGS
SECTION
SUB-
VIII MORTICELOCKS
SECTION
SUB-
IX OTHERACCESSORIES
SECTION

H. CONSTRUCTIONCHEMICALS&ADMIXTUR 31 55
ES
SUB-
I REPAIRING&TREATMENTWORKS
SECTION
SUB-
II INTERGRALWATERPROOFINGCOMPOUN
SECTION
D
SUB-
III PLASTICIZERSANDWATERREDUCINGAGE
SECTION
NT
SUB-
IV GROUTS
SECTION
SUB-
V BONDINGAGENTS
SECTION
SUB-
VI SEALANTS
SECTION
SUB-
PROTECTIVEWATERPROOFCOATINGS/C
SECTION
VII EMENTBASEDCOATINGS:
SUB-
VIII ANTICORROSIVEAGENTS
SECTION
SUB-
IX. CURING COMPOUND
SECTION
&MISCELLANEOUSCHEMICALS

3
Sl.No SECTION DESCRIPTIONOFTHEITEM FROM TO

I. GLASSMATERIALS 55 56
SUB-
I PLAINGLASSPANES
SECTION
SUB-
II PINHEADED GLASSPANES
SECTION

J. PAINTS&POLISHES 56 59

SUB-
I PRIMERS,FILLERS&BASES
SECTION
SUB-
II DISTEMPERPAINTS
SECTION
SUB-
III EMULSIONBASEDPAINTS
SECTION
SUB-
IV SOLVENTBASEDPAINTS
SECTION
SUB-
V OILBASED ENAMELPAINTS
SECTION
SUB-
VI TEXTUREPAINTS
SECTION
SUB-
VII SPECIALPAINTS
SECTION

K. PARTICLEBOARDS 59 64

SUB-
I MELAMINEFACEDPLAINPARTICLEBOARD
SECTION
SUB-
II INSULATINGPARTICLEBOARDS
SECTION
SUB-
III MEDIUMDENSITYFIBREBOARDS
SECTION
SUB-
IV CEMENTBONDEDPARTICLEBOARDS
SECTION

L. PLYWOODS,LAMINATES&VENEERS 64 66

SUB-
I MOISTURERESISTANT(MR)GRADE
SECTION
SUB-
II BOILINGWATERRESISTANT(BWR)GRADE
SECTION
SUB-
III VENEEREDDECORATIVEPLYWOOD
SECTION
SUB-
IV LAMINATES
SECTION
SUB-
V COMMERCIALVENEERS
SECTION

M. CEILINGS,WALLPARTITIONS&WALLLININ 66 83
GS
SUB-
I FALSECEILINGs-TILES/SHEETS
SECTION
SUB-
II FALSECEILINGs-
SECTION
SECTIONS&ACCESSORIES
SUB-
III WALLLINING&PANELLING
SECTION
SUB-
IV PARTITIONS
SECTION

4
Sl.No SECTION DESCRIPTIONOFTHEITEM FROM TO

N. DOORS,SHUTTERS&FRAMES 83 113

SUB-
I DOORFRAMES
SECTION
SUB-
II DOORSHUTTERSWITHOUTFRAMES
SECTION
SUB-
III DOORSWITHSHUTTERS &FRAMES
SECTION
SUB-
IV CUP-BOARDDOORS
SECTION
P. WINDOWS 113 138
SUB-
I OPENABLEWINDOWS
SECTION
SUB-
II SLIDINGWINDOWS
SECTION
SUB-
III VENTILLATORS
SECTION
STRUCTURALGLAZING&CURTAIN 138 140
Q.
WALLING
SUB-
I FIXEDGLAZING
SECTION
SUB-
II STRUCTURALGLAZING
SECTION
SUB-
III CURTAINWALLING
SECTION
S. SECTION DISMANTLING 140 141
T. SECTION READYMIXCONCRETE 141 141
U. SECTION EXPANSIONJOINTFILLERS 141 142
V. SECTION LABOURCHARGES 142 147
W. SECTION MISCELLANEOUSITEMS 147 155
X. SECTION MACHINERY&OTHERHIRECHARGES 155 156
Y. SECTION POST TENSIONING WORKS 156 157
CENTERINGANDSCAFFOLDING
158 161
CHARGES

5
BUILDINGSSoR: 2021-22
(Civil,WaterSupply&Sanitary,ElectricalandElectro-Mechanicalitems)

PREAMBLE
1.0 INTRODUCTION
The Government have issued orders vide. G.O.Rt.No.95, T, R&B (R.1Buildings)
Dept.,dt:18.01.2015 constituting a Committee comprising of Chief Engineers of
departments in-charge of execution of building works for finalization of Schedule of Rates
forBuildings (Civil, Water Supply & Sanitary and Electrical and Electro-Mechanical items).
Themeeting of the above “SoR Committee of Chief Engineers for Buildings (Civil, Water
Supply & Sanitary,Electrical and Electro-Mechanical items)” was convened several times
during the year2021 and finalized on 16.07.2021 with an objective to finalize and release
the Buildings-SoR: 2021-22.
In formulation of the SoR 2021-22, indices from WPI (Wholesale Price Index) and CIDC
(Construction Industry Development Council) for the year 2020-21 were refered. For
Labour Rates the lobour commissioner of AP recommendations are taken into account.
BoCE labour rates are refered. For different section materials, market quotations are
obtained utilizing the services of member departments.
The rates and proceedures followed in Telangana SoR 2021-22 which is released in June
2021 is also discussed and deliberated.

2.0APPLICABILITYOFCOMMONSoR–2021-22
The rates of labour, common materials & work items, Public Health items,
conveyanceratesofmaterials& hirechargesapprovedandpublishedinCommonSoR-2021-
22remain applicable. The specifications, stipulations & all other conditions of Common-
SoRotherthanthosespecifiedinthis contextremainapplicable.

3.0 OVERHEADS&CONTRACTORSPROFIT
a. The provision of ‘Over Heads and Contractor’s Profit @ 13.615% shall be allowed
inall the data items of the estimates and rates of the finished items in building
workswhere ‘Contractors All Risk’policy isdispensedwith.
b. Itisreiteratedthattheprovisionof‘OverHeadsandContractor’sProfit’isapplicableto
Building works since the advent of the AP. Revised standard data-2009, which
isapproved by the Government in G.O.Ms.No.49 I&CAD (PW-Reforms) Dept.,
dated:02-03-2009andthiscomponentshallbeoperativeonallthedataitemsoftheestimates
and rates of the finished items published in Buildings SoR for all originalworks and
major Renovationworks subjected to the fulfillment of the conditionsgiven below:
i. Siteaccommodation,settingupplant,accessroad,watersupply,electricityand
generalsitearrangements.
ii. Officefurniture,equipmentandcommunications.
iii. Expenditureon:
a) Corporateofficeofcontractor.
b) Technical agents for site supervision. (Reimbursement to the
technicalagents provision is dispensed with where ‘over heads and
contractor’sprofit’provision is included inthe datarates)
c) Documentationand“asbuilt”drawings.
d) Mobilization/de-mobilizationofresources.
e) Labourcampswithminimumamenitiesandtransportationto worksites.
f) Lightvehiclesforsitesupervisionincludingadministrativeandmanagerialre
quirements.
g) Laboratory equipment and quality control including field and
laboratorytesting.(ForalltheworkscostingmorethanRs.2Crorescontr
actors havetoestablish Quality Controllaboratory)
h) Minor T & P and survey instruments and setting outworks,
6
includingverification ofline,dimensions,etc.
i) Watchandward.
j) Trafficmanagement/Safetymanagementduringconstruction.
k) Expenditureonsafeguardingenvironment.
iv. Sundries.
v. FinancingExpenditure.
vi. Sales/ Turn overtax is replaced with GST wef 01.07.2017. The rates arrived
inthis SoR are only basic rates which are exclusive of all taxes. However, as
perthe suggestion of BoCE, the provision towards Works Contract Tax as
perapplicableGST rates shallbeaddedinthe estimates.
vii. Work Insurance/ compensation - Works insurance is dispensed with vide
G.O.Ms.No:61Irrigation&CAD(PW: Reforms)DepartmentDt.25-06-2013.Further,
Itisdecidednottoinsistuponinsuringallthebuildingworksasprovisionforthiscompon
entisalreadydeletedfromthe‘Overheads&Contractor’sProfit’ in buildingworks.

4.0 OTHERGUIDELINES
1. Municipal Area Allowance, Agency or Tribal area allowance or any such allowance
onthe labour components of civil, water supply & sanitary items, Electrical and
Electro-Mechanical items of building works shall be allowed wherever applicable as
per theguidelines and preamble of Common SoR: 2021-22. For the building work
estimatestaken up in the notified Area Development Authorities constituted by the
Government,the Area Allowance on the labour components of civil, water supply &
sanitary items,Electrical and Electro-Mechanical items of building works may be
allowed on specificrecommendationfromsuch AreaDevelopmentAuthorities.
2. For the structures where the Standard and High Strength Concretes vide IS: 456-
2000 is required, mix design shall be carried out and rates may be arrived as per
therateanalysis appendedintheA.P.RevisedStandardData-2009.
3. CertainitemsintheSoRaredeletedduetochangeinthespecification,non-
availabilityinthemarketetc.,
4. The Electrical and Electro-Mechanical items and corresponding rates, as proposed by
the Chief
Engineer(R&B)Electricalinthemeeting,havebeenconsideredintheBuildingsSoR-2021-
22.
5. The specifications of the aggregates for sizes and gradation and its adoption shall
beasper IS383-1970andIS2386(Part1toPart8).
6. No allowance towards ‘Labour Importation & Labour Amenities’ shall be added to
thedataastheyareincludedintheprovisionof‘Overheadsandcontractor’s profit’.
7. For all the materials, the basic rates given in the Buildings SoR are ‘landing prices’
atthesite whichareexclusive ofalltaxes,exceptwherementionedspecifically.
8. Forthematerialswherethebasicratesarementionedas‘quarryrates’intheBuildings SoR
lead charges are to be added
fortheleaddistancesfromtheapprovedquarriesasapplicable.Wherevertheterm“carriage”
or “conveyance” is used in schedule item, it shall be taken to include
actualleads,lifts,loading,unloadingandstackingtothesatisfactionofthetechnicalsanctionin
gauthority whilemakingtheprice-adjustments.
9. The conveyance charges perunit quantity of the materialsare worked out,and provided
in the schedule of rates reckoning
i) for head loads with increment of 50 m upto 150m
ii) for mechanical conveyance with increment of 1 KM.

10. For building works taken up in the hill areas where the materials are conveyed on
ghatroads, the lead distance may be taken as 2.0 times of the existing length of the
road forthe purpose of leads only for conveyance of materials based on the certificate
for theGhatRoadgivenbytheSuperintendingEngineerconcerned.
11. Loadingandunloadingchargesarenotpayableforconveyancebyheadload.
12. Loadingandunloadingchargesarenotpayableforconveyancebymechanicalmeans,
fordisposal ofexcavatedmaterial unless specified.
13. The rates for unloading of materials except earth, sand, gravel, coarse
7
aggregate,rubble,sizestone and cutstone, areinclusiveof stackingwhereverapplicable.
14. The input rate for the water charges taken in Common Standard Schedule of Rates
forthe basic data is for the sources at site, any water lead as applicable may be
allowedasper theconveyancecharges.
15. Unless otherwise specified, all material rates shall be exclusive of all taxes,
duties,levies, royalty/seigniorage.
16. Any errors, omissions, corrections or suggestions shall be brought to the notice of
the‘COMMITTEEOFTHECHIEFENGINEERS(BuildingsSoR)’forcorrectiveaction.
17. For any new items to be included in the ‘Schedule of Rates’, recommendations
withspecific remarks of the respective departments should reach the ‘Committee of
ChiefEngineers’wellinadvance.
18. TheCWC(MinistryofIrrigation)hasrecommendedthat“wherestandardorscheduleof rates
are revised or where is necessary to do so, the primary guiding
principleshouldbeescalationinlabourandmaterialcostandnotontrendofratesquotedbythe
contractors”. The ‘Committee of Chief engineers’ (Buildings SoR) have consideredthe
practicality and adoptability of the ‘Buildings-SoR’ in construction of the
buildingprojectsinfinalizing the ‘Buildings-SoR’.
19. Wherever feasible, more emphasis is given to the technical specifications for the SoR
items by removing the brand names of the manufacturers from the specification.
20. The technical specifications and the rates of the corresponding items given in the
SoRare for the guidance only. The estimate preparing authorities are requested to
obtainliterature for usage / application of construction / water proofing materials,
epoxies etc,from the manufacturers or authorized suppliers in the contract documents
as per therequirement.
21. Steel Centering & Scaffolding charges for Shear walls, RCC walls and Water tank
walls are incorporated in this Buildings SoR 2021-22. The rates given in the SoR are
for both faces of the respective members. The measurement of centering charges
shall be in ‘sqm’ for one face only and the centering charges given are for two faces of
centering.
22. Double Grooved and Precoated extruded Mineral (Cement) roof tiles are introduced.
23. Clarity on nomenclature of Floors for data calculations is given as below
For To Read
GF F1
FF F2
SF F3
TF F4
24. A separate section for Post Tensioning works is introduced.

5.0 CONCLUSION
1. The Committee of Chief Engineers on Buildings-SoR: 2021-22 (Civil & Electrical) has
metin the chambers of Chief Engineer (R&B) Buildings& RSW, several times during
theyear 2021and approved the Buildings SoR:2021-22,without any tax elements based
ontherepresentationsreceivedfromvariousEngineeringDepartments.Asperthesuggestion of
BoCE, 12% GST rate on the Estimate Contract Value(ECV) towards
workscontractshallbeprovidedinPart-Bof theestimate duringpreparationofestimates.

2. SSR Rates for Civil, Sanitary & water supply and Electrical Items are purely for
theguidance of the officers in preparation of estimates vide Para 113 of APPWD
code.Authoritywhopreparestheestimateishoweverresponsibleforproperratesasenvisag
edinPara45ofAPPWDcode.
3. The rates published in the Buildings SoR are ceiling rates and the estimate
preparingauthorities are responsible for the correctness and reasonableness of the
TechnicalSpecificationsandRatesadoptedintheestimates.

8
BUILDINGITEMS

9
BasicRat
e
S.No CFMScode ItemCode Descriptionofitem Unit forSoR20
21-
22(Rs.)
1 2 3 4 5
BRICKS&BUILDINGBLOCKS
A.SECTION (ex-quarryprice-
excludingcostofconveyance,loading&unl
oading)
I. SUB- ORDINARYCLAYBRICKS
SECTION
Common burnt clay bricks of class
1 MAT-00721 BMT-A.01 asperTable-1ofIS:1077-1992Non- 1000 6400
Modularoftraditionalsize23x11x7cm Nos

Common burnt clay bricks of class asper


2 MAT-00748 BMT-A.02 1000 7200
Table-1 of IS:1077-1992 Modular
Nos
oftraditionalsize19x 9x9cm
FLY-ASHCEMENT/LIMESOLIDBLOCKS
II. SUB- (ex-quarryprice-
SECTION excludingcostofconveyance,loading&unl
oading)
Flyashcement/limesolidblockswithcompressi
3 MAT-00749 BMT-A.03 ve strength of 75 kg/sq.cm -IS:12894-1990- Each 28
CLASS-7.5-290x
225x140 mm
Flyashcement/limesolidblockswithcompressi
4 MAT-00750 BMT-A.04 ve strength of 75 kg/sq.cm -IS:12894-1990- Each 25
CLASS-7.5-290x
200x140 mm
Flyashcement/limesolidblockswithcompressi
5 MAT-00751 BMT-A.05 ve strength of 75 kg/sq.cm -IS:12894-1990- Each 21
CLASS-7.5-290x
150x140 mm
Flyashcement/limesolidblockswithcompressi
6 MAT-00752 BMT-A.06 ve strength of 75 kg/sq.cm -IS:12894-1990- Each 16
CLASS-7.5-290x
112/100x 140mm
Flyashcement/limesolidblockswithcompressi
7 MAT-00753 BMT-A.07 ve strength of 75 kg/sq.cm -IS:12894-1990- Each 8.5
CLASS-7.5-225x
100x60mm
Flyashcement/limesolidblockswithcompressi
8 MAT-00754 BMT-A.08 ve strength of 75 kg/sq.cm -IS:12894-1990- Each 17
CLASS-7.5-145x
225x140 mm
Flyashcement/limesolidblockswithcompressi
9 MAT-00755 BMT-A.09 ve strength of 75 kg/sq.cm -IS:12894-1990- Each 12.5
CLASS-7.5-145x
200x140 mm
Fly ash cement/ lime solid blocks
10 MAT-00756 BMT-A.10 withcompressive strength of50 kg/sq.cm - Each 25
IS:12894-1990- CLASS -5 -290x 225 x
140mm

10
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Fly ash cement/ lime solid blocks
11 MAT-00757 BMT-A.11 withcompressive strength of50 kg/sq.cm Each 21
-IS:12894-1990- CLASS -5 -290x 200 x
140mm
Fly ash cement/ lime solid blocks
withcompressive strength of50 kg/sq.cm
-IS:12894-1990-CLASS-5-Flyash
12 MAT-00758 BMT-A.12 cement/limesolidblockswithcompressive Each 22
strength of50 kg/sq.cm -IS:12894-1990-
CLASS -5-290 x 150x
140mm
Fly ash cement/ lime solid blocks
13 MAT-00759 BMT-A.13 withcompressive strength of50 kg/sq.cm Each 11.5
-IS:12894-1990-CLASS-5-290x
112/100x 140mm
Fly ash cement/ lime solid blocks
14 MAT-00760 BMT-A.14 withcompressive strength of50 kg/sq.cm Each 6.5
-IS:12894-1990- CLASS -5 -225x 100 x
60mm
Fly ash cement/ lime solid blocks
15 MAT-00761 BMT-A.15 withcompressive strength of50 kg/sq.cm Each 12.5
-IS:12894-1990- CLASS -5 -145x 225 x
140mm
Fly ash cement/ lime solid blocks
16 MAT-00762 BMT-A.16 withcompressive strength of50 kg/sq.cm Each 11.5
-IS:12894-1990- CLASS -5 -145x 200 x
140mm
Supplyofwellburntcinderaggregatesaspe 1
17 MAT-00763 BMT-A.17 650
rIS:2686-1977 Cum
AUTOCLAVEDCONCRETEBLOCKS
III. SUB-
(landing cost - including cost
SECTION
ofconveyance,loading&unloading
)
SupplyofAerated(Cellular)Autoclaved
ConcreteBlocksconforming to
IS:2185 (Part-3) - 1984andIS:6441-
2
1972ofCompressivestrength3N/mm

18 MAT-00764 BMT-A.18 600x200x100 mm Each 48


19 MAT-00765 BMT-A.19 600x200x150 mm Each 70
20 MAT-00766 BMT-A.20 600x200x200 mm Each 94
21 MAT-00767 BMT-A.21 600x200x230 mm Each 107
Supply of Cement based,
22(a) MAT-05337 BMT-A.22 PolymermodifiedPre- 1Kg 15
mixeddryjointingmortarfor laying AAC
Blocks – Masonry Glue110
orequivalent
22(b) MAT-08727 BMT-A.23 SupplyofCementbased,Polymer 1Kg 13

11
Basic
Rate for
S. No CFMS code Item Code Description of item Unit SoR
2021-
22 (Rs.)
1 2 3 4 5
modifiedPre-mixed bonding
coatforplasteringonsmoothconcrete/ma
sonrysurfaces.
Supply of Cement based,
22(c) BMT-A.24 PolymermodifiedPre-mixed dry 1Kg 10
MAT-08728
plasteringmortarforplasteringwalls,c
olumns,ceilings.
Supply of Cement based,
22(d) MAT-08729 BMT-A.25 PolymermodifiedPre-mixed 1Kg 15
drymortarforfixingtilesonwalls &floors
NATURALFLOORINGSTONES
B.SECTION (ex-quarryprice–
excludingcostofconveyance,loading&
unloading)
I.SUB- LOCALLYAVAILABLEFLOORING
SECTION STONES
Kadapaslab40mmthickandsizenotlesstha 1
23 MAT-00768 BMT-B.01 120
n0.457Mx0.457M Sqm
Kadapaslab50mmthickandsizenotlesstha 1
24 MAT-00769 BMT-B.02 140
n0.457Mx0.457M Sqm
Shahabad/TandurRoughStoneslabsofmi 10
25 MAT-00770 BMT-B.03 1000
nimumof25 mmthick Sqm
Shahabad/TandurRoughStoneslabsofmi 10
26 MAT-00771 BMT-B.04 1300
nimum40mm thick Sqm
PolishedShahabad/Tandurstoneslabsof1 10
27 MAT-00772 BMT-B.05 1650
5to 18mmthick Sqm
PolishedblackKadapaslabsminimumof15 10
28 MAT-00773 BMT-B.06 1500
mm thick (0.457x0.457M) Sqm
PolishedBethamcherlapure(marbletype)
29 MAT-00774 BMT-B.07 10 4000
white stone minimum 25 mm
Sqm
thick(0.254Mx0.254M)
PolishedBethamcherlacolouredstonemin
30 MAT-00775 BMT-B.08 10 2800
imum25mmthick(0.254Mx0.254M)
Sqm

Polished 10
31 MAT-00784 BMT-B.17 1600
blackKadapaslabsofallsize Sqm
sbetween 25 -30mmthickness
II.SUB- NATURALFLOORINGSTONES-
SECTION MARBLE
PolishedMarbleslabsofDongari/Adanga/
32 MAT-00779 BMT-B.12 Marodh/Rajgangpuretc.,varietyof 1sqm 680
thickness between 16 mm
to20mmofsizesfrom 600mmto900 mm
PolishedMarbleslabsofDongari/Adanga/
33 MAT-00780 BMT-B.13 Marodh/Rajgangpuretc.,varietyof 1sqm 550
thickness between 16 mm
to20mmofsizesupto600 mm
34 MAT-00781 BMT-B.14 PolishedMarbleslabs ofany variety and 1sqm 930

12
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
gangsawcut(SuchasDongari/Adanga/Marodh/
Rajgangpuretc)16mm to 20 mm (average)
thick ( 0.610 Mwidthofany length)

PolishedMarbleTilesof8-10mmthicknessof
35 MAT-00782 BMT-B.15 1sqm 440
allsizesandvarieties
III.SUB- NATURALFLOORINGSTONES-
SECTION GRANITE
High Polished Granite 16 to 18 mm thickup to
36 MAT-00776 BMT-B.09 1 2695
2.43 M other than black/ premiumcolours
Sqm

High Polished Granite 16 to 18 mmthick up to


37 MAT-00777 BMT-B.10 1 2342
2.43 M other than black andregularcolours
Sqm

HighPolishedGranite 1
38 MAT-00778 BMT-B.11 1991
16to18mmthickupto Sqm
2.43Mblack
Granitestonetiles8mmthick(mirrorpolished
39 MAT-00783 BMT-B.16 1sqm 1005
ofallshades)
WALL&FLOORTILES
C.SECTION (Landingcost–includingloading,costof
conveyance,unloading)
I.SUB- NON-PORCELAINCERAMICFLOORTILES
SECTION
Supply of Non-skid red or white full
bodyCeramic floor tiles of Size 300 mm x
300mm and thickness between 7-8 mm 1
40 MAT-00785 BMT-C.01 and1stqualityconformingtoIS:13711,IS:13712,I Sqm 370
S:13630 (Parts1to15)of
any colour and finish in all shades anddesigns

Supply of Non-skid red or white full


bodyCeramic floor tiles of Size 450 mm x
450mm and thickness between 7-8 mm 1
41 MAT-00786 BMT-C.02 and1stqualityconformingtoIS:13711,IS:13712,I Sqm 374
S:13630 (Parts1to15)of
any colour and finish in all shades anddesigns

Supply of Non-skid red or white full


bodyCeramic floor tiles of Size 600 mm x
600mmandthicknessbetween8-10mmand 1st 1
42 MAT-00787 BMT-C.03 quality conforming to Sqm 484
IS:13711,IS:13712,IS:13630 (Parts1to15)of
any colour and finish in all shades anddesigns

SupplyofNon-skidredorwhitefullbodyCeramic
floor tiles of Scratch free-stainfree and scratch 1 508
43 MAT-00788 BMT-C.04 free-nano finish of Size600 mmx 600 mmand Sqm
thickness

13
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
between 8-10 mm and 1st
qualityconforming to IS:13711,
IS:13712,IS:13630 (Parts 1 to 15) of any
colourandfinishinallshadesanddesigns

II. SUB-
SECTION PORCELAINVITRIFIEDFLOORTILES

44 MAT-00789 BMT-C.05 ITEMDELETED


Supply of soluble salt porcelain vitrifiedtiles
screen printed and polished of size600 x600
mmand thicknessbetween 8- 1
45 MAT-00790 BMT-C.06 10mm1stqualityconformingtoIS:13711, Sqm 418
IS:13712, IS:13630
(Parts1to15)ofanycolourandfinishinallshades
anddesigns.
SupplyofNanopolished/stainfreesolublesaltp
orcelainvitrifiedtilesscreen printedofsize600
x 600mmandthicknessbetween8-
46 MAT-00791 BMT-C.07 10mm1stqualityconformingtoIS:13711,IS:13 1 421
712,IS:13630 (Parts1to15)of Sqm
any colour and finish in all shades
anddesigns

47 MAT-00792 BMT-C.08 ITEMDELETED


Supply of Double charged / multicharged
stain free full body
porcelainvitrifiedtileswithdouble
layerpigmentof 1st quality conforming to
IS:13711,IS:13712,IS:13630(Parts1to
15)of
anycolourandfinishinallshadesanddesigns
Supply of Double charged / multicharged
stain free full body
porcelainvitrifiedtileswithdouble
48 MAT-00793 BMT-C.09 layerpigmentof Size 600 x 600 mm and 1 612
thicknessbetween 8-10 mmand 1st Sqm
qualityconforming to IS:13711,
IS:13712,IS:13630 (Parts 1 to 15) of any
colourandfinishinallshadesand designs
Supply of Double charged / multicharged
stain free full body
porcelainvitrifiedtileswithdouble
49 MAT-00794 BMT-C.10 layerpigmentof Size 800 x 800 mm and 1 758
thicknessbetween 9-11 mmand 1st Sqm
qualityconforming to IS:13711,
IS:13712,IS:13630 (Parts 1 to 15) of any
colourandfinishinallshadesand designs
50 MAT-00795 BMT-C.11 ITEMDELETED
51 MAT-00796 BMT-C.12 Supplyofdigital/polishedglazedfull 1 718

14
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
bodyporcelainvitrifiedtileswithanytype of Sqm
design texture such as marblefinish,
wooden, bamboo, stone
finishesetc.,scratchless,stainfreeandSiz
e800 x800 mmand thicknessbetween 9-
11mmof1stqualityconformingtoIS:13711,
IS:13712,IS:13630(Parts1to15)ofanycol
ourandfinishinallshadesanddesigns

Supply of digital /polished


glazedfullbodyporcelainvitrifiedtileswitha
nytype of design texture such as
marblefinish, wooden, bamboo, stone
52 MAT-00797 BMT-C.13 1 924
finishesetc.,scratchless,stainfreeandSiz
Sqm
e900 x900 mmand thicknessbetween 9-
11mmof1stqualityconformingtoIS:13711,
IS:13712, IS:13630
(Parts1to15)ofanycolourandfinishinallsh
adesanddesigns
Supply of glazed vitrified tiles with
mattfinishofsize600x600mmandthicknes
52(a) BMT- sbetween 9-10 mm 1st quality 1 818
C.13(a) confirmingtoIS:13711,IS:13712,IS:1363 Sqm
MAT-08730
0(Parts
1to
15)ofanycolurandfinishinallshadesandde
signs .
53to BMT-
59 C.14toBMT- ITEMSDELETED
C.20
III.SUB-
SECTION CERAMICWALLTILES

Supply of glazed red or white full


bodyceramicwalltilesofSize200x300mm
/ 245 mm x 325 mm and 1
60 MAT-00805 BMT-C.21 thickness6mmand1stqualityconformingt Sqm 323
oIS:13711,IS:13712,IS:13630(Parts1
to15)ofanycolourandfinishinallshadesan
ddesigns
Supply of glazed red or white full
bodyceramicwalltilesofSize300x450mm
/ 320 mm x 400 mm and 1
61 MAT-00806 BMT-C.22 thickness6mmand1stqualityconformingt Sqm 396
oIS:13711,IS:13712,IS:13630(Parts1
to15)ofanycolourandfinishinallshadesan
ddesigns
Supply of glazed red or white full
bodyceramic wall tiles of Size 300 x 600
mmand thickness between 6-8 mm and 1 538
62 MAT-00807 BMT-C.23 1stqualityconformingtoIS:13711,IS:1371 Sqm
2,IS:13630 (Parts1to15)of
any colour and finish in all shades
anddesigns

15
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
IV.SUB- PORCELAINWALLTILES
SECTION
Supplyofglazedfullbodyporcelainwall
tiles of size 300 x 600 mm with anytype
of design texture such as marblefinish,
wooden, bamboo, stone 1
63 MAT-00808 BMT-C.24 Sqm 554
finishesetc.,scratchless,stainfreeandthic
kness between 6-8 mm 1st
qualityconformingtoIS:13711,IS:13712,I
S:13630 (Parts 1 to 15) of any
colourandfinishinallshades and designs
Supply of digital / polished glazed
fullbody porcelainwall tiles of size 300
x600 mm with any type of design
texturesuch as marble finish, wooden,
64 MAT-00809 BMT-C.25 1 556
bamboo,stonefinishesetc.,scratchless,st
Sqm
ainfree and thickness between 6-8 mm
1stqualityconformingtoIS:13711,IS:1371
2,IS:13630 (Parts1to15)of
any colour and finish in all shades
anddesigns
Supply of digital / polishedglazed
fullbody porcelainhighlighter wall tiles
ofsize300x600mmwithanytypeofdesignt
exturesuchasmarblefinish,wooden,bamb
65 MAT-00810 BMT-C.26 1 564
oo,stonefinishesetc.,scratchless,stainfre
Sqm
eandthicknessbetween 6-8 mm 1st
quality
conformingtoIS:13711,IS:13712,IS:1363
0(Parts
1 to 15) of any colour and finish in
allshadesanddesigns
Supplyofscreenprintedglazedfullbody
porcelainwall tiles of size 300 x600 mm
with any type of design texturesuch as
marble finish, wooden,
66 MAT-00811 BMT-C.27 1 612
bamboo,stonefinishesetc.,scratchless,st
Sqm
ainfree and thickness between 6-8 mm
1stqualityconformingtoIS:13711,IS:1371
2,IS:13630 (Parts1to15)of
any colour and finish in all shades
anddesigns
Supplyofglazedfullbodyporcelainwall
tiles of size 400 x 600 mm with anytype
of design texture such as marblefinish,
wooden, bamboo, stone 1
67 MAT-00812 BMT-C.28 Sqm 726
finishesetc.,scratchless,stainfreeandthic
kness between 6-8mm 1st
qualityconformingtoIS:13711,IS:13712,I
S:13630 (Parts 1 to 15) of any
colourandfinishinallshades and designs
68to BMT-C.29 ITEMSDELETED
70 toBMT-
C.31

16
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Providingandfixingwalldadowithepoxyem
ulsiongrout/synthetic/resinbasedadhesiv 1
71 MAT-00816 BMT-C.32 einspecifiedthickandpointingwithspecifie Sqm 294
dcolourepoxygroutexcludingcostoftiles

Providingandfixingwalldadowithcementb
72 MAT-00817 BMT-C.33 asedadhesiveinspecifiedthick and 1 149
pointing with specified colourepoxygrout Sqm
excludingcost oftiles
Providingandfixingflooringwithfulldepthjo
intingandpointingtotheVitrified/CeramicTi
leflooringinspecified thickfor tiles of any 1
73 MAT-00818 BMT-C.34 sizes withepoxy emulsion grout/ Sqm 295
synthetic / resinadhesive in width of 3-5
mm with Nylonspacers excludingcost
oftiles.
Providingandfixingflooringwithfulldepthjo
intingandpointingtotheVitrified/CeramicTi
leflooringinspecified thickfor tiles of any 1
74 MAT-00819 BMT-C.35 sizes withcement based adhesive in Sqm 157
width of 3-5mmwith
Nylonspacersexcluding costoftiles .

Providingandfixingflooringwithfulldepthjoi
ntingandpointingtotheMarble/ Granite
75 MAT-00820 BMT-C.36 flooringfor any 1 591
sizeswithepoxyemulsiongrout/synthetic/r Sqm
esin based adhesive in width of 3-5
mmexcludingcostoftiles.
Providingandfixingflooringwithfulldepthjo
intingandpointingtotheMarble/ Granite 1
76 MAT-00821 BMT-C.37 flooringfor any sizeswith cement based Sqm 298
adhesive in width of3-5mm
excludingcostoftiles.
V.SUB-
SECTION GLASSMOSAICTILES

77to BMT-C.38
79 toBMT- ITEMSDELETED
C.40
VI.SUB-
SECTION WALLCLADDINGTILES

Supply of glazed full body porcelain


tilesforexternalcladdingpurposesofanysi
zeand thickness between 6-10 1
80 MAT-00825 BMT-C.41 mm1stqualityconformingtoIS:13711,IS:1 Sqm 527
3712,IS:13630(Parts1to15)of
any colour and finish in all shades
anddesigns.
Supplyofglazedredorwhitefullbodycerami 1
81 MAT-00826 BMT-C.42 422
c tiles for external cladding Sqm

17
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
purposesofanysizeandthicknessbetwe
en 5-7 mm 1st quality
conformingtoIS:13711,IS:13712,IS:1363
0(Parts
1 to 15) of any colour and finish in
allshadesanddesigns
Supply of glazed red or white full
bodyceramictilesforexternalcladdingpurp
osesofanysizeandthicknessbetween10 1
82 MAT-00827 BMT-C.43 - Sqm 437
12mm1stqualityconformingtoIS:13711,I
S:13712,IS:13630 (Parts 1 to 15) of any
colourandfinishinallshades and designs
83 MAT-00828 BMT-C.44 ITEMDELETED
84 Brick tiles of size 230mm x 75 mm and 1
MAT-08731 BMT-C.45 Sqm 400
12mm thick
85 Natural stone (Bethamcherla or 1
MAT-08732 BMT-C.46 equivalent) of size not exceeding Sqm 510
300mm x300mm and 18-20mm thick
86 Terracotta tiles size 125mm x 200mm 1
MAT-08733 BMT-C.47 Sqm 370
and 12-15mm thick
VII SUB-
EPOXY FLOORING, COVING
SECTION
Supply and application of epoxy flooring
of light green or light blue colour
seamless joint free finish with 3mm 1
87 MAT-08734 BMT-C.48 thickness and anti slip & water washable Sqm
chemical resistance durable and non 1710
particle shedding with attractive
finishing
Supply and application of epoxy coving
88 MAT-08735 BMT-C.49 50mmx50mm width at the corners of the 1 RM 470
walls
D.SECTION PAVING&INTERLOCKINGTILES
TERRAZOFLOORTILES(PLAIN&CHEQ
I.SUB- URED)
SECTION (landing cost - including cost
ofconveyance,loading&unloading
)
Supplyingprecastterrazzochequeredtiles
conformingtoIS:13801usingmarbleaggre
gatesofsize10mm,sand,marblepowder,w
89 MAT-00829 BMT-D.01 hitecementpigments etc., with terrazzo 1sqm 266
topping notless than 6 mm of tiles
overall size notless than 20 mm thick of
any colouredshades.

Supplyingprecastterrazzotilesconformin
gtoIS:13801usingmarbleaggregatesofsiz
e10mm,sand,marble powder, white
90 MAT-00830 BMT-D.02 cement pigmentsetc., with terrazzo 1sqm 257
toppingnotless than6 mm of tiles overall
size not less than20mmthick
whiteshades.
18
BasicRat
S.No CFMScode ItemCode Unit e forSoR
Descriptionofitem
2021-
22 (Rs.)
1 2 3 4 5

Supplyingprecastterrazzoplaintilesconfor
ming to IS: 13801using
marbleaggregatesofsize10mm,sand,mar
91 MAT-00831 BMT-D.03 1sqm 272
ble powder, white cement pigmentsetc.,
with terrazzo toppingnotless than6 mm
of tiles overall size not less
than20mmthickanycolouredshades.
II.SUB- CEMENTCONRETEFLOORTILES(
SECTION PLAIN&CHEQUERED)
SupplyingplainCementConcretegeneral
purpose tiles conforming to 1
92 MAT-00832 BMT-D.04 IS:13801usingaggregates,cement,pigme Sqm 241
ntsofsize300x300mmandthickness20
mmofany shades.
Supplying Chequered Cement Concrete 1
MAT-00833 BMT-D.05 252
heavy duty tiles conforming to IS: Sqm
93 13801 using aggregates, cement,
pigments of size 300 x 300 mm and
thickness 20 mm of any shades.
SupplyingplainCementConcretegeneral
purpose tiles conforming to 1
94 MAT-00834 BMT-D.06 IS:13801usingaggregates,cement,pigme Sqm 257
ntsofsize300x300mmandthickness25
mmofany shades.
Supplying Chequered Cement
ConcreteheavydutytilesconformingtoIS:1 1
95 MAT-00835 BMT-D.07 3801usingaggregates,cement,pigments Sqm 269
ofsize300x300mmandthickness25
mmofany shades.
SupplyingplainCementConcretegeneral
purpose tiles conforming to 1
96 MAT-00836 BMT-D.08 IS:13801usingaggregates,cement,pigme Sqm 280
ntsofsize400x400mmandthickness25
mmofany shades.
Supplying Chequered Cement
ConcreteheavydutytilesconformingtoIS:1 1
97 MAT-00837 BMT-D.09 3801usingaggregates,cement,pigments Sqm 288
ofsize400x400mmandthickness25
mmofany shades.
SupplyofhighstrengthCementConcrete
plain Step tiles with edge halfrounded
MAT-00838 BMT-D.10 and grooved conforming 1 419
98 Sqm
toIS:13801usingaggregates,cement,pig
mentsofregularcolour,designandof25mm
thickness
SupplyofhighstrengthCementConcrete
terrazzo/pre-
polished/chequered Step tiles with edge 1
99 MAT-00839 BMT-D.11 roundedand grooved conforming toIS: Sqm 440
13801using aggregates, cement,
pigments ofany premium colour, design
and of 25mmthickness

19
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
III.SUB- PRE-
SECTION CASTCONCRETEBLO
CKSFORPAVING
Supplyofprecastconcreteblocksforpaving
of M-30 grade and thickness notless
MAT-00840 BMT-D.12 than 50 mm for Non-traffic 1 280
100 Sqm
areasconformingtoIS15658:2006inallsha
pesanddesignsasperthemanufacturer's
specification
Supplyofprecastconcreteblocksforpaving
of M-35 grade and thickness notless
MAT-00841 BMT-D.13 than 60 mm for Light traffic 1 320
101 Sqm
areasconformingtoIS15658:2006inallsha
pesanddesignsasperthemanufacturer's
specification
Supplyofprecastconcreteblocksforpaving
of M-40 grade and thickness
MAT-00842 BMT-D.14 notlessthan80mmforMediumtrafficareas 1 450
conforming to IS 15658:2006 in Sqm
102
allshapesanddesignsasperthemanufactu
rer's specification
Supplyofprecastconcreteblocksforpaving
of M-50 grade and thickness notless
MAT-00843 BMT-D.15 than 100 mm for Heavy traffic 1 500
areasconformingtoIS15658:2006inallsha Sqm
103
pesanddesignsasperthemanufacturer's
specification
Supplyofprecastconcreteblocksforpaving
of M-55 grade and thickness notless
MAT-00844 BMT-D.16 than 120 mm for very heavy trafficareas 1 570
conforming to IS 15658:2006 in Sqm
104
allshapesanddesignsasperthemanufactu
rer's specification
Labour charges for laying & fixing
ofprecast concrete blocks for paving of
allgrades, any thickness, all sizes 1
LAB-01180 BMT-D.17 &shapes including all labour charges Sqm 190
105
forloading & unloading, laying to
desiredlinesandlevelscompleteexcludin
gcostofcement,sand,water, electricityetc
Supplyof Glass Fibre Reinforced
Concrete Tiles of size 300 x 300 mm
/400 x 400 mm and thickness of not 1
MAT-08736 BMT-D.21 less than 25mm heavy duty conforming Sqm 355
106
to IS 13801 in
allshapesanddesignsasperthemanufact
urer's specification
Supplyof Glass Fibre Reinforced
Concrete Pavers of size 225 x 175 mm
and thickness of not less than 60mm 1
107 MAT-08737 BMT-D.22 heavy duty conforming to IS Sqm 481
15658:2006 in
allshapesanddesignsasperthemanufact
urer's specification
20
BasicRat
S.No CFMScode Unit e forSoR
ItemCode Descriptionofitem
2021-
22 (Rs.)

1 2 3 4 5

IV.SUB-
SECTION VINYLFLOORING

VinylFlooringSheets/tileshavinganomin
al total thickness of 2 mm with
awearingsurfaceimpregnatedpolyuretha 1
MAT-05338 BMT-D.18 nehomogeneousmixtureofPVC,Plasticiz Sqm 720
108
ers,Urethane,colorpigmentswithwearingr
esistanceandFireResistanceasperstand
ards

VinylCompositionFloorTilesofsize
305mmx
305mmhavinganoverallthicknessof2.0m
MAT-05339 BMT-D.19 mwithawearingsurfaceimpregnatedpolyu 1 452
109 rethanehomogeneousmixtureofPVC,Pla Sqm
sticizers,Urethane,colorpigmentswithwe
aringresistanceandFireResistance as
perstandards

Vinyl Flooring Sheets or tiles having


anominal total thickness of 1.5 mm with
awearingsurfaceimpregnatedpolyuretha 1
MAT-05340 BMT-D.20 nehomogeneousmixtureofPVC,Plasticiz Sqm 327
110
ers,Urethane,colorpigmentswithwearingr
esistanceandFireResistanceasperstand
ards

TIMBER&ROOFINGMATERIALS
E.SECTION
(Landingcost–includingcostof

conveyance,loading&unloading)

Note:BeforeproposingtheTeakWoodIte
ms, the estimating authorities
shallobtain prior approval from
thecompetent authority

I.SUB- MEDIUMTEAKWOOD
SECTION

MediumTeakWoodscantlings:upto
111 MAT-00846 BMT-E.01 1cum 74500
2.0M

MediumTeakWoodscantlings:2.0to
112 MAT-00847 BMT-E.02 1cum 83000
3.0M

21
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
MediumTeakWoodscantlings:above
MAT-00848 BMT-E.03 1cum 91300
113 3.0M

Medium Teak Wood Plancks:


MAT-00849 BMT-E.04 1cum 149000
anythickness
114

II.SUB- BESTTEAKWOOD
SECTION
MAT-00850 BMT-E.05 BestTeakWoodscantlings:upto2.0M 1cum 128000
115

MAT-00851 BMT-E.06 BestTeakWoodscantlings:2.0to3.0M 1cum 137000


116

BestTeakWoodscantlings:above3.0M
117 MAT-00852 BMT-E.07 1cum 145000

MAT-00853 BMT-E.08 BestTeakWood Plancks:anythickness 1cum 161000


118

III.SUB- BURMATEAK WOOD


SECTION
BurmaTeakWoodscantlings:upto2.0M
119 MAT-00854 BMT-E.09 1cum 168485

BurmaTeakWoodscantlings:2.0to3.0M
120 MAT-00855 BMT-E.10 1cum 173298

BurmaTeakWoodscantlings:above
121 MAT-00856 BMT-E.11 1cum 182272
3.0M
Burma Teak Wood Plancks:
122 MAT-00857 BMT-E.12 1cum 197369
anythickness
IV.SUB- ASSAMTEAK WOOD
SECTION
AssamTeakWoodscantlings:anylength
123 MAT-00858 BMT-E.13 1cum 47000

Assam Teak Wood Plancks:


124 MAT-00859 BMT-E.14 1cum 68000
anythickness
V.SUB- SAL/COUNTRYWOOD
SECTION
MAT-00860 BMT-E.15 SalWoodscantlings:anylength 1cum 48500
125

MAT-00861 BMT-E.16 SalWoodPlancks:anythickness 1cum 61000


126

VI.SUB- ROOFINGMATERIAL
SECTION
MAT-00862 BMT-E.17 A.CsheetCorrugated 6mmthick 1sqm 214
127

22
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
128 MAT-00863 BMT-E.18 A.Csheetplain 4mmthick 1sqm 153

129 MAT-00864 BMT-E.19 A.Csheetplain 6mmthick 1sqm 160

PlainorCorrugatedGalvanizedironsheets
130 MAT-00865 BMT-E.20 as per IS 277 (0.1 mm to 0.8 1kg 68
mmthickness)
SupplyofUVresistantmulti-
131 MAT-00866 BMT-E.21 1 1200
wallpolycarbonate sheets for roofing of
Sqm
anycolour - 6mmthick
Aluminium universal glazing set 40
132 MAT-00867 BMT-E.22 mmwideforjointingandfixingpolycarbonat 1RM 114
esheets
Supplyof UV resistant multi -
133 MAT-05341 BMT-E.23 1 1350
wallpolycarbonatesheetsforroofingofan
Sqm
ycolour -10mmthick.

STEELMATERIALS (Landing cost –


F.SECTION including loading, cost of
conveyance,unloading)

I.SUB- MILDSTEEL MATERIALS


SECTION
Supply & fixing of Rolling shutter
madeof 80 x 1.25 mm machine rolled
CRCAlaths, interlocked together through
theirentire length and jointed together at
theendsbyend-
locks,mountedonspecially designed pipe
shaft of 50mmdia nominal bore MS B
134 MAT-00895 BMT-F.29 1 3500
class pipe
Sqm
withbrackets,plates,guidechannels,stopp
ers,bottomlockingplatesandarrangement
sforinside&outsidelockingwithpush-
pulloperationsincluding cost of hood
cover and
springscomplete,paintedwithonecoatofa
pprovedsteelprimer,locks,ballbearings,
allaccessoriesetc completefor finished
item of work as per specialspn:1108
Supplying&fixingcollapsiblesteelshutters
withvertical,doublechannelof
20 x10x2 mm of 100 mm centre
,Bracers with flat iron 40x40x6 mm
135 MAT-00896 BMT-F.30 1 3050
with38 mm dia steel pulleys, the top,
Sqm
bottomandsideverticalframesofthecollap
siblegatewith65x65mmx8mmMS Angle
and middle guide rail at siteheight with
65mmx8mm MS flat for thepulleys to
guide and fixed with

23
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
necessary hold fasts, bolts, nuts,
rivets,lockingarrangements,stoppers,han
dles, all accessories all fixtures
andpainted with one coat of approved
steelprimer etc., complete for finished
item ofworkas per specialspn1105
Expanded metal sheets as per IS-412-
136 MAT-00875 BMT-F.09 1962-LightWeight-25mm(SWM)x75mm 1 140
(LWM)3.25 mm Wide and 1.25 mmthick Sqm

Expanded metal sheets as per IS-412-


137 MAT-00876 BMT-F.10 1962-LightWeight- 1 140
20mm(SWM)x60mm(LWM) 2.50 mm Sqm
Wide and 1.25 mmthick
Expanded metal sheets as per IS-412-
138 MAT-00877 BMT-F.11 1962-LightWeight- 1 140
20mm(SWM)x50mm(LWM) 2.50 mm Sqm
Wide and 1.25 mmthick
Expanded metal sheets as per IS-412-
139 MAT-00878 BMT-F.12 1962- Medium Weight-25 1 195
mm(SWM)x75mm(LWM) 3.25 mm Wide Sqm
and 1.60 mmthick
Expanded metal sheets as per IS-412-
140 MAT-00879 BMT-F.13 1962- Medium Weight-20 1 195
mm(SWM)x60mm(LWM) 2.50 mm Wide Sqm
and 1.60 mmthick
Expanded metal sheets as per IS-412-
141 MAT-00880 BMT-F.14 1962- Medium Weight-20 1 195
mm(SWM)x50mm(LWM) 2.50 mm Wide Sqm
and 1.60 mmthick
Expanded metal sheets as per IS-412-
142 MAT-00881 BMT-F.15 1962- Heavy Weight-25 1 220
mm(SWM)x75mm(LWM) 3.25 mm Wide Sqm
and 2.24 mmthick
Expanded metal sheets as per IS-412- 220
143 MAT-00882 BMT-F.16 1962- Heavy Weight-20 1
mm(SWM)x60mm(LWM) 2.50 mm Wide Sqm
and 2.24 mmthick
Expanded metal sheets as per IS-412-
144 MAT-00883 BMT-F.17 1962- Heavy Weight-20 1 220
mm(SWM)x50mm(LWM) 2.50 mm Wide Sqm
and 2.24 mmthick
145 Rabbitwiremesh(chickenmesh)ofnotlesst 1
MAT-00894 BMT-F.28 18.5
han30gauge Sqm
146 MAT-00869 BMT-F.02 CountryNails 1Kg 63
147 MAT-00870 BMT-F.03 WireNails 1Kg 63
148 Mild Steel Tubes & pipes of
MAT-00871 BMT-F.04 1Kg 66
alldiameters asperIS-1161

24
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
II.SUB- GALVANIZEDSTEELMATERIALS
SECTION
Supplying Galvanized Steel Barbed
149 MAT-00873 BMT-F.07 wireconforming to IS 278 - 1978 : Type 1Kg 88
A -IOWA Type Designation as per
standardspecification
Supplying Galvanized Steel Barbed
150 MAT-00874 BMT-F.08 wireconforming to IS 278 - 1978 : Type 1Kg 86
B -
GliddenTypeDesignationasperstandards
pecification
151 GalvanizedIronflyproofwiremeshofnot 1
MAT-00884 BMT-F.18 240
less than20 gauge Sqm
Hot dipped Galvanised Iron Chain
152 MAT-00886 BMT-F.20 linkmesh 8 gauge- (4.0 mm) as per 1 440
IS:2721-1979:2"x2"(50mmx50mm)-8 Sqm
Gauge
Hot dipped Galvanised Iron Chain 390
153 MAT-00887 BMT-F.21 linkmesh 8 gauge- (4.0 mm) as per 1
IS:2721-1979:2½"x2½"(63mmx63mm) Sqm
-8Gauge
Hot dipped Galvanised Iron Chain
154 MAT-00888 BMT-F.22 linkmesh 8 gauge- (4.0 mm) as per 1 345
IS:2721-1979:3"x3"(76mmx76mm)-8 Sqm
Gauge
Hot dipped Galvanised Iron Chain
155 MAT-00889 BMT-F.23 linkmesh 8 gauge- (4.0 mm) as per 1 240
IS:2721-1979:4"x4"(102mmx102mm)- Sqm
8Gauge
Hot dipped Galvanised Iron Chain
156 MAT-00890 BMT-F.24 linkmesh 8 gauge- (4.0 mm) as per 1 580
IS:2721-1979-PVCCoated-2"x2"(50 Sqm
mmx 50mm)-8Gauge
Hot dipped Galvanised Iron Chain
157 MAT-00891 BMT-F.25 linkmesh 8 gauge- (4.0 mm) as per 1 480
IS:2721-1979-PVCCoated-2½"x2½"(63 Sqm
mmx 63mm)-8Gauge
Hot dipped Galvanised Iron Chain
158 MAT-00892 BMT-F.26 linkmesh 8 gauge- (4.0 mm) as per 1 400
IS:2721-1979-PVCCoated-3"x3"(76 Sqm
mmx76mm) -8Gauge
Hot dipped Galvanised Iron Chain
159 MAT-00893 BMT-F.27 linkmesh 8 gauge- (4.0 mm) as per 1 310
IS:2721-1979-PVCCoated-4"x4"(102 Sqm
mmx102mm)-8Gauge
III.SUB- STAINLESSSTEELMATERIALS
SECTION
160 StainlessSteelTubes,sections,plates,she
MAT-00872 BMT-F.06 1Kg 360
ets&pipesofallsizes&diameters

25
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
for-304 Grade
161 Stainlesssteelflyproofwire meshofnot less 1
MAT-00885 BMT-F.19 490
than20 gauge Sqm
162 to BMT-F.32 ITEMDELETED
170 Ato H
Note:Items BMT-F.01 , BMT-F.31are removed in thesectionFand
are broughtasnewitemsinthe SectionNasBMT-N.80 and BMT-N.81.
G.SECTION FIXTURESFOR DOORS& WINDOWS
I.SUB- TOWERBOLTS
SECTION
171 BrassTowerBolt-10mmBolt(IS:204)100
MAT-00906 BMT-G.01 Each 150
mmLong
172 BrassTowerBolt-10mmBolt(IS:204)150
MAT-00907 BMT-G.02 Each 231
mmLong
173 BrassTowerBolt-10mmBolt(IS:204)200
MAT-00908 BMT-G.03 Each 317
mmLong
174 BrassTowerBolt-10mmBolt(IS:204)250
MAT-00909 BMT-G.04 Each 365
mmLong
175 BrassTowerBolt-10mmBolt(IS:204)300
MAT-00910 BMT-G.05 Each 449
mmLong
Aluminium Tower Bolt-10 mm
176 MAT-00911 BMT-G.06 Each 56
Bolt(I
S:204)75mmLong
Aluminium Tower Bolt-10 mm
177 MAT-00912 BMT-G.07 Each 69
Bolt(IS:204)100mmL
ong
Aluminium Tower Bolt-10 mm
178 MAT-00913 BMT-G.08 Each 84
Bolt(I
S:204)150mmLong
Aluminium Tower Bolt-10 mm
179 MAT-00914 BMT-G.09 Each 103
Bolt(I
S:204)200mmLong
Aluminium Tower Bolt-10 mm
180 MAT-00915 BMT-G.10 Each 124
Bolt(I
S:204)250mmLong
Aluminium Tower Bolt-10 mm
181 MAT-00916 BMT-G.11 Each 144
Bolt(I
S:204)300mmLong
Aluminium Tower Bolt-10 mm
182 MAT-00917 BMT-G.12 Each 387
Bolt(I
S:204)350mmLong
Aluminium Tower Bolt-10 mm
183 MAT-00918 BMT-G.13 Each 490
Bolt(I
S:204)450mmLong
184 MS-PowderCoatedTowerBolt-
MAT-00919 BMT-G.14 Each 24
10mmBolt(IS:204)100 mmLong
185 MS-PowderCoatedTowerBolt-
MAT-00920 BMT-G.15 Each 35
10mmBolt(IS:204)150 mmLong
186 MS-PowderCoatedTowerBolt-
MAT-00921 BMT-G.16 Each 51
10mmBolt(IS:204)200 mmLong

26
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
MS-PowderCoatedTowerBolt-
187 MAT-00922 BMT-G.17 Each 68
10mmBolt(IS:204)250 mmLong
MS-PowderCoatedTowerBolt-
188 MAT-00923 BMT-G.18 Each 85
10mmBolt(IS:204)300 mmLong
II.SUB- HINGES
SECTION
189 MAT-00924 BMT-G.19 BrassButthinges(IS:205)- 75mmLong Each 67
BrassButthinges(IS:205)-100mmLong
190 MAT-00925 BMT-G.20 Each 203

BrassButthinges(IS:205)-125mmLong
191 MAT-00926 BMT-G.21 Each 246

BrassButthinges(IS:205)-150mmLong
192 MAT-00927 BMT-G.22 Each 324

AluminiumButthinges(IS:205)-
193 MAT-00928 BMT-G.23 Each 81
75mmLong
AluminiumButthinges(IS:205)-
194 MAT-00929 BMT-G.24 Each 97
100mmLong
AluminiumButthinges(IS:205)-
195 MAT-00930 BMT-G.25 Each 117
125mmLong
AluminiumButthinges(IS:205)-
196 MAT-00931 BMT-G.26 Each 120
150mmLong
MS-Powder Coated Butt
197 MAT-00932 BMT-G.27 Each 11
hinges(IS:205)-
75mmLong
MS-Powder Coated Butt
198 MAT-00933 BMT-G.28 Each 20
hinges(IS:205)-
100mmLong
MS-Powder Coated Butt
199 MAT-00934 BMT-G.29 Each 31
hinges(IS:205)-
125mmLong
MS-Powder Coated Butt
200 MAT-00935 BMT-G.30 Each 39
hinges(IS:205)-
150mmLong
Providing and fixing stainless
steel(SS-
BMT-G.80 304grade)frictionhingestotheside/to
p hung uPVC windows, ofapproved
201 quality, with necessarystainless
steel screws etc. as perdirection
ofEngineer-in-charge.
202 MAT-05342 BMT-G.80.A 200x19x1.9mm Each 270
203 MAT-05343 BMT-G.80.B 250x19x1.9mm Each 300
204 MAT-05344 BMT-G.80.C 300x19x1.9mm Each 317
205 MAT-05345 BMT-G.80.D 350x19x1.9mm Each 438
206 MAT-05346 BMT-G.80.E 400x19x1.9mm Each 461
III.SUB- DOORHANDLES
SECTION
207 MAT-00936 BMT-G.31 AluminiumDoorHandles(IS:208)75 Each 54
27
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
mmLong
208 AluminiumDoorHandles(IS:208)100mmL
MAT-00937 BMT-G.32 Each 62
ong
209 AluminiumDoorHandles(IS:208)125mmL
MAT-00938 BMT-G.33 Each 92
ong
210 AluminiumDoorHandles(IS:208)150mmL
MAT-00939 BMT-G.34 Each 103
ong
211 MS-Powder Coated Door
MAT-00940 BMT-G.35 Each 32
Handles(IS:208)125mmL
ong
212 MS-Powder Coated Door
MAT-00941 BMT-G.36 Each 45
Handles(IS:208)150mmL
ong
213 MAT-00963 BMT-G.58 Brassfancyhandles150mm Each 299
214 MAT-00964 BMT-G.59 Brassfancyhandles200mm Each 404
215 MAT-00965 BMT-G.60 Brassfancyhandles250mm Each 728
216 MAT-00966 BMT-G.61 Brassfancyhandles300mm Each 930
217 MAT-00967 BMT-G.62 Brassfancyhandles450mm Each 1454
218 KeylesslocksetfortoiletdoorswithCPorPC
MAT-00977 BMT-G.72 Each 310
knobhandles(completeset)
219 Keylesslocksetfortoiletdoorswithbrasskno
MAT-00978 BMT-G.73 Each 819
bhandles
Providing and fixing casement
220 MAT-05347 BMT-G.81 handlemade of zinc alloyed (white Each 187
powdercoated)foruPVCcasementwindo
w withnecessary screwsetc.complete.
IV..SUB- ALDROPS
SECTION
221 MAT-00942 BMT-G.37 BrassAldrop(IS:2681) 300mmlong Each 1087
222 MAT-00943 BMT-G.38 BrassAldrop(IS:2681) 350mmlong Each 2094
223 MAT-00944 BMT-G.39 BrassAldrop(IS:2681) 450mmlong Each 2982
224 AluminiumAldrop(IS:2681)200mmlong
MAT-00945 BMT-G.40 Each 240

225 AluminiumAldrop(IS:2681)250mmlong
MAT-00946 BMT-G.41 Each 284

226 AluminiumAldrop(IS:2681)300mmlong
MAT-00947 BMT-G.42 Each 308

227 MS-PowderCoatedAldrop(IS:2681)200
MAT-00948 BMT-G.43 Each 98
mmlong
228 MS-PowderCoatedAldrop(IS:2681)250
MAT-00949 BMT-G.44 Each 129
mmlong
229 MS-PowderCoatedAldrop(IS:2681)300
MAT-00950 BMT-G.45 Each 154
mmlong

28
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
V.SUB- LATCHES
SECTION
230 MAT-00953 BMT-G.48 AluminiumFlatLatches:200mmlong Each 117
231 MAT-00954 BMT-G.49 AluminiumFlatLatches:250mmlong Each 131
232 MAT-00955 BMT-G.50 AluminiumFlatLatches:300mmlong Each 144
233 MS-PowderCoatedFlatLatches:250mm
MAT-00956 BMT-G.51 Each 55
long
234 MS-PowderCoatedFlatLatches:300mm
MAT-00957 BMT-G.52 Each 70
long
235 MAT-00973 BMT-G.68 Brasslatchheavy300mm Each 573
236 MAT-00974 BMT-G.69 Brasslatchheavy350mm Each 658
237 MAT-00975 BMT-G.70 Brasslatchheavy450mm Each 826
VI..SUB- DOORCLOSURES
SECTION
ProvidingandfixingCastIronBodyBottle
Type Hydraulic Door Closer
238 MAT-00968 BMT-G.63 (IS:3564)withdoublespeedadjustment,wi Each 876
th necessary accessories and
screwsetc.complete
Providing and fixing Aluminium
ExtrudedSectionBody Tubular Type
HydraulicDoorCloser(IS:3564)withdoubl
239 MAT-00979 BMT-G.74 espeedadjustmentwithnecessaryaccess Each 1065
oriesandscrewsetc.complete(Type-1:
forwidthofdoorsup to700mm)

Providing and fixing Aluminium


ExtrudedSectionBody Tubular Type
HydraulicDoorCloser(IS:3564)withdoubl
240 MAT-00980 BMT-G.75 espeedadjustmentwithnecessaryaccess Each 1197
oriesandscrewsetc.complete(Type-2: for
width of doors 701 to 850mm)

Providing and fixing Aluminium


ExtrudedSectionBody Tubular Type
HydraulicDoorCloser(IS:3564)withdoubl
241 MAT-00981 BMT-G.76 espeedadjustmentwithnecessaryaccess Each 1256
oriesandscrewsetc.complete(Type-3: for
width of doors 851 to 1000mm)

VII.SUB-
SECTION FLOORSPRINGS

DoubleactionStainlesssteelcoverplate
242 MAT-00969 BMT-G.64 and cast body iron floor spring (IS6315- Each 1751
Table-1)
DoubleactionBrasscoverplateandcastbra
243 MAT-00970 BMT-G.65 Each 4153
ssbodyfloorspring(IS6315-
Table-1)

29
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Providing and fixing double action
brasscasthydraulicfloorspring(IS:6315-
Table1)fordoorsincludingcostofcutting
244 MAT-00982 BMT-G.77 floors as required, embedding infloors Each 3537
and S.S./ Brass cover plates withbrass
pivot and single piece M.S. Sheetouter
box with slide plate etc.
complete(doorweightcapacityup to
130kgs)
Providing and fixing double action
brasscasthydraulicfloorspring(IS:6315-
Table1)fordoorsincludingcostofcutting
245 MAT-00983 BMT-G.78 floors as required, embedding infloors Each 2555
and S.S.cover plates with brasspivot
and single piece M.S. Sheet outerbox
with slide plate etc. complete
(doorweightcapacity upto 80kgs)
Providingof brass cast body
FloorSpringIS:6315sleekinsizewithth
e
246 MAT-00984 BMT-G.79 S.S. / Brass Cover plates of Length Each 10805
320mm x Breadth 130 mm size along
withtheTopPatch,BottomPatch,DoorLoc
kand Pivot with Double Cylinder
etc.completeforHeavydutyGlassdoors.
VIII MORTICELOCKS
Heavydutymortiselock6/7levers(IS:2209)
247 MAT-00971 BMT-G.66 withPCorCPhandlescompleteset Each 792

248 Heavydutymortiselock6/7levers(IS:2209)
MAT-00972 BMT-G.67 Each 2036
with brassheavyhandles
IX.SUB- OTHERACCESSORIES
SECTION
249 MAT-00958 BMT-G.53 MS-PowderCoated-Door Stoppers Each 45
250 MAT-00962 BMT-G.57 Heavyduty AluminiumDoorstopper Each 53
251 MAT-00951 BMT-G.46 BrassDoorStoppers Each 168
252 MAT-00976 BMT-G.71 Frictionstayhingesforwindows Each 91
253 MAT-00961 BMT-G.56 DeluxewindowstayAluminium Each 122
254 MAT-00952 BMT-G.47 BrassWindowsStay Each 181
255 Supply&fixingdraperyrods(25.4mm)1"x2
MAT-00959 BMT-G.54 RM 108
1GPowdercoatedwith PVCrings
256 Supply&fixingdraperybracket-
MAT-00960 BMT-G.55 pair 402
brasspowdercoated
Providingandfixingzincalloyed(whitepo
257 MAT-05348 BMT-G.82 wdercoated)touch lock for Each 154
uPVCslidingwindowwithnecessarysc
rewsetc.Complete

30
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
ProvidingandfixingsteelrollerforuPVCslid
258 MAT-05349 BMT-G.83 ing windowwithnecessary Each 88
screwsetc.complete.
ProvidingandfixingsteelrollerforuPVCslid
259 MAT-05350 BMT-G.84 ing doorwithnecessary Each 140
screwsetc.complete.
Providingandfixingsteel(whitepowerco
260 MAT-05351 BMT-G.85 ated)crescent lockforuPVC Each 167
slidingwindow/doorwithnecessarysc
rewsetc.complete.

WATERPROOFINGCHEMICALS&ADM
IXTURES
H.SECTION Literature for usage / application
ofconstruction/waterproofingmaterials,
epoxies etc, may be obtained
frommanufacturers.
261 to BMT-H.01 ITEMSDELETED
325 to
except 65except
279 BMT-H.37

279 MAT-01021 BMT-H.37 ITEMDELETED

PreconstructionAntitermiteisaprocessin 1 150
whichchemicaltoxictosubterrean Sqm
termites is apply/ inject
intosoilduringearlystageofbuildingConstr
uction
2.TreatementofsoilBeneaththebuildingan
326 MAT-05352 BMT-H.66 daroundthefoundationsconduct and
chemical use as per BIS -IS6313(Part-
2)2013codespecification&CIBRCregister
edtermiticidewhichcreatesacontinuousch
emicalbarrierbeneaththebuildingwhichkill
sorrepelsterminates&impervioustotremit
e entry

3.Imidacloprid30.5%SC(IS63131)dissolv
e 2.1 Ml/1 liter of water and
applyemulsion/solution@7.5Litres/Squar
emeter (Sqm) of internal, external
verticalsurfaceofthecolums,plinthbeams(
Backfilling)wallsandfloorjunction,external
perimeters, along reatining
wall@5.0Liters/Sqmofthehorizontalsurfa
ceofbasementtopsurfaceofthe

31
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
basementfillingbelowflooringbed(Plinth)
& @ 2.0 Litres/ Line meter atexpansion
joints. The substructure of
adepthof500mmaroundcoulmns&300m
mdeeparoundplinthbeams,basements &
floor filling area
includingexcavationchannelalongthewall
&rodding etc. cost & Conveyance of
allmaterialstothesite,costoflabourfors
parying,roddingetc.completefor
furnished item of work as per
theapproval oftheEngineer-in-charge
ITEMDELETED
327 BMT-H.67

I.SUB- REPAIRINGANDTREATMENT
SECTION WORKS
BMT-H.68 SURFACEPREPARATION
Cleaningof thesurface:
ForWaterproofingtreatment
( Ifthe surface issound &
hardCondition ) The surface mustbe
cleanand sound duly removingof
328 BMT-H.68.A exisitingtretamentsclean from dirt, Sqm 60
MAT-05353
dustandothercontaminationsby
powergrindingwirebrushing,air
blower&jetwatercleaing.
(Ifthe surfaceis detoriatedordamage
/ existing tiles or block laying)
Chippingwith pneumatic
powerchiselingequipmentanduntiltoahci
329 BMT-H.68.B Sqm 150
MAT-05354 evethehardmotherconcretesurface.Duly
removing of debris, cleaning of
thesurfacefromdirt,dustandotherforeign
matters&waterjetcleaning.
if the surface has existing
damagedbituminous felt/ APP
membrane.Chipping and removing of
existingbituminoustarfelt / membrane
withchiseling equipments,grinding /
330 BMT-H.68.C Sqm 100
MAT-05355 wirebrusing the surface dulyremoving
thefeltcompletely. Duly removing
ofdebris,cleaningofthesurfacefromdirt,d
ust and otherforeign matters &
waterjetcleaning.
SPECIALISED
CHEMICALWATERPROOFINGTR
EATMENTSFORTERRACE
WHERVERFLOORINGSURFACEISHA
VING MAJOR HAIR LINE
CRACKSDEVELOPED,SEVERELEAK
AGES

32
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
TAKENPLACEANDREQUIREDTORED
UCE THE
ROOMTEMPERATU
RES- SELF
ASSESSEDTREATMENTSTOIDENTIIF
YEACHLAYER OF TREATMENTS
:REFERTHERATESFORCLEANINGAN
DCRACK FILLINGUNDER THE
HEADOF THE WORKS Item Code
BMT-
H.68SURFACEPREPARATIONSUBHE
ADING:CLEANINGOFTHESURFACEF
ORWATERPROOFINGTREATMENT.
SPECIALISEDFIVELAYERSYSTEMOF
WATERPROOFINGTREATMENT
TO THETERRACE WITH Roofcare-prc5
Systems or equivalent (
ROOFCAREPRC 5 (Armstrong) /
ZORICOAT PFC
5(PMCC)/POWERSAC5L(EBT)/WATER
SHIELD5LWC

a). IstLayerBlackcolouredchemcialtreat
ment :Providngand application
ofonecoatofHighbonding,flexiblebitumin
ouspolyurethaneblendedbituminous
coating with–Roofcare prc5 systems
Confiming to ASTM-G 154 -2000 or
equavalentIst Layer dilutingwith waterat
1 : 1 ratio as a primer
coatataconsumptionof 200mlperSqm.
b). IInd Layer :Providing and laying
ofFibre Mesh 40 GSM,with1
Mtrwidthand50mmoverlapontheprimeds
MAT-05356 urface.
331(a) BMT-H.69 Sqm 529
c). IIIrd Layer Grey coloured coating
:ProvidingandapplicationofonecoatofAcr
ylicrubberizedelastomericflexible
waterproofgrey coating with–
Roofcareprc5systemsASTM-
C836orequavalentorequavalentdilutingw
ith 50% of water at a consumption
of400mlper Sqm.
d) IVthLayer white colured coating
:Providing and application of one coat
ofHigh solid, cold applied, Fibre
reinforcedacrylicelastomericwaterproofm
embrane off white coating –Roofcareprc
5 systemsConfiming to ASTM-G154 -
2000 or equavalentcoating (addthe
waterupto 200ml ) (Consumption
of350mlperSqm).
e) VthLayersuperwhitereflectivecoating
:Applicationofonecoatof100%pure
acrylic solar
reflectivepurewhitecoatingwithRoofcarep
rc5

33
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
systems Confirming to ASTM -C 297
orequavalentsolarrefectivecoatingdiluting
with 20% of water
(Consumptionof300mlperSqm).
Note: THE ABOVE TREATMENT
WILLBEGUARANTEEDFOR5YEARS
SPECIALISEDFIVELAYERSYSTEMOFWAT
ERPROOFINGTREATMENTTOTHETERRA
CEWITHMIXGUARDHR5
System.

Providingandlayingfivelayerswaterproofing
cum heat reflective treatment(MIXGUARD
HR5 or equivalent) over
theold/newroofslab/terrace,allasdirectedby
Department Engineer-in-charge with
thefollowingspecificationandshouldbecompla
inwiththefollowingtechnicalparametersforthe
system-
Density:1.3Gm/cc,Solidscontent:68%±2%by
weight, Elongation at break ASTM D
638:200%(forthesystem),Adhesiontosubstrat
eASTMD4541:>1.5N/mm2,Water
penetration DIN 1048: no leak at
7bars,TearresistanceASTMD1004-
76:17N/mm2, Tensile strength ASTM D 412-
87:6.0N/mm2

a)FirstLayer-
SupplyandApplypenetrativecumbondingprim
331 (b) MAT-08738 BMT-H.69 erasbaseprimercumsealercoat
Sq.m 529
(b) usingMIXPRIMEAC100orequivalentmodified
withwaterand cement at the ratio 2:1:3
(MIXPRIMEAC 100 : water : cement) by
volume with aslow speed mixer
machine.This compoundshall be applied
with sufficient thickness tocover the
holes/pores/cracks @ 1.000 Liter
/SQM(0.350LtofMIXPRIMEAC100/
SQM)andtherawprimershouldbecomplain
with ASTM 4541 and the
Solidcontent49%+2%

b)SecondLayer–
Supplyandapplyof2x2mmweldedwithalkaline
resistantcoated
/non-
woven40GsmvergingfibermeshMIXMATGF
M50orequivalentforaminimum over lap of
100 mm embedded intheprimercoat

c)ThirdLayer-
Supplyandapplyofbondingcumwatertightacry
lichighviscous white primerMIXPRIME AC
orequivalent @ 0.250 Kg / SQM (dilution
ormodificationnotrecommended)should

34
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
be
complainwithDensity:1.1gm/cc,Solidscontent
:50%±2%byweight,Elongationat break
ASTM D 638: >300%, Adhesion
tosubstrateASTMD4541:>1N/mm2,
TensilestrengthASTMD638:>1.5N/mm2,
Reduction in chloride ion ingress:94%@28
days

d ) Fourth Layer – Supply and apply of


highelastomericacrylicwaterproofingcumwea
therproofhighviscouswhiteliquidmembrane
MIXGUARD HR or equivalent@ 0.500 Kg /
SQM (dilution or modificationnot
recommended) should be complain
withDensity: 1.30 gm/cc , Solids content:
68% ±2% by weight, Elongation at break
ASTM D638: 400%, Tensile strength ASTM
D 412:1.8N/mm2, Adhesion to substrate
ASTM
D4541:>1N/mm2,WaterpenetrationDIN1048:
no leak at 7 bars (+ve side),
WatervaportransmissionASTME96:19g/m2/d
ay, Crack bridging ASTM C836:No
cracksupto2mmthick.

E ) Fifth Layer - Supply and apply of


fiberreinforcedflexible highbridepure
acrylicmodifiedwaterproofing cum heat
reflectivehighviscouswhiteliquidmembraneMI
XGUARDHRXtraorequivalent@
0.500 Kg / SQM (dilution or
modificationnotrecommended)Density:1.3g
m/cc
Solidscontent:68%±2%byweight,Elongation
at break ASTM D 638: 200% ,Adhesion to
substrate ASTM D 4541:
>1.3N/mm2,WaterpenetrationDIN1048:nolea
kat7bars,TearresistanceASTMD1004-76:
15N/mm2 , Tensile strength ATMD412-
87:3.0N/mm2,Solarreflectance–
ASTMG173–
92%,WatervaportransmissionASTM E 96 –
2
19 Kg / M /day.
Note: -
1 ) No dilution or
modificationrecommendedforitemNo.b,
c,dande.
2 )Allmaterialsshouldbeprocured asperthe
consumption with respect of the
workorder.
3 )Theapplication shouldbecarried outbyan
approvedagency.
4 ) The contractor should provide 5
yearsmaterialwarranteefromtheManufacturer
and 5 year warrantee from the applicator
orcombined
WHEREVERFLOORINGSURFACEIS
35
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
HAVINGHAIRLINECRACKSDEVELOP
ED,SEVERELEAKAGESANDFOUNDV
ERYSLIGHTLYMORTARDEBONDED
WITHORIGINAL SLAB - TAKEN
PLACE:REFER THE RATES FOR
CLEANINGAND CRACK
FILLINGUNDERTHEHEADOFTHEWO
RKSRAINSEALFRC SPECIALISED
HIGH
STRENGTHFIBREREINFORCEDACRY
LICELASTOMERICANDHEATRESIST
ANTLIQUIDMEMBRANE
COATINGCHEMICALSConfirmedAST
M C 836/89A & ASTMC 297
FORTERRACE.
SPECIALISEDHIGHSTRENGTHCELLU
LOSEFIBREREINFORCEDACRYLICEL
ASTOMERICLIQUIDMEMBRANE
COATING
FOR
TERRACE :
a). Providingandapplicationofonecoat
ofHigh Solid,Cold applied
AcrylicElastomericLiquid Membrane
Coatingwith–
RAINSEAL(Armstrong)/POWERnCOAT
EWC(EBT)/DECKGUARD E 2000
(Fosroc)
/ZORICOATEWC(PMCC)/SIKAGARD55
0W/WATERSHIELD
EWC 600 diluting with waterat 1 :
0.50ratio as a primer coat at a
332 MAT-05357 consumptionof200mlperSqm.
BMT-H.70 Sqm 510
b). Providing and laying ofNon
wovenpolysterreinforcedfibremeshof40G
SM,with1 Mtrwidthand 50mmoverlapon
theprimedsurface.

c) Providing and application of


onecoatofHighstrengthcellulosefibrereinf
orcedAcrylicElastomericLiquidMembran
ecoatingwith-
RAINSEALCFR(Armstrong/ZORICOAT
CF(PMCC) / POWER n COAT CR
(EBT)WATERSHIELDFLEXCR/FIBRER
EINFORCED
ACRYLIC
ELASTOMERICCOATINGS(Fosroc)dilut
ing with waterat 20%as a
basecoatapplicationataconsumptionof40
0mlperSqm.
WHERVERFLOORINGSURFACEISHA
VINGHAIRLINECRACKSDEVELOPED,
SEVERELEAKAGESANDFOUNDSOM
EPLACESMORTARDEBONDEDWITH
ORGINALSLAB-TAKENPLACE:

36
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
REFER THE RATES FOR
CLEANINGAND CRACK
FILLINGUNDERTHEHEADOFTHEWO
RKSBMT-H.68©
andBMT-
H.83chemicalcomplieswithASTMC297
.

SPECIALISED
HIGHPERFORMANCEACRYLICPOLY
MERMODIFIEDELASTOMERIC
CEMENTITIOUS
WATERPROOFCOATINGTOTHETERR
ACE

a). Providingandapplicationofonecoato
fHighperformanceAcrylatepenetrativewa
terbarrierprimer–
ROOFBONDBCS(Armstrong)/ZORIBON
D BCS(PMCC) / POWER
nPENETRATE(EBT)/WATERSHIELDC
P/DECKGUARDCP(Fosroc)
/SIKAGARD705 L(Sika)diluting
withwater at 1 : 0.50 ratio as a primer
coatataconsumptionof 200mlperSqm.

b). Providing and laying ofNon


wovenpolysterreinforcedfibremeshof40G
SM,with1 Mtrwidthand 50mmoverlapon
theprimedsurface.

333(a) MAT-05358 BMT-H.71 c) Providing and application of Sqm 475


onecoatof Two part system of high
performanceacrylicpolymermodifiedelast
omericcementitiouswaterproofcoatingR
OOFBOND RFX (Armstrong )
/POWERnCOATRFX(EBT)/BRUSHBON
D RFX
(Fosroc)/ZORIBONDRFX(PMCC)/WAT
ERSHIELDRFX/SIKAGARD550
U 2K (Sika)mixingofpowderandliquidas
perpacking at 1:2
ratio.(addthewaterupto200ml)ataconsum
ptionrate of300 Grams mix.

d).ProvidingandapplicationofonecoatofT
wopartssystemfibreReinforced Acrylic
Cementitious
Coatingswith–
ROOFBONDFRC(Armstrong)
ZORIBOND FRC ( PMCC)
/POWERnBONDFRC(EBT)/WATERSHI
ELDBONDFR/Fosroc
mixingofpowder andliquidas perpacking
at 1:2 ratio(add the water upto200ml )
ata consumption rate of300Gramsmix.

37
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
SPECIALISED HIGH
PERFORMANCEACRYLIC POLYMER
MODIFIEDELASTOMERIC
CEMENTITIOUSWATERPROOFINGSYSTE
MCOATINGTO THE WET AREA / TOILET /
BATHROOM.
a)FirstLayer-Supply andApplypenetrative
cum bonding primer as baseprimer cum
sealer coat using MIXPRIMEAC100 or
equivalent modified with waterand cement at
the ratio 2:1:3 (MIXPRIMEAC 100 : water :
cement) by volume with aslow speed mixer
machine.This compoundshall be applied with
sufficient thickness
tocovertheholes/pores/cracks@1.000Liter/SQ
M(0.350Ltof MIXPRIME AC100 /
SQM) and the raw primer should
becomplain with ASTM 4541 and the
Solidcontent49%+2%

b ) Second Layer – Supply and apply of 2


x2mmweldedwithalkalineresistantcoated
/ non-woven 40 Gsm verging fiber
meshMIXMAT GFM 50 or equivalent for
aminimumoverlapof100mmembeddedinthepr
imercoat

MAT-08754 BMT- c ) Third Layer -Supply and apply of firstcoat


333(b) Sq.m 475
H.71(b) of two component (Powder +
Liquid)systemofhighperformanceacrylicpolym
ermodified elastomeric
cementitiouswaterproofing system
MIXGUARD ACorequivalent @ 1.000 Kg /
SQM ( mix thepowder and liquid with the help
of a slowspeed mixer for a period of 2 to 3
minutesup to get a homogeneous mix-
dilution ormodification not recommended)
should becomplain with BS1881
Part51983(ISAT
476 Part6),DIN1048Part51991,BSEN
12390-82000,ASTM D 412-92

d ) Fourth Layer –Supply and apply ofsecond


coat of two component (Powder
+Liquid)systemofhighperformanceacrylicpoly
mermodifiedelastomericcementitiouswaterpr
oofingsystemMIXGUARDACorequivalent @
1.000 Kg / SQM ( mix thepowder and liquid
with the help of a slowspeed mixer for a
period of 2 to 3 minutesup to get a
homogeneous mix- dilution ormodification
not recommended) should becomplainwith
BS1881 Part51983(ISAT

38
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
476 Part6),DIN1048Part51991,BSEN
12390-82000,ASTM D 412-92.
Note: -
1 ) No dilution or
modificationrecommendedforitemN
os.b,c,dande.
2 )Allmaterialsshouldbeprocured
asperthe consumption with respect of
the workorder.
3 )Theapplication shouldbecarried
outbyan approvedagency.
4 ) The contractor should provide 5
yearsmaterial warrantee from the
Manufacturerand5yearwarranteefromth
eapplicatororcombined
WHERVER FLOORING SURFACE
ISHAVING MAJOR HAIR LINE
CRACKSDEVELOPED,SEVERE
LEAKAGESTAKEN PLACE AND
REQUIRED TOREDUCE THE
ROOMTEMPERATURES-
Sqm 540
BMT-H.72 SELFASSESSEDTREATMENTS TO
334 MAT-05359 IDENTIIFY EACHLAYER OF
TREATMENTS :REFERTHE RATES
FOR CLEANING ANDCRACK
FILLINGUNDER THE
HEADOFTHEWORKS
a). Providngand application of one
coatofHighbonding,flexiblebituminouspol
yurethane blended black coating
withROOFCARE PU (Armstrong )
/POWERnCOATPU(EBT)/NITOBONDP
OLYURETHANE BLENDED
BITUMENCOAT(Fosroc)/ZORICOATPU
(PMCC)/SIKALASTIC 450
L/WATERSHIELD ELASTIC 450 PU
(PolyurethaneblendedBituminouswaterp
roofcoatingsystem)ComplieswithASTM8
36 - DN 1048 diluting withwaterat 1 : 1
ratio as a primer coat at aconsumptionof
200ml perSqm.
b). Providing and laying ofNon
wovenGEOFabric 40GSM,
with 1 Mtrwidthand
50mmoverlapontheprimedsurface.
c). Providingandapplicationofonecoatof
Acrylic rubberizedelastomericflexible
waterproofgrey coating with–
RAINSEALRWC902(Armstrong)/POWE
RnCOATRC/ZORICOATRC(PMCC)/(Fo
sroc)/WATERSHIELD
RC FLEXComplies with ASTM G 154 -
2000dilutingwith50%ofwaterataconsump
tionof 400mlperSqm.
d) Providing and application of one
coatofHighsolid,coldapplied,Fibrereinfor
ced acrylic elastomeric
waterproofmembraneoffwhitecoating–
39
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
ROOFCOATFRC(Armstrong)/ZORCOATFC
(PMCC)/POWERnFRX2(EBT)/WATERSHIE
LDFRC/
DECKGUARD FRC (Fosroc )Complieswith
ASTM C 297 (addthe
waterupto200ml)(Consumptionof350mlperS
qm ).
e)Application of one coatof100%pure acrylic
solar reflectivepure whitecoatingwith-
ROOFCARECOOL(Insulator) / POWER n
COOL (EBT) /BRUSHBOND COOL
COAT(Fosroc)/ZORIS
HIELDXL(PMCC)/SIKACOOLCOAT(Sika)
//WATERSHIELD COOL COAT
dilutingwith20%ofwater(Consumptionof300m
lperSqm).

FOR WATERPROOFING
OFPORTABLEWATERTANK
S/RESERVOIRS/SUMP/TERRACE/SIDE
WALLS
:REFER THE RATES FOR
CLEANINGAND CRACK
FILLINGUNDERTHEHEADOF THEWORKS
SPECIALISED
ACRYLICCEMENTI
TIOUS
ELASTOMERICWA
TERPROOF COATING
TREATMENTComplieswithASTMC
MAT-05360 297 :
335 BMT-H.73 Sqm 350
ProvidingandApplicationof two
coatsofAcryliccementitiouselastomericwater
proofcoatingwith-Roofcoatorequavalentlike
high elastomeric
acrylicpolymermodifiedcementiitiouswaterpr
oofsystem.
FOR WATERPROOFING OF TERRACE
/ SIDE WALLS :REFER THE RATES
FOR CLEANING AND CRACK FILLING
UNDER THE HEAD OF THE WORKS

SPECIALISED ACRYLIC CEMENTITIOUS


ELASTO MERIC WATER PROOF
COATING
TREATMENTComplieswithASTMC
297:
336 MAT-05361 BMT-H.74 Sqm 390
ProvidingandApplicationof two
coatsofAcryliccementitiouselastomericwater
proof coatingwith -
ROOFCOAT(Armstrong)POWERnCOAT(EB
T)/BRUSHBOND(Fosroc)ZORICOAT(PMCC
)/SIKATOPSEAL107(Sika)/

40
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
WATERSHIELD COAT PClike
highelastomericacrylicpolymermodifiedc
ementiitiouswaterproofsystem.
WHERVERHIGHFLEXIBLEHIGHBOND
EDNECESSARYFORWATERPROOFIN
GOFTERRACE/SLOPEDROOFS / ACC
SHEETSetc.,FORAGUARANTEEOF5Y
EARSREFER THE RATES FOR
CLEANINGANDCRACKFILLINGUNDE
RTHEHEADOF THEWORKS

SPECIALISEDHIGHSOLID,COLDAPPLI
ED,ACRYLICWATERPROOFCOATING
TOTHEEXTERNALWALLS
Acrylicelastomericwaterproofexteriorcoa
tings Complies withASTMC 836 /89A :

Providing and application of two coats


ofHighsolid,coldapplied,AcrylicElastome
337 MAT-05362 BMT-H.75 ricLiquidMembraneCoatingwith – Sqm 390
RAINSEAL (Armstrong )/ POWERn
COAT EWC (EBT) / DECKGUARD
E2000(Fosroc)/ZORICOATEWC(PMCC
)/SIKAGARD550W/
WATERSHIELDEWC600dilutingwith20
%ofwatermixingwithrequiredcolourstaine
rs.

WHEREVERREQUIREDFORWATERP
ROOFINGOFTERRACE/SLOPEDROO
FS / ACC
SHEETSetc.,FORAGUARANTEEOF3Y
EARSREFER THE RATES FOR
CLEANINGANDCRACKFILLINGUNDE
RTHEHEADOF THEWORKS
SPECIALISEDHIGHBONDING,FLEXIB
LE
BITUMINOUS
POLYURETHANE
BLENDEDBI
TUMINOUSCOATINGComplieswithAS
TMC 836- DN1048:

MAT-05363 Providngandapplicationoftwocoatsof
Highbonding,flexiblebituminouspolyu
338 BMT-H.76 Sqm 360
rethaneblendedbituminous coating
with
ROOFCAREPU(Armstrong)/POWERn
COATPU (EBT) / NITOBOND
POLYURETHANE
BLENDED
BITUMEN COAT (Fosroc)/
ZORICOATPU(PMCC)/SIKALASTIC45
0L/WATERSHIELD ELASTIC 450 PU
dilutingwith20%of water.

41
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
EXPANSIONJOINTTREATMENT:
Prepration of the surface: For
existingexpansion joint treatment :

Chippingoftheexisitingtreatmentsovertheexpa
nsionjointsconcrete/brickmasonrywithpneumat
icpowerchiselingequipmentanduntiltoahcievet
hehardmotherconcretesurface.Chippingandre
339 MAT-05364 BMT-H.77 movingofexisting bituminousmastic boad RMT 250
upto25mm deep.
Duly removing of debris, cleaning of
thesurface from dirt, dust and
otherforeignmatters

SPECIALISED
POLYSULPHIDESEAL
ANTTREATMENTTOTHEEXPANSIONJOINT
SONTERRACE:
(Size:25mmx12mm)

Applicationofonecoatof-Highperformance
specially
designedSBRlatexpolymerbasedbondingagen
t–
ROOFBONDSBR(Armstrong)/POWERnBON
DSBR(EBT)/NITOBONDSBR(Fosroc)ZORIB
ONDSBR(PMCC)/SIKALATEX(Sika)WATERS
HIELD BOND SBRASTM - C920-
95/DIN18549TT-S-00227E or
equivalentmixing with cement as
permanufacturers
c].Providingandapplicatio
n of Acrylic Polymer modifiedreinstatement
MAT-05365
340 BMT-H.78 concrete/mortaradmixtur RMT 650
ewith-
ROOFCRETEAR(Armstrong)/ZORIGROUTC
MG(PMCC)/POWERnGUARDARM(EBT)/WA
TERSHIELDAR/ Fosroc
to finish the damaged edges of joint
andmaking the groove.d].Providing andfixing
of masking tape on top of the jointboth
sides.e].Providing and fixing
ofBackupsupportmaterialofPolyethelene
foamto leave the depthof 12mm on the joint.
f].Providing andapplication of one coat of
polysulphideprimerwith–
Polysulphideprimeroninner edge on joints.
g].Providing
andapplicationofTwopartPolysulphidesealant
to a widthof 25mm and 12mmdepthwith-
ROOFSEALPS(Armstrong
)/ POWERnSEALPS (EBT)
/NITOSEALPS200(Fosroc)/ZORISEAL PS
(PMCC) / SIKA
42
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
POLYSULPHIDE (Sika) /
WATERSHIELDPSComplieswithBS425
4 - 83 or equavalent with putty
knifeandneatfinish.h].Removingofmaskin
gtapeandprovidingandapplicationoftwoc
oatsofAcrylicelastomeric cementitious
coating with -ROOFSEAL PS
(Armstrong ) /POWERn SEAL PS(EBT)
/NITOSEAL PS
200(Fosroc)/ZORISEALPS(PMCC)/SIK
APOLYSULPHIDE(Sika)/WATERSHIEL
D PS

FORARRESTINGWATERFLOWLEAKA
GES,LEAKAGESOFCONSTRUCTION
JOINTS
OFRESERVOI
RS/PUMPROOMS/POWERHOUSE/PE
NSTOCK/CANAL DUCTS AND OTHER
WATERRETAINING
STRUCTURES
EXECUTIONINTHEPRESENCEOFWAT
ER.
LABOUR CHARGES
FORSPECIALISEDEX
PANSIVEACQUA–
REACTIVEWATERBARRIERGROUTIN
G

(1). DrillingofholeswithElectricalDrilling
machineuptotherequireddepth
i.e.,(12mm to 14mm dia sizedholes)

(2). Fixingofpressureretainingaluminu
m/steelpackersfixingwithInstantsettingle
akproofpluggingcompoundWONDERSE
ALPLUG(Armstrong ) / POWER n
PLUG(EBT) /RENDROC PLUG (Fosroc)
/ZORIPLUG(PMCC/SIKAPLUG
341 MAT-05366 BMT-H.79 Each 250
(Sika)WATERSHIELDPLUG

(3). GroutingofholeswithAirCompresse
d Injectionequipment withsingle
component
aliphaticpolyurethane
groutcompound-RAPIDSTRONG
GROUT PU
(Armstrong)POWERnGROUTPU(EBT)/
NITOFILUR60WS63(Fosroc
)/ZORIGROUTPU(PMCC)/WATERSHIE
LDGROUTPU
(4). After removing the pipes sealing
oftheholeswithpolymerputty–
ROOFCRETE AR SYSTEMS
(Armstrong)/ ZORIGROUTCMG

43
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
(PMCC)/POWERnGUARDARM(EBT)/W
ATERSHIELDAR/ Fosroc
withCement.
Supplyofchemicalsforspecialisedexpansi
veaquareactivewaterbarriergrout-
RAPIDSTRONGGROUTPU
342 MAT-05367 BMT-H.80 (Armstrong)POWERnGROUTPU(EBT)/ Kg 1500
NITOFILUR60WS63(Fosroc
)/ZORIGROUTPU(PMCC)/WATERSHIE
LDGROUTPU
FOR STRENTHENING AND SEAL
THEPOROSITYOFTHECONCRETETO
ARREST THE
LEAKAGES,DAMPNES
S,LEAKAGESOFCONSTRUCTION
JOINTSFORTERRACE/
CEILING/RCCRETAININGWALLS/BAS
EMENTFLOORINGS/WATERTANKS/R
ESERVOIRS /TOILETS etc.,
SPECIALISED INJECTION
GROUTINGWITHCEMENTANDFREEF
LOWADDITIVES:
a].Drilling of holes with power
drillingmachine to the required depth
[12mm to14mmdiaholes]
b].FixingofRubberNozzleswithcementan
dquicksetting,Rapidhardening
compound putty -
Rapidstrong qs orequivalent.
c].Grouting of holes with 140 PSI
GroutpumpwithcementslurrymixingwithS
pecialized Free flow, Non-shrink
Groutadditive-
RAPIDSTRONGGROUTADMIX(Armstro
343 MAT-05368 BMT-H.81 ng)/POWERnGROUT ADMIX(EBT) Each 150
/CEBEX100(Fosroc )/ ZORIGROUT
GP1(PMCC)
/SIKAGROUTANCHKORNSQ(Sika)
/WATERSHIELD GROUT ADMIXi.e.,
250Gramsperbagof50KgsCementaddre
quiredwatertomakeslurryform.
d]. After completion of grouting,
RemovetheRubbernozzles
e].Latersealingoftheholewithpolymercem
entputty-ROOFCRETEAR (Armstrong )
/ZORIGROUT
CMG(PMCC)/POWERnGUARDARM(E
BT) / WATERSHIELD AR
/FosrocNITOBONDAR+ Cement.
FOR STRENTHENING AND SEAL
THEPOROSITYOFTHECONCRETETO
ARREST THE
LEAKAGES,DAMPNES
S,LEAKAGESOF

44
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
ONSTRUCTION JOINTS :

(FORTERRACE/CEILING/RCCRETAINI
NGWALLS/BASEDMENTFLOORINGS/
WATERTANKS/RESERVOIRS
/TOILETSetc.,)
SPECIALISED INJECTION
GROUTINGWITH CEMENT
ANDCRYSTALLIZATIONADMIXTURE
S:
a].Drillingofholeswithpowerdrilling
machine to the required
depth[12mmto 14mmdiaholes]
b].Fixing of Rubber
Nozzleswithcementandquicksetting,R
apidhardeningcompoundputtyRapids
trongqsorequavalent
c].Grouting of holes with 140
PSIGroutpumpwithcementslurrymixin
344 MAT-05369 BMT-H.82 Each 225
g with
Specializedcrystallizati
oncompound-Roofexgpor
equavalent@5% by weight ofcement.
d]. Aftercompletionofgrouting,
Removethe Rubbernozzles
e].Latersealingoftheholewithpolymerc
ementputty-ROOFCRETEAR
(Armstrong ) /ZORIGROUT
CMG(PMCC)/POWERnGUARDARM(E
BT) / WATERSHIELD AR
/FosrocNITOBONDAR+Cement

CRACKSATTERRACE/BEAM&WALLS
JUNCTIONS - SEALING
THEJOINTSWITHPOLYURETHANESE
ALANT:

SPECIALISED
POLYURETHANE
SEALANTTREATMENT:
a). Making‘’U”Groove(widthanddeptho
f6mmx 6mm)
345 MAT-05370 BMT-H.83 b). Fillingofthegroovewithpolyuretha RMT 330
nesealant – ROOFSEAL
PU(Armstrong)/POWERnSEALPU(EBT)
/THIOFLEX600(Fosroc)/ZORISEALPU(
PMCC)/SIKAFLEXPRO -3 WF (Sika )
WATERSHIELD PU3
CRACKS AT INTERNAL /
EXTERNALWALLS-
SEALINGTHECRACKSWITH
ACRYLIC
CAULKINGCOMPOUND

45
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
SPECIALISED ACRYLIC
CAULKINGS
EALANTTREATMENT:
a). Making‘’U”Groove (widthand
depthof 6mmx6mm)
346 MAT-05371 BMT-H.84 b).FillingofthegroovewithAcryliccaulking RMT 180
compound-WONDERSEALXL (Armstrong
)/ POWER nSEAL
XL(EBT)/NITOSEAL(Fosroc)/WATERSHI
ELDXL/ZORISEALXLLATEX(PMCC)

Providing and fixing of expansion joint


system related with floor location: The
joints system will be of extruded
aluminum base members, self aligning /
self centering arrangement and support
plates etc. as per ASTM B221-02. The
system shall be such that it provides floor
to floor /floor to wall expansion control
system for various vertical localtion in
load application areas that
accommodates multi directional seismic
movement without stress to it’s
components. System shall consist of
metal profiles with a universal aluminium
base member designed to accommodate
various project conditions and finish floor
treatments. The cover plate shall be
347 MAT-08739 BMT-H.128 designed of width and thickness required RMT 6640
to satisfy projects movement and loading
requirements and secured to base
members by utilizing manufacturer’s pre-
engineered self-centering arrangement
that freely rotates / moves in all
directions. The Self – centering
arrangement shall exhibit circular sphere
ends that lock and slide inside the
corresponding aluminum extrusion cavity
to allow freedom of movement and flexure
in all directions including vertical
displacement. Provision of Moisture
Barrier Membrane in the Joint System to
have watertight joint is mandatory
requirement all as per the manufactures
design (Material shall confirm to ASTM
6063.) (Floor Joint of 200 mm gap)
Providing and fixing of expansion joint
system related with wall joint (internal/
external) location: The joints shall be of
extruded aluminum base members, self
aligning / centering arrangement and
support plates as per ASTM B221- 02.
348 MAT-08740 BMT-H.129 The material shall be such that it provides RMT 4450
an Expansion Joints system suitable for
vertical wall to wall / wall to corner
application, both new and existing
construction in buildings &

46
BasicRat
e forSoR
S.No CFMScode ItemCode Descriptionofitem Unit 2021-
22 (Rs.)
1 2 3 4 5
complexes with no slipping down
tendency amongst the components of the
Joint System. The Joint System shall
utilize light weight aluminium profiles
exhibiting minimal exposed aluminium
surfaces mechanically snap locking the
multi cellular to facilitate movement.
(Material shall confirm to ASTM 6063.)
(Wall Joint of 200 mm gap)

349 Providing and fixing of expansion joint


system of approved make and
manufactures for various roof locations:
The joints shall be of extruded aluminium
base members with self aligning and self
centering arragement support plates
asper ASTM B221-02. The system shall
be such that it provides water tight roof to
roof / roof to corner joint cover expansion
control system that is capable of
accommodating multi directional seismic
movement without stress to its
components. System shall consist of
metal profile that incorporates a universal
aluminium base member designed to
accommodate various project conditions
and roof treatments. The cover plate shall
be designed of width and thickness
required to satisfy movement and loading
requirements and secured to base
members by utilizing manufacturer’s pre-
engineered self-centering arrangement
that freely rotates / moves in all directions.
The Self centering arrangement shall
exhibit circular sphere ends that lock and
slide inside the corresponding aluminum
extrusion cavity to allow freedom of
movement and flexure in all directions
including vertical displacement. The Joint
System shall resists damage or
deterioration from the impact of falling ice,
exposure to UV, airborne contaminants
and occasional foot traffic from
maintenance personnel. Provision of
Moisture Barrier Membrane in the Joint
System to have water tight joint is
mandatory requirement. Material shall
confirm to ASTM 6063.

350 MAT-08741 BMT-H.130 Roof Joint of 200 mm gap RMT 4925

Roof Joint of 250 mm gap


351 MAT-08742 BMT-H.131 RMT 6200

47
BasicRat
CFMScode ItemCod Unit e forSoR
S.No Descriptionofitem
e 2021-
22 (Rs.)
1 2 3 4 5

II.SUB- INTERGRAL
SECTION WATERPROOFINGCOMPOUND
Integral Cement Waterproofing
Admixture for Concrete Slabs and
BMT- 1Ltr 190
352 MAT-05372 mortar plastering works. ( Dosage :
H.85
100ml Per bag of 50 Kgs Cement)
Complies with I.S. 2645-2003
Liquid Concentrated Micronized
Cement waterproofing
Compound for Slabs, mortar
BMT- plastering and water retained 1Ltr 120
353 MAT-05373 H.86 structures. (Dosage : 500ml
per bag of 50 Kgs Cement )
Complies with I.S. 2645-2003
II.SUB- PLASTICIZERS AND WATER
SECTION REDUCING AGENT

Concrete plasticizers and


Waterreducing admixture (not air
entrainingagent)(Dosage: 15-
20mlperbagof50 Kgs Cement )-
Complies withI.S.9103-99
354 MAT-05374 BMT-H.87 Idealtouseasconcreteadmixture 1Ltr 200
forworkabilityretension of slump
andcontrol water cement ratio of M 20
+grade concrete for slabs /roads
worksand otherconcreteworks

SUPERPLASTICIZERSANDWATERRE
DUCING CONCRETEADMIXTURES

Super plasticizer and water


reducingconcrete admixture base on
LignoSulphide Complies with IS 9103
&ASTMC494(Dosage:200mlto300mlperb
agof 50Kgs Cement )
355 MAT-05375 BMT-H.88 1Ltr 70
For M25 + grade concrete works likeRoad
Projects / Canal linings/ Dams
/Reservoirs/Building’sconcreteworks.

Highperformancesuperplasticizerandwat
er reducingadmixture based
356 MAT-05376 BMT-H.89 onlignosulphideandnapthaleneblended 1Kg 75

48
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Complieswith9103/4-
99(Dosage:300ml to 500ml Per Bag
of 50 KgsCement)
For M30+ grade concrete works
likeRoad Projects / Canal linings/ Dams
/Reservoirs/Building’sconcreteworks.
Highperformancesuperplasticizerandw
ater reducingadmixture based
onnapthalene blended
Complieswith9103/4-
99(Dosage:300ml to 500ml Per Bag
357 BMT-H.90 of 50 KgsCement) 1Kg 80
MAT-05377
For M40+ grade concrete Works
likeroad projects / Canal linings / Dams
/Reservoirs/Building’sconcreteworks

SELFCOMPACTINGCONCRETE
ADMIXTURES
High strength super plasticizers
andwaterreducing agent based
onpolycarboxylic technology.
358 MAT-05378 BMT-H.91 ComplieswithIS9103/ASTMC494(300 1Kg 110
mlto1LtrPerBagof50KgsCement)
For M-40+ + concrete structures
incoastalareas,forearlyhighstrength.
RETARDINGADMIXTURES
Superplasticizer,highrangewaterre
ducingand retarding
concreteadmixtureofnapthaleneble
nded.
MAT-05379 (Complieswith9103-
359 BMT-H.92 1Kg 85
99)(Dosage:300ml to 500ml Per bag
of 50 KgsCement)
Fordelayingof
initialsettingtimeandM40+Gradeconcret
eworks.
CORROSIONINHIBITOR ADMIXTURE
High strength super plasticizer
andcorrosion inhibitor for
concrete(Complies with IS 9103-99 &
EN 1504-9Method11.3)(Dosage
:200mlto500mlPerBagof50Kgs Cement)
For Concretingunder
360 MAT-05380 BMT-H.93 extremecorrosioneffectedareas/coastal 1Kg 95
areas
/industrialconstructionstoprotectth
esteelreinforcement.
Anti Corrosion and leak proof
CrackProof,WaterProof,ConcreteHarde
nerAdmixtureliquid.
AIRENTRAINING AGENT
361 MAT-05381 BMT-H.94 Hi-powerconcentratedAirEntraining, 1Ltr 160

49
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Plasticizing&WaterreducingcompoundC
omplies withIS 9103-99 & ASTM C260
(Dosage 20ml per bag of 50
KgsCement)
Idealto
usefortheconstructionofBridges,
Barrages, Dams,
Tunnels,Piles,Foundations,Towers
etc.,
Two component High Power
PolyesterResin Anchor Grout
CompoundComplieswithASTM-
827/SNF.CRDC-621
362 MAT-05382 BMT-H.95 (Yield0.5 Ltrs / 1 Kg Pack ) 1Kg 325
ForAnchoring/fixthesteelbarsintother
ocks, concrete for
foundations,extensionofconcrete.
IV. SUB- GROUTS
SECTION
Non-
shrinkFreeflowhighstrengthprecisio
ngrout
363 MAT-05383 BMT-H.96 ComplieswithBS1881Part1161983.For 1Kg 34
machinery / thin sections ofconcrete
jointsFilling.

Low viscosity Epoxy


resininjectiongrout -Two parts
system.ComplieswithBS6920/ASTM8
364 MAT-05384 BMT-H.97 81-78(Density 1Kg 800
1.07KgPerLtr)
ForStructuralstrengthening,fillingofho
neycomb/voids intheconcrete.
Non-
shrink,freeflow,highstrengthgrouta
MAT-05385 dmixture
365 BMT-H.98 1Kg 60
Dosage:250GramsPer
Bagof50KgsCement.
(ComplieswithB.S.1881Part1161983)
Highperfomrance,Highbuildexpansiveac
366 BMT-H.99 qua-reactive water 1Kg 1500
MAT-05386 barrierpolyurethanegrout.
V. SUB- BONDINGAGENTS
SECTION
Acrylicbasedbondingadhesive(Mix:1:1
ratioofcement)
Coverage:50SFT/Ltr/CoatDependingon
367 MAT-05387 BMT-H.100 thesubstrate 1Ltr 150
Onterraceoldconcretetonewmortar/scre
ed.

Styrene butadiene rubber


368 MAT-05388 BMT-H.101 basedbondingagentformortar/concr 1Ltr 450
ete
50
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
(Mix:1:1ratioofcement)
Forceiling
/concreterepairsandbonding.
Coverage:50SFT/Ltr/CoatDependingon
thesubstrate
Structural element concrete
bondingagentold to new concrete
epoxybonding agent : (Two
PartssystemofEpoxy Bonding
369 MAT-05389 BMT-H.102 adhesive)Complies withASTM-C 1Kg 870
881Coverage :20 – 25 SFT / Kg
/CoatFor Structural concrete repairs
/bonding.

VI. SUB- SEALANTS


SECTION
Single component polyurethane
sealant(Gungrade/PourGrade)Complis
with:ASTM C 920 -95 Type S / Grade
NS,Class25,andBS;5212
370 BMT-H.103 Ideal to useforFilling of runways 600ml 470
MAT-05390 /buildings,expansionjoints,constructionj
oints,TerraceCracks,Sealingjointsatdoo
rs, windows, facades, frames,
cracketc.,
Twopart
polysulphidesealant(Gun/PourGrade)
ComplieswithASTM C920-
MAT-05391 95/DIN18549TT -5-00227E/BS 4254 -
371 BMT-H.104 1Kg 410
83
Ideal to useforExpansion
/constructionjointsofrunways,buildingset
c.,
AcrylicLatexCaulkingCompoundC
ompliesASTM-C-834-91
Idealforexteriorandinteriorcrackfillingwor
372 MAT-05392 BMT-H.105 ks, Excellent bonding strength 1Kg 304
toadjoiningsurface.

VII. SUB- PROTECTIVE


SECTION WATERPROOFCOATINGS/C
EMENTBASEDCOATINGS:
Two component sysem High
durablecementitious
acrylicbasedwaterproofingsystems
:Complies withASTMD4541 /BS
MAT-05393
373 BMT-H.106 EN12390/DN1048 1Ltr 134
(2to3 Sqm intwocoats)
For Terrace, Water Tanks,
WallsWaterproofCoatingsofTwoP
artSystem.
374 MAT-05394 BMT-H.107 AcrylicPolymerElastomeric 1Ltr 350

51
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Cementitious
WaterproofCoatingsSurface treatments
for Terrace,
WaterTanks,Walls,ReservoirsWaterproo
fingCoatings.Complies with ASTM
D4541 /BSEN 12390.(Coverage :50to60
SFT
/Ltr/coat)
PUREACRYLICELASTOMERIC
COATINGS
Singlecomponent, High solid,
coldapplied,Acrylicelastomericwaterpro
ofmembrane coatingComplies
withASTMC836/ 89A&ASTMC297
(Coverage:50to60SFTPer/Ltr/Coat)Wh
erever highly flexible,
375 MAT-05395 BMT-H.108 crackBridging,waterproofing required 1Ltr 425
forTerrace, WallsHighly
FlexibleWaterproof Liquid Membrane
pureAcrylicCoatings.
(forbrush/spray
applicationadd20%waterperLtr )
Rubberizedelastomericflexible
waterproofcoating
ComplieswithASTM836/89A&AST
376 MAT-05396 BMT-H.109 MC297 1Ltr 300
Coveage:40 to 50 SFT/ Ltr /
coat(forbrush/spray
applicationadd20%waterperLtr )
BITUMINOUSCOATING
Polyurethane blended
Bituminouswaterproof coating system -
ComplieswithASTMC 836 /D638/DIN-
1048/
ASTMD1004-
MAT-05397 76(Coverage:40to50SFT/Kg/coat)
377 BMT-H.110 1Kg 570
Ideal to useas
waterproofofRCCsubstrates, Roofs,
Sloped roofs,Basements. Provides
jointless andseamless membrane
waterproofing.(forbrush/spray
applicationadd20%waterperLtr )
High Performance Acrylic
blendedBituminouswaterproofcoatingsy
stems.
378 MAT-05398 BMT-H.111 ComplieswithASTMC836 1Kg 350
(Coverage:40to 50 SFT/Ltr/coat)(for
brush / spray applicationadd
20%waterperLtr )
SOLARREFLECTIVECOATING
PureAcrylicSolarReflectiveinsulatorco
ating
379 MAT-05399 BMT-H.112 ComplieswithASTM-G-154: 1Ltr 200
2000&ASTME903/EN1062 -3
requirementof EN 1504/2 :EN1062-
52
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
6
Coverage:15SFT/Ltr/ 3Coats
(forbrush/spray
applicationadd20%waterperLtr
EPOXYCOATINGS
TwocomponentWaterthinnableFoodN
eutral Epoxy coating (Complies
withASTM- C- 881/EN13813)
Coverage:70to 80 SFTperLtr/coatIdeal
MAT-05400 to useas internal coatings
380 BMT-H.113 forpotablewatertanks,reservoirs,sumps 1Kg 425
andwalls.
Part-I1 Kg: Part-II1/2Kgdilutewith
1Ltrofwater

POLYURETHANECOATING
Single component cold
appliedpolyurethane waterproof coating-
Complies withASTM 836 / EN 1062-
381 MAT-05401 BMT-H.114 3requirementofEN1504-2 1Kg 400
Coverage:300GramsPer coat/
Sqm.brush/sprayapplicationadd20%wat
erperLtr
VIII.SUB- ANTICORROSIVEAGENTS
SECTION
Acrylic basedAnti corrosive
coatingToprotecttheexposedreinforce
382 MAT-05402 BMT-H.115 ment/steelstructuresagainstcorrosion. 1Ltr 350
Coverage:40SFTPer Ltr/Coat.

Rustconverter–
rustencapsulatingcoating for steel
MAT-05403 During repairs toprotect, to
383 BMT-H.116 1Ltr 480
convertthe rust
ofreinforcement/steel.
Coverage:50SFTPer Ltr/Coat
Highrangezincrichepoxyresinprimerfor
reinforcement steel
384 MAT-05404 BMT-H.117 protectionagainstcorrosion. 1Kg 475
Coverage:4 Sq.Mtr./Ltr/ Coat

IX. SUB- CURINGCOMPOUND&MISCELLANEOU


SECTION SCHEMICALS

Acrylicblendedwaterbasedconcretecu
ringcompounds
MAT-05405 Complies with ASTM - C - 309 Class-
385 BMT-H.118 ATypes I&II 1Kg 60
Coverage:3.5to 4Sqm/ Kg/ Coat

53
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
CONCRETEREPAIRADMIXTURES
Acrylicpolymermodifiedreinstatementco
ncrete/mortar admixture
Dosage:1to2Ltrs Per Bagof50
KgsCement
MAT-05406
386 BMT-H.119 canbemixedwithrequiredaggregates 1Ltr 450

To achieve trusted High


StrengthConcreting/Structuralrehabilit
ation/concreterepairs.
CRYSTALLIZATIONCOMPOUND
Concrete
waterproofingwithcrystallizationsystem
byblockinginnerpours andcavities of
concrete.
387 MAT-05407 BMT-H.120 Coverage: 1.25 Kg per Sqm / CoatFor 1Kg 360
NegativeWaterPressureTreatmentslik
eCellar/Ceilingareasetc.,

PLUGGINGCOMPOUND
Fastsettingcementbasedpluggingco
mpound. Toarrestwater
flowleakages.
388 MAT-05408 BMT-H.121 1Kg 85
(PowderForm:mixwithwaterdirectap
plication
SHOTCRETE/GUNITING
ADMIXTURE
Set Accelerator for sprayed
concreteand
plasticizerComplieswithIS9103-99/
ASTMC 494TypeC /BS 5075
389 MAT-05409 BMT-H.122 Dosage:1Kgto3KgsperBagof50Kgs 1Kg 85
CementDepend on setting
timerequired
Forshotcrete/Gunniting/
Emergencyconcreteworks
Quick setting,
rapidhardeningandwaterproofing
compound Complieswith ASTM C 494
MAT-05410 TypeC / IS 9103 -99&BS5075.
390 BMT-H.123 Dosage:1Kgto3KgsPerBagof50Kgs 1Ltr 80
Cement Depend on setting timeFor
emergency works/Anti wash
andunderwater concreting.
MICROCONCRETE
Highstrengthnon-
391 MAT-05411 BMT-H.124 1Kg 38
shrinkcementitiousmicroconcrete
TILEADHESIVES /GROUTS

54
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
TileAdhesive.ConfirmstoIS15477-
2004 for both type I& II / BS :
EN12004CTTadhesive.
392 MAT-05412 BMT-H.125 For excellence adhesion, 1Kg 55
improvedworkabilitywaterproofandal
soheatresistanttilefixing adhesive.
At3mmthickness65-70 SFT
Threecomponentsystemepoxygroutfo
r Vitrified tiles, Ceramic
tilesandstones B.S. 5980 : 1980 / BS
393 MAT-05413 BMT-H.126 EN120004, 1Kg 690
R2T.Dependsupontile dimensionand
groutwidth
PolymerModifiedTileGroutComplieswi
thBSEN13888,CG2AW
4-4.5 Sqm/ Kgof150
394 MAT-05414 BMT-H.127 mmx150mmtilesize 1Kg 60
mix1Part
Waterwith4PartsPowderPack
GLASSMATERIALS
I.SECTION (Landingcost–
includingloading,costof conveyance
&unloading)
I.SUB- PLAINGLASSPANES
SECTION
395 MAT-01052 BMT-I.01 PlainFloatGlass4mm thick 1sqm 373
396 MAT-01053 BMT-I.02 PlainFloatGlass5mm thick 1sqm 474
397 PlainFloatGlass6mm thick 1
MAT-01054 BMT-I.03 593
Sqm
398 PlainFloatGlass8mm thick 1
MAT-01055 BMT-I.04 789
Sqm
399 PlainFloatGlass10mmthick 1
MAT-01056 BMT-I.05 830
Sqm
400 PlainFloatGlass12mmthick 1
MAT-01057 BMT-I.06 996
Sqm
II..SUB- PINHEADEDGLASSPANES
SECTION
401 MAT-01064 BMT-I.13 PinheadedGlass4mm thick 1sqm 280
402 MAT-01065 BMT-I.14 PinheadedGlass5mm thick 1sqm 364
III..SUB- TINTEDGLASSPANES
SECTION
403 Tinted-Bronze/GreenGlass4mmthick
MAT-01058 BMT-I.07 1sqm 436

404 Tinted-Bronze/GreenGlass5mmthick
MAT-01059 BMT-I.08 1sqm 545

405 Tinted-Bronze/GreenGlass6mmthick 1
MAT-01060 BMT-I.09 654
Sqm

55
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
406 Tinted-Bronze/GreenGlass8mmthick 1
MAT-01061 BMT-I.10 935
Sqm
407 Tinted-Bronze/GreenGlass10mmthick 1
MAT-01062 BMT-I.11 1090
Sqm
408 Tinted-Bronze/GreenGlass12mmthick 1
MAT-01063 BMT-I.12 1375
Sqm
IV..SUB- FROSTED/GROUNDGLASSPANES
SECTION
409 MAT-01066 BMT-I.15 Frosted/GroundGlass4 mmthick 1sqm 503
410 MAT-01067 BMT-I.16 Frosted/GroundGlass5 mmthick 1sqm 632
V..SUB- TOUGHENEDPANES
SECTION
411 ToughenedPlainGlass5mm(includingGla
MAT-01068 BMT-I.17 1sqm 758
ss)
412 ToughenedPlainGlass6mm(includingGla
MAT-01069 BMT-I.18 1sqm 875
ss)
413 ToughenedPlainGlass8mm(includingGla
MAT-01070 BMT-I.19 1sqm 1167
ss)
414 Toughened Plain Glass 10
MAT-01071 BMT-I.20 1sqm 1399
mm(includingGlass)
415 ToughenedPlainGlass12mm(in
MAT-01072 BMT-I.21 1sqm 1633
cludingGlass)
PAINTS& POLISHES
J.SECTION (Landingcost–
includingloading,costof
conveyance&unloading)
I.SUB- PRIMERS,FILLERS&BASES
SECTION
416 SupplyofwaterbasedCementPrimerofInte
MAT-01073 BMT-J.01 1Kg 141
rior Grade- 1
417 SupplyofwaterbasedCementPrimerof
MAT-01074 BMT-J.02 1Kg 180
ExteriorGrade- 2
418 SupplyofwallputtyofWhiteCementorPoly
MAT-01104 BMT-J.31 20Kg 550
merorCementbased
419 SupplyofRedOxidePrimerPaintforiron 1
MAT-01075 BMT-J.03 121
works ofGrade-1 Litre
420 SupplyofZincChromateYellowOxidePrim
MAT-01076 BMT-J.04 1Litre 175
erpaintforironworks
421 MAT-01077 BMT-J.05 SupplyofWoodPrimer 1Litre 130
422 SupplyofMetalpaste(Putty)forsteelworks
MAT-01078 BMT-J.06 1Kg 130

423 MAT-01079 BMT-J.07 SupplyofPuttyforwood work 1Kg 130


424 MAT-01080 BMT-J.08 SupplyofWhiteLead 1Kg 93

56
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
425 MAT-01081 BMT-J.09 SupplyofSyntheticclearVarnish 1Litre 137
426 MAT-01082 BMT-J.10 SupplyofSpirit 1Litre 96
427 MAT-01083 BMT-J.11 Supplyof LinseedOil 1Litre 55
428 Supplyofthinnerformelaminepolish/frenc
MAT-01084 BMT-J.12 1Litre 131
hpolish
429 SupplyofthinnerforPoly-urethenepolish
MAT-01085 BMT-J.13 1Litre 244

430 MAT-01086 BMT-J.14 SupplyofFrenchPolish 1Litre 179


431 MAT-01087 BMT-J.15 Supplyofready madeWaxPolish 1Kg 514
432 MAT-01091 BMT-J.19 Supplyofwoodadhesivecompound 1Kg 212
433 Supplyofanti-corrosivegrade-1bitumen
MAT-01100 BMT-J.27 1Litre 465
paint ofblackcolour
II.SUB- DISTEMPERPAINTS
SECTION
434 MAT-01092 BMT-J.20 SupplyofDryPowderDistemper 1Kg 40
435 SupplyofacrylicbasedOilBoundwashable
MAT-01093 BMT-J.21 1Kg 81
Distemper
436 Supplyofpaintgradewhitelimeforwash
MAT-01099 BMT-J.26 25Kg 490

437 MAT-01095 BMT-J.23 SupplyofWaterproofCementpaint 1Kg 49


438 SupplyofwaterproofCementpaintpack
MAT-01098 BMT-J.25 25Kg 1009

III.SUB- EMULSIONBASEDPAINTS
SECTION
Supplyofacrylicemulsionpaintinteriorgra
MAT-01097 BMT-J.24 dehavingVOC(VolatileOrganicCompoun 1Litre 168
439
d)contentlessthan50grams/liter.

Supply of acrylic emulsion paint


MAT-01107 BMT-J.34 exteriorgradewithsiliconadditiveshaving 1Lit 194
440
VOC(VolatileOrganicCompound)content
lessthan50grams/liter.
Supplyofacrylicemulsionpaintweatherpr
oofwater-
MAT-01108 BMT-J.35 based,modifiedacrylicwithsiliconadditive 1Lit 214
441
sexteriorgradehavingVOC(VolatileOrga
nicCompound)contentlessthan50grams/l
iter.
IV.SUB- SOLVENTBASED PAINTS
SECTION
Supplyofsyntheticpolymerluxuryplastic
MAT-01094 BMT-J.22 emulsion paint of superior 1Litre 404
442
gradehavingVOC(VolatileOrganicComp
ound)contentlessthan50grams/

57
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
liter.
V.SUB- OILBASED ENAMEL PAINTS
SECTION
Supply of ready mixed Synthetic
MAT-01102 BMT-J.29 EnamelpaintsinallshadesGrade- 1Litre 248
443
IhavingVOC(VolatileOrganicCompound)
content lessthan50grams/liter.
Supply of ready mixed Synthetic
444 MAT-01103 BMT-J.30 Enamelpaints in all shades Grade - II 1Litre 172
havingVOC(VolatileOrganicCompound)c
ontent lessthan50grams/liter.
VI.SUB- TEXTUREPAINTS
SECTION
445 MAT-01105 BMT-J.32 ExteriorTexture. 25Kg 818
446 MAT-01106 BMT-J.33 GoldlineExteriorTexture 25Kg 1060
VII.SUB- SPECIALPAINTS
SECTION
447 MAT-01088 BMT-J.16 SupplyofMelaminePolish 1Litre 314
448 SupplyofInteriorGradePoly-
MAT-01089 BMT-J.17 1Litre 637
UrethenePolish
449 SupplyofExteriorGradePoly-
MAT-01090 BMT-J.18 1Litre 708
UrethenePolish
450 MAT-01101 BMT-J.28 Supplyofgrade-1aluminiumpaint 1Litre 255
Acrylicsprayplasterinpasteform
madewith specially selected inert
mineralfillers, antifungal agents to
MAT-05415 BMT-J.36 protect thematerial the acrylic binding 25Kg 500
451 mediumused gives good surface
adhesion anygrade Spray Plaster-
Superfine(InteriorGrade)
Acrylic coarse spray plaster in
pasteform made with specially selected
MAT-05416 BMT-J.37 inertmineral fillers, antifungal agents 25Kg 400
452
toprotect the material the acrylic
bindingmedium used gives good
surfaceadhesioninteriorgradeAcrylicc
oarse
Supply of acrylic emulsion
MAT-05417 BMT-J.38 paintinteriorpremiumgradehavingV 1Liter 200
453
OC(Volatile Organic Compound)
contentlessthan50grams/liter
Supply ofBase coat as primer
MAT-05418 BMT-J.39 fornaturaltexturesandnaturalstonebased 1Kg 61
454
paints-Exterior GradeBASE COAT
Acrylicsprayplasterinpasteformma
455 MAT-05419 BMT-J.40 de with specially selected 25Kg 1300
inertmineralfillers, antifungalagentsto

58
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
protect the material the acrylic
bindingmedium used gives good
surfaceadhesionexteriorgradeSprayPl
aster(Exterior)
Supply of acrylic emulsion
paintexterior premium grade with
MAT-05420 BMT-J.41 siliconadditiveshavingVOC(VolatileOrg 1Liter 310
456
anicCompound) content less than
50grams/liter.Alltimate
457 MAT-08753 BMT-J.42 Poly-urethane paint 1Liter 500

PARTICLEBOARDS
K (Landingcost–
includingloading,costof
conveyance, unloading)
I.SUB- MELAMINEFACEDPLAINPARTICLEB
SECTION OARDS
458 MelaminefacedSingleDecoPPB-
MAT-01109 BMT-K.01 1Sqm 590
8mmthick
459 MelaminefacedSingleDecoPPB-
MAT-01110 BMT-K.02 1Sqm 670
12mmthick
460 MelaminefacedSingleDecoPPB-
MAT-01111 BMT-K.03 1Sqm 776
18mmthick
461 MelaminefacedSingleDecoPPB-
MAT-01112 BMT-K.04 1Sqm 879
25mmthick
462 MelaminefacedSingleDecoPPB- 1
MAT-01113 BMT-K.05 1463
35mmthick Sqm
463 MelaminefacedTwinDecoPPB-8mmthick 1
MAT-01114 BMT-K.06 679
Sqm
464 MelaminefacedTwinDecoPPB- 1
MAT-01115 BMT-K.07 776
12mmthick Sqm
465 MelaminefacedTwinDecoPPB- 1
MAT-01116 BMT-K.08 898
18mmthick Sqm
466 MelaminefacedTwinDecoPPB- 1
MAT-01117 BMT-K.09 995
25mmthick Sqm
467 MelaminefacedTwinDecoPPB- 1
MAT-01118 BMT-K.10 1869
35mmthick Sqm
II.SUB- INSULATINGPARTICLEBOARDS
SECTION
468 Natural Colour-Insulating Board - 12 1
MAT-01119 BMT-K.11 242
mmthick Sqm
469 Natural Colour-Insulating Board - 18 1
MAT-01120 BMT-K.12 358
mmthick Sqm
470 Natural Colour-Insulating Board - 25 1
MAT-01121 BMT-K.13 414
mmthick Sqm
471 WhiteInsulatingBoard-12mmthick 1
MAT-01122 BMT-K.14 268
Sqm
472 MAT-01123 BMT-K.15 WhiteInsulatingBoard-18mmthick 1 383

59
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Sqm
473 WhiteInsulatingBoard-25mmthick 1
MAT-01124 BMT-K.16 341
Sqm
III.SUB- MEDIUMDENSITYFIBREBOARD
SECTION
MediumFibreBoard:InteriorGrade- 1
474 MAT-01125 BMT-K.17 359
6mmthick Sqm
MediumFibreBoard:InteriorGrade- 1
475 MAT-01126 BMT-K.18 407
8mmthick Sqm
MediumFibreBoard:InteriorGrade- 1
476 MAT-01127 BMT-K.19 545
12mmthick Sqm
MediumFibreBoard:InteriorGrade- 1
477 MAT-01128 BMT-K.20 693
15mmthick Sqm
MediumFibreBoard:InteriorGrade- 1
478 MAT-01129 BMT-K.21 773
18mmthick Sqm
MediumFibreBoard:InteriorGrade- 1
479 MAT-01130 BMT-K.22 1208
25mmthick Sqm
MediumFibreBoard:InteriorGrade- 1
480 MAT-01131 BMT-K.23 1460
30mmthick Sqm
MediumFibreBoard:InteriorGrade- 1
481 MAT-01132 BMT-K.24 1592
35mmthick Sqm
MediumFibreBoard:ExteriorGrade- 1
482 MAT-01133 BMT-K.25 488
6mmthick Sqm.
MediumFibreBoard:ExteriorGrade- 1
483 MAT-01134 BMT-K.26 569
8mmthick Sqm.
MediumFibreBoard:ExteriorGrade- 1
484 MAT-01135 BMT-K.27 753
12mmthick Sqm.
MediumFibreBoard:ExteriorGrade- 1
485 MAT-01136 BMT-K.28 946
15mmthick Sqm.
MediumFibreBoard:ExteriorGrade- 1
486 MAT-01137 BMT-K.29 1059
18mmthick Sqm.
MediumFibreBoard:ExteriorGrade- 1
487 MAT-01138 BMT-K.30 1411
25mmthick Sqm.
MediumFibreBoard:ExteriorGrade- 1
488 MAT-01139 BMT-K.31 1758
30mmthick Sqm.
MediumFibreBoard:ExteriorGrade- 1
489 MAT-01140 BMT-K.32 2077
35mmthick Sqm.
MDFBoard:Plain-Interior- 9mm thick 1
490 MAT-01141 BMT-K.33 346
Sqm
MDFBoard:Plain-Interior- 12mmthick 1
491 MAT-01142 BMT-K.34 393
Sqm
MDFBoard:Plain-Interior- 18mmthick 1
492 MAT-01143 BMT-K.35 487
Sqm

60
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
MDFBoard:Plain-Interior-25mmthick 1
493 MAT-01144 BMT-K.36 584
Sqm
MDFBoard:Plain-Interior- 30mmthick 1
494 MAT-01145 BMT-K.37 890
Sqm
MDFBoard:Plain-Interior- 35mmthick 1
495 MAT-01146 BMT-K.38 1053
Sqm
MDFBoard: Plain-Exterior-9mmthick 1
496 MAT-01147 BMT-K.39 431
Sqm
MDFBoard: Plain-Exterior-12mmthick 1
497 MAT-01148 BMT-K.40 487
Sqm
MDFBoard: Plain-Exterior-18mmthick 1
498 MAT-01149 BMT-K.41 639
Sqm
MDFBoard: Plain-Exterior-25mmthick 1
499 MAT-01150 BMT-K.42 801
Sqm
MDFBoard: Plain-Exterior-30mmthick 1
500 MAT-01151 BMT-K.43 1053
Sqm
MDFBoard: Plain-Exterior-35mmthick 1
501 MAT-01152 BMT-K.44 1213
Sqm
MDFBoard:Interior- 1
502 MAT-01153 BMT-K.45 542
OneSideLaminated-9mm thick Sqm
MDFBoard:Interior- 1
503 MAT-01154 BMT-K.46 613
OneSideLaminated-12mmthick Sqm
MDFBoard:Interior- 1
504 MAT-01155 BMT-K.47 713
OneSideLaminated-18mmthick Sqm
MDFBoard:Interior- 1
505 MAT-01156 BMT-K.48 801
OneSideLaminated-25mmthick Sqm
MDFBoard:Interior- 1
506 MAT-01157 BMT-K.49 1158
OneSideLaminated-30mmthick Sqm
MDFBoard:Interior- 1
507 MAT-01158 BMT-K.50 1235
OneSideLaminated-35mmthick Sqm
MDFBoard:Exterior- 1
508 MAT-01159 BMT-K.51 623
OneSideLaminated-9mm thick Sqm
MDFBoard:Exterior- 1
509 MAT-01160 BMT-K.52 700
OneSideLaminated-12mmthick Sqm
MDFBoard:Exterior- 1
510 MAT-01161 BMT-K.53 793
OneSideLaminated-18mmthick Sqm
MDFBoard:Exterior- 1
511 MAT-01162 BMT-K.54 927
OneSideLaminated-25mmthick Sqm
MDFBoard:Exterior- 1
512 MAT-01163 BMT-K.55 1235
OneSideLaminated-30mmthick Sqm
MDFBoard:Exterior- 1
513 MAT-01164 BMT-K.56 1312
OneSideLaminated-35mmthick Sqm
MDF Board: Interior-Both 1
514 MAT-01165 BMT-K.57 590
SideLaminated-9mm thick Sqm

61
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
MDF Board: Interior-Both SideLaminated- 1
515 MAT-01166 BMT-K.58 700
12mmthick Sqm
MDF Board: Interior-Both SideLaminated- 1
516 MAT-01167 BMT-K.59 801
18mmthick Sqm
MDF Board: Interior-Both SideLaminated- 1
517 MAT-01168 BMT-K.60 1006
25mmthick Sqm
MDF Board: Interior-Both SideLaminated- 1
518 MAT-01169 BMT-K.61 1235
30mmthick Sqm
MDF Board: Interior-Both SideLaminated- 1
519 MAT-01170 BMT-K.62 1312
35mmthick Sqm
MDF Board: exterior-Both SideLaminated- 1
520 MAT-01171 BMT-K.63 666
9mm thick Sqm
MDF Board: exterior-Both SideLaminated- 1
521 MAT-01172 BMT-K.64 792
12mmthick Sqm
MDF Board: exterior-Both SideLaminated- 1
522 MAT-01173 BMT-K.65 937
18mmthick Sqm
MDF Board: exterior-Both SideLaminated- 1
523 MAT-01174 BMT-K.66 1024
25mmthick Sqm
MDF Board: exterior-Both SideLaminated- 1
524 MAT-01175 BMT-K.67 1296
30mmthick Sqm
MDF Board: exterior-Both SideLaminated- 1
525 MAT-01176 BMT-K.68 1390
35mmthick Sqm
IV.SUB- CEMENTBONDEDPARTICLEBOARD
SECTION
Cement bonded particle
526 MAT-01177 BMT-K.69 1sqm 221
boardconformingtoIS14276-6mmthick
Cement bonded particle
527 MAT-01178 BMT-K.70 1sqm 304
boardconformingtois14276-8 mmthick
Cement bonded particle board
528 MAT-01179 BMT-K.71 1sqm 376
conformingtois14276-10mmthick
Cement bonded particle board
529 MAT-01180 BMT-K.72 1sqm 452
conforming to is14276-12mmthick
Cement bonded particle
MAT-01181 BMT-K.73 1sqm 596
530 boardconforming to is14276-
16mmthick
Cement bonded particle 1
531 MAT-05423 BMT-K.109 672
boardconforming to is14276-18mmthick Sqm
Cement bonded particle
532 MAT-01182 BMT-K.74 1sqm 740
boardconforming to is14276-20mmthick
Cement bonded particle
533 MAT-01183 BMT-K.75 1sqm 921
boardconforming to is14276-25mmthick
Cement bonded particle
534 MAT-01184 BMT-K.76 1sqm 1119
boardconforming to is14276-30mmthick
Cement bonded particle
535 MAT-01185 BMT-K.77 1sqm 1495
boardconforming to is14276-40mmthick

62
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Prelaminatedcementbondedparticleboar
536 MAT-01186 BMT-K.78 1sqm 498
d-6 mmthick
Prelaminatedcementbondedparticleboar
537 MAT-01187 BMT-K.79 1sqm 545
d-8 mmthick
Prelaminatedcementbondedparticleboar
538 MAT-01188 BMT-K.80 1sqm 583
d-10mmthick
Prelaminatedcementbondedparticleboar
539 MAT-01189 BMT-K.81 1sqm 671
d-12mmthick
Prelaminatedcementbondedparticleboar
540 MAT-01190 BMT-K.82 1sqm 714
d-16mmthick
CementBondedParticaleDESIGNERBO
MAT-01191 BMT-K.83 ARD Available Designs 1. Lumber 1sqm 260
541 2.Quadra3.MurkStandardsize8’X4’10’X4
’-6mm thick
CementBondedParticaleDESIGNERBO
MAT-01192 BMT-K.84 ARD Available Designs 1. Lumber 1sqm 317
542 2.Quadra3.MurkStandardsize8’X4’10’X4
’-8mm thick
CementBondedParticaleDESIGNERBO
MAT-01193 BMT-K.85 ARD Available Designs 1. Lumber 1sqm 399
543 2.Quadra3.MurkStandardsize8’X4’10’X4
’-10mmthick
CementBondedParticaleDESIGNERBO
MAT-01194 BMT-K.86 ARD Available Designs 1. Lumber 1sqm 480
544 2.Quadra3.MurkStandardsize8’X4’10’X4
’-12mmthick
CementBondedParticaleDESIGNERBO
MAT-01195 BMT-K.87 ARD Available Designs 1. Lumber 1sqm 634
545 2.Quadra3.MurkStandardsize8’X4’10’X4
’-16mmthick
CementBondedBoardconformingtoIS:14 1
546 MAT-01196 BMT-K.88 146
862-2000- 4mmThick Sqm
CementBondedBoardconformingtoIS:14 1
547 MAT-01197 BMT-K.89 209
862-2000- 6mmThick Sqm
CementBondedBoardconformingtoIS:14 1
548 MAT-01198 BMT-K.90 269
862-2000- 8mmThick Sqm
CementBondedBoardconformingtoIS 1
549 MAT-01199 BMT-K.91 309
:14862-2000- 10mmThick Sqm
CementBondedBoardconformingtoIS 1
550 MAT-01200 BMT-K.92 386
:14862-2000- 12mmThick Sqm
CementBondedBoardconformingtoIS 1
551 MAT-01201 BMT-K.93 410
:14862-2000- 14mm Thick Sqm
CementBondedBoardconformingtoIS 1
552 MAT-01202 BMT-K.94 490
:14862-2000- 16mm Thick Sqm
CementBondedBoardconformingtoIS 1
553 MAT-01203 BMT-K.95 529
:14862-2000- 18mm Thick Sqm

63
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
CementBondedBoardconformingtoIS:1 1
554 MAT-01204 BMT-K.96 590
4862-2000- 20mmThick Sqm
MAT-01213 BMT-K.105 ITEMDELETED
555
50 mm thick SOLID WALL
MAT-05421 BMT-K.106 PANELSandwichpanelsmadeoflightwei 1 907
556 ghtFRACC non-asbestos fibre Sqm
reinforcedcementconcrete
75 mm thick SOLID WALL
MAT-05422 BMT-K.107 PANELSandwich panels made of 1 1143
lightweightFRACCnon- Sqm
557
asbestosfibrereinforcedcementconc
rete
Note: Items BMT-K.97 , BMT-K.98,BMT-K.99,BMT-
K.100,BMT-K.101,BMT-K.102,BMT-K.103,BMT-K.104are
removed inthesectionKandarebroughtasnewitemsinthe
Section L as BMT-L.21,BMT-L.22,BMT-L.23,BMT-L.24,BMT-
L.25,BMT-L.26,BMT-L.27,BMT-L.28.
PLYWOOD
L.SECTION (Landingcost–incudingloading,costof
conveyance,unloading)
I.SUB- MOISTURERESISTANT(MR)GRADE
SECTION
3Ply-4mmthickPlywood(IS:303)MRGrade 1
558 MAT-01216 BMT-L.01 363
Sqm
5Ply-6mmthickPlywood(IS:303)MRGrade 1
559 MAT-01217 BMT-L.02 399
Sqm
5Ply-8mmthickPlywood(IS:303)MRGrade 1
560 MAT-01218 BMT-L.03 480
Sqm
5Ply-9mmthick Plywood(IS:303)MRGrade 1
561 MAT-01219 BMT-L.04 480
Sqm
9Ply-12 mmthickPlywood(IS:303)MRGrade 1
562 MAT-01220 BMT-L.05 600
Sqm
9Ply-15 mmthickPlywood(IS:303)MRGrade 1
563 MAT-01221 BMT-L.06 885
Sqm
9Ply-18 mmthickPlywood(IS:303)MRGrade 1
564 MAT-01222 BMT-L.07 867
Sqm
II.SUB- BOILINGWATERRESISTANT(BWR)GR
SECTION ADE
3Ply- 1
565 MAT-01223 BMT-L.08 423
4mmthickPlywood(IS:303)BWR/BWP Sqm
Grade
5Ply- 1
566 MAT-01224 BMT-L.09 472
6mmthickPlywood(IS:303)BWR/BWP Sqm
Grade
5Ply- 1
567 MAT-01225 BMT-L.10 588
8mmthickPlywood(IS:303)BWR/BWP Sqm
Grade
5Ply- 1
568 MAT-01226 BMT-L.11 554
9mmthickPlywood(IS:303)BWR/BWP Sqm
Grade
64
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
9Ply- 1
MAT-01227 BMT-L.12 725
569 12mmthickPlywood(IS:303)BWR/BWP Sqm
Grade
9Ply- 1
MAT-01228 BMT-L.13 1031
570 15mmthickPlywood(IS:303)BWR/BWP Sqm
Grade
9Ply- 1
MAT-01229 BMT-L.14 1044
571 19mmthickPlywood(IS:303)BWR/BWP Sqm
Grade
III.SUB- VENEEREDDECORATIVEPLYWOOD
SECTION
3Ply- 1
MAT-01230 BMT-L.15 561
572 4mmthickOnesideTeakVeneerDecoratedPly Sqm
wood(IS:1328)
5 Ply - 6 mm thick One side 1
573 MAT-01231 BMT-L.16 731
TeakVeneerDecoratedPlywood(IS:1328) Sqm
5 Ply - 9 mm thick One side 1
574 MAT-01232 BMT-L.17 894
TeakVeneerDecoratedPlywood(IS:1328) Sqm
9 Ply - 13 mm thick One side 1
575 MAT-01233 BMT-L.18 1193
TeakVeneerDecoratedPlywood(IS:1328) Sqm
5 Ply - 9 mm thick Both sides 1
576 MAT-01234 BMT-L.19 1221
TeakVeneerDecoratedPlywood(IS:1328) Sqm
9 Ply - 12 mm thick Both sides 1
577 MAT-01235 BMT-L.20 1359
TeakVeneerDecoratedPlywood(IS:1328) Sqm
IV.SUB- LAMINATES
SECTION
LaminateSheets-GlossyFinish:1mmthick 1
578 MAT-01205 BMT-L.21 367
Sqm
LaminateSheets- 1
579 MAT-01206 BMT-L.22 524
GlossyFinish:1.50mmthick Sqm
LaminateSheets- 1
580 MAT-01207 BMT-L.23 575
GlossyFinish:1.80mmthick Sqm
LaminateSheets-MatFinish:1mmthick 1
581 MAT-01208 BMT-L.24 370
Sqm
LaminateSheets-MatFinish:1.50mmthick 1
582 MAT-01209 BMT-L.25 516
Sqm
LaminateSheets-MatFinish:1.80mmthick 1
583 MAT-01210 BMT-L.26 555
Sqm
V.SUB-
SECTION COMMERCIALVENEERS

TeakVeneerLamination-4mmthick- 1
584 MAT-08743 BMT-L.27 410
PencilGrains Sqm
TeakVeneerLamination-4mmthick- 1
585 MAT-08744 BMT-L.28 717
NaturalGrains Sqm
ProvidingWood Polymer
BMT-L.29 Composite(WPC)solid,frostywhitesingleextr
udedfactory made2.44 mt x 1.22 mt
boardsin

65
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
6MMthickness(Density550kg/Cum,W
586 MAT-05424 BMT-L.29.A sqmt 630
eight9.5Kg)
11MMthickness(Density500kg/Cum,W
587 MAT-05425 BMT-L.29.B sqmt 1080
eight16.5Kg)
18MMthickness(Density650kg/Cum,W
588 MAT-05426 BMT-L.29.C sqmt 2145
eight35Kg)
CEILINGS,WALLPARTITIONS&
M.SECTION
WALLLININGS
I.SUB- FALSECEILINGs-TILES/ SHEETS
SECTION
GypsumBoardtilesofsize notlessthan
MAT-01236 BMT-M.01 1 238
589 0.595Mx0.595M of12.5
Sqm
mmthickasperIS 2095-1992
GypsumBoardtilesofsize notlessthan
MAT-01237 BMT-M.02 1 232
590 0.595Mx0.595M of9 mm
Sqm
thickasperIS2095 -1992
GypsumBoardPlainsheet12.5mmthickas 1
591 MAT-01238 BMT-M.03 210
per IS 2095-1993 Sqm
14 mm -Mineral Fiber sheet 600 x
600ofBoard/TegularEdgetileswithaHumi
dityResistanceof80%RH,AverageNRC0. 1
MAT-01263 BMT-M.28 50,LightReflectance Sqm 524
592
>80%, Thermal Conductivity λ = 0.052to
0.057 w/mk, Fire Performance
Class0/Class1
15 mm -Mineral Fiber sheet 600 x
600ofBoard/TegularEdgetileswithaHumi
dityResistanceof90%RH,AverageNRC0. 1
MAT-01264 BMT-M.29 50,LightReflectance Sqm 614
593
>80%, Thermal Conductivity λ = 0.052to
0.057 w/mk, Fire Performance
Class0/Class1
16 mm -Tegular Edge 600 x 600
ofBoard / Tegular/ Micro look Edge
tileswith a Humidity Resistance of 99% 1
MAT-01265 BMT-M.30 RH,AverageNRC0.60,LightReflectance Sqm 661
594
>88%, Thermal Conductivity λ = 0.052to
0.057 w/mk, Fire Performance
Class0/Class1
12mm- 1
MAT-01266 BMT-M.31 406
595 MineralFibersheet600x600(Square/Tegul Sqm
ar) Edgetiles
SupplyofThermocole 1
MAT-01271 BMT-M.36 24
596 12mmthicks Sqm
heets
SupplyofThermocole 1
MAT-01272 BMT-M.37 41
597 19mmthicks Sqm
heets
CalciumSilicateBoards -6mmthick 1
598 MAT-01275 BMT-M.40 198
Sqm

66
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
CalciumSilicateBoards -8mmthick 1
599 MAT-01276 BMT-M.41 263
Sqm
CalciumSilicateBoards -10mmthick 1
600 MAT-01277 BMT-M.42 330
Sqm
CalciumSilicateBoards -12mm thick 1
601 MAT-01278 BMT-M.43 395
Sqm
SupplyingandfixingoffalseceilingusingPl
asterofparisBoards12mmthickwithstand
MAT-01286 BMT-M.51 ardGIceilingangles,sectionsperimeterch 1 405
602 annelsincludingcostandconveyanceofall Sqm
materialsand labourchargesetccomplete

SupplyingandfixingoffalseceilingusingPl
asterofparisBoards10mmthickwithstand
MAT-01287 BMT-M.52 ardGIceilingangles,sectionsperimeterch 1 338
603 annelsincludingcostandconveyanceofall Sqm
materialsand labourchargesetccomplete

Designer ceiling Cement Boards - 1


604 MAT-01288 BMT-M.53 212
thickness3.2mm Sqm
HighpressuresteamcuredCementBoards4 1
605 MAT-01289 BMT-M.54 113
mmthick Sqm.
HighpressuresteamcuredCementBoards6 1
606 MAT-01290 BMT-M.55 170
mmthick Sqm.
HighpressuresteamcuredCementBoards8 1
607 MAT-01291 BMT-M.56 225
mmthick Sqm.
HighpressuresteamcuredCementBoards1 1
608 MAT-01292 BMT-M.57 283
0 mmthick Sqm.
HighpressuresteamcuredCementBoards1 1
609 MAT-01293 BMT-M.58 339
2 mmthick Sqm.
HighpressuresteamcuredCementBoards1 1
610 MAT-01294 BMT-M.59 395
4 mmthick Sqm.
HighpressuresteamcuredCementBoards1 1
611 MAT-01295 BMT-M.60 452
6 mmthick Sqm.
HighpressuresteamcuredCementBoards1 1
612 MAT-01296 BMT-M.61 508
8mmthick Sqm.
HighpressuresteamcuredCementBoards2 1
613 MAT-01297 BMT-M.62 564
0 mmthick Sqm.
HighpressuresteamcureddesignerCemen 1
614 MAT-01298 BMT-M.63 166
t Boards4mmthick Sqm.
HighpressuresteamcureddesignerCemen 1 245
615 MAT-01299 BMT-M.64
t Boards6mmthick Sqm.
SupplyandfixingofCEMENTBONDEDPA
MAT-01305 BMT-M.70 RTICLEBOARDS(IS14276)false 1 924
616 ceilingusing8MMCEMENTBONDEDPAR Sqm
TICLEBOARDSwithgalvanized

67
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
and pre painted steel T section of
size24mm x 38mm x 0.3 mm for main T
dutyprepunchedtoacceptcrossTsectionof
size 24mm x 30mm x 0.3 mm
dulypunched at both ends for insertion
intomain T. The grid size will be 610mm
x610mm.Theframework(grid)issuspende
d to the roof byusing G.I
flatof0.60mmor14-
gaugeG.Iwirewithnecessary fixers to the
roof and
framework.CEMENTBONDEDPARTICL
E
BOARDSlayonthegrid.Thecostinclusive
of necessary hardware, labor,one coat
of primer (Both side) and
twocoatsofsmoothfinish onvisibleside.
Providingandfixingfalseceilingconsisting
of600mmX600mm,SolidPVCinsulationp
anelshavingwallthickness of 1mm thick
plain PVC rigidfoam sheet and EPS as
defined in
ofdesiredthicknessdependingoninsulatio
n required shall be insert in
aframeworkmadeusinganodizedaluminiu
mTeesectionofsizes1”X1”(25X25mm, 19
MAT-01314 BMT-M.79 gauge or 1mm thick) 1sqm 1179
insquarepatternofgridsizesof2’X2’(600X
617 600mm).Thealuminiumframework is
supported from the
ceilingwiththehelpofG.I.hookandG.I.wire/
6mm.M.S. rods of required sizes
tomaintain proper level etc. the
aluminiumframework is supported on
side wall withthe use of aluminium 1”X1”
(25X25mm)angles,completeasperdirecti
onofEngineer-in-
Charge,manufacture’sspecification&
drawing
MineralFibreCeilingTileof0.595mmx
MAT-01315 BMT-M.80 1 321
618 0.595mmof 13mmthickSquare Edge-
Sqm
FissuraFineModel
MineralFibreCeilingTileof0.595mmx
MAT-01316 BMT-M.81 1 359
619 0.595mmof 13mmthickSquare Edge-
Sqm
SpeckleModel
MineralFibreCeilingTileof0.595mmx
MAT-01317 BMT-M.82 1 397
620 0.595mmof 13mmthickSquare Edge-
Sqm
TexturaModel
MineralFibreCeilingTileof0.595mmx
MAT-01318 BMT-M.83 1 406
621 0.595mmof15mmthickStandardRegular
Sqm
Edge
Mineral FibreCeilingTile of0.595 mmx
MAT-01319 BMT-M.84 1 416
622 0.595mmof15mmthickFissuraFineMod
Sqm
el

68
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Mineral FibreCeilingTile of0.595 mmx
MAT-01320 BMT-M.85 1 434
623 0.595mmof15mmthickSpeckleModel
Sqm

MineralFibreCeilingTileof0.595mmx
MAT-01321 BMT-M.86 1 471
624 0.595mmof15mmthickTexturaModel
Sqm

Supply and fixing of PVC false


ceilingonMS/GImadeskeletonframewor
k.The frame shall be 24 X 48mm MS
tubesection fixed along with the
wall.Theentireframeworkshallbeconceal 1
MAT-01322 BMT-M.87 edwithPVCsectionhavingoveralldimensi Sqm. 1308
625 ons of 6 X 250mm with a wallthickness
of 1mm ± 0.3mm with
tongueandgroovesystem,providedwithne
cessaryarrangementsforelectricalconnec
tions, complete, for finished itemofwork.

Absorptive false ceiling


Supply and installation of 12.5mm thick
micro perforated gypsum plaster board
of 3mm square perforations (minimum
13% of perforated area) backed with
50mm thick 1000 GSM polyester wool
Construction of Frame work:
Frame work shall consists of GI
perimeter channels of size 0.55mm thick
(having one flange of 20mm and
another flange of 30mm) fixed along
with perimeter of the beam or walls with
the help of nylon sleeves and screws at
600mm c/c. Then suspend GI main
channels of size 45 mm (0.9mm thick
with 2 flanges of 15mm each) from the
1
626 MAT-08745 BMT-M.96 soffit at 1200mm c/c by using soffit 2250
Sqm.
angle of size 25mm x 10mm x 0.55mm
thick fixed to true ceiling by using
suitable fasteners. Cross channels of
size 0.55mm thickness having knurled
web of 51.5mm and two flanges of
26mm each with lips of 10.5mm are
then fixed to the main channel with the
help of connecting clips and in a
direction perpendicular to the main
channel at 300mm c/c
Cavity Filling:
Ceiling frame work shall be back lined
by using polyester wool having density
of 1000 GSM and 50mm thick
Boarding:

69
BasicRat
e forSoR
S.No CFMScode ItemCode Descriptionofitem Unit 2021-
22 (Rs.)
1 2 3
4 5

A layer of 12.5mm thickness fiber


reinforced micro perforated gypsum
plaster board of size 1200 x 2400 mm
having perforations of minimum of 13%
is fixed on to frame work. Micro
perforated gypsum boards used shall
have RH 90% and fire rating A2-s1, d0
Finishing: Ensure that board is fixed in
plumb level, screw fix gypsum plaster
board to channel, cover screw with
compound and sand the surface. Joints
of gypsum plaster board to be finished
by using jointing tapes and compound.
Final finishing is done with two coats of
acrylic emulsion paint.

Reflective false ceiling


Supply and installation of 12.5mm thick
plain gypsum plaster board
Construction of Frame work:
Frame work shall consists of GI
perimeter channels of size 0.55mm thick
(having one flange of 20mm and
another flange of 30mm) fixed along
with perimeter of the beam or walls with
the help of nylon sleeves and screws at
600mm c/c. Then suspend GI main
channels of size 45 mm (0.9mm thick
with 2 flanges of 15mm each) from the
soffit at 1200mm c/c by using soffit
angle of size 25mm x 10mm x 0.55mm
thick fixed to true ceiling by using
suitable fasteners. Cross channels of
size 0.55mm thickness having knurled
1
627 MAT-08746 BMT-M.97 web of 51.5mm and two flanges of 3170
26mm each with lips of 10.5mm are Sqm
then fixed to the main channel with the
help of connecting clips and in a
direction perpendicular to the main
channel at 300mm c/c.
Boarding:
A layer of 12.5mm thickness Plain
gypsum plaster board of size 1200 x
2400mm having minimum density
550kg/m3 is fixed on to frame work.
Finishing:
Ensure board is in plumb level, screw fix
gypsum plaster board to channel, cover
screw with compound and sand the
surface. Joints of gypsum plaster board
to be finished by using jointing tapes
and compound. Final finishing is done
with two coats of acrylic emulsion paint.

70
BasicRat
e forSoR
S.No CFMScode ItemCode Descriptionofitem Unit 2021-
22 (Rs.)

1 2 3 4 5

II.SUB- FALSECEILINGs-
SECTION SECTIONS&ACCESSORIES

G.I.CeilingAngle-25mmx10mmx
MAT-01239 BMT-M.04 1RM 69
628 0.55mm

G.I.CeilingSection51.5mmx26mmx
629 MAT-01240 BMT-M.05 1RM 79
10.5mmx 0.55 mmthick

G.I.IntermediateSection45mmx15mmx
MAT-01241 BMT-M.06 1RM 78
630 15mmx 0.9 mm

G.I.PerimeterChannel-
MAT-01242 BMT-M.07 1RM 69
20mmx27mmx30mm(web) of0.55
631
mmthick

G.I.-
MAT-01243 BMT-M.08 1RM 38
PrecoatedFinelineGrid25mmx25mmx
632
0.7mm

G.I.-
MAT-01244 BMT-M.09 1RM 34
PrecoatedFinelineGrid15mmx25mmx
633
0.7mm

GI -Precoated -T-Sec-24mm
MAT-01245 BMT-M.10 1RM 50
634 x38mmx0.7mmthick

HotdippedGIAngle-Precoated-
MAT-01246 BMT-M.11 1RM 37
635 Grid:19mmx 19mm

PolyesterpaintedGI-TSection-24x32mm
636 MAT-01247 BMT-M.12 1RM 46

PolyesterpaintedGI-TSection-24x25mm
637 MAT-01248 BMT-M.13 1RM 41

PolyesterpaintedGI-TSection-24mmx
MAT-01249 BMT-M.14 1RM 42
638 27mm

MAT-01250 BMT-M.15 AluminiumAngle:24mmx24mm 1RM 26


639

AnodisedAluminiumTSection:24x
640 MAT-01251 BMT-M.16 1RM 31
24.5x2.4 mm

MAT-01252 BMT-M.17 ConnectingClips 1 3


641
Each

71
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
RawlPlug 1
642 MAT-01253 BMT-M.18 2
Each
6mm NylonRawlPlug 1
643 MAT-01254 BMT-M.19 4
Each
SoffitCleats 1
644 MAT-01255 BMT-M.20 3
Each
DrywallScrews -25 mm 1
645 MAT-01256 BMT-M.21 2
Each
646 MAT-01257 BMT-M.22 JointingCompound 1Kg 27
647 MAT-01258 BMT-M.23 JointingPaperTape 1RM 4
648 MAT-01259 BMT-M.24 DrywallTopCoat 1Litre 130
UniversalHoldingClips 1
649 MAT-01260 BMT-M.25 3
Each
MAT-01261 BMT-M.26 4mm DiaGIConnecting Rod 1RM 12
650

MAT-01262 BMT-M.27 2mm DiaGIConnecting Rod 1RM 8


651

III.SUB- WALLPANELLS&WALL LININGS


SECTION
Providing wooden panelling 12 mm
thickonesidelaminatedsheetfixedonwood
en frame of BT wood size 50.8
mmx25.4mm(2"x1")atdistanceof609.6m 1
MAT-01274 BMT-M.39 Sqm 1405
m (2'-0") intervals of both waysproviding
652 3/4" x 1/2" (19.05 mm x
12.7mm)sizeBTwoodornamentalcoverbe
ading and necessary screws,
fevicolgluecompleteforfinisheditemof
work.

Perforated wall panels channeled


woodworkssheetsofwidth128mm,thickne
ss of 16mm and length 2440 mmmade
of a high density particle boardsubstrate
with a laminatedfacing
aspertheapprovedshade/Species&Finish
and a melamine balancing 1
MAT-01267 BMT-M.32 Sqm 2318
layeronthereverseside,withaspecialperfo
653
ration pattern fluted perforation onthe
visible surface with a minimum
sagresistanceofRH90andafireratingclass
of 1 as per Part 7 of BS 476 with
a“tongue-and-
grooved”edgesandthebackoftheperforat
edpaneliswithsound absorbing non-
woven acousticalfleece
Supplyandfixingofwallpanelling(water,fir
MAT-01300 BMT-M.65 eandTermiteproof)withframe work made 1 816
654 Sqm.
of GI stud profile
ofsize48x40x10x0.6mmthickplaced

72
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
atevery610mmC/Cintervalsfixedverticall
y in between floor and roof `U’track of
size 50 x 30 x 0.6 mm thick
dulyfixedwithselfexpansionscrewsandwit
h 8 mm thick E-board / 6 mm thick E-
board classic cladded around with
selftapping self embedding screws fixed
atevery 300 mm (centres) leaving a 3
mmgap between two panels of width 2’-
0”.TheGapwillbecoveredwithadecorative
beading.Surfacewillbegivenasmoothfinis
hoveracoatofprimer. - With 8 mm
Designer CEMEMTBONDEDBOARD

655 MAT-01301 BMT-M.66 ITEMDELETED


SupplyandfixingCEMENTBONDEDPAR
TICLE BOARDS(IS 14276) wall
panelingusing10MMCEMENTBONDED
PARTICLE BOARDS with
frame work made of GI stud section
ofsize48mmx35mmx0.55mmthickplaced
at every 610 mm C/C
intervalsverticallyandat1200mminternals
MAT-01306 BMT-M.71 horizontally fixed to the wall by means 1 1161
ofselfexpansionscrewsandcaps.CEMEN Sqm
656
T BONDED PARTICLE
BOARDSistobefixedtoframebymeans of
self taping screws placed
atevery300mmintervalsleaving3mmgapb
etweentwopanels.Thecostinclusive of
one coat o primer and
twocoatsofsmoothfinishandcost&convey
anceofallmaterials,laborchargesetc.com
pleteasperthedirection ofEngineerin
charge.
Supply and fixing of CEMENT
BONDEDPRE-
LAMINATEDPARTICLEBOARDS
wallpanelingusing12MMCEMENTBOND
EDPRE-LAMINATEDPARTICLE
BOARDS with frame work made of
G.Istud sectionof size 48mm x 35mm
MAT-01309 BMT-M.74 1 1763
x0.55mm thickplacedat
Sqm
every610mmintervalsverticallyandat120
657 0mminternals horizontally fixed to the
wall
bymeansofselfexpansionscrewsandcaps
.LAM is to be fixed to frame bymeans of
self-taping screws placed atevery
300mm intervals leaving 3mm
gapbetween two panels. The cost
inclusiveofConveyanceofmaterials,Labor
chargesetc.,completeasperthedirection
ofEngineerincharge
658 MAT-01312 BMT-M.77 ProvidingandfixingINSULATEDPVC 1Sqm 1696

73
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
WALL PANELING shall consist of
PVCinsulated panelshaving
wallthicknessof1mm/1.5mm/2mmPVCsh
eetandthedesiredthicknessofEPS(depen
dent on theinsulation required)screwed
into the wall using
screwsofadequatelength.Thescrewsshal
lbeplaced at a distance of 150mm and
shallbe 25mm from the edge of the
insulatedpanel on all from sides of the
panel. ThePVC strips of 5mm thick PVC
sheet
ofwidth75mmfeatheredattheedgesshallb
estuckusingsolventcementadhesiveatthe
placeswheretwopanelsarejoined,soatoc
overthescrew of both the panels, using
solventcement.90heatbentstripsof5mmt
hickPVCsheetsofwidth75mmX75mm
feathered at the edges shall
bestuckatwalljoints/pillarsetc.,complete
as per direction of Engineer-in-Charge,
manufacture’s specification &drawing

ProvidingandfixingplainPVCrigidfoam
sheet wall panelling of
thickness5mmconsistingofpanelshaving
size1220mmX2440mmstuckoninnerfram
e work of 25mm wide strips of 5mmthick
PVC rigid foam sheet. The stripsshould
have in their centre a grove of6mm
width and 2mm depth for sinkingthe
head of the screw used to fix thestrips to
the wall and should be
placedverticallyatequalintervalsof405/40
7mm centre to c entre. The
PVCstripsshallbefixedtothewallusing65m
659 MAT-01313 BMT-M.78 mlongM.S.screwsthroughthegrooveinthe 1Sqm 1612
stripbyusingPVCfasteners.Thedistanceb
etweentwoscrewsshallnotbemorethan30
0mm.a groove of 2mm may be left at the
jointof two panels for aesthetic looks.
Thisframework is done for making
existingwallsurfaceinensuredlevelandfor
sticking the wall panelling sheet
(panel)on it. The exact size of the panel
andcorrespondinglyofthegridMaybevarie
d depending n the size of the
wall.However it must be ensured that a
stripsof 5mm thick PVC sheet of width
75mmfeathered at the edges shall be
stuck atthe places where two panels are
joined,using solvent cement. , complete
as perdirectionofEngineer-in-Charge,

74
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
manufacture’sspecification&drawing
Supply andfixingof
wallpanellingontheframeworkofwoodedri
ppersof24X 24mm of required size.The
entireframework shall be panelled with
660 MAT-01323 BMT-M.88 PVCsection having overall dimensions 1 1239
of 6 X250mm with a wall thickness of Sqm.
1mm
±0.3mm.Thepanelsarejoinedwithtongue
and groove system.Necessarycut-outs
for electrical connections to
beprovidedatrequiredplacescomplete,for
finisheditemofwork.
Supply and fixing of wall lining fixing
toGI channels of perimeter channel
30mmx27mmx0.55thickandceilingchann
elsof51.1mmx26mmx10.5mmx 0.55mm
thick and fixing and
finishingusingjointcompoundandglassfibr
etape complete finish as per
specificationwithoutpaintingforfinishedite
mofwork:
A)using8mmthickCalciumsilicateboar 1
661 MAT-01282 BMT-M.47 702
ds Sqm
B)Using10mmthickCalciumsilicatebo 1
662 MAT-01283 BMT-M.48 773
ards Sqm
C)Using12mmthickCalciumsilicatebo 1
663 MAT-01284 BMT-M.49 844
ards Sqm
Providing andfixing in
positionwallpanelling to all heights with
eco friendlylight weight calcium silicate
panels/tilesGlobe Design of size 595mm
x 595mmhaving square/butt edge
havingNRC(NoiseReductionCoefficient)
of0.5to 0.75 as per IS 8225:1987,
Lightreflectance of 85%(minimum),
NonCombustible as per BS:476 (part-4),
fireperformance as per BS:476 (part-
6&7),humidityresistanceof100%andther 1 2155
mal conductivity < 0.043 W/m K asper Sqm
MAT-05430 ASTM 518:1991, comprising of aframe
664 BMT-M.95
made from especially
fabricatedgalvanised mild steel
sheet0.50 mmthick pressed section
(galvanizing @120grams per sqm
including both
sides)i.e.verticalstudsofsize48x34x36m
m are placed at 600mm center tocenter
in a floor and
ceilingchannelsectionofsize50x32mfixed
tothefloor and soffit at 600mm centers
using12mm dia,50mm long wedge
typeexpanded zinc alloy dash fastner
with10mmbolt.Glasswoolof50mm

75
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
thickness is then to be inserted in
theslots and finallycalcium silicate
noncombustiblepanels/tilesaretobescre
wfixed with self tapping pan head
nickelcoated mild steel screws of size
13 x3.2mm on to this grid leaving an
evengrooveof1 mmbetween thepanels.
The joints between the panels are to
beduly jointed and finished
usingrecommended jointing calcium
silicatebased compound & fiber joint
tape roll50mm wide (90 metre )roll and
twocoats of primer suitable for panelling
aspermanufacturer'sspecificationasperd
irection of Engineer-in-Charge
allcomplete.(With 15 mm thick
integraldensified fully perforated light
weightcalcium silicatepanels/tiles)
Wall-Absorptive wall panelling
Supply and installation of 17mm thick
micro perforated wood having 2mm
perforation and 8mm pitch backed with
polyester wool of density 1000GSM x
50mm thick with Laminared finish
Construction of Frame work:
Frame work consists of 25mm thick GI
wall channels with fully knurled surface
of 0.55mm thick 80mm width, having
two equal flanges of 26mm. A GI wall
channel is fixed to the walls in
horizontal direction with the help of
suitable fastners at 600mm c/c then
another 25mm thick GI wall channel is
fixed vertically over the horizontally laid
wall channel at 600mm c/c
665 BMT-M.98 Cavity Filling:
MAT-08747
The frame work shall be back lined by 1
using polyester wool having a density of Sqm 4580
1000 GSM and 50mm thick
Boarding:
17mm thick micro perforated wood
having 2mm perforation and 8mm pitch
is fixed on the frame work.
Finishing:
Ensure board is in plumb level and
screw heads to be covered with
compound and sand the surface. The
screws are painted with manufacturer
supplied paint matching the colour of
the board/panel. The finishing of board
is of veneer finish.

76
BasicRat
S.No CFMScode ItemCode Unit e forSoR
Descriptionofitem
2021-
22 (Rs.)
1 2 3 4 5
Wall-Reflective wall panelling
Supply and installation of 12 mm thick
B.W.P ply finished with 1 mm thick
laminate on all visible sides backed with
50mm thick 1000 GSM polyester wool
insulation
Construction of Frame work:
Frame work consists of minimum 50mm
GI stud with fully knurled surface of
0.55 mm thick, 50mm width and two
equal flanges of 34mm is fixed on to the
GI support made of required height,
First the wall plate is fixed on to the wall
using suitable fastners at every
1200mm C/C in both the directions and
an MS hollow box section of
40mmx40mm with 5mm thick is welded
to the wall plate, this is used to give the
support to the MS gride of
600mmx600mm which is placed at a
666 MAT-08748 BMT-M.99 distance of 480mm from the wall. 1
Cavity Filling: Sqm 880
The frame work shall be back lined by
using polyester fiber having a density of
1000 GSM and 50mm thick held in
position by using GI weld mesh
Boarding:
12mm thick Laminared plywood (8mm
plywood and 1mm laminate) of
approved finish is then fixed to GI frame
work by using suitable fasteners and
ensure proper level of the panel
surface.
Finishing:
Ensure plywood is in plumb level and
finish by using laminate of approved
shade and colour

IV PARTITIONS
Supply & fixing 75mm thick metal
studpartition using 12.5 mm thick
Gypboardconforming to IS 2095-1982
667 screw fixedto eitherside to 48 1
MAT-01273 BMT-M.38 Sqm 1090
mmstudsof
0.55mmthickwiththe50mmfloorandceilin
g channel 0.55 mm and the jointsduly
finished with joint compound, papertape
and two coats Dry wall top coat
asperspecification.

77
BasicRat
S.No CFMScode ItemCode Unit e forSoR
Descriptionofitem
2021-
22 (Rs.)

1 2 3 4 5

Supply and Fixing 66mm thick


metalstud partition screw fixed to either
sideof 48mm studs of 0.55mm thick
with50mmfloorandceilingchannel0.55m
MAT-01279 BMT-M.44 1 1230
mand the joints duly finished with
Sqm
668 joiningcompound, glass fibre tape and
twocoats dry wall top coat as
perspecification finishedItem of work-
using 8mm thick Calcium
silicateboards

Supply and Fixing 66mm thick


metalstud partition screw fixed to either
sideof 48mm studs of 0.55mm thick
with50mmfloorandceilingchannel0.55m
MAT-01280 BMT-M.45 1 1380
mand the joints duly finished with
669 Sqm
joiningcompound, glass fibre tape and
twocoats dry wall top coat as
perspecification finishedItem of work -
Using 10mm thick Calcium
silicateboards
Supply and Fixing 66mm thick
metalstud partition screw fixed to either
sideof 48mm studs of 0.55mm thick
with50mmfloorandceilingchannel0.55m
m
670 andthejointsdulyfinishedwithjoiningcom 1
MAT-01281 BMT-M.46 1530
pound, glass fibre tape and twocoats Sqm
dry wall top coat as perspecification
finishedItem of work -Using 12mm thick
Calcium silicateboards

SupplyandFixing66mmthickmetalstudpar
titionusing2layersof12mmthick Calcium
silicate boards screw fixedto either side
to 48mm studs of
0.55mmthickwith50mmfloorandceilingch
annel 0.55mm.Theboards 1
MAT-01285 BMT-M.50 jointsaretobestaggeredtoavoidthroughpa Sqm 3900
ssage. Ceramic wool of 50mm
671 thick,64kg/m3 density is to be placed in
cavityof the partition. The joints duly
finishedwith joining compound, glass
fibre tapeand twocoats dry wall top coat
as
perspecificationwithoutpaintingforfinishe
d itemofwork

78
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
SupplyandFixing66mmthickmetalstudpar
titionusing2layersof12mmthick Calcium
silicate boards screw fixedto either side
to 48mm studs of
0.55mmthickwith50mmfloorandceilingch
annel 0.55mm.Theboards 1
672 MAT-01285 BMT-M.50 jointsaretobestaggeredtoavoidthroughpa Sqm 3900
ssage. Ceramic wool of 50mm
thick,64kg/m3 density is to be placed in
cavityof the partition. The joints duly
finishedwith joining compound, glass
fibre tapeand twocoats dry wall top coat
as
perspecificationwithoutpaintingforfinishe
d itemofwork

Supply and fixing double skin


CEMENTBOARD partition with Frame
work
madeofGIstudprofileofsize48x40x10x
0.6 mm thick placed at every 610
mmC/Cintervalsand915mmhorizontalint
ervals duly fixed with self
673 MAT-01302 BMT-M.67 1 1240
expansionscrews,theE-
Sqm.
boardof8mmthickcladdedaroundwithselft
appingselfembeddingscrewsfixedatever
y300mm(centres)leaving3mmgapbetwe
en two panels of width 2’-0”
(610mm).Thegapwillbecoveredwithdecor
ativemouldingsurfacewillbegivenasmoot
hfinishovercementprimer. The rate is
inclusive of cost andconveyance of all
materials and
labourchargesetc.complete.

Providingandfixingof50mmthickSOLID
WALL PANEL Sandwich panelsmade of
light Weight FRACC two 4mmthicknon-
asbestosfibrereinforcedcementsheetson
eithersideofthelightweight concrete core
composed
674 ofPortlandcementbinderswithtongueand
MAT-01303 BMT-M.68 1sqm 1540
groove arrangement. The bottom
ofthepanelshallbefixedtothefloorchannel
madeupof1mmthickGIchannels of size
14x50x25 mm fixed tothe existing floor
with 6x60mm nylon selfexpansion
screws at 600 mm C/C
andtopofthepanelfixedwithceilingchannel
madeoutof1mmthickGIChannelofsize38
x50x38mmdulyfixed

79
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
totheexistingceilingwith6x60mmnylon
self expansion screws at 600 mmC/C.
All the tongue and groove joints ofthe
panels have to be properly cleanedand
both the panels have to be fixed
byapplyingthemixtureofflyashandsodium
silicate in between and
Everestjointingcompoundalltheexposedj
oints. The rate includes cost of
50mmSOLIDWALLPANELS,G.l.Flooran
d
ceilingchannel.Thepanelscanbeflushed
by using paper tape and
Everestjointingcompound allcomplete

Providingandfixingof75mmthickSOLID
WALL PANEL Sandwich panelsmade of
light Weight FRACC two 4mmthicknon-
asbestosfibrereinforcedcementsheetson
eithersideofthelightweight concrete core
composed
ofPortlandcementbinderswithtongueand
groove arrangement. The bottom
ofthepanelshallbefixedtothefloorchannel
madeupof1mmthickGIchannels of size
14x75x25 mm fixed tothe existing floor
with 6x60mm nylon selfexpansion
675 MAT-01304 BMT-M.69 screws at 600 mm C/C 1 1840
andtopofthepanelfixedwithceilingchannel Sqm.
madeoutof1mmthickGIChannel of size
38x75x38mm duly
fixedtotheexistingceilingwith6x60mmnyl
on self expansion screws at 600
mmC/C. All the tongue and groove joints
ofthe panels have to be properly
cleanedand both the panels have to be
fixed
byapplyingthemixtureofflyashandsodium
silicate in between and
Everestjointingcompoundalltheexposedj
oints. The rate includes cost of
75mmSOLID WALL PANEL panels, G.l.
Floorand ceiling channel. The panels
can beflushed by using paper tape and
Everestjointingcompound allcomplete.

SupplyandfixingCEMENTBONDEDPAR
TICLEBOARDS(IS14276)double
skinpartitionusingwith10MMCEMENT
BONDED PARTICLE
BOARDS made out of G.I. track 1
676 MAT-01307 BMT-M.72 sectionofsize50mmx35mmx0.55mmforfi Sqm 1770
xingtotheroofandfloorandstudsection of
size 48mm x 35mm x
0.55mmplacedintracksectionverticallyat6
10mmintervalsandat1200mmintervals
horizontally fixed to the wall
bymeansofselfexpansionscrewsand
80
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
capstothewallandroof.CEMENTBONDE
DPARTICLEBOARDSistobe
fixed both sides of frame work by
usingself taping screws fixed at every
300mmintervals to the frame work
leaving 3
mmgapbetweentwopanels.Thecostinclu
sive with one coat ofprimer andtwo
coats of smooth finish and cost
andconveyance of all materials to site,
laborchargesetc.,completeasperthedirec
tion ofEngineerin charge.
Supply and fixing of CEMENT
BONDEDPRE-
LAMINATEDPARTICLEBOARDS
double skin partition using with 10
mmCEMENTBONDEDPRE-
LAMINATED
PARTICLEBOARDSmadeoutofG.Itrack
section of size 50 mm x 35mm x0.55mm
for fixing to the roof and 1
677 MAT-01308 BMT-M.73 floorandstudsectionofsize48mmx35mmx Sqm 2440
0.55mmplacedintracksectionverticallyat6
10mmintervalsandat1200mminternalsho
rizontally.Theframeisfixedbymeansofself
expansion screws and caps to the wall
/roof. LAM is to be fixed both sides
oftheframeworkbyusing2mmthickelectro
platedCRflatsectionleaving3mm gap
between two panels. The costinclusive
of cost and conveyance of
allmaterialstosites,othermaterialsinciden
talsand labourchargesasperthedirection
ofEngineerincharges.
Supply and fixing of CEMENT
BONDEDPRE-
LAMINATEDPARTICLEBOARDS
aluminum glazed partitions using 10
MMCEMENTBONDEDPRE-
LAMINATED
PARTICLEBOARDSand5mmthickplain
678 MAT-01310 BMT-M.75 1 3030
glass to full height. Using with
Sqm
LAMtoaheightof0.91meteratbottompanel
and remaining height with
glassandaluminumsectionsanodizedto1
2to 15 microns and of sections of
size37mmx62mmand1.5mmthicknesswit
honemetercentretocentredulyfixedwithcli
pbeadingonbothsidesincludingfixingthefr
ametopillarsby
M.S. flats, bolts and nuts including
costandconveyanceofallmaterialsetc.,co
mpleteasdirectedduringexecution.
Providingandfixing50mmthickSEMIHEIG
679 MAT-01311 BMT-M.76 HT SOLID PVC PARTITION 1sqm 2576
consistingof49mmsandwichPVCpanelm
adeoutof36mmhighdensity

81
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
expandedpolystyrenesheet(E.P.S.-
Thermocole)stuckonbothsidewith2mmthi
ckplain/printed/prelamPVCrigid foam
sheets reinforced with
frameworkmadefrom35mmX5mmM.S.A
ngle.InbetweentwoM.S.Angles5mmthick
plain/printed/prelamheatmouldedPVC‘C’
channelofsize50X100mm with feathered
edges shallbe fixed on the floor &
50X75mm
withfeatherededgesplain/printed/prelam
PVC ‘C’ channel. In between
adjoiningEPS sandwiched PVC
partitions panel5mm
thickX75mm
widthplain/printed/prelamP
VCsheetfeatheredatedgesshallbestucko
nfront & back face using solvent
cementetc. in places where two
partitions
meettofroman‘L’shapethepanelsarejoine
d5mmthickplain/printed/prelamheatmoul
ded“Rajshri”PVC‘L’sectionofsize75mmX
75mmwithfeatherededgesshallbefixedon
front&backside.Thisisdonetomaintainthe
symmetry of design. An additional
5mmthick PVC strip of 40mm width is to
bestuckontheinteriorsideofthe‘C’Channel
usingPVCsolventadhesive,complete as
per direction of Engineer-in-Charge,
manufacture’s specification &drawing
Supply and fixing of PVC Double
SkinPartition.The entire framework shall
becarried out by mild steel section
havingoverall dimensions of 24 X 48mm
with
awallthicknessof1.2mm.Theentireframe
680 MAT-01324 BMT-M.89 work shall be concealed with Sqm. 2175
PVCsection having overall dimensions
of 6 X250mm with a wall thickness of
1mm ±0.3mm both sides.
Glass
provision/Doorprovisioncanbeprovidedal
ongthepartitionwhereverrequired.Partitio
ns can be made full
orhalfasperrequirementcomplete,forfinis
hed itemofwork.
Supply and fixing of partitions made
ofseccolor pre-painted steel (base steel
asper IS 513 of 0.58 mm thick ‘D’
quality,galvanizedasperIS277withZincof
120 GSM).Primer coated with
epoxyprimerof5-
7micronsthick,finishpainted with a
polyester paint of 12-16microns thick
alkyd backer.Section forouter frame
should be 46x52mm,

82
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
section for shutter should be
46x46mm,section for mullion should be
46x70mm,section for beading should be
18x25mmand section for middle and bottom
rail(Lock Rail and Kick Rail) of size shouldbe
23x130mm.The partition should
bepaneledwith9mmpre-laminatedparticle
board to a height of 0.91m fromthe bottom,
and remaining height
with5mmthickplainglassWithEthylPropylene
DiamineMonomer(EPDM)Gaskets.The
sections are to be cut tolength, mitre joined
with corner
bracketCentremullionsaretobefixedusingmull
ioncap.GasketsmadeofEthylPropyleneDiami
neMonomer(EPDM).Cornerbracketsmadeof
CRCAwithzinc phosphate.Mullion caps
made ofGlass filled nylon.The above
framesshould be fixed to the
concrete/masonrywall by means of self
expanding screws,andcomplete
forfinisheditemof work.
FixedPartition:Outerframesectionsize of
681 MAT-01325 BMT-M.90 46x52mm, mullion section shouldbe 1sqm 4477
of46x70mm,fixedbeading
shouldbeof18x25mm.
Fixed Partition with Door:Outer
framesectionsizeof46x52mm,mullionsection
shouldbeof46x70mm,fixedbeading should
682 MAT-01326 BMT-M.91 be of 18x25mm, sectionfor shutter should be 1sqm 5105
of 46x46mm andsection for middle & bottom
should be ofsize23x130mm.

DRYWALLPARTITIONWITH50MMTHICK
V-PANEL
CEMENT BONDED PARTICLE
683 MAT-01327 BMT-M.92 1 548
PLANK-8mm-Availablesize-
Sqm
150mmX2440mmand200mm X2440mm
CEMENTBONDEDPARTICLEPLANK-
684 MAT-01328 BMT-M.93 1 672
10mm- Available size-
Sqm
150mmX2440mmand 200mm X2440mm
CEMENT BONDED PARTICLE
685 MAT-01329 BMT-M.94 1 827
PLANK-12mm- Availablesize-
Sqm
150mmX2440mmand 200mm X2440mm
Note: Items BMT-M.33, BMT-M.34, and BMT-M.35 areremoved
inthesectionM andarebroughtasnewitemsintheSectionDas
BMT-D.18,BMT-D.19andBMT-D.20.
DOORS
N.SECTION (Landingcost–includingloading,costof
conveyance,unloading)

83
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
I.SUB- DOORFRAMES
SECTION
Powder Coated Mild Steel Hallow
singlerebate door frames manufactured
usingcoldrollformedprocesssteelsheetof
1.25 mm thick bright (Cold Rolled
CloseAnnealed(CRCA)andprofilesizeof1
05 x 60 mm conforming to IS 4351 -
2003 including pretreatment,
Galvanizedas per IS:277, zinc
phosphating finishedwithThermosetting
686 MAT-05431 BMT-N.80 Polyurethane paintof Aliphatic Grade 1RM 660
providing high
levelsofscratchresistanceanddurability/E
poxypolyesterpowderforpowder coating
paint thickness 60 –
65microns(Dryfilmthickness)StainlessSt
eelBallBearingButtHinges3mmthickfixedf
lushtotheframewithHinges,BaseTies,Hol
dfastLugs,MortarGuards,shockabsorber
sandprovision for Tower Bolts, Aldrops,
Lock& Strike plates etc. for both single
anddoubleshutterdoors
Mild Steel Hallow single rebate
generalpurposedoorframesmanufacture
dusingcoldrollformedprocesssteelsheeto
f1.25mmthickbright(ColdRolledCloseAn
nealed(CRCA)andprofile-
687 MAT-05432 BMT-N.81 Bofsize105x60mmconforming to IS 1Rm 360
4351 - 2003 includingpretreatment,
phosphating with
Hinges,BaseTies,HoldfastLugs,MortarG
uards, shock absorbers and provisionfor
Tower Bolts, Aldrops, Lock &
Strikeplatesetc. forboth
singleanddoubleshutterdoors
Providingandfixingfactorymadepolyvinyl
chloride (PVC) Door Frame
ofthesize50x47mmwithawallthickness of
5mm, made out of extruded10 mm rigid
PVC foam sheet, mitre cutat two corners
and joined with 2nos. of150mm long
brackets of 15x15mm
688 MAT-01330 BMT-N.01 M.S.squaretube.Thetwoverticaldoorprofil 1Rm 330
esaretobereinforcedwith19x19mmM.S.S
quaretubeof19gauge. The door frame
shall be fixed
tothewallusing65/100mmlongM.S.Screw
s through the frame by using
PVCfasteners.Aminimumof4nos.ofscrew
s to be provided for each
verticalmember & minimum 2nos. for
horizontalmemberetc.completeasper

84
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
manufacturersspecificationanddirectiono
fEngineer-in-Chargeforfinished
itemofwork
SINGLE SIDE PRELAM SOLID
PANELPVCDOORFRAME(CHOUKHAT
):
Providing and fixing factory made
PacsinglesidePrelamdoorframeofthesize
50X47 mm with a wall thickness of5mm,
made out of extruded 5mm rigidPac
single side prelam sheet, meter cutat
two corners and joined with 2nos.
689 MAT-01334 BMT-N.05 of150mmlongbracketsof1515mmMS.Sq 1Rm 330
uare tube. The two vertical
doorprofilesaretobereinforcedwith19X19
mm MS. square tube of 19guage.The
door frame shall be fixed to the
wallusing65/100mmlongMS.Screwsthro
ughtheframebyusingPacfasteners. a
minimum of 4nos. of screwsto be
provided for each vertical
memberandminimum2nos.forhorizontal
memberetc.completeaspermanufacture
specification and directionofEngineer-in-
charge.
Supply and fixing of door frame made
ofhollowextrudedPVCsectionhavingdime
nsions of 40 X 57mm with the
690 MAT-01361 BMT-N.32 wallthicknessof2mm+/- 1RM 237
0.2mmdulyreinforced with seasoned
wood plank atthe hinges side. The door
frame top 2corners shall be metri-cut/
welded. PVCDOORFRAME
Supplyandfixingofdoorframemadeofholl
ow extruded PVC
sectionhavingdimensions of 40 X 46
691 MAT-01362 BMT-N.33 mm with the wallthickness of 2mm +/- 1RM 186
0.2mm dulyreinforced with seasoned
wood plank atthe hinges side. The door
frame top 2cornersshall be
mitrecut/welded
Supply & fixing of Door frames made
ofallformedsectionsof1.25mmthickCRCA
section, size should be
50x60mmwith32mmrebate.Thecorneroft
heframeshouldbewelded.Theframeshoul
692 MAT-01363 BMT-N.34 dbepaintedwithonecoatofprimerandfinish 1RM 215
edpaintedwithpurepolyesterpaint.Thefra
meshouldbeprovidedwithapprovedqualit
ybutthinges of 3 Nos.complete for
finisheditem.:Singleshutter3'-0"x7'-
0"(914.4x2133.6mm) outer frame
sectionsizeof50x 60mm

85
BasicRat
S.No ItemCode escriptionofitem e forSoR
CFMScode Unit 2021-
22 (Rs.)
1 2 3 4 5
Supply & fixing of Door frames made
ofallformedsectionsof1.25mmthickCRCA
section, size should be
50x60mmwith32mmrebate.Thecorneroft
heframeshouldbewelded.Theframeshoul
693 MAT-01364 BMT-N.35 dbepaintedwithonecoatofprimerandfinish 1RM 218
edpaintedwithpurepolyesterpaint.Thefra
meshouldbeprovidedwithapprovedqualit
ybutthinges of 3 Nos.complete for
finisheditem.:Doubleshutter5'-0"x7'-
0"(1524x 2133.6mm) outer frame
section size of50x 60mm

Supplying & fixing ofDoorframe madeof


roll formed section of 1.25 mm
thickCRCA section, size should be 50 x
60mm with 32 mm rebate. The corner
ofthe frame should be welded. The
694 MAT-01365 BMT-N.36 frameshouldbepaintedwithonecoatofprim 1RM 250
erandfinishedpaintedwithpurepolyesterp
aint.Theframeshouldbeprovidedwithappr
ovedqualitybutthinges of 3
Nos.Complete for finisheditem of work.:
Single shutter 3'-0" x 7'-
0"(914.4x2133.6mm) outer frame
sectionsizeof50x 75mm
Supplying & fixing ofDoorframe madeof
roll formed section of 1.25 mm
thickCRCA section, size should be 50 x
60mm with 32 mm rebate. The corner
ofthe frame should be welded. The
695 MAT-01366 BMT-N.37 frameshouldbepaintedwithonecoatofprim 1RM 252
erandfinishedpaintedwithpurepolyesterp
aint.Theframeshouldbeprovidedwithappr
ovedqualitybutthinges of 3
Nos.Complete for finisheditem of work.:
Single shutter 5'-0" x 7'-
0"(1524x2133.6mm)outerframesectionsi
zeof50x 75mm
Providingandfixingdoorframesfabricatedf
romsectionsmadeofgalvanizedsteelpow
dercoated(basesteelasperIS513,galvani
sedasperIS
277withzincof120grams/squaremetre),th
efactorymadesectionarepowdercoatedwi
696 MAT-01367 BMT-N.38 thpurepolyesterpowder of 50-60 microns 1RM 750
thick with
totalcoatedthicknessof1.25mm,sizeofdo
or frame section is of 105 x 60 mmwith a
rebate of 38 mm to accommodate35
mm thick door shutter, with groove
toinsert gasket in the frame section,
framesectionfilledwithpolyurethanefoam,

86
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
cuttolength,andjoinedbywayofwelding,ea
chframeprovidedwith:a)2mmthickMSpo
wdercoatedbutthingesof100mmlong–
3Nos.forsingleshutter,6Nos.fordoublesh
utter.
b)CRCAelectroplatesstiffenersof6Nos. –
3in each vertical.c) 40 mm x200 mm x
1.2 mm hold fasts screwed tostiffeners –
6 Nos. with split end tail. d)Nylon Aldrop
Receiver – 1 No. for
singleshutterframe.e)TieRod– 1No
Providingandfixingofdoorframesfactorym
ade,internaldoorframeswithoutthreshold,
fabricatedfromprepainted cold roll
formed section 100 mmx 60 mm made
of galvanized (base steelas per IS-513
‘D’ quality galvanized asper IS-277 with
Zinc of 120
Gms/sqm)steelcolourcoatedsectionswith
totalcoated thickness of 1 mm primer
coatedwith epoxy primer of 5-7 microns
thickfinish painted with polyester paint of
12-16 microns and back coated with
alkydbacker of 5-7 microns, the frame
697 MAT-01368 BMT-N.39 sectionfilled with polyurethane (PU 1RM 445
Foam) of 40kg/Cu.m and the sections
cut to lengthand mitre joined by means
of 1.25
mmthickCRCAelectroplatedcornerbrack
ets of size 75 x 75 mm and 1.25mm
thick electroplated stiffeners of size150
mm for fixing hold fasts and
hingeswithMSPowdercoatedfittingsa)6N
os
M.S.ZTypeholdfastsmadeof30mmx 3
mm MS flat of 230 mm long, 3
NoseachsizeexpandablePVCcoveredscr
ew type fasteners b) 2.5 mm x 300mm
long ‘T’ hinges /2.5 mm x 50 mm x50
mm x 100 mm two way but hinges
(3Nos for single leaf or 2 Nos for
Doubleleaf/leaf) c)12mmdiaMS tie
rodatbottom with necessary size of nuts
oneitherside.
Providing & fixing
internalprelaminatedPV
Cdoorframeofsize
100 x 45 mm with a wall thickness
of5mm, made of extruded 5 mm
698 MAT-01383 BMT-N.54 PrelamPVCfoamsheet,mitredcutattwoco 1RM 550
rnersandjoinedwithtwonos.of150mm
long brackets of 15 x 15 mm MSsquare
tube, two verticaldoor profilesreinforced
with 40 x 20 MS Tube of
19guagethroughouttheframeandthedoorf
ramefixedtothewallusing65/100mmlong
MSscrewsthroughthe

87
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
framebyusingPVCfastenerswithaminimu
m of 3 nos of screws provided foreach
vertical member and two nos.
forhorizontal, etccompleteas
perdrawingand direction of Engineer
inCharge
PVCDoorframemadeoutofPVCmaterialc
onformingtoIS:10151:1982.Thedoorfram
eshallbemadefromextrudedPVCSectioni
noveralldimensionsof40mmx48mmhavin
gwall thickness of 1.1mm +/-0.3mm
withusual process variation
corresponding toSintex code number Per
699 MAT-01401 BMT-N.72 Rmt. 196
RUPS 414.Theframe shall be
Reinforced with
specialpolymericreinforcementasshowni
ndrawing to take up necessary
hardware.The corner joint shall be mitre
cut andwelded or joined by means of
concealedcleats with necessary screws
fittings.Atierodtobeprovidedatbottom.[La
minated Profile]
Providing and fixing factory made
solidWood Polymer Composite (WPC)
700 BMT-N.83 singleextrudedDoorFramesectionofsize
with encapsulation of 8MM rigid layer
onall the six surfaces. The door frame
willhavearebatof32MM.
Door Frame section of 45x75 MM .
Thetwo Vertical members are to be
joinedtogetherwiththehorizontalmember
using 8x50 MM long MS Star full
threadscrews to be used with reverse
701 MAT-05434 BMT-N.83.A forwardspeedcontrolhanddrillingmachine 1Rm 506
.Theready/assembleddoorframeisfixed
to the wall using hold fast or
boltfasteners.Aminimumof4No.sofscrew
s to be provided for each
verticalmember & minimum 2no.s for
horizontalmember.
Door Frame section of 45x90 MM .
Thetwo Vertical members are to be
joinedtogetherwiththehorizontalmember
using 8x60 MM long MS Star full
threadscrews to be used with reverse
702 MAT-05435 BMT-N.83.B forwardspeedcontrolhanddrillingmachine 1Rm 700
.Theready/assembleddoorframeisfixed
to the wall using hold fast or
boltfasteners.Aminimumof4No.sofscrew
s to be provided for each
verticalmember & minimum 2no.s for
horizontalmember.

88
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
DoorFramesectionof63.5x100MM
.ThetwoVerticalmembersaretobejoinedto
getherwiththehorizontalmember using
8x75 MM long MS
Starfullthreadscrewstobeusedwithrevers
703 MAT-05436 BMT-N.83.C eforwardspeedcontrolhanddrillingmachin 1Rm 805
e.Theready/assembleddoor frame is
fixed to the wall using holdfast or bolt
fasteners.A minimum of 4No.s of screws
to be provided for
eachverticalmember&minimum2no.sforh
orizontalmember.
SupplyandfixingoffactorymadeBathroo
mdoorframeswithoutthreshold,fabricate
dfrompre-paintedcold roll formed section
50mm x 50
mmmadeofgalvanized(basesteelasperIS
– 513 ‘D’ quality, galvanized as perIS-
277 with Zinc of 120 Gms/sqm)
steelcolour coated sections with total
coatedthickness of 1 mm, primer coated
withepoxy primer of 5-7 microns thick,
finishpaintedwithpolyesterpaintof12-
16micronsandbackcoatedwithalkydback
erof5-
7micronsandtheframesectionfilledwithpol
704 MAT-05433 BMT-N.82 yurethane(P.U.Foam) of 40 Kg/Cum; 1RM 445
and the sectionscut to length and mitre
joined by
meansof1.25mmthickCRCAelectroplate
dcorner brackets of size 75 x 75 mm
and1.25mm thick electroplated stiffeners
ofsize150mmforfixingholdfastsandhinge
stogetherwiththefollowingMSPower
coated fitting (Supply and fixing)of
approved make.
(a) 6 Nos M.S. Z. Type hold fasts
madeof30mmx3mmMSflatof230mmlong,
3 Nos each side expandable
PVCcovered screw type
fasteners.
(b) 2.5 mm x 300 mm long ‘T’ hinges
/2.5mm x 50 mm x 100mm two way
buthinges (3 Nos for single leaf or 2 Nos
forDoubleleaf /leaf)
(c)12mmDiaMStierodatbottomwithne
cessary sizeofnutson eitherside.
II.SUB- DOORSHUTTERSWITHOUT
SECTION FRAMES
Flushdoorshutters,solidbondwoodblock
705 MAT-01341 BMT-N.12 board type with teak ply on 1sqm 1790
bothfaces.:25mmthickconformingtoIS:2
202
Flushdoorshutters,solidbondwoodblockb
706 MAT-01342 BMT-N.13 1sqm 1860
oardtypewithteakplyonboth

89
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
faces.: 30 mmthick conforming
toIS:2202
Flushdoorshutters,solidbondwoodblock
MAT-01343 BMT-N.14 board type with teak ply on 1sqm 2031
707 bothfaces.:35mmthickconformingtoIS:2
202
Flushdoorshutters,solidbondwoodblock
MAT-01344 BMT-N.15 board type with commercial plyon 1sqm 1041
708 both faces.: 25 mmthick
conformingtoIS:2202
Flushdoorshutters,solidbondwoodblock
MAT-01345 BMT-N.16 board type with commercial ply onboth 1sqm 1232
709 faces.: 30 mmthick conforming
toIS:2202
Flushdoorshutters,solidbondwoodblock
MAT-01346 BMT-N.17 board type with commercial ply onboth 1sqm 1396
710 faces.: 35 mmthick conforming
toIS:2202
Flushdoorshutters,solidbondwoodblock
MAT-01347 BMT-N.18 board type with commercial ply onboth 1sqm 1564
711 faces.: 40 mmthick conforming
toIS:2202
Flushdoorshutters,solidbondwoodblock
board type with teak veneer
MAT-01348 BMT-N.19 ononefaceandcommercialplyonanoth 1sqm 1960
712
erface(lipping):20mmthickconforming
toIS:2202
Flushdoorshutters,solidbondwoodblockb
oardtypewithteakveneeronone face and
MAT-01349 BMT-N.20 commercial ply on anotherface (lipping): 1sqm 1893
713
25 mmthick conforming toIS:2202

Flushdoorshutters,solidbondwoodblockb
oardtypewithteakveneeronone face and
MAT-01350 BMT-N.21 commercial ply on anotherface (lipping): 1sqm 2096
714
30 mmthick conforming toIS:2202

Flushdoorshutters,solidbondwoodblockb
oardtypewithteakveneeronone face and
MAT-01351 BMT-N.22 commercial ply on anotherface (lipping): 1sqm 2285
715
35 mmthick conforming toIS:2202

Flushdoorshutters,solidbondwoodblockb
oardtypewithteakveneeronone face and
MAT-01352 BMT-N.23 commercial ply on anotherface (lipping): 1sqm 2612
716
40 mmthick conforming toIS:2202

SupplyandfixingCementBondedParticl 1
717 MAT-01354 BMT-N.25 1889
eBoard(IS14276)singledoor Sqm

90
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
shutterusingwith16MMCementBonded
Particle Board with all-round
"U"sectionofsize12mmx18mmx12mmm
adefrom0.6mmthickgalvanized,colorquot
edcoldrolledsteelprofileswithnecessarys
crewsfixedatevery
304.8 mm intervals. Thecost inclusiveof
MS Nickel coated Aldrops of size
255mmlong2Nos.,200mmlongtowerbolts
1 No., 125 mm handles 2 Nos. 300mm
long "T" hinge cost and conveyanceof all
materials at site and
applying1coatprimer,1coatofluppumand
2coats of synthetic enamel paint as
perapproveddesignforfinisheditemofwor
k.
Supply and fixing ofCement
BondedParticleBoard(IS14276)doorsh
uttersusingwith16MMCementBondedPa
rticleBoardwithallroundstyle “U” size of
20mmx18mm x20mmmade from
0.6mm thick galvanized pre-
paintedcoldrolledsteelprofileswithCemen
tBondedParticleBoardseparatingtwoshut
terwith30mmx18mmx30mmSteppedlippi 1
718 MAT-01355 BMT-N.26 ngwith necessary screws fixed at every Sqm 2654
1’-0”(304.8mm)intervals.MsNickelcoated
250 mm long aldrops 2 no’s, MSpowder
coated 250mm long tower bolt2no’s , &
2no’s MS powder coated 125mm long
grip handle. Including cost
andconveyance of all materials at site
andapplying one coat of primer, 2 coats
oflappum and 2 coats of synthetic
enamelpaintasperapproveddesignforfini
shed itemofwork.

Supply and fixing of CEMENT


BONDEDPARTICLEBOARDdoubledo
orshutterusing16MMCEMENTBONDE
DPARTICLEBOARDLAMwith
allround“U”sectionsizeof20mmx18mm
x20mm made from 0.6mm
thickgalvanizedpre-
719 MAT-01408 BMT-N.79 1 2687
paintedcoldrosteelprofileswithCEMENT
Sqm
BONDEDPARTICLE BOARD LAM
separating twoshutter with 30mm x lled
20mm x30mmsteppedlipping with
necessaryscrewsfixedat every 1’0”
(304.8mm)intervals.ThecostinclusiveofM
SNickel
coated250mmlongaldrops2no’s,MSpow
dercoated 125mmlong grip handle, 2
no’s M.S.P.C.
Doorstopper.Includingcostandconveyan
ce

91
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
of all materials at site labor charges
etc.,completefinisheditemofwork.
Supply and fixing of CEMENT
BONDEDPRE-LAMINATED PARTICLE
BOARDS door shutter made out of
Usectionsofsize12x14x12madefrom0.6
mmthickppssectionswith12MMCEMENT
BONDEDPRE-LAMINATED 1
MAT-01359 BMT-N.30 PARTICLEBOARDSwithnecessaryscre Sqm 2205
720
wsfixedatevery1’.0”interwells.The
hardware consists of 250mm longaldrop
– 2 Nos.150mm Handle- 1 No ,150 mm
long ms powder coated
towerbolt1no.nicklecoated.Thecostisincl
usiveofallincidentals,labortransportation
charges.
SupplyandfixingofBOARD(conforming
toIS 14862) door shutterwith all-round
style “U” lipping size 15 x18 x 15 mm
made from 0.8 mm thickpowder coated
cold rolled steel
profileswith16mmthickV-
MAT-01392 BMT-N.63 BOARDwithnecessary screws fixed at 1 1350
721 1’-0” interval250 mm long aldrops 2 nos. Sqm
M.S. nickelcoated 250 mm long 1 no.
M.S. TowerBolts Including cost and
conveyance ofall materials at site and
applying 1 coatof primer, 2 coats of
luppum and 2
coatsofsyntheticenamelpaintasperappro
veddesignforfinisheditemofwork.
Supply and fixing of Cement
BondedParticle Board (IS 14276) LAM
doubledoorshutterusing16MMCEMEN
TBONDEDPRE-LAMINATEDPARTICLE
BOARDS with all round “U” section
sizeof 20mm x 18mm x 20mm made
from0.6mm thick galvanized pre-painted
coldrolled steel profiles with Cement
MAT-01356 BMT-N.27 BondedParticleBoard(IS14276)LAMsep 1 1939
aratingtwoshutterwith30mmx20mmx30m Sqm
722
msteppedlippingwithnecessaryscrewsfix
edatevery1’0”(304.8mm) intervals. The
cost
inclusiveofMSNickelcoated250mmlongal
drops2no’s,MSpowdercoated125mm
long grip handle, 2 no’s
M.S.P.C.Doorstopper.Includingcostand
conveyance of all materials at
sitelabourchargesetc.,completefinishedit
em ofwork.
Mouldedpanelsolidcoreflushdoorsusingw 1
723 MAT-01376 BMT-N.47 1637
ater-resistanthardwoodfibre Sqm

92
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
HDF / MDF fibre boards skins of 2.5
mmthickdoors- 30mmthick
Mouldedpanelsolidcoreflushdoorsusing
MAT-01377 BMT-N.48 water-resistanthardwoodfibreHDF / MDF 1 1810
724 Sqm
fibre boards skins of 2.5 mmthickdoors-
35mmthick
Solid core membrane flush doors
MAT-01378 BMT-N.49 usingrigid PVC membrane of 0.3 mm 1 1350
725 Sqm
thick ofdifferent elegant shades doors -
30 mmthick
Solid core membrane flush doors
MAT-01379 BMT-N.50 usingrigid PVC membrane of 0.3 mm 1 1502
726 Sqm
thick ofdifferent elegant shades doors -
35 mmthick
Providingandfixing35mmthickBRANDF
ACTORYMADEMOULDED
DOORSHUTTERconsistingofsoldcoresi
ngleleafflushdoorof30mmthickness,lippe
dwith15mm(5mmX3)thickX30mmwidtho
nonestilesandtoprailsand10mm(5mmX2)
thickX30mmwidthontheotherstilesandbot
tom rails. The inner panel
laminatedwith2mmthicktermiteproof,wat
MAT-01335 BMT-N.06 erproofandfireresistantmouldedPacshee 1sqm 2726
727 t with 2,4,6 raised panel design
indifferent panel and / or
prelamcolourson one side after routing
the mouldeddesign on flush door and
2mm
prelamPacsheetonothersideusingrubber
adhesiveonflushdoorandsolventcementa
dhesiveonPaclippingetc.complete as per
direction of Engineer-in-
Charge,manufacturespecificationand
drawing
Supplyandfixingofdoorshuttersmadeofr
igidPVCextrudedhollowsectionof20m
mX200mm
withthewallthicknessof1.0mm+/-
0.1mmequally divided into 4 no's with
tongueand groove locking
arrangements.
MAT-01360 BMT-N.31 Theshutterframeismadeof30mmX79m Sqm. 1690
728 mwiththewallthicknessof1.5mm
+/-0.15mm section mitre-cut and
joinedat4cornerswith125mmX225mmpla
sticbrackets.Theshuttershallbehorizontal
lyreinforcedwith2no'sof8mm PVC rods.
Teak wood batons
shallbereinforcedinsidethedoorshutterdu
ring the fabrication of the door
shutteratthosepointswhereverthehardwa
reisfixedontothedoor shutter.

93
BasicRat
S.No ItemCode Descriptionofitem e forSoR
CFMScode Unit 2021-
22 (Rs.)
1 2 3 4 5
Supply & Fixing SOLID STEEL
DOORdoor shutter made out of G I
PrecoatedSheetwithanaveragewallthick
nessof
0.35 mm on both sides. MS Tube
havingdimensions of 19 x 19 mm is
insertedalong the hinge side of the door, 1
MAT-01381 BMT-N.52 Sqm 1400
core ofthe door shutter filled with High
729
DensityPolyurethanefoaminjectedwithth
ehelp of hydraulic injection method,
foursidesofthedoorcoveredwithGIPrecoa
tedSheetandthehardwarelocationsreinfo
rcedwithsuitablewoodenblocksasperdra
wingandstickersindicatinglocationoftheh
ardware pasted at appropriate
places,etccomplete
SupplyandfixingofBOARD(conforming
toIS 14862) 12 mm thickdoor shutter
of size 6’0” x 2’6” withall-round style
“U” lipping size 15 x 14 x
15mmmadefrom0.8mmthickpowdercoat
edcoldrolledsteelprofileswithnecessary
MAT-01393 BMT-N.64 screws fixed at 1’-0” interval250 mm 1 1160
730 long aldrops 2 nos. M.S. nickelcoated Sqm
250 mm long 1 no. M.S. TowerBolts
Including cost and conveyance ofall
materials at site and applying 1 coatof
primer, 2 coats of luppum and 2
coatsofsyntheticenamelpaintasperappro
veddesignforfinisheditemofwork.

Providingof35mmthickFacotrymadePr
elaminated ABS
(AcrolynitrileButadyne Styrene) Door
shuttermouldedindifferentdesigns,cons
istingof all round Frame made out of
waterproof solid foam PVC bar of
size20x32mm, reinforced by 32x 32mm
MAT-01397 BMT-N.68 1 6200
- 2nos. for vertical made out of
Sqm
731 LVL(Laminated Veneer Lumber),
corematerial of 32 mm thick high
densitycraft paper honey comb
board,sandwiched
onbothsideswithprelaminated ABS
sheetthickness of1.5mm .PVC edge
banding of size0.45mm on the vertical
sides.for eachshutter and ISI make S.S
round
lockcompleteforfinisheditemofwork
III.SUB- DOORSWITHSHUTTERS &FRAMES
SECTION
Providingand fixing 30mm thick
732 MAT-01331 BMT-N.02 1 2270
Solidpanel PVC door shutter
Sqm
consisting
offramemadeoutofM.S.tubesof19

94
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
gaugethicknessandsizeof19mmx19mmf
orstiles,&15mmx15mmfortop&bottomrail
s.M.S.frameshallhave a coat of steel
primers of
approvedmakeandmanufacture.M.S.fra
meshall becoveredwith5mm thick
heatmoulded PVC ‘C’ channel of size 30
x50mmformingstiles,and5mmthick,75m
m wide PVC sheets for top rail,
lockrail&bottomrailoneitherside,and10m
m(5mmx2)thick,20mmwidecross PVC
sheet asgapinsert for toprail & bottom
rail. Panelling of 5mm thickPVC sheet to
be fitted in the M.S. framewelded /
sealed to the stiles & rails
with30mmwidex5mmthickPVCsheetbea
dingoneitherside,andjoinedtogether with
solvent cement
adhesiveetc.Anadditional5mmthickPVCs
tripof20mmwidthistobestuckontheinterior
sideofthe‘C’ChannelusingPVC solvent
adhesive. Complete as
perdirectionofEngineer-in-
charge,manufacturer’sspecification
&drawingforfinisheditemofwork.
Providingandfixing30mmthickBRAND
FACTORY MADE
BOTHSIDEPRELAMSOLID
PANELPVCDOOR
SHUTTER consisting of frame
madeout of MS. Tubes of 19gauge
thicknessand size of 19mmX19mm for
stiles,
topandbottomrails.MS.Frameshallhavea
coatofsteelprimersofapprovedmakeand
manufacture.MS.Framecovered with
5mm thick heat mouldedPrelam Pac ‘C’
733 MAT-01332 BMT-N.03 channel of size 1sqm 2515
30mmthickness,70mmwidthoutofwhich5
0mm shall be flat and 20mm shall
betaperedin450angleoneithersideformin
gstiles;and5mmthick,95mmwidePrelamP
ac sheetoutofwhich75mm shall be flat
and 20mm shall betapered in 450 on the
inner side to formtop and bottom rail
115mm widePrelamPac sheet out of
which 75mm shall beflat and 20mm shall
be tapered on bothsides to form lock
rail. Top, bottom andlock rail shall be
provided either side
ofthepanel.10mm(5mmX2)thick,20mmwi
decrossPacsheetshallbeprovidedasgapi
nsertfortopandbottom rail. Panelling of
5mm thick bothside Prelam Pac sheet to
befitted in
theMS.Framewelded/sealedtothestiles

95
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
&railswith7mm(5mm+2mm)thickX15mm
wide Pac sheet beading on
innerside,andjoinedtogetherwithsolventc
ement adhesive etc. an additional
5mmthick Pac strip of 20mm width is to
bestuckontheinteriorsideofthe‘C’channel
usingPacsolventcementadhesive etc.
complete as per directionofEngineer–in-
charge,manufacturespecificationanddra
wing.
Providingandfixing30mmthickBRANDF
ACTORYMADESOLIDSINGLESIDE
PRELAMPANELPVC
DOOR SHUTTER consisting of
framemadeoutofMS.Tubesof19gaugethi
ckness and size of 19mmX19mm
forstiles,and15mmX15mmfortopandbott
om rails. The MS. Frame shall
haveacoatofsteelprimersofapprovedmak
eandmanufacture.MS.Framecovered
with 5mm thick heat mouldedsingle side
Prelam Pac ‘C’ channel
ofsize30mmX50mmtoformstiles.5mmthi
ck&75mmwidesinglesideprelimPac
sheets shall be for the top, bottomand
734 lock rails. Panelling of 5mm thickone
MAT-01333 BMT-N.04 1sqm 2198
sidePacsheet tobefitted in
theMS.Frameandsealedtothefront(prela
mside)stilesandrails(whichshould have a
5mm 45 bent portion
asbeading)andattachedtotheback(white/i
vory) stiles and rails
whichshouldhavea10mm900bentportion
as beading ) using 2nos. 15mm wide
X5mmthickPacsheetbeadinginsidethe
90bentbeading.Allstiles,railsandbeading
s are to be joined to the panelusing
solvent cement etc. an
additional5mmthickPacstripof20mmwidt
htobe stuck on the interior side of the
‘C”channelusingPacsolventcementadhe
siveand10mm(5mmX2)thick,20mm wide
cross Pac sheet to be fittedas gap insert
for top and bottom rail etc.complete as
per direction of Engineer –in-
Charge,manufacturespecificationand
drawing.
MOULDEDPVCDOOR-WOODFREE
Providing and fixing 30mm thick
BrandfactorymadeMouldeddoorshutter-
735 MAT-01336 BMT-N.07 wood free consisting of frame made 1sqm 2265
outofMS.tubes19gaugethicknessandsize
of 25mmX25mm for stiles, top
andbottomrails.MS.Frameshall havea

96
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
coat of steel primers. The inner panelshall
consist of 25mm thick High
densityEPSconformingtoIS4671-
1984bounded with 2mm thick termite
proof,water proof and fire resistant
mouldedPac sheet with 2,4,6 raised panel
designin different plain and / or prelam
coloursafter routing to the moulded design
onone side and 2mm plain and / or prelamPac
sheet on other side of the
EPS.Theedgeofpaneltobesealedwithlipping of
10mm wide PVC sheet bottom(made by
sticking 2 rigid foam sheet
of5mmthicknessusingPacsolventcement) and
stiles sides 25mm(5mmX5)thick and 30mm
width Pac sheet
fittedalongMs.Tubeforlockprovisionforlock
height 5mm thick Pac sheet of
size150mmX100mmfixedwithupperandlower
face of inner side of EPS
Paneletc.CompleteasperdirectionofEngineer–
in-
Charge,manufacturespecificationanddrawing
Providing and fixing 30mm thick
BRANDFACTORYMADEWIREMESHSOLID
PVCDOORSHUTTERconsistingofframemade
outofM.S.tubesof19gaugethicknessandsizeof1
9mmX19mm for stiles and 15mmfortop, lock
& bottom rails. MS. Frame shallhave a coat of
steel primers of
approvedmakeandmanufacture.19mmX19mm
M.S. square tubes shall be covered
with5mmthickheatmouldedPVC‘C’channel of
size 30mm thickness,
90mmwidthoutofwhich75mmshallbeflatand
15mm shall be flat and 15mm shallbe bent in
736 MAT-01337 BMT-N.08 900 on the inner side to 1sqm 2000
fromtopandbottomrailland130mm widePVC
sheet out ofwhich100mm shallbe flat and
154mm shall be bent in
900onbothsidetofromlockrail,10mm(5mmX2)
thick, 20mm wide crossPVC sheet as gap
insert for top rail
&bottomrail.PanelwillbeofG.I.wiremesh of
24gauge to be fitted in by ’C’channel of size
35mm X10mm on
theeithersideinthestiles.Theinnerside‘C’chann
elisfixedby19mmX19mmMS.Tubeonbothsides
withscrews.Thewiremeshintopbottom&lockraili
s sealed with15mm X 15mm tube withG.I.wire
10mm(5mmX2) thick
PVCstripof25mmwidthistobestuck&nailson

97
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
bothsideofG.I.wiremeshinterioratthe top,
bottom & lock rail. An additional5mm
thick PVC srip of 20mm width is tobe
stuck on the interior side ofthe
‘C’channelusingPVCsolventcementadhe
sive etc. complete as per
directionofEngineer-in-
charge,manufacturer’sspecification&
drawings
Providingandfixingframemadefrom
1.2 mm powder coated cold rolled
steelprofilesofoverallsectionsizeof60mm
x45 mmwith 21mmrivet
forshutterwithnecessarystiffenershinges
andscrews. BOARD (IS 14862) shutter
withall-round style “U” lipping of size 15
737 MAT-01394 BMT-N.65 1 1750
x 18x 15 mm made from 0.8 mm thick
Sqm
CRCApowder coated steel profile with
16 mmthickV-
boardwithnecessaryscrewsfixed at every
1’-0” interval 250 mm longaldrops 2 nos.
M.S. nickel coated
250mmlong1no.M.S.TowerBoltsIncludin
gcostandconveyance.Onecoat of primer,
2 coats of luppum and 2coats of
synthetic enamel paint as
perapprovedcolour,labourchargesetc.
Providingandfixingofdoorframemadefro
mcoldrollformedsectionsmade of
galvanized (Base steel as perIS277 with
zinc of 120 Gms/sqm) colourcoated
steel sections with total
coatedthicknessof1mm,primercoatedwit
hepoxy primer coat of 5-7 microns
thick,finish paint with polyester paint of
12-16microns. The Section
fordoorframeisto be filled with
polyurethane (P.U)
formof40kg/m3.Overallsizeofframesectio
738 MAT-01357 BMT-N.28 nshouldbeof50mmx50mm.Withnecessar 1 3800
ycornerbrackets,stiffeners, hinges, and Sqm
screws. CementBonded particle board
shutter“SingleLeaf” with all round styles
“U” section ofsize 12m x 18m x 12mm
made from 0.6mm thick galvanized,
colour coated
coldrolledsteelprofileswith16mmthickCe
mentBondedparticleBoardwithnecessary
screwsfixedatevery1’-0”(304.8mm)
intervals. The cost
inclusiveofMSnickelcoatedAldropofsize2
50mm long 2nos. 200mm long
towerbolt1no., 125mm handles2nos.,
costand conveyance of all materials at
siteand applying onecoat primer , one
coatofluppumandtwocoatsofsyntheticen
amelpaintasperapproveddesign

98
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
forfinisheditem ofwork
DOORS FRAMES (COLOUR
COATEDSTEELSECTIONS)&SHUTTE
RUSING CEMENT BONDED
PARTICLEBOARDASPERIS14276:
739 ITEMDELETED
TO 742 BMT-
N.40toBMT
-N.43
Supplying and fixing door shutter,
withshutterframeandinfillpanelmadefr
omPVCmaterialconformingtoIS:10151-
1982, the shutter frame made outof PVC
extruded sections having
overalldimension of 47 mm x 33 mm
with wallthickness of 1.2mm + 0.3mm
with usualprocess variation, the shutter
frame withtapered shape to provide
better grip tothe infill panel end to drain
743 MAT-01373 BMT-N.44 out the 1 910
waterTheInfillpanelismadeoutofPVCSect Sqm
ions having Overall Dimensions of200
mm x 20 mm with wall thickness of1mm
+ 0.2mm, the shutter frames
mitrecutandjoinedatthecorner,byprovidin
g Polymeric “ L” type corners totake
hardware & fixtures fixed with 10-
20mmcountersunkfullythreadedparallels
hanksteelscrews,allthehardwarelocation
sreinforcedwithspecial polymeric bars as
per
drawings,stickersshowinglocationsofdiff
erenthardware pasted on the shutter,
the
infillpanelsjoinedbytongueandgroovemet
hod.
Providing&FixingofScientificDoorswithm
etaldoorframesanddoorshutters made of
galvanize steel (basesteel as per IS 513
of 0.58 mm thick Dquality, galvanized as
per IS 277
withZincof120GSM)coatedwithZincPhos
phate Primer to receive any
paintonsiteorfinishedwithThermosettingP
744 MAT-01374 BMT-N.45 olyurethanepaintofAliphaticGradeprovidi 1 9348
nghighlevelsofscratchresistanceanddura Sqm
bility/Epoxypolyesterpowderforpowderco
atingpaint thickness 50-60 microns (Dry
filmthickness) outer frame section of 100
x58 mm x 1.2 mm thick,shuttersectionof
0.80mmthickgalvanizedsteelsheetpress
ed(rollformed)for46mmthickfully flush,
double skin door shell seamjoints at stile
edges, in-fill of
honeycombkraftpaperusedtogivetherequ
ired

99
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
rigidity and effective acoustic
insulationwith6”Tower bolt–1No., 6”
Dhandles
–2Nos.,10”Aldrop–1No.,ButtHinges–
3Nos,MortiseLockofapproved quality – 1
No, frames fixed tothe
concrete/masonry wall by means
ofselfexpandingscrewscompleteforfinish
editemofworkforSingleleafDoor
Providing&FixingofScientificDoorswithm
etaldoorframesanddoorshutters made of
galvanize steel (basesteel as per IS 513
of 0.58 mm thick Dquality, galvanized as
per IS 277
withZincof120GSM).coatedwithZincPho
sphate Primer to receive any
paintonsiteorfinishedwithThermosetting
PolyurethanepaintofAliphaticGradeprovi
dinghighlevelsofscratchresistanceanddu
rability/Epoxypolyesterpowderforpowder
coatingpaint thickness 50-60 microns
745 MAT-01375 BMT-N.46 (Dry filmthickness) outer frame section 1 9971
of 100 x58 mm x 1.2 Sqm
mmthick,shuttersectionof
0.80mmthickgalvanizedsteelsheetpresse
d(rollformed)for46mmthickfully flush,
double skin door shell seamjoints at stile
edges, in-fill of
honeycombkraftpaperusedtogivetherequ
iredrigidity and effective acoustic
insulationwith6”Towerbolt–
2Nos.,6”Dhandles – 2 Nos.,10” Aldrop –
1 No.,Butt Hinges – 6 Nos,Mortise Lock
ofapproved quality – 1 No, frames fixed
tothe concrete/masonry wall by means
ofselfexpandingscrewscompleteforfinish
editemofworkforDoubleleafDoor

Providing & fixing 30 mm thick


solidpanel PVC door shutter
consisting
offramemadeoutof19guageM.Stubeof
19 x 19 mm for stiles, top & bottomrail,
with a coat ofprimer of
approvedmake.M.S. Frame coveredwith
746 MAT-01380 BMT-N.51 1 2750
5 mmthick heat moulded PVC “C”
Sqm
channel ofsize of 30 x 50 mmforming
stiles,
5mmthick75mmwidePVCsheetfortop,
lock & bottom rail on either side20mm
wide cross PVC sheet as gap
insertfortop&bottomrail,panellingof10mm
(+/-)(5mm+5mm)”thickPVCsheetfitted in
the M.S. frame welded
/sealedtothestiles,oneithersidejoinedtog
etherwithsolventcementadhesiveetc.,ad
ditional5mmthick

100
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
PVC strip of 20 mm width stuck on
theinteriorsideoftheCchannelusingsolve
ntcement,completeasperdirectionofEngi
neer–in–
charge,manufacturersspecification.
Supplying & fixing SINGLE PANEL
30mm thick PVC DOOR, door
shutterswithshutterframeandInfillpanel
madefromPVCmaterial,theshutterframe
madeoutofPVCextrudedsections having
overall dimensions of 60mm x 30 mm
with wall thickness of 1.3mm ± 0.3 mm,
747 MAT-01382 BMT-N.53 with the Infill panel madeout of multi 1 2350
chambered seamless Sqm
hollowPVCextrudedpanelhavingoveralldi
mensions of 610 mm x 20 mm
havingwall thickness 1 mm ± 0.2 mm
with theshutterframemetercut
andjoinedatcorners and all the hardware
locationsreinforcedwithspecialpolymeric
barsasperdrawingincludingprovidingspe
cial PVC braket on hinge side,
etccomplete
Supply & Fixing of Powder Coated
MildSteel doors, frames & shutters
madeofSkinpassgalvanizedIronsheetcon
forming to Base Steel as per IS 513“D”
Quality, Galvanized as per IS 277with
Hot Zinc Coating of120 grams /Sq.Mtr
with powder coatingof thickness60-65
Microns, frame with 1.2mm thickSkin
pass Galvanized Iron sheet formedto
single rebate profile of ize 100 mm X58
mm and filled with in-fill
Polyurethanefoam, the Door Shutters
are with
748 MAT-01384 BMT-N.55 1 10800
0.80mmthickSkinpassGalvanizedIronSh
Sqm
eet formed to provide a 46 mm thickfully
flush, double skin door shell withLock
Seam joints at stile edges, fittedwithin-
fillofHoneycombKraftPaperand coated
with polyesterpowders
ofPurepolyester/epoxypolyesterorpolyur
ethane powder for powder coatingof
thickness 60 – 65 microns and
arecoated with ZincPhosphate
Primertoreceive any paint on site or
finished
withThermosettingPolyurethanepaintofAl
iphatic Grade providing high levels
ofscratchresistanceanddurability,theShu
tter provided with 6 MM clear
floatvisionglassinCircular,SquareorRecta
ngularshapes,StainlessSteelBallBearing
ButtHinges3mmthickfixedflushtothefram
eandshutter

101
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
(Profile102x76x3mmthick).MortiseSash
Lock with Lever Handles, MortiseDead
Bolt, etc for industrial,
commercial,residential,cleanroom
applications
Supply&FixingofStainlesssteeldoors,fr
ames&shuttersmadeofstainlesssteelgra
de304ofhairlinefinish, frame with 1.2mm
thick formed tosingle rebate profile of ize
100 mm X 58mmandfilledwithin-
fillPolyurethanefoam, the Door Shutters
are with
0.80mmthickStainlesssteelSheetformedt
oprovidea46mmthickfullyflush,double 1
749 MAT-01385 BMT-N.56 skin door shell with Lock Seamjoints at Sqm 20240
stile edges, fitted with in-fill
ofHoneycombKraftPaper,theShutterprovi
dedwith6MMclearfloatvisionglass in
Circular, Square or
Rectangularshapes,StainlessSteelBallB
earingButt Hinges 3 mm thick fixed flush
to theframe and shutter (Profile
102x76x3mmthick).MortiseSashLockwit
hLeverHandles,MortiseDeadBolt,etcforin
dustrial,commercial,residential,cleanroo
m applications.
Supply & Fixing of Powder Coated
FireRated doors, frames & shutters
madeofSkinpassgalvanizedIronsheetcon
forming to Base Steel as per IS 513“D”
Quality, Galvanized as per IS 277with
Hot Zinc Coating of120 grams /Sq.Mtr
with powder coatingof thickness60-65
Microns, frame with 1.2mm thickSkin
pass Galvanized Iron sheet formedto
double rebate profile of ize 143 mm
X58mmwithmaximumbendingradiusof
1.4mmandfilledwithin-
750 MAT-01386 BMT-N.57 fillPolyurethanefoam,theDoorShuttersar 1 12820
ewith0.80mmthickSkinpassGalvanized Sqm
Iron Sheet formed to providea 46 mm
thick fully flush, double skindoor shell
with Lock Seam joints at
stileedges,fittedwithin-
fillofHoneycombKraft Paper and coated
with
polyesterpowdersofPurepolyester/epoxy
polyesterorpolyurethanepowderforpowd
er coatingof thickness 60 –
65micronsandarecoatedwithZincPhosph
ate Primer to receive any
paintonsiteorfinishedwithThermosettingP
olyurethanepaintofAliphaticGradeprovidi
nghighlevelsofscratchresistanceanddura
bility,theShutterprovidedwith6MMclearflo
atvision

102
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
glass in Circular, Square or
Rectangularshapes,StainlessSteelBallB
earingButt Hinges 3 mm thick fixed flush
to theframe and shutter (Profile
102x76x3mmthick).MortiseSashLockwit
hLeverHandles, Mortise Dead Bolt, etc
for 120minutes Fire Rated door
conforming toIS:3614(Part2)1992
Supply & Fixing of Powder Coated
FireRated doors, frames & shutters
madeofSkinpassgalvanizedIronsheetcon
forming to Base Steel as per IS 513“D”
Quality, Galvanized as per IS 277with
Hot Zinc Coating of120 grams /Sq.Mtr
with powder coatingof thickness60-65
Microns, frame with 1.2mm thickSkin
pass Galvanized Iron sheet formedto
double rebate profile of ize 143 mm
X58mmwithmaximumbendingradiusof
1.4mmandfilledwithin-
fillPolyurethanefoam,theDoorShuttersar
ewith0.80mmthickSkinpassGalvanized
Iron Sheet formed to providea 46 mm
thick fully flush, double skindoor shell 1
751 MAT-01387 BMT-N.58 Sqm 12150
with Lock Seam joints at
stileedges,fittedwithin-
fillofHoneycombKraft Paper and coated
with
polyesterpowdersofPurepolyester/epoxy
polyesterorpolyurethanepowderforpowd
er coatingof thickness 60 –
65micronsandarecoatedwithZincPhosph
ate Primer to receive any
paintonsiteorfinishedwithThermosettingP
olyurethanepaintofAliphaticGradeprovidi
nghighlevelsofscratchresistanceanddura
bility,theShutterprovidedwith6MMclearflo
atvisionglass in Circular, Square or
Rectangularshapes,StainlessSteelBallB
earingButt Hinges 3 mm thick fixed flush
to theframe and shutter (Profile
102x76x3mmthick).MortiseSashLockwit
hLeverHandles, Mortise Dead Bolt, etc
for 60minutes Fire Rated door
conforming toIS:3614(Part2)1992
Supply & Fixing of Stainless steel
FireRated doors, frames & shutters
madeofStainless steel of 304 grade
hairlinefinish, frame with 1.2mm thick 1
752 MAT-01388 BMT-N.59 Sqm 19280
Stainlesssteel of 304 grade hairline
finish
sheetformedtodoublerebateprofileofize
143mmX58mmwithmaximumbending
radius of 1.4 mm and filled within-fill
Polyurethane foam, the Door

103
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Shuttersarewith0.80mmthickStainlessste
elof304gradehairlinefinish Sheet formed
to provide a 46 mmthick fully flush,
double skin door
shellwithLockSeamjointsatstileedges,fitt
edwithin-
fillofHoneycombKraftPaperandcoatedwit
hpolyesterpowdersofPurepolyester/epox
ypolyesterorpolyurethanepowderforpow
der coatingof thickness 60 –
65micronsandarecoatedwithZincPhosph
ate Primer to receive any
paintonsiteorfinishedwithThermosettingP
olyurethanepaintofAliphaticGradeprovidi
nghighlevelsofscratchresistanceanddura
bility,theShutterprovidedwith6MMclearflo
atvisionglass in Circular, Square or
Rectangularshapes,StainlessSteelBallB
earingButt Hinges 3 mm thick fixed flush
to theframe and shutter (Profile
102x76x3mmthick).MortiseSashLockwit
hLeverHandles, Mortise Dead Bolt, etc
for 120minutes Fire Rated door
conforming toIS:3614(Part2)1992

Supply & Fixing of Stainless steel


FireRated doors, frames & shutters
madeofStainless steel of 304 grade
hairlinefinish, frame with 1.2mm thick
Stainlesssteel of 304 grade hairline
finish
sheetformedtodoublerebateprofileofize
143mmX58mmwithmaximumbending
radius of 1.4 mm and filled within-
fillPolyurethanefoam,theDoorShuttersar
ewith0.80mmthickStainlesssteelof304gr
adehairlinefinish Sheet formed to
MAT-01389 BMT-N.60 provide a 46 mmthick fully flush, double 1 17650
753 Sqm
skin door
shellwithLockSeamjointsatstileedges,fitt
edwithin-
fillofHoneycombKraftPaperandcoatedwit
hpolyesterpowdersofPurepolyester/epox
ypolyesterorpolyurethanepowderforpow
der coatingof thickness 60 –
65micronsandarecoatedwithZincPhosph
ate Primer to receive any
paintonsiteorfinishedwithThermosettingP
olyurethanepaintofAliphaticGradeprovidi
nghighlevelsofscratchresistanceanddura
bility,theShutterprovidedwith6MMclearflo
atvisionglass in Circular, Square or
Rectangularshapes,StainlessSteelBallB
earingButtHinges3mmthickfixedflushtoth
e

104
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
frame and shutter (Profile
102x76x3mmthick).MortiseSashLockwit
hLeverHandles, Mortise Dead Bolt, etc
for 60minutes Fire Rated door
conforming toIS:3614(Part2)1992
Supply & Fixing of Lead Lined
Cleanroomdoorsframesandshuttersm
adeofSkinpassgalvanizedIronsheet(Conf
ormtoBaseSteelasperIS
513 “D” Quality, Galvanized as per
IS277withHotZincCoatingof120grams
/Sq.Mtr).withpowdercoatingofthickness6
0-
65Microns,frameof1.60mmthickgalvaniz
edsteelsheet(ConformtoIS277)formedto
Single/doublerebateprofileofsize100mm
X58mm/143x58mm,doorframeswithasin
gle/multiLayerofLeadsheetvaryingthickn
essfrom3mm
/1mmto2mmdependsonradiationlevel,th
eshutterwith1.2mmthickGalvanized
Steel Sheet (Conform to 1
MAT-01390 BMT-N.61 IS277)formedtoprovidea46mmthickfully Sqm 14530
754 flush, double skin door shell withLock
Seam joints at stile edges with
asingle/multiLayerofLeadsheetvaryingthi
cknessfrom3mm/1mmto2mmdepends
onradiationlevel,
theleadsheetsextendthefullwidthandheig
htofthedoor,Leadthicknessisequaltothes
hieldingintheadjacentwall, the door
frames and door shuttersare coated with
polyesterpowders
ofPurepolyester/epoxypolyesterorpolyur
ethane powder for powder
coatingofthickness60–
65microns,coatedwith Zinc Phosphate
Primer to
receiveanypaintonsiteorfinishedwithTher
mosettingPolyurethanepaintofAliphatic
Grade providing high levels
ofscratchresistanceanddurability,hardwa
rewithStainlessSteelBallBearingButt
Hinges 3mm thick
fixedflushtotheframeandshutteretccompl
eteforfinisheditem
Supply&FixingofLeadLinedStainlessst
eelCleanroomdoorframesandshutters
madeofStainlesssteelgradeof304hairline
finish,framewith1.60mm(16SWG)thick 1
MAT-01391 BMT-N.62 Sqm 22940
755 hairline finish Stainless steel gradeof
304 formed to Single/double
rebateprofileofsize100mmx58mm/143x5
8mm,doorframeswithasingle/multi

105
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Layer of Lead sheet varying
thicknessfrom
3mm/1mmto2mmdependsonradiation
level, the shutter with 1.2 mmthick
hairline finish Stainless steel gradeof
304 formed to provide a 46mm thickfully
flush, double skin door shell withLock
Seam joints at stile edges with
asingle/multiLayerofLeadsheetvaryingthi
cknessfrom3mm/1mmto2mm depends
onradiation level.
Theleadsheetsextendthefullwidthandhei
ght of the door. Lead thickness is tobe
equal to the shielding in the
adjacentwall.Hardwarecanbeprovidedwit
hStainless Steel Ball Bearing Butt
Hinges3 mm thick fixed flush to the
frame andshutter etc complete for
fisnihed item ofwork
MAT-01395 BMT-N.66 ITEMDELETED
756
A) Specification for Foamed PVC
DoorFrame & ABS Shutters:Providing
ofFactory made prelaminated
FPVC(Foamed Polyvinyl Chloride) Door
frameof the size 105x40mm with a
wallthicknessof10mmmadeoutofextrude
d rigid FPVC profile mitre joinedwith 6
Nos. of 50mm long screw.Thedoor
frame shall be fixed to the wall byusing
80mm long screws through
theframewiththehelpofPVCfastenersof3
no'sto be provided for each
verticalmember,GI stiffners of ("U"
chanel ofsize29x9x1mm,150mmlong)-
3no'sathinge point,Frame reinforcement
MAT-01396 BMT-N.67 of("U"GI chanel of size Each 14189
757
46x22x.06mm),Bottomtie rod of ("U" GI
chanel size of15x15x1mm) etc.
complete as permanufacturers
specification for finisheditem of
work.Maximum door framesize:980x
2070.
B)
Providing of 35mm thick Facotry
madePrelaminated ABS
(AcrolynitrileButadyneStyrene)Doorshutt
ermoulded in different designs,
consistingof all round Frame made out
of waterproof solid foam PVC bar of
size20x32mm, reinforced by 32x 32mm
- 2nos. for vertical made out of
LVL(Laminated Veneer Lumber),
corematerialof32mmthickhighdensitycraf
t paper honey comb board,sandwiched
onbothsideswithprelaminated ABS
sheetthickness of1.5mm.PVCedge
bandingofsize
106
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
0.45mmontheverticalsides.Hardwarema
de out of steel coated butterflyhinges -
3 Nos. for each shutter and ISImake
S.S round lock completes forfinished
item of work. Maximum
shuttersizeof:910x2030mm
Supply and fixing of Bath room /
Toiletdoor shutter with 16mm laminated
(IS14276)doorshutterwithall-
round‘U’lipping of PPS section of size
12mm X18mmX 12mmX0.6mm
thickness with 1
758 MAT-01398 BMT-N.69 ahardwareof12mmdiaX200mmlongalumi Sqm 2265
num aldrop – 2 nos( ISI make)2 Noof
125mm long handles(ISI make) andalso
3 noOf IS304 grade Patee
Hinges3mmX12mmX180mmlongwithpol
ereceiver of 10mm dia pole X40mm
longwelded on 2mm X40mm(ss304)
platesworks as receiver for RT patte
hinges.Thepriceinclusive ofall material
atsite
Supply and fixing of toilet door
shutterwith frame made of M.S. door
frame
of5mmX48mmX48mm(Langel)asall-
roundframetheframeiscoatedwithone
coat of red oxide and two coats
ofenamel of approved color. For
shutterandtheshutterismadewith16mmla
minatedshutterwithall- 1
759 MAT-01399 BMT-N.70 round‘U’LippingofPPSsectionof12mmX1 Sqm 3530
8mmX12mmX0.60mm,alonghardware of
200m long and 12mm diaaluminum
aldrop( ISI make)2 Nos, 2Nosof125m m
handle, 3 Nos of RT pattehinges IS
304gr
SS2mmX12mmX180mm
longwitha
polereceiverof10mmDiaX40mmbywelde
d on 3mmX40mm SS 304, plate
itworksasreceiverforRTPateehingesit is
welded to M.S. angle . M.S. anglewill be
fixed to wall of self
expandablescrewsandcaps.
Door shutter with shutter frame and
InfillpanelmadefromPVCmaterialconform
ingtoIS:10151:1982.Theshutterframeism
adeoutofPVCextrudedsectionshavingov
eralldimensions of 100mm X 30mm,
MAT-01402 BMT-N.73 with twoself extruded grooves at 40mm Sqm. 960
760 & 50mmon front surface. The Infill panel
is madeout of multi chambered
seamless
hollowPVCextrudedpanelhavingoveralldi
mensions of 610 mm X 20 mm.
Theshutterframeshallbemetercutand
107
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
joinedatcornersbymeansofplasticbracket
s. Stickers showing locations ofdifferent
hardware will be pasted on
theshutter.ALLDimensionsarein MM.
TheshutterframemadeoutofPVCextrued
esectionhavingoveralldimensions of
59mm x 24mm with wallthickness of
1.0mm +/-0.3mm with usualprocess
variation corresponding to
theSintexCodeNo.DWUF-
302.Theshutter frameis given tampered
shapeto provide better grip to the infill
panelandtodrainoutthewater.Theinfillpan
elismadeoutofseamlessonepiecemultich
MAT-01403 BMT-N.74 1 1924
amberedPVCextrudedsectionhavingover
Sqm
alldimensionof610mm x 20mm with wall
thickness of1mm+/-
0.2mmwithusualprocessvariationcorresp
ondingtotheSintexcode No.SPUF-128.
The shutter
frameshallbemitrecutandjoinedatthecorn
er polymeric “L’ Type corners shallbe
761 provided at the corners to take
uphardwares & fixtures and shall be
fixedwith19x8mmcountersunk-
fullythreadedparallelshanksteelscrews.A
llthehardwarelocationsshallbereinforced
withspecialpolymericBars.
BMT- ITEMsDELETED
762 to
N.75toBMT
765 -N.78
Providing and fixingPVC door
claddingtothe flush doors shutters. For
766 the
MAT-01338 BMT-N.09 newdoorsitshallbepastedwithFevicolSS 1sqm 350
R998ornailedtotheolddoors.complete as
per direction of Engineer –in – charge,
manufacturers specificationand drawing-
1mm thick
Providing and fixingPVC door
claddingtothe flush doors shutters . For
767 the
MAT-01339 BMT-N.10 newdoorsitshallbepastedwithFevicolSS 1sqm 375
R998ornailedtotheolddoors.complete as
per direction of Engineer –in – charge,
manufacturers specificationand drawing-
1.5mmthick
Providing and fixingPVC door
claddingtothe flush doors shutters . For
768 the
MAT-01340 BMT-N.11 newdoorsitshallbepastedwithFevicolSS 1sqm 431
R998ornailedtotheolddoors.complete as
per direction of Engineer –in – charge,
manufacturers specificationand drawing-
2.0 mmthick
BMT-N.84 Providingandfixingfactory madeuPVC
769
108
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
white colour
casement/Casementcumfixed glazed
door comprising of uPVCmulti-
chambered frame, sashandmullion
(where ever required) extrudedprofiles
duly reinforced with 1.60 ± 0.2mm thick
galvanized mild steel sectionmade from
roll formingprocess
ofrequiredlength(shape&sizeaccordingt
o Upvc profile),uPVC extruded
glazingbeadsofappropriatedimension,E
PDMgasket,zinc alloy(white powder
coated) 3D hinges andone
handleoneachside
of panels along with zinc plated
mildsteel multi
pointlockinghavingtransmissiongear,cyli
nderwith keeps and one side
key,G.Ifasteners100 x 8 mm size for
fixingframe to finished wall
andnecessarystainlesssteelscrews,etc.
Profileofframe&sashshallbemitredcuta
ndfusion
welded at all corners, mullion
(ifrequired) shall be
alsofusionweldedincludingdrillingofhol
esfor fixing hardware's and
drainageofwater etc.After fixing frame
the gapbetween frame and adjacent
finishedwallshall
be filled with weather proof
siliconsealent over backer rod of
requiredsizeand of approved quality,
allcompleteasperapproveddrawing&
directionof Engineer-in-
Chargeinclusiveof cost ofSingle /
doubleglasspanesandsiliconsealent .
Note: For uPVC frame, sash
andmullion extruded profiles
minus5%tolerance in dimension
i.e. indepth & width of profile
shall beacceptable.Variation in
profiledimension in higher side
shall
beacceptedbutnoextrapaymento
nthisaccount shallbemade.
Casement door with 3D hinges made
of(big series) frame 67x 64 mm & sash
770 67x110mmbothhavingwallthicknessof
MAT-05437 BMT-N.84.A 2.3 ± 0.2 mm and single glazing bead 1sqm 8217
/doubleglazingbeadofappropriatedimens
ion.(Areaofdoorupto2.00sqm).

Casement door with top hung


771 MAT-05438 BMT-N.84.B 1sqm 8395
ventilatorwith3DandS.S.frictionhinges(4
00x19x1.9mm)madeof(bigseries)frame

109
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
67x64mm,sash67x110mm&mullion67x8
0mmallhavingwallthickness of 2.3 ±. 0.2
mm and singleglazing bead / double
glazing bead
ofappropriatedimension.(Areaof
doorupto
2.50sqm)
Providing and fixing factory made
uPVCwhite colour sliding
glazeddoorcomprisingof uPVCmulti-
chamberedframewithin-builtrollertrack
andsash extruded profiles
dulyreinforced with 1.60 ± 0.2 mm
thickgalvanizedmild steel section made
fromroll forming process of required
length(shape & size according to
uPVCprofile), appropriate
dimensionuPVCextruded glazing beads,
uPVCextruded interlock and
uPVCextrudedInlinesashadaptor(ifrequir
ed), EPDM gasket, wool pile,
zincalloy(white powder coated) handle
withkeyononesideofextremepanelsalong
with zinc plated mild steel multipoint
locking having transmissiongearwith
keeps, zinc alloy (white powdercoated)
cresent lock
BMT-N.85 (ifrequired),stainlesssteel(SS304grade)
772
bodywithadjustable doublenylon rollers
(weightbearing capacity to be 120 kg),
G.Ifasteners 100x
8 mm size for fixing frame to
finishedwall and necessary
stainlesssteelscrewsetc.Profileofframe
&sashshall be mitred cut and fusion
weldedatallcorners,includingdrillingofho
lesforfixing hardware's and drainageof
wateretc. After fixing frame the gap
betweenframe andadjacent
finished wall shall be filled with
weatherproof silicon sealent over
backerrod
ofrequiredsizeandofapprovedquality,allc
omplete as per approveddrawing
&directionof Engineer-in-
Chargeinclusiveof cost ofSingle /
doubleglass panes,wire mesh and
siliconsealent.
Note: For uPVC frame and
sashextruded profiles minus
5%toleranceindimensioni.e.indepth
&width of profile shall be
acceptable.Variationin profile
dimension inhigher side shall be
accepted but noextra
paymentonthisaccount shallbe

110
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
made.
Two track two panels sliding door
madeof (big series) frame 67 x 50 mm &
sash46x
773 MAT-05439 BMT-N.85.A 82mmbothhavingwallthicknessof 1sqm 5404
2.3 ± 0.2 mm and single glazing bead
/doubleglazingbeadofappropriatedimens
ion.(Areaofdoorabove2.00sqmupto5.00s
qm)
Threetrackthreepanelsslidingdoorwith
fly proof S.S wiremesh (Two
nos. glazed & one no. wiremesh panels)
made of(big series) frame116 x 45 mm
774 MAT-05440 BMT-N.85.B & sash 46 x 82 mm bothhaving wall 1sqm 6996
thickness of 2.3 ± 0.2 mmand single
glazingbead/doubleglazi
ngbeadofappropriate dimension.
(Areaofdoor
above2.00sqmupto5.00sqm)
Providing and fixing of factory made
ofHighDensityHighMoistureResistantWo
odFibre(HDHMR)singleshutterDuradoor
madeupofFRAME:Doorframe
manufactured with High
DensityHighMoistureResistantWoodFibr
e(HDHMR)of36mmwidthx100mmdepth ,
laminated with 0.2mm thick PVCFoil
using hot press andPUR adhesive,fitted
with Gasket for energy efficiencyand
noise protection,affixed to the
wallusinghighstrengthexpandablePUFoa
m/self-expandablewallfixingscrews.Max
dimensions in MM of
280(depth)x2440(height)SHUTTER:Fact
775 MAT-05441 BMT-N.86 orymade41mmthickshuttersandwichedw 1sqm 11249
ithHighDensityHighMoistureResistantW
oodFibre(HDHMR) of 5.5mm thick
skinson
bothsidesandHDHMRof30mmthickness
as skeleton,core of high density
HoneyCombandLaminatedVeneerLumb
er(LVL)forholdingthelockbodyandhardw
are,laminatedwith0.2mmthickPVCFoilan
dedge-bandedwith1mmthickPVCedge-
bandusinghotpressandPURadhesives.M
axdimensionsinMMof1200(width)x41(thi
ckness)x2400(height),ARCHITRAVE:Fa
ctorymadeArchitrave of size 80mm
x12mm fittedtopre-
madegrooveswithintheframeforaddedae
sthetics.Fourdesignvariantsavailable,ma
dewithDensityHighMoistureResistantWo
od

111
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Fibre(HDHMR) of
differentthicknessesdependingonthedesi
gnvariant,laminatedwith0.2mmthickPVC
FoilusinghotpressandPURadhesive,fitte
dtothewallusingstrongquickactingadhesi
ves.
HARDWARE &ACCESSORIES:
Importedhardwareincludingdoorhandles
– 1no,cylindricalmagneticlock
-1 no ,SS hinges – 3 nos. Including
costandconveyanceofallmaterial,Hardwa
re,Labourchargesandtransportationcom
pleteforfinisheditem ofwork

SupplyandfixingofBath/ToiletDoorframe
and shutter with8mm
laminated(IS.15786)using with
50mmx35mmx1.3mmthickaluminumdoo
rframeofweight220grmperRftwith a
rebate of 30 mm for provision
forshutter,shuttermadewith45mmx25mm
x1.3mmthickaluminumsection of weight
776 MAT-05442 BMT-N.87 210grms per Rft 1sqm 4872
with8mmgroovetoaccommodate8mmthic
klaminated (IS.15786)and shutterhaving
3nos of ss 304gr Butt hinges
of100mmlong,100mmaluminumhandles
-2nos, and also 2 nos of
200mmx12mmaluminum aldrops ,the
rates inclusive
ofalllaborfixingatsiteand50micronsIvory
powder coated for aluminum doorframe
and shutter sections etc
completefinished itemofwork.
Providing and fixing28 -30 MM
thicksolidWoodPolymerComposite(WPC
)single extruded door shutter with
777 MAT-05443 BMT-N.88 3MMtop and bottom rigid layer with an 1sqm 3030
overalldensity of 750kg/Cum. It will be
fixed tothe frame using 3 inch /4 inch
hinges. Aminimum of 4 hinges will be
required forfixingthe doorwiththeframe
IV.SUB- CUP-BOARDDOORS
SECTION
SupplyandfixingofCementBondedParticl
eBoard(IS14276)cupboardframes and
shuttersand using
16mmCementBondedParticleBoardduly
778 MAT-01353 BMT-N.24 paintedbothsideswithonecoatofprimeran 1sqm 2210
dtwocoatsofsynthetic/enamelpaintofappr
ovedshadeandbrandincludingfixingofhar
dwarelike
M.S.powdercoatedPianohingesofsize18
mmx18mm,brassballcatches,

112
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Aluminumtowerboltsandhandles,Godrej
locks, Fevicol, screws and
nailsincludingcostandconveyanceofallm
aterials,laborcharges,allincidentaland
operational charges etc.,
completeforfinisheditemofworkatsiteasp
erthedirectionsof EngineerinCharge.
SupplyandfixingofCementBondedParticl
e Board (IS 14276) box type
cupboardusingCementBondedParticleB
oardfor making frame of size 100mmx
35mmusing
twosandwiched16MMboards,oneCemen
tBondedParticleBoardandoneCEMENTB
ONDEDPRE-
779 MAT-01358 BMT-N.29 LAMINATEDPARTICLEBOARDS 1 3540
withplain35mmwoodlipping.TheShutters Sqm
aremadeof16MMthickCEMENTBONDE
DPRE-LAMINATED
PARTICLEBOARDS(Pre-
LaminatedCementBondedParticleBoard)
ofapprovedshadeinclusiveofhardwarelik
e M.S. powder coated Piano hinges
ofsize ¾” x ¾” , Aluminum powder
coatedhandles of size 4” (101.6mm),
Aluminumtower bolt 4” (101.6mm)
Godrej locks,screws, wood lipping and
Fevicol etc.,completefinishitemofwork.
Supplyandfixingofcupboardshutterusing
teakwood scantling of size
50mmX50mm teakwood as outer frame
and50mm X 30 mm of sizeteakwood
forshutterframes,8mmthickBisonLamas
panelto each shutter consist of 2Nos
780 MAT-01400 BMT-N.71 75mm long tower bolt – 2 nos 75mm big 1 3710
handle the and other shutter willhave 1 Sqm
no ofcupboard lack , 1 No of 75mm long
handle and 75mm10mmX1mmthick SS
hinges- 2 Nos for each shutter.The
above frame will be fixed to the
wallwithscrews,therateinclusiveofscrews
, handle, etc., complete at site ofwork.

WINDOWS
P.SECTION (Landingcost–
includingloading,costof
conveyance,unloading)
I.SUB- OPENABLEWINDOWS
SECTION
Supply and fixing of pre-painted
steelopenable windowsbase steel as
perIS513of-
0.58mmthick'D"quality,galvanized as per
IS 277 , finish
paintedwithapolyesterpaintof12-
16microns
113
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
thick and back coated with 5-7
micronsthickalkydbacker,sectionforouter
frame of 46 x 52 mm section and
forshutterof46x46mmsectionformullion4
6x70mm,andsectionforbeading should
be 18 x 25 mmwith
5mmthickplainfloatglassfittedwithEthylpr
opyleneDiaminemonomerGasket
(EPDM)
andhandlemadeofhighgradealuminiump
owdercoatedwithframesfixedtotheconcre
te
/masonrywallbymeansofselfexpandingsc
rewsincluding10mmsquareguardbarswit
h6"pitchcompleteforfinisheditemofwork .
Windows:Singleshutter2'0x4'0(609.6x12
MAT-01409 BMT-P.01 19.2mm)Outerframesectionsizeof46x52 1sqm 5742
781
mmshutterframesectionsizeof46x 46mm

Windows: Double shutter3'-0" x 4'-


MAT-01410 BMT-P.02 0"(914.4mmx1219.2mm)outerframesecti 1 5742
782 Sqm
onsizeof46x52mmshutterframesectionsi
zeof46x 46mm
Windows:Doubleshutter3'-0"x4'-
0"(914.4mmx1219.2mm)outerframesecti 1
783 MAT-01411 BMT-P.03 onsizeof46x52mmshutterframesectionsi Sqm 6074
zeof46x46mmMullionsectionsizeof46x70
mm
Windows: Double shutter 4'-0" x 4 '-
MAT-01412 BMT-P.04 0"(1219.2x12.19.2mm)outerframesectio 1 5907
784 Sqm
nsizeof46x52mmshutterframesectionsiz
eof46x46mm
Windows: Double shutter 4'-0" x 4 '-
0"(1219.2x1219.2mm)outerframesection 1
785 MAT-01413 BMT-P.05 sizeof46x52mmshutterframesectionsize Sqm 5907
of46x46mmMullionsectionsizeof46x70m
m
Windows: Double shutter 4'-6" x 4 '-
6"(1371.6x1371.6mm) outer frame 1
786 MAT-01414 BMT-P.06 sectionsizeof46x52mmshutterframesecti Sqm 5411
onsizeof46x46mmMullionsectionsizeof4
6x 70mm
Windows:Centrefixedbothsideopenables
hutter5'-0"x4'-
0"(1524x1219.2mm)outerframesectionsi 1
787 MAT-01415 BMT-P.07 zeof46x52mmshutterframesectionsizeof Sqm 5411
46x46mmMullionsectionsizeof46x70mmf
ixedbeadingsectionsizeof18 x 25mm

Windows: Centre fixed both 1


MAT-01416 BMT-P.08 5411
788 sideopenable shutter Sqm
6'-0" x 4'-0"

114
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
(1828.8x1219.2mm) outer frame
sectionsizeof46x52mmshutterframesecti
onsizeof46x46mmMullionsectionsizeof4
6x70mmfixedbeadingsectionsizeof18
x25mm
Windows:Centrefixedbothsideopenables
hutter6'-0"x4'-6"(1828.8x1371.6mm)
outer frame 1
789 MAT-01417 BMT-P.09 sectionsizeof46x52mmshutterframesecti Sqm 5411
onsizeof46x46mmMullionsectionsizeof4
6x70mmfixedbeadingsectionsizeof18 x
25mm
ProvidingandfixingofOpenableWindows
madeofpre-paintedsteel(Base steel as
per IS 513 of 0.58 mmthick galvanized
as per IS 277 with Zincof 120 GSM),
primer coated with epoxyprimerof5-
7micronsthick,finishpainted with a
polyester paint of 12-16microns thick
and back coated with 5-7microns thick
alkyd backer and sectionfor outer frame
of 48 x 50 mm,
centremullionof48x50mm,sectionforshutt
erof48x25mmandthefixedglass beading
section should be 12 x 12mm and the
outer frame and mullions tohave rebate
for glazed shutter with a 20mm provision
for guard bars/grills andthe sections cut
to length metre joinedwith corner
bracket, centre mullion fixedwith mullion
cap, handle, stay, 2 nos. ofstainless
steel heavy duty pivot hingesprovided
per shutter and windows
fittedwith5mmthick plainfloat glass
withrubbergasketsincludingfixingthefram
esinconcrete/masonrywallbymeansofself
expandingscrews,Including 10mm
Square guard bars
with6”(152.4mm)pitchetc.,completeforfini
shed itemofwork.
SingleshutterWindow2’0”x4’0”(609.6mm
790 MAT-01424 BMT-P.16 x 1219.2mm).Outer framesection size of 1 5245
48x50mm shutter framesectionsizeof48x Sqm
25mm.
DoubleshutterWindowwithverticalmullion
3’0”x4’0”(914.4mmx1219.2mm) outer
791 MAT-01425 BMT-P.17 frame section size 1 5576
of48x50mmshutterframesectionsizeof Sqm
48 x25 mm.Mullion section size
of48x50mm.
DoubleshutterWindowwithverticalmemb 1
792 MAT-01426 BMT-P.18 5576
er4’0” x 4’0” (1219.2mm x Sqm

115
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
1219.2mm) outer frame section size
of48x50mm shutter frame section size
of48 x 25 mm and mullion section
shouldbeof48x50mm.
Centre fixed both side openable
shutterwindow 5’0”x4’0”
(1524mmx1219.2mm).Ou 1
793 MAT-01427 BMT-P.19 ter frame section sizeof Sqm 4914
48x50mm.Shutter frame section sizeof
48 x 25 mm.Mullion section size
of48x50mm. Fixed beading section
sizeof12x12mm.
Centre fixed both side openable
shutterwindow6’0”x4’0”(1828.8mmx121
9.2mm).Outer frame section sizeof 1
794 MAT-01428 BMT-P.20 48x50mm.Shutter frame section sizeof Sqm 4914
48 x 25 mm.Mullion section size
of48x50mm. Fixed beading section
sizeof12x 12mm.
Providing&FixingofOpenableWindows
with Fly-mesh made of pre-painted
steel (Base Steel as per IS
513of0.58mmthickgalvanizedasperIS
277withzincof150GSM)primercoated
with epoxy primer of 5-7
micronsthick,finishpaintedwithapolyester
paint of 12-16 microns thick and
backcoatedwith5-
7micronsthickalkydbacker and the
section forouter frameof 72 x 55mm,
centre mullion of 72 x50mm, section for
fixed glass beadingsection of 12 x 12
mm and section forshutters of 48 x 25
mm and outer frame& mullion sections
with rebate for
glazedshutters,flymeshanda20mmprovis
ionforguardbars/grillsandflymesh shutter
section of 20 x 40 mm andthe sections
cut to length metre
joinedwithcornerbracket,centremullionsfi
xedwithmullioncap,stay,handles,latch 2
Nos of heavy duty stainless
steelpivothingespershutterandpanelledw
ith 5mm thick plain float glass and
S.S.Mesh for fly mesh shutter (304
grade),fittedusingrubbergasketsincludin
gfixingthewindowsintheconcrete/masonr
y wall by means of
selfexpandingscrews,including10mmSq
uare guard bars with 6”
(152.4mm)pitch,completeforfinisheditem
ofwork
SingleshutterWindow2’0”x4’0”(609.6mm
795 MAT-01429 BMT-P.21 x 1219.2mm).Outer framesection size of 1 6956
72x50mm shutter framesectionsizeof48x Sqm
25mm.

116
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
DoubleshutterWindowwithverticalmullion
3’0”x4’0”(914.4mmx1219.2mm) outer
MAT-01430 BMT-P.22 frame section size 1 7288
796 Sqm
of72x50mmshutterframesectionsizeof
48 x25 mm.Mullionsection size
of72x50mm.
DoubleshutterWindowwithverticalmemb
er4’0”x4’0”(1219.2mmx1219.2mm) outer
MAT-01431 BMT-P.23 frame section size of72x50mm shutter 1 7288
797 Sqm
frame section size of48 x 25 mm and
mullion section shouldbeof72x50mm.

Centre fixed both side openable


shutterwindow 5’0”x4’0”
(1524mmx1219.2mm).Ou 1
MAT-01432 BMT-P.24 ter frame section sizeof Sqm 6625
798
72x50mm.Shutter frame section sizeof
48 x 25 mm.Mullion section size
of72x50mm. Fixed beading section
sizeof12x 12mm.
Centre fixed both side openable
shutterwindow6’0”x4’0”(1828.8mmx1219
.2mm).Outer frame section sizeof 1
799 MAT-01433 BMT-P.25 72x50mm.Shutter frame section sizeof Sqm 5797
48 x 25 mm.Mullion section size
of72x50mm. Fixed beading section
sizeof12x 12mm.
800 MAT-01438 BMT-P.30 ITEMDELETED
801 MAT-01439 BMT-P.31 ITEMDELETED
GalvanizedpowdercoatedCasementWin
dows with openable shutters
dulymanufacturedusingpressedsteelsect
ionsinmildsteelconformingtoIS
513ofhaving1.0mmthickandgalvanized
as per IS 277 of 120
GSMsurfacetreatmentwithpurepolyester
powder coating of 30-40 microns
thickandsectionforouterframeof60x50m
m,centreformullionof62x50mm, section
MAT-01440 BMT-P.32 1 5168
for shutter of 52 x 22mm, outer frame
Sqm
and mullions to
802
haveonesiderebateforglazedshutterofsiz
e24mmand10x10mmsquareguard bars
provided at 125 mm c/c
thesectionsassembledwithbolt&nutasse
mblywithzinc-electroplatedM-
5bolts,GIHandleofsize80mmx15mm
-1Nopershutter,2nosofstainlesssteel
heavy duty pivot hinges of size 3"of
SS304Gradeper shutter, windowpanes
with 5 mm thick plain float glassand
fixed with glass beading section
of10x12mmsizewith0.8mmthick

117
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
powdercoatedaluminium'U'channelandw
indowframesfixingtotheconcrete/masonr
y wall arrangement
withselfexpandingscrews,completeforfini
shed item of work - 1220 x 1372
orbelowsize
GalvanizedpowdercoatedCasementWin
dows with openable shutters
dulymanufacturedusingpressedsteelsect
ionsinmildsteelconformingtoIS
513ofhaving1.0mmthickandgalvanized
as per IS 277 of 120
GSMsurfacetreatmentwithpurepolyester
powder coating of 30-40 microns
thickandsectionforouterframeof60x50m
m,centreformullionof62x50mm, section
for shutter of 52 x 22mm, outer frame
and mullions to
haveonesiderebateforglazedshutterofsiz 1
803 MAT-01441 BMT-P.33 Sqm 4630
e24mmand10x10mmsquareguard bars
provided at 125 mm c/c
thesectionsassembledwithbolt&nutasse
mblywithzinc-electroplatedM-
5bolts,GIHandleofsize80mmx15mm
-1Nopershutter,2nosofstainlesssteel
heavy duty pivot hinges of size 3"of
SS304Gradeper shutter, windowpanes
with 5 mm thick plain float glassand
fixed with glass beading section
of10x12mmsizewith0.8mmthickpowderc
oatedaluminium'U'channelandwindowfra
mesfixingtotheconcrete/masonry wall
arrangement
withselfexpandingscrews,completeforfini
shed item of work - 1530 x 1372
orabovesize
GalvanizedpowdercoatedCasementWin
dowswithopenableshuttersdulymanufact
uredusingpressedsteelsectionsinmildste
elconformingtoIS
513ofhaving1.0mmthickandgalvanized
as per IS 277 of 120
GSMsurfacetreatmentwithpurepolyester
804 MAT-01442 BMT-P.34 powder coating of 30-40 microns 1 6493
thickandsectionforouterframeof88x50m Sqm
m, centre for mullion of
62x88mm,sectionforglassandfly-
proofmeshshutterof52x22mm,outerfram
e and mullions to have two sidesrebate
for glazed shutter of size 24
mmand10x10mmsquareguardbarsprovi
dedat125mmc/cthesectionsassembled
with bolt & nut assembly withzinc-
electroplatedM-5bolts,GIHandle

118
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
ofsize80mmx15mm-1Nopershutter, 2
Nos of stainless steel heavyduty pivot
hinges of size 3" of SS 304Grade per
shutter, window panes with 5mm thick
plain float glass and fixed withglass
beading section of 10x12 mm
sizewith0.8mmthickpowdercoatedalumin
ium'U'channelandfly-proofmesh of SS
304 grade fixed with 18 mmx 12 mm BT
wood beading and
windowframesfixingarrangementtotheco
ncrete/masonrywallwithselfexpanding
screws, complete for
finisheditemofwork-1220x1372
orbelowsize
GalvanizedpowdercoatedCasementWin
dows with openable shutters
dulymanufacturedusingpressedsteelsect
ionsinmildsteelconformingtoIS
513ofhaving1.0mmthickandgalvanized
as per IS 277 of 120
GSMsurfacetreatmentwithpurepolyester
powder coating of 30-40 microns
thickandsectionforouterframeof88x50m
m, centre for mullion of
62x88mm,sectionforglassandfly-
proofmeshshutterof52x22mm,outerfram
e and mullions to have two sidesrebate
805 MAT-01443 BMT-P.35 for glazed shutter of size 24 1 5969
mmand10x10mmsquareguardbarsprovid Sqm
edat125mmc/cthesectionsassembled
with bolt & nut assembly withzinc-
electroplated M-5 bolts, GI
Handleofsize80mmx15mm-
1Nopershutter, 2 Nos of stainless steel
heavyduty pivot hinges of size 3" of SS
304Grade per shutter, window panes
with 5mm thick plain float glass and
fixed withglass beading section of 10x12
mm
sizewith0.8mmthickpowdercoatedalumin
ium'U'channelandfly-proofmesh of SS
304 grade fixed with 18 mmx 12 mm BT
wood beading and
windowframesfixingarrangementtotheco
ncrete/masonrywallwithselfexpanding
screws, complete for finisheditem
ofwork-1530x1372 orabovesize
Providing&FixingofMeshwindowsmade
ofpre-
paintedsteel(BaseSteelasperIS513of0.5
806 MAT-01444 BMT-P.36 8mmthickgalvanizedasperIS277withzinc 1 4333
of Sqm
120GSM),primercoatedwithepoxyprimer
of5-7micronsthick,finishpainted with a
polyester paint of 12-
16micronsthickandbackcoatedwith5-7

119
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
microns thick alkyd backer, section
forouterframeof47x36mm,centremullion
of 60 x 36 mm,section
meshbeading18x6mmandFlymeshshutt
ersectionof20x40mm,thesections cut to
length meter joined withcorner bracket
and centre mullions fixedwith mullion
cap,handles, latch, 2
Nosofheavydutystainlesssteelpivothinge
sperS.S.Meshforflymeshshutter (304
grade) including fixing theframes in the
concrete/masonry wall
bymeansofselfexpandingscrewscomplet
eforfinished itemofwork.
ProvidingandfixingofOpenable/Caseme
ntWindowsmadeofpre-painted steel
(Base steel as per IS
513of0.80mmthickgalvanizedasperIS
277withZincof120GSM),finishpainted
with a polyester paint of 60-
65micronsthickandsectionforouterframe
of 80 x 45 mm, centre mullion of80 x 60
mm, section for shutter of 52 x25 mm x
0.6 mm thick, outer frame
andmullionstohaverebateforglazedshutte
rwithaprovisionforguardbars/grills and
the sections cut to lengthmetre joined
with corner bracket, centremullion fixed
with mullion cap, 1 No. ofHigh grade
nylon latch handle,
windowstopper,2nos.ofwithMSPowderco
ated/SSballbearingbuttHingesprovided
per shutter and windows
fittedwith4mmthick plainfloat glass
withrubbergasketsincludingfixingthefram
esinconcrete/masonrywallbymeansofself
expandingscrews,Including 10 mm
Square guard bars
with6”(152.4mm)pitchetc.,completeforfini
shed itemofwork.
Single openable shutter window size
of2’ 0” x 4’ 0” (609.6 x 1219.2mm)
807 MAT-01454 BMT-P.46 outerframesectionsizeof80x45mm,shutt 1sqm 4625
er frame section size of 52 x 25mmthick

Double openable shutter window Size


of3’0”x4’0”(914.4mmx1219.2mm)
808 MAT-01455 BMT-P.47 outerframesectionsizeof80x45mm,shutt 1sqm 4917
er frame section size of 52 x25mm,
vertical mullion section size of 80x60mm

Doubleopenableshutterwindowsizeof4’0”
809 MAT-01456 BMT-P.48 1sqm 4917
x4’0”(1219.2mmx1219.2mm)

120
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
outerframesectionsize80x45mm,shutterf
ramesectionsizeof52x25mm ,Vertical
mullion section size of 80 x60mm

DoubleOpenableShutterandCenterFixed
window of size 5’0 x 4’0 ( 1524
x1219.2mm)outerframesectionsizeof80
810 MAT-01457 BMT-P.49 mmx45mm,shutterframesectionsizeof52 1sqm 4333
x25mm,Verticalmullionsectionsizeof80x
60mm,beadingsection size of 9 x
12mmto be providedforglass holding

DoubleOpenableShutterandCenterFixed
window of size 6’0 x4’0 ( 1829.6
x1219.2mm)outerframesectionsizeof80
811 MAT-01458 BMT-P.50 mm x 45mm , shutter frame 1sqm 4333
sectionsizeof52x25mm,Verticalmullionse
ctionsizeof80x60mm,beadingsection
size of 9 x 12mmto be providedforglass
holding
Note:Theabove rates are
fornormalfinish,10%extramaybeallowedf
orWoodGrainfinish
ProvidingandfixingofOpenable/Casemen
t Windows with fly mesh madeof pre-
painted steel (Base steel asperIS 513 of
0.80 mm thick galvanized asper IS 277
with Zinc of 120 GSM), finishpainted
with a polyester paint of 60-
65micronsthickandsectionforouterframe
of 100 x 45 mm, centre mullion of100 x
60 mm, section for shutter of 52 x25 mm
x 0.6 mm thick, section for fly-shutter of
52 x 25 mm x 0.6 mm thickand fitted
with stainless steel 32 gaugefly mesh of
304grade with 144holesper sq.inch and
mullions to have doublerebate for glazed
shutter and fly-shutterwith a provision for
guard bars/grills andthe sections cut to
length metre joinedwith corner bracket,
centre mullion fixedwith mullion cap, 1
No. of High gradenylonlatchhandle,
window stopper, 2nos. of with MS
Powder coated /SS ballbearing butt
Hinges provided per shutterand
windows fitted with 4 mm thick plainfloat
glass with rubber gaskets
includingfixingtheframesinconcrete/mas
onrywallbymeansofselfexpandingscrews
, Including 10 mm Square
guardbarswith6”(152.4mm)pitchetc.,com
pleteforfinished itemofwork.

121
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Single openable shutter window size
of2’ 0” x 4’ 0” (609.6 x 1219.2mm)
812 MAT-01459 BMT-P.51 outerframe Double rebate section size 1sqm 6135
of100x45mm,Glazedandflymeshshutterp
rofilesectionsizeof 52x25mm
Double openable shutter window Size
of3’0”x4’0”(914.4mmx1219.2mm)
outer frame Double rebate section
813 MAT-01460 BMT-P.52 sizeof100x45mm,Glazedandflymeshshu 1sqm 6426
tterprofilesectionsizeof52x25mm,vertical
mullionsectionsizeof100x 60mm

Double openable shutter window size


of4’0”x4’0”(1219.2mmx1219.2mm)
outer frame Double rebate section
814 MAT-01461 BMT-P.53 sizeof100x45mm,Glazedandflymeshshu 1sqm 6426
tterprofilesectionsizeof52x25mm,vertical
mullionsectionsizeof100x 60mm

DoubleOpenableShutterandCenterFixed
window of size 5’0 x 4’0 ( 1524
x1219.2mm)outerframesectionsizeof80
MAT-01462 BMT-P.54 mm x 45mm , shutter frame 1sqm 5843
815
sectionsizeof52x25mm,Verticalmullionse
ction size of 100 x 60 mm ,
beadingsection size of 9 x 12mmto be
providedforglass holding
DoubleOpenableShutterandCenterFixed
window of size 6’0 x4’0 ( 1829.6
x1219.2mm)outerframesectionsizeof80
MAT-01463 BMT-P.55 mm x 45mm , shutter frame 1sqm 5843
816
sectionsizeof52x25mm,Verticalmullionse
ction size of 100 x 60 mm ,
beadingsection size of 9 x 12mmto be
providedforglass holding
Note:Theabove rates are
fornormalfinish,10%extramaybeallowedf
orWoodGrainfinish
817 MAT-01481 BMT-P.73 ITEMDELETED
SupplyingandfixingofWINDOWSwithPr
e laminatedCement BondedParticle
boards and Pre-Painted
SteelSections(PPS)fabricated from pre-
painted Cold rolled formed
sectionsmade of galvanized steelcolor
coatedsections (Basesteelas per IS-
512 Dquality, galvanized as per IS-277
withZinc of 120 gram/sqm) with total
coatedthicknessof0.58mmprimercoated
withepoxy primer of 5-7
micronsthick,finishpaintedwithpolyester
paintof

122
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
12-16
micronsandbackcoatedwithalkydbacker
of5-7microns), sectionsfor outer frame
and centre mullion (dulyfilled with PU
form of 40 kg/Cum) of60mm x 50mm,
with provision for fixingglazed shutter
and the section forglazed/paneled of
size 48 mm x 25 mmand another
section of size 60 mm x 23mm provided
for separating glazed
andpaneledportion,thesectioncuttolengt
h andmiter jointedwithplasticcorner
brackets andwithcornerbrackets for
window outer frames of50mm x 60mm,
the mullion section fixedto the frame
with plastic mullion cap andstiffener
plates of size 60 mm x 50 mmmade
of1.25mm thick CRCAelectroplated
provided to fix windowframes to
concrete/masonry, gasket forfixing glass
and 10mm both sides pre-laminated
cement bonded particle boardand 5 mm
thick color pin headed glassprovided for
glazing and providing guardbars of 10
mm square rods duly weldedat 150 mm
pitch to MS flat section ofsize 18 mm
and 3 mm thick, and fixed towall by
means of self expansion nylonCap (75)
and electroplated woodenscrews of size
100 mm, togetherwithaluminum powder
coated fittings, A)75mm long grip
handles 1 no pershutter, B) 75 mm long
tower bolts
2nos.pershutter,C)HeavydutySSPivothin
ges2no’spershutter,D)MSPowder
coated telescopic stay 1 no pershutter.
Pre Laminated Cement Bonded
ParticleBoardWINDOWS– 1
818 MAT-01484 BMT-P.76-A Singleshutter2’0”x4’0”outerframesection Sqm 5237
sizeof50mmx60mm shutter frame
sectionsizeof48mmx 25mm.
Pre Laminated Cement Bonded
ParticleBoardWINDOWS –Double
819 MAT-01485 BMT-P.76-B shutter 3’0”x4’0” outer frame section 1 5287
size of Sqm
50mmx60mmshutterframesectionsizeof
48mmx25mmmullionsectionsizeof50mm
x 60mmforouterframe.
Pre Laminated Cement Bonded
ParticleBoard WINDOWS – Double
820 MAT-01486 BMT-P.76-C shutter 3’0”x3’0” outer frame section 1 5499
size of Sqm
50mmx60mmshutterframesectionsizeof
48mmx25mmMullionsectionsizeof50mm
x 60mmforouterframe.

123
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Pre Laminated Cement Bonded
ParticleBoardWINDOWS–
821 MAT-01487 BMT-P.76-D Doubleshutter4’0”x4’0”outerframesectio 1 5086
nsizeof50mmx60mm shutter frame Sqm
sectionsize of 48mm x 25mm Mullion
sectionsizeof50mm x 60mmforouter
frame.
II.SUB- SLIDINGWINDOWS
SECTION
Providing and fixing Pre painted
SteelslidingWindow/Doorfabricatedfro
mroll formed sections made of
Galvanizedsteelcolourcoated/powderco
ated(BaseSteelasperIS513‘D’qualitygalv
anizedasperIS277withZincof
120Gms./Sq.mtr)withtotalcoatedthicknes
s of 0.58mm. Primer Coat
withepoxyprimerof5-
7micronsthick,finished paint with a
polyester paint of12-
16micronsthickandbackcoatedwithAlkyd
backerof5-
7micronsorpowdercoatedwithpurepolyes
terpowderupto50-
60micronsthick.TheExternalSectionfortw
otrackSliding Window should be of 44 x
59mmwith a provision for bottom track
insertprofile of 10x9 mm made of
822 MAT-01434 BMT-P.26 aluminium.Section for Window glass 1 6166
shutter Sqm
shouldbeof35x49mm,SectionforWindow
Eurogrooveshouldbeof25x24mmmadeof
plastictoaccommodatestandardaccessor
ies,andsectionforwindow lap strip should
be of 21x4mmmade of
plastic.SectionforDoo
rshuttershouldbeof35x67mm,Sectionfor
DoorEuroGroove25x31mmmadeofplasti
ctoaccommodate standard accessories
andsize of lap strip should be of
39x41mm.The
Window/Doortobepanelled with5mm
thick plain float glass. The
gasketsaretobemadeofEthylPropyleneDi
amineManomer[EPDM].CornerBrackets
for internal and external frameto be
made of glass filled nylon. Touchlock to
be provided for Window
Shutter.Sections are to be cut to length,
joinedandassembledbymeansofcornerbr
ackets. The above frame to be fixed
toBrick/Concrete masonry by using
Nylonself-
expandingcapsanddrivingMSelectroplat
ed80mmscrewsintothecaps through
frames. The Grill for safetyfor windows
to be made of 10mm
thicksquarerodbarswith152mmpitchfor
124
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
complete item of work .For Door
therewill be no Safety Grill including cost
andconveyanceofallmaterials,accessorie
s,labourchargesfortransportation,
erection at site
completeforfinisheditemofwork.
823 MAT-01435 BMT-P.27 ITEMDELETED
824 MAT-01436 BMT-P.28 ITEMDELETED
825 MAT-01437 BMT-P.29 ITEMDELETED
ProvidingandfixingCOMPOSITESLIDIN
G WINDOW fabricated from
rollformedsectionsmadeofGalvanizedSte
elcolourCoated/PowderCoated(Base
Steel as per IS 513 “D”
quality,GalvanizedasperIS277withZincof
120grams/Sq.Mtr.)withtotalcoatedthickn
essof0.58mm,powdercoatedwith pure
Polyester Powder up to 50-
60micronsthickandthesectionforexternalf
ramebottomof68x25mm(Aluminium),
External frame sides & Topof 68 x 25
mm (Aluminium), section
826 MAT-01445 BMT-P.37 forshutterof59x23mmandLapStripof30 x 1 5411
7.5mm (uPVC) cut to length andmitre Sqm
joined withL-bracket and 5
mmplainfloatGalsswithEthylPropyleneDi
amine Monomer (EPDM) gasket,
thecorner bracket for external frame
madeof Aluminium ‘L’-Angle, Corner
Bracketfor internal frame made of
Polyproylene,CrescentLatch,Rollers,&E
PDMGaskets for shutters, wool pile for
lapstrip,BumpStopBase&Rubberforshutt
erstopperincludingfixingtobrick/concrete
masonryusingNylonself-
expandingcapsanddrivingMSelectroplate
d 80mm long screws into thecaps
through frames and fixing 10mmsquare
guard bars with 6” pitch centre tocentre
(152.4mm) completed for finisheditem
ofwork
ProvidingandfixingofTwoshutterSliding
Windows made of
GalvanizedSteel(BaseSteelasperIS513,
Dquality, galvanized as per IS 277
withZinc of 120 GSM), using factory
madesectionpowdercoatedwithPurepoly
esterpowderupto50-60micronsthick with
total coated thickness of
0.58mmforOuterFrameand0.58mmthick
ness for Sliding Shutter Section,
theOuterFrameforTwoTrackswithGrill

125
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
provision size of 90 mm x 50 mm
andwithout grill provision is of 75 mm x
50mmandtheWindowShuttersectionof
0.58 mm x 36 mm and the outer
Framewithtwointegratedguidetracksof12
mmwidthand24mmdeepforprovisiontosli
detheShutter/sashframe and facilitates
with a water drainoutlet component
made of PVC and theshutter frame fitted
with 5mm thick
plainfloatglassofreputedmakeandfixedwi
thEPDMweatheringsealresistantaccesso
riesandhandlemadeofAlumimium 1 No.
per each shutter
andcuttolengthmiterjoinedwithcornerbra
ckets including installation of
windowsystem at site using anchor
fasteners,SiliconsealantappliedattheOut
erframecornersinclusiveofconveyanceof
allmaterialsaccessories,labourcharges,a
nderectionatsitewithcompletefinishedite
mofwork.
a)WindowwithTwoSlidingShuttersand
827 MAT-01446 BMT-P.38 1 5411
without Grill Outer Frame Size 75mmx
Sqm
50 mm.
b)WindowwithTwoSlidingShuttersandwit
hGrillOuterFrameSize90mmx 50 mm
have a rebate of 15mm x 5 1
828 MAT-01447 BMT-P.39 mmtofitgrillmadeof10mmMSSqRodsfor Sqm 5647
horizontal barswelded at a regularpitch
of 150mm to 12mm x 6mm MSflat.

ProvidingandfixingofThreeshutterSlidin
g Windows made of
GalvanizedSteel(BaseSteelasperIS513,
Dquality, galvanized as per IS 277
withZinc of 120 GSM), using factory
madesectionpowdercoatedwithPurepoly
esterpowderupto50-60micronsthick with
total coated thickness of
0.58mmforOuterFrameand0.58mmthick
ness for Sliding Shutter Section,
theOuter Frame for three tracks with
grillprovision size of 105 mm x 50 mm
andwithout grill provision is of 90 mm x
50mm and the Window Shutter section
of58 mm x 36 mm and the outer
Framewithtwointegratedguidetracksof12
mmwidthand24mmdeepforprovisiontosli
detheShutter/sashframe and facilitates
with a water drainoutlet component
made of PVC and
theshutterframefittedwith5mmthickplain

126
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
floatglassofreputedmakeandfixedwithEP
DMweatheringsealresistantaccessoriesa
ndhandlemadeofAlumimium 1 No. per
each shutter
andcuttolengthmiterjoinedwithcornerbra
ckets including installation of
windowsystem at site using anchor
fasteners,SiliconsealantappliedattheOut
erframecornersinclusiveofconveyanceof
allmaterialsaccessories,labourcharges,a
nderectionatsitewithcompletefinishedite
mofwork.
Windowwith3shutters(centerfixedshutter
/ Center sliding shutter / centerFly mesh
shutter) and with Grill Windowmade of
Outer Frame of Size 105 mm x50
mm.Grill made of 10mm MS
SquareRodsforhorizontalbarsataregular
pitchof150mmweldedtoMSflatof12x6mm
.
i) Center Shutter Fixed:center
shutterframe made of section with size
20mm x47mm should be fitted with 5mm
thickplain float glass of reputed make, 1
829 MAT-01448 BMT-P.40 Sqm 5647
EPDMgasket all around the glass and
fixed
totheOuterFramewiththesupportingsecti
onofsize29mmx20mmof0.58mm thick
fixed horizontally on topand
bottomoftheshutterframe.
ii) Center Shutter Sliding:center
shutterframe made of section of size
20mm x47mmshouldbefittedwith 5
mmthick plain float glass of reputed
830 MAT-01449 BMT-P.41 make.Thesupportingguidesectionofsize1 1 6183
5mmx19mmof0.58mmthickfixedhorizont Sqm
ally at top and bottom of shutterframe
and slides along the bottom andtop
guide tracks made of sections
size24mmx20mmof0.58mmthickand29m
mx 20mm of0.58mmthick
iii)CenterFlymeshShutterSliding:Sectionf
orFlymeshShutterframeshouldbeofsize2
0mmx40mmof0.58mm thick and fitted
with SS
mesh(304Grade).Thesupportingguidese
831 MAT-01450 BMT-P.42 ctionofsize29mmx20mmof0.58mm thick 1 6183
at the bottom and 15mm x19mm of Sqm
0.58mm thick at the top fixedhorizontally
to the Fly mesh frame andslides along
the bottom and top guidetracks made of
sectionssize 20mm x20mm of 0.58mm
and 29mm x 20mm of0.58mm.

127
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Window with 3 shutters (Center
fixedshutter / Center sliding shutter /
centerFlymeshshutter)andwithoutGrillWi
ndow made of Outer Frame of
size90mmx 50mm.
i)Center Shutter Fixed:center
shutterframe made of section with size
20mm x47mm of 0.58mm thick should
be
832 MAT-01451 BMT-P.43 1 5064
fittedwith5mmthickplainfloatglassofreput
Sqm
ed make, EPDM gasket all aroundthe
glass and fixed to the Outer
Framewiththesupportingsectionofsize29
mmx20mmof0.58mmthickfixedhorizontal
lyontopandbottomoftheshutterframe.
ii) Center Shutter Sliding:center
shutterframe made of section with size
20mm x47mm of 0.58mm thick should
be
fittedwith5mmthickplainfloatglassofreput 1
833 MAT-01452 BMT-P.44 edmake.Thesupportingguidesectionofsiz Sqm 5541
e15mmx19mmof0.58mmthickfixedhorizo
ntallyattopand bottom of shutter frame
and slidesalong the bottom and top
guide tracksmade of sections size
24mm x 20mm
of0.58mmthickand29mmx20mmof0.58m
mthick.
iii)CenterFlymeshShutterSliding:Sectionf
orFlymeshshutterframeshould be of size
20mm x 40mm andfitted with SS mesh
(304 Grade). Thesupporting guide
section of size 29mm 1
834 MAT-01453 BMT-P.45 x20mmof0.58mmthickatthebottomand Sqm 5541
15mm x 19mm of 0.58mm thick atthe
top fixed horizontally to the Fly
meshframe and slides along the bottom
andtop guide tracks made of sections
size20mmx20mmof0.58mmthickand29m
mx 20mm of0.58mmthick.
835to BMT-P.70 ITEMDELETED
837 toP.72
ProvidingandfixingfactorymadeuPVCwh
ite colour
casement/casementcumfixedglazed
windowscomprising ofuPVC multi-
838 BMT-P.78 chambered frame,sash andmullion
(where ever required)
extrudedprofilesduly reinforced
with 1.60±0.2mm thick
galvanizedmildsteel section made from
rollformingprocess of required length
(shape & sizeaccording to
uPVCprofile),uPVCextrudedglazingbead
sofappropriate

128
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
dimension, EPDMgasket, stainless
steel(SS304grade)frictionhinges,zincallo
y(white
powder coated) casement handles,
G.Ifasteners 100 x 8 mm size
forfixingframe to finished wall, plastic
packers,plastic caps and
necessarystainlesssteelscrewsetc.Profil
eofframe&sashshall bemitredcut
andfusionweldedatallcorners,mullion(if
required) shall be also
fusionweldedincluding drilling of holes
for
fixinghardware'sanddrainageofwateretc.
After fixing frame the gap
betweenframeandadjacentfinishedwalls
hallbefilled with weather proof silicon
sealantoverbackerrodof
requiredsizeandofapprovedquality,allco
mplete as per approveddrawing
&directionofEngineer-in-
ChargeinclusiveofcostofSingle/doublegl
asspanesand siliconsealant.
Note: For uPVC frame, sash
andmullionextrudedprofiles
minus5%toleranceindimensioni.e.ind
epth& width of profile shall
beacceptable.Variation in
profiledimension in higher side shall
beacceptedbutnoextrapaymentonthis
account shallbemade.
Casement window double panels
withtop fixed with S.S. frictionhinges
(350 x19 x 1.9 mm) made of (small
839 MAT-05444 BMT-P.78.A series)frame47 x 50mm, sash 47 x 68 Sqm 6283.00
mm &mullion 47 x 68 mm allhaving
wallthickness of 1.9 ± 0.2 mm and
singleglazingbeadofappropriatedimens
ion.(Area ofwindowupto 2.50sqm).
Casementcumfixedpanelwindowhaving
both end
singlecasementpanel,middlefi
xedpanelsand at top
completelyfixed ventilator
840 MAT-05445 BMT-P.78.B with S.S friction Sqm 6517.00
hinges(350x19x1.9)madeof(bigseries)
frame 67 x 60 mm , sash 67 x 80
mm&mullion67x80mmallhavingwallthick
nessof2.3±0.2mmandsingleglazingbead/
doubleglazingbeadofappropriatedimensi
on. (Area of windowabove 3.00 sqm
upto 5.00sqm).
ProvidingandfixingfactorymadeuPVCwh
MAT-05446 BMT-P.79 ite colour fixed glazedwindows
/Ventilatorscomprisingof uPVCmulti-

129
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
chambered frame andmullion
(whereever required) extruded profiles
dulyreinforced with 1.60± 0.2 mm
thickgalvanizedmildsteelsectionmadefro
mrollforming
processofrequiredlength(shape&sizeacc
ording to uPVC profile),uPVCextruded
glazing beads of appropriatedimension,
EPDM gasket,G.I fasteners100 x 8 mm
size for fixing frame
tofinishedwall,plasticpackers,plasticcaps
and necessary stainless
steelscrewsetc.Profile
of frame shall be mitred cut and
fusionwelded at all corners,
mullion(ifrequired) shall be also fusion
weldedincluding drilling of holes
forfixinghardware's and drainage of
wateretc. After fixing frame the gap
betweenframe and adjacent finished
wall shallbe filled with weather
proofsiliconsealant over backer rod
ofrequired size and of approved
quality,allcompleteasperapproveddrawi
ng &direction of Engineer-in-
Chargeinclusive ofcost ofSingle /
doubleglasspanesandsiliconsealant.
Note:ForuPVCframe,sashandmullionextr
uded profiles minus 5%tolerance
indimension i.e. in depth & width of
profileshall be acceptable.Variation in
profiledimension in higher side shall
beacceptedbut no extra payment on
thisaccountshallbemade.
Fixed windows / Ventilatorsmade
of(smallseries)frame47x50mm&mullion 1
841 47 x 68 mm both having Sqm 5830.00
wallthicknessof1.9±0.2mmandsingleglaz
ingbeadofappropriatedimension.
Providing and fixing factory made
uPVCwhitecoloursliding
glazedwindowupto1.50minheightdimen
sioncomprising of uPVC multi-
chamberedframe with in-built roller
trackand sash extruded profiles
842 BMT-P.80 dulyreinforced
with 1.60±0.2mm thick
galvanizedmildsteel section made from
rollformingprocess of required length
(shape & sizeaccording to uPVCprofile),
appropriatedimension of uPVC extruded
glazingbeads anduPVC extruded
interlocks,EPDMgasket,woolpile,zincallo
y(white

130
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
powder coated) touch locks with
hook,zinc alloy body with single
nylonrollers(weightbearingcapacitytob
e40kg),
G.Ifasteners
100x8mmsizeforfixingframe to finished
wall and necessarystainless steel
screwsetc. Profile offrame & sash
shall be mitred cut andfusion welded
atall
corners, including drilling of holes
forfixing hardware's and drainage
ofwateretc. After fixing frame the gap
betweenframeandadjacentfinishedwalls
hallbefilled with weather proof silicon
sealentover backer rod ofrequired size
and ofapproved quality, all complete as
perapproveddrawing
& direction of Engineer-in-
ChargeinclusiveofcostofSingle/doublegl
asspanes, wiremesh and silicon sealent
.Note: For uPVC frame and
sashextruded profiles minus
5%tolerancein dimension i.e. in depth
&width of profile shall
beacceptable.Variation in
profiledimension in higher side shall
beacceptedbutnoextrapaymentonthis
account shallbemade.
Twotracktwopanelsslidingwindowmade
of (small
series)frame 52 x 44 mm
843 MAT-05447 BMT-P.80.A &sash 32 x 60 mmboth 1 6038.00
having Sqm
wallthicknessof1.9±0.2mmandsingle
glazing bead
ofappropriate dimension.
(Area of windowupto 1.75sqm)
Three track three panels sliding
windowwith fly proof
SSwire mesh (Two nos.
glazed & one no.wire mesh 1
844 MAT-05448 BMT-P.80.B Sqm 8058.00
panels)madeof (small
series)frame92 x44mm & sash 32 x 60
mmboth having wallthickness of 1.9 ±
0.2 mm and
singleglazingbeadofappropriatedimensio
n(Areaofwindowupto1.75 sqm).
Twotracktwopanelsslidingwindowmade
of (big
series)frame 67 x 50 mm &
sash 46 x 62 mmboth having 1
845 MAT-05449 BMT-P.80.C Sqm 6220.00
wallthickness of 2.3 ±
0.2 mm and singleglazing bead
/ doubleglazing bead of
appropriate dimension .(Area
of window
above 1.75 sqm
131
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
upto2.50sqm).
ProvidingandfixingfactorymadeuPVCwh
ite colour sliding glazed windowabove
1.50 m in height dimensioncomprising
of uPVC multi-chamberedframe with in-
built roller track and sashextruded
profilesdulyreinforced
with 1.60±0.2mm thick
galvanizedmildsteel section made from
rollformingprocess of required length
(shape & sizeaccording to uPVCprofile),
appropriatedimension of uPVC extruded
glazingbeads, uPVCextruded interlocks
anduPVC extruded Inline sash adaptor
(ifrequired),
EPDMgasket,woolpile,zincalloy(white
powder coated) handle ononeside of
extreme panel along with zincplated
mild steel multi pointlockinghaving
transmission gear with keeps,zinc alloy
(white powdercoated) touchlock with
hook (if required for wire meshpanel),
stainlesssteel (SS 304
846 MAT-05450 BMT-P.81 grade)bodywithadjustabledoublenylonrol 1 6174.00
lers(weightbearingcapacitytobe120kg), Sqm
G.I fasteners 100 x 8 mm size
forfixingframe to finished wall
andnecessarystainlesssteelscrewsetc.
Profileof frame & sash shall be
mitredcut and fusion welded at
allcorners,including drilling of holes
forfixinghardware'sanddrainageofwater
etc.
After fixing frame the gap
betweenframeandadjacentfinishedwalls
hallbefilled with weather proof silicon
sealentover backer rod of requiredsize
and ofapproved quality, all complete as
perapproveddrawing&
directionof Engineer-in-
ChargeinclusiveofcostofSingle/doublegl
asspanes, wire meshand silicon sealent
.Two track two panels sliding
windowmade of (big series)frame 67 x
50 mm& sash 46 x 62 mm both having
wallthickness of 2.3 ± 0.2 mm and
singleglazing bead/double
glazingbeadofappropriatedimension.(A
reaof windowabove2.50 sqmupto
4.00sqm.)
Note: For uPVC frame and
sashextruded profiles minus
5%toleranceindimensioni.e.indepth
&widthofprofileshallbe

132
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
acceptable.Variation in
profiledimensioninhighersidesha
llbeaccepted
butnoextrapaymentonthisaccountsh
allbemade.
III.SUB- VENTILLATORS
SECTION
ProvidingandfixingoftophungVentilator
smadeofpre-paintedsteel(Base steel as
per IS 513 of 0.80 mmthick galvanized
as per IS 277 with
Zincof120GSM),finishpaintedwithapolye
sterpaintof60-65micronsthickand section
for outer frame of 80 x
45mm,centremullionof80x60mm,section
for shutter of 52 x 25 mm x 0.6mm thick,
outer frame and mullions
tohaverebateforglazedshutterwithaprovi
sionforguardbars/grillsandthesections
cut to length metre joined withcorner
bracket, centre mullion fixed withmullion
cap, 1 No. of High grade nylonlatch
handle, window stopper, 2 nos. ofwith
MS Powder coated /SS ball
bearingbuttHingesprovidedpershutteran
dwindowsfittedwith4mmthickplainfloat
glass with rubber gaskets
includingfixingtheframesinconcrete/mas
onrywallbymeansofselfexpandingscrews
, Including 10 mm Square
guardbarswith6”(152.4mm)pitchetc.,com
pleteforfinished itemofwork.
Single openable ventilator shuttersizeof
2’ 0” x 2’ 0” (609.6 x 609.6mm)
847 MAT-01464 BMT-P.56 outerframesectionsizeof80x45mm,shutt 1sqm 5550
er frame section size of 52 x 25mmthick

Double openable ventilator


shutterSizeof4’0”x2’0”(1219.2mmx609.6
848 MAT-01465 BMT-P.57 mm) 1sqm 5550
outerframesectionsizeof80x45mm,shutt
er frame section size of 52 x25mm,
vertical mullion section size of 80x60mm
Double openable fix shuttersize of
4’0”x3’0”(1219.2mmx914.4mm)outerfra
849 MAT-01466 BMT-P.58 mesectionsizeof80x45mm,shutterframes 1sqm 5550
ectionsizeof52x25mm ,Vertical mullion
section size of 80 x60mm

Single fixed Louvers Ventilator size


850 MAT-01467 BMT-P.59 of2’ 0” x 2’ 0” (609.6 x 609.6mm) 1sqm 3797
outerframeboxsectionsize of80x45mm

133
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Double fixed Louvers ventilatorSize
of4’0”x2’0”(1219.2mmx609.6mm)
851 MAT-01468 BMT-P.60 outerframeboxsectionsizeof80x45mm, 1sqm 3797
vertical mullion section size of 80x60mm

Double fixed Louvers Ventilatorsize


of4’0” x 3’0” (1219.2mm x 914.4mm)
852 MAT-01469 BMT-P.61 outerframe box section size of 80 x 1sqm 3797
45mm ,Vertical mullion section size of
80 x 60mm
Note:Theabove rates are
fornormalfinish,10%extramaybeallowedf
orWoodGrainfinish
ProvidingandfixingoftophungVentilator
with fly mesh made of pre-painted steel
(Base steel as per IS
513of0.80mmthickgalvanizedasperIS
277withZincof120GSM),finishpainted
with a polyester paint of 60-
65micronsthickandsectionforouterframe
of 100 x 45 mm, centre mullion of100 x
60 mm, section for shutter of 52 x25 mm
x 0.6 mm thick, section for fly-shutter of
52 x 25 mm x 0.6 mm thickand fitted
with stainless steel 32 gaugefly mesh of
304grade with 144holesper sq.inch and
mullions to have doublerebate for glazed
shutter and fly-shutterwith a provision for
guard bars/grills andthe sections cut to
length metre joinedwith corner bracket,
centre mullion fixedwith mullion cap, 1
No. of High gradenylon latch handle,
window stopper, 2nos. of with MS
Powder coated /SS ballbearing butt
Hinges provided per shutterand
windows fitted with 4 mm thick plainfloat
glass with rubber gaskets
includingfixingtheframesinconcrete/mas
onrywallbymeansofselfexpandingscrews
, Including 10 mm Square
guardbarswith6”(152.4mm)pitchetc.,com
pleteforfinished itemofwork.
Singleopenableventilatorshutterwindow
size of 2’ 0” x 2’ 0” (609.6
853 MAT-01470 BMT-P.62 x609.6mm)outer framesectionsizeof 1sqm 6865
100x45mm,Glazedandflymeshshutter
frame section size of 52 x 25mmthick

Doubleopenableventilatorshutterwindow
854 MAT-01471 BMT-P.63 Sizeof 4’ 0” x 2’ 0” 1sqm 6865
(1219.2mmx609.6mm)outerframesectio
nsizeof
100 x 45mm, Glazed and flymesh

134
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
shutterframesectionsizeof52x25mm,verti
calmullionsectionsizeof100x 60mm

Double openable fix shutter window


sizeof4’0”x3’0”(1219.2mmx914.4mm)
855 MAT-01472 BMT-P.64 outer frame section size 100 x 45mm 1sqm 6865
,Glazedandflymeshshutterframesections
ize52x25mm,Verticalmullionsectionsizeo
f 100x60mm
Single fixed Louvers Ventilator
windowsize of 2’ 0” x 2’ 0” (609.6 x
856 MAT-01473 BMT-P.65 609.6mm)outer frame box section size 1sqm 4625
of100
x45mm,flymeshshutterframesectionsize
52x 25mm
Double fixed Louvers ventilator
windowSizeof4’0”x2’0”(1219.2mmx609.
857 MAT-01474 BMT-P.66 6mm) outer frame box section sizeof 1sqm 4625
100 x 45mm, flymesh shutter
framesection size 52 x 25 mm, vertical
mullionsectionsizeof 100x60 mm
Double fixed Louvers Ventilator
windowsizeof4’0”x3’0”(1219.2mmx914.4
858 MAT-01475 BMT-P.67 mm)outerframeboxsectionsize 1sqm 4625
100x45mm,flymeshshutterframesection
size 52 x 25 mm Vertical
mullionsectionsizeof 100x60 mm
Note:Theabove rates are
fornormalfinish,10%extramaybeallowedf
orWoodGrainfinish
SupplyingandfixingofTopHungVentilator
s made of pre - painted steel(base steel
as per IS 513 of -0.58
mmthick'D"quality,galvanizedasperIS
277withzincof120GSM)primercoated
with epoxy primer of 5-7
micronsthick,finishpaintedwithapolyester
paint of 12-16 microns thick and
backcoatedwith5-
7micronsthickalkydbacker,sectionforout
erframeof46x52 mm section and for
shutter of 46 x
46mmsectionformullion46x70mm,TheVe
ntilatortobepanelled4mmpinheadglasswi
thEthylpropyleneDiamine monomer
Gasket (EPDM) andthe sections cut to
length mitre joinedwith corner brocket
mullions fixed
usingmullioncapandwithhandlemadeofhi
ghgradealuminiumpowdercoatedandnyl
onreceiver,cornerbracketsmadeofCRCA
withZincPhosphate,Mullion caps made
of glass filled
nylon,framesfixedtotheconcrete/masonr
y
135
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
wall by means of self expanding
screwsincluding 10 mm square guard
bars
with6"pitchcompleteforfinisheditemofwor
k.
Ventilators:TopHung2'-0"x2'-
859 MAT-01418 BMT-P.10 0"(609.6x609.6mm)outerframesectionsiz 1 6295
e of 46mm x 52 mmshutter Sqm
framesectionsizeof 46mmx46mm
Ventilators:TopHung4'-0"x2'-
0"(1219.2x609.6mm)outer frame 1
860 MAT-01419 BMT-P.11 sectionsize of 46 x 52 m shutter frame Sqm 6295
sectionsize of 46 x 46 mm Mullion
section sizeof46x 70mm
Ventilators:TopHung4'-0"x3'-
0"(1219.2x914.4mm) outer frame 1
861 MAT-01420 BMT-P.12 sectionsizeof46x52mmshutterframesecti Sqm 6295
onsizeof46x46mmMullionsectionsizeof4
6x 70mm
Supplying and fixing of Fixed
LouveredVentilatorsmade of pre -
painted steel(base steel as per IS 513 of
-0.58
mmthick'D"quality,galvanizedasperIS
277withzincof120GSM)primercoated
with epoxy primer of 5-7
micronsthick,finishpaintedwithapolyester
paint of 12-16 microns thick and
backcoatedwith5-
7micronsthickalkydbacker,Thesectionfor
louveredventilators should be of of 33 x
56 mmBox section paneled with4 mm
pinheadglasswithEthylpropyleneDiamine
monomerGasket(EPDM)andthesections
cut to length mitre joined
withcornerbracket.cornerbracketsmadeo
fCRCAwithZincPhosphate.Theframesto
befixedtotheconcrete
/masonrywallbymeansofselfexpandingsc
rewsincluding10mmsquareguardbarswit
h6"pitchcompleteforfinished itemofwork.
Ventilators:Fixedlouvers2'-0"x2'-
862 MAT-01421 BMT-P.13 1 4306
0"(609.6x609.6mm)(Boxsection)outerfra
Sqm
mesectionsizeof33x 56mm
Ventilators:Fixedlouvers4'-0"x2'-
863 MAT-01422 BMT-P.14 0"(1219.2 x 609.6 mm) (Box section) 1 4306
outerframesectionsizeof33x56mmMullio Sqm
nsectionsizeof33x56mm
Ventilators:Fixedlouvers4'-0"x3'-
864 MAT-01423 BMT-P.15 0"(1219.2 x 914.4 mm) (Box section) 1 4306
outerframesectionsizeof33x56mmMullio Sqm
nsectionsizeof33x56mm

136
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
865to BMT-P.68 ITEMSDELETED
868 toP.75
Providing and fixing 3 Track 3
ShutterPre painted Steel sliding
Window/Doorfabricatedfromrollformedse
ctionsmadeofGalvanizedsteelcolourcoat
ed
/powder coated (Base Steel as per
IS513 ‘D’ quality galvanized as per IS
277with Zinc of 120 Gms./ Sq.mtr) with
totalcoatedthicknessof0.58mm.PrimerC
oat with epoxy primer of 5-7
micronsthick,finishedpaintwithapolyester
paint of 12-16 microns thick and
backcoated with Alkyd backer of 5-7
micronsorpowdercoatedwithpurepolyest
erpowder up to 50-60 microns thick.
TheExternal Section for Three Track
ThreeSlidingShuttershouldbeof44x107m
m with a provision for bottom
trackinsertprofileof10x9mmmadeofalumi
nium.SectionforWindowglassshutter
should be of 35x49mm, Sectionfor
Window Euro grooveshould be
869 MAT-01488 BMT-P.77 1 6818
of25x24mmmadeofplastictoaccommodat
Sqm
estandardaccessories,and section for
window lap strip shouldbe of 21x4mm
made of plastic.
SectionforMeshShuttershouldbeof35x49
mm.SectionforDoorshuttershould be of
35x67mm, Section for DoorEuro Groove
25x31mm made of
plastictoaccommodatestandardaccessor
iesandsizeoflapstripshouldbeof39x41m
m.TheWindow/Doortobepanelledwith5m
mthickplainfloatglass. The gaskets are
to be made
ofEthylPropyleneDiamineManomer[EPD
M].CornerBracketsforinternaland
external frame to be made of glassfilled
nylon. Touch locktobe providedfor
Window Shutter. Sections are to becut
to length, joined and assembled
bymeansofcornerbrackets.Theabovefra
metobefixedtoBrick/Concretemasonry
by using Nylon self-
expandingcapsanddrivingMSelectroplat
ed80mmscrewsintothecapsthroughfram
es. The Grill for safety for windowsto be
made of 10mm thick square rodbars
with 152mm pitch for complete itemof
work .For Door there will be
noSafetyGrillincludingcostandconveyanc
eofallmaterials,accessories, labour
charges for

137
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
transportation,erectionatsitecompleteforf
inisheditemofwork.
Q.SECTION STRUCTURALGLAZING
I.SUB- FIXEDGLAZING
SECTION
870 MAT-01496 BMT-Q.08 ITEMDELETED
871 MAT-01497 BMT-Q.09 ITEMDELETED
II.SUB- STRUCTURALGLAING
SECTION
Providing and fixing Structural
GlazingfabricatedfromRollformedsectio
nsmadeofPre-
paintedSteel/Powdercoated (Base steel
as per IS 513 of ‘D’quality, galvanized
as per IS 277 withZinc of 120 Gm/Sqm)
with total
coatedthicknessof0.72mmandtheglassh
oldingsectionmadeof304gradestainlesss
teelof0.58mmthickgalvanisedsteelsectio
nasstiffenersinsidethecolourcoatedsteel
powdercoatedsectionsasperthedesignre
quirement & calculations to suit
windpressures as given in IS: 875, the
primercoat with epoxy primer of 5 – 7
micronsthick,finishpaintedwithapolyester
paint of 12-16 microns thick and
backcoated with Alkyd backer of 5-7 1
872 MAT-01489 BMT-Q.01 micronsorpowdercoatedwithpurepolyest Sqm 6625
erpowder up to 50-60 microns thick
andtheverticalsectionof50mmx99mmx
0.72mm,33mmx56mmx0.72mmforframe
horizontalsection,stiffenersection of 47
mm x97mm x1 mm,cover profiles
sections of 20 mm x
58mmx0.58mm,glassholdingsectionof
37 mm x 37 mm & 37 mm x 18
mmincluding fixing 5mm thick Ocean
Bluereflective glass, brackets made of
CRCApowder coated/Electroplated to
connectvertical to horizontal, vertical to
slab, tofix verticals at top & bottom as
per siterequirement and gasket made of
EthylPropyleneDiamineMonomer,U.V.re
sistantsiliconsealantincludingfixingincon
crete/masonrywallwithself-
expandingcap&screwsinclusiveofcost
and conveyance of all materials
tosite,alllabourcharges,incidentalcharge
s,costofallconsumablesetc.and fixing
charges complete for finisheditem
ofwork.

138
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Providing and fixing Top Hung
shuttersinStructuralGlazingfabricatedfr
omRollformedsectionsmadeofPre-
paintedSteel/Powdercoated(Basesteela
sperIS513of‘D’quality,galvanizedasperIS
277withZincof
120Gm/Sqm)withtotalcoatedthicknessof
0.72mmandtheglassholdingsectionmade
of304gradestainlesssteelof0.58mmthick,
dulyprovidingstiffenersinsidethecolourco
ated steel/powder coated sections asper
the design requirement, calculationsto
suit wind pressures as given in IS 1
873 MAT-01490 BMT-Q.02 Sqm 5355
875and primer coat with epoxy primer of
5-7micronsthickandbackcoatedwithAlkyd
backer of 5-7 microns or powdercoated
with pure polyester powder up to50-60
microns thick and the outer frameof 20
mm x 58 mm x 0.58 mm, shuttersections
of 57 mm x 33 mm x 0.72 mm,stiffener
sections of 55 mm x 31 mm x1mm,
hinges – 2 Nos for each shutterand
aluminium Stays – 2 Nos. for
eachshutter, aluminium Handle– 1 no.
foreachshutterincludingcostandconveya
nce of all materials to site, alllabour
charges, incidental charges,
costofallconsumablesetc.andfixingcharg
esetcforfinisheditemofwork

III CURTAINWALLING
Supplying and fixing of curtain
Glazingmade of pre painted steel (base
steel asper IS 513 of 0.58 mm thick D
quality,galvanizedasperIS277withZincof
120GSM)Primercoatedwithepoxyprimer
of5-7micronsthick,finishpainted with a
polyester paint of 12- 16microns thick
and back coated with 5-
7micronsthickalkydbackerusingthesectio
n for outer frame of 46 x 52 mm,section 1
874 MAT-01491 BMT-Q.03 Sqm 5466
for mullion of 46 x 70 mm andsection for
beading of 18 x 25 mm andthe glazing
with 5 mm thick plain
floatglassfittedwithEthylPropylenediamei
neMonomer(EPDM)gasketsandthesectio
nscuttolength,mitrejoinedwithcornerbrac
ket,centremullions fixed suing mullion
cap inludinghandle made of high grade
Aluminiumpowdercoatedandnylonreceiv
er,cornerbracketsmadeofCRCAwithzinc
phosphating, mullion caps made
ofGlassfillednylonincludingfixingthe

139
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
frames in the concrete / masonry
wallwithselfexpandingscrews,etc.,compl
eteforfinisheditem.-FixedGlazing2'-0"x2'-
0"(609.6x609.6mm)grid outer frames
section size of 46 x 52mm

Mullionsectionsizeof46x70mmBeading
section size of 18 x 25 mm - 1
875 MAT-01492 BMT-Q.04 FixedGlazing2'-0"x3'- Sqm 5466
0"(609.6x914.4mm)gridouterframesectio
nsizeof46x 52mm
Mullionsectionsizeof46x70mmBeadings
ectionsizeof18x25mmFixedGlazing3'- 1
876 MAT-01493 BMT-Q.05 0"x3'- Sqm 4295
0"(914.4x914.4mm)gridouterframesectio
nsizeof46x 52mm
Mullionsectionsizeof46x70mmBeadings
ectionsizeof18x25mmFixedGlazing3'- 1
877 MAT-01494 BMT-Q.06 0"x4'- Sqm 4295
0"(914.4x1219.2mm)gridouterframesecti
onsizeof46x 52mm
878 MAT-01495 BMT-Q.07 ITEMDELETED
DISMANTLING clearing away
S.SECTION andcarefullystackingmaterialsusefulf
orreuse.
Stonemasonryincementmortar 1
879 MAT-01498 BMT-S.01 415
Cum
Terracingwork inroofsorfloors 10
880 MAT-01499 BMT-S.02 175
Sqm
Flatstonesinroofor 10
881 MAT-01500 BMT-S.03 152
floorsincludingli Sqm
fting
PantiledorMangaloretiledroofwithoutrooft 10
882 MAT-01501 BMT-S.04 127
imbers. Sqm
FlatandpantilesorMangaloretilesoverflatti 10
883 MAT-01502 BMT-S.05 152
leswithoutrooftimbers Sqm
Wroughtandframedtimberinroofsorfloors 1
884 MAT-01503 BMT-S.06 219
Cum
Oldlimemortarplaster 10
885 MAT-01504 BMT-S.07 46
Sqm
Oldcementmortar plaster 10
886 MAT-01505 BMT-S.08 58
Sqm
Dryroughstonerevetmentforapronsandsta 1
887 MAT-01506 BMT-S.09 69
ckingwithin40 Mlead Cum
Revetmentforapronsandstackinggrouted 1
888 MAT-01507 BMT-S.10 51
within40lead Cum
889 MAT-01508 BMT-S.11 KadapaslabsorShahabadstoneslabs 10 70

140
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
flooringonsandbed Sqm
Through scraping of old 10
890 MAT-01509 BMT-S.12 46
plasteredsurface Sqm
Washing of plastered surface with
891 MAT-01510 BMT-S.13 10 15
soap,soda and water (or with soda lime
Sqm
andwater)
clean removal of lime plaster from
892 MAT-01511 BMT-S.14 wallsand raking out joints 20mm deep or 10 46
fromterraced roof and raking out joints Sqm
100mmdeep
Cleanremovalofcementplasterfromwalls 10
893 MAT-01512 BMT-S.15 57
and rakingoutjoint200mmdeep Sqm
T.SECTION READYMIXCONCRETE DELETED
U.SECTION EXPANSIONJOINTFILLERS
Supplyofhighperformanceexpansionjoint
MAT-01513 BMT-U.01 1 686
894 fillerboardconformingtoM.O.S.T
Sqm
-18mmTHICK
Supplyofhighperformanceexpansionjoint
MAT-01514 BMT-U.02 1 770
895 fillerboardconformingtoM.O.S.T
Sqm
-20mmTHICK
Supplyofhighperformanceexpansionjoint
MAT-01515 BMT-U.03 1 960
896 fillerboardconformingtoM.O.S.T
Sqm
-25mmTHICK
Supply of expansion joint filler board
MAT-01516 BMT-U.04 1 275
897 forbuildings,columns,beamsandslabs20
Sqm
mmTHICK
Supply of expansion joint filler board
MAT-01517 BMT-U.05 1 340
898 forbuildings,columns,beamsandslabs25
Sqm
mmTHICK
Supply of expansion joint filler board
MAT-01518 BMT-U.06 1 685
899 forbuildings, columns, beams and slabs
Sqm
50mmTHICK
Supplyofbackuptocoldappliedsealant in
900 MAT-01519 BMT-U.07 construction and longitudinaljoint- 1RM 11.5
10mmOD
Supplyofbackuptocoldappliedsealant in
901 MAT-01520 BMT-U.08 construction and longitudinaljoint- 1RM 13.5
12mmOD
Supplyofbackuptocoldappliedsealant in
902 MAT-01521 BMT-U.09 construction and longitudinaljoint- 1RM 15.5
15mmOD
Supplyofbackuptocoldappliedsealant in
903 MAT-01522 BMT-U.10 construction and longitudinaljoint- 1RM 22
20mmOD
Supplyofbackuptocoldappliedsealantinc
904 MAT-01523 BMT-U.11 1RM 28
onstructionandlongitudinal

141
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
joint-25mmOD
V.SECTION LABOURCHARGES
Bailingoutwaterforearthworkexcavation/c
oncreteforfoundationbelowwaterlevel.(F
905 MAT-01524 BMM-V.01 orbuildingitemsonly)- 1cum 257
Otherthansandysoil-0.0Mto
1.0M
Bailingoutwaterforearthworkexcavation/c
oncreteforfoundationbelowwaterlevel.(F
906 MAT-01525 BMM-V.02 orbuildingitemsonly)- 1cum 304
Otherthansandysoil-1.0Mto
2.0M
Bailingoutwaterforearthworkexcavation/c
oncreteforfoundationbelowwaterlevel.(F
907 MAT-01526 BMM-V.03 orbuildingitemsonly)- 1cum 355
Otherthansandysoil-2.0Mto
3.0M
Bailingoutwaterforearthworkexcavation/f 408
MAT-01527 BMM-V.04 orconcretefoundationbelowwaterlevel.(F 1cum
908
orbuildingitemsonly)Sandysoil -
0.0Mto1.0M
Bailingoutwaterforearthworkexcavation/f
MAT-01528 BMM-V.05 orconcretefoundationbelowwaterlevel.(F 1cum 635
909
orbuildingitemsonly)Sandysoil -
1.0Mto2.0M
Bailingoutwaterforearthworkexcavation/c
MAT-01529 BMM-V.06 oncreteforfoundationbelowwaterlevel.(F 1cum 767
910
orbuildingitemsonly)Sandysoil -
2.0Mto3.0M
Labour charges for making,
fabricatingofficefurniture,racks,work-
stationfurniture,cup-
boardshutterswithply-
LAB-00418 BMM-V.07 1 644
wood/MDFsheets,decolam/veneerlamin
911 Sqm
ationsincludingfixingcutting,making,
assembling, fixing hinges,
fixingfixtures,fixinglocks,pastingsheets/la
minationsfixinginpositionwithnecessarys
crewsexcludingcostofmaterials,
accessories,fittings
Labour charges for making,
fabricatingkitchenfurniture,cup-
boardswithshutters,boxcup-
boards,boxracks,withply-
LAB-00419 BMM-V.08 wood/MDFsheets,decolam/veneerlamin 1 984
912 ationsincludingfixingcutting,making,asse Sqm
mbling,fixinghinges,fixingfixtures,fixinglo
cks,pastingsheets/laminationsfixinginpos
itionwithnecessaryscrewsexcluding cost
of materials, accessories,fittings

142
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
RoundingtheedgesofKadapa/Shahabad
913 LAB-00503 BMM-V.09 stone slabs of any 1Rm 111
thicknessincludingpolishingthesame
HalfRoundingtheedgesofMarble/Granite
914 LAB-00504 BMM-V.10 stoneslabsofallthicknessesincludingpolis 1Rm 338
hingthesame.
FullRoundingtheedgesofMarble/Granites
915 LAB-00505 BMM-V.11 toneslabsofallthicknessesincludingpolish 1Rm 438
ingthesame.
Machine Cutting charges- for
916 LAB-00506 BMM-V.12 Marble/Graniteslabsupto50mmthickbym 1RM 18
echanicaldevice.
FlatnosingtoKadapa/Shahabadstoneslab
917 LAB-00507 BMM-V.13 1Rm 53
sofany thick
Labourchargesforfabricatingsteelworksli
keWindowGrills,CompoundWallGrills,Iro
LAB-00420 BMM-V.14 nDoors,Windowsincludingcostofweldingr 1Kg 28
918
ods,powercharges,excludingcostoffixingi
nposition

LabourchargesforfixingIronDoors,IronWi
919 LAB-00421 BMM-V.15 ndowsandWindowGrillsinposition 1Kg 5

Labour charges for fabricating all


heavysteelworkslikeTrusses,Stanchions,
920 LAB-00422 BMM-V.16 HeavyBeamsandGirdersincludingcost of 1Kg 25
welding rods, power charges,
etcexcludingcostoffixing inposition
Labourchargesforfixingheavyirongrills,Tr
usses,Stanchions,HeavyBeams and 22
LAB-00423 BMM-V.17 Girders erecting in positionand fixing by 1Kg
921
using chain pulley
blocks,Derekpolearrangementsandcran
esetc.,completeinposition
LabourchargesforFabricationofstainless
steelrailingworksusingstainlesssteelweld
922 LAB-00424 BMM-V.18 ingrodsincludingbuffing,polishing,lacque 1Kg 139
rfinishing,topresentseamless finish

LabourchargesforFabricationofstainless
steelsheetcladdingworksusingstainlessst
923 LAB-00425 BMM-V.19 eelweldingrodsincludingbuffing,polishing 1sqm 1817
,lacquerfinishing,topresentseamlessfinis
h
LabourchargesforGlassdesigningworkso
LAB-00426 BMM-V.20 1 1017
924 nanythicknessofGlassincludingfixingatsit
Sqm
e -Etchingworks
925 LAB-00427 BMM-V.21 LabourchargesforGlassdesigning 1 1258

143
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
worksonanythicknessofGlassincluding Sqm
fixing at site - Reverse Etchingwork

LabourchargesforGlassdesigningworkso
LAB-00428 BMM-V.22 1 1573
926 nanythicknessofGlassincludingfixingatsit
Sqm
e-Acidwashworks
LabourchargesforfixingFlushdoorshutter
s of any thickness to the existingdoor 1
927 LAB-00429 BMM-V.23 frame including fixing the fixtures Sqm 407
tothedoorshutterexcludingcostofshutter

Labour charges for fixing glass panes


LAB-00430 BMM-V.24 ofanythicknesstotheexistingdoor/window 1 304
928 Sqm
panesincludingfixingthebeadingexcludin
gcostofbeading
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
929 LAB-00431 BMM-V.25 ators including fixing all 1sqm 1672
necessaryfixturesetc.forTeakwoodFullyp
anelleddoorsexternalorinternalincludingf
rame
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
LAB-00432 BMM-V.26 ators including fixing all 1sqm 1580
930
necessaryfixtures etc. for Teak wood
Glazed
andpanelleddoorsincludingfixingglassinc
ludingframe
Labour charges for wrought and put
upincluding fixing in positionframes of
LAB-00433 BMM-V.27 anysize,shuttersfordoors,windows,ventil 1sqm 1386
931
ators including fixing all
necessaryfixtures etc. for Teak wood
Framed andplankeddoorsincludingframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
932 LAB-00434 BMM-V.28 ators including fixing all 1sqm 1094
necessaryfixturesetc.forTeakwoodLedge
d,bracedandplankeddoorsincludingfram
e
Labour charges for wrought and put
upincluding fixing in positionframes of
LAB-00435 BMM-V.29 anysize,shuttersfordoors,windows,ventil 1sqm 836
933
ators including fixing all
necessaryfixtures etc. for Teak wood
Flush typedoorshutterincludingframe
Labourchargesforwroughtandputupinclu
934 LAB-00436 BMM-V.30 1sqm 1070
dingfixinginpositionframes ofany

144
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
size,shuttersfordoors,windows,ventilator
s including fixing all
necessaryfixturesetc.forTeakwoodWind
owsglazed including outer frame and
shutterframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
935 LAB-00437 BMM-V.31 ators including fixing all 1sqm 1613
necessaryfixturesetc.forTeakwoodWind
owspanelledincludingouterframeandshut
terframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
936 LAB-00438 BMM-V.32 ators including fixing all 1sqm 1100
necessaryfixturesetc.forTeakwoodWind
owsledged,bracedandplankedincludingo
uterframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
937 LAB-00439 BMM-V.33 ators including fixing all 1sqm 1317
necessaryfixturesetc.forTeakwoodWind
owsframedandplankedincludingouterfra
me andshutterframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
938 LAB-00440 BMM-V.34 ators including fixing all 1sqm 887
necessaryfixtures etc. for Teak wood
Ventilatorsglazed, fixed with double
frame with wirenetting includingframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil 1121
939 LAB-00441 BMM-V.35 ators including fixing all 1sqm
necessaryfixturesetc.forTeakwoodSwing
ventilators glazed including outer
frameandshutterframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
LAB-00442 BMM-V.36 ators including fixing all 1sqm 630
940
necessaryfixtures etc. for Teak wood
Weld
meshdoorsandwindowsincludingouterfra
me andshutterframe
Labour charges for wrought and put
LAB-00443 BMM-V.37 upincluding fixing in positionframes of 1sqm 733
941
anysize,shuttersfordoors,windows,ventil
atorsincludingfixingallnecessary

145
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
fixtures etc. for Teak wood G.I or
.ACsheetdoor&windowsincludingouterfr
ame andshutterframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
942 LAB-00444 BMM-V.38 ators including fixing all 1sqm 1546
necessaryfixturesetc.forOtherthanteakw
oodFully panelled doors external or
internalincludingframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
943 LAB-00445 BMM-V.39 ators including fixing all 1sqm 1478
necessaryfixturesetc.forOtherthanteakw
oodGlazedandpanelleddoorsincludingfixi
ngglass including frame
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
944 LAB-00446 BMM-V.40 ators including fixing all 1sqm 1282
necessaryfixturesetc.forOtherthanteakw
oodFramedandplankeddoorsincludingfra
me
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
945 LAB-00447 BMM-V.41 ators including fixing all 1sqm 1000
necessaryfixturesetc.forOtherthanteakw
oodLedged,bracedandplankeddoorsincl
udingframe
Labour charges for wrought and put
upincluding fixing in positionframes of
LAB-00448 BMM-V.42 anysize,shuttersfordoors,windows,ventil 1sqm 800
946
ators including fixing all
necessaryfixturesetc.forOtherthanteakw
oodFlushtype doorshutterincludingframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
947 LAB-00449 BMM-V.43 ators including fixing all 1sqm 1000
necessaryfixturesetc.forOtherthanteakw
oodWindows glazed includingouter
frameandshutterframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
948 LAB-00450 BMM-V.44 ators including fixing all 1sqm 1490
necessaryfixturesetc.forOtherthanteakw
oodWindows panelled including outer
frameandshutterframe

146
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
949 LAB-00451 BMM-V.45 ators including fixing all 1sqm 1019
necessaryfixturesetc.forOtherthanteakw
oodWindowsledged,bracedandplankedi
ncludingouter frame
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
950 LAB-00452 BMM-V.46 ators including fixing all 1sqm 1217
necessaryfixturesetc.forOtherthanteakw
oodWindows framed and planked
includingouterframeandshutterframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
951 LAB-00453 BMM-V.47 ators including fixing all 1sqm 862
necessaryfixturesetc.forOtherthanteakw
oodVentilatorsglazed,fixedwithdoublefra
mewith wirenettingincludingframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
952 LAB-00454 BMM-V.48 ators including fixing all 1sqm 1075
necessaryfixturesetc.forOtherthanteakw
oodSwing ventilators glazed including
outerframe andshutterframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
953 LAB-00455 BMM-V.49 ators including fixing all 1sqm 600
necessaryfixturesetc.forOtherthanteakw
oodWeldmeshdoorsandwindowsincludin
gouterframeandshutterframe
Labour charges for wrought and put
upincluding fixing in positionframes of
anysize,shuttersfordoors,windows,ventil
LAB-00456 BMM-V.50 ators including fixing all 1sqm 700
954
necessaryfixtures etc. for Other than
teakwood G.Ior .ACsheet door &
windows
includingouterframeandshutterframe
955 LAB-00508 BMM-V.51 Grooves2-3mm 1Rm 58
W.SECTION MISCELLANEOUSITEMS
Supplying Aluminium anodised
956 MAT-01575 BMS-W.01 SectionsforDoors,partitions,windows,Ve 1Kg 306
ntilators(includingannodizationcost)
SunControlfilmtotheglazedwindowspartit
957 MAT-01576 BMS-W.02 1sqm 313
ion includinglabourcharges.

147
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
AluminiumVenetianBlindshorizontal
958 MAT-01577 BMS-W.03 1sqm 798
25.4mm widewith allaccessories.
AluminiumVenetianBlindshorizontal
959 MAT-01578 BMS-W.04 1sqm 760
20.0mm widewith allaccessories.
VenetianblindsVerticalblinds100mmwide
960 MAT-01579 BMS-W.05 1sqm 1290
withallaccessories.
961 MAT-01580 BMS-W.06 RubberBeading 1RM 2
Chlorpyriphos/ Lindane
MAT-01581 BMS-W.09 1Litre 217
962 emulsifiableconcentrat
e of20%
963 MAT-01582 BMS-W.10 SoftBrush Each 141
964 MAT-01583 BMS-W.11 WireBrush Each 31
Supplyingandfixingaluminiumcomposit
ecladdingwithskinmaterial0.25mmthi
ckaluminiumsheetcovermaterialnatural
polyethylene aluminium cladding
panelfixedwithextrudedaluminiumbasisfr
ame(50x25x1.5mm)anglecleats,weather
sealants, rivets, GI brackets 1
MAT-01584 BMS-W.12 Sqm 2189
allasapproved,usingsuitableboltsonstruc
965 tural steel work including
necessaryaccessoriescompleteinallresp
ectsincludingallscaffoldingandlabourchar
ges etc., complete for finished itemof
work but excluding cost of
structuralsteel fabrication, if any, ACP
Cladding-3mmthk

Supplyingandfixingaluminiumcomposit
ecladdingwithskinmaterial0.25mmthi
ckaluminiumsheetcovermaterialnatural
polyethylene aluminium cladding
panelfixedwithextrudedaluminiumbasisfr
ame(50x25x1.5mm)anglecleats,weather
sealants, rivets, GI brackets 1
MAT-01585 BMS-W.13 Sqm 2387
allasapproved,usingsuitableboltsonstruc
966 tural steel work including
necessaryaccessoriescompleteinallresp
ectsincludingallscaffoldingandlabourchar
ges etc., complete for finished itemof
work but excluding cost of
structuralsteel fabrication, if any, ACP
Cladding-4mmthk

Supplyingandfixingaluminiumcomposit
ecladdingwithskinmaterial0.5mmthic
kaluminiumsheetcovermaterialnaturalp 1
967 MAT-01586 BMS-W.14 olyethylene aluminium cladding Sqm 2678
panelfixedwithextrudedaluminiumbasisfr
ame(50x25x1.5mm)anglecleats,

148
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
weather sealants, rivets, GI brackets
allasapproved,usingsuitableboltsonstruc
tural steel work including
necessaryaccessoriescompleteinallresp
ectsincludingallscaffoldingandlabourchar
ges etc., complete for finished itemof
work but excluding cost of
structuralsteel fabrication, if any, ACP
Cladding-4mmthk

968 MAT-01587 BMS-W.15 CEMENTJALI-25mmthick 1sqm 198

969 MAT-01588 BMS-W.16 CEMENTJALI-40mmthick 1sqm 257

970 MAT-01589 BMS-W.17 CEMENTJALI-50mmthick 1sqm 353


Aluminiumsheet24Gauge 1
MAT-01590 BMS-W.18 256
971 Sqm
7.5mmthickAluminiumGrill(asapprovedb
MAT-01591 BMS-W.19 1 941
ythedepartment)3.58Kg/Sqm.
Sqm
972
Mastic pad2'0 "x4'0"(0.60M x 1
MAT-01592 BMS-W.20 839
973 1.2M)of1"(25.4mm) thick Sqm
Mastic pad2'0 "x4'0"(0.60M x 1
MAT-01593 BMS-W.21 481
974 1.2M)of1/2"(12.7mm)thick Sqm
Supplyofhotpressedcompressionmoulde
dsignplatesformakingroadsigns ass per
the approved dimensionsof National
Highway Authority Of India,complete,
forfinished itemofwork.

975 MAT-01594 BMS-W.22 CircularsignplateDia400mm. Each. 488

976 MAT-01595 BMS-W.23 CircularsignplateDia600mm. Each. 1284

977 MAT-01596 BMS-W.24 CircularsingplateDia870mm Each. 2574

978 MAT-01597 BMS-W.25 Triangularsignplate600mm. Each. 659

979 MAT-01598 BMS-W.26 Triangularsign plate900mm. Each. 1489

980 MAT-01599 BMS-W.27 Squaresignplate600mm. Each. 1194

981 MAT-01600 BMS-W.28 Squaresignplate1000mm. Each. 4433

982 MAT-01601 BMS-W.29 ITEMDELETED


Design,fabrication&supplyoflightweightp
reengineeredbuildingsforamaximum
span of 9 metres with 50 x 50x 2.8 mm
M.S hollow square tubes
forcolumns,trusses&purlinswallswithsan
dwichpanelsmadeupof2Nos10mmthickc
ementbondedparticle/fibre boards with
25mm thick 12
kg/cumdensityexpandedpolystyreneinbe
tweenencasedin1.25mmthick24x7x26
mm ‘W’ tracks in bottom &
topand‘H’sectionforsideswithdoors,

149
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
windows & ventilators, roofing with
26gauge pre painted profiled sheets
fixedwithselftapping/drillingscrews,painti
ngwithenamelpaintforsteelitems,OBDfori
nteriorsandaceforexteriors&providingbas
eplates,templates & anchor bolts along
with civilfoundation designs & drawings
for thefinished itemofwork

SteelStructure:-Structureismadeupof
MAT-01602 BMS-W.30 50x50X 2.8 mm/33x66x2.8mm 1RM 363
983
thickhollowM.S.sectionsforTrusses,colu
mns,andpurloins.-Columns
Sandwichpanels:Sandwichpanelsof50
mm thick with 25 mm thermocol of 12kg
/ cum, fixed in between 2 Nos 10 1
984 MAT-01603 BMS-W.33 mmcementbondedwoodparticle/fibreboa Sqm 1312
rds properly fixed together with
30mmx30mmx30mmwoodpiecesalongw
idth& lengthwherevernecessary
U' Tracks & 'H' Section:- Bottom &
MAT-01604 BMS-W.34 Top'U' Tracks are made of 1.25 mm 1RM 141
985
thick120 GSM G.I. Sheet of size
24x51x26mmsize.
Fabricated 'H' sections are made up of
2Nos 1.25 mm thick C.R. Of 40 mm
986 MAT-01605 BMS-W.35 widthforflangesand1Nosof 2mmthick 1RM 204
C.R. of 50 mm width plate for web.
willbeused
Sandwich Panel joinery is made up
ofcouplersorequivalentmadefrom0.6mm
987 MAT-01606 BMS-W.36 G.I. rollformedsection tohold2Nos of 10 1RM 233
mm board on both sides with25mm
thermocolinbetween.
Window:- windows are made up of
51x51 mm step 'U' section made from
1.25thickMSColdrolledSteelSheetandWi
ndows Shutters & Grill are made 1
MAT-01607 BMS-W.37 Sqm 4211
988 of48x25mm mm size pre painted
sectionwith4mmglasscompletewithnece
ssaryhardware.Grillsaremadefrom8mms
quarerodat100mmspacing.

DoorFrames:-51X51Stepped'U'section
made from 1.25 mm thick C.R.section
with a 32 mm rebate for 30 1
989 MAT-01608 BMS-W.38 mmflushdoorandDoorShutterswith30mm Sqm 3838
thick block board / flush doors
withboilingwaterproofplywoodcompletew
ith necessaryHardware.
990 MAT-01609 BMS-W.39 Ventilators:-Ventilatorsaremadeof 1 4294

150
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
51x51mmstep'U'sectionmadeFrom Sqm
1.25mmthickC.R.sheetwithfixedlouvers
andglass.
Painting:-1)Steelstructureistobepainted
MAT-01610 BMS-W.40 1 114
991 with 2 coats of Grade I enamelpaint.
Sqm

2) Exterior walls arepainted with


MAT-01611 BMS-W.41 1 102
992 onecoast of primer and 2 coats of
Sqm
exterioremulsionpaint.
3)Interiorsarepaintedwith1+2coatofO.B. 1
993 MAT-01612 BMS-W.42 85
D. Sqm
Toilets:-Toiletsareprovidedasperplan
with a provision for fixing the washbasin,
MAT-01613 BMS-W.43 W.C. etc only is made with M.S.steel Each 998
994
section secured to the walls withtoilet
bracket provision excluding cost ofWC/
Washbasinetc
Sunshades:-Sunshadeswillbeprovided
wherever necessary with
300mmmorethanthewidthofwindow.25x2
MAT-01614 BMS-W.44 5 mm angle frame to cover 450 mmin Each 3364
995
the front and the sides. 10mm
cementbonded particle boardwillbe fixed
onthe frame work and sealed with
greenpasteorequivalent.
Roofing: - Roofing will be provided
with0.5mmthickgalvanized/prepainted
G.I. profiled sheets fixed to the
purlinswith14sizeselfdrillingscrewswithn 1
MAT-01615 BMS-W.45 Sqm 760
eoprene washer. Side laps are
996 stitchedwith self tapping / drilling
screws.
Endlapsaretobesealedwith25x3mmButyl
tape. The sheets are provided
withanticapillarygrove.
997 MAT-01617 BMS-W.47 Preparinggabionswithjunglewood Each
3
998 MAT-01618 BMS-W.48 Plantingplants Each
2
999 MAT-01619 BMS-W.49 Pruningplants Each
3
Maintainingavenuesincludingfencing,w
1000 MAT-01620 BMS-W.50 eeding, mulching, watering etc Each
perplant. 7.5
-do-
1001 MAT-01621 BMS-W.51 Whenscatteredinhotweatherwith extra Each
conveyance from March toJune 8.5
1002 MAT-01622 BMS-W.52 Hoistingorloweringofslab 1cum 118
Dressingfacesofgranitestone(doublelin 1
1003 MAT-01623 BMS-W.53 194
edressing) Sqm
1004 MAT-01624 BMS-W.54 Dressingfacesofotherthangranite 1 121

151
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
stone(doublelinedressing) Sqm
Supply of Pre-painted
GalvalumeTrapezoidal Profile Roofing
sheets with0.50mm thickness, Coating:
Alu-Zinccoating AZ150 GSM. Tensile
MAT-01625 BMS-W.55 1 421
Strength:550 MPA. Paint coating:
1005 Sqm
RegularModified Polyester painting.
PaintingThickness (Top): 18 to 20
Microns,(Bottom): 5 to 7 Microns. Sheet
Width:1.020,Length:Maximum12Meters
withRegularRangeColours
Supply of Pre-painted
GalvalumeTrapezoidal Profile Roofing
sheets with0.47mm thickness, Coating:
Alu-Zinccoating AZ150 GSM. Tensile
MAT-01626 BMS-W.56 1 411
Strength:550 MPA. Paint coating:
1006 Sqm
RegularModified Polyester painting.
PaintingThickness (Top): 18 to 20
Microns,(Bottom): 5 to 7 Microns. Sheet
Width:1.020,Length:Maximum12Meters
withRegularRangeColours
Supply of Pre-painted
GalvanizedTrapezoidal Profile Roofing
sheets
with0.50mmthickness,Coating:Zinccoati
MAT-01627 BMS-W.57 1 370
ng Z120 GSM. Tensile Strength:300
1007 Sqm
MPA. Paint coating: RegularModified
Polyester painting. PaintingThickness
(Top): 18 to 20 Microns,(Bottom): 5 to 7
Microns. Sheet
Width:1.020,Length:Maximum12Meters
withRegularRangeColours
SupplyofPre-
paintedGalvanizedTrapezoidal Profile
Roofing sheets
with0.47mmthickness,Coating:Zinccoati
MAT-01628 BMS-W.58 1 347
ngZ120GSM.TensileStrength:
1008 Sqm
300MPA.Paintcoating:RegularModifiedP
olyesterpainting.PaintingThickness(Top)
:18to20Microns,(Bottom): 5 to 7
Microns. Sheet Width:1.020, Length:
Maximum 12 Meters
withRegularRangeColours
SupplyofRoofAccessoriesmediumsize:
Ridge, Barge Cap, Corner Trim, L-
1009 MAT-01629 BMS-W.59 Flashing, Down Pipes, Gutter etc., 1RM 283
with0.50mmthick,Width:0.585,Length:M
aximum 2½Meters
SupplyofRoofAccessoriesmediumsize:
Ridge, Barge Cap, Corner Trim, L-
1010 MAT-01630 BMS-W.60 Flashing, Down Pipes, Gutter etc., 1RM 253
with0.47mmthick,Width:0.585,Length:M
aximum 2½Meters

152
BasicRate
S.No ItemCode Descriptionofitem Unit forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
75mmlong screws- 1 4
1011 MAT-01631 BMS-W.61
Each
G.Iscambolts&nuts 1 5
1012 MAT-01632 BMS-W.62
Each
G.Ibolts&nuts 1 5
1013 MAT-01633 BMS-W.63
Each
G.I‘J’bolts8mmdia 1 10
1014 MAT-01634 BMS-W.64
Each
G.IWashers 1 2
1015 MAT-01635 BMS-W.65
Each
Limpetwashers(forscam&‘J’bolts) 1 2
1016 MAT-01636 BMS-W.66
Each
Bitumenwashers 1 2
1017 MAT-01637 BMS-W.67
Each
1018 MAT-01638 BMS-W.68 WhiteCement (Rate as per Common SoR) 1Kg 27.95
MSZHoldfasts - 300mm long of40x40x 1
1019 MAT-01639 BMS-W.69 35
5mmISA Each
Rubber/Nylondoorstopbushes 1
1020 MAT-01640 BMS-W.70 10
Each
Nylonrollersforslidingglasses/allumin 1
1021 MAT-01641 BMS-W.71 15
ium windows Each
Powdercoatingorcolourannodization-
1022 MAT-01642 BMS-W.72 1RM 49
anysection
Continuous Piano Hinges
MAT-01643 BMS-W.73 PowdercoatedMildsteelasperIS- 1RM 35
1023 3818:1992ofnominalsize25mm(B)ofthicknes
s
0.8to1.0mm
Boxhingesforcup boards 1
1024 MAT-01644 BMS-W.74 44
Each
MagneticCatchers 1
1025 MAT-01645 BMS-W.75 15
Each
Drillingholesinhardrocksurfacesupto18mmdia
1026 MAT-01646 BMS-W.76 1RM 200

Drillingholes inhardrockabove18mmdia
1027 MAT-01647 BMS-W.77 1RM 278

Makingholes 1
MAT-01648 BMS-W.78 34
1028 upto18mmdiainRCC/anystonesupto50 Each
mmthick
Makingholesabove18mmdiainRCC/anystones 1
1029 MAT-01649 BMS-W.79 47
above50 mmthick Each
Pressure grouting the drilled holes
MAT-01650 BMS-W.80 1 48
1030 withneatcementslurryorwithapprovedepoxybo
Each
nding agentusingpump
1031 MAT-01651 BMS-W.81 ITEMDELETED
1032 MAT-01652 BMS-W.82 ITEMDELETED

153
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
CASURINA BALLIES /
STEELBARRICADING
Fixing steel barricading with MS
AngleIron Pegs and GI Pipes with nuts
&
boltsdulyexcavatingpitsanditsremovalaft
erthefunctionisoverincludingtransporting
oftheentirebarricadingmaterials from the
Divisional stores
1033 LAB-00552 BMS-W.83 tothebarricadingsitedulyengaginglabour
to load, transport and unload
thematerials at barricading site & as per
theschedulegivenbythedepartmentalaut
horitiesandloadingbackintothetrucks,unl
oadingatDivisionalstores,accountingforth
ereceivedmaterials,labourforloading,unl
oading,fixing,handling etc, complete for
finished itemofwork
2-TIER(3days) 1RM 38.2
Providing barricading arrangement
withcasurina ballies as per the design
dulyexcavating pits and its removal after
BMS-W.84 thefunction is over including hire
charges
ofthebarricadingmaterialsasperthesched
ulegivenbythedepartmentalauthorities
complete for finished item ofwork
1034 LAB-00553 BMS-W.84.A 2-TIER(2days) 1RM 47.6
1035 LAB-00554 BMS-W.84.B 2-TIER(3days) 1RM 47.8
1036 LAB-00555 BMS-W.84.C 2-TIER(4days) 1RM 48
1037 LAB-00556 BMS-W.84.D 3-TIER(2days) 1RM 49.75
1038 LAB-00557 BMS-W.84.E 3-TIER(3days) 1RM 50
1039 LAB-00558 BMS-W.84.F 3-TIER(4days) 1RM 50.5
Testingcharges
BMS-W.85 CoarseAggregates
1040 LAB-00559 BMS- GradationTest 1No. 627
W.85.A
1041 LAB-00560 BMS-W.85.B. AggregateImpactValueTest 1No. 627
1042 LAB-00561 BMS-W.85.C FlakinessandElongationIndicesTests 1No. 730
1043 LAB-00562 BMS-W.85.D WaterabsorptionTest 1No. 575
1044 LAB-00563 BMS-W.85.E AbrasionTest 1No. 890
1045 LAB-00564 BMS-W.85.F SpecificGravityTest 1No. 627
BMS-W.86 FineAggregates
1046 LAB-00565 BMS- SieveAnalysisTest 1No. 627
W.86.A
1047 LAB-00566 BMS- Bulking&Moisturecontent 1No. 627
W.86.B

154
BasicRat
S.No ItemCode Descriptionofitem Unit e forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
1048 LAB-00567 BMS-W.86.C SpecificGravityTest 1No. 627
BMS-W.87 Cement
1049 LAB-00568 BMS-W.87.A FinenessofcementTest Each 627
1050 LAB-00569 BMS-W.87.B Initial&Finalsettingtimeofcement Each 627
BMS-W.88 Bricks
1051 LAB-00570 BMS-W.88.A CompressivestrengthofBricks Each 365
1052 LAB-00571 BMS-W.88.B WaterabsorptionTestforBrick Each 575
BMS-W.89 Concrete
Compressivestrengthofconcretei.eC 365
1053 LAB-00572 BMS-W.89.A. Each
ubestrengthtest
1054 LAB-00573 BMS-W.89.B Designmixofonegrade 16720
1055 LAB-00574 BMS-W.89.C DesignmixofTwogrades 27170
1056 LAB-00575 BMS-W.89.D Design mixofthree grades 37620
1057 LAB-00576 BMS-W.89.E Designmixoffourgrades 44935
1058 LAB-00577 BMS-W.89.F Designmixoffivegrades 53295
Steel
TensileStrengthofEachDia1set(3rods 730
1059 LAB-00578 BMS-W.90 Each
)
BMS-W.91 Soils
1060 LAB-00579 BMS-W.91.A G.S.BMixdesign Each 5225
1061 LAB-00580 BMS-W.91.B W.M.MMixdesign Each 6375
1062 LAB-00581 BMS-W.91.C B.MMixdesign Each 7840
1063 LAB-00582 BMS-W.91.D SDBC/BC Each 8465
1064 LAB-00583 BMS-W.91.E UDsamples Each 1880
1065 LAB-00584 BMS-W.91.F SoilsMDDandCBR Each 3865
Note:ItemBMS-
W.46isremovedinthesectionWandisbroughtasnew
itemintheSection NasBMT-N.82.
MACHINERY CHARGES,
X.
HIRECHARGESFOR
CENTRING
Machinechargesofrubbing/polishingflo
1066 MAT-01653 BMC-X.01 1day 1900
or
Power Saw Cutter - Hand Operated -
1067 HIR-00206 BMC-X.02 1Hr 110
Hirecharges
PowerDrill-HandOperated-
1068 HIR-00207 BMC-X.03 1Hr 103
HireCharges
1069 MAT-01656 BMC-X.04 GrindingMortar(SplGrinding) 1day 950
Casuarina Balli Props - 3" to 4" dia - 12'-
1070 MAT-01657 BMC-X.05 Each 65
0"Height
1071 MAT-01658 BMC-X.06 CasuarinaBalliProps-4"to8"dia-20'- Each 107

155
BasicRate
S.No ItemCode Descriptionofitem Unit forSoR
CFMScode
2021-
22 (Rs.)
1 2 3 4 5
0"Height
WallPlateBrackets/beambottomsu
1072 MAT-01659 BMC-X.07 Each 190
pports
1073 MAT-01660 BMC-X.08 WedgePlatefixture Each 10
Runnerbeamsofapproximately
1074 MAT-01661 BMC-X.09 RM 378
4"x4"size
MAT-01662 BMC-X.10 SteelPlatesforformworks 1 1430
1075
Sqm
ScaffoldingPipes&Centeringa
1076 MAT-01663 BMC-X.11 1Kg 107
ccessories
ScaffoldBoards-Bambooscaffolds-
1077 MAT-01664 BMC-X.12 Each 116
Bamboos - 8'0" long
Hire charges for stationary
MAT-01665 Concretepump conforming to IS 21573 305
1078
BMC-X.13 Part- 1Hr
1:2006todeliverthefreshgreenconcrete
ConcretedeliverypipesconformingtoIS15
MAT-01666 947PartI:2012tobeconnectedtothe pump 4
1079
to delivery point (150
BMC-X.14 mmDiameter)hirechargesper10RM 1Hr
Y SECTION POST TENSIONING WORKS

Supply of Freyssinet type wedge action


anchorage cone block, couplers, anchor
1080 MAT-08749 BMC-Y.01 heads and wedges of cast iron make 1 No
shot blasting finish complete assembly 1,900
of size 400 x 300 mm as per IS 1343 :
2012
Supply of GI corrugated sheathing duct
of 0.3mm thick of 90 mm size for
1081 MAT-08750 BMC-Y.02 1 RM 50
installing the tendons for bonded post
tensioning work as per IS 1343 : 2012
Supply of HDPE grout hose with flanges
for bonded post tensioning work as per
1082 MAT-08751 BMC-Y.03 1 RM
IS 1343 : 2012 30

Design and execution of post tensioning


work, including supplying, laying of HT
tendon strands, decoiling, the strands,
cutting to the required lengths, laying of
HT strands in sheathing (GI corrugated
ducts 0.3mm thick) jointing with
couplers and inserting the strands,
profiling, fixing live end anchorages,
1083 MAT-08752 BMC-Y.04 making dead end anchorages, including 1 MT
flowering the strands, fixing tendon 1,90,000
support bars, supervising the fixing of
antibursting reinforcement, stressing the
cables using hydraulic jack, end
trimming, grouting the cables, with
cement slurry, mixed with admixtures

156
with required tools, plants, and
machineries, and consumables etc.,
including all leads, lifts, coordination,
with the post- tensioning agency,
preparation of drawings, obtaining
approval from the Engineer-in-Charge
with supply of approved grade tendons
but excluding the cost of concrete,
reinforcement steel, shuttering, anchors,
sheathing duct etc.,

1 All the items to be used on the works shall be of first quality & ISI marked wherever
possible and as approved,workmanshipshallbeasapprovedbytheEngineer-In-
chargeofthework.
2 SupplyRatesforallthematerialsarebasedonmarketratesexcludingGST.
3 SSRRatesforBuildingitemsarepurelyfortheguidanceoftheofficersinpreparationofestimatesvid
epara.113ofAPPWDcode. Authority who prepares the estimate is however responsible for
proper rates as envisaged in para.45 of APPWDcode.

LEGEND:
"BMT"-X.XX,
"BMM"-X.XX,
"BMS"-X.XX,
"BMC"-X.XX
XXX- "A".XX-DenotestheSection
XXX-X."01"-DenotestheSerialNumberoftheIteminthecorrespondingSection

157
Centring
Material Labouc Charges Unit
Sl NAMEOFTHESTRUCTURALMEMBER Hirecharg harges ofMeasure
for2019-
es 20 ment
1 2 3 4 5 6
HIRE CHARGES FOR CENTERING AND SCAFFOLDING
A FOOTINGS Rs. 301 Rs. 672 Rs. 973 per1cum
B BEDBLOCKS,BANDS Rs. 67 Rs. 363 Rs. 430 per1cum
C PEDESTALS Rs. 343 Rs. 1069 Rs. 1412 per1cum
D PLINTHBEAMS Rs. 1453 Rs. 1620 Rs. 3073 per1cum
HIRE CHARGES FOR CENTERING & SCAFFOLDING - Unsupported Height upto
3.66 M Steel scaffolding pipes, jack Props, wallers, Foot plates, brackets, steel Centering
Plates,etc.,
E LINTELS Rs. 1233 Rs. 1720 Rs. 2953 per1cum
F CHAJJAS-SUNSHADES Rs. 243 Rs. 264 Rs. 507 per1sqm
G COLUMNS Rs. 371 Rs. 2415 Rs. 2786 per1cum
H BEAMS Rs. 2179 Rs. 2027 Rs. 4206 per1cum
I SLABS- Up to150mmthick Rs. 247 Rs. 241 Rs. 488 per1sqm
J SLABS -above150mm - Rs. 254 Rs. 248 Rs. 502 per1sqm
Upto300mmthick
K SLABS-above 300mmthick Rs. 265 Rs. 260 Rs. 525 per1sqm
L WAFFLE- Rs. 897 Rs. 834 Rs. 1731 per1sqm
(GRID)SLABS(RibBeamswithSlabs)
M PERGOLASLABS(OnlyRibBeams) Rs. 629 Rs. 585 Rs. 1214 per1sqm
N ARCHBEAMS-upto1.5MSpan Rs. 2477 Rs. 2304 Rs. 4781 per1cum
O ARCHBEAMS-above1.5MSpan Rs. 2512 Rs. 2336 Rs. 4848 per1cum
P DOMESLABS Rs. 4005 Rs. 3723 Rs. 7728 per1cum
Q HELICALSTAIRCASES Rs. 305 Rs. 284 Rs. 589 per1sqm
Q SHEAR WALLS, RCC WALLS, WATER Rs. 472 Rs. 510 Rs. 982 per1sqm
TANK WALLS

HIRECHARGESFORCENTERING &SCAFFOLDING -UnsupportedHeightupto3.66MCasurinaBallies,


Bamboos,WoodenReapers,Runners,WoodPosts,WallPlatesetc.,

E LINTELS Rs. 826 Rs. 1332 Rs. 2158 per1cum


F CHAJJAS-SUNSHADES Rs. 163 Rs. 204 Rs. 367 per1sqm
G COLUMNS Rs. 249 Rs. 1871 Rs. 2120 per1cum
H BEAMS Rs. 1458 Rs. 1569 Rs. 3027 per1cum
I SLABS- Up to150mmthick Rs. 165 Rs. 186 Rs. 351 per1sqm
J SLABS -above150mm - Rs. 170 Rs. 193 Rs. 363 per1sqm
Upto300mmthick
K SLABS-above 300mmthick Rs. 178 Rs. 201 Rs. 379 per1sqm
L WAFFLE-(GRID)SLABS(RibBeamswith Rs. 601 Rs. 646 Rs. 1247 per1sqm
Slabs)
M PERGOLASLABS(OnlyRibBeams) Rs. 421 Rs. 453 Rs. 874 per1sqm
N ARCHBEAMS-upto1.5MSpan Rs. 1657 Rs. 1784 Rs. 3441 per1cum
O ARCHBEAMS-above1.5MSpan Rs. 1681 Rs. 1808 Rs. 3489 per1cum
P DOMESLABS Rs. 2681 Rs. 2884 Rs. 5565 per1cum
Q HELICALSTAIRCASES Rs. 205 Rs. 220 Rs. 425 per1sqm

Centring
Material Labou Charges Unit
Sl NAMEOFTHESTRUCTURALMEMBER Hirecharg rcharg for2018- ofMeasure
es es 19 ment
1 2 3 4 5 6
HIRE CHARGES FOR ACCESS SCAFFOLDING - upto 3.66 M using Casurina Ballies, Bamboos, Wooden
Reapers,Runners,WoodPosts,WallPlatesetc.,forBRICK MASONRY/STONEMASONRY-
1sqm(WallArea)
A 1st-Floor Rs. 10.78 Rs. 84.62 Rs. 95.40 per1sqm
B 2nd-Floor Rs. 10.78 Rs. 121.18 Rs. 131.96 per1sqm
C 3rd-Floor Rs. 10.78 Rs. 157.72 Rs. 168.50 per1sqm
D 4th-Floor Rs. 10.78 Rs. 194.27 Rs. 205.05 per1sqm
E 5th-Floor Rs. 10.78 Rs. 230.81 Rs. 241.59 per1sqm
F 6th-Floor Rs. 10.78 Rs. 267.35 Rs. 278.13 per1sqm
G 7th-Floor Rs. 10.78 Rs. 303.88 Rs. 314.66 per1sqm
H 8th-Floor Rs. 10.78 Rs. 340.43 Rs. 351.21 per1sqm
I 9th-Floor Rs. 10.78 Rs. 376.98 Rs. 387.76 per1sqm
J 10th-Floor Rs. 10.78 Rs. 413.51 Rs. 424.29 per1sqm
K 11th-Floor Rs. 10.78 Rs. 450.06 Rs. 460.84 per1sqm
L 12th-Floor Rs. 10.78 Rs. 486.61 Rs. 497.39 per1sqm

158
M 13th-Floor Rs. 10.78 Rs. 523.15 Rs. 533.93 per1sqm
N 14th-Floor Rs. 10.78 Rs. 559.68 Rs. 570.46 per1sqm
O 15th-Floor Rs. 10.78 Rs. 596.23 Rs. 607.01 per1sqm

HIRE CHARGES FOR ACCESS SCAFFOLDING - upto 3.66 M using Casurina Ballies, Bamboos,
Wooden Reapers,
Runners,WoodPosts,WallPlatesetc.,forPLASTERINGtoWALLS-1sqm

Centring
MaterialHire Labour Unitof
Sl NAMEOFTHESTRUCTURALMEMBER Chargesfor
charges charges Measurement
2018-19
1 2 3 4 5 6

A 1st-Floor Rs. 1.08 Rs. 8.47 Rs. 9.55 per1sqm


B 2nd-Floor Rs. 1.08 Rs. 12.12 Rs. 13.20 per1sqm
C 3rd-Floor Rs. 1.08 Rs. 15.77 Rs. 16.85 per1sqm
D 4th-Floor Rs. 1.08 Rs. 19.43 Rs. 20.51 per1sqm
E 5th-Floor Rs. 1.08 Rs. 23.08 Rs. 24.16 per1sqm
F 6th-Floor Rs. 1.08 Rs. 26.73 Rs. 27.81 per1sqm
G 7th-Floor Rs. 1.08 Rs. 30.38 Rs. 31.46 per1sqm
H 8th-Floor Rs. 1.08 Rs. 34.05 Rs. 35.13 per1sqm
I 9th-Floor Rs. 1.08 Rs. 37.70 Rs. 38.78 per1sqm
J 10th-Floor Rs. 1.08 Rs. 41.35 Rs. 42.43 per1sqm
K 11th-Floor Rs. 1.08 Rs. 45.01 Rs. 46.09 per1sqm
L 12th-Floor Rs. 1.08 Rs. 48.66 Rs. 49.74 per1sqm
M 13th-Floor Rs. 1.08 Rs. 52.31 Rs. 53.39 per1sqm
N 14th-Floor Rs. 1.08 Rs. 55.97 Rs. 57.05 per1sqm
O 15th-Floor Rs. 1.08 Rs. 59.62 Rs. 60.70 per1sqm

HIRECHARGESFORSTAGESCAFFOLDING-upto3.66MusingCasurinaBallies,
Bamboos,WoodenReapers,Runners,WoodPosts,WallPlatesetc.,forCEILINGPLAST
ERING-1sqm
A 1st-Floor Rs. 2.57 Rs. 16.94 Rs. 19.51 per1sqm

B 2nd-Floor Rs. 2.57 Rs. 24.04 Rs. 26.61 per1sqm


C 3rd-Floor Rs. 2.57 Rs. 31.13 Rs. 33.70 per1sqm
D 4th-Floor Rs. 2.57 Rs. 38.23 Rs. 40.80 per1sqm
E 5th-Floor Rs. 2.57 Rs. 45.33 Rs. 47.90 per1sqm
F 6th-Floor Rs. 2.57 Rs. 52.42 Rs. 54.99 per1sqm
G 7th-Floor Rs. 2.57 Rs. 59.52 Rs. 62.09 per1sqm
H 8th-Floor Rs. 2.57 Rs. 66.62 Rs. 69.19 per1sqm
I 9th-Floor Rs. 2.57 Rs. 73.72 Rs. 76.29 per1sqm
J 10th-Floor Rs. 2.57 Rs. 80.81 Rs. 83.38 per1sqm
K 11th-Floor Rs. 2.57 Rs. 87.91 Rs. 90.48 per1sqm
L 12th-Floor Rs. 2.57 Rs. 95.01 Rs. 97.58 per1sqm
M 13th-Floor Rs. 2.57 Rs. 102.03 Rs. 104.60 per1sqm
N 14th-Floor Rs. 2.57 Rs. 109.19 Rs. 111.76 per1sqm
O 15th-Floor Rs. 2.57 Rs. 116.30 Rs. 118.87 per1sqm

159
CENTERING&SCAFFOLDING CHARGES-FLOORWISERATES
forSteelscaffoldingpipes,jackProps,SteelCenteringPlates,etc.,forunsupported
height3.66M
SLA SLABS- WAFFLE PERGOL
ARCH ARCH SHEAR
CHAJJA BS- above1 SLABS- - A HELI
COLU BEA BEAM BEAM
FLOOR LINTELS S- Up 50mm above3 (GRID)SL SLAB S DOME CAL WALLS,
MNS MS S S SLAB RCC
SUNSH to15 - Up to 00 ABS (Only STAI
- up to -above S WALLS,
ADES 0 300 mmthic (Rib RibBe R-
mmthick ams ) 1.5 1.5 WATER
mm k Beamswit CAS
MSp MSp TANK
thic hSlabs) ES
k an an WALLS
Material Hirefor
H 1233 243 371 2179 247 254 265 897 629 2477 2512 4005 305 472
anyFloor
LabourCharges
510
for1st L 1720 264 2415 2027 241 248 260 834 585 2304 2336 3723 284
Floor
Total
T 2953 507 2786 4206 488 502 525 1731 1214 4781 4848 7728 589 982
HireCharges(H+
L)

1st- Floor L 1720 264 2415 2027 241 248 260 834 585 2304 2336 3723 284 510
2nd - Floor L 1892 290 2657 2230 265 273 286 917 644 2534 2570 4095 312 561
3rd - Floor L 2064 317 2898 2432 289 298 312 1001 702 2765 2803 4468 341 612

4th-Floor L 2236 343 3140 2635 313 322 338 1084 761 2995 3037 4840 369 663
5th-Floor L 2408 370 3381 2838 337 347 364 1168 819 3226 3270 5212 398 714
6th-Floor L 2580 396 3623 3041 362 372 390 1251 878 3456 3504 5585 426 765
7th-Floor L 2752 422 3864 3243 386 397 416 1334 936 3686 3738 5957 454 816
8th-Floor L 2924 449 4106 3446 410 422 442 1418 995 3917 3971 6329 483 867
9th-Floor L 3096 475 4347 3649 434 446 468 1501 1053 4147 4205 6701 511 918

10th -Floor L 3268 502 4589 3851 458 471 494 1585 1112 4378 4438 7074 540 969
11th -Floor L 3440 528 4830 4054 482 496 520 1668 1170 4608 4672 7446 568 1020
12th -Floor L 3612 554 5072 4257 506 521 546 1751 1229 4838 4906 7818 596 1071
13th -Floor L 3784 581 5313 4459 530 546 572 1835 1287 5069 5139 8191 625 1122
14th -Floor L 3956 607 5555 4662 554 570 598 1918 1346 5299 5373 8563 653 1173
15th -Floor L 4128 634 5796 4865 578 595 624 2002 1404 5530 5606 8935 682 1224

Note: -Centering&scaffoldingcharges forsteelscaffoldingwithpipes,jack


props,steelcentringplatesforunsupportedheightsofevery610mmheightabove3.66M,maybeallowedat16.666%more
thanthe basicmaterialhirechargesand relevantlabour chargesofthe applicablefloorand item

160
CENTERING&SCAFFOLDING CHARGES-FLOORWISERATES
forCasurinaBallies,Bamboos,WoodenReapers,Runners,WoodPosts,WallPlates,SteelCentringPlatesetc.,forunsupport
edheight3.66M
WAFFLE
SLABS- ARC
SLABS- SLABS - PERGOL ARCH
CHAJJA above HBE DOME
LINTEL COLUMN Up - (GRID)S ASLAB BEAM HELICALS
FLOOR S- BEAMS to150 150m AM SLABS
S S above LABS S S TAIRCASES
SUNSHA m S-
mmthic 300 (RibB (Only -above
DES - Up upto
k mmthic eams RibBea 1.5
to300 1.5M
k with ms) MSp
mmthic Slabs) Span
an
k

H
826 163 249 1458 165 170 178 601 421 1657 1681 2681 501
Material Hire
foranyFloor

Labour L
1332 204 1871 1569 186 193 201 646 453 1784 1808 2884 220
Chargesfor1st
Floor

Total T 2158 367 2120 3027 351 363 379 1247 874 3441 3489 5565 721
HireCharges
(H+L)

1st- Floor L 1332 204 1871 1569 186 193 201 646 453 1784 1808 2884 220

2nd - Floor L 1465 224 2058 1726 205 212 221 711 498 1962 1989 3172 242

3rd - Floor L 1598 245 2245 1883 223 232 241 775 544 2141 2170 3461 264

4th-Floor L 1732 265 2432 2040 242 251 261 840 589 2319 2350 3749 286

5th-Floor L 1865 286 2619 2197 260 270 281 904 634 2498 2531 4038 308

6th-Floor L 1998 306 2807 2354 279 290 302 969 680 2676 2712 4326 330

7th-Floor L 2131 326 2994 2510 298 309 322 1034 725 2854 2893 4614 352

8th-Floor L 2264 347 3181 2667 316 328 342 1098 770 3033 3074 4903 374

9th-Floor L 2398 367 3368 2824 335 347 362 1163 815 3211 3254 5191 396

10th - Floor L 2531 388 3555 2981 353 367 382 1227 861 3390 3435 5480 418
11th - Floor L 2664 408 3742 3138 372 386 402 1292 906 3568 3616 5768 440
12th - Floor L 2797 428 3929 3295 391 405 422 1357 951 3746 3797 6056 462
13th - Floor L 2930 449 4116 3452 409 425 442 1421 997 3925 3978 6345 484
14th - Floor L 3064 469 4303 3609 428 444 462 1486 1042 4103 4158 6633 506
15th - Floor L 3197 490 4490 3766 446 463 482 1550 1087 4282 4339 6922 528

161
Note:-

1) All Materials conforming to ISI orrelevant International


StandardsshallbeusedinallCIVIL,WaterSupply&SanitaryFittings,
ElectricalandElectro-MechanicalWorks.

2) Concerneddepartmentsshallapprovethematerialseitherfromthe
manufacturer or from its authorized /certified dealer only
andalsoto approve the brands of the products / materialsto
beadopted in their estimates at their end.In case common
approvalis required by the committee, concerned authority shall
proposewith all the details after thorough verification, to the
committee forconsidering theproposal.

3) SoR rates forCiviland Water supply & Sanitary items are


purelyforguidanceoftheofficersinpreparationofestimatesvidepara
113ofAPPWDCode.Authoritywhopreparestheestimateis,howeve
rresponsible for proper rates as envisaged in Para 45
ofAPPWDCode.

4) The rates published in the Buildings SoR 2021-22 are


theceilingratesonlyandtheestimatepreparingauthoritiesarerespon
sible for the correctness and reasonableness of the ratesand
technicalspecificationsadoptedintheestimates.

162
List of Recommended brands/Manufacturers for guidance of
field engineers :-
NOTE :
This list of popular/reputed brands/manufacturers is for guidance. The concerned Engineer
shall from time to time ensure their approval status with respect to quality / approvals from
standard institutions for adopting in the estimate of the works. The Engineer can exercise
his/her discretion in selection while using other than these listed brands on satisfaction of
their eligibility with respect to ISI or such standard institutional approvals ,quality ,durability
and record/reputation of that product.
Sl.
SECTION NAMES OF THE RECOMMENDED BRAND/ MANUFACTURER/ SUPPLIER
No
A SECTION BRICKS & BUILDING BLOCKS
III SUB-SECTION Aerocon, Siporex, Nucon, NCL Aerated Blocks
C SECTION WALL & FLOOR TILES
I SUB-SECTION NON-PORCELAIN CERAMIC FLOOR TILES - Somany, H & R Johnson, Naveen
Ceramics, Kajaria, Nitco, Sphinx, Orient Bell, AGL, Hindware, Cera, Varmora,
Vitero, Ambani, SUNHEARRT CERAMIK

II SUB-SECTION PORCELAIN VITRIFIED FLOOR TILES - H & R Johnson, H & R Johnson Marbonite,
H & R Johnson Endura, H & R Johnson GPS, Naveen Ceramics, Kajaria, Nitco, Orient
Bell, Hindware, AGL, RicasilCermaics Exxaro, Cera, Varmora, VITERO, Ambani,
SUNHEARRT CERAMIK
III SUB-SECTION CERAMIC WALL TILES - Somany, H & R Johnson, Kajaria, Sphinx, Orient Bell, AGL,
Hindware, RicasilCermaics Exxaro, Cera, Varmora, Vitero, Ambani, SUNHEARRT
CERAMIK
IV SUB-SECTION PORCELAIN WALL TILES - Somany, H & R Johnson, Kajaria, Sphinx, Orient Bell,
Hindware, Ricasil Cermaics Exxaro, Cera, Varmora, VITERO, Ambani, NCL Vitristik
for Ceramic vitrified tiles on floor, NCL Tilostik for fixing Granite stones and NCL
Marbostik for fixing Marble stones, SUNHEARRT CERAMIK
V SUB-SECTION GLASS MOSAIC TILES – Bisazza * Palladio * Expansive acqua reactive water
barrier grouting system – NCL Tile grout
VI SUB-SECTION WALL CLADDING TILES - Somany, H & R Johnson, Kajaria, Sphinx, Orient Bell,
Hindware, Cera, SUNHEARRT CERAMIK
D SECTION PAVING & INTERLOCKING TILES
I SUB-SECTION TERRAZZO FLOOR TILES (PLAIN & CHEQUERED) - Super Decorative, Aditya
Designer, Maha Bhima, Tricon, Pheonix, Eurocon, Ultra, Sphinx, Cemtech
II SUB-SECTION CEMENT CONRETE FLOOR TILES (PLAIN & CHEQUERED) - Super Decorative,
Aditya Designer, Maha Bhima, Tricon, Pheonix, Eurocon, Ultra, Sphinx
III SUB-SECTION PRE-CAST CONCRETE BLOCKS FOR PAVING - Super Decorative, Aditya Designer,
Maha Bhima, Tricon, Pheonix, Eurocon, Ultra, Sphinx, Cemtech, DEC Industries
PVT LTD, BMI Monier
IV SUB-SECTION VINYL FLOORING - Marblex, Amstrong
TILE ADHESIVE – MYK LATICRETE, Ambani, JK TileMaxX * Wall dado with cement
based adhesive – NCL Vitristik for Ceramic vitrified tiles * Cement based adhesive
– NCL Tilostik for fixing Granite stones and NCL Marbostik for fixing Marble
stones * Cement based Polymer modified jointing mortar – NCL Masonry glue *
Cement based Polymer modified plastering mortar – NCL Render
GLASS FIBRE REINFORCED CONCRETE TILES-ABC GRC Tiles
E SECTION TIMBER & ROOFING MATERIAL - DEC Industries PVT LTD
F SECTION STEEL MATERIALS - DEC Industries PVT LTD
G SECTION FIXTURES FOR DOORS & WINDOWS - Hardwyn, Godrej, Dorset, Dorma, Assa

163
Sl.
SECTION NAMES OF THE RECOMMENDED BRAND/ MANUFACTURER/ SUPPLIER
No
Abloy, M/s DEC Industries Pvt Ltd
H SECTION CONSTRUCTION CHEMICALS AND ADMIXTURES
I SUB-SECTION REPAIRING & TREATMENT WORKS
Armstrong / Fosroc ,PMCC, Asian LeakShield, M/S DEC Industries PVT LTD.
II SUB-SECTION INTEGRAL WATER PROOFING COMPOUNDS
TBSC-Q.II-01 Armstrong Chemicals Pvt Ltd Bengaluru , Fosroc Chemicals India Pvt Ltd
Bengaluru, Zoriproof No.1 of Protect More construction, PIDILITE INDUSTRIES
LIMITED,Sunanda Speciality Coatings Pvt Ltd, Asian Paints, M/S DEC Industries
PVT LTD.
III SUB-SECTION PLASTICIZERS
Armstrong Chemicals Pvt Ltd, Bengaluru, Fosroc Chemicals India Pvt Ltd,
Bengaluru, Zoriplax of Protect More Construction chemicals, Hyderabad *
BONDTUF CONSTRUCTION CHEMICALS , Sunanda Speciality Coatings Pvt Ltd ,
Asian Paints, M/S DEC Industries PVT LTD.
IV SUB-SECTION GROUTS
Armstrong Chemicals Pvt Ltd, Bengaluru, Fosroc Chemicals India Pvt Ltd,
Bengaluru, Protect More Construction Chemicals (Yield 0.5 Ltrs / 1 Kg Pack ),
M/S DEC Industries PVT LTD.
V SUB-SECTION BONDING AGENTS/ ADHESIVES
Armstrong Chemicals Pvt Ltd Bengaluru, Fosroc Chemical India Pvt Ltd
Bengaluru, Protect More Construction Chemicals. M/S DEC Industries PVT LTD.
VIII SUB-SECTION ANTI-CORROSIVE AGENTS
Armstrong Chemicals Pvt Ltd Bengaluru , Fosroc Chemicals India Pvt Ltd
Bengaluru, Protect More Construction Chemicals.( 40 SFT Per Ltr / Coat ) * CLEAN
TECH CORROSION , Protect More Construction Chemicals Hyderabad, M/S DEC
Industries PVT LTD.
I SECTION GLASS MATERIALS - Modifloat, Asahi, Saint-Gobain, Binani, HNG.
J SECTION PAINTS & POLISHES - Asian Paints, Berger, Nerolac, British Paints, JK Cements,
Nexon paints, Indocem, ESSAR, Sheenlac, Suryacem, Neon, Wallz, Walrus –
SYNTHETIC PLASTER - NCL-Cement Primer (Interior, Exterior), NCL White
Cement Putty, NCL-Alltek Spray Plaster, NCL-Skimcoat, Allteck Spray Plaster, NCL
Gaiety, NCL-Delight, NCL-Harmony, NCL-Alltek Dune, NCL Alltek Acrylic Coarse,
NCL Grey Coarse Putty, NCL Base Coat, NCL Flora, Allteck Deco Orient, MYK
LATICRETE, Multichem, Essar, JK ShieldMaxX - White Cement, JK WhiteMaxX,
LevelMaxX , JK GypsoMaxX , JK BondMaxX , Wall Putty (White cement based) JK
WallMaxX, JK Primaxx(White Cement Based Primer), Smoothtek, Shalimar,
Snowcem, Nippon, New World Paints Pvt. Ltd, Fortune Paints Pvt. Ltd, BAKELITE
COATINGS AND PAINTS, NCL Topcoat paint, Alltek Trendy, Alltek Goldline
K SECTION PARTICLE BOARDS - NCL Bison, Ramco-Hilux, Ramco-Hicem, Everest-board,
Visaka-board, Rajshri, Innsula, Birla Aerocon, Aerolite, Novopan, Bhutan-board,
Greenply, Greenpanel, Kajariaply, ECOBOARD
L SECTION PLYWOODS, LAMINATES & VENEERS - Kitply, Century Ply, National Ply, Bhutan
Ply, Samrat, Gurjan ply, Aamoda, Mayur, Amul Boards, Greenply, Greenpanel,
Kajariaply, PRAYAG POLYMERS, Archidply/ M/S DEC Industries PVT Ltd
M SECTION CEILINGS, WALL PARTITIONS & WALL LININGS -Ramco-Hilux, Everest-board,
Visakha-board, Rajshri, Innsula, Gypsum India, Saint-Gobain, Armstrong-Knauf
Ceilings, Daikin, NCL-Seccolor, NC Bison, Rock Strength, Aerolite, USG Boral, Birla
Aerocon, Diamond, Aerolite, DIAMOND FRAMES
N SECTION DOORS, SHUTTERS & FRAMES -NCL Buildtek, Anand, Raavila, Kutty, Standard,
Shubhdwar, ITP, Rajshri, NCL-Bison, Elixir, Sintex, Elgi, Oasis, Polywood, Sintex,
NCL Prelaminated ABS door shutter, NCL FPS Door Frame, , NCL-Veka, Fenesta, ,
Masonite, Everest, Vishaka, Ambience, Aamoda, Rehau,, Nandi PVC Doors, Aparna-
Venster, Ecoste, DEC Infrastructure & Projects(I) Pvt. Ltd, Ecocell, Marcolini,
Greenpanel, Kajariaply, HDHMR Doors – NCL, Yashpoly , ULTIMATE SAFETY
METAL DOORS, SUDHAKAR PROFILE SYSTEMS, SHREEJI WOODCRAFT PVT LTD,
DEC Industries PVT LTD , Galwin Techno Fab industries Pvt.Ltd

164
Sl.
SECTION NAMES OF THE RECOMMENDED BRAND/ MANUFACTURER/ SUPPLIER
No
SUB-SECTION UPVC DOORS AND WINDOWS : Sintex, NCL Veka, Fenesta, LG, ,Eumax by
EUREKA
Window systems pvt.ltd,, Sudhakar profile systems, REHAU
P SECTION WINDOWS - NCL-Buildtek, NCL-Bison, Elixir, Sintex, Elgi, Oasis, Polywood, NCL-
Veka, Fenesta, , Ahlada, Rehau, , Win-Eshtas-Viswajeet Industries, Aparna Venster,
ecoVUE, EcoCell, Yashpoly, Marcolini, , DEC Industries PVT LTD , Galwin Techno
Fab industries Pvt.Ltd
Q SECTION STRUCTURAL GLAZING & CURTAIN WALLING - NCL Buildtek, NCL-Bison,
Elixir, Sintex, Elgi, Oasis, Polywood, Sintex, NCL-Wintech, Fenesta, LG, Rehau,
Arpitha, , Galwin Techno Fab industries Pvt.Ltd
R SECTION MISCELLANEOUS ITEMS
(a) Sintex, Aquatech for PVC tanks
(b) Centurywells & Sudarshana for Galvalume sheets
(c) Elixir for PEB structures
(d) Aluminium Sections - Hindalco, Nalco, Jindal, Geetha series
(e)Gypsum plaster-NKV Home Depot, Gyplite,
(f) AC Sheets – Charminar Fortune
(g) MPC ( Mineral Polymer Composite) Grills/Jali – Esoste, Carpets – Welspun (i)
Polycarbonate sheets – DPI Daylighting
(h) Design, fabrication & supply of light weight pre engineered buildings - DEC
Industries PVT LTD, NCL Buildtek, Kirby

165
WATERSUPPLY
&
SANITARYITEMS

166
WATERSUPPLY&SANITARYITEMS
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
1 2 3 4 5
A S.W.G.PIPES&FITTINGS
Supplying, laying, jointing and testing 101.6 mm SWG SP-
1pipes of ISI make conforming to ISI 651 & 4127 with
1 MAT-01667 BMW-A.01 airtightcementjointsinCM1.5:1prop.Includingexcavationoftre 1RM
396
nches and socket pits in any soil (except rock
requiringblasting)upto1524mm(5'0")depthandrefillingwithwat
ering andtamping.
Supplying, laying, jointing and testing 101.6 mm SWG SP-
1pipes of ISI make conforming to ISI 651 & 4127 with
2 MAT-01668 BMW-A.02 airtightcementjointsinCM1:5:1prop.includingexcavationoftre 1RM
394
nches and socket pits in any soil (except rock
requiringblasting)upto914.4mm(3'0")depthandrefillingwithwa
tering andtamping.
Supplying, laying, jointing and testing 152.4 mm SWG SP-
1pipes of ISI make conforming to ISI 651 & 4127 with
3 MAT-01669 BMW-A.03 airtightcementjointsinCM1.5:1prop.includingexcavationoftre 1RM
586
nches and socket pits in any soil (except rock
requiringblasting)upto1524mm(5'0")depthandrefillingwithwat
ering andtamping.
Supplying, laying, jointing and testing 152.4 mm SWG SP-
1pipes of ISI make conforming to ISI 651 & 4127 with
4 MAT-01670 BMW-A.04 airtightcementjointsinCM1.5:1prop.includingexcavationoftre 1RM 576
nches and socket pits in any soil (except rock
requiringblasting)upto914.4mm(3'0"))depthandrefillingwithw
atering andtamping.
labour charges only for laying, jointing and testing
SWGpipesofanydiawithairtightcementjointsincludingexcavati
5 LAB-00411 BMW-A.05 onoftrenchesandsocketpitsinanysoilupto 1RM 246
914.4 mm (3'0") depth (except rock requiring blasting)
andrefillingwithwateringandtamping.
labour charges only for laying, jointing and testing
SWGpipesofanydiawithairtightcementjointsincludingexcavati
6 LAB-00412 BMW-A.06 onoftrenches andsocket pitsinanysoilupto1524mm(5'- 1RM 305
0")depth(exceptrockrequiringblasting)andrefillingwithwaterin
gandtamping.
a)Supplying, laying, jointing and testing 152.4 mmCC
7 MAT-01671 BMW-A.07 bed1:2:4Prop:using19.05mmgaugegradedgranitemetalchips 1RM 215
and cradling 101.6 mm SWG pipe line all round
tohave76.2mmthick coveroverthesockets.
8 LAB-00413 BMW-A.08 b)-do-labourchargesonly 1RM 10.5
a)Supplying , laying, jointing and testing 152.4 mmCC
9 MAT-01672 BMW-A.09 bed1:2:4Prop:using19.05mmgaugegradedgranitemetalchips 1RM 298
and cradling 152.4 mm SWG pipe line all round
tohave76.2mmthick coveroverthesockets.
10 LAB-00414 BMW-A.10 b)-do-labourchargesonly 1RM 52
a)Supplying&Laying101.6mmSWGchannelswithcement
11 MAT-01673 BMW-A.11 mortar joints with suitable brick masonry for 1RM 83
fixingthechannels inposition

167
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
12 LAB-00150 BMW-A.12 b)-do-labourchargesonly 1RM 39
a)Supplying&Laying152.4mmSWGchannelswithcement
13 MAT-01674 BMW-A.13 mortar joints with suitable brick masonry for 1RM 153
fixingthechannels inposition
14 LAB-00151 BMW-A.14 b)-do-labourchargesonly 1RM 54
SupplyofSWGSP-1PipeconformingtoISI651-4"dia(101.6mm)
15 MAT-01675 BMW-A.15 1RM 159

SupplyofSWGSP-1PipeconformingtoISI651-6"dia(152.4mm)
16 MAT-01676 BMW-A.16 1RM 277

SupplyofSWGSP-1PipeconformingtoISI651-8"dia(203.2mm)
17 MAT-01677 BMW-A.17 1RM 427

SupplyofSWGSP-1PipeconformingtoISI651-10"dia(254mm)
18 MAT-01678 BMW-A.18 1RM 782

SupplyofSWGSP-1PipeconformingtoISI651-12"dia(300mm)
19 MAT-01679 BMW-A.19 1RM 1127

SupplyofSWGSP-1PipeconformingtoISI651-14"dia(350mm)
20 MAT-01680 BMW-A.20 1RM 1534

SupplyofSWGSP-1PipeconformingtoISI651-16"dia(400mm)
21 MAT-01681 BMW-A.21 1RM 1849

SupplyofSWGSP-1PipeconformingtoISI651-18"dia(450mm)
22 MAT-01682 BMW-A.22 1RM 2233

SupplyofSWGSP-2PipeconformingtoISI651-4"dia(101.6mm)
23 MAT-01683 BMW-A.23 1RM 197

SupplyofSWGSP-2PipeconformingtoISI651-6"dia(152.4mm)
24 MAT-01684 BMW-A.24 1RM 292

SupplyofSWGSP-2PipeconformingtoISI651-8"dia(203.2mm)
25 MAT-01685 BMW-A.25 1RM 527

SupplyofSWGSP-2PipeconformingtoISI651-10"dia(254mm)
26 MAT-01686 BMW-A.26 1RM 829

SupplyofSWGSP-2PipeconformingtoISI651-12"dia(300mm)
27 MAT-01687 BMW-A.27 1RM 1273

SupplyofSWGSP-2PipeconformingtoISI651-14"dia(350mm)
28 MAT-01688 BMW-A.28 1RM 1650

SupplyofSWGSP-2PipeconformingtoISI651-16"dia(400mm)
29 MAT-01689 BMW-A.29 1RM 1901

SupplyofSWGSP-2PipeconformingtoISI651-18"dia(450mm)
30 MAT-01690 BMW-A.30 1RM 2426

SupplyofSWGSP-3PipeconformingtoISI651-4"dia(101.6mm)
31 MAT-01691 BMW-A.31 1RM 251

SupplyofSWGSP-3PipeconformingtoISI651-6"dia(152.4mm)
32 MAT-01692 BMW-A.32 1RM 365

SupplyofSWGSP-3PipeconformingtoISI651-8"dia(203.2mm)
33 MAT-01693 BMW-A.33 1RM 646

SupplyofSWGSP-3PipeconformingtoISI651-10"dia(254mm)
34 MAT-01694 BMW-A.34 1RM 982

168
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
SupplyofSWGSP-3PipeconformingtoISI651-12"dia(300mm)
35 MAT-01695 BMW-A.35 1RM 1372

SupplyofSWGSP-3PipeconformingtoISI651-14"dia(350mm)
36 MAT-01696 BMW-A.36 1RM 1742

SupplyofSWGSP-2PipeconformingtoISI651-16"dia(400mm)
37 MAT-01697 BMW-A.37 1RM 2005

SupplyofSWGSP-3PipeconformingtoISI651-18"dia(450mm)
38 MAT-01698 BMW-A.38 1RM 2728

SupplyofSWGBendsconformingtoISstandards-100mmdia
39 MAT-01699 BMW-A.39 Each 80

SupplyofSWGBendsconformingtoISstandards-150mmdia
40 MAT-01700 BMW-A.40 Each 148

SupplyofSWGBendsconformingtoISstandards-200mmdia
41 MAT-01701 BMW-A.41 Each 279

SupplyofSWGBendsconformingtoISstandards-250mmdia
42 MAT-01702 BMW-A.42 Each 566

SupplyofSWGBendsconformingtoISstandards-300mmdia
43 MAT-01703 BMW-A.43 Each 719

SupplyofSWGBendsconformingtoISstandards-350mmdia
44 MAT-01704 BMW-A.44 Each 898

SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
45 MAT-01705 BMW-A.45 Each 154
lengthof barrel60cm for- 100x100
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
46 MAT-01706 BMW-A.46 Each 227
lengthof barrel60cm for- 150x100
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
47 MAT-01707 BMW-A.47 Each 248
lengthof barrel60cm for- 150x150
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
48 MAT-01708 BMW-A.48 Each 353
lengthof barrel60cm for-200x 100
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
49 MAT-01709 BMW-A.49 Each 412
lengthof barrel60cm for- 200x150
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
50 MAT-01710 BMW-A.50 Each 473
lengthof barrel60cm for- 200x200
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
51 MAT-01711 BMW-A.51 Each 555
lengthof barrel60cm for- 250x100
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
52 MAT-01712 BMW-A.52 Each 733
lengthof barrel60cm for- 250x150
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
53 MAT-01713 BMW-A.53 Each 908
lengthof barrel60cm for- 250x200
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
54 MAT-01714 BMW-A.54 Each 1087
lengthof barrel60cm for- 250x250
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
55 MAT-01715 BMW-A.55 Each 792
lengthof barrel60cm for- 300x100
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
56 MAT-01716 BMW-A.56 Each 1015
lengthof barrel60cm for- 300x150
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswithl
57 MAT-01717 BMW-A.57 Each 1237
engthof barrel60cm for-300x 200

169
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
58 MAT-01718 BMW-A.58 Each 1460
lengthof barrel60cm for- 300x250
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
59 MAT-01719 BMW-A.59 Each 1683
lengthof barrel60cm for- 300x300
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
60 MAT-01720 BMW-A.60 Each 989
lengthof barrel60cm for- 350x100
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
61 MAT-01721 BMW-A.61 Each 1268
lengthof barrel60cm for- 350x150
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
62 MAT-01722 BMW-A.62 Each 1546
lengthof barrel60cm for- 350x200
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
63 MAT-01723 BMW-A.63 Each 1822
lengthof barrel60cm for- 350x250
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
64 MAT-01724 BMW-A.64 Each 2102
lengthof barrel60cm for- 350x300
SupplyofSWGJunctions(T's&Y's)conformingtoISstandardswith
65 MAT-01725 BMW-A.65 Each 2378
lengthof barrel60cm for- 350x350
SupplyofSWGPlugsconformingtoISstandardsfor100mmdia
66 MAT-01726 BMW-A.66 Each 29

SupplyofSWGPlugsconformingtoISstandardsfor150mmdia
67 MAT-01727 BMW-A.67 Each 55

SupplyofSWGPlugsconformingtoISstandardsfor200mmdia
68 MAT-01728 BMW-A.68 Each 106

SupplyofSWGPlugsconformingtoISstandardsfor250mmdia
69 MAT-01729 BMW-A.69 Each 183

SupplyofSWGPlugsconformingtoISstandardsfor300mmdia
70 MAT-01730 BMW-A.70 Each 290

SupplyofSWGPlugsconformingtoISstandardsfor350mmdia
71 MAT-01731 BMW-A.71 Each 364

Supplying&fixing150mmx100mmSWGgullytrapsconforming
to ISI 651 & 4127 with C.I Grating & Cost.Brick masonry in
72 MAT-01732 BMW-A.72 CM 1:6 prop. Intermediate chamber Each 508
andfittedwith304.8mmx288.6mm(12"x9")C.IFrameandhinge
dcover
SupplyofSWGGullyTraps(Round&Square)conformingtoISsta
73 MAT-01733 BMW-A.73 Each 229
ndards150x 100mm
Labour charges for fixing and laying the SWG
74 LAB-00152 BMW-A.74 Junctions/Plugs/ Bends of any dia with airtight cement joints Each 32
as perstandard practice
SupplyofSWGSaddlesconformingtoISstandards150x100
75 MAT-01734 BMW-A.75 Each 162
mm
SupplyofSWGSaddlesconformingtoISstandards200x100
76 MAT-01735 BMW-A.76 Each 279
mm
SupplyofSWGSaddlesconformingtoISstandards250x100
77 MAT-01736 BMW-A.77 Each 451
mm
MAN HOLES & INSPECTION CHAMBERS -AS PER -
B
IS4111 : Part 1: 1986

170
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Constructing904.0mm(3’0”)diasolidblockmasonryinspectionc
hamberasperIS-4111:Part-1:1986withcement mortar (1:6)
prop usingfly-ash blocks of 225
mmthickfromapprovedsourcehavingaminimumcrushingstren
gthof10N/sq.mmincludingplasteringwithcementmortar 1:3
prop; ½” thick both inside and outside fitted
with20”diaRCCmanholecoversandframesincludingexcavatin
78 MAT-05233 BMW-B.01 g pits up to a depth of 904 mm (3'-0") in all sorts ofsoils Each 5970
(excluding rock) and laying cement concrete(1:4:8)150 mm
thick using 40 mm HBG Metal and P.C.C.
1:2:4benchingandchannel100mmthickasperStandardspecifi
cationandincludingcostandconveyanceofallmaterialslikecem
ent,sand,bricks,wateretc.,tosite,costof seigniorage charges
on all materials and all incidentalandoperational, labour
charges like mixing cement mortar,constructing masonry, lift
charges, curing etc., complete forfinished itemofwork
asperStandardspecification.
Constructing904.0mm(3’0”)diasolidblockmasonryinspectionc
hamberasperIS-4111:Part-1:1986withcement mortar (1:6)
prop usingfly-ash blocks of 225
mmthickfromapprovedsourcehavingaminimumcrushingstren
gthof10N/sq.mmincludingplasteringwithcementmortar 1:3
prop; ½” thick both inside and outside fitted
with20”diaRCCmanholecoversandframesincludingexcavatin
79 MAT-05234 BMW-B.02 g pits up to a depth of 1524 mm (5'-0") in all sortsof soils Each 9395
(excluding rock) and laying cement concrete (1:4:8)150 mm
thick using 40 mm HBG Metal and P.C.C.
1:2:4benchingandchannel100mmthickasperStandardspecifi
cationandincludingcostandconveyanceofallmaterialslikecem
ent,sand,bricks,wateretc.,tosite,costof seigniorage charges
on all materials and all incidentalandoperational, labour
charges like mixing cement mortar,constructing masonry, lift
charges, curing etc., complete forfinished itemofwork
asperStandardspecification.
Constructing 904.0 mm (3’0”) dia brick masonry
inspectionchamber as per IS - 4111: Part-1:1986 with
cement mortar(1:6) prop using 2nd Class Clay Bricks of 225
mm thick fromapproved source having a minimum crushing
strength of
5N/sq.mmincludingplasteringwithcementmortar1:3prop;
½” thick both inside and outside fitted with 20” dia
80 MAT-05235 BMW-B.03 RCCmanholecoversandframesincludingexcavatingpitsuptoa Each 5783
depth of 904 mm (3'-0") in all sortsof soils
(excludingrock)andlayingcementconcrete(1:4:8)150mmthick
using 40 mm HBG Metal and P.C.C. 1:2:4 benching
andchannel100mmthickasperStandardspecificationandinclu
dingcostandconveyanceofallmaterialslikecement, sand,
bricks, water etc., to site, cost of seignioragecharges on all
materials and all incidental
andoperational,labourchargeslikemixingcementmortar,const
ructingmasonry, lift charges, curing etc., complete for
finished itemofwork as perStandardspecification.
Constructing 904.0 mm (3’0”) dia brick masonry
inspectionchamber as per IS - 4111: Part-1:1986 with
81 MAT-05236 BMW-B.04 cement mortar(1:6) prop using 2nd Class Clay Bricks of 225 Each 9033
mm thick fromapproved source having a minimum crushing
strength of
5N/sq.mmincludingplasteringwithcementmortar1:3prop;

171
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
½” thick both inside and outside fitted with 20” dia
RCCmanholecoversandframesincludingexcavatingpitsuptoa
depth of 1524 mm (5'-0") in all sorts of soils
(excludingrock)andlayingcementconcrete(1:4:8)150mmthick
using 40 mm HBG Metal and P.C.C. 1:2:4 benching
andchannel100mmthickasperStandardspecificationandinclu
dingcostandconveyanceofallmaterialslikecement, sand,
bricks, water etc., to site, cost of seignioragecharges on all
materials and all incidental
andoperational,labourchargeslikemixingcementmortar,const
ructingmasonry, lift charges, curing etc., complete for
finished itemofwork as perStandardspecification.
Constructing 914.4 mm x 457.2 mm (3'0"x1'6") brick in
82 MAT-01737 BMW-B.05 CM1:6prop.MasonryInspectionchamberupto914.4mm(3'0") Each 5630
and fitted with light weight 914.4 mm x 457.2
mm(3'0"x1'6")C.Iframeandcoverof40Kg.
Constructing 457.2 mm x 457.2 mm (1'6"x1'6") brick in
83 MAT-01738 BMW-B.06 CM1:6 prop.Masonry. Inspection chamber upto914.4 Each 3393
mm(3'0") and fitted with light weight 457.2 mm x 457.2
mm(1'6"x1'6")C.Iframeandcoverof20Kg.
a)Makingdrainageconnectionintheexistinginspectionincludingal
84 MAT-01739 BMW-B.07 Each 112
lrepairs
85 LAB-00157 BMW-B.08 b)-do-labourchargesonly Each 75
C.I. PIPES & FITTINGS -AS PER - IS 1729:1979
C (MaterialsshallbeprocuredfromthelistofapprovedBrands/Man
ufacturers/Suppliers)
Supplying and fixing of C.I. Single/ Double Socket soil
pipesISI marked conforming to IS:1729-1979 of reputed
makewithcementcaulkedjointsandfixingaspersiterequirement
s including painting black with Japan paint andfixing with
necessary wooden blocks fixed in the masonrywalls in
cement mortar (1½:1) and including fixing of M.S.clamps if
necessary with required no. of Bombay nails etc.,complete

86 MAT-01740 BMW-C.01 3"dia (76.2mm)Single Socket 1RM 711


87 MAT-01741 BMW-C.02 4"dia(101.6mm)SingleSocket 1RM 922
88 MAT-01742 BMW-C.03 6"dia(152.4mm)SingleSocket 1RM 1455
89 MAT-01743 BMW-C.04 3"dia (76.2mm)DoubleSocket 1RM 773
90 MAT-01744 BMW-C.05 4"dia(101.6mm)DoubleSocket 1RM 1021
91 MAT-01745 BMW-C.06 6"dia(152.4mm)DoubleSocket 1RM 1669
Labour charges only forfixing of C.I. Single/ Double
Socketsoil pipes of any dia with cement caulked joints and
92 LAB-00158 BMW-C.07 fixing asper site requirements including painting black with 1RM 241
Japanpaint and fixing with necessary wooden blocks fixed
in themasonry walls in cement mortar and including fixing of
M.S.clampsifnecessary withrequirednails
Supplying & fixing CIPlain bends Ist quality ISI
93 MAT-01746 BMW-C.08 markedconforming to IS:1729-1979 with cement caulked Each 275
joints andfixing as per site requirements with standard
practice for3"dia(76.2mm)

172
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplying & fixing CIPlain bends Ist quality ISI
94 MAT-01747 BMW-C.09 markedconforming to IS:1729-1979 with cement caulked Each 345
joints andfixing as per site requirements with standard
practice for4"dia(101.6mm)
Supplying & fixing CIPlain bends Ist quality ISI
95 MAT-01748 BMW-C.10 markedconforming to IS:1729-1979 with cement caulked Each 565
joints andfixing as per site requirements with standard
practice for6"dia(152.4mm)
Supplying&fixingCIPlug(Door)bendsIstqualityISImarked
96 MAT-01749 BMW-C.11 conforming to IS:1729-1979 with cement Each 337
caulkedjointsandfixingaspersiterequirementswithstandardpr
acticefor3" dia(76.2mm)
Supplying&fixingCIPlug(Door)bendsIstqualityISImarked
97 MAT-01750 BMW-C.12 conforming to IS:1729-1979 with cement Each 415
caulkedjointsandfixingaspersiterequirementswithstandardpr
acticefor4" dia(101.6mm)
Supplying&fixingCIPlug(Door)bendsIstqualityISImarked
98 MAT-01751 BMW-C.13 conforming to IS:1729-1979 with cement Each 894
caulkedjointsandfixingaspersiterequirementswithstandardpr
acticefor6" dia(152.4mm)
Labour charges only for fixing CI Plain/ Plug (Door)
99 LAB-00159 BMW-C.14 bendswithcementcaulkedjointsandfixingaspersiterequireme Each 76
ntswithstandardpractice
Supplying and fixing of 76.2 mm (3") CI soil single
100 MAT-01752 BMW-C.15 junctionwith plug : conforming to IS:1729-1979 with cement Each 427
caulkedjointsandfixing
Supplying and fixing of 101.6 mm (4") CI soil single
101 MAT-01753 BMW-C.16 junctionwith plug : conforming to IS:1729-1979 with cement Each 658
caulkedjointsandfixing
Supplying and fixing of 152.4 mm (6") CI soil single
102 MAT-01754 BMW-C.17 junctionwith plug : conforming to IS:1729-1979 with cement Each 1537
caulkedjointsandfixing
Supplying and fixing of 76.2 mm (3") CI soil plain
103 MAT-01755 BMW-C.18 singlejunction : conforming to IS:1729-1979 with cement Each 361
caulkedjointsandfixing
Supplying and fixing of 101.6 mm (4") CI soil plain
104 MAT-01756 BMW-C.19 singlejunction : conforming to IS:1729-1979 with cement Each 487
caulkedjointsandfixing
Supplying and fixing of 152.4 mm (6") CI soil plain
105 MAT-01757 BMW-C.20 singlejunction : conforming to IS:1729-1979 with cement Each 1149
caulkedjointsandfixing
LabourchargesonlyfixingCIsoilsinglejunctionswithcement
106 LAB-00160 BMW-C.21 caulked joints and fixing as per site Each 107
requirementswithstandardpractice
Supplying and Fixing of 76.2 mm (3") CI soil Double
107 MAT-01758 BMW-C.22 junctionwith plug : conforming to IS:1729-1979 with cement Each 640
caulkedjointsandfixing
SupplyingandFixingof101.6mm(4")CIsoilDoublejunction with
108 MAT-01759 BMW-C.23 plug : conforming to IS:1729-1979 with cementcaulkedjoints Each 774
andfixing

173
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
SupplyingandFixingof152.4mm(6")CIsoilDoublejunction with
109 MAT-01760 BMW-C.24 plug : conforming to IS:1729-1979 with cementcaulkedjoints Each 1789
andfixing
Supplying and Fixing of 76.2 mm (3") CI soil plain
110 MAT-01761 BMW-C.25 Doublejunction : conforming to IS:1729-1979 with cement Each 555
caulkedjointsandfixing
Supplying and Fixing of 101.6 mm (4") CI soil plain
111 MAT-01762 BMW-C.26 Doublejunction : conforming to IS:1729-1979 with cement Each 724
caulkedjointsandfixing
Supplying and Fixing of 152.4 mm (6") CI soil plain
112 MAT-01763 BMW-C.27 Doublejunction : conforming to IS:1729-1979 with cement Each 1677
caulkedjointsandfixing
LabourchargesonlyfixingCIsoilDoublejunctionswithcement
113 LAB-00161 BMW-C.28 caulked joints and fixing as per site Each 107
requirementswithstandardpractice
SupplyingandFixingof75mmC.I.OffsetsIstqualityconforming
114 MAT-01764 BMW-C.29 to IS:1729-1979 with cement caulked joints andfixing- Each 271
for76.20mm(3") C.I.Pipe
SupplyingandFixingof75mmC.I.OffsetsIstqualityconforming
115 MAT-01765 BMW-C.30 to IS:1729-1979 with cement caulked joints andfixing- Each 377
for101.6mm(4") C.I.Pipe
SupplyingandFixingof75mmC.I.OffsetsIstqualityconforming
116 MAT-01766 BMW-C.31 to IS:1729-1979 with cement caulked joints andfixing- Each 813
for152.4mm(6") C.I.Pipe
SupplyingandFixingof115mmC.I.OffsetsIstqualityconforming
117 MAT-01767 BMW-C.32 to IS:1729-1979 with cement caulked joints andfixing- Each 322
for76.20mm(3")C.I.Pipe
SupplyingandFixingof115mmC.I.OffsetsIstqualityconforming
118 MAT-01768 BMW-C.33 to IS:1729-1979 with cement caulked joints andfixing- Each 425
for101.6mm(4")C.I.Pipe
SupplyingandFixingof115mmC.I.OffsetsIstqualityconforming
119 MAT-01769 BMW-C.34 to IS:1729-1979 with cement caulked joints andfixing- Each 833
for152.4mm(6")C.I.Pipe
SupplyingandFixingof150mmC.I.OffsetsIstqualityconforming
120 MAT-01770 BMW-C.35 to IS:1729-1979 with cement caulked joints Each 371
andfixingfor76.20mm(3") C.I.Pipe
SupplyingandFixingof150mmC.I.OffsetsIstqualityconforming
121 MAT-01771 BMW-C.36 to IS:1729-1979 with cement caulked joints Each 478
andfixingfor101.6mm(4") C.I.Pipe
SupplyingandFixingof150mmC.I.OffsetsIstqualityconforming
122 MAT-01772 BMW-C.37 to IS:1729-1979 with cement caulked joints Each 967
andfixingfor152.4mm(6") C.I.Pipe
LabourchargesonlyfixingCIsoilOffsetswithcementcaulkedjoin
123 LAB-00162 BMW-C.38 tsandfixingaspersiterequirementswithstandard practice Each 48

Supplying&fixingCIfloortraps1stqualityISImarkedconformingt
o IS:1729-1979 with C.P. Grating fixing
124 MAT-01773 BMW-C.39 withwhitecementaspersiterequirementswithstandardpractice Each 487
for nominal dia 75 mm (3") and grating size 165 mmdia
ofweightnot less than5.5Kgs

174
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplying&fixingCIfloortraps1stqualityISImarkedwith
C.P.Gratingfixingwithwhitecementaspersiterequirements
125 MAT-01774 BMW-C.40 with standard practicefornominal dia 100 mm(4") and Each 595
grating size 100 mm dia of weight not less than 6Kgs

Supplying&fixingCIfloortraps1stqualityISImarkedconformingt
o IS:1729-1979 with C.P. Grating fixing
126 MAT-01775 BMW-C.41 withwhitecementaspersiterequirementswithstandardpractice Each 302
for nominal dia 75 mm (3") and grating size 100 mmdia
ofweightnot less than4.0Kgs
LabourchargesonlyforfixingCINahany/Floortrapswith
127 LAB-00163 BMW-C.42 C.P.Gratingfixingwithwhitecementaspersiterequirementswithst Each 53
andardpractice
128 MAT-01776 BMW-C.43 BoxingofNahanytrapsinRCCfloors Each 168
129 MAT-01777 BMW-C.44 BoxingofW.CTrap inR.C.Cfloors Each 337
Supplying & fixing CI Collars (double socket) Ist quality
130 MAT-01778 BMW-C.45 ISImarked conforming to IS:1729-1979 with cement Each 160
caulkedjointsandfixingaspersiterequirementswithstandardpr
acticefor76.20mm(3")C.I.Pipe
Supplying & fixing CI Collars (double socket) Ist quality
131 MAT-01779 BMW-C.46 ISImarked conforming to IS:1729-1979 with cement Each 201
caulkedjointsandfixingaspersiterequirementswithstandardpr
acticefor101.6mm(4")C.I.Pipe
Supplying & fixing CI Collars (double socket) Ist quality
132 MAT-01780 BMW-C.47 ISImarked conforming to IS:1729-1979 with cement Each 578
caulkedjointsandfixingaspersiterequirementswithstandardpr
acticefor152.4mm(6")C.I.Pipe
VITREOUSCHINAWARE-SANITARYAPPLIANCESas
D per IS:2556–1974 (Materialsshallbeprocured from the
listofapproved Brands/Manufacturers/Suppliers)
Supplying&FixingIndianpatternwhiteglazedW.C1stqualityISI
133 MAT-01781 BMW-D.01 markedconformingtoIS:2556-Part-3-1981with"P"or"S" Each 979
trap:580 mmLong
Supplying&FixingIndianpatternwhiteglazedW.C1stqualityISI
134 MAT-01782 BMW-D.02 markedconformingtoIS:2556-Part-3-1981with"P"or"S" Each 979
trap:630 mmLong
LabourchargesonlyforfixingIndianpatternW.Cwith"P"or"S"tra
135 LAB-00164 BMW-D.03 Each 320
p
Supplying & Fixing Orissa Pan white glazed W.C 1st
136 MAT-01783 BMW-D.04 qualityISI marked conforming toIS:2556-Part-3-1981with"P" Each 1466
or"S"trap:580mmx 440mm
Supplying & Fixing Orissa Pan white glazed W.C 1st
137 MAT-01784 BMW-D.05 qualityISI marked conforming toIS:2556-Part-3-1981with"P" Each 1537
or"S"trap:630mmx 450mm
LabourchargesonlyFixingOrissapanW.Cwith"P"or"S"trap
138 LAB-00165 BMW-D.06 Each 400

Supplying & Fixing porcelain foot rest for squatting


139 MAT-01785 BMW-D.07 I.W.C.(Rectangular pair) of sizes 250 mm x 125 mm x 15 Pair 225
mm thickeach foot rest 1st quality ISI marked conforming to
IS:2556-Part-10:1974

175
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Labourchargesonlyforfixingporcelainfootrestforsquatting
140 LAB-00166 BMW-D.08 Pair 73
I.W.C.(Rectangularpair)
ProvidingBrickmasonryseatforOrissapan/IndianW.C.using
141 MAT-01786 BMW-D.09 Each 289
2nd class bricksas perstandardpractice
ProvidingCementConcreteSquattingplateforOrissapan/India
142 MAT-01787 BMW-D.10 Each 86
n W.C. in P.C.C.1:2:4 asperstandard practice
Supplying&Fixinglowdownporcelainflushingtank10LitCapacit
143 MAT-01788 BMW-D.11 Each 2333
ywith internalcomponents
Labourchargesonlyforfixinglowdownporcelainflushingtankwit
144 LAB-00167 BMW-D.12 Each 560
hinternalcomponents
Supplying and Fixing European Water Closet of 1st
145 MAT-01789 BMW-D.13 qualityconformingtoIS:2556-Part-2- Each 1870
1973ofwhiteglazedwith'P'trap
Supplying and Fixing European Water Closet of 1st
146 MAT-01790 BMW-D.14 qualityconformingtoIS:2556-Part-2- Each 1785
1973ofwhiteglazedwith'S'trap
LabourchargesonlyforfixingEuropeanWaterClosetwith'P'or
147 LAB-00168 BMW-D.15 Each 280
'S'trapasperstandardpractice
SupplyingandFixingbestIndianmakeplasticseatandlidfor
148 MAT-01791 BMW-D.16 European water closets with rubber or plastic Buffers Each 803
asperIS2548-1996
LabourchargesonlyforfixingplasticseatandlidforEuropean
149 LAB-00169 BMW-D.17 Each 81
watercloset
Supply, Installation and commissioning approved make
floormounted Close coupled EWC suitCASCADE model 'P'
or'S'trapwithdualflushporcelaincisternfixedonEWCwithall
150 MAT-01792 BMW-D.18 internal parts of dual flush cistern, ultra solid seatcoverof Each
8656
approvedmake with rubber buffer and cap 15 mm
anglestopcock450mmlongPVCinterconnectionpipewallflang
es all of approved make etc. complete for finished
itemofwork inallrespects:WhiteColour
Supply, Installation and commissioning approved make
floormountedClosecoupledEWCsuitCASCADEmodel'P'or'S't
rapwithdualflushporcelaincisternfixedonEWCwithall internal
151 MAT-01793 BMW-D.19 parts of dual flush cistern, ultra solid seatcoverof Each
12622
approvedmake with rubber buffer and cap 15 mm
anglestopcock450mmlongPVCinterconnectionpipewallflang
es all of approved make etc. complete for finished
itemofworkinallrespects:Coloured-Grade- I/Grade- II
Supply, Installation and commissioning approved make
floormounted close coupled EWC suit CASCADE model 'P'
or 'S'trap with dual flush porcelain cistern fixed on EWC with
152 MAT-01794 BMW-D.20 allinternal parts of dual flush cistern, ultra solid seat cover Each
16062
ofapprovedmake with rubber bufferand cap 15 mm
anglestopcock450mmlongPVCinterconnectionpipewallflang
es all of approved make etc. complete for finished
itemofworkinallrespects:SpecialColour-Grade-III
Supplying&FixingIndianmakeFlatBackWashHandBasin1stqu
153 MAT-01795 BMW-D.21 alityconformingtoIS:2556-Part- Each
4:1972withwastefittingslikerubberplug,chain,32mmnominalsi 2468
ze
C.P.FittingwithparallelpipethreadconformingtoIS:2963-

176
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
1979 and fitted with 15 mm nominal bore Chromium
PlatedPillarTapof1stqualityIndianmake400gramsSeiko/Seni
or/ Nice/ Esso or equivalent complete with standard
CIbracketsincludingwoodenblock:660x460mm-Single
C.P.Pillarcock
Supplying&FixingIndianmakeFlatBackWashHandBasin1stqu
alityconformingtoIS:2556-Part-
4:1972withwastefittingslikerubberplug,chain,32mmnominalsi
ze
154 MAT-01796 BMW-D.22 C.P. Fitting with parallel pipe thread conforming to IS:2963- Each
2191
1979 and fitted with 15 mm nominal bore Chromium
PlatedPillarTapof1stqualityIndianmake400gramsSeiko/Seni
or/ Nice/ Esso or equivalent complete with standard
CIbracketsincludingwoodenblock:630x450mm-Single
C.P.Pillarcock
Supplying&FixingIndianmakeFlatBackWashHandBasin1stqu
alityconformingtoIS:2556-Part-
4:1972withwastefittingslikerubberplug,chain,32mmnominalsi
ze
155 MAT-01797 BMW-D.23 C.P. Fitting with parallel pipe thread conforming to IS:2963- Each
2673
1979 and fitted with 15 mm nominal bore Chromium
PlatedPillarTapof1stqualityIndianmake400gramsSeiko/Seni
or/ Nice/ Esso or equivalent complete with standard
CIbracketsincludingwoodenblock:630x450mm-Double
C.P.Pillarcock
Supplying&FixingIndianmakeFlatBackWashHandBasin1stqu
alityconformingtoIS:2556-Part-
4:1972withwastefittingslikerubberplug,chain,32mmnominalsi
ze
156 MAT-01798 BMW-D.24 C.P. Fitting with parallel pipe thread conforming to IS:2963- Each
1641
1979 and fitted with 15 mm nominal bore Chromium
PlatedPillarTapof1stqualityIndianmake400gramsSeiko/Seni
or/ Nice/ Esso or equivalent complete with standard
CIbracketsincludingwoodenblock:550x400mm-Single
C.P.Pillarcock
Supplying&FixingIndianmakeFlatBackWashHandBasin1stqu
alityconformingtoIS:2556-Part-
4:1972withwastefittingslikerubberplug,chain,32mmnominalsi
ze
157 MAT-01799 BMW-D.25 C.P. Fitting with parallel pipe thread conforming to IS:2963- Each
1985
1979 and fitted with 15 mm nominal bore Chromium
PlatedPillarTapof1stqualityIndianmake400gramsSeiko/Seni
or/ Nice/ Esso or equivalent complete with standard
CIbracketsincludingwoodenblock:550x400mm-Double
C.P.Pillarcock
Supplying&FixingIndianmakeFlatBackWashHandBasin1stqu
alityconformingtoIS:2556-Part-
4:1972withwastefittingslikerubberplug,chain,32mmnominalsi
ze
158 MAT-01800 BMW-D.26 C.P. Fitting with parallel pipe thread conforming to IS:2963- Each
1436
1979 and fitted with 15 mm nominal bore Chromium
PlatedPillarTapof1stqualityIndianmake400gramsSeiko/Seni
or/ Nice/ Esso or equivalent complete with standard
CIbracketsincludingwoodenblock:450x300mm-Single
C.P.Pillarcock
Supplying&FixingIndianmakeFlatBackWashHandBasin1stqu
159 MAT-01801 BMW-D.27 alityconformingtoIS:2556-Part- Each
4:1972withwastefittingslikerubberplug,chain,32mmnominalsi 1849
ze
C.P.FittingwithparallelpipethreadconformingtoIS:2963-

177
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
1979 and fitted with 15 mm nominal bore Chromium
PlatedPillarTapof1stqualityIndianmake400gramsSeiko/Seni
or/ Nice/ Esso or equivalent complete with standard
CIbracketsincludingwoodenblock:450x300mm-Double
C.P.Pillarcock
Labour charges only for fixing Indian makeFlat Back
160 LAB-00170 BMW-D.28 WashHandBasinwithwastefittingslikerubberplug,chain,32m Each 338
mnominal size C.P. Fitting Pillar Taps complete with
standardCIbrackets includingwoodenblock
SupplyingandFixingPedestalforWashHandBasin(H.S.W
161 MAT-01802 BMW-D.29 Each 1136
/Parry/Earthenware)
162 LAB-00171 BMW-D.30 Labourcharges onlyforfixingpedestalforwashhand basin Each 144
Supplying&Fixing31.75mmC.Pbottletrap(Heavytype)Parryw
163 MAT-01803 BMW-D.31 Each 409
areorequivalent
Labourchargesonlyforfixingbottletraptothewashhandbasin
164 LAB-00172 BMW-D.32 Each 48

Supplying&FixingwhiteglazedflatbackBowlurinalsofsize 440
165 MAT-01804 BMW-D.33 mm x 265 mm x 315 mm with internal flushing Each 849
rimfixedwithscrewscompleteIndianmakeconformingtoIS:255
6-1995
Supplying& Fixing whiteglazed flat backhalfstallurinals1st
quality conforming to IS:2556-1995 with standard
166 MAT-01805 BMW-D.34 C.P.Spreader of overall size 95 x 95 x 57 mm conforming Each 2499
toIS:2556-Part6,Sec-6-1974fixedwithscrewscompleteIndian
make:410x265x305mm
Supplying& Fixing whiteglazed flat backhalfstallurinals1st
quality conforming to IS:2556-1995 with standard
167 MAT-01806 BMW-D.35 C.P.Spreader of overall size 95 x 95 x 57 mm conforming Each 2774
toIS:2556-Part6,Sec-6-1974fixedwithscrewscompleteIndian
make:590x375x390mm
LabourchargesonlyFixingflatbackBowl/Halfstallurinalswith
168 LAB-00173 BMW-D.36 Each 135
fixingC.P.Spreaderandscrewscomplete
Supplying & Fixing Indian make white glazed vitreous
chinaporcelainsinkconformingtoIS:2556-Part-5-
169 MAT-01807 BMW-D.37 1994oncantileverbracketswithwastefittingslikerubberplug,ch Each 4526
ain,32mmnominalsizeC.P.Fittingwithparallelpipethreadconfo
rmingto IS:2963-1979: 600x400 x250
Supplying & Fixing Indian make white glazed vitreous
chinaporcelainsinkconformingtoIS:2556-Part-5-
170 MAT-01808 BMW-D.38 1994oncantileverbracketswithwastefittingslikerubberplug,ch Each 5077
ain,32mmnominalsizeC.P.Fittingwithparallelpipethreadconfo
rmingto IS:2963-1979: 750x450 x250
Labour charges only for fixing Vitreous china porcelain
171 LAB-00174 BMW-D.39 sinkswith waste fittings, rubber plug, chain, cantilever Each 338
bracketsetc.
a) S & F 609.6 x 457.2 x 254 mmRCC terrazzo
172 MAT-01809 BMW-D.40 finishedsink(or constructed at sitewith 50.8mmthick) brass Each 738
plugandchainincludingCIcantileverbrackets
173 LAB-00175 BMW-D.41 b)-do-labourchargesonly Each 239

178
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
TAPS&FAUCETS(Materialsshallbeprocuredfromthelistofapp
E
roved Brands/Manufacturers/Suppliers)
MAT-01810 a)S &F12.7 mmNPstop cockIndianmakeheavyduty
174 BMW-E.01 Each 425

LAB-00176 b)-do-labourchargesonly
175 BMW-E.02 Each 31

MAT-01811 a)S&Fconcealedstopcock12.7mm(1/2")IndianMakeheavydut
176 BMW-E.03 Each 487
y
LAB-00177 b)-do-labourchargesonly
177 BMW-E.04 Each 46

MAT-01812 a)S&Fanglestopcock12.7mmdiafirstqualityIndianMakeheavy
178 BMW-E.05 Each 428
duty
LAB-00178 b)-do-labourchargesonly
179 BMW-E.06 Each 46

MAT-01813
180 BMW-E.07 a)S&F12.7mmN.Pbibtap(Long body) Indianmakeheavydutys Each 366

LAB-00179 b)-do-labourchargesonly
181 BMW-E.08 Each 31

MAT-01814 a)S&F 12.7mmN.Pbibtap(Short body) Indian makeheavyduty


182 BMW-E.09 Each 234

LAB-00180 b)-do-labourchargesonly
183 BMW-E.10 Each 31

MAT-01815 a)S&F31.75mmbrassplumberUnionbestIndianfirstquality
184 BMW-E.11 Each 64

LAB-00181 b)-do-labourchargesonly
185 BMW-E.12 Each 15

MAT-01816 a)S &F12.7 mmbrassstopcock(Long body) Indian


186 BMW-E.13 Each 210
makeheavyduty
LAB-00182 b)-do-labourchargesonly
187 BMW-E.14 Each 31

MAT-01817 a)S &F12.7 mmbrassstopcock (Short body)Indian


188 BMW-E.15 Each 185
makeheavyduty
LAB-00183 b)-do-labourchargesonly
189 BMW-E.16 Each 31

MAT-01818 a)S &F12.7mmbrassbib cock (Long


190 BMW-E.17 Each 210
body)Indianmakeheavyduty
LAB-00184 b)-do-labourchargesonly
191 BMW-E.18 Each 31

MAT-01819 a)S &F12.7mm brassbib cock( Short body)


192 BMW-E.19 Each 185
Indianmakeheavyduty
LAB-00185 b)-do-labourchargesonly
193 BMW-E.20 Each 31

MAT-01820 S&FCPLongbodybibcockfancytypedeluxeheavyduty
194 BMW-E.21 Each 573
12.7mmdiaIndianmake
S&FCPShortbodybibcockfancytypedeluxeheavyduty
195 MAT-01821 BMW-E.22 Each 550
12.7mmdiaIndianmake

179
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
S&F12.7mmheavydutydiahighneckpillarcock1stqualityIndian
196 MAT-01822 BMW-E.23 Each 1042
make
197 MAT-01823 BMW-E.24 a)S&F12.7mmheavydutyNPSwan NeckPillarcock Each 1042
LAB-00186 b)-do-labourchargesonly
198 BMW-E.25 Each 43

MAT-01824 a)S&F12.7mmheavydutyNPSinkcock
199 BMW-E.26 Each 1040

LAB-00187 b)-do-labourchargesonly
200 BMW-E.27 Each 37

S&F12.7mmdiaNPpillarcockheavydutyIstqualityIndian make
201 MAT-01825 BMW-E.28 Each 547

202 MAT-01826 BMW-E.29 S&F 12.7mmdiaNPpush cockIstquality Each 245


203 MAT-01827 BMW-E.30 S&F 12.7mmdiaNPliftcockIstquality Each 215
a)S&F38.1mmC.PwastecouplingHalforFullThread1stQualityI
204 MAT-01828 BMW-E.31 Each 215
ndianmakeParrywareorequivalent
205 LAB-00188 BMW-E.32 b)-do-labourchargesonly Each 31
206 MAT-01829 BMW-E.33 a)S &F31.75 mm PVCbottletrap Each 131
207 LAB-00189 BMW-E.34 b)-do-labourchargesonly Each 31
208 MAT-01830 BMW-E.35 a)S&F38.1mmbrassplumberunion Each 64
209 LAB-00190 BMW-E.36 b)-do-labourchargesonly Each 15
a)S&F19.05mmheavydutyNPstopcockIndianmakewith
210 MAT-01831 BMW-E.37 Each 547
ISImark
211 LAB-00191 BMW-E.38 b)-do-labourchargesonly Each 31
G.I.PIPES&FITTINGS(Materialsshallbeprocuredfromthelisto
F
fapprovedBrands/Manufacturers/ Suppliers)
212 MAT-01832 BMW-F.01 S&FGIunion 12.7mmIst Quality Each 40
213 MAT-01833 BMW-F.02 S&FGIunion 19.05mmIst Quality Each 48
214 MAT-01834 BMW-F.03 S&FGIunion 25.4mmIst Quality Each 73
215 MAT-01835 BMW-F.04 S&FGIunion31.75 mmIst Quality Each 90
216 MAT-01836 BMW-F.05 S&FGIunion 38.1mmIst Quality Each 108
217 MAT-01837 BMW-F.06 S&FGIunion 50.8mmIst Quality Each 134
218 MAT-01838 BMW-F.07 S&FGI connector25.4mmdia Each 80
219 MAT-01839 BMW-F.08 S&F12.7mmGI'T'A classIstquality Each 49
220 MAT-01840 BMW-F.09 S&F31.75mmdiaGI bendIstquality Each 73
221 MAT-01841 BMW-F.10 S&F31.75mm dia GI'T'1stQuality Each 72
a) S & F25.4mm copperballcockith
222 MAT-01842 BMW-F.11 Each 423
PVCballIndianmakeISImark
223 LAB-00192 BMW-F.12 b)-do-labourchargesonly Each 47
a)S&F19.05mm copperballcockithPVCball
224 MAT-01843 BMW-F.13 Each 347
IndianmakeISImark
225 LAB-00193 BMW-F.14 b)-do-labourchargesonly Each 43

180
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
a)S&F12.7mmcopperballcockithPVCballIndianmakeISImark
226 MAT-01844 BMW-F.15 Each 228

227 LAB-00194 BMW-F.16 b)-do-labourchargesonly Each 47


a)S&FGunmetalGate(GMpeet)valveasperIS-778Class -
228 MAT-01845 BMW-F.17 Each 1101
I,Indian makeheavytype-25mmNBSize
229 LAB-00195 BMW-F.18 b)-do-labourchargesonly Each 47
MAT-01846 a)S&FGunmetalGate(GMpeet)valveasperIS-778Class -
230 BMW-F.19 Each 768
I,Indian makeheavytype-20mmNBSize
231 LAB-00196 BMW-F.20 b)-do-labourchargesonly Each 47
a)S&FGunmetalGate(GMpeet)valveasperIS-778Class -
232 MAT-01847 BMW-F.21 Each 571
I,Indian makeheavytype-15mmNBSize
233 LAB-00197 BMW-F.22 b)-do-labourchargesonly Each 47
a)S&FGunmetalGate(GMpeet)valveasperIS-778Class -
234 MAT-01848 BMW-F.23 Each 1671
I,Indian makeheavytype-32mmNBSize
235 LAB-00198 BMW-F.24 b)-do-labourchargesonly Each 41
a)S&FGunmetalGate(GMpeet)valveasperIS-778Class -
236 MAT-01849 BMW-F.25 Each 2258
I,Indian makeheavytype-40mmNBSize
237 LAB-00199 BMW-F.26 b)-do-labourchargesonly Each 71
a)S&FGunmetalGate(GMpeet)valveasperIS-778Class -
238 MAT-01850 BMW-F.27 Each 3306
I,Indian makeheavytype-50mmNBSize
239 LAB-00200 BMW-F.28 b)-do-labourchargesonly Each 95
a)S&FGunmetalGate(GMpeet)valveasperIS-778Class -
240 MAT-01851 BMW-F.29 Each 5102
I,Indian makeheavytype-65mmNBSize
241 LAB-00201 BMW-F.30 b)-do-labourchargesonly Each 5160
a)S&FGunmetalGate(GMpeet)valveasperIS-778Class -
242 MAT-01852 BMW-F.31 Each 7557
I,Indian makeheavytype-80mmNBSize
243 LAB-00202 BMW-F.32 b)-do-labourchargesonly Each 141
a) Supplying & fixing Gunmetal (GM) Horizontal Check
244 MAT-01853 BMW-F.33 (Nonreturn) Valve as per IS-778 I-class heavy duty - 15 mm Each 425
NBSize
245 LAB-00203 BMW-F.34 b)-do-labourchargesonly Each 59
a) Supplying & fixing Gunmetal (GM) Horizontal Check
246 MAT-01854 BMW-F.35 (Nonreturn) Valve as per IS-778 I-class heavy duty - 25 mm Each 963
NBSize
247 LAB-00204 BMW-F.36 b)-do-labourchargesonly Each 71
a) Supplying & fixing Gunmetal (GM) Horizontal Check
248 MAT-01855 BMW-F.37 (Nonreturn) Valve as per IS-778 I-class heavy duty - 40 mm Each 1956
NBSize
249 LAB-00205 BMW-F.38 b)-do-labourchargesonly Each 119
a) Supplying & fixing Gunmetal (GM) Horizontal Check
250 MAT-01856 BMW-F.39 (Nonreturn) Valve as per IS-778 I-class heavy duty - 50 mm Each 2670
NBSize
251 LAB-00206 BMW-F.40 b)-do-labourchargesonly Each 119
252 MAT-01857 BMW-F.41 a) Supplying & fixing Gunmetal(GM)HorizontalCheck(Non Each 617

181
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
return)ValveasperIS-778I-classheavyduty-20mmNBSize

253 LAB-00207 BMW-F.42 b)-do-labourchargesonly Each 57


a) Supplying & fixing Gunmetal (GM) Vertical Check
254 MAT-01858 BMW-F.43 (Nonreturn) Valve as per IS-778 I-class heavy duty - 15 mm Each 401
NBSize
255 LAB-00208 BMW-F.44 b)-do-labourchargesonly Each 57
a) Supplying & fixing Gunmetal (GM) Vertical Check
256 MAT-01859 BMW-F.45 (Nonreturn) Valve as per IS-778 I-class heavy duty - 20 mm Each 520
NBSize
257 LAB-00209 BMW-F.46 b)-do-labourchargesonly Each 57
a) Supplying & fixing Gunmetal (GM) Vertical Check
258 MAT-01860 BMW-F.47 (Nonreturn) Valve as per IS-778 I-class heavy duty - 25 mm Each 781
NBSize
259 LAB-00210 BMW-F.48 b)-do-labourchargesonly Each 57
a) Supplying & fixing Gunmetal (GM) Vertical Check
260 MAT-01861 BMW-F.49 (Nonreturn) Valve as per IS-778 I-class heavy duty - 32 mm Each 1073
NBSize
261 LAB-00211 BMW-F.50 b)-do-labourchargesonly Each 57
a) Supplying & fixing Gunmetal (GM) Vertical Check
262 MAT-01862 BMW-F.51 (Nonreturn) Valve as per IS-778 I-class heavy duty - 40 mm Each 1295
NBSize
263 LAB-00212 BMW-F.52 b)-do-labourchargesonly Each 57
a) Supplying & fixing Gunmetal (GM) Vertical Check
264 MAT-01863 BMW-F.53 (Nonreturn) Valve as per IS-778 I-class heavy duty - 50 mm Each 2049
NBSize
265 LAB-00213 BMW-F.54 b)-do-labourchargesonly Each 57
a)S & F Gunmetal (GM) Ball valve with SS Ball and
266 MAT-01864 BMW-F.55 SSSpindle as per IS - Class - I, Indian make heavy type - Each 431
15mmNBSize
267 LAB-00214 BMW-F.56 b)-do-labourchargesonly Each 57
a)S & F Gunmetal (GM) Ball valve with SS Ball and
268 MAT-01865 BMW-F.57 SSSpindle as per IS - Class - I, Indian make heavy type - Each 560
20mmNBSize
269 LAB-00215 BMW-F.58 b)-do-labourchargesonly Each 57
a)S & F Gunmetal (GM) Ball valve with SS Ball and
270 MAT-01866 BMW-F.59 SSSpindle as per IS - Class - I, Indian make heavy type - Each 817
25mmNBSize
271 LAB-00216 BMW-F.60 b)-do-labourchargesonly Each 57
a)S & F Gunmetal (GM) Ball valve with SS Ball and
272 MAT-01867 BMW-F.61 SSSpindle as per IS - Class - I, Indian make heavy type - Each 1477
32mmNBSize
273 LAB-00217 BMW-F.62 b)-do-labourchargesonly Each 57
a)S & F Gunmetal (GM) Ball valve with SS Ball and
274 MAT-01868 BMW-F.63 SSSpindle as per IS - Class - I, Indian make heavy type - Each 2212
40mmNBSize

182
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
275 LAB-00218 BMW-F.64 b)-do-labourchargesonly Each 2238
a)S & F Gunmetal (GM) Ball valve with SS Ball and
276 MAT-01869 BMW-F.65 SSSpindle as per IS - Class - I, Indian make heavy type - Each 3850
50mmNBSize
277 LAB-00219 BMW-F.66 b)-do-labourchargesonly Each 57
a)S&F15mmNominalBoreGIpipeLightGradeproperties &
278 MAT-05237 BMW-F.67 weight as per IS 1239 ISI mark with GI fittingsincluding the 1RM 170
cost of pipe & its fittings & labour chargescomplete

279 LAB-00221 BMW-F.68 b)-do-labourchargesonly 1RM 43


a)S&F20mmNominalBoreGIpipeLightGradeproperties &
280 MAT-05238 BMW-F.69 weight as per IS 1239ISI mark with GI fittingsincluding the 1RM 194
cost of pipe & its fittings & labour chargescomplete

281 LAB-00223 BMW-F.70 b)-do-labourchargesonly 1RM 43


a)S&F25mmNominalBoreGIpipeLightGradeproperties &
282 MAT-05239 BMW-F.71 weight as per IS 1239ISI mark with GI fittingsincluding the 1RM 253
cost of pipe & its fittings & labour chargescomplete

283 LAB-00225 BMW-F.72 b)-do-labourchargesonly 1RM 43


a)S&F32mmNominalBoreGIpipeLightGradeproperties &
284 MAT-05240 BMW-F.73 weight as per IS 1239ISI mark with GI fittingsincluding the 1RM 351
cost of pipe & its fittings & labour chargescomplete

285 LAB-00227 BMW-F.74 b)-do-labourchargesonly 1RM 43


a)S&F40mmNominalBoreGIpipeLightGradeproperties &
286 MAT-05241 BMW-F.75 weight as per IS 1239 ISI mark with GI fittingsincluding the 1RM 394
cost of pipe & its fittings & labour chargescomplete

287 LAB-00229 BMW-F.76 b)-do-labourchargesonly 1RM 47


a)S&F50mmNominalBoreGIpipeLightGradeproperties &
288 MAT-05242 BMW-F.77 weight as per IS 1239 ISI mark with GI fittingsincluding the 1RM 432
cost of pipe & its fittings & labour chargescomplete

289 LAB-00231 BMW-F.78 b)-do-labourchargesonly 1RM 71


a)S&F15mmNominalBoreGIpipeMediumGradeproperties &
290 MAT-05243 BMW-F.79 weight as per IS 1239 ISI mark with GI fittingsincluding the 1RM 188
cost of pipe & its fittings & labourchargescomplete

291 LAB-00233 BMW-F.80 b)-do-labourchargesonly 1RM 43


a)S&F20mmNominalBoreGIpipeMediumGradeproperties &
292 MAT-05244 BMW-F.81 weight as per IS 1239ISI mark with GI fittingsincluding the 1RM 208
cost of pipe & itsfittings & labour chargescomplete

293 LAB-00235 BMW-F.82 b)-do-labourchargesonly 1RM 43


a)S&F25mmNominalBoreGIpipeMediumGradeproperties&w
294 MAT-05245 BMW-F.83 1RM 270
eightasperIS1239ISImarkwithGIfittings

183
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
includingthecostofpipe&itsfittings&labourchargescomplete

295 LAB-00237 BMW-F.84 b)-do-labourchargesonly 1RM 43


a)S&F32mmNominalBoreGIpipeMediumGradeproperties &
296 MAT-05246 BMW-F.85 weight as per IS 1239ISI mark with GI fittingsincluding the 1RM 376
cost of pipe & its fittings & labour chargescomplete

297 LAB-00239 BMW-F.86 b)-do-labourchargesonly 1RM 43


a)S&F40mmNominalBoreGIpipeMediumGradeproperties &
298 MAT-05247 BMW-F.87 weight as per IS 1239 ISI mark with GI fittingsincluding the 1RM 420
cost of pipe & its fittings & labour chargescomplete

299 LAB-00241 BMW-F.88 b)-do-labourchargesonly 1RM 47


a)S&F50mmNominalBoreGIpipeMediumGradeproperties &
300 MAT-05248 BMW-F.89 weight as per IS 1239 ISI mark with GI fittingsincluding the 1RM 457
cost of pipe & its fittings & labour chargescomplete

301 LAB-00243 BMW-F.90 b)-do-labourchargesonly 1RM 71


S&F65mmNominalBoreGIpipeMediumGradeproperties &
weight as per IS 1239 with GI fittings such aselbows tees
302 MAT-01870 BMW-F.91 couplings, nipples, plugs including 1RM
excavationfortrenchesand refilling the 791
trenchescompleteexcept forGI bends union and GI
connectors with checkout and
socketTataorZenithmakeorequivalent.
303 MAT-01871 BMW-F.92 a)S&F12.7mmholderbatclamps Each 13
304 LAB-00244 BMW-F.93 b)-do-labourchargesonly Each 8
305 MAT-01872 BMW-F.94 a)S&F19.05mm holderbatclamps Each 20
306 LAB-00245 BMW-F.95 b)-do-labourchargesonly Each 0
307 MAT-01873 BMW-F.96 a)S&F25.4mmholderbatclamps Each 26
308 LAB-00246 BMW-F.97 b)-do-labourchargesonly Each 8
309 MAT-01874 BMW-F.98 a)S&F38.1mmholderbatclamps Each 29
310 LAB-00247 BMW-F.99 b)-do-labourchargesonly Each 10
BMW- a)S&F12.7x152.0 mmNP showerrose heavy
311 MAT-01875 Each 169
F.100
BMW- b)-do-labourchargesonly
312 LAB-00248 Each 21
F.101
BMW- a)S&F12.7x137.0 mmNP showerrose heavy
313 MAT-01876 Each 162
F.102
BMW- b)-do-labourchargesonly
314 LAB-00249 Each 23
F.103
BMW- a)S&F12.7x101.6 mmNP showerrose heavy
315 MAT-01877 Each 154
F.104
BMW- b)-do-labourchargesonly
316 LAB-00250 Each 23
F.105
317 MAT-01878 BMW- a)S &F12.7x 88.9 CPfancy shower Each 272

184
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
F.106
BMW- b)-do-labourchargesonly
318 LAB-00251 Each 23
F.107
BMW- a)Supplying&fixing12.7mmGIdrainpipewithplugfortanks(Mud
319 MAT-01879 Each 45
F.108 valve)includingmakingahole
BMW- b)-do-labourchargesonly
320 LAB-00252 Each 23
F.109
BMW- a) Supplying& fixing19.05 mm GIdrain pipewith plug
321 MAT-01880 Each 64
F.110 fortanks(Mudvalve)includingmakinga hole
BMW- b)-do-labourchargesonly
322 LAB-00253 Each 22
F.111
BMW- a)Supplying&fixing25.4mmGIdrainpipewithplugfortanks(Mud
323 MAT-01881 Each 75
F.112 valve)includingmakingahole
BMW- b)-do-labourchargesonly
324 LAB-00254 Each 25
F.113
a) Taking branch water connection from the existing
325 MAT-01882 BMW- Each
25.4mm GIpipe including cutting threading, etc, complete 144
F.114
withfitting
BMW- b)-do-labourchargesonly
326 LAB-00255 Each 25
F.115
a) Taking branch water connection from the existing
327 MAT-01883 BMW- Each
19.05mm GIpipe including cutting threading, etc, complete 83
F.116
withfitting,
BMW- b)-do-labourchargesonly
328 LAB-00256 Each 38
F.117
a) Taking branch water connection from the existing
329 MAT-01884 BMW- Each
12.7mm GIpipe including cutting threading, etc, complete 63
F.118
withfitting,
BMW- b)-do-labourchargesonly
330 LAB-00257 Each 33
F.119
BMW- Supplying&fixingleatherwashersfor12.7mmbibtapandstopco
331 MAT-01885 Each 1
F.120 ck
BMW- Supplying&fixingleatherwashersfor19.05mmbibtapandstopc
332 MAT-01886 Each 3
F.121 ock
BMW- Supplying&Fixing12.7mmfibrewashers
333 MAT-01887 Each 3
F.122
BMW- Supplying&Fixing 19.05mmfibrewashers
334 MAT-01888 Each 3
F.123
PVCPIPES&FITTINGS(Materialsshallbeprocuredfromthelist
G
ofapprovedBrands/ Manufacturers/ Suppliers)
a)Providing&PlacingonTerrace(atallfloorlevels)polyethylene
water storage tank with Double layer
335 MAT-01889 BMW-G.01 approvedbrand&manufacturewithcoverandsuitablelockingarr 1Lit
5
angement & making necessary holes for inlet & outletsand
over flow pipes but without fittings & base support fortanks

336 LAB-00258 BMW-G.02 b)-do-labourchargesonly 1Lit 1

185
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
337 MAT-01890 BMW-G.03 SupplyofPlasticstoragetanklidwithhinges Each 67
338 MAT-01891 BMW-G.04 Supply &Fixing76.2 mmdiaPVCelbowIstquality Each 43
Supply&fixing31.75mmdiaPVCflexiblewastepipeof
339 MAT-01892 BMW-G.05 Each 23
914.4mmlengthof Istquality
340 MAT-01893 BMW-G.06 Supply &Fixing38.1mm diaPVCsolidwaste pipeoutlet Each 81
341 MAT-01894 BMW-G.07 Supply&fixingFancyPVC shelfincludingallfittings Each 192
Supply&fixingofPVClowlevelsystemwithinternalcomponents
342 MAT-01895 BMW-G.08 Each 1314
&shortbend:10LitrescapacitySingleFlush
Supply&fixingofPVClowlevelsystemwithinternalcomponents
343 MAT-01896 BMW-G.09 Each 1543
&short bend:10litrescapacityDualFlush
Supply&fixingofPVClowlevelsystemwithinternalcomponents
344 MAT-01897 BMW-G.10 Each 743
&short bend:8LitrescapacitysingleFlush
345 MAT-01898 BMW-G.11 75mmdia 3MSingle SocketPVC/SWRpipe - 4Kg/sq.cm Each 225
346 MAT-01899 BMW-G.12 90mmdia 3Msingle SocketPVC/SWRpipe -4Kg/sq.cm Each 357
347 MAT-01900 BMW-G.13 110mmdia3MSingleSocket PVC/SWR pipe-4Kg/sq.cm Each 426
348 MAT-01901 BMW-G.14 75mmdia3MDoubleSocketPVC/SWR pipe -4Kg/sq.cm Each 254
349 MAT-01902 BMW-G.15 90mmdia3MDoubleSocketPVC/SWR pipe -4Kg/sq.cm Each 405
350 MAT-01903 BMW-G.16 110mm dia3MDoubleSocketPVC/SWRpipe -4Kg/sq.cm Each 495
75mmdia1828.8mm(6'-0")SingleSocketPVC/SWRpipe
351 MAT-01904 BMW-G.17 Each 158
-4Kg/sq.cm
90mmdia1828.8mm(6'-0")SingleSocketPVC/SWRpipe
352 MAT-01905 BMW-G.18 Each 243
-4Kg/sq.cm
110mmdia1828.8mm(6'-0")SingleSocketPVC/SWRpipe-
353 MAT-01906 BMW-G.19 Each 303
4Kg/sq.cm
75mmdia1828.8mm(6'-0")DoubleSocketPVC/SWRpipe-
354 MAT-01907 BMW-G.20 Each 168
4Kg/sq.cm
90mmdia1828.8mm(6'-0")DoubleSocketPVC/SWRpipe-
355 MAT-01908 BMW-G.21 Each 259
4Kg/sq.cm
110mmdia1828.8mm(6'-0")DoubleSocketPVC/SWRpipe-
356 MAT-01909 BMW-G.22 Each 313
4Kg/sq.cm
75mmdia1219.mm(4'-0")DoubleSocketPVC/SWRpipe
357 MAT-01910 BMW-G.23 Each 116
-4Kg/sq.cm
90mmdia1219.mm(4'-0")DoubleSocketPVC/SWRpipe
358 MAT-01911 BMW-G.24 Each 178
-4Kg/sq.cm
110mmdia1219.mm(4'-0")DoubleSocketPVC/SWRpipe-
359 MAT-01912 BMW-G.25 Each 214
4Kg/sq.cm
75mmdia 914.4mm(3'-0") DoubleSocketPVC/SWRpipe-
360 MAT-01913 BMW-G.26 Each 98
4Kg/sq.cm
90mmdia914.4mm(3'-0")DoubleSocketPVC/SWRpipe-
361 MAT-01914 BMW-G.27 Each 144
4Kg/sq.cm
110mmdia914.4mm(3'-0")DoubleSocketPVC/SWRpipe
362 MAT-01915 BMW-G.28 Each 185
-4Kg/sq.cm
75mmdia609.6mm(2'-0")DoubleSocketPVC/SWRpipe-
363 MAT-01916 BMW-G.29 Each 59
4Kg/sq.cm

186
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
90mmdia609.6mm(2'-0")DoubleSocketPVC/SWRpipe-
364 MAT-01917 BMW-G.30 Each 99
4Kg/sq.cm
110mmdia609.6mm(2'-0")DoubleSocketPVC/SWRpipe
365 MAT-01918 BMW-G.31 Each 124
-4Kg/sq.cm
160MMdia3MDoubleSocketPVC/SWRpipe-4Kg/sq.cm
366 MAT-01919 BMW-G.32 Each 1015

367 MAT-01920 BMW-G.33 75mmdia 3MSingle SocketPVC/SWRpipe - 6Kg/sq.cm Each 381


368 MAT-01921 BMW-G.34 90mmdia 3Msingle SocketPVC/SWRpipe -6Kg/sq.cm Each 613
369 MAT-01922 BMW-G.35 110mmdia3MSingleSocketPVC/SWR pipe -6Kg/sq.cm Each 729
370 MAT-01923 BMW-G.36 75mmdia3MDoubleSocketPVC/SWR pipe -6Kg/sq.cm Each 416
371 MAT-01924 BMW-G.37 90mmdia3MDoubleSocketPVC/SWR pipe -6Kg/sq.cm Each 660
372 MAT-01925 BMW-G.38 110mm dia3MDoubleSocketPVC/SWRpipe -6Kg/sq.cm Each 805
75mmdia1828.8mm(6'-0")SingleSocketPVC/SWRpipe
373 MAT-01926 BMW-G.39 Each 250
-6Kg/sq.cm
90mmdia1828.8mm(6'-0")SingleSocketPVC/SWRpipe
374 MAT-01927 BMW-G.40 Each 388
-6Kg/sq.cm
110mmdia1828.8mm(6'-0")SingleSocketPVC/SWRpipe-
375 MAT-01928 BMW-G.41 Each 462
6Kg/sq.cm
75mmdia1828.8mm(6'-0")DoubleSocketPVC/SWRpipe-
376 MAT-01929 BMW-G.42 Each 267
6Kg/sq.cm
90mmdia1828.8mm(6'-0")DoubleSocketPVC/SWRpipe-
377 MAT-01930 BMW-G.43 Each 405
6Kg/sq.cm
110mmdia1828.8mm(6'-0")DoubleSocketPVC/SWRpipe-
378 MAT-01931 BMW-G.44 Each 499
6Kg/sq.cm
75mmdia1219.mm(4'-0")DoubleSocketPVC/SWRpipe
379 MAT-01932 BMW-G.45 Each 181
-6Kg/sq.cm
90mmdia1219.mm(4'-0")DoubleSocketPVC/SWRpipe
380 MAT-01933 BMW-G.46 Each 280
-6Kg/sq.cm
110mmdia1219.mm(4'-0")DoubleSocketPVC/SWRpipe-
381 MAT-01934 BMW-G.47 Each 341
6Kg/sq.cm
75mmdia914.4mm(3'-0")DoubleSocketPVC/SWRpipe-
382 MAT-01935 BMW-G.48 Each 156
6Kg/sq.cm
90mmdia914.4mm(3'-0")DoubleSocketPVC/SWRpipe-
383 MAT-01936 BMW-G.49 Each 229
6Kg/sq.cm
110mmdia914.4mm(3'-0")DoubleSocketPVC/SWRpipe
384 MAT-01937 BMW-G.50 Each 277
-6Kg/sq.cm
75mmdia609.6mm(2'-0")DoubleSocketPVC/SWRpipe-
385 MAT-01938 BMW-G.51 Each 101
6Kg/sq.cm
90mmdia609.6mm(2'-0")DoubleSocketPVC/SWRpipe-
386 MAT-01939 BMW-G.52 Each 157
6Kg/sq.cm
110mmdia609.6mm(2'-0")DoubleSocketPVC/SWRpipe
387 MAT-01940 BMW-G.53 Each 200
-6Kg/sq.cm
160mmdia3MDoubleSocketPVC/SWRpipe-6Kg/sq.cm
388 MAT-01941 BMW-G.54 Each 1660

187
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
75mmdia-PlainBend87.5Degree-UPVC/SWRPipefittings
389 MAT-01942 BMW-G.55 Each 44

90mmdia-PlainBend87.5Degree-UPVC/SWRPipefittings
390 MAT-01943 BMW-G.56 Each 61

110mmdia-PlainBend87.5Degree-UPVC/SWRPipefittings
391 MAT-01944 BMW-G.57 Each 73

75mmdia-DoorBend87.5Degree-UPVC/SWRPipefittings
392 MAT-01945 BMW-G.58 Each 59

90mmdia-DoorBend87.5Degree-UPVC/SWRPipefittings
393 MAT-01946 BMW-G.59 Each 83

110mmdia-DoorBend87.5Degree-UPVC/SWRPipefittings
394 MAT-01947 BMW-G.60 Each 95

395 MAT-01948 BMW-G.61 75mmdia-45Degree Bend-UPVC/SWR Pipefittings Each 34


396 MAT-01949 BMW-G.62 90mmdia-45Degree Bend-UPVC/SWR Pipefittings Each 48
397 MAT-01950 BMW-G.63 110mmdia -45 DegreeBend-UPVC/SWR Pipefittings Each 61
398 MAT-01951 BMW-G.64 75mmdia-CleaningPipe -UPVC/SWR Pipefittings Each 59
399 MAT-01952 BMW-G.65 90mmdia-CleaningPipe -UPVC/SWR Pipefittings Each 86
400 MAT-01953 BMW-G.66 110mmdia -Cleaning Pipe-UPVC/SWRPipe fittings Each 104
401 MAT-01954 BMW-G.67 75mmdia-SingleTee-UPVC/SWRPipefittings Each 52
402 MAT-01955 BMW-G.68 90mmdia-SingleTee-UPVC/SWRPipefittings Each 78
403 MAT-01956 BMW-G.69 110mmdia -SingleTee- UPVC/SWR Pipefittings Each 95
404 MAT-01957 BMW-G.70 75mmdia-SingleTeewithDoor -UPVC/SWR Pipe fittings Each 64
405 MAT-01958 BMW-G.71 90mmdia-SingleTeewithDoor -UPVC/SWR Pipe fittings Each 95
110mmdia-SingleTeewithDoor-UPVC/SWRPipefittings
406 MAT-01959 BMW-G.72 Each 114

407 MAT-01960 BMW-G.73 75mmdia-DoubleTee-UPVC/SWR Pipefittings Each 100


408 MAT-01961 BMW-G.74 90mmdia-DoubleTee- UPVC/SWRPipefittings Each 161
409 MAT-01962 BMW-G.75 110mmdia -DoubleTee- UPVC/SWR Pipefittings Each 190
75mmdia-DoubleTeewithDoor-UPVC/SWRPipefittings
410 MAT-01963 BMW-G.76 Each 133

90mmdia-DoubleTeewithDoor-UPVC/SWRPipefittings
411 MAT-01964 BMW-G.77 Each 252

110mmdia-DoubleTeewithDoor-UPVC/SWRPipefittings
412 MAT-01965 BMW-G.78 Each 246

413 MAT-01966 BMW-G.79 75mmdia-Single'Y'-UPVC/SWR Pipe fittings Each 66


414 MAT-01967 BMW-G.80 90mmdia- Single'Y' -UPVC/SWRPipefittings Each 104
415 MAT-01968 BMW-G.81 110mmdia -Single'Y'-UPVC/SWR Pipefittings Each 120
416 MAT-01969 BMW-G.82 75mmdia-Single'Y'withDoor -UPVC/SWRPipefittings Each 83
417 MAT-01970 BMW-G.83 90mmdia-Single'Y'withDoor -UPVC/SWRPipefittings Each 131
418 MAT-01971 BMW-G.84 110mmdia -Single'Y'withDoor-UPVC/SWR Pipefittings Each 151
419 MAT-01972 BMW-G.85 75mmdia-Double'Y'-UPVC/SWRPipefittings Each 89

188
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
420 MAT-01973 BMW-G.86 90mmdia-Double'Y'-UPVC/SWRPipefittings Each 139
421 MAT-01974 BMW-G.87 110mmdia -Double'Y'-UPVC/SWR Pipefittings Each 158
422 MAT-01975 BMW-G.88 75mmdia-Double'Y'with Door-UPVC/SWRPipefittings Each 116
423 MAT-01976 BMW-G.89 90mmdia-Double'Y'with Door -UPVC/SWRPipefittings Each 181
110mmdia-Double'Y'withDoor-UPVC/SWRPipefittings
424 MAT-01977 BMW-G.90 Each 204

425 MAT-01978 BMW-G.91 75mmdia-Coupler-UPVC/SWR Pipe fittings Each 31


426 MAT-01979 BMW-G.92 90mmdia-Coupler-UPVC/SWR Pipefittings Each 45
427 MAT-01980 BMW-G.93 110mmdia -Coupler-UPVC/SWR Pipefittings Each 50
428 MAT-01981 BMW-G.94 90x75mm dia-Reducer - UPVC/SWRPipefittings Each 52
429 MAT-01982 BMW-G.95 110x75mmdia-Reducer-UPVC/SWR Pipefittings Each 50
430 MAT-01983 BMW-G.96 90x110mmdia-Reducer-UPVC/SWR Pipefittings Each 70
431 MAT-01984 BMW-G.97 63mmdia- VentCowl-UPVC/SWR Pipefittings Each 8
432 MAT-01985 BMW-G.98 75mmdia- VentCowl-UPVC/SWR Pipefittings Each 12
433 MAT-01986 BMW-G.99 90mmdia- VentCowl-UPVC/SWR Pipefittings Each 15
BMW- 110mmdia -VentCowl- UPVC/SWR Pipefittings
434 MAT-01987 Each 17
G.100
BMW- 40mmdia-PipeClip-UPVC/SWRPipefittings-PipeClip
435 MAT-01988 Each 9
G.101 -UPVC/SWR Pipefittings
BMW- 50mmdia- PipeClip-UPVC/SWRPipe fittings
436 MAT-01989 Each 12
G.102
BMW- 63mmdia- PipeClip-UPVC/SWRPipe fittings
437 MAT-01990 Each 12
G.103
BMW- 75mmdia- PipeClip-UPVC/SWRPipe fittings
438 MAT-01991 Each 14
G.104
BMW- 90mmdia- PipeClip-UPVC/SWRPipe fittings
439 MAT-01992 Each 15
G.105
BMW- 110mm-PipeClip-UPVC/SWRPipefittings
440 MAT-01993 Each 16
G.106
BMW- 160mmdia -Pipe Clip-UPVC/SWR Pipefittings
441 MAT-01994 Each 31
G.107
BMW- P'Trap(SmallwithoutAirvent)110mm-UPVC/SWRPipefittings
442 MAT-01995 Each 165
G.108
BMW- P'Trap(SmallwithAirvent)110mm-UPVC/SWRPipefittings
443 MAT-01996 Each 183
G.109
BMW- P'Trap(BigwithAirvent)110mm-UPVC/SWRPipefittings
444 MAT-01997 Each 209
G.110
BMW- P'Trap(BigwithoutAirvent)110mm-UPVC/SWRPipefittings
445 MAT-01998 Each 192
G.111
BMW- FloorTrap(BellMouth)110mm-UPVC/SWRPipe fittings
446 MAT-01999 Each 200
G.112
BMW- BellMouthTrap 7"(177.8mm)-UPVC/SWR Pipefittings
447 MAT-02000 Each 290
G.113

189
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
BMW- 4"(101.6mm)NahanyTrap(WithoutJaliwithinlet)UPVC/SWRPip
448 MAT-02001 Each 86
G.114 efittings
BMW- 3"(76.2mm)NahanyTrap(withoutJaliwithoutinlet)UPVC/SWRPi
449 MAT-02002 Each 77
G.115 pefittings
BMW- 4"(101.6mm)NahanyTrap(withoutinletwithoutJali)UPVC/SWRP
450 MAT-02003 Each 86
G.116 ipefittings
BMW- MiniTrap-UPVC/SWRPipefittings
451 MAT-02004 Each 47
G.117
BMW- 3"(76.2mm)NahanyTrapwithJali-UPVC/SWRPipefittings
452 MAT-02005 Each 89
G.118
BMW- 4"(101.6mm)multifloortrapwithJali-UPVC/SWRPipefittings
453 MAT-02006 Each 127
G.119
BMW- 4"(101.6)multifloortrapwithoutJalli-UPVC/SWRPipefittings
454 MAT-02007 Each 99
G.120
BMW- RoundJali-UPVC/SWR Pipefittings
455 MAT-02008 Each 21
G.121
BMW- Squaretile&Jalli-UPVC/SWR Pipe fittings
456 MAT-02009 Each 34
G.122
BMW- Pipeconnector(withLIPring) -UPVC/SWRPipefittings
457 MAT-02010 Each 127
G.123
BMW- Pipeconnector(with outLIPring)-UPVC/SWRPipefittings
458 MAT-02011 Each 103
G.124
BMW- 4"(101.6mm)FloorTrap- UPVC/SWR Pipe fittings
459 MAT-02012 Each 122
G.125
BMW- 5"(127.mm)floorTrap-UPVC/SWR Pipefittings
460 MAT-02013 Each 129
G.126
BMW- 75mmdia-Doorcap-UPVC/SWR Pipe fittings
461 MAT-02014 Each 32
G.127
BMW- 90mmdia-Doorcap-UPVC/SWR Pipe fittings
462 MAT-02015 Each 56
G.128
BMW- 110mmdia-Doorcap-UPVC/SWR Pipefittings
463 MAT-02016 Each 47
G.129
BMW- 75mmdia- Socketplug-UPVC/SWR Pipefittings
464 MAT-02017 Each 31
G.130
BMW- 90mmdia- Socketplug-UPVC/SWR Pipefittings
465 MAT-02018 Each 54
G.131
BMW- 110mmdia -Socketplug- UPVC/SWR Pipefittings
466 MAT-02019 Each 56
G.132
BMW- 75mmdia-RubberringforSocket-UPVC/SWRPipefittings
467 MAT-02020 Each 7
G.133
BMW- 90mmdia-RubberringforSocket-UPVC/SWRPipefittings
468 MAT-02021 Each 8
G.134
BMW- 110mmdia-RubberringforSocket-UPVC/SWRPipefittings
469 MAT-02022 Each 9
G.135
BMW- 75mmdia-DoorSocket-UPVC/SWR Pipefittings
470 MAT-02023 Each 8
G.136

190
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
BMW- 90mmdia-DoorSocket-UPVC/SWR Pipefittings
471 MAT-02024 Each 9
G.137
BMW- 110mmdia -Door Socket- UPVC/SWR Pipefittings
472 MAT-02025 Each 12
G.138
BMW- LIPring110mm -UPVC/SWR Pipefittings
473 MAT-02026 Each 60
G.139
BMW- RubberLubricant- 100Grams
474 MAT-02027 Each 23
G.140
BMW- RubberLubricant-250Grams
475 MAT-02028 Each 45
G.141
BMW- RubberLubricant- 500Grams
476 MAT-02029 Each 81
G.142
BMW- RubberLubricant- 1000Grams
477 MAT-02030 Each 192
G.143
BMW- P'TrapwithlipUPVC/SWR Pipefittings
478 MAT-02031 Each 262
G.144
BMW- 50ml-SolventCement
479 MAT-02032 Each 14
G.145
BMW- 100ml- SolventCement
480 MAT-02033 Each 22
G.146
BMW- 250ml- SolventCement
481 MAT-02034 Each 52
G.147
BMW- 500ml- SolventCement
482 MAT-02035 Each 102
G.148
BMW- 1000ml-SolventCement
483 MAT-02036 Each 200
G.149
BMW- 110mmx90mm-InternalReducer-UPVC/SWRPipefittings
484 MAT-02037 Each 79
G.150
BMW- 160mmx110mm-InternalReducer-UPVC/SWRPipefittings
485 MAT-02038 Each 198
G.151
Labourchargesforlaying,fixingandcommissioningthePVC
BMW- pipes including couplers/ bends/ tees etc any
486 LAB-00259 diameterincludingfixingnecessaryfittingslikebends,plugs,cou 1RM 74
G.152
plers, junctions, tees, etc with solvent jointing as
perstandard practice
CENTRIFUGALCASTIRONPIPES&FITTNGSASPERIS:398
H
9- 1984
487 MAT-02039 BMW-H.01 75mmdiaCI(spun)soils Waste &Ventilating pipe(3 M) Each 1321
488 MAT-02040 BMW-H.02 100mmdiaCI(spun)soils Waste& Ventilatingpipe(3M) Each 1759
489 MAT-02041 BMW-H.03 150mmdiaCI(spun)soils Waste& Ventilatingpipe(3M) Each 3223
75mmdiaCI(spun)soilsWaste&Ventilatingpipe(3M)Doubleso
490 MAT-02042 BMW-H.04 Each 1466
cket
100mmdiaCI(spun)soilsWaste&Ventilatingpipe(3M)Doubles
491 MAT-02043 BMW-H.05 Each 1978
ocket
492 MAT-02044 BMW-H.06 75mmdia 9'-0"(2743.2 mm)CI(Spun)pipes Each 1188

191
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
493 MAT-02045 BMW-H.07 100mmdia9'-0"(2743.2mm)CI(Spun)pipes Each 1587
494 MAT-02046 BMW-H.08 75mmdia8'-0"(2438.4 mm)CI(Spun)pipes Each 1063
495 MAT-02047 BMW-H.09 100mmdia8'-0"(2438.4mm)CI(Spun)pipes Each 1412
496 MAT-02048 BMW-H.10 75mmdia 6'-0"(1828.8 mm)CI(Spun)pipes Each 864
497 MAT-02049 BMW-H.11 100mmdia6'-0"(1828.8mm)CI(Spun)pipes Each 1127
75mmdia6'-0"(1828.8mm)DoubleSocketCI(Spun)pipes
498 MAT-02050 BMW-H.12 Each 909

100mmdia6'-0"(1828.8mm)DoubleSocketCI(Spun)pipes
499 MAT-02051 BMW-H.13 Each 1127

75mmdiaCutpipes(pieces)1foot(304.8mm)CI(Spun)fittings
500 MAT-02052 BMW-H.14 Each 315

100mmdiaCutpipes(pieces)1foot(304.8mm)CI(Spun)fittings
501 MAT-02053 BMW-H.15 Each 362

75mmdiaCutpipes(pieces)1'.6"(457.2mm)CI(Spun)fittings
502 MAT-02054 BMW-H.16 Each 451

100mmdiaCutpipes(pieces)1'.6"(457.2mm)CI(Spun)fittings
503 MAT-02055 BMW-H.17 Each 519

150mmdiaCutpipes(pieces)1'.6"(457.2mm)CI(Spun)fittings
504 MAT-02056 BMW-H.18 Each 990

75mmdiaCutpipes(pieces)2feet(609.6mm)CI(Spun)fittings
505 MAT-02057 BMW-H.19 Each 623

100mmdiaCutpipes(pieces)2feet(609.6mm)CI(Spun)fittings
506 MAT-02058 BMW-H.20 Each 687

150mmdiaCutpipes(pieces)2feet(609.6mm)CI(Spun)fittings
507 MAT-02059 BMW-H.21 Each 1241

75mmdiaCutpipes(pieces)3feet(914.4mm)CI(Spun)fittings
508 MAT-02060 BMW-H.22 Each 955

100mmdiaCutpipes(pieces)3feet(914.4mm)CI(Spun)fittings
509 MAT-02061 BMW-H.23 Each 1289

75mm diaCutpipes (pieces) 4 feet(1219.2mm) CI


510 MAT-02062 BMW-H.24 Each 1050
(Spun)fittings
100mmdiaCutpipes(pieces)4feet(1219.2mm)CI(Spun)fittings
511 MAT-02063 BMW-H.25 Each 1571

512 MAT-02064 BMW-H.26 75mmdia PlainBend-CI(Spun)fittings Each 324


513 MAT-02065 BMW-H.27 100mmdiaPlainBend-CI (Spun)fittings Each 382
514 MAT-02066 BMW-H.28 150mmdiaPlainBend-CI (Spun)fittings Each 909
515 MAT-02067 BMW-H.29 75mmdiaDoorBend-CI(Spun)fittings Each 336
516 MAT-02068 BMW-H.30 100mmdiaDoor Bend-CI (Spun)fittings Each 435
517 MAT-02069 BMW-H.31 150mmdiaDoor Bend-CI (Spun)fittings Each 995
518 MAT-02070 BMW-H.32 75mmdia PlainBend 45 Degrees-CI(Spun)fittings Each 324
519 MAT-02071 BMW-H.33 100mmdiaPlainBend45Degrees -CI (Spun)fittings Each 382
520 MAT-02072 BMW-H.34 150mmdiaPlainBend45Degrees -CI (Spun)fittings Each 909
521 MAT-02073 BMW-H.35 75mmdiaDoorBend45Degrees-CI(Spun)fittings Each 336

192
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
522 MAT-02074 BMW-H.36 100mmdiaDoor Bend45Degrees-CI (Spun)fittings Each 435
523 MAT-02075 BMW-H.37 150mmdiaDoor Bend45Degrees-CI (Spun)fittings Each 995
HornBendPlain101.6x50.8mm(4"x2")100mmdia-
524 MAT-02076 BMW-H.38 Each 660
CI(Spun)fittings
HornBenddoor101.6x50.8mm(4"x2")100mmdia-
525 MAT-02077 BMW-H.39 Each 771
CI(Spun)fittings
526 MAT-02078 BMW-H.40 75mmdiaHeelRest Bend-CI(Spun)fittings Each 345
527 MAT-02079 BMW-H.41 100mm dia HeelRestBend -CI(Spun)fittings Each 441
528 MAT-02080 BMW-H.42 150mm dia HeelRestBend -CI(Spun)fittings Each 938
529 MAT-02081 BMW-H.43 75mmdiaSingle BranchPlain"T"-CI(Spun)fittings Each 435
530 MAT-02082 BMW-H.44 100mmdiaSingleBranch Plain"T"-CI(Spun)fittings Each 587
531 MAT-02083 BMW-H.45 150mmdiaSingleBranch Plain"T"-CI(Spun)fittings Each 1211
532 MAT-02084 BMW-H.46 75mmdiaSingle BranchDoor"T"-CI(Spun)fittings Each 513
533 MAT-02085 BMW-H.47 100mmdiaSingleBranchDoor"T"-CI(Spun)fittings Each 680
534 MAT-02086 BMW-H.48 150mmdiaSingleBranchDoor"T"-CI(Spun)fittings Each 1278
535 MAT-02087 BMW-H.49 75mmdiaSingleBranchplain"Y"-CI(Spun)fittings Each 513
536 MAT-02088 BMW-H.50 100mmdiaSingleBranch plain"Y"-CI (Spun)fittings Each 680
537 MAT-02089 BMW-H.51 150mmdiaSingleBranch plain"Y"-CI (Spun)fittings Each 1501
538 MAT-02090 BMW-H.52 75mmdia SingleBranchDoor"Y"-CI(Spun)fittings Each 562
539 MAT-02091 BMW-H.53 100mmdiaSingleBranchDoor"Y"-CI(Spun) fittings Each 751
540 MAT-02092 BMW-H.54 150mmdiaSingleBranchDoor"Y"-CI(Spun) fittings Each 1616
541 MAT-02093 BMW-H.55 75mmdiaDouble BranchPlain"T"-CI(Spun) fittings Each 594
542 MAT-02094 BMW-H.56 100mmdiaDoubleBranch Plain"T"-CI(Spun)fittings Each 800
543 MAT-02095 BMW-H.57 75mmdiaDouble Branch Door"T"-CI(Spun)fittings Each 662
544 MAT-02096 BMW-H.58 100mmdiaDoubleBranch Door"T"-CI(Spun)fittings Each 834
545 MAT-02097 BMW-H.59 75mmdiaDouble BranchPlain"Y"-CI(Spun)fittings Each 662
546 MAT-02098 BMW-H.60 100mmdiaDoubleBranchPlain "Y"-CI(Spun)fittings Each 834
547 MAT-02099 BMW-H.61 75mmdiaDoubleBranch Door"Y"-CI(Spun)fittings Each 698
548 MAT-02100 BMW-H.62 100mmdia DoubleBranchDoor"Y"-CI(Spun)fittings Each 905
549 MAT-02101 BMW-H.63 75mmdia ShoeBend-CI (Spun)fittings Each 410
550 MAT-02102 BMW-H.64 100mmdia ShoeBend-CI(Spun)fittings Each 479
551 MAT-02103 BMW-H.65 150mmdia ShoeBend-CI(Spun)fittings Each 972
552 MAT-02104 BMW-H.66 75mmdiaCollar-CI(Spun)fittings Each 280
553 MAT-02105 BMW-H.67 100mmdiaCollar-CI(Spun)fittings Each 340
554 MAT-02106 BMW-H.68 150mmdiaCollar-CI(Spun)fittings Each 698
555 MAT-02107 BMW-H.69 75mmdiaCowl -CI(Spun)fittings Each 248
556 MAT-02108 BMW-H.70 100mmdia Cowl-CI(Spun)fittings Each 280
557 MAT-02109 BMW-H.71 150mmdia Cowl-CI(Spun)fittings Each 628

193
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
75mmdiaOffset3"(76.2mm)projection-CI(Spun)fittings
558 MAT-02110 BMW-H.72 Each 359

100mmdiaOffset3"(76.2mm)projection-CI(Spun)fittings
559 MAT-02111 BMW-H.73 Each 435

150mmdiaOffset3"(76.2mm)projection-CI(Spun)fittings
560 MAT-02112 BMW-H.74 Each 878

75mmdiaOffset6"(152.4mm)projection-CI(Spun)fittings
561 MAT-02113 BMW-H.75 Each 392

100mmdiaOffset6"(152.4mm)projection-CI(Spun)fittings
562 MAT-02114 BMW-H.76 Each 513

150mmdiaOffset6"(152.4mm)projection-CI(Spun)fittings
563 MAT-02115 BMW-H.77 Each 1022

564 MAT-02116 BMW-H.78 75mmdiaLong DoorBend-CI(Spun)fittings Each 824


565 MAT-02117 BMW-H.79 100mmdiaLongDoorBend-CI(Spun)fittings Each 886
566 MAT-02118 BMW-H.80 75mmdia HandHole pipe(Inspectionpipe) Each 473
567 MAT-02119 BMW-H.81 100mmdiaHandHolepipe(Inspectionpipe) Each 645
568 MAT-02120 BMW-H.82 150mmdiaHandHole pipe(Inspectionpipe) Each 858
569 MAT-02121 BMW-H.83 75mmdia PTraps -CI(Spun)fittings Each 513
570 MAT-02122 BMW-H.84 100mm diaPTraps-CI(Spun)fittings Each 703
4"x3"(101.6mmx76.2mm)P.Traps100mmdia-CI(Spun)fittings
571 MAT-02123 BMW-H.85 Each 806

4"x3"(101.6mmx76.2mm)VentTraps100mmdia-
572 MAT-02124 BMW-H.86 Each 806
CI(Spun)fittings
4"x3"(101.6mmx76.2mm)Reducer75mmdia-CI(Spun)fittings
573 MAT-02125 BMW-H.87 Each 500

6"x4"(152.4mmx101.6mm)Reducer75mmdia-
574 MAT-02126 BMW-H.88 Each 685
CI(Spun)fittings
3"x2"(76.2 mm x 50.8 mm)plain T75 mmdia- CI(Spun)fittings
575 MAT-02127 BMW-H.89 Each 427

3" x 2" ( 76.2 mm x 50.8 mm ) Door T 75 mm dia - CI


576 MAT-02128 BMW-H.90 Each 668
(Spun)fittings
3"x2"(76.2mmx50.8mm)PlainY75mmdia-CI(Spun)fittings
577 MAT-02129 BMW-H.91 Each 668

3"x2"(76.2mmx50.8mm)DoorY75mmdia-CI(Spun)fittings
578 MAT-02130 BMW-H.92 Each 668

4"x3"(101.6mmx76.2mm )Plain T75mm dia-CI (Spun)fittings


579 MAT-02131 BMW-H.93 Each 668

4"x3"(101.6mmx76.2mm)DoorT75mmdia-CI(Spun)fittings
580 MAT-02132 BMW-H.94 Each 707

4" x3"(101.6 mm x76.2mm )PlainY75 mmdia-CI


581 MAT-02133 BMW-H.95 Each 707
(Spun)fittings
4"x3"(101.6mmx76.2mm)DoorY75mmdia-CI(Spun)fittings
582 MAT-02134 BMW-H.96 Each 755

583 MAT-02135 BMW-H.97 6"x4"(152.4mmx101.6mm)PlainT75mmdia-CI Each 988

194
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
(Spun)fittings
6"x4"(152.4mmx101.6mm)DoorT75mmdia-CI(Spun)fittings
584 MAT-02136 BMW-H.98 Each 1070

6"x4"(152.4mmx101.6mm)PlainY75mmdia-CI(Spun)fittings
585 MAT-02137 BMW-H.99 Each 1133

BMW- 6"x4"(152.4mmx101.6mm)DoorY75mmdia-CI(Spun)fittings
586 MAT-02138 Each 1384
H.100
BMW- 75 mm diaPlain " T" 27 " (685.8 mm ) Special Types of
587 MAT-02139 Each 1434
H.101 LongFittings
BMW- 100mmdia-Plain"T"27"(685.8mm)SpecialTypesofLong
588 MAT-02140 Each 2014
H.102 CI(Spun)fittings
BMW- 75mmdiaDoor"T"27"(685.8mm)SpecialTypesofLongCI(Spun
589 MAT-02141 Each 1602
H.103 ) fittings
BMW- 100mmdiaDoor"T"27"(685.8mm)SpecialTypesofLongCI(Spu
590 MAT-02142 Each 2213
H.104 n) fittings
BMW- 75mmdiaPlain"Y"27"(685.8mm)SpecialTypesofLongCI(Spu
591 MAT-02143 Each 1602
H.105 n) fittings
BMW- 100mmdiaPlain"Y"27"(685.8mm)SpecialTypesofLongCI(Sp
592 MAT-02144 Each 2213
H.106 un) fittings
BMW- 75mmdiaDoor"Y"27"(685.8mm)SpecialTypesofLongCI(Spun
593 MAT-02145 Each 1786
H.107 ) fittings
BMW- 100mmdiaDoor"Y"27"(685.8mm)SpecialTypesofLongCI(Spu
594 MAT-02146 Each 2430
H.108 n) fittings
I MISCELLANEOUSITEMS
595 MAT-02147 BMW-I.01 a)Supplying &Fixingsolderjointsup to50.8 mm dia Each 59
596 LAB-00260 BMW-I.02 b)-do-labourchargesonly Each 20
a)Supplying&Fixingsolutionjointsupto50.8diaIstquality.
597 MAT-02148 BMW-I.03 Each 12

598 LAB-00261 BMW-I.04 b)-do-labourchargesonly Each 2


Chisellingthestonemasonrywallforfixingofwoodenblocksinclu
599 MAT-02149 BMW-I.05 Each 32
ding finishingasdirected bythe department
Chiselling the stone masonry wall and repairs as directed
600 MAT-02150 BMW-I.06 1Rm 152
bythedepartment.
Chisellingthebrickmasonrywallandrepairsasdirectedbythede
601 MAT-02151 BMW-I.07 1Rm 32
partment.
a) S & F NP telephonic shower spray set & valve mixer
602 MAT-02152 BMW-I.08 withrest and all fittings complete (ARK/ESSCO Each 1987
orequivalentmake)
603 LAB-00262 BMW-I.09 b)-do-labourchargesonly Each 425
604 MAT-02153 BMW-I.10 a)S &FNPshowerspray fancywith NPFlexiblepipe Each 532
605 LAB-00263 BMW-I.11 b)-do-labourchargesonly Each 141
606 MAT-02154 BMW-I.12 a)S &FNPcoverfor Nahany trap Each 30
607 LAB-00264 BMW-I.13 b)-do-labourchargesonly Each 20
608 MAT-02155 BMW-I.14 a)Paintingtheflushingtankwithwhiteenamelpaint Each 111

195
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
609 LAB-00265 BMW-I.15 b)-do-labourchargesonly Each 68
S&FinternalfittingsforflushtankParryplastwonderflushorequiv
610 MAT-02156 BMW-I.16 Each 727
alent
611 MAT-02157 BMW-I.17 Repairingandover haulingflushingtank Each 85
612 MAT-02158 BMW-I.18 a)Supplying &Fixing NP chainrubberandplugforbasin Each 39
613 LAB-00266 BMW-I.19 b)-do-labourchargesonly Each 7
a)S&F25.4mmdia&609.6mmlongaluminiumanodizedtowelro
614 MAT-02159 BMW-I.20 Each 153
dwithbrackets and aluminiumscrews
615 LAB-00267 BMW-I.21 b)-do-labourchargesonly Each 47
a)S&F19.04mmdia&609.6mmlongaluminiumanodized
616 MAT-02160 BMW-I.22 Each 136
towelrodwithbracketsandaluminiumscrews
617 LAB-00268 BMW-I.23 b)-do-labourchargesonly Each 71
a) S & F 609.6 mm long 127 mm wide plate glass shelf
618 MAT-02161 BMW-I.24 withsuperior quality aluminium railing complete with Each 195
aluminiumscrews
619 LAB-00269 BMW-I.25 b)-do-labourchargesonly Each 59
620 MAT-02162 BMW-I.26 a)S &F609.6 mm long 127mmwideplateglassshelfonly Each 63
621 LAB-00270 BMW-I.27 b)-do-labourchargesonly Each 12
622 MAT-02163 BMW-I.28 a)S &FNPsoap dish heavytypewith NP SCREWS Each 218
623 LAB-00271 BMW-I.29 b)-do-labourchargesonly Each 13
624 MAT-02164 BMW-I.30 a)S&FNPholderbracketswithscrews Each 45
625 LAB-00272 BMW-I.31 b)-do-labourchargesonly Each 15
a)S&FliquidsoapcontainerNPmetallicwithNPbracketsandscr
626 MAT-02165 BMW-I.32 Each 219
ews.
627 LAB-00273 BMW-I.33 b)-do-labourchargesonly Each 23
628 MAT-02166 BMW-I.34 a)S &F31.75 mmC.P TRAPS Each 286
629 LAB-00274 BMW-I.35 b)-do-labourchargesonly Each 47
630 MAT-02167 BMW-I.36 a)Supplying &fixing88.9 mm A.Ccowls Each 65
631 LAB-00275 BMW-I.37 b)-do-labourchargesonly Each 15
632 MAT-02168 BMW-I.38 a)Supplying&fixingA.CCowl63.5mmdia Each 44
633 LAB-00276 BMW-I.39 b)-do-labourchargesonly Each 12
634 MAT-02169 BMW-I.40 Removingandrefixing W.Cs Each 205
Removingandrefixingwashhandbasinsofanysizewithfittingsc
635 MAT-02170 BMW-I.41 Each 197
omplete
636 MAT-02171 BMW-I.42 a)S&F76.2x101.6 mmteakwoodblockcomplete Each 24
637 LAB-00277 BMW-I.43 b)-do-labourchargesonly Each 10
CuttingholesinC.C;basement&repairsLabourchargesonly
638 LAB-00278 BMW-I.44 Each 113

Cuttingholesinstonemasonry&basementandrepairsLabourch
639 LAB-00279 BMW-I.45 Each 76
argesonly
640 LAB-00280 BMW-I.46 Cuttingholes inBrick masonry&repairsLabourcharges Each
50
only

196
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
CuttingholesinRCCslabfloor&repairsLabourchargesonly
641 LAB-00281 BMW-I.47 Each 76

a)Supplying&Fixing12.7mmPVCconnectionwithbrassunionn
642 MAT-02172 BMW-I.48 Each 90
utC.Pcoated
643 LAB-00282 BMW-I.49 b)-do-labourchargesonly Each 18
644 MAT-02173 BMW-I.50 a)S&F12.7 mm.M.Pcouplings Each 32
645 LAB-00283 BMW-I.51 b)-do-labourchargesonly Each 12
646 MAT-02174 BMW-I.52 a)S &F19.05 mmM.Pcouplings Each 39
647 LAB-00284 BMW-I.53 b)-do-labourchargesonly Each 12
648 MAT-02175 BMW-I.54 a)S&FMPcoupling 25.4 mmdia Each 86
LAB-00285 b)-do-labourchargesonly Each 12
649 MAT-02176 BMW-I.55 a)S &FPVCRubberadopterforLLCandbend Each 18
650 LAB-00286 BMW-I.56 b)-do-labourchargesonly Each 8
651 MAT-02177 BMW-I.57 a)S&F31.75 mm Brassunionnuts Each 32
652 LAB-00287 BMW-I.58 b)-do-labourchargesonly Each 7
653 MAT-02178 BMW-I.59 a)S&F38.1mm Brassunionnuts Each 35
654 LAB-00288 BMW-I.60 b)-do-labourchargesonly Each 10
a) Constructing Brick masonry chamber over the gully
655 MAT-02179 BMW-I.61 trapor peet valve and fitted with 304.8 x 228.6 m size CI Each 442
frameand hingedcover.
656 LAB-00289 BMW-I.62 b)-do-labourchargesonly Each 106
a)ConstructingBrickmasonrysupportforG.IpipewithC.M
657 MAT-02180 BMW-I.63 304.8x228.6x228.6mmsizeincludingplasteringandfinishingetc.c Each 72
omplete.
658 LAB-00290 BMW-I.64 b)-do-labourchargesonly Each 23
a)Supplying&fixing304.8x228.6mmCIframe&coverovergully
659 MAT-02181 BMW-I.65 Each 115
taps
660 LAB-00291 BMW-I.66 b)-do-labourchargesonly Each 37
661 MAT-02182 BMW-I.67 a)Supplying &fixingCI Nahanytrapgrating Each 20
662 LAB-00292 BMW-I.68 b)-do-labourchargesonly Each 12
663 MAT-02183 BMW-I.69 a)Supplying &fixingCIgullytrapgrating Each 46
664 LAB-00293 BMW-I.70 b)-do-labourchargesonly Each 12
a)Supplying&fixingvalvesforbrassballcocks25.4mmdia
665 MAT-02184 BMW-I.71 Each 18

666 LAB-00294 BMW-I.72 b)-do-labourchargesonly Each 10


667 MAT-02185 BMW-I.73 a)Supplying &fixing12.7 mvalveforbibtaporstopcocks Each 17
668 LAB-00295 BMW-I.74 b)-do-labourchargesonly Each 7
669 MAT-02186 BMW-I.75 a)Supplying &fixing19.05mvalveforbibtaporstop cocks Each 37
670 LAB-00296 BMW-I.76 b)-do-labourchargesonly Each 12

197
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
671 MAT-02187 BMW-I.77 Removing12.7mmGIpipe andrefixingthesame Mr. 61
672 MAT-02188 BMW-I.78 Removing19.05mmGIpipeandrefixingthe same Mr. 67
673 MAT-02189 BMW-I.79 Removing25.4mmGIpipe andrefixingthesame Mr. 101
674 MAT-02190 BMW-I.80 Removing38.1mmGIpipe andrefixingthesame Rm 127
675 MAT-02191 BMW-I.81 Removing50.8mmGIpipe andrefixingthesame Rm 149
676 MAT-02192 BMW-I.82 Cleaningthe W.Cwith acidand Vimpowder Each 41
677 MAT-02193 BMW-I.83 CleaningtheUrinalwith acidandVim power Each 41
678 MAT-02194 BMW-I.84 CleaningthewashbasinwithacidandVim powder Each 41
679 MAT-02195 BMW-I.85 CleaningtheE.W.Cwith acidandVimpower Each 41
Supplying&fixing914.4x457.2mmCI
680 MAT-02196 BMW-I.86 Each 1815
manholeframeandcover(lightweight) 30Kgs
Supplying&fixing602x602mmCImanholeframeandcover(light
681 MAT-02197 BMW-I.87 Each 2687
weight) 30Kgs
682 LAB-00297 BMW-I.88 b)-do-labourchargesonly Each 148
683 MAT-02198 BMW-I.89 a)Supplying &fixingCIstepsforseptictank. Each 60
684 LAB-00298 BMW-I.90 b)-do-labourchargesonly Each 12
a)Supplying&fixing50.8cmdiaC.I.Manholeframe&coverfor91
685 MAT-02199 BMW-I.91 Each 1175
4.4mmdiachamber(20 Kgs- Lightweight)
686 LAB-00299 BMW-I.92 b)-do-labourchargesonly Each 148
a) Supplying & fixing 50.8cm dia C.I. Man hole frame
687 MAT-02200 BMW-I.93 &cover for 914.4 mm dia chamber(Medium weight) as Each 2438
perIS:1726-40Kgs
688 LAB-00300 BMW-I.94 b)-do-labourchargesonly Each 377
Cost. 50.8 mm thick RCM baffle wall with 2.267 Kg steel
689 LAB-00301 BMW-I.95 &rabbitwiremeshinCM1:3withfinerenderinginneatcement 1Sqm 222
labourcharges Only
690 MAT-02201 BMW-I.96 a)Cost.50.8mmRCCpartitionwall 1Sqm 249
691 LAB-00302 BMW-I.97 b)-do-labourchargesonly 1Sqm 47
a)S&Fdoublelayerofbamboomattingtarredonbothsides. 10
692 MAT-02202 BMW-I.98 573
Sqm
b)-do-labourchargesonly 10
693 LAB-00303 BMW-I.99 130
Sqm
694 MAT-02203 BMW-I.100 Removingof 101.6m or76.2mmCI pipe 1RM 32
695 MAT-02204 BMW-I.101 a)Supplying &fixing76.2mm W.Iclamps Each 24
696 LAB-00304 BMW-I.102 b)-do-labourchargesonly Each 10
697 MAT-02205 BMW-I.103 a)Supplying &fixingNPcoathook Each 43
698 LAB-00305 BMW-I.104 b)-do-labourchargesonly Each 12
a)SupplyingandfixingTVshapemirrorwithplasticframesize609
699 MAT-02206 BMW-I.105 Each 474
.6mmx 457.2mm
700 LAB-00306 BMW-I.106 b)-do-labourchargesonly Each 123
701 MAT-02207 BMW-I.107 a)Supplying &fixingGIpipeplug ofsize 12.7 mm dia Each 9

198
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
702 LAB-00307 BMW-I.108 b)-do-labourchargesonly Each 1
703 MAT-02208 BMW-I.109 a)Supplying &fixing19.06mmdiaGIplug Each 13
704 LAB-00308 BMW-I.110 b)-do-labourchargesonly Each 1
705 MAT-02209 BMW-I.111 a)Supplyingand fixing38.1mmdiaof GIplug Each 65
706 LAB-00309 BMW-I.112 b)-do-labourchargesonly Each 10
707 MAT-02210 BMW-I.113 a)Supplying &fixing50.8mmdia ofGIPLUG Each 100
708 LAB-00310 BMW-I.114 b)-do-labourchargesonly Each 12
709 MAT-02211 BMW-I.115 a)Supplying &fixing76.2mmdia ofGIPLUG Each 180
710 LAB-00311 BMW-I.116 b)-do-labourchargesonly Each 20
711 MAT-02212 BMW-I.117 a)Supplying &fixingC.P flange. Each 24
712 LAB-00312 BMW-I.118 b)-do-labourchargesonly Each 8
a)Supplying&fixingstainlesssteelsinksize36"x18"(914.4x457.
713 MAT-02213 BMW-I.119 Each 6782
2mm)1mmthick withaccessories
714 LAB-00313 BMW-I.120 b)-do-labourchargesonly Each 536
a) Supplying & fixing SINGLE BOWL stainless steel
715 MAT-02214 BMW-I.121 sinksize 24"x18"x8 "(609.6 x 457.2 x 203.2mm) 1 mm thick Each 5345
withaccessories
716 LAB-00314 BMW-I.122 b)-do-labourchargesonly Each 520
a)Supplying&fixingstainlesssteelsinksize20"x18"x8"(508x45
717 MAT-02215 BMW-I.123 Each 4860
7.2x203.2mm)1 mmthickwithaccessories
718 MAT-02216 BMW-I.124 b)-do-labourchargesonly Each 476
Supplying & fixing 4 " x 24 " (101.6x609.6mm) white
719 MAT-02217 BMW-I.125 glazedporcelainchannelfixedinbrickmasonrywhitecementpoi Each 493
nting.
Supply&Fixingofsteelsurgicallongelbowactionhandle
720 MAT-02218 BMW-I.126 12.7mmdiabibcockIndianmakeheavytypeincludingallmaterial Each 894
s
Supply & fixing 2 1/2" (63.5mm) dia Sluice valve ISI
721 MAT-02219 BMW-I.127 markwith 2 Nos. flanges, 8 nos, 3/4" dia nuts & bolts and Each 4896
allnecessarywashersandpackingmaterialsetc.complete
722 MAT-02220 BMW-I.128 Supply &fixingporcelainP'trap Each 211
Supplying & fixing oval shape basin
723 MAT-02221 BMW-I.129 Each 2241
white(520x410mm)parryorequivalent
Supply&fixingRCCcover22"diawithnominalreinforcement3"thic
724 MAT-02222 BMW-I.130 Each 663
k andhooks forlifting
Supply&fixingcpspl.Gratingwithframeandcoverof1stquality
725 MAT-02223 BMW-I.131 Each 57

726 MAT-02224 BMW-I.132 Supply &fixing towelrod(CP)of 24"longand3/4"dia Each 357


727 MAT-02225 BMW-I.133 Supply &fixingofLLChandleset1stquality Each 71
MechanicalCleaningofwatersumpswithpumps&UVdisinfecting 1000
728 MAT-02226 BMW-I.134 49
Lit
729 MAT-02227 BMW-I.135 Supply &fixing4"diaCPthimblepipe:150mm long Each 373
730 MAT-02228 BMW-I.136 Supply &fixing4"diaCPthimblepipe:220mm long Each 558

199
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
731 MAT-02229 BMW-I.137 Supply &fixing4"diaCPthimblepipe:300mm long Each 744
732 MAT-02230 BMW-I.138 Supply &fixingCPlongbend Each 315
733 MAT-02231 BMW-I.139 Supply&fixingCPshortbend Each 158
Supplying&fixing15mmbibtapwithflangeChromeumplatedJaq
734 MAT-02232 BMW-I.140 Each 1554
uarmakequeenseries
Supply & fixing bib cock cum health faucet with 1 m
735 MAT-02233 BMW-I.141 longflexibletubeandwallhook Each
3938
ofJaquarmakequeenserieswith7years warranty
Chromeplated
Supply & fixing bib cock cum health faucet with 1 m
736 MAT-02234 BMW-I.142 longflexibletubeandwallhook Each 6622
ofJaquarmakequeenserieswith7years warranty:Ivorygold
Supply&fixingpillarcock
737 MAT-02235 BMW-I.143 Each 1632
JaquarmakeQueenserieswith7yearswarranty:Chromeplated
Supply&fixingpillarcock
738 MAT-02236 BMW-I.144 Each 2786
JaquarmakeQueenserieswith7yearswarranty:Ivorygold
Supply&fixingAngularstopcockswithwallflangeJaquarmakeQ
739 MAT-02237 BMW-I.145 Each 1611
ueenserieswith7yearswarranty:Chrome plated
Supply&fixingAngularstopcockswithwallflangeJaquarmakeQ
740 MAT-02238 BMW-I.146 Each 3119
ueenseries with7years warranty:Ivory gold
Supply & fixing Waste coupling 32 mm size full thread
741 MAT-02239 BMW-I.147 with80 mm heightJaquar make with 7 years warranty: Each 362
Chromeplated
Supply&fixingofBottletrapJaquarmakewith7yearswarranty:C
742 MAT-02240 BMW-I.148 Each 1540
hromeplated
Supply&fixingofBottletrapJaquarmakewith7yearswarranty:Iv
743 MAT-02241 BMW-I.149 Each 2603
orygold
Supply&Fixingcopperpipe450mmlongwithnuts&washersJaq
744 MAT-02242 BMW-I.150 Each 378
uarmakewith7yearswarranty:Chromeplated
Supply&Fixingcopperpipe450mmlongwithnuts&washersJaq
745 MAT-02243 BMW-I.151 Each 733
uarmake with 7yearswarranty:Ivory gold
Supply and fixing wall mirror with provision for over
746 MAT-02244 BMW-I.152 headshowerand115mmlongbendpipewithwallflangeJaquarm Each 4976
ake queen serieswith 7 yearswarranty:Chromeplated

Supply and fixing wall mirror with provision for over


747 MAT-02245 BMW-I.153 headshowerand115mmlongbendpipewithwallflangeJaquarm Each 7828
akequeenseries with7yearswarranty:Ivorygold
Supply & fixing overhead shower rose with revolving
748 MAT-02246 BMW-I.154 jointand 150 mm long swivel shower arm Jaquar make Each 2309
queenseries.with7yearswarranty:Chromeplated
Supply & fixing overhead shower rose with revolving
749 MAT-02247 BMW-I.155 jointand 150 mm long swivel shower arm Jaquar make Each 3383
queenseries.with7years warranty:IvoryGold
SupplyandFixingWallMixerwithTelephonicshowerarrangem
750 MAT-02248 BMW-I.156 entwithcrutchandflexiblepipeJaquarseriesIvory Each 13188
goldcolourforbath tub.with7 years warranty
751 MAT-02249 BMW-I.157 Supply&fixingBathtuboverflowsetcompletewithover Each 1606

200
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
flow cap, 450 mm Ball chain with rubber plug & union
bendwith brass nut Jaquar make, Ivory gold colour. with 7
yearswarranty
Supply & fixing sink cock with regular swinging spout
752 MAT-02250 BMW-I.158 withwall flange chromeplated Jaquar make Queen series Each 2307
with 7yearswarranty
Supply&fixingsoapdishJaquarmakequeenseries:with7years
753 MAT-02251 BMW-I.159 Each 1514
warranty:Chromeplated
Supply&fixingsoapdishJaquarmakequeenseries:with7years
754 MAT-02252 BMW-I.160 Each 2222
warranty:IvoryGold
Supply&fixingoftoiletpaperholderJaquarmakeQueenseries.w
755 MAT-02253 BMW-I.161 Each 1220
ith7years warranty:Chromeplated
Supply&fixingoftoiletpaperholderJaquarmakeQueenseries.w
756 MAT-02254 BMW-I.162 Each 2147
ith7years warranty:IvoryGold
Supply&FixingofTowelringJaquarmakeQueenserieswith
757 MAT-02255 BMW-I.163 Each 1147
7years warranty:Chromeplated
Supply&FixingofTowelringJaquarmakeQueenserieswith
758 MAT-02256 BMW-I.164 Each 1873
7years warranty:IvoryGold
Supply&Fixingoftowelcoathook
759 MAT-02257 BMW-I.165 Each 853
JaquarmakeQueenserieswith7years warranty:Chromeplated
Supply&Fixingoftowelcoathook
760 MAT-02258 BMW-I.166 Each 1765
JaquarmakeQueenserieswith7years warranty:IvoryGold
Supply&FixingofTowelrod24"JaquarmakeQueenseriesIvory
761 MAT-02259 BMW-I.167 Each 2927
goldcolour with7years warranty
Supply&FixingofTumblerholderJaquarmakeQueenseries,Iv
762 MAT-02260 BMW-I.168 Each 2051
orygoldcolour with7years warranty
Supply&fixingofGlassshelf22"JaquarmakeQueenseries,Ivory
763 MAT-02261 BMW-I.169 Each 4000
goldcolour with7years warranty
Supply & Fixing of Bibcock cum Health Faucet with 1m
764 MAT-02262 BMW-I.170 longtube and wall hook of Jaquar Continental series, Each 2902
ChromeFinish with7yearswarranty
Supply&FixingofBibcockJaquarContinentalseries,Chrome
765 MAT-02263 BMW-I.171 Each 853
Finishwith7yearswarranty
Supply&FixingofPillarcockJaquarContinentalseries,Chrome
766 MAT-02264 BMW-I.172 Each 1060
Finishwith7yearswarranty
Supply&FixingofAngularstopcockwithwallflangeJaquarConti
767 MAT-02265 BMW-I.173 Each 788
nentalseries, Chrome finishwith 7yearswarranty
SupplyfixingofWastecouplingJaquarmake,Chromefinishwith
768 MAT-02266 BMW-I.174 Each 343
7years warranty
Supply&FixingofBottleTrapJaquarmake,Chromefinishwith
769 MAT-02267 BMW-I.175 Each 1540
7years warranty
Supply&Fixingofcopperpipe450mmlongwithnuts&washersJa
770 MAT-02268 BMW-I.176 Each 343
quarmake,ChromeFinishwith7yearswarranty
Supply & Fixing of Wall Mixer with provision for
771 MAT-02269 BMW-I.177 overheadshower and 115mm long bend pipe with wall Each
flange 3727
JaquarmakeContinentalseries,Chromefinishwith7yearswarr
anty

201
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supply & Fixing of Exclusive overhead shower with
772 MAT-02270 BMW-I.178 190mmlong light body shower arm Jaquar make Continental Each 1592
series,Chrome finishwith7yearswarranty
Supply&Fixingwallmixerwithtelephonicshowerarrangement
773 MAT-02271 BMW-I.179 with crutch and telephone shower with Each 5203
flexibletubeJaquarmakeContinentalseriesChromecolourforb
ath tubwith7yearswarranty
Supply & Fixing bath tub over flow set complete with
774 MAT-02272 BMW-I.180 overflow cap,450mm ball chain with rubber plug 7 Union Each 1215
bendwith brass nuts Jaquar make, Chrome colour with 7
yearswarranty
Supply & Fixing Sink cock with regular swinging spout
775 MAT-02273 BMW-I.181 withflange chrome plated Jaquar make Continental series Each 1500
with 7yearswarranty
Supply&FixingsoapdishJaquarmakeContinentalseries,Chro
776 MAT-02274 BMW-I.182 Each 1181
me Finishwith7yearswarranty
Supply&FixingofToiletpaperholderJaquarmakeContinentalse
777 MAT-02275 BMW-I.183 Each 788
ries, Chrome finishwith 7yearswarranty
Supply&FixingofTowelRingJaquarmakeContinentalseries,C
778 MAT-02276 BMW-I.184 Each 907
hromefinishwith7yearswarranty
Supply&FixingDoublecoathookJaquarmakeContinentalserie
779 MAT-02277 BMW-I.185 Each 677
s,Chromefinishwith7yearswarranty
Supply&Fixingoftowelrail24''JaquarmakeContinentalseries,C
780 MAT-02278 BMW-I.186 Each 1464
hromefinishwith7yearswarranty
Supply&FixingofTumblerholderJaquarmakeContinentalserie
781 MAT-02279 BMW-I.187 Each 987
s,Chromefinishwith7yearswarranty
Supply&FixingofGlassshelf22''JaquarmakeContinentalseries
782 MAT-02280 BMW-I.188 Each 1941
,Chromefinishwith7yearswarranty
Supply & Fixing of Bibcock cum Health Faucet with 1m
783 MAT-02281 BMW-I.189 longtubeandwallhookofJaquarFlorentine(Quarterturn)series, Each 3472
ChromeFinish with7yearswarranty
Supply&FixingofBibcockJaquarFlorentine(Quarterturn)series,C
784 MAT-02282 BMW-I.190 Each 1171
hromeFinish with 7yearswarranty
Supply&FixingofPillarcockJaquarFlorentine(Quarterturn)s
785 MAT-02283 BMW-I.191 Each 1171
eries,ChromeFinishwith 7yearswarranty
Supply & Fixing of Angular stopcock with wall flange
786 MAT-02284 BMW-I.192 JaquarFlorentine( Quarter turn)series, Chrome finish with 7 Each 1152
yearswarranty
Supply&FixingofBottleTrapJaquarmake,Chromefinishwith
787 MAT-02285 BMW-I.193 Each 1540
7years warranty
Supply & Fixing of Wall Mixer with provision for
788 MAT-02286 BMW-I.194 overheadshower and 115mm long bend pipe with wall Each 4497
flange Jaquarmake Florentine(Quarter turn) series, Chrome
finish with 7yearswarranty
Supply&Fixingwallmixerwithtelephonicshowerarrangement
789 MAT-02287 BMW-I.195 with crutch and telephone shower with flexibletube Jaquar Each 6777
make Florentine(Quarter turn) series
Chromecolourforbathtubwith7years warranty

202
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supply & Fixing Sink cock with regular swinging spout
790 MAT-02288 BMW-I.196 withflange chrome plated Jaquar make Florentine(Quarter Each 1796
turn)serieswith7yearswarranty
Supply&FixingofRoseshowerwithrevolvingballjoint&115mm
791 MAT-02289 BMW-I.197 Each 1908
longshowerarmwith7yearswarranty
Supply & Fixing of Jaquar make chrome plated Metro
792 MAT-02290 BMW-I.198 poleflush valveconcealed type with cover plate 40mm size Each 3342
with 7yearswarranty
Supply&FixingofJaquarmakeSensotronicsensorfaucetforwas
793 MAT-02291 BMW-I.199 Each 13126
hbasin,Chrome platedwith7years warranty
Supply & fixing of Jaquar make Sensotronic concealed
794 MAT-02292 BMW-I.200 typeflushing valve for urinal complete set with installation Each 13126
boxwithcontrolcock,Chrome platedwith 7yearswarranty
Supply&fixingofJaquarmakeAutoclosingsystempillarcockfor
795 MAT-02293 BMW-I.201 Each 2175
washbasin,Chromeplatedwith 7yearswarranty
Supply&FixingofJaquarmakeAutoClosingsystemBibcock,Chro
796 MAT-02294 BMW-I.202 Each 2281
meplatedwith7years warranty

797 MAT-02295 BMW-I.203 ITEM DELETED

798 MAT-02296 BMW-I.204 ITEM DELETED

799 MAT-02297 BMW-I.205 ITEM DELETED

800 MAT-02298 BMW-I.206 ITEM DELETED

801 MAT-02299 BMW-I.207 ITEM DELETED

802 MAT-02300 BMW-I.208 ITEM DELETED

803 MAT-02301 BMW-I.209 ITEM DELETED

804 MAT-02302 BMW-I.210 ITEM DELETED

805 MAT-02303 BMW-I.211 ITEM DELETED

806 MAT-02304 BMW-I.212 ITEM DELETED

807 MAT-02305 BMW-I.213 ITEM DELETED

203
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)

808 MAT-02306 BMW-I.214


ITEM DELETED

S&FPolyethylene-Aluminium-Polyethylene(PE-AL-
PE)composite pressure pipes conforming to IS-15450-2004
withUV stabilized, carbon black for hot & cold water
supply,capabletowithstandpressureupto80Cincludingallspeci
809 MAT-02307 BMW-I.215 al composite fittings, plastic & brass blend inserts forelbows, 1RM
165
tees, reducers, couplers, connectors etc
completeincludingexcavatingtrenchesupto1.0Mdeeplayingpi
pes, fixing in position, testing, refilling excavated earth
andcommissioning etc16mmODpipe

S&FPolyethylene-Aluminium-Polyethylene(PE-AL-
PE)composite pressure pipes conforming to IS-15450-2004
withUV stabilized, carbon black for hot & cold
watersupply,capabletowithstandpressureupto80Cincludingal
810 MAT-02308 BMW-I.216 lspecial composite fittings, plastic & brass blend inserts 1RM
195
forelbows, tees, reducers, couplers, connectors etc
completeincludingexcavatingtrenchesupto1.0Mdeeplayingpi
pes, fixing in position, testing, refilling excavated earth
andcommissioning etc20mmODpipe

S&FPolyethylene-Aluminium-Polyethylene(PE-AL-
PE)composite pressure pipes conforming to IS-15450-2004
withUV stabilized, carbon black forhot & cold water
supply,capabletowithstandpressureupto80Cincludingallspeci
811 MAT-02309 BMW-I.217 al composite fittings, plastic & brass blend inserts forelbows, 1RM
237
tees, reducers, couplers, connectors etc
completeincludingexcavatingtrenchesupto1.0Mdeeplayingpi
pes, fixing in position, testing, refilling excavated earth
andcommissioning etc25mmODpipe

S&FPolyethylene-Aluminium-Polyethylene(PE-AL-
PE)composite pressure pipes conforming to IS-15450-2004
withUV stabilized, carbon black for hot & cold water
supply,capabletowithstandpressureupto80Cincludingallspeci
812 MAT-02310 BMW-I.218 al composite fittings, plastic & brass blend inserts forelbows, 1RM
306
tees, reducers, couplers, connectors etc
completeincludingexcavatingtrenchesupto1.0Mdeeplayingpi
pes, fixing in position, testing, refilling excavated earth
andcommissioning etc32mmODpipe

S&FPolyethylene-Aluminium-Polyethylene(PE-AL-
PE)composite pressure pipes conforming to IS-15450-2004
813 MAT-02311 BMW-I.219 withUV stabilized, carbon black for hot & cold water 1RM
supply,capabletowithstandpressureupto80Cincludingallspeci
alcompositefittings,plastic&brassblendinsertsfor
elbows, tees, reducers, couplers, connectors etc 392
completeincludingexcavatingtrenchesupto1.0Mdeeplayingpi
pes, fixing in position, testing, refilling excavated earth
andcommissioning etc40mmODpipe

204
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
SupplyandFixingofPremiummakeCPVCPipesandFittings to
meet the requirement of ASTM-D 2846 and areproduced in
CTS (Copper Tube Sizes 1/2" ton 2" AshirvadFlowgurard
SDR 11 and SDR 13.5 pipes are made
fromidentialCPVCcompoundshavingthesamephysicalProper
tiesforHot and ColdWater(IS15778:2007)
814 MAT-02312 BMW-I.220 15.90mmODPipe -SDR 13.5 1RM 56
815 MAT-02313 BMW-I.221 22.20mmODPipe -SDR 13.5 1RM 89
816 MAT-02314 BMW-I.222 28.60mmODPipe -SDR 13.5 1RM 129
817 MAT-02315 BMW-I.223 34.90mmODPipe -SDR 13.5 1RM 202
818 MAT-02316 BMW-I.224 41.30mmODPipe -SDR 13.5 1RM 279
819 MAT-02317 BMW-I.225 54mmODPipe-SDR13.5 1RM 458
820 MAT-02318 BMW-I.226 15.90mmODPipe -SDR 11 1RM 64
821 MAT-02319 BMW-I.227 22.20mmODPipe -SDR 11 1RM 97
822 MAT-02320 BMW-I.228 28.60mmODPipe -SDR 11 1RM 151
823 MAT-02321 BMW-I.229 34.90mmODPipe -SDR 11 1RM 240
824 MAT-02322 BMW-I.230 41.30mmODPipe -SDR 11 1RM 329
825 MAT-02323 BMW-I.231 54mmODPipe-SDR11 1RM 506
Supplyof20mmx1.9mmPN10/PPRPipeconformingtoDINStan
826 MAT-02324 BMW-I.232 1RM
dards8077/8078 conformingtoIS15801 43

Supplyof25mmx2.3mmPN10/PPRPipeconformingtoDINStan
827 MAT-02325 BMW-I.233 1RM
dards8077/8078 conformingtoIS15801 64

Supplyof32mmx2.9mmPN10/PPRPipeconformingtoDINStan
828 MAT-02326 BMW-I.234 1RM
dards8077/8079 conformingtoIS15801 101

Supplyof40mmx3.7mmPN10/PPRPipeconformingtoDINStan
829 MAT-02327 BMW-I.235 1RM
dards8077/8079 conformingtoIS15801 158

Supplyof50mmx4.6mmPN10/PPRPipeconformingtoDINStan
830 MAT-02328 BMW-I.236 1RM
dards8077/8080 conformingtoIS15801 283

Supplyof63mmx5.8mmPN10/PPRPipeconformingtoDINStan
831 MAT-02329 BMW-I.237 1RM
dards8077/8081 conformingtoIS15801 444

Supplyof75mmx6.8mmPN10/PPRPipeconformingtoDINStan
832 MAT-02330 BMW-I.238 1RM
dards8077/8082 conformingtoIS15801 618

Supplyof90mmx8.2mmPN10/PPRPipeconformingtoDINStan
833 MAT-02331 BMW-I.239 1RM
dards8077/8083 conformingtoIS15801 848

Supplyof110mmx10mmPN10/PPRPipeconformingtoDINSta
834 MAT-02332 BMW-I.240 1RM
ndards8077/8084 conformingtoIS15801 1256

Supplyof20mmx2.8mmPN16/PPRPipeconformingtoDINStan
835 MAT-02333 BMW-I.241 1RM
dards8077/8078 conformingtoIS15801 58

Supplyof25mmx3.5mmPN16/PPRPipeconformingtoDINStan
836 MAT-02334 BMW-I.242 1RM
dards8077/8078 conformingtoIS15801 89

205
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplyof32mmx4.4mmPN16/PPRPipeconformingtoDINStan
837 MAT-02335 BMW-I.243 1RM 144
dards8077/8079 conformingtoIS15801
Supplyof40mmx5.5mmPN16/PPRPipeconformingtoDINStan
838 MAT-02336 BMW-I.244 1RM 220
dards8077/8079 conformingtoIS15801
Supplyof50mmx6.9mmPN16/PPRPipeconformingtoDINStan
839 MAT-02337 BMW-I.245 1RM 395
dards8077/8080 conformingtoIS15801
Supplyof63mmx8.6mmPN16/PPRPipeconformingtoDINStan
840 MAT-02338 BMW-I.246 1RM 623
dards8077/8081conforming toIS15801
Supplyof75mmx10.3mmPN16/PPRPipeconformingtoDINSta
841 MAT-02339 BMW-I.247 1RM 880
ndards8077/8082 conformingtoIS15801
Supplyof90mmx12.3mmPN16/PPRPipeconformingtoDINSta
842 MAT-02340 BMW-I.248 1RM 1254
ndards8077/8083 conformingtoIS15801
Supplyof110mmx15.1mmPN16/PPRPipeconformingtoDINSt
843 MAT-02341 BMW-I.249 1RM 1879
andards8077/8084 conformingtoIS15801
Supplyof20mmx3.4mmPN20/PPRPipeconformingtoDINStan
844 MAT-02342 BMW-I.250 1RM 68
dards8077/8078 conformingtoIS15801
Supplyof25mmx4.2mmPN20/PPRPipeconformingtoDINStan
845 MAT-02343 BMW-I.251 1RM 104
dards8077/8078 conformingtoIS15801
Supplyof32mmx5.4mmPN20/PPRPipeconformingtoDINStan
846 MAT-02344 BMW-I.252 1RM 167
dards8077/8079 conformingtoIS15801
Supplyof40mmx6.7mmPN20/PPRPipeconformingtoDINStan
847 MAT-02345 BMW-I.253 1RM 257
dards8077/8079 conformingtoIS15801
Supplyof50mmx8.3mmPN20/PPRPipeconformingtoDINStan
848 MAT-02346 BMW-I.254 1RM 457
dards8077/8080 conformingtoIS15801
Supplyof63mmx10.5mmPN20/PPRPipeconformingtoDINSta
849 MAT-02347 BMW-I.255 1RM 721
ndards8077/8081 conformingtoIS15801
Supplyof75mmx12.5mmPN20/PPRPipeconformingtoDINSta
850 MAT-02348 BMW-I.256 1RM 1023
ndards8077/8082 conformingtoIS15801
Supplyof90mmx15mmPN20/PPRPipeconformingtoDINStan
851 MAT-02349 BMW-I.257 1RM 1390
dards8077/8083
Supplyof110mmx18.3mmPN20/PPRPipeconformingtoDINSt
852 MAT-02350 BMW-I.258 1RM 2189
andards8077/8084 conformingtoIS15801
Supplyof20mmPPRSocketconformingtoDINStandards8077/
853 MAT-02351 BMW-I.259 1RM 9
8084
Supplyof25mmPPRSocketconformingtoDINStandards8077/
854 MAT-02352 BMW-I.260 1RM 14
8085
Supplyof32mmPPRSocketconformingtoDINStandards8077/
855 MAT-02353 BMW-I.261 1RM 19
8086
Supplyof40mmPPRSocketconformingtoDINStandards8077/
856 MAT-02354 BMW-I.262 1RM 31
8087
Supplyof50mmPPRSocketconformingtoDINStandards8077/
857 MAT-02355 BMW-I.263 1RM 61
8088
Supplyof63mmPPRSocketconformingtoDINStandards8077/
858 MAT-02356 BMW-I.264 1RM 118
8089
Supplyof75mmPPRSocketconformingtoDINStandards8077/
859 MAT-02357 BMW-I.265 1RM 180
8090

206
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplyof90mmPPRSocketconformingtoDINStandards8077/
860 MAT-02358 BMW-I.266 1RM 344
8091
Supply of 110mm PPR Socket conforming to DIN
861 MAT-02359 BMW-I.267 1RM 613
Standards8077/8092
Supplyof32mmPPRCoreFlangeconformingtoDINStandards807
862 MAT-02360 BMW-I.268 Each 37
7/8086
Supplyof40mmPPRCoreFlangeconformingtoDINStandards807
863 MAT-02361 BMW-I.269 Each 59
7/8087
Supplyof50mmPPRCoreFlangeconformingtoDINStandards807
864 MAT-02362 BMW-I.270 Each 77
7/8088
Supplyof63mmPPRCoreFlangeconformingtoDINStandards807
865 MAT-02363 BMW-I.271 Each 122
7/8089
Supplyof75mmPPRCoreFlangeconformingtoDINStandards807
866 MAT-02364 BMW-I.272 Each 141
7/8090
Supplyof90mmPPRCoreFlangeconformingtoDINStandards807
867 MAT-02365 BMW-I.273 Each 362
7/8091
Supplyof110mmPPRCoreFlangeconformingtoDINStandards80
868 MAT-02366 BMW-I.274 Each 468
77/8092
Supplyof20mmPPRElbowconformingtoDINStandards8077/8
869 MAT-02367 BMW-I.275 Each 16
084
Supplyof25mmPPRElbowconformingtoDINStandards8077/8
870 MAT-02368 BMW-I.276 Each 20
085
Supplyof32mmPPRElbowconformingtoDINStandards8077/8
871 MAT-02369 BMW-I.277 Each 37
086
Supplyof40mmPPRElbowconformingtoDINStandards8077/8
872 MAT-02370 BMW-I.278 Each 66
087
Supplyof50mmPPRElbowconformingtoDINStandards8077/8
873 MAT-02371 BMW-I.279 Each 124
088
Supplyof63mmPPRElbowconformingtoDINStandards8077/8
874 MAT-02372 BMW-I.280 Each 241
089
Supplyof75mmPPRElbowconformingtoDINStandards8077/8
875 MAT-02373 BMW-I.281 Each 390
090
Supplyof90mmPPRElbowconformingtoDINStandards8077/8
876 MAT-02374 BMW-I.282 Each 726
091
Supplyof110mmPPRElbowconformingtoDINStandards8077/
877 MAT-02375 BMW-I.283 Each 1347
8092
Supplyof20mmPPRTeeconformingtoDINStandards8077/808
878 MAT-02376 BMW-I.284 Each 15
4
Supplyof25mmPPRTeeconformingtoDINStandards8077/808
879 MAT-02377 BMW-I.285 Each 25
5
Supplyof32mmPPRTeeconformingtoDINStandards8077/808
880 MAT-02378 BMW-I.286 Each 45
6
Supplyof40mmPPRTeeconformingtoDINStandards8077/808
881 MAT-02379 BMW-I.287 Each 79
7
Supplyof50mmPPRTeeconformingtoDINStandards8077/808
882 MAT-02380 BMW-I.288 Each 140
8

207
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplyof63mmPPRTeeconformingtoDINStandards8077/808
883 MAT-02381 BMW-I.289 Each 286
9
Supplyof75mmPPRTeeconformingtoDINStandards8077/809
884 MAT-02382 BMW-I.290 Each 560
0
Supplyof90mmPPRTeeconformingtoDINStandards8077/809
885 MAT-02383 BMW-I.291 Each 812
1
Supplyof110mmPPRTeeconformingtoDINStandards8077/80
886 MAT-02384 BMW-I.292 Each 1407
92
Supplyof20mmPPREndCapconformingtoDINStandards8077
887 MAT-02385 BMW-I.293 Each 6
/8084
Supplyof25mmPPREndCapconformingtoDINStandards8077
888 MAT-02386 BMW-I.294 Each 9
/8085
Supplyof32mmPPREndCapconformingtoDINStandards8077
889 MAT-02387 BMW-I.295 Each 19
/8086
Supplyof40mmPPREndCapconformingtoDINStandards8077
890 MAT-02388 BMW-I.296 Each 31
/8087
Supplyof50mmPPREndCapconformingtoDINStandards8077
891 MAT-02389 BMW-I.297 Each 55
/8088
Supplyof63mmPPREndCapconformingtoDINStandards8077
892 MAT-02390 BMW-I.298 Each 118
/8089
Supplyof75mmPPREndCapconformingtoDINStandards8077
893 MAT-02391 BMW-I.299 Each 198
/8090
Supplyof90mmPPREndCapconformingtoDINStandards8077
894 MAT-02392 BMW-I.300 Each 315
/8091
Supplyof110mmPPREndCapconformingtoDINStandards8077/
895 MAT-02393 BMW-I.301 Each 623
8092
Supplyof25mmx20mmPPRReducerconformingtoDINStanda
896 MAT-02394 BMW-I.302 Each 11
rds8077/8092
Supplyof32mmx25mmPPRReducerconformingtoDINStanda
897 MAT-02395 BMW-I.303 Each 20
rds8077/8092
Supplyof32mmx20mmPPRReducerconformingtoDINStanda
898 MAT-02396 BMW-I.304 Each 19
rds8077/8092
Supplyof40mmx32mmPPRReducerconformingtoDINStanda
899 MAT-02397 BMW-I.305 Each 32
rds8077/8092
Supplyof40mmx25mmPPRReducerconformingtoDINStanda
900 MAT-02398 BMW-I.306 Each 31
rds8077/8092
Supplyof40mmx20mmPPRReducerconformingtoDINStanda
901 MAT-02399 BMW-I.307 Each 31
rds8077/8092
Supplyof50mmx20mmPPRReducerconformingtoDINStanda
902 MAT-02400 BMW-I.308 Each 48
rds8077/8092
Supplyof50mmx25mmPPRReducerconformingtoDINStanda
903 MAT-02401 BMW-I.309 Each 49
rds8077/8092
Supplyof50mmx32mmPPRReducerconformingtoDINStanda
904 MAT-02402 BMW-I.310 Each 49
rds8077/8092
Supplyof50mmx40mmPPRReducerconformingtoDINStanda
905 MAT-02403 BMW-I.311 Each 50
rds8077/8092

208
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplyof63mmx20mmPPRReducerconformingtoDINStanda
906 MAT-02404 BMW-I.312 Each 109
rds8077/8092
Supplyof63mmx25mmPPRReducerconformingtoDINStanda
907 MAT-02405 BMW-I.313 Each 109
rds8077/8092
Supplyof63mmx32mmPPRReducerconformingtoDINStanda
908 MAT-02406 BMW-I.314 Each 110
rds8077/8092
Supplyof63mmx40mmPPRReducerconformingtoDINStanda
909 MAT-02407 BMW-I.315 Each 111
rds8077/8092
Supplyof63mmx50mmPPRReducerconformingtoDINStanda
910 MAT-02408 BMW-I.316 Each 112
rds8077/8092
Supplyof75mmx40mmPPRReducerconformingtoDINStanda
911 MAT-02409 BMW-I.317 Each 162
rds8077/8092
Supplyof75mmx50mmPPRReducerconformingtoDINStanda
912 MAT-02410 BMW-I.318 Each 163
rds8077/8092
Supplyof75mmx63mmPPRReducerconformingtoDINStanda
913 MAT-02411 BMW-I.319 Each 207
rds8077/8092
Supplyof90mmx63mmPPRReducerconformingtoDINStanda
914 MAT-02412 BMW-I.320 Each 395
rds8077/8092
Supplyof90mmx75mmPPRReducerconformingtoDINStanda
915 MAT-02413 BMW-I.321 Each 419
rds8077/8092
Supplyof110mmx63mmPPRReducerconformingtoDINStand
916 MAT-02414 BMW-I.322 Each 528
ards8077/8092
Supplyof110mmx75mmPPRReducerconformingtoDINStand
917 MAT-02415 BMW-I.323 Each 615
ards8077/8092
Supplyof110mmx90mmPPRReducerconformingtoDINStand
918 MAT-02416 BMW-I.324 Each 662
ards8077/8092
Supplyof25mmx20mmx25mmPPRReducerTeeconforming
919 MAT-02417 BMW-I.325 Each 31
toDINStandards 8077/8092
Supplyof32mmx25mmx32mmPPRReducerTeeconforming
920 MAT-02418 BMW-I.326 Each 54
toDINStandards 8077/8092
Supplyof32mmx20mmx32mmPPRReducerTeeconforming
921 MAT-02419 BMW-I.327 Each 54
toDINStandards 8077/8092
Supplyof40mmx20mmx40mmPPRReducerTeeconforming
922 MAT-02420 BMW-I.328 Each 89
toDINStandards 8077/8092
Supplyof40mmx25mmx40mmPPRReducerTeeconforming
923 MAT-02421 BMW-I.329 Each 90
toDINStandards 8077/8092
Supplyof40mmx32mmx40mmPPRReducerTeeconforming
924 MAT-02422 BMW-I.330 Each 93
toDINStandards 8077/8092
Supplyof50mmx20mmx50mmPPRReducerTeeconforming
925 MAT-02423 BMW-I.331 Each 129
toDINStandards 8077/8092
Supplyof50mmx25mmx50mmPPRReducerTeeconforming
926 MAT-02424 BMW-I.332 Each 130
toDIN Standards 8077/8092
Supplyof50mmx32mmx50mmPPRReducerTeeconforming
927 MAT-02425 BMW-I.333 Each 134
toDINStandards 8077/8092
Supplyof50mmx40mmx50mmPPRReducerTeeconforming
928 MAT-02426 BMW-I.334 Each 135
toDINStandards8077/8092

209
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplyof63mmx20mmx63mmPPRReducerTeeconforming
929 MAT-02427 BMW-I.335 Each 372
toDINStandards 8077/8092
Supplyof63mmx25mmx63mmPPRReducerTeeconforming
930 MAT-02428 BMW-I.336 Each 374
toDINStandards 8077/8092
Supplyof63mmx32mmx63mmPPRReducerTeeconforming
931 MAT-02429 BMW-I.337 Each 380
toDINStandards 8077/8092
Supplyof63mmx40mmx63mmPPRReducerTeeconforming
932 MAT-02430 BMW-I.338 Each 386
toDINStandards 8077/8092
Supplyof63mmx50mmx63mmPPRReducerTeeconforming
933 MAT-02431 BMW-I.339 Each 392
toDINStandards 8077/8092
Supplyof75mmx50mmx75mmPPRReducerTeeconforming
934 MAT-02432 BMW-I.340 Each 526
toDINStandards 8077/8092
Supplyof75mmx63mmx75mmPPRReducerTeeconforming
935 MAT-02433 BMW-I.341 Each 535
toDINStandards 8077/8092
Supplyof90mmx50mmx90mmPPRReducerTeeconforming
936 MAT-02434 BMW-I.342 Each 708
toDINStandards 8077/8092
Supplyof90mmx63mmx90mmPPRReducerTeeconforming
937 MAT-02435 BMW-I.343 Each 753
toDINStandards 8077/8092
Supplyof110mmx75mmx110mmPPRReducerTeeconformin
938 MAT-02436 BMW-I.344 Each 1284
g toDINStandards 8077/8092
Supplyof110mmx90mmx110mmPPRReducerTeeconformin
939 MAT-02437 BMW-I.345 Each 1335
g toDINStandards 8077/8092
Supplyof20mmx½”PPRFemaleThreadedAdaptorconforming
940 MAT-02438 BMW-I.346 Each 99
toDINStandards 8077/8092
Supplyof25mmx½”PPRFemaleThreadedAdaptorconforming
941 MAT-02439 BMW-I.347 Each 101
toDINStandards 8077/8092
Supplyof25mmx¾”PPRFemaleThreadedAdaptorconforming
942 MAT-02440 BMW-I.348 Each 177
toDINStandards 8077/8092
Supplyof32mmx½”PPRFemaleThreadedAdaptorconforming
943 MAT-02441 BMW-I.349 Each 181
toDINStandards 8077/8092
Supplyof32mmx¾”PPRFemaleThreadedAdaptorconforming
944 MAT-02442 BMW-I.350 Each 186
toDINStandards 8077/8092
Supplyof32mmx1"PPRFemaleThreadedAdaptorconforming
945 MAT-02443 BMW-I.351 Each 288
toDINStandards 8077/8092
Supplyof40mmx1¼”PPRFemaleThreadedAdaptorconforming
946 MAT-02444 BMW-I.352 Each 426
toDINStandards 8077/8092
Supplyof50mmx1½”PPRFemaleThreadedAdaptorconforming
947 MAT-02445 BMW-I.353 Each 595
toDINStandards 8077/8092
Supplyof63mmx2"PPRFemaleThreadedAdaptorconforming
948 MAT-02446 BMW-I.354 Each 791
toDINStandards 8077/8092
Supplyof75mmx2½”PPRFemaleThreadedAdaptorconforming
949 MAT-02447 BMW-I.355 Each 1526
toDINStandards 8077/8092
Supplyof20mmx½”PPRMaleThreadedAdaptorconforming
950 MAT-02448 BMW-I.356 Each 153
toDINStandards 8077/8092
Supplyof25mmx½”PPRMaleThreadedAdaptorconforming
951 MAT-02449 BMW-I.357 Each 158
toDINStandards 8077/8092

210
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplyof25mmx¾”PPRMaleThreadedAdaptorconforming
952 MAT-02450 BMW-I.358 Each 231
toDINStandards 8077/8092
Supplyof32mmx¾”PPRMaleThreadedAdaptorconforming
953 MAT-02451 BMW-I.359 Each 241
toDIN Standards 8077/8092
Supplyof32mmx1"PPRMaleThreadedAdaptorconforming
954 MAT-02452 BMW-I.360 Each 448
toDINStandards 8077/8092
Supplyof40mmx1¼”PPRMaleThreadedAdaptorconforming
955 MAT-02453 BMW-I.361 Each 525
toDINStandards8077/8092
Supplyof50mmx1½”PPRMaleThreadedAdaptorconforming
956 MAT-02454 BMW-I.362 Each 734
toDINStandards 8077/8092
Supplyof63mmx2"PPRMaleThreadedAdaptorconforming
957 MAT-02455 BMW-I.363 Each 1129
toDINStandards 8077/8092
Supplyof75mmx2½”PPRMaleThreadedAdaptorconforming
958 MAT-02456 BMW-I.364 Each 1806
toDINStandards 8077/8092
Supplyof20mmx½”PPRFemaleThreadedElbowconforming
959 MAT-02457 BMW-I.365 Each 106
toDINStandards 8077/8092
Supplyof25mmx½”PPRFemaleThreadedElbowconforming
960 MAT-02458 BMW-I.366 Each 110
toDINStandards 8077/8092
Supplyof25mmx¾”PPRFemaleThreadedElbowconforming
961 MAT-02459 BMW-I.367 Each 170
toDINStandards 8077/8092
Supplyof32mmx½”PPRFemaleThreadedElbowconforming
962 MAT-02460 BMW-I.368 Each 163
toDINStandards 8077/8092
Supplyof32mmx¾”PPRFemaleThreadedElbowconforming
963 MAT-02461 BMW-I.369 Each 190
toDINStandards 8077/8092
Supplyof32mmx1"PPRFemaleThreadedElbowconforming
964 MAT-02462 BMW-I.370 Each 318
toDINStandards 8077/8092
Supplyof20mmx½”PPRMaleThreadedElbowconforming
965 MAT-02463 BMW-I.371 Each 158
toDINStandards 8077/8092
Supplyof25mmx½”PPRMaleThreadedElbowconforming
966 MAT-02464 BMW-I.372 Each 174
toDINStandards 8077/8092
Supplyof25mmx¾”PPRMaleThreadedElbowconforming
967 MAT-02465 BMW-I.373 Each 230
toDINStandards 8077/8092
Supplyof32mmx½”PPRMaleThreadedElbowconforming
968 MAT-02466 BMW-I.374 Each 220
toDINStandards 8077/8092
Supplyof32mmx1"PPRMaleThreadedElbowconformingtoDI
969 MAT-02467 BMW-I.375 Each 476
NStandards 8077/8092
Supplyof20mmx½”PPRFemaleThreadedTeeconforming
970 MAT-02468 BMW-I.376 Each 102
toDINStandards 8077/8092
Supplyof25mmx½”PPRFemaleThreadedTeeconforming
971 MAT-02469 BMW-I.377 Each 112
toDINStandards 8077/8092
Supplyof25mmx¾”PPRFemaleThreadedTeeconforming
972 MAT-02470 BMW-I.378 Each 186
toDIN Standards 8077/8092
Supplyof32mmx½”PPRFemaleThreadedTeeconforming
973 MAT-02471 BMW-I.379 Each 197
toDINStandards 8077/8092
Supplyof32mmx¾”PPRFemaleThreadedTeeconforming
974 MAT-02472 BMW-I.380 Each 220
toDINStandards8077/8092

211
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplyof32mmx1"PPRFemaleThreadedTeeconforming
975 MAT-02473 BMW-I.381 Each 310
toDINStandards 8077/8092
Supplyof20mm x½” PPR Male Threaded
976 MAT-02474 BMW-I.382 Each 159
TeeconformingtoDINStandards 8077/8092
Supplyof25mmx½”PPRMaleThreadedTeeconformingtoDIN
977 MAT-02475 BMW-I.383 Each 170
Standards 8077/8092
Supplyof25mmx¾”PPRMaleThreadedTeeconformingtoDIN
978 MAT-02476 BMW-I.384 Each 243
Standards 8077/8092
Supplyof32mmx½”PPRMaleThreadedTeeconformingtoDIN
979 MAT-02477 BMW-I.385 Each 250
Standards 8077/8092
Supply of 32mm x¾”PPR Male Threaded Tee conforming
980 MAT-02478 BMW-I.386 Each 263
toDINStandards8077/8092
Supplyof32mmx1"PPRMaleThreadedTeeconformingtoDINS
981 MAT-02479 BMW-I.387 Each 486
tandards 8077/8092
Supplyof20mmx½”PPRFemaleThreadedUnionconforming
982 MAT-02480 BMW-I.388 Each 410
toDINStandards 8077/8092
Supply of 25mm x¾”PPR Female Threaded
983 MAT-02481 BMW-I.389 Each 615
Unionconforming toDINStandards 8077/8092
Supply of 32mm x1”PPR Female Threaded
984 MAT-02482 BMW-I.390 Each 821
Unionconforming toDINStandards 8077/8092
Supplyof40mmx1¼”PPRFemaleThreadedUnionconforming
985 MAT-02483 BMW-I.391 Each 1150
toDIN Standards 8077/8092
Supplyof50mmx1½”PPRFemaleThreadedUnionconforming
986 MAT-02484 BMW-I.392 Each 1848
toDINStandards 8077/8092
Supplyof63mmx2”PPRFemaleThreadedUnionconforming
987 MAT-02485 BMW-I.393 Each 2935
toDIN Standards 8077/8092
Supplyof20mmx½”PPRMaleThreadedUnionconforming
988 MAT-02486 BMW-I.394 Each 470
toDINStandards 8077/8092
Supplyof25mmx¾”PPRMaleThreadedUnionconformingtoDI
989 MAT-02487 BMW-I.395 Each 625
NStandards8077/8092
Supplyof32mmx1”PPRMaleThreadedUnionconformingtoDIN
990 MAT-02488 BMW-I.396 Each 821
Standards 8077/8092
Supply of 40mm x1¼”PPR Male Threaded
991 MAT-02489 BMW-I.397 Each 1025
Unionconforming toDINStandards 8077/8092
Supplyof50mmx1½”PPRMaleThreadedUnionconforming
992 MAT-02490 BMW-I.398 Each 1950
toDINStandards 8077/8092
Supply of 63mm x 2” PPR Male Threaded Union
993 MAT-02491 BMW-I.399 Each 3285
conformingtoDINStandards 8077/8092
Supplyof20mmPPRUnionconformingtoDINStandards8077/8
994 MAT-02492 BMW-I.400 Each 89
092
Supplyof25mmPPRUnionconformingtoDINStandards8077/8
995 MAT-02493 BMW-I.401 Each 105
092
Supplyof32mmPPRUnionconformingtoDINStandards8077/8
996 MAT-02494 BMW-I.402 Each 173
092
Supplyof20mmPPRBallValveconformingtoDINStandards8077/
997 MAT-02495 BMW-I.403 Each 163
8092

212
BasicRate
CFMS for
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
Supplyof25mmPPRStand Ball Valve conforming to DIN
998 MAT-02496 BMW-I.404 Each 215
ards8077/8092
Supplyof32mmPPRStand Ball Valve conforming to DIN
999 MAT-02497 BMW-I.405 Each 227
ards8077/8092
Supplyof40mmPPRStand Ball Valve conforming to DIN
1000 MAT-02498 BMW-I.406 Each 463
ards8077/8092
Supplyof50mmPPRStand Ball Valve conforming to DIN
1001 MAT-02499 BMW-I.407 Each 540
ards8077/8092
Supplyof63mmPPRStand Ball Valve conforming to DIN
1002 MAT-02500 BMW-I.408 Each 874
ards8077/8092
Supplyof75mmPPRStand Ball Valve conforming to DIN
1003 MAT-02501 BMW-I.409 Each 1437
ards8077/8092
Supplyof90mmPPRStand Ball Valve conforming to DIN
1004 MAT-02502 BMW-I.410 Each 2054
ards8077/8092
Supplyof20mmPPRClampconformingtoDINStandards8077/
1005 MAT-02503 BMW-I.411 Each 9
8092
Supplyof25mmPPRClampconformingtoDINStandards8077/
1006 MAT-02504 BMW-I.412 Each 12
8092
Supplyof32mmPPRClampconformingtoDINStandards8077/
1007 MAT-02505 BMW-I.413 Each 15
8092
Supplyof40mmPPRClampconformingtoDINStandards8077/
1008 MAT-02506 BMW-I.414 Each 16
8092

Labourchargesforlaying,joining,welding,fixingandcommissio
ning the PPR pipes including all specials such ascouplers/
1009 LAB-00315 BMW-I.415 bends/ tees etc including fixing necessary fittingslike bends, 1RM 33
plugs, couplers, junctions, tees, etc with
weldingthejointasperstandard practice-upto 40 mmdia

Labourchargesforlaying,joining,welding,fixingandcommissio
ning the PPR pipes including all specials such ascouplers/
1010 LAB-00316 BMW-I.416 bends/ tees etc including fixing necessary fittingslike bends, 1RM
plugs, couplers, junctions, tees, etc with 56
weldingthejointasper standardpractice- above40mmdia

NOTE
Alltheitemstobeusedonworkareoffirstquality&ISI andas approvedby theEngineerInchargeof
1
thework.
Ratesgivenaboveare:
2 a)Rateforfinisheditemofwork
b)Labourchargesonly
RATES
3
SupplyRatesfor allthematerialsarebasedonmarketratesexcludingGST.
4 LABOURLabourchargesareincreasedbasedonproposalsandmarket rates
Colouredporcelainitems:50%extramaybe allowedonbasic costofwhite
5
porcelainitemsexcludingfittings
SSR Rates for Sanitary & water supply items are purely for guidance for the officers
6
forpreparationofestimatesvidePara113ofAPPWD code.Authoritywhopreparestheestimateis

213
BasicRatef
CFMS or
Sl.No Code ItemCode Descriptionofitem Unit
SoR 2021-
22(Rs.)
howeverresponsibleforproperratesasenvisagedinPara45ofAPPWD code.
LEGEND
"BMW"-X.XX "BMW"forWaterSupply&Sanitaryitems
XXX-"A".XX "A"for NameoftheSection
XXX-X."01" "01"for SerialNumberoftheItem

Note:-

1) AllMaterialsconformingtoISIorrelevantInternationalStandards shall be
used in all CIVIL, Water Supply &
SanitaryFittings,ElectricalandElectro-MechanicalWorks.

2) Concerned departments shall approve the materials either fromthe


manufacturer or from its authorized /certified dealer only andalsoto
approve the brands of the products / materialsto
beadoptedintheirestimatesattheirend.Incasecommonapproval is
required by the committee, concerned authority
shallproposewithallthedetailsafterthoroughverification,tothecommitte
e forconsideringthe proposal.

3) SSR rates forCivil and Water supply & Sanitary items


arepurelyforguidanceoftheofficersinpreparationofestimatesvidepara1
13ofAPPWDCode.Authoritywhopreparestheestimate
is,howeverresponsible for proper rates as envisagedinPara45
ofAPPWDCode.

4) Therates published in the Buildings SoR 2021-


22aretheceilingratesonlyandtheestimatepreparingauthoritiesarerespo
nsible for the correctness and reasonableness of the ratesand
technicalspecificationsadoptedintheestimates.

Page214
List of Recommended brands/Manufacturers for guidance of field
engineers :--
NOTE :
This list of popular/reputed brands are recommended for guidance. The concerned Engineer shall
from time to time ensure their approvals with respect to quality / approvals from standard
institutions and use in the estimate of the works. The Engineer can exercise his/her discretion in
selection while using other than these listed brands on satisfaction of their eligibility with respect
to ISI or such standard institutional approvals, durability and record/reputation of that product.
Sl.
SECTION NAMES OF THE RECOMMENDED BRAND/ MANUFACTURER/ SUPPLIER
No
A SECTION S.W.G. PIPES & FITTINGS
1. SUPPLY & LAYING OF SWG PIPES - Any ISI Brand
2. S.W.G. FITTINGS - Any ISI Brand
D SECTION VITREOUS CHINAWARE - SANITARY APPLIANCES
1. INDIAN WATER CLOSETS - Hindustan Sanitary ware/ Parryware/ Neycer/
CERA/Jaquar / Somany, Watertec, Kerovit by Kajaria, Prayag Polymers
2. FLOOR MOUNTED EWC - Hindustan Sanitary ware/ Parryware/ Neycer/
CERA/Jaquar / Somany, Watertec, Kerovit by Kajaria, Prayag Polymers
3. WALL MOUNTED EWC - Hindustan Sanitary ware/ Parryware/ Neycer/ CERA
/Jaquar/ Somany, Watertec, Kerovit by Kajaria, Prayag Polymers
4. CISTERNS FOR WATER CLOSETS - Hindustan Sanitary ware/ Parryware/ Neycer/
CERA /Jaquar / Somany, Watertec, Kerovit by Kajaria, Prayag Polymers
5. PLASTIC SEATS FOR WATER CLOSETS - Hindustan Sanitary ware/ Parryware/
Neycer/ CERA /Jaquar / Somany, Watertec, Kerovit by Kajaria, Prayag Polymers
6. WASH HAND BASINS - Hindustan Sanitary ware/ Parryware/ Neycer/ CERA /Jaquar
/ Somany, Watertec, Kerovit by Kajaria/ DEC Industries PVT LTD, Prayag Polymers
7. URINALS - Hindustan Sanitary ware/ Parryware/ Neycer/ CERA /Jaquar / Somany,
Naturesani, Watertec, Kerovit by Kajaria, Prayag Polymers
E SECTION CP FITTINGS - TAPS/ FAUCETS & ACCESSORIES
1. TAPS&FAUCETS - BIB TAPS - Seiko/ Senior/ Nice/ Senior/ Nice/ CERA/ Hindware -
PREMIUM MAKE - Jaquar/ Hindware/ Plumber/ Parryware/ H & R Johnson, Karla /
Essco / Somany/Kingston/Prayag Polymer/KUNCHAL ( Aluminium Udyog)/M/s
Sumo Polyplast Pvt. Ltd ( Sumolex), Watertec, Ambani, Kerovit by Kajaria, Austro,/
ESS ESS/ BATHSENSE/ ROYALE
2. XTAPS&FAUCETS - PILLAR TAPS - Seiko/ Senior/ Nice/ Senior/ Nice/ CERA/
Hindware- PREMIUM MAKE - Jaquar/ Hindware/ Plumber/ Parryware/ H & R
Johnson, Karla / Essco / Somany/ Kingston/Prayag Polymer/ KUNCHAL (
Aluminium Udyog)/ M/s Sumo Polyplast Pvt. Ltd ( Sumolex), Watertec, Ambani,
Kerovit by Kajaria, Austro/ ESS ESS/ BATHSENSE/ ROYALE
3. XTAPS&FAUCETS - OTHER TAPS & SPOUTS - Seiko/ Senior/ Nice/ Senior/
Nice/CERA/ Hindware - PREMIUM MAKE - Jaquar/ Hindware/ Plumber/
Parryware/ H & R Johnson, Karla / Essco /Somany/ Kingston/Prayag Polymer/
KUNCHAL ( Aluminium Udyog)/ M/s Sumo Polyplast Pvt. Ltd ( Sumolex) Watertec,
Ambani, Kerovit by Kajaria, Austro/ ESS ESS / BATHSENSE/ ROYALE
4. XSTOP & ANGLE VALVES - Seiko/ Senior/ Nice/ Senior/ Nice/ CERA/ Hindware -
PREMIUM MAKE - Jaquar/ Hindware/ Plumber/ Parryware/ H & R Johnson, Karla /
Essco / Somany/ Kingston/Prayag Polymer/ KUNCHAL ( Aluminium Udyog),
Watertec, Ambani, Kerovit by Kajaria, Austro/ ESS ESS/ BATHSENSE/ ROYALE
5. COMBINATION FAUCETS - Seiko/ Senior/ Nice/ Senior/ Nice/ CERA/ Hindware -
PREMIUM MAKE - Jaquar/ Hindware/ Plumber/ Parryware/ H & R Johnson, Karla /
Essco / Somany/ Kingston/Prayag Polymer/ KUNCHAL ( Aluminium Udyog)
Watertec, Ambani, Kerovit by Kajaria, Austro / ESS ESS/ BATHSENSE/ ROYALE
6. SHOWERS & FITTINGS - Seiko/ Senior/ Nice/ Senior/ Nice/ CERA/ Hindware -

Page215
Sl.
SECTION NAMES OF THE RECOMMENDED BRAND/ MANUFACTURER/ SUPPLIER
No
PREMIUM MAKE - Jaquar/ Hindware/ Plumber/ Parryware/ H & R Johnson, Karla /
Essco / Somany/ Kingston/Prayag Polymer/ KUNCHAL ( Aluminium Udyog),
Watertec, Ambani, Kerovit by Kajaria, Austro / ESS ESS/ BATHSENSE/ ROYALE
7. MISCELLANEOUS CP FITTINGS - Seiko/ Senior/ Nice/ Senior/ Nice/ CERA/
Hindware- PREMIUM MAKE - Jaquar/ Hindware/ Plumber/ Parryware/ H & R
Johnson, Karla / Essco / Somany/ Kingston/Prayag Polymer/ KUNCHAL (
Aluminium Udyog), Watertec, Ambani, Kerovit by Kajaria, Austro / ESS ESS/
BATHSENSE/ ROYALE
F SECTION G.I. PIPES & FITTINGS
1. G.I. PIPES - Tata/ JSW/ Oswal/ Zenith, PRECISION pipes &fittings
2. G.I. FITTINGS - HB / Kirti/ R-Brand, PRECISION pipes &fittings
3. BRONZE (COPPER ALLOY) VALVES - Zoloto/ R-Brand
G SECTION PVC PIPES & FITTINGS
1. PVC PIPES - Prince/Sudhakar/Kisan/Supreme/ Astral/ Finolex/ Ajay/
Ashirvad/Birla Aerocon/Trueflow by Hindware/Prayag Polymer, Watertec, Austro,
Nandi/ APOLLO PIPES LTD / DEC Industries PVT LTD, SENTINI Flo pipes,
PRECISION pipes & fittings
2. PVC FITTINGS- Prince/Sudhakar/Kisan/Supreme/ Astral/ Finolex/ Ajay/ Ashirvad/
Birla Aerocon/ Trueflow by Hindware/Prayag Polymer, Watertec, Austro, Nandi/
APOLLO PIPES LTD / DEC Industries PVT LTD , PRECISION pipes& fittings, Sentini
flo pipes and fittings
3. PVC PLUMBING ACCESSORIES - Prince/Sudhakar/Kisan/Supreme/ Astral/ Finolex/
Ajay/ Ashirvad/ Birla Aerocon/ Trueflow by Hindware, Watertec, Austro, Nandi/
APOLLO PIPES LTD , PRECISION pipes & fittings
4. PVC Tanks - Sintex, Aquatech, Nandi
5. PVC - LLC Cisterns - Parryware/ Slimlines/ CERA/ Hindware/Prayag Polymer/
APOLLO PIPES LTD
H SECTION CENTRIFUGAL CI PIPES & FITTNGS - IS : 1729
1. SUPPLY & LAYING OF CAST IRON PIPES - BIC/ NECO/ Jayaswal Neco
2. SUPPLYING & LAYING OF C.I. FITTINGS - BIC/ NECO/ Jayaswal Neco
I SECTION MISCELLANEOUS ITEMS
1. POLYETHYLENE-ALUMINIUM-POLYETHYLENE COMPOSITE PIPES - Kitec/
Kisan/ Uniflex/M/s Sumolex Polyplast Pvt. Ltd/ APOLLO PIPES LTD
2. CPVC PIPES - Supreme/ Ashirvad/ Astral/ Prince / Kisan / Ajay/Birla Aerocon/
Hindware Trueflo/Sudhakar/Prayag Polymer/ M/s Sumolex Polyplast Pvt. Ltd,
Watertec, Ambani, Austro, Nandi/ DEC Industries PVT LTD
3. PPR PIPES - Supreme/ Ashirvad/ Astral/ Prince/ Kisan / SFMC / KPT/ M/s Sumolex
Polyplast Pvt. Ltd

Page216
SCHEDULE OF RATES

ELECTRICAL
AND
ELECTRO-MECHANICAL WORKS

PART III -BUILDINGS


FOR THE YEAR
2021-22

1
PREAMBLE FOR ELECTRICAL WORKS

1. Overheads and Contractor profit and over Head Charges as mentioned in the Preamble for
Buildings SOR 2021-22 (Civil & Electrical) is applicable to all Original Electrical works, subject to the
fulfillment of the conditions mentioned in Para 3.0 of Preamble.
2. Municipal Area Allowance, Agency or Tribal area allowance or any such allowance on the labor
components is applicable to Electrical works as per the Para 4.0(1) of Preamble for Buildings
SOR 2021-22
3. The Electrical contractor is solely responsible for both quality and quantity.
4. Proposing specific make in the estimate from the SOR is within the scope of concerned field
officers based on the necessity and availability of materials in such areas.
5. In case of 2way points i.e. stair case point etc where two way switch control is necessary, an extra
at 50 % excess over each point shall be allowed
6. Where ever the light/fan point is provided at a height/length of 15 feet and above, then an extra
of 50% over the point rates shall be allowed.
7. The rates for common civil items including labour rates have to be adopted from prevailing SOR.
8. The rates for all types of electrical items proposed in SOR are exclusive of GST(basic rates).
9. The rates for items such as Refrigerators / A.C. Chilled Water plants / Water coolers and Video and
Audio Systems etc., have to be invariably followed based on the prevailing market rates, since the
rates and specification varies from manufacturer to manufacturer considerably. Hence, rates for
these items are not incorporated in the SOR. However, relevant data without rates is provided in
the standard schedule data for electrical works.
10. In case of any addition/alteration/rectification to the proposed SOR, the approval has to be
obtained from the Chief Engineer R&B Electrical. Temporary approvals for materials which are
under relevant specifications of the BIS and IEC can be given by the Superintending Engineer
(R&B) Electrical, duly obtaining approval from the Chief Engineer (R&B) Electrical.
11. The Superintending Engineer (R&B) Electrical will review the performance over the quality of
the makes proposed in the SOR from time to time and in case any inferior quality is observed
the same shall be brought to the notice of the Chief Engineer (R&B) Electrical to consider for
deletion from the SOR.
12. The schedule of rates is only for guidance of officers for preparation of estimates as per the Para
113 of APPWD code. The authority that sanctioned the estimate is however responsible for
adopting the proper rates in the estimates as envisaged in para 45 of APPWD code.
13. As per GO Ms No.51 Industries and commence (MSME) Dept Dt:01.06.2010, all the indenting
departments / Agents should invariably give preference to all local MSME which are
manufacturing quality products having ISO 9001 – 2000, GEM, BIS certification without
entertaining any other dealers / branded product manufacturers who have no production base in
Andhra Pradesh. Hence local manufacturers are considered as per Public Procurement order
2017,Ministry of Home afffairs, Government of India.

Chief Engineer(R&B) Electrical

2
SL. PAGE NOS
INDEX
NO. FROM TO
SECTION - 1
6 8
1.1 M.S.CONDUIT PIPES
9 11
1.2 PVCCONDUITPIPES
11 12
1.3 METAL BOXES FOR SWITCHBOARDS
12 13
1.4 T.W.BOARDS
13 17
1.5 COPPER FLEXIBLECABLES
17 18
SERVICEMAINSANDFLAT CABLES OF ISI FOR
1.6
SUBMERSIBLEMOTORS.
18 19
1.7 FLUSH TYPESWITCHES AND ACCESSORIES
19 22
1.8 MODULARSWITCHESAND ACCESSORIES

SECTION - 2
PANELMOUNTING SWITCHDISCONNECTOR FUSE 22 23
2.1
UNITS
23 23
ON LOAD CHANGE OVER SWITCHES.(OPEN
2.2
EXECUTION)
OFF LOAD CHANGEOVER SWITCHESIN SS 24 24
2.3
ENCLOUSURE
24 25
2.4 AUTOTRANSFER SWITCH

REWIRABLE/ DOUBLEBREAK SWITCHESIN SS 25 26


2.5
ENCLOSURE
26 26
2.6 HRCFUSELINKS (BOLTED TYPE)
26 27
2.7 PORCELAIN REWIRABLEFUSE UNITS.
27 27
2.8 VOLTAGESURGEPROTECTORS
28 34
2.9 PANELMOUNTING MCCBs/ ACBs/BUS DUCTs
34 35
2.10 MCBs
35 36
2.11 ISOLATORS
37 38
2.12 RCCBs
38 42
2.13 MCBDISTRIBUTIONBOARDS

SECTION - 3
42 43
3.1 STREET LIGHT LUMINAIRES
44 44
3.2 LED POST TOP LANTERN LUMINAIRES

3
SL. PAGE NOS
INDEX
NO. FROM TO
ACCESSORIES FORMV / SV /MH LUMINAIRES i.e., 44 45
3.3 COPPER BALLASTS,ENEGRY SAVING ELECTRONIC
BALLAST FOR STREETLIGHT,CAPACITORS,IGNITORS
45 46
3.4 LAMPS
46 47
3.5 AUTOMATIC STREETLIGHT CONTROLSYSTEMS
47 48
3.6 INTERNALLUMINAIRES
48 49
3.7 FLOURSCENT / CFL LAMPS/LED BULBS
63
3.8 LED LUMINAIRES
60
SECTION - 4
63 73
4.1 U.G.CABLES
73 74
4.2 CABLETRAYS
74 74
4.3 DOUBLEWALLCORRUGATED HDPEPIPE

SECTION - 5
74 76
5.1 FANS
76 78
5.2 WATER HEATERS (CONVENTIONAL & SOLAR)
78 79
5.3 ACCESSORIES FOR WATER HEATERS
5.4 PUMPSETS AND ITS CONTROL PANEL BOARDS 79 87

5.5 AIR CONDITIONERS(SPLIT/CASETTEE) 87 90

5.6 HVACSYSTEMS(VRV/VRF) 90 99

5.7 EVAPORATIVEAIR COOLING SYSTEM 99 99

5.8 STABILIZERS 100 100

5.9 REPAIRING OF FANS,COOLERS,PUMPS,MOTORS, 100 105


FRIDGES AND AIR CONDITIONERS

SECTION - 6
106 115
SWAGED,OCTOGANALANDGRP POLES AND
6.1
ACCESSORIES.
115 120
6.2 LT PANELAND ACCESSORIES
120 131
6.3 SUBSTATION EQUIPMENT AND TRANSFORMERS
131 133
6.4 MAINTENANCEAND REPAIRS OF TRANSFORMERS
133 137
6.5 OVERHEAD LINES AND LINE MATERIALS

4
SL. PAGE NOS
INDEX
NO. FROM TO
138 141
6.6 LIGHNING PROTECTIVE SYSTEMS
142 144
6.7 EARTHINGS
SECTION - 7
144 150
7.1 LOCALAREA NETWORK
150 150
7.2 RACEWAYS AND JUNCTION BOXES
151 161
7.3 7.4 & 7.5 COMPUTERS,PRINTERS, SCANNERS& EPABX

SECTION - 8
161 163
8.1 MISCELLANIOUS ITEMS
163 164
8.2 LEGEND PLATES
164 164
8.3 COPPER/ALUMINIUM/GI ITEMS
164 167
8.4 SMCTYPESUPPORTSFOR BUSBARS
167 168
8.5 LABOUR RATES

SECTION - 9
168 169
9.1 WIRELESS FIRE ALARAMSYSTEM
169 177
9.2 ADDRESSABLE - FIREALARAM SYSTEM
177 178
9.3 CONVENTIONAL - FIREALARAM SYSTEM
178 184
9.4 POWDER BASED FIRE EXTINGUISHERS
184 211
9.5 FIRE HYDRANT AND SPRINKLER SYSTEM

SECTION - 10
211 213
10.1 DIESEL GENERATORS

SECTION - 11
213 216
11.1 INVERTERS AND ONLINEUP S SYSTEMS

SECTION- 12
216 225
12.1 TEMPORARY ILLUMINATION
226 226
12.2 HIRING OF GENERATORS (TE-DG)

SECTION- 13
226 275
13 13.1 ,13.2 & 13.3 LIFTS& Dismantling
List of recommended Brands / manufacturers 276 293
A-I
294 300
A-II General Guide Lines

5
SCHEDULED RATES FOR ELETRICAL & ELECTRO MECHANICAL ITEMS SOR 2021-22

Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

SECTION - 1

1.1 M.S. CONDUIT PIPES

1 ELEC-1.1.1 Supply of ISI, ………... outer dia,…... thickness MS conduit pipe as per
lS-9537 Part ll .
Makes : As per list of recommended brands
MAT- a 20 mm ( 1.6 mm thick) 1 RM 99
02621
MAT- b 25 mm ( 1.6 mm thick) 1 RM 127
02622
MAT- c 32 mm ( 1.6 mm thick) 1 RM 182
02623
MAT- d 38 mm ( 2.0 mm thick) 1 RM 297
02624
MAT- e 50 mm ( 2.0 mm thick) 1 RM 380
02625
2 ELEC-1.1.2 Supply of ……….. MS Junction box normal range big size long neck.

MAT- a 19/20 mm 1 No 28
02626
MAT- b 25 mm 1 No 33
02627
MAT- c 32 mm 1 No 77
02628
MAT- d 40/38 mm 1 No 110
02629
MAT- e 50 mm 1 No 209
02630
3 ELEC-1.1.3 Supply of ……….MS Junction deep
box.
MAT- a 20/25 mm 1 No 72
02631
MAT- b 32 mm 1 No 127
02632
MAT- c 40 mm 1 No 154
02633
MAT- d 50 mm 1 No 187
02634
4 ELEC-1.1.4 Supply of ……….. MS Inspection
Bends.
MAT- a 19/20 mm 1 No 24
02635

6
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b 25 mm 1 No 28
02636
MAT- c 32 mm 1 No 61
02637
MAT- d 40/38 mm 1 No 88
02638
MAT- e 50 mm 1 No 187
02639
5 ELEC-1.1.5 Supply of ……... MS Inspection Tee.

MAT- a 19/20 mm 1 No 28
02640
MAT- b 25 mm 1 No 33
02641
MAT- c 32 mm 1 No 77
02642
MAT- d 40/38 mm 1 No 94
02643
MAT- e 50 mm 1 No 193
02644
6 ELEC-1.1.6 Supply of ………….. MS Inspection
Elbow.
MAT- a 19/20 mm 1 No 24
02645
MAT- b 25 mm 1 No 33
02646
MAT- c 32 mm 1 No 61
02647
MAT- d 40/38 mm 1 No 77
02648
MAT- e 50 mm 1 No 176
02649
7 ELEC-1.1.7 Supply of MS Inspection 10 Guage G.I. checknut of size …………..

MAT- a 19/20 mm 100 Nos 220


02650
MAT- b 25 mm 100 Nos 275
02651
MAT- c 32 mm 100 Nos 550
02652
MAT- d 40/38 mm 100 Nos 798
02653
MAT- e 50 mm 100 Nos 1331
02654

7
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
8 ELEC-1.1.8 Supply of ……………... Saddles with
Base.
MAT- a 19/20 mm 100 Nos 237
02655
MAT- b 25 mm 100 Nos 248
02656
MAT- c 32 mm 100 Nos 418
02657
MAT- d 40/38 mm 100 Nos 688
02658
MAT- e 50 mm 100 Nos 869
02659
9 ELEC-1.1.9 Supply of………...20 guage Saddles.

MAT- a 19/20 mm 100 Nos 121


02660
MAT- b 25 mm 100 Nos 165
02661
MAT- c 32 mm 100 Nos 264
02662
MAT- d 40/38 mm 100 Nos 341
02663
MAT- e 50 mm 100 Nos 418
02664
10 ELEC-1.1.10 Supply of ………... 16 Guage socket
coupler.
MAT- a 19/20 mm 12 Nos 66
02665
MAT- b 25 mm 12 Nos 88
02666
MAT- c 32 mm 12 Nos 143
02667
MAT- d 38 mm 12 Nos 187
02668
MAT- e 40mm 12 Nos 209
02669
MAT- f 50 mm 12 Nos 440
02670
11 ELEC-1.1.11 Supply of 19mm Ball Socket.

MAT- a 19 mm 12 Nos 253


02671

MAT- b 25 mm 12 Nos 385


02672

8
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

1.2 PVC CONDUIT PIPES

12 ELEC-1.2.1 Supply of ISI ………. outer dia heavy grade with IS:9537 part 3 FRLS
regid PVC pipe
Makes : As per list of recommended brands
MAT- a 20 mm(1.95 - 2.10)mm thickness 1 RM 28
02673
MAT- b 25 mm(2.00 - 2.20)mm thickness 1 RM 36
02674
13 ELEC-1.2.2 Supply of ISI …….. outer dia medium grade with IS:9537 part 3 FRLS
regid PVC pipe.
Makes : As per list of recommended brands

MAT- a 20mm (1.40 -1.55)mm thickness 1 RM 20


02675
MAT- b 25mm (1.60 -1.80)mm thickness 1 RM 28
02676
MAT- c 32mm (1.90 - 2.10)mm thickness 1 RM 43
02677
MAT- d 40mm (2.10 - 2.30)mm thickness 1 RM 58
02678
MAT- e 50mm (2.60 - 2.85)mm thickness 1 RM 83
02679
NOTE:Add 5% extra on above price for Red/Yellow/Blue/Black/Green Colour PVC
pipes for specific purpose Usage

14 ELEC-1.2.3 Supply of ISI ……….. width and 12.5mm height Casing and Caping.
Makes : As per list of recommended brands

MAT- a 19/20 mm 1 RM 22
02680
MAT- b 25mm 1 RM 33
02681
MAT- c 32mm 1 RM 39
02682
MAT- d 38/40mm 1 RM 64
02683
15 ELEC-1.2.4 Supply of ……... FRPP corrugated Flexible conduit pipe.
Makes : As per list of recommended brands
MAT- a 19/20 mm 1 RM 13
02684
MAT- b 25mm 1 RM 17
02685
MAT- c 32mm 1 RM 26
02686
MAT- d 38/40mm 1 RM 36

9
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

02687

MAT- e 50 mm 1 RM 59
02688
16 ELEC-1.2.5 Supply of ……….. PVC Flexible Couplings for FRPP Corrugated conduit
pipe .
Makes : As per list of recommended brands

MAT- a 19/20 mm 1 No 11
02689
MAT- b 25mm 1 No 17
02690
MAT- c 32mm 1 No 28
02691
MAT- d 40mm 1 No 33
02692
MAT- e 50 mm 1 No 61
02693
17 ELEC-1.2.6 Supply of…………. PVC Junction Boxes confirms to IS : 3419
Makes : As per list of recommended brands

MAT- a 19/20 mm 1 No 21
02694
MAT- b 25mm 1 No 22
02695
MAT- c 32mm 1 No 39
02696
MAT- d 40mm 1 No 41
02697
MAT- e 50 mm 1 No 55
02698
18 ELEC-1.2.7 Supply of ………...PVC deep Junction Boxes confirms to IS : 3419.
Makes : As per list of recommended brands

MAT- a 19/20 mm 1 No 25
02699
MAT- b 25mm 1 No 28
02700
MAT- c 32mm 1 No 44
02701
MAT- d 40/38 mm 1 No 48
02702
MAT- e 50 mm 1 No 70
02703
19 ELEC-1.2.8 Supply of ………………. PVC Bends.

10
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Makes : As per list of recommended brands

MAT- a 19/20 mm dia 1.5mm thick 1 No 7


02704
MAT- b 25mm dia 1.5mm thick 1 No 9
02705
MAT- c 32mm dia 2.0mm thick 1 No 20
02706
MAT- d 40 mm dia 2.0mm thick 1 No 22
02707
MAT- e 50 mm dia 2.0mm thick 1 No 32
02708
20 MAT- ELEC-1.2.9 Dummy Cover for PVC junction boxes 1 No 6
02709

1.3 HOT DIP GALVANIZED METAL


BOXES for switch boards
21 ELEC-1.3.1 Supply of………. Hot Dip galvanized 20/18 SWG Module box with
earthing terminal
MAT- a 1 or 2 1 No 63
02710
MAT- b 3 1 No 88
02711
MAT- c 4 1 No 105
02712
MAT- d 6 1 No 143
02713
MAT- e 8 or 9 1 No 187
02714
MAT- f 12 1 No 226
02715
METALLIC BOXES

22 ELEC-1.3.2 Supply of ……….18 SWG sheet steel boxes duly finished with two coats
of zinchromate redoxide
MAT- a 100mmx100x50mm 1 No 55
02716
MAT- b 175mmx100x60mm 1 No 66
02717
MAT- c 150mmx150x60mm 1 No 77
02718
MAT- d 200mmx150x60mm 1 No 88
02719
MAT- e 200mmx250x75mm 1 No 110

11
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

02720

MAT- f 250mmx300x75mm 1 No 193


02721
MAT- g 300mmx375x100mm 1 No 248
02722
1.4 T.W. BOARDS

23 ELEC-1.4.1 Supply of T.W.Deep Box of Size

MAT- a 4" x 4" 1 No 11


02723
MAT- b 4" x 7 1 No 20
02724
MAT- c 6" x 6" 1 No 22
02725
MAT- d 6" x 8" 1 No 33
02726
MAT- e 8" x 10" 1 No 55
02727
MAT- f 10" x 12" 1 No 77
02728
MAT- g 12" x 15" 1 No 121
02729
25 ELEC-1.4.2 Supply of Decolam Board of size

MAT- a 4" x 4" 1 No 17


02730
MAT- b 4" x 7 1 No 28
02731
MAT- c 6" x 6" 1 No 39
02732
MAT- d 6" x 8" 1 No 44
02733
MAT- e 8" x 10" 1 No 77
02734
MAT- f 10" x 12" 1 No 121
02735
MAT- g 12" x 15" 1 No 182
02736
26 ELEC-1.4.3 Supply of Peeta Boards of size

MAT- a 9" x 14" 1 No 55


02737
MAT- b 12" x 10" 1 No 61
02738

12
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 15" x 20" 1 No 209


02739
MAT- d 18" x 24" 1 No 303
02740
MAT- e 18" x 30" 1 No 374
02741
27 ELEC-1.4.4 Supply of No.8 Screws of

MAT- a 12mm. 100 Nos 66


02742
MAT- b 25mm. 100 Nos 83
02743
MAT- c 30mm. 100 Nos 99
02744
MAT- d 35/38mm. 100 Nos 110
02745
MAT- e 50mm 100 Nos 128
02746
MAT- f 63/75mm. 100 Nos 154
02747
1.5 COPPER FLEXIBLE CABLES
(AS PER IS:694)
28 ELEC-1.5.1 Supply of……….FRLS/ FRLS-H / HFFR PVC insulated 1100V grade as
per IS : 694 / 1990 specification for Copper cable.
Makes : As per list of recommended brands as category I
MAT- a 1.0 Sqmm 100 RM 1208
02748
MAT- b 1.5 Sqmm 100 RM 1737
02749
MAT- c 2.5 Sqmm 100 RM 2806
02750
MAT- d 4.0 Sqmm 100 RM 4284
02751
MAT- e 6.0 Sqmm 100 RM 6555
02752
MAT- f 10.0 Sqmm 100 RM 10120
02753
MAT- g 16.0 Sqmm 100 RM 15985
02754
29 ELEC-1.5.2 Supply of .................... FRLS / FRLS-H / HFFR / ZHFR PVC insulated
1100V grade as per IS : 694 / 1990 specification for Copper cable.
Makes : As per list of recommended brands as category II
MAT- a 1.0 Sqmm 100 RM 1064
02755

13
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b 1.5 Sqmm 100 RM 1518


02756
MAT- c 2.5 Sqmm 100 RM 2461
02757
MAT- d 4.0 Sqmm 100 RM 3795
02758
MAT- e 6.0 Sqmm 100 RM 5865
02759
MAT- f 10.0 Sqmm 100 RM 8913
02760
MAT- g 16.0 Sqmm 100 RM 14835
02761
30 ELEC-1.5.3 Supply of ………….. FRLS / FRLSH / ZHFR PVC insulated 1100V
grade as per IS : 694 / 1990 specification for Copper cable.
Makes : As per list of recommended brands as category III
MAT- a 1.0 Sqmm 100 RM 920
02762
MAT- b 1.5 Sqmm 100 RM 1288
02763
MAT- c 2.5 Sqmm 100 RM 2070
02764
MAT- d 4.0 Sqmm 100 RM 3105
02765
MAT- e 6.0 Sqmm 100 RM 4830
02766

MAT- f 10.0 Sqmm 100 RM 7648


02767
MAT- g 16.0 Sqmm 100 RM 11730
02768

SHEATHED FLEXIBLE COPPER


CABLES
31 ELEC-1.5.4 Supply of ……...PVC insulated and sheathed FRLS copper round cable
for voltage up to 1100V as per IS 694/1990.
Makes : As per list of recommended brands as category I
MAT- a Single Core 25 Sqmm 1 RM 253
05466
MAT- b Single Core 35 Sqmm 1 RM 357
05467
MAT- c Single Core 50 Sqmm 1 RM 506
05468
MAT- d Single Core 70 Sqmm 1 RM 690
05469
MAT- e 2 core 1.5 Sqmm 1 RM 52

14
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

02769

MAT- f 2 core 2.5 Sqmm 1 RM 81


02770
MAT- g 2 core 4.0 Sqmm 1 RM 109
02771
MAT- h 2 core 6 Sqmm 1 RM 167
05470
MAT- i 2 core 10 Sqmm 1 RM 242
05471
MAT- j 2 core 16 Sqmm 1 RM 288
05472
MAT- k 3 core 1.5 Sqmm 1 RM 69
02772
MAT- l 3 core 2.5 Sqmm 1 RM 115
02773
MAT- m 3 core 4.0 Sqmm 1 RM 161
02774
MAT- n 3 core 6 Sqmm 1 RM 201
05473
MAT- o 3 core 10 Sqmm 1 RM 265
05474
MAT- p 3 core 16 Sqmm 1 RM 426
05475
MAT- q 4 core 1.5 Sqmm 1 RM 92
02775
MAT- r 4 core 2.5 Sqmm 1 RM 144
02776
MAT- s 4 core 4.0 Sqmm 1 RM 219
02777
MAT- t 4 core 6 Sqmm 1 RM 322
05476
MAT- u 4 core 10 Sqmm 1 RM 495
05477
MAT- v 4 core 16 Sqmm 1 RM 627
05478
32 ELEC-1.5.5 Supply of ……...PVC insulated and sheathed FRLS copper round cable
for voltage up to 1100V as per IS 694/1990.
Makes : As per list of recommended brands as category II
MAT- a Single Core 25 Sqmm 1 RM 224
05479
MAT- b Single Core 35 Sqmm 1 RM 328
05480
MAT- c Single Core 50 Sqmm 1 RM 443

15
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

05481

MAT- d Single Core 70 Sqmm 1 RM 638


05482
MAT- e 2 core 1.5 Sqmm 1 RM 46
02778
MAT- f 2 core 2.5 Sqmm 1 RM 69
02779
MAT- g 2 core 4.0 Sqmm 1 RM 98
02780
MAT- h 2 core 6 Sqmm 1 RM 155
05483
MAT- i 2 core 10 Sqmm 1 RM 219
05484
MAT- j 2 core 16 Sqmm 1 RM 276
05485
MAT- k 3 core 1.5 Sqmm 1 RM 63
02781
MAT- l 3 core 2.5 Sqmm 1 RM 104
02782
MAT- m 3 core 4.0 Sqmm 1 RM 138
02783
MAT- n 3 core 6 Sqmm 1 RM 190
05486
MAT- o 3 core 10 Sqmm 1 RM 247
05487
MAT- p 3 core 16 Sqmm 1 RM 391
05488
MAT- q 4 core 1.5 Sqmm 1 RM 81
02784
MAT- r 4 core 2.5 Sqmm 1 RM 115
02785
MAT- s 4 core 4.0 Sqmm 1 RM 184
02786
MAT- t 4 core 6 Sqmm 1 RM 299
05489
MAT- u 4 core 10 Sqmm 1 RM 454
05490
MAT- v 4 core 16 Sqmm 1 RM 592
05491
33 MAT- ELEC-1.5.6 Supply of 23 / 0060 twin core twisted / 100 RM 1093
02787 flat heavy Copper wire.
Makes : As per list of recommended

16
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

brands.

1.6 SERVICE MAINS AND FLAT CABLE


FOR SUBMERSIBLE MOTORS.
34 ELEC-1.6.1 Supply of ……...WPSC (Weather Proof Single Core) ISI Alluminium
Wire.
Makes : As per list of recommended brands.
MAT- a 2.5 Sqmm 100 RM 759
02788
MAT- b 6 Sqmm 100 RM 1513
02789
MAT- c 10 Sqmm 100 RM 1650
02790
MAT- d 16 Sqmm 100 RM 2750
02791
35 ELEC-1.6.2 Supply of ……….WPTC (Weather Proof Twin Core) ISI Alluminium Wire.
Makes : As per list of recommended brands.
MAT- 6 Sqmm 100 RM 3080
02792
MAT- 10 Sqmm 100 RM 3724
02793
36 ELEC-1.6.3 Supply of 3 Core…………. Flat Copper cable of ISI for Submersible
Motors confirming to IS:694:1990.
Makes : As per list of recommended brands as category I
MAT- a 1.5 Sqmm 1 RM 63
02794
MAT- b 2.5 Sqmm 1 RM 92
02795
MAT- c 4.0 Sqmm 1 RM 144
02796

MAT- d 6.0 Sqmm 1 RM 207


02797
MAT- e 10.0 Sqmm 1 RM 328
02798
MAT- f 16.0 Sqmm 1 RM 431
02799
37 ELEC-1.6.4 Supply of 3 Core…………. Flat Copper cable of ISI for Submersible
Motors confirming to IS:694:1990.
Makes : As per list of recommended brands as category II
MAT- a 1.5 Sqmm 1 RM 58
02800
MAT- b 2.5 Sqmm 1 RM 83
02801

17
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 4.0 Sqmm 1 RM 127


02802
MAT- d 6.0 Sqmm 1 RM 184
02803
MAT- e 10.0 Sqmm 1 RM 299
02804
MAT- f 16.0 Sqmm 1 RM 391
02805
1.7 FLUSH TYPE SWITCHES AND
ACCESSORIES
38 ELEC-1.7.1 Supply of …………………..
Makes : As per list of recommended brands.

MAT- a 6A 1 Way flush type Swich. 1 No 17


02806
MAT- b 6A 2 Way flush type Swich. 1 No 21
02807
MAT- c 6A 2 pin flush type Socket. 1 No 20
02808
MAT- d 6A 3/2 pin flush type Socket with 1 No 26
02809 shutter.

MAT- e 6A flush type Neon Indicator. 1 No 20


02810
MAT- f 6A Triangle Plug Top of 1 No 33
02811
MAT- g 1 Way flush type Bed Swich / Bell 1 No 21
02812 Push.

MAT- h 16A flush type Swich. 1 No 66


02813
MAT- i 16A flush type Socket with shutter. 1 No 66
02814
MAT- j 16A flush type Switch Socket 1 No 99
02815 combined (2 in one).

MAT- k 16A Triangle Plug Top 1 No 50


02816
MAT- l stepped type Electronic Regulator. 1 No 198
02817
MAT- m 3 Plate Jumbo Ceiling Rose. 1 No 21
02818
MAT- n BH / SBH. 1 No 20
02819

18
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- o Pendent Holder / Adopter. 1 No 17


02820
MAT- p Telephone Jack with Connector. 1 No 50
02821
MAT- q TV Antenna Outlet. 1 No 28
02822
MAT- r 15A/10A Flush type Fuse. 1 No 33
02823
MAT- s 32A DP Flush type. 1 No 105
02824
MAT- t Calling Bell. 1 No 72
02825
MAT- u Buzzer. 1 No 61
02826
MAT- v Ding Dong Bell. 1 No 149
02827
MAT- w Electronic Musical Bell. 1 No 242
02828
MAT- x Remote Bell. 1 No 699
02829
MAT- y MC Holder. 1 No 22
02830
MAT- z Spike Guard with 1 No Switch and 4 1 No 385
02831 Nos Sockets.

MAT- A Spike Guard with 4 No Switches and 1 No 550


02832 4 Nos Sockets.

1.8 MODULAR SWITCHES AND


ACCESSORIES
39 ELEC-1.8.1 Supply of …………..
Makes : As per list of recommended brands as category I.

MAT- a 6A / 10A 1 Way 1 Module Modular 1 No 94


02833 Switch.
MAT- b 6A / 10A 2 Way 1 Module Modular 1 No 105
02834 Switch.
MAT- c 6A / 10A 2 Pin 2 Module Modular 1 No 94
02835 Socket.
MAT- d 6A / 10A 3/2 Pin 2 Module Modular 1 No 143
02836 Socket with shutter.
MAT- e 6A / 10A 1 Module Modular Switch 1 No 116
02837 with Neon Indicator.
MAT- f 6A / 10A Modular Bell Push with Neon 1 No 138

19
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

02838 Indicator.

MAT- g 16A / 10A Modular Flush Fuse with 1 No 127


02839 Neon Indicator.
MAT- h 16A / 20A 1 Way 1 Module Modular 1 No 127
02840 Switch.
MAT- i 16A / 20A 2 Way 1 Module Modular 1 No 138
02841 Switch.
MAT- j 20A 1 Way 1 Module Modular Switch 1 No 138
02842 with Indicator.
MAT- k 20A Modular Socket with shutter. 1 No 193
02843
MAT- l 16A/6A 1 way Combi Socket Modular 1 No 198
02844 Socket with shutter
MAT- m 16A Triangle Top. 1 No 160
02845
MAT- n 2 Module Modular type Electronic 1 No 495
02846 step type Fan Regulator.
MAT- o Modular socket type Telephone jack 1 No 99
02847 with Connector
MAT- p Modular co-Axial socket type TV 1 No 99
02848 Antenna outlet.
MAT- q Push type button motor starter for 1 No 798
02849 A.C Units
MAT- r 32A Modular type Double pole Switch 1 No 350
08755 with indicator
MAT- s One Module PVC Blanking plate 1 No 25
08756
MAT- t Skirting Light with LED 230V 3 1 No 175
08757 Module
40 ELEC-1.8.2 Supply of ……………………………………..
Makes : As per list of recommended brands as category II
MAT- a 6A / 10A 1 Way 1 Module Modular 1 No 61
02850 Switch.
MAT- b 6A / 10A 2 Way 1 Module Modular 1 No 72
02851 Switch.
MAT- c 6A / 10A 2 Pin 2 Module Modular 1 No 61
02852 Socket.
MAT- d 6A / 10A 3/2 Pin 2 Module Modular 1 No 94
02853 Socket with shutter.
MAT- e 6A / 10A 1 Module Modular Switch 1 No 77
02854 with Neon Indicator.
MAT- f 6A / 10A Modular Bell Push with Neon 1 No 88
02855 Indicator.

20
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- g 16A / 10A Modular Flush Fuse with 1 No 83


02856 Neon Indicator.
MAT- h 16A / 20A 1 Way 1 Module Modular 1 No 83
02857 Switch.
MAT- i 16A / 20A 2 Way 1 Module Modular 1 No 94
02858 Switch.
MAT- j 20A 1 Way 1 Module Modular Switch 1 No 88
02859 with Indicator.
MAT- k 20A Modular Socket with shutter. 1 No 138
02860
MAT- l 16A/6A 1 way Combi Socket Modular 1 No 138
02861 Socket with shutter
MAT- m 16A Triangle Top. 1 No 66
02862
MAT- n 2 Module Modular type Electronic 1 No 402
02863 step type Fan Regulator.
MAT- o Modular socket type Telephone jack 1 No 66
02864 with Connector
MAT- p Modular co-Axial socket type TV 1 No 66
02865 Antenna outlet.
MAT- q Push type button motor starter for 1 No 743
02866 A.C Units
MAT- r 32A Modular type Double pole Switch 1 No 300
08758 with indicator
MAT- s One Module PVC Blanking plate 1 No 20
08759
MAT- t Skirting Light with LED 230V 3 1 No 150
08760 Module
COVER FRAMES

41 ELEC-1.8.3 Supply of ………….


Makes : As per list of recommended brands as category I.
MAT- a 1 or 2 Modular Cover Frame. 1 No 66
02867
MAT- b 3 Modular Cover Frame. 1 No 77
02868
MAT- c 4 Modular Cover Frame. 1 No 88
02869
MAT- d 6 Modular Cover Frame . 1 No 132
02870
MAT- e 8 Modular Horizontal / Vertical Cover 1 No 171
02871 Frame.
MAT- f 12 Modular Vertical Cover Frame. 1 No 209
02872

21
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
42 ELEC-1.8.4 Supply of ………….
Makes : As per list of recommended brands as category II
MAT- a 1 or 2 Modular Cover Frame. 1 No 55
02873
MAT- b 3 Modular Cover Frame. 1 No 66
02874
MAT- c 4 Modular Cover Frame. 1 No 77
02875
MAT- d 6 Modular Cover Frame . 1 No 110
02876
MAT- e 8 Modular Horizontal / Vertical Cover 1 No 138
02877 Frame.
MAT- f 12 Modular Vertical Cover Frame. 1 No 165
02878
SECTION - 2

2.1 PANEL MOUNTING SWITCH


DISCONNECTOR FUSE UNITS (
SDFU )
43 ELEC-2.1.1 Supply of …………....TPN Switch Disconnector Fuse Unit aCubical type
without fuses as per IS: 13947/IEC 60947-3
Makes : As per list of recommended brands as category I.
MAT- a 32A 1 No 1430
02879

MAT- b 63A 1 No 2442


02880
MAT- c 125A 1 No 5830
02881
MAT- d 200A 1 No 7645
02882
MAT- e 250A 1 No 9130
02883
MAT- f 400A 1 No 14080
02884
MAT- g 630A 1 No 23870
02885
44 ELEC-2.1.2 Supply of ……….. TPN Switch Disconnector Fuse Unit Cubical type
without fuses as per IS: 13947/IEC 60947-3
Makes : As per list of recommended brands as category II
MAT- a 32A 1 No 1210
02886
MAT- b 63A 1 No 1793
02887
MAT- c 125A 1 No 4015

22
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

02888

MAT- d 200A 1 No 6050


02889
MAT- e 250A 1 No 6820
02890
MAT- f 400A 1 No 10450
02891
MAT- g 630A 1 No 17490
02892
2.2 ON LOAD CHANGEOVER
SWITCHES
(OPEN EXECUTION)

45 ELEC-2.2.1 Supply of ……. 4 Pole Change Over Switch on Load with open Execution
as per IS:13947
Makes : As per list of recommended brands as category I.
MAT- a 63A 1 No 4510
02893
MAT- b 125A 1 No 8470
02894
MAT- c 200A 1 No 11330
02895
MAT- d 250A 1 No 16170
02896
MAT- e 400A 1 No 24420
02897
MAT- f 630A 1 No 29150
02898
46 ELEC-2.2.2 Supply of ……... 4 Pole Change Over Switch on Load with open
Execution as per IS:13947
Makes : As per list of recommended brands as category II.
MAT- a 32 A 1 No 1650
02899
MAT- b 63A 1 No 4070
02900
MAT- c 125A 1 No 8030
02901
MAT- d 200A 1 No 10450
02902
MAT- e 250A 1 No 14850
02903
MAT- f 400A 1 No 22880
02904
MAT- g 630A 1 No 26950

23
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

02905

2.3 OFF LOAD CHANGE OVER


SWITCHES IN SS ENCLOUSURE
47 ELEC-2.3.1 Supply of ………... Off load Changeover Switch in sheet steel enclosure
as per IS:13947
Makes : As per list of recommended brands as category I
MAT- a 32A 240V DP 1 No 1375
02906
MAT- b 63A 415V FP 1 No 4730
02907
MAT- c 100A 415V FP 1 No 8305
02908
48 ELEC-2.3.2 Supply of ………. Off load Changeover Switch in sheet steel enclosure as
per IS:13947
Makes : As per list of recommended brands as category II
MAT- a 32A 240V DP 1 No 798
02909
MAT- b 63A 415V FP 1 No 2750
02910

MAT- c 100A 415V FP 1 No 5170


02911
2.4 AUTO TRANSFER SWITCH

49 ELEC-2.4.1 Supply of …… auto transfer switch for instantaneous switching


between sources as per IEC 60947-6-1
Closed transition,(bare unit- without enclosure) with voltage surge
suppressor,communication interface etc complete.,
Makes : As per list of recommended brands.
MAT- a 125A, 415VAC, FP 1 No 38500
02912
MAT- b 160A, 415VAC FP 1 No 40150
02913
MAT- c 200A 415VACFP 1 No 41250
02914
MAT- d 250A, 415VAC FP 1 No 51700
02915
MAT- e 315A, 415VAC FP 1 No 52250
02916
MAT- f 400A, 415VAC FP 1 No 65450
02917
50 ELEC-2.4.2 Supply of ………..auto transfer switch for instantaneous switching
between sources as per IEC 60947-6-1
Closed transition,(bare unit- without enclosure) with voltage surge
suppressor, communication interface etc complete.

24
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Makes : As per list of recommended brands.

MAT- a 630A,415VAC FP 1 No 83050


02918
MAT- b 800A, 415VAC FP 1 No 110000
02919
MAT- c 1000A,415VAC FP 1 No 136400
02920
MAT- d 1250A, 415VAC FP 1 No 169400
02921
MAT- e 1600 A, 415VAC FP 1 No 210100
02922
MAT- f 2000 A, 415VAC FP 1 No 306900
02923
MAT- g 2500 A, 415VAC FP 1 No 338800
02924
MAT- h 3200 A, 415VAC FP 1 No 435600
02925
2.5 REWIRABLE / DOUBLE BREAK
SWITCHES IN SS ENCLOSURE

51 ELEC-2.5.1 Supply of ……... Rewirable Fuse Switch in SS enclosure as per IS:13947


Makes : As per list of recommended brands as category I

MAT- a 32A 240V SPN 1 No 935


02926
MAT- b 32A 415V TPN 1 No 2090
02927
MAT- c 63A 415V TPN 1 No 4290
02928
MAT- d 100A 415V TPN 1 No 7920
02929
52 ELEC-2.5.2 Supply of ………. Double Break Switch in SS enclosure without fuses as
per IS:13947
Makes : As per list of recommended brands as category II
MAT- a 100A 415V TPN 1 No 7125
02930
MAT- b 200A 415V TPN 1 No 10250
02931
53 ELEC-2.5.3 Supply of …….. ….Rewirable Fuse Switch in SS enclosure as per
IS:13947
Makes : As per list of recommended brands as category I

25
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- a 32A 240V SPN 1 No 660


02932
MAT- b 32A 415V TPN 1 No 1012
02933
MAT- c 63A 415V TPN 1 No 2420
02934
MAT- d 100A 415V TPN 1 No 4620
02935
54 ELEC-2.5.4 Supply of ………...Double Break Switch in SS enclosure without fuse as
per IS:13947
Makes : As per list of recommended brands as category II

MAT- a 100A 415V TPN 1 No 4730


02936
MAT- b 200A 415V TPN 1 No 7700
02937
2.6 HRC FUSE LINKS (DIN/BOLTED
TYPE)
55 ELEC-2.6.1 Supply of……HRC Fuse Links as per IS 13703-Part 2/IEC 60269- Part 2
Makes : As per list of recommended brands as category I

MAT- a 6A to 35 A 1 No 55
02938
MAT- b 45A to 63A 1 No 83
02939
MAT- c 100 A to 160 A 1 No 259
02940
MAT- d 250A to 350A 1 No 385
02941
MAT- e 400A 1 No 732
02942
MAT- f 630A 1 No 1463
05457
2.7 PORCELAIN REWIRABLE FUSE
UNITS.
56 ELEC-2.7.1 Supply of …... Porcelain Rewirable Fuse Units.
Makes : As per list of recommended brands.

MAT- a 32A 240V 1 No 110


02943
MAT- b 32A 415V 1 No 165
02944
MAT- c 63A 415V 1 No 275
02945

26
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- d 100A 415V 1 No 572


02946
57 ELEC-2.7.2 Supply of……... Porcelain Rewirable Fuse Units with extension strip.
Makes : As per list of recommended brands.

MAT- a 200A 415V 1 No 935


02947
MAT- b 300A 415V 1 No 1210
02948
2.8 VOLTAGE SURGE PROTECTORS

58 ELEC-2.8.1 Supply of ………... Voltage Surge Protector.


Makes : As per list of recommended brands.

MAT- a 2 Pole 2 Module 40 KA 1.4 KV 1 No 7700


02949
MAT- b 4 Pole 4 Module 40 KA 1.4 KV 1 No 14438
02950
MAT- c 2 Pole 2 Module 15 KA 1.2 KV 1 No 6160
02951
MAT- d 4 Pole 4 Module 15 KA 1.2 KV 1 No 11550
02952
2.9 PANEL MOUNTING MCCBs

59 ELEC-2.9.1 Supply of ………., Adjustable, Confirms to IEC 60947-2 and IS 13947-


Part 1&2 having Breaking Capacity ………. with thermal magnetic
release Panel Mounted.
Makes : As per list of recommended brands as category I
MAT- a 63A / 60A 3 Pole MCCB,16 KA 1 No 7040
02953
MAT- b 63A / 60A 4 Pole MCCB,16 KA 1 No 7590
02954
MAT- c 125A 3 Pole MCCB,25 KA 1 No 8250
02955
MAT- d 125A 4 Pole MCCB,25 KA 1 No 9570
02956
MAT- e 160A 3 Pole MCCB,25 KA 1 No 10450
02957
MAT- f 160A 4 Pole MCCB,25 KA 1 No 13420
02958
MAT- g 250A 3 Pole MCCB,36/35 KA 1 No 17050
02959
MAT- h 250A 4 Pole MCCB,36/35 KA 1 No 22495
02960
MAT- i 400A 3 Pole MCCB,36/35 KA 1 No 22375
02961

27
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- j 400A 4 Pole MCCB,36/35 KA 1 No 28050


02962
MAT- k 630A 3 Pole MCCB,50 KA 1 No 33550
02963
MAT- l 630A 4 Pole MCCB,50 KA 1 No 41250
02964
MAT- m 800A 3 Pole MCCB,50 KA 1 No 61600
02965
MAT- n 800A 4 Pole MCCB,50 KA 1 No 66000
02966
60 ELEC-2.9.2 Supply of ………., Adjustable, Confirms to IEC 60947-2 and IS 13947-
Part 1&2 having Breaking Capacity ………. with thermal magnetic
release Panel Mounted.
Makes : As per list of recommended brands as category II
MAT- a 63A / 60A 3 Pole MCCB,16 KA 1 No 4950
02967
MAT- b 63A / 60A 4 Pole MCCB,16 KA 1 No 6435
02968
MAT- c 125A 3 Pole MCCB,25 KA 1 No 6270
02969
MAT- d 125A 4 Pole MCCB,25 KA 1 No 8195
02970
MAT- e 160A 3 Pole MCCB,25 KA 1 No 8580
02971
MAT- f 160A 4 Pole MCCB,25 KA 1 No 11330
02972
MAT- g 250A 3 Pole MCCB,36/35 KA 1 No 16720
02973
MAT- h 250A 4 Pole MCCB,36/35 KA 1 No 20240
02974
MAT- i 400A 3 Pole MCCB,36/35 KA 1 No 21010
02975
MAT- j 400A 4 Pole MCCB,36/35 KA 1 No 25190
02976
MAT- k 630A 3 Pole MCCB,50 KA 1 No 29700
02977
MAT- l 630A 4 Pole MCCB,50 KA 1 No 35860
02978
MAT- m 800A 3 Pole MCCB,50 KA 1 No 51150
02979
MAT- n 800A 4 Pole MCCB,50 KA 1 No 57200
02980
PANEL MOUNTING ACBs
(Microprocessor Based)

28
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
61 ELEC-2.9.3 Supply of Air Circuit Breaker Confirms to IS 13947-2, IEC 60947-2 and
BS-EN 60947 with Micro processer based having over load, shot circuit
and earth fault Protection with display and 20 faults
History backup.
Makes : As per list of recommended brands as category I
MAT- a 630A 3 Pole, 50kA Electrically fixed 1 No 115500
02981
MAT- b 630A 3 Pole, 50kA Electrically 1 No 150700
02982 drawout

MAT- c 630A 4 Pole, 50kA Electrically fixed 1 No 139700


02983
MAT- d 630A 4 Pole, 50kA Electrically 1 No 187000
02984 drawout
MAT- e 800A 3 Pole, 50kA Electrically 1 No 159500
02985 drawout
MAT- f 800A 4 Pole, 50kA Electrically 1 No 198000
02986 drawout
MAT- g 1000A 3 Pole, 50kA Electrically 1 No 167200
02987 drawout
MAT- h 1000A 4 Pole, 50kA Electrically 1 No 209000
02988 drawout
MAT- i 1250A 3 Pole, 50kA Electrically 1 No 220000
02989 drawout
MAT- j 1250A 4 Pole, 50kA Electrically 1 No 269500
02990 drawout
MAT- k 1600A 3 Pole, 50kA Electrically 1 No 247500
02991 drawout
MAT- l 1600A 4 Pole, 50kA Electrically 1 No 286000
02992 drawout
MAT- m 2000A 3 Pole, 75kA Electrically 1 No 289300
02993 drawout
MAT- n 2000A 4 Pole, 75kA Electrically 1 No 352000
02994 drawout
MAT- o 2500A 3 Pole, 75kA Electrically 1 No 396000
02995 drawout
MAT- p 2500A 4 Pole, 75kA Electrically 1 No 484000
02996 drawout
MAT- q 3200A 3 Pole, 75kA Electrically 1 No 407000
02997 drawout
MAT- r 3200A 4 Pole, 75kA Electrically 1 No 517000
02998 drawout

29
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
62 ELEC-2.9.4 Supply of Air Circuit Breaker Confirms to IS 13947-2, IEC 60947-2 and
BS-EN 60947 with Micro processer based having over load, shot circuit
and earth fault Protection.
Makes : As per list of recommended brands as category II
MAT- a 630A 3 Pole, 50kA Electrically fixed 1 No 101200
02999
MAT- b 630A 3 Pole, 50kA Electrically 1 No 132000
03000 drawout
MAT- c 630A 4 Pole, 50kA Electrically fixed 1 No 115500
03001
MAT- d 630A 4 Pole, 50kA Electrically 1 No 159500
03002 drawout
MAT- e 800A 3 Pole, 50kA Electrically 1 No 137500
03003 drawout
MAT- f 800A 4 Pole, 50kA Electrically 1 No 176000
03004 drawout
MAT- g 1000A 3 Pole, 50kA Electrically 1 No 154000
03005 drawout
MAT- h 1000A 4 Pole, 50kA Electrically 1 No 176000
03006 drawout
AIR INSULATED BUS DUCT

63 ELEC-2.9.5 Supply, instalation, testing and commisioning of ........Amp, ........KA


breaking capacity (100% Neutral busbar) air insulated compact
Raising mains/Bus Duct system made of CRCA sheet/Hot Galvanized
steel encloser of thickness not less than 0.8 mm having degree of
protection of IP 55 as per IEC/EN 61439-6, PVC/Plastic insulated
reinforced with glass fibre four strip ALUMINIUM busbar in convinent
sections including necessary end cover units suitable for 415 volts 3
phase, 4 wire, 50 Hz A.C. System,etc.,with necessary joints Fire barrrier
at each floor Provision of tapping at each floor/every meter,continuous
earthing with 2 nos alluminium strip of suitable size (one on each side0
including GI clamping brackets,angle iron brackets,steel
fastners,connecting to earth system as required .
Makes : As per list of recommended brands.
MAT- a 400Amp, 50 - 53KA RM 9625
03007
MAT- b 630Amp, 50 - 63KA RM 11440
03008
MAT- c 800 Amp, 50 - 76KA RM 12540
03009
MAT- d 1000 Amp, 50 - 76KA RM 14410
03010
MAT- e 1250 Amp, 50 - 76KA RM 15070
03011
MAT- f 1600 Amp, 50 - 76KA RM 18920
03012

30
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
64 MAT- ELEC-2.9.6 Supply and Fixing of Spring Bracket 1 No 5720
03013 with fixing kit for Air Insulated
Busduct / Raising Mains.
Makes : As per list of recommended
brands.
65 ELEC-2.9.7 Supply and Fixing of ……. Amps Horizontal / Vertical bends for Air
Insulated Bus Duct .
Makes : As per list of recommended brands.
MAT- a 400 Amps 1 No 11000
03014
MAT- b 630 Amps 1 No 12540
03015
MAT- c 800 Amps 1 No 13090
03016
MAT- d 1000Amps 1 No 15345
03017
MAT- e 1250 Amps 1 No 16500
03018
MAT- f 1600 Amps 1 No 18700
03019
66 ELEC-2.9.8 Supply and Fixing of …...Amps Tap off box for Air Insulated Busduct.
Makes : As per list of recommended brands.

MAT- a 125A 1 No 13090


03020
MAT- b 250A 1 No 15180
03021
MAT- c 400A 1 No 22440
03022
MAT- d 630 A 1 No 24420
03023
SANDWITCH BUSDUCT

67 ELEC-2.9.9 Supply, instalation, testing and commisioning of .......Amp, ............KA


breaking capacity (100% Neutral busbar) sandwitch Busduct
system made of CRCA sheet/Hot Galvanized steel encloser of thickness
not less than 1.5mm having degree of protection of IP 55/IP 65 as per
IEC/EN 61439-6, PVC/Plastic insulated reinforced with glass fibre four
strip ALUMINIUM busbar in convinent sections including end cover units
suitable for 415 volts 3 phase, 4 wire, 50 Hz A.C. System,etc., with
necessary joints Fire barrrier at each floor Provision of tapping at each
floor/every meter,continuous earthing with 2 nos alluminium strip of
suitable size (one on each side0 including GI clamping brackets,angle
iron brackets,steel fastners,connecting to earth system as required .
Makes : As per list of recommended brands.
MAT- a 630Amp, 36/40 RM 11770
03024
MAT- b 800Amp, 42/50KA RM 13200

31
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03025

MAT- c 1000Amp, 50KA RM 14520


03026
MAT- d 1250 Amp,75kA RM 15180
03027
MAT- e 1600 Amp,80 kA RM 19030
03028
MAT- f 2000 Amp ,80kA RM 23320
03029
MAT- g 2500 Amp ,150 kA RM 33440
03030
MAT- h 3200 Amp,160kA RM 38720
03031
MAT- i 4000 Amp,160kA RM 51810
03032
68 ELEC-2.9.10 Supply and Fixing of …….Amps Horizontal / Vertical bends for sandwitch
Bus Duct .
Makes : As per list of recommended brands.
MAT- a 630A 1 No 11990
03033
MAT- b 800A 1 No 12980
03034
MAT- c 1000A 1 No 13530
03035
MAT- d 1250 A 1 No 14630
03036
MAT- e 1600 A 1 No 16720
03037
MAT- f 2000 A 1 No 19470
03038
MAT- g 2500 A 1 No 24530
03039
MAT- h 3200 A 1 No 29810
03040
MAT- i 4000 A 1 No 33440
03041
69 ELEC-2.9.11 Supply and Fixing of …….. Amps Copper Flexibles for three phases and
neutral for Air Insulated / sandwitchBusduct .
Makes : As per list of recommended brands.
MAT- a 400A 1 No 25630
03042
MAT- b 630A 1 No 27170
03043

32
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 800A 1 No 29590


03044
MAT- d 1000A 1 No 31130
03045
MAT- e 1250 A 1 No 33000
03046
MAT- f 1600 A 1 No 35530
03047
MAT- g 2000 A 1 No 38720
03048
MAT- h 2500 A 1 No 44000
03049
MAT- i 3200 A 1 No 47080
03050
MAT- j 4000 A 1 No 50270
03051
69 ELEC-2.9.12 Supply and fixing of Flange end for ……….Amps for Air insulated
Busdusts .
Makes : As per list of recommended brands.
MAT- a 400A 1 No 9900
03052
MAT- b 630A 1 No 13530
03053
MAT- c 800A 1 No 16720
03054
70 ELEC-2.9.13 Supply and fixing of Flange end for ……….Amps for Sandwitch
Busdusts
Makes : As per list of recommended brands.
MAT- a 400A 1 No 11990
03055
MAT- b 630A 1 No 17160
03056
MAT- c 800A 1 No 19910
03057
MAT- d 1000 A 1 No 21010
03058
MAT- e 1250 A 1 No 14520
03059
MAT- f 1600 A 1 No 16390
03060
MAT- g 2000 A 1 No 25520
03061
MAT- h 2500 A 1 No 43230
03062

33
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- i 3200 A 1 No 47300


03063
MAT- j 4000 A 1 No 49720
03064
71 ELEC-2.9.14 Supply and Fixing of …...Amps Tap off box for Sandwitch Busduct.
Makes : As per list of recommended brands.

MAT- a 160A 1 No 16500


03065
MAT- b 250A 1 No 27720
03066
MAT- c 400A 1 No 35090
03067
MAT- d 630A 1 No 50930
03068
MAT- e 800A 1 No 76450
03069

2.10 MCBs (AS PER IS:60898-1:2002)

72 ELEC-2.10.1 Supply of ,……... 10KA C/D Curve ISI Mark.


Makes : As per list of recommended brands as category I
MAT- a 6-32A SP MCB 1 No 209
03070
MAT- b 40-63A SP MCB 1 No 440
03071
MAT- c 6-32A DP MCB 1 No 633
03072
MAT- d 40-63A DP MCB 1 No 1007
03073
MAT- e 6-32A TP MCB 1 No 1007
03074
MAT- f 40-63A TP MCB 1 No 1617
03075
MAT- g 6-32A FP MCB 1 No 1386
03076
MAT- h 40-63A FP MCB 1 No 2019
03077
73 ELEC-2.10.2 Supply of ,……... 10KA C/D Curve ISI Mark.
Makes : As per list of recommended brands as category II
MAT- a 6-32A SP MCB 1 No 176
03078

34
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b 40-63A SP MCB 1 No 380


03079
MAT- c 6-32A DP MCB 1 No 534
03080
MAT- d 40-63A DP MCB 1 No 770
03081
MAT- e 6-32A TP MCB 1 No 831
03082
MAT- f 40-63A TP MCB 1 No 1254
03083
MAT- g 6-32A FP MCB 1 No 1133
03084
MAT- h 40-63A FP MCB 1 No 1573
03085
74 ELEC-2.10.3 Supply of 6-32A 10KA SP MCB, C/D Curve ISI Mark.
Makes : As per list of recommended brands as category III
MAT- a 6-32A SP MCB 1 No 143
03086
MAT- b 40-63A SP MCB 1 No 242
03087
MAT- c 6-32A DP MCB 1 No 374
03088
MAT- d 40-63A DP MCB 1 No 550
03089
MAT- e 6-32A TP MCB 1 No 671
03090
MAT- f 40-63A TP MCB 1 No 1045
03091
MAT- g 6-32A FP MCB 1 No 880
03092
MAT- h 40-63A FP MCB 1 No 1122
03093
2.11 ISOLATORS CONFIRMS TO I E C
60947 PART-III
75 ELEC-2.11.1 Supply of ……... Isolator.
Makes : As per list of recommended brands as category I.
MAT- a 32A DP 1 No 358
03094
MAT- b 40A DP 1 No 396
03095
MAT- c 63A DP 1 No 523
03096
MAT- d 40A TP 1 No 671

35
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03097

MAT- e 63A TP 1 No 792


03098
MAT- f 40A FP 1 No 880
03099
MAT- g 63A FP 1 No 990
03100
MAT- h 100A FP 1 No 1045
03101
76 ELEC-2.11.2 Supply of ……. Isolator.
Makes : As per list of recommended brands as category II
MAT- a 32A DP 1 No 347
03102
MAT- b 40A DP 1 No 363
03103
MAT- c 63A DP 1 No 440
03104
MAT- d 40A TP 1 No 627
03105
MAT- e 63A TP 1 No 638
03106
MAT- f 40A FP 1 No 726
03107
MAT- g 63A FP 1 No 781
03108
MAT- h 100A FP 1 No 963
03109
77 ELEC-2.11.3 Supply of…….. Isolator.
Makes : As per list of recommended brands as category III
MAT- a 32A DP 1 No 231
03110
MAT- b 40A DP 1 No 275
03111
MAT- c 63A DP 1 No 374
03112
MAT- d 40A TP 1 No 402
03113
MAT- e 63A TP 1 No 462
03114
MAT- f 40A FP 1 No 622
03115
2.12 RCCBs(ELCB/RCD) CONFIRMS TO
IEC:61008 AND IS:12640-1

36
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
78 ELEC-2.12.1 Supply of ……….. RCCB for earth leakage protection.
Makes : As per list of recommended brands as category I.
MAT- a 40A 2 Pole,30mA 1 No 2937
03116
MAT- b 40A 2 Pole,100mA 1 No 3113
03117
MAT- c 40A 4 Pole30mA 1 No 3234
03118
MAT- d 40A 4 Pole ,100mA 1 No 3355
03119
MAT- e 63A 2 Pole,30mA, 1 No 3630
03120
MAT- f 63A 2 Pole,100mA 1 No 3575
03121
MAT- g 63A 4 Pole,30mA 1 No 3740
03122
MAT- h 63A 4 Pole,100mA 1 No 4158
03123
79 ELEC-2.12.2 Supply of ……….. RCCB for earth leakage protection.
Makes : As per list of recommended brands as category II

MAT- a 40A 2 Pole,30mA 1 No 2475


03124
MAT- b 40A 2 Pole,100mA 1 No 2530
03125
MAT- c 40A 4 Pole30mA 1 No 2750
03126
MAT- d 40A 4 Pole ,100mA 1 No 2860
03127
MAT- e 63A 2 Pole,30mA, 1 No 3091
03128

MAT- f 63A 2 Pole,100mA 1 No 3168


03129
MAT- g 63A 4 Pole,30mA 1 No 3289
03130
MAT- h 63A 4 Pole,100mA 1 No 3300
03131
RCBO CONFIRMS TO IEC:61009-1

80 ELEC-2.12.3 Supply of ……………………RCBO for over load, short-circuit and earth


leakage protection.
Makes : As per list of recommended brands.

37
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- a 40A 2 Pole,30mA 1 No 5005


03132
MAT- b 40A 2 Pole,100mA 1 No 5467
03133
MAT- c 40A 4 Pole30mA 1 No 5687
03134
MAT- d 40A 4 Pole ,100mA 1 No 6017
03135
MAT- e 63A 2 Pole,30mA, 1 No 5984
03136
MAT- f 63A 2 Pole,100mA 1 No 6336
03137
MAT- g 63A 4 Pole,30mA 1 No 6710
03138
MAT- h 63A 4 Pole,100mA 1 No 6842
03139
MAT- i Supply of MCB type Changeover switch 20A Double 1980
08761 Pole 2 Way 400V AC suitable to fix on Din Channel

2.13 MCB DISTRIBUTION BOARDS


(AS PER IS 8623; IS 13032; IEC
61439-3)
SPN DBs

81 ELEC-2.13.1 Supply of ………….Protection suitable for …………. S.P out goings and
for 1 No Incommer etc complete as per IS 8623; IS 13032; IEC 61439-3.
Makes : As per list of recommended brands as category I.
MAT- a 4 Way SPN DB with IP 30 , 1 No 963
03140 4Nos
MAT- b 8 Way SPN DB with IP 30, 8 1 No 1045
03141 Nos
MAT- c 12 Way SPN DB with IP 30, 12 1 No 1265
03142 Nos
MAT- d 4 Way SPN DB with IP 43, 4 1 No 1320
03143 Nos
MAT- e 8 Way SPN DB with IP 43, 8 1 No 1430
03144 Nos
MAT- f 12 Way SPN DB with IP 43, 12 1 No 1733
03145 Nos
82 ELEC-2.13.2 Supply of ………….Protection suitable for …………. S.P out goings and
for 1 No Incommer etc complete as per IS 8623; IS 13032; IEC 61439-3.
Makes : As per list of recommended brands as category II.
MAT- a 4 Way SPN DB with IP 30 , 1 No 825
03146 4Nos
MAT- b 8 Way SPN DB with IP 30, 8 1 No 880

38
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03147 Nos

MAT- c 12 Way SPN DB with IP 30, 12 1 No 1100


03148 Nos
MAT- d 4 Way SPN DB with IP 43, 4 1 No 1155
03149 Nos
MAT- e 8 Way SPN DB with IP 43, 8 1 No 1265
03150 Nos
MAT- f 12 Way SPN DB with IP 43, 12 1 No 1485
03151 Nos
83 ELEC-2.13.3 Supply of ………….Protection suitable for …………. S.P out goings and
for 1 No Incommer etc complete as per IS 8623; IS 13032; IEC 61439-3.
Makes : As per list of recommended brands as category III .
MAT- a 4 Way SPN DB with IP 30 , 1 No 715
03152 4Nos
MAT- b 8 Way SPN DB with IP 30, 8 1 No 770
03153 Nos
MAT- c 12 Way SPN DB with IP 30, 12 1 No 963
03154 Nos
MAT- d 4 Way SPN DB with IP 43, 4 1 No 1034
03155 Nos
MAT- e 8 Way SPN DB with IP 43, 8 1 No 1100
03156 Nos
MAT- f 12 Way SPN DB with IP 43, 12 1 No 1320
03157 Nos
TPN DBs

84 ELEC-2.13.4 Supply of ………………... Protection suitable for ………..S.P. out goings


and for 1 No 4 pole Incommer etc complete as per IS 8623; IS 13032;
IEC 61439-3.
Makes : As per list of recommended brands as category I.
MAT- a (8 +12) 4 Way TPN DB Horizontal 1 No 1870
03158 with IP 30, 12 Nos
MAT- b (8 +18) 6 Way TPN DB Horizontal 1 No 2640
03159 with IP 30, 18 Nos
MAT- c (8 +12) 4 Way TPN DB Horizontal 1 No 2970
03160 with IP 43, 12 Nos
MAT- d (8 +18) 6 Way TPN DB Horizontal 1 No 4180
03161 with IP 43, 18 Nos
MAT- e (8 +24) 8 Way TPN DB Horizontal 1 No 4730
03162 with IP 43, 24 Nos
85 ELEC-2.13.5 Supply of ………………... Protection suitable for ………..S.P. out goings
and for 1 No 4 pole Incommer etc complete as per IS 8623; IS 13032;
IEC 61439-3.
Makes : As per list of recommended brands as category II.
MAT- a (8 +12) 4 Way TPN DB Horizontal 1 No 1705

39
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03163 with IP 30, 12 Nos

MAT- b (8 +18) 6 Way TPN DB Horizontal 1 No 2365


03164 with IP 30, 18 Nos
MAT- c (8 +12) 4 Way TPN DB Horizontal 1 No 2640
03165 with IP 43, 12 Nos
MAT- d (8 +18) 6 Way TPN DB Horizontal 1 No 3630
03166 with IP 43, 18 Nos
MAT- e (8 +24) 8 Way TPN DB Horizontal 1 No 4180
03167 with IP 43, 24 Nos
86 ELEC-2.13.6 Supply of ………………... Protection suitable for ……. S.P. out goings
and for 1 No 4 pole Incommer etc complete as per IS 8623; IS 13032;
IEC 61439-3.
Makes : As per list of recommended brands as category III.
MAT- a (8 +12) 4 Way TPN DB Horizontal 1 No 1540
03168 with IP 30, 12 Nos
MAT- b (8 +18) 6 Way TPN DB Horizontal 1 No 2090
03169 with IP 30, 18 Nos
MAT- c (8 +12) 4 Way TPN DB Horizontal 1 No 2035
03170 with IP 43, 12 Nos
MAT- d (8 +18) 6 Way TPN DB Horizontal 1 No 2640
03171 with IP 43, 18 Nos

MAT- e (8 +24) 8 Way TPN DB Horizontal 1 No 3080


03172 with IP 43, 24 Nos
VTPN DBs

87 ELEC-2.13.7 Supply of ………... Protection suitable for TP/SP out goings and for 1 No
4 pole Incommer etc complete as per IS 8623; IS 13032; IEC 61439-3.
Makes : As per list of recommended brands as category I .

MAT- a 4 Way VTPN DB with IP 43 1 No 7623


03173
MAT- b 6 Way VTPN DB with IP 43 1 No 8833
03174
MAT- c 8 Way VTPN DB with IP 43 1 No 9801
03175
88 ELEC-2.13.8 Supply of 7 Segment DB with IP 42 Protection with provision for FPMCB
/ Isolator / RCCB / RCBO as incomer, 3Nos DPMCB / Isolator / RCCB /
RCBO as sub incomer and ……….Nos SPMCB's as out going as per IS
8623; IS 13032; IEC 61439-3.
Makes : As per list of recommended brands as category I
MAT- a 4 Way TPN DB, 12 Nos 1 No 7865
03176
MAT- b 8 Way TPN DB, 24 Nos 1 No 8965
03177

40
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
89 ELEC-2.13.9 Supply of ……..suitable for accomodating 125A / 160A 4 Pole MCCB as
incomer and TP/SP MCBs as outgoing etc., as per IS 8623; IS 13032;
IEC 61439-3.
Makes : As per list of recommended brands as category I.
MAT- a 4 Way VTPN DB with IP 43 1 No 9922
03178 Protection.
MAT- b 8 Way VTPN DB with IP 43 1 No 12463
03179 Protection.
90 ELEC-2.13.10 Supply of ………... Protection suitable for TP/SP out goings and for 1 No
4 pole Incommer etc complete as per IS 8623; IS 13032; IEC 61439-3. .
Makes : As per list of recommended brands as category II.
MAT- a 4 Way VTPN DB with IP 43 1 No 6710
03180
MAT- b 6 Way VTPN DB with IP 43 1 No 7150
03181
MAT- c 8 Way VTPN DB with IP 43 1 No 8360
03182
91 ELEC-2.13.11 Supply of 7 Segment with IP 42 Protection with provision for FPMCB /
Isolator / RCCB / RCBO as incomer, 3Nos DPMCB / Isolator / RCCB /
RCBO as sub incomer and ……….Nos SPMCB's as out going. etc.,as
per IS 8623; IS 13032; IEC 61439-3.
Makes : As per list of recommended brands as category II.
MAT- a 4 Way TPN DB,12 Nos 1 No 7040
03183
MAT- b 8 Way TPN DB,24 Nos 1 No 8030
03184
92 ELEC-2.13.12 Supply of ……..suitable for accomodating 125A / 160A 4 Pole MCCB as
incomer and TP/SP MCBs as outgoing etc., as per IS 8623; IS 13032;
IEC 61439-3.
Makes : As per list of recommended brands as category II.
MAT- a 4 Way VTPN DB with IP 43 1 No 8030
03185 Protection.
MAT- b 8 Way VTPN DB with IP 43 1 No 10120
03186 Protection.
93 ELEC-2.13.13 Supply of ………. Plug and Socket in SS enclosure.
Makes : As per list of recommended brands as category I.
MAT- a 20A SP 1 No 1084
03187
MAT- b 20A TP 1 No 2052
03188
MAT- c 32A TP 1 No 2420
03189
94 ELEC-2.13.14 Supply of ……….. Plug and Socket in SS enclosureas per IS 8623; IS
13032; IEC 61439-3.
Makes : As per list of recommended brands as category II.
MAT- a 20A SP 1 No 770

41
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03190

MAT- b 20A TP 1 No 1375


03191
MAT- c 32A TP 1 No 1815
03192
95 ELEC-2.13.15 Supply of 20A SP Plug and Socket in SS enclosure etc., as per IS 8623;
IS 13032; IEC 61439-3. .
Makes : As per list of recommended brands as category III.

MAT- a 20A SP 1 No 578


03193
MAT- b 20A TP 1 No 1100
03194
MAT- c 32A TP 1 No 1540
03195
96 ELEC-2.13.16 Supply of …. Enclosure with IP 20 Protection etc., complete as per IS
8623; IS 13032; IEC 61439-3.
Makes : As per list of recommended brands as category I.
MAT- a SP 1 No 330
03196
MAT- b DP/TP/FP 1 No 440
03197
97 ELEC-2.13.17 Supply of …. Enclosure with IP 20 Protection etc complete as per IS
8623; IS 13032; IEC 61439-3.
Makes : As per list of recommended brands as category II.

MAT- a SP 1 No 253
03198
MAT- b DP/TP/FP 1 No 363
03199
98 ELEC-2.13.18 Supply of …. Enclosure with IP 20 Protection.
Makes : As per list of recommended brands as category III.

MAT- a SP 1 No 231
03200
MAT- b DP/TP/FP 1 No 341
03201
SECTION - 3

3.1 STREET LIGHT LUMINAIRES

99 MAT- ELEC-3.1.1 Supply of fluorescent street light luminaire with sheet alluminium housing
03202 and UV stabilised acrylic cover with Electronic ballast and all standard
accessories etc.
Makes : As per list of recommended brands as category I.
1 x 36/40 W 1 No 1265

42
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
100 MAT- ELEC-3.1.2 Supply of fluorescent street light luminaire with sheet alluminium housing
03203 and UV stabilised acrylic cover with Electronic ballast and all standard
accessories etc.
Makes : As per list of recommended brands as category II.
1 x 36/40 W 1 No 880

101 ELEC-3.1.3 Supply of ……….. Street light luminaire integral with pressure diecast
alluminium housing having pot optics with IP66 protection with all
standard accessories etc.
Makes : As per list of recommended brands as category I.
MAT- a 70W SV / MH 1 No 2860
03204
MAT- b 150W SV / MH 1 No 4180
03205
MAT- c 250W SV / MH 1 No 4620
03206
102 ELEC-3.1.4 Supply of ………..Street light luminaire integral with pressure diecast
alluminium housing having pot optics with IP66 protection with all
standard accessories etc.
Makes : As per list of recommended brands as category II.
MAT- a 70W SV / MH 1 No 2420
03207
MAT- b 150W SV / MH 1 No 3520
03208
MAT- c 250W SV / MH 1 No 4070
03209
103 ELEC-3.1.5 Supply of ……... Flood light luminaire with Non - integral weather proof
diecast alluminium housing with IP65 / IP66 protection with Control Gear
Box without lamp.
Makes : As per list of recommended brands as category I.
MAT- a 1 x 400W MH 1 No 5940
03210
104 ELEC-3.1.6 Supply of ……... Flood light luminaire with Non - integral weather proof
diecast alluminium housing with IP65 / IP66 protection with Control Gear
Box without lamp.
Makes : As per list of recommended brands as category II.
MAT- a 1 x 400W MH 1 No 4950
03212
105 ELEC-3.1.7 Supply of …….. Hallozen Flood light luminaire with cast alluminium
housing and tough end glass cover with all standard accessories.
Makes : As per list of recommended brands.

MAT- a 500W 1 No 495


03214
MAT- b 1000W 1 No 935
03215
3.2 LED POST TOP LANTERN

43
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

LUMINAIRES

107 MAT- ELEC-3.2.1 Supply and Transportation of 40W 1 No 7820


03218 LED Post top lantern made with cast
Alluminium with decorative opel
polycarbonate diffuser with IP 65
protection etc., complete with all
accessories
Makes : As per list of recommended
brands.
108 MAT- ELEC-3.2.2 Supply and Transportation of 25 W 1 No 17480
03219 Post Top lantern made with high
Pressure die cast alluminium bodywith
polycarbonate / high impact Poly
carbonate protector for optimal
luminous flux ,IP66 suitable for
vertical mounting of 76 mm dia.the
luminaire shall have CCT 3000-4000K
with internal surge protection of 4KV
and External Surge Protection of 10
KV ,Pf>0.95 etc.,
Makes : As per list of recommended
brands.
109 MAT- ELEC-3.2.3 Supply and Transportation of 35/40 W 1 No 21620
03220 Post Top lantern made with high
Pressure die cast alluminium bodywith
polycarbonate / high impact PMMA
protector for optimal luminous flux
,IP66 suitable for vertical mounting of
76 mm dia.the luminaire shall have
CCT 3000-4000K with internal surge
protection of 4KV and External Surge
Protection of 10 KV ,Pf>0.95 etc.,
complete
Makes : As per list of recommended
brands.
MAT- ELEC-3.2.4 Supply and Transportation of 20 W 1 No 4200
08762 LED Post top lantern made with cast
Alluminium with decorative opel
polycarbonate diffuser with IP 65
protection etc., complete with all
accessories
Makes : As per list of recommended
brands.
3.3 ACCESSORIES FOR MV / SV / MH
LUMINAIRES
COPPER BALLASTS

110 ELEC-3.3.1 Supply of copper ballast.


Makes : As per list of recommended brands.
MAT- a 70 W SV / MH 1 No 660
03221
MAT- b 150 W SV / MH 1 No 935
03222

44
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 250 W SV / MH 1 No 1430


03223
MAT- d 400 W SV / MH 1 No 2090
03224
111 ELEC-3.3.2 Supply of 70 W SV / MH copper ballast.
Makes : As per list of recommended brands.

MAT- a 70 W SV / MH 1 No 523
03225
MAT- b 150 W SV / MH 1 No 759
03226
MAT- c 250 W SV / MH 1 No 1100
03227
MAT- d 400 W SV / MH 1 No 1430
03228
IGNITOR

112 MAT- ELEC-3.3.3 Supply of Ignitor for SV / MH Lamp. 1 No 165


03229 Makes : As per list of recommended
brands.

HPF CAPACITORS

113 ELEC-3.3.4 Supply of ….. HPF Capacitor.


Makes : As per list of recommended brands.
MAT- a 4 mfd 1 No 99
03230
MAT- b 10 mfd 1 No 165
03231
MAT- c 15 mfd 1 No 193
03232
MAT- d 20 mfd 1 No 264
03233
MAT- e 33 mfd 1 No 385
03234
MAT- f 42 mfd 1 No 440
03235
3.4 LAMPS

114 ELEC-3.4.1 Supply of …….. Lamp with ISI mark.


Makes : As per list of recommended brands as category I.
MAT- a 500W Hallozen 1 No 99
03236
MAT- b 1000W Hallozen 1 No 121
03237
MAT- c 70W SV 1 No 440

45
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03238

MAT- d 150W SV 1 No 660


03239
MAT- e 250W SV 1 No 743
03240
MAT- f 70W MH 1 No 825
03241
MAT- g 150W MH 1 No 880
03242
MAT- h 250W MH 1 No 1210
03243
MAT- i 400W MH 1 No 1430
03244
115 ELEC-3.4.2 Supply of ……….. Lamp with ISI mark.
Makes : As per list of recommended brands as category II.

MAT- a 500W Hallozen 1 No 66


03245
MAT- b 1000W Hallozen 1 No 99
03246
MAT- c 70W SV 1 No 352
03247
MAT- d 150W SV 1 No 633
03248
MAT- e 250W SV 1 No 688
03249
MAT- f 70W MH 1 No 798
03250
MAT- g 150W MH 1 No 853
03251
MAT- h 250W MH 1 No 1089
03252
MAT- i 400W MH 1 No 1265
03253
3.5 AUTOMATIC STREET LIGHT
CONTROL SYSTEMS
116 ELEC-3.5.1 Supply of Automatic Street Light Control System with Optical Micro
Sensor, Low volatage / High voltage trip and reset, operating voltage 150
- 280V AC, 50 HZ with suitable SMC enclousure of IP 54 protection,
MCBs and contactor suitable to control the load of ...... of single phase
load with necessary clamping arrangements.
Makes : As per list of recommended brands.
MAT- a 1 KW 1 No 9900
03254

46
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b 3 KW 1 No 12430
03255
MAT- c 5 KW 1 No 12980
03256
MAT- d 8 KW 1 No 14850
03257
117 ELEC-3.5.2 Supply of Automatic Street Light Control System with Optical Micro
Sensor, Low volatage / High voltage trip and reset, operating voltage 150
- 280V AC per Phase, 50 HZ with suitable SMC enclousure of IP 54
protection, MCBs and contactor suitable to control the load of ....... of
Three phase load with necessary clamping arrangements.
Makes : As per list of recommended brands.
MAT- a 5 KW 1 No 16280
03258
MAT- b 8 KW 1 No 16830
03259
MAT- c 12 KW 1 No 20350
03260
MAT- d 25KW 1 No 32340
03261
MAT- e 50KW 1 No 46200
03262
ELEC-3.5.3 Supply and fixing of Automatic Street Light
Controller with optical micro scanner low
voltage/ High Voltage trip and reset operating
voltage 150 - 280V AC, withstands up to 440V ,
50 HZ with suitable ABS enclosure of IP 54
protection, suitable to control the load of 10A of
single phase with necessary arrangements etc
complete
Makes : As per list of recommended brands.
MAT- a SLASM-01-10A /equivalent (Dusk to 1 No 3500
08763 Dawn)
MAT- b SLASM-02-10A /equivalent ( Time 1 No 4500
08764 setting after 4hr
MAT- c SLASM-03-10A /equivalent ( Time 1 No 4200
08765 setting 4hr,6Hr, 8Hr)
3.6 INTERNAL LUMINAIRES

118 ELEC-3.6.1 Supply of ……. Box type tube light luminaire powder coated CRCA sheet
steel housing with Electronic Ballast Chokes and all standard
accessories.
Makes : As per list of recommended brands as category I.
MAT- a 1 x 36/40W 1 No 792
03263
MAT- b 2 x 36/40W 1 No 1100
03264

47
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
119 ELEC-3.6.2 Supply of ……... Box type tube light 1 No
luminaire powder coated CRCA sheet
steel housing with Electronic Ballast
Chokes and all standard accessories.
Makes : As per list of recommended
brands as category II.
MAT- a 1 x 36/40W 1 No 715
03265
MAT- b 2 x 36/40W 1 No 1045
03266
120 MAT- ELEC-3.6.3 Supply of 1 x 36/40W Patty type tube 1 No 248
03267 light luminaire powder coated CRCA
sheet steel housing with Copper
Chokes and all standard accessories.
Makes : As per list of recommended
brands.
ACCESSORIES

121 MAT- ELEC-3.6.4 Supply of 9/13W VPIT Ballast for CFL 1 No 116
03268 with ISI mark.
Makes : As per list of recommended
brands.
122 MAT- ELEC-3.6.5 Supply of 18W VPIT Ballast for CFL 1 No 121
03269 with ISI mark.
Makes : As per list of recommended
brands.
123 MAT- ELEC-3.6.6 Supply of 20W Copper Wound Ballast 1 No 121
03270 Makes : As per list of recommended
brands.
124 MAT- ELEC-3.6.7 Supply of 40W Copper Wound 1 No 149
03271 Ballast.
Makes : As per list of recommended
brands.
125 MAT- ELEC-3.6.8 Supply of 36/40W VPIT Ballast. 1 No 165
03272 Makes : As per list of recommended
brands.
126 MAT- ELEC-3.6.9 Supply of 40W Starter. 1 No 9
03273 Makes : As per list of recommended
brands.
127 MAT- ELEC-3.6.10 Supply of Rotor holder(FTL). 1 No 17
03274 Makes : As per list of recommended
brands.

128 MAT- ELEC-3.6.11 Supply of FTL Starter holder. 1 No 17


03275 Makes : As per list of recommended
brands
3.7 FLOURSCENT TUBES / CFL
LAMPS / LED BULBS
129 MAT- ELEC-3.7.1 Supply of 40W-60W Lamp. 1 No 13
03276 Makes : As per list of recommended

48
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

brands.

130 MAT- ELEC-3.7.2 Supply of 18/20W fluorescent tube. 1 No 44


03277 Makes : As per list of recommended
brands.
131 MAT- ELEC-3.7.3 Supply of 36/40W fluorescent tube. 1 No 44
03278 Makes : As per list of recommended
brands.
132 ELEC-3.7.4 Supply of ….. Pin type CFL Lamp.
Makes : As per list of recommended brands.
MAT- a 9W 1 No 66
03279
MAT- b 11W 1 No 77
03280
MAT- c 13W 1 No 99
03281
MAT- d 18W 1 No 105
03282
MAT- e 36W 1 No 138
03283
LED BULBS

133 ELEC-3.7.5 Supply of ………. Lamp with input voltage 90 to 300V, Colour
temparature 3000k - 6500k, Beam angle 170 - 220 degrees, B22 base, .
Makes : As per list of recommended brands.

MAT- a 0.5W LED 1 No 46


03284
MAT- b 3.0W LED 1 No 101
03285
MAT- c 5.0W LED 1 No 110
03286
MAT- d 7.0W LED 1 No 129
03287
135 MAT- ELEC-3.7.6 Supply of 3W to 5W 3000K, AC 160- 1 No 184
03292 260V, LED Candel Lamp for
shandliers.
Makes : As per list of recommended
brands.
136 MAT- ELEC-3.7.7 Supply of 9W/10W LED Mirror Light 1 No 550
08797 fitting with decorative grey end caps,
polycarbonate body and opal acrylic
diffuser etc.
Makes : As per list of recommended
brands.
3.8 LED LUMINAIRES INDOOR

DOWN LIGHTERS

49
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
137 ELEC-3.8.1 Supply and fixing of........ heavy duty LED Down lighter, suitable for
Recessed mounting made of pressure diecast alluminium body with
powder coating, acrylic diffuser with Driver as per IS: 15885 (Part 2/ Sec
13) : 2012 , operating voltaGE-Venture ranGE-Venture of 150 to 265
Volts AC, P.F > 0.9, SurGE-Venture protection: 2KV, THD<10% with high
power LED's having efficacy of > 100 lumins / watt, CCT: 3000K - 5700K,
minimum CRI > 70, Luminaire performance complies to IS 10322 (Part 5 /
Sec-3) etc., complete
Makes : As per list of recommended brands as category I.
MAT- a 6W 1 No 690
03294
MAT- b 9W 1 No 874
03295
MAT- c 12W 1 No 1265
03296
MAT- d 15W 1 No 1357
03297
MAT- e 18W 1 No 1449
03298
138 ELEC-3.8.2 Supply and fixing of ........ heavy duty LED Down lighter, suitable for
Recessed / Surface mounting made of pressure diecast alluminium
body with powder coating, acrylic diffuser with Driver as per IS: 15885
(Part 2/ Sec 13) : 2012 , operating voltage range of 150 to 265 Volts AC,
P.F > 0.9, Surge protection: 2KV, THD<10% with high power LED's
having efficacy of > 90 lumins / watt, CCT: 3000K - 5700K, minimum CRI
> 70, Luminaire performance complies to IS 10322 (Part 5 / Sec-3) etc.,
complete
Makes : As per list of recommended brands as category II.
MAT- a 6W 1 No 644
03299
MAT- b 9W 1 No 819
03300
MAT- c 12W 1 No 1187
03301
MAT- d 15W 1 No 1274
03302
MAT- e 18W 1 No 1362
03303
139 ELEC-3.8.3 Supply and fixing of........ heavy duty LED Down
lighter, suitable for Recessed / Surface mounting
made of pressure diecast alluminium body with
powder coating, acrylic diffuser with Driver as per IS:
15885 (Part 2/ Sec 13) : 2012 , operating voltage
range of 150 to 265 Volts AC, P.F > 0.9, Surge
protection: 2KV, THD<10% with high power LED's
having efficacy of > 80 lumins / watt, CCT: 3000K -
5700K, minimum CRI > 70, Luminaire performance
complies to IS 10322 (Part 5 / Sec-3) etc., complete
Makes : As per list of recommended brands as

50
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

category III.

MAT- a 6W 1 No 561
03304
MAT- b 9W 1 No 722
03305
MAT- c 12W 1 No 1021
03306
MAT- d 15W 1 No 1099
03307
MAT- e 18W 1 No 1182
03308
LED PANEL LIGHTS

140 ELEC-3.8.4 Supply and fixing of........ LED Slim Panel Round
/Square suitable for Recessed / Surface mounting
made of diecast alluminium body with powder coating,
acrylic diffuser with Driver as per IS: 15885 (Part 2/
Sec 13) : 2012 , operating voltaGE-Venture ranGE-
Venture of 150 to 265 Volts AC, P.F > 0.9, SurGE-
Venture protection: 2KV,THD<10%, with high power
LED's having efficacy of > 100 lumins/watt,CCT:
3000K - 5700K, minimum CRI>70, .etc., complete.
Makes : As per list of recommended brands as
category I.
MAT- a 3W 1 No 267
03309
MAT- b 6W 1 No 460
03310
MAT- c 12W 1 No 764
03311
MAT- d 15W 1 No 966
03312
MAT- e 18W 1 No 1058
03313
MAT- f 24W 1 No 1334
03314
MAT- g 36W/40W (600mm x 600mm) square 1 No 3266
03315 type

51
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
141 ELEC-3.8.5 Supply and fixing of ........ LED Slim Panel Round / Square suitable for
Recessed / Surface mounting made of diecast alluminium body with
powder coating, acrylic diffuser with Driver as per IS: 15885 (Part 2/ Sec
13) : 2012 , operating voltage range of 150 to 265 Volts AC, P.F > 0.9,
Surge protection: 2KV,THD<10%, with high power LED's having efficacy
of > 90 lumins/watt,CCT: 3000K - 5700K, minimum CRI>70, .etc.,
complete
Makes : As per list of recommended brands as category II.
MAT- a 3W 1 No 258
03316
MAT- b 6W 1 No 451
03317
MAT- c 12W 1 No 736
03318
MAT- d 15W 1 No 943
03319
MAT- e 18W 1 No 1012
03320
MAT- f 24W 1 No 1242
03321
MAT- g 36W/40W (600mm x 600mm) square 1 No 3174
03322 type
142 ELEC-3.8.6 Supply and fixing of........ LED Slim Panel Round / Square suitable for
Recessed / Surface mounting made of diecast alluminium body with
powder coating, acrylic diffuser with Driver as per IS: 15885 (Part 2/ Sec
13) : 2012 , operating voltage range of 150 to 265 Volts AC, P.F > 0.9,
Surge protection: 2KV, THD<10%, with high power LED's having efficacy
of > 80 lumins/watt,CCT: 3000K - 5700K, minimum CRI>70, .etc.,
complete
Makes : As per list of recommended brands as category III.
MAT- a 3W 1 No 244
03323
MAT- b 6W 1 No 423
03324
MAT- c 12W 1 No 690
03325
MAT- d 15W 1 No 920
03326
MAT- e 18W 1 No 952
03327

MAT- f 24W 1 No 1196


03328
COB DOWN LIGHTS

52
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
143 ELEC-3.8.7 Supply and fixing of........ LED COB Down lighter, suitable for Recessed
mounting made of presssure diecast alluminium housing with powder
coating, with high efficiency reflector , operating voltage range of 150 to
265 Volts AC, P.F > 0.9, Surge protection: 2KV, THD<10% with high
power LED's having efficacy of > 120 lumins/watt,CCT: 3000K - 5700K,
minimum CRI>70, .etc., complete
Makes : As per list of recommended brands as category I.
MAT- a 9 / 10 W 1 No 1242
03329
MAT- b 15 / 16 W 1 No 1610
03330
MAT- c 18 / 20 W 1 No 1794
03331
MAT- d 30 W 1 No 2852
03332
MAT- f 45 W 1 No 3128
03333
144 ELEC-3.8.8 Supply and fixing of ........ LED COB Down lighter, suitable for Recessed
mounting made of pressurediecast alluminium housing with powder
coating, with high efficiency reflector , operating voltage range of 150 to
265 Volts AC, P.F > 0.9, Surge protection: 2KV, THD<10% with high
power LED's having efficacy of > 120 lumins / watt, CCT: 3000K - 5700K,
minimum CRI>70, etc., complete.
Makes : As per list of recommended brands as category II.
MAT- a 9 / 10 W 1 No 1196
03334
MAT- b 15/ 16W 1 No 1518
03335
MAT- c 18 / 20W 1 No 1702
03336
MAT- d 30W 1 No 2760
03337
SPOT LIGHTS / WALL WASHERS

145 ELEC-3.8.9 Supply and Transportation of ........ LED COB Spot Light, suitable for
Recessed mounting made of diecast alluminium body with powder
coating, with Driver, operating voltage range of 150 to 265 Volts AC,
CCT: 3000K - 5700K, minimum CRI>70, .etc., complete
Makes : As per list of recommended brands as category I.
MAT- a 2/3 W 1 No 414
03338
MAT- b 5/6 W 1 No 506
03339
MAT- c 7W 1 No 966
03340

53
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
146 ELEC-3.8.10 Supply and fixing of ........ LED COB Spot Light, suitable for Recessed
mounting made of diecast alluminium body with powder coating, with
Driver, operating voltage range of 150 to 265 Volts AC, CCT: 3000K -
5700K, minimum CRI>70, .etc., complete
Makes : As per list of recommended brands as category II.

MAT- a 2/3 W 1 No 368


03341
MAT- b 5/6 W 1 No 460
03342
MAT- c 7W 1 No 920
03343
147 ELEC-3.8.11 Supply and fixing of........ LED single colour Wall
washer, 1000mm length, IP65, made of diecast
alluminium body with powder coating, with Driver,
operating voltage range of 150 to 265 Volts AC, CCT:
3000-4000K , beam angle 25/45 degrees, minimum
CRI>70, .etc., complete
Makes : As per list of recommended brands as
category I.
MAT- a 18W 1 No 3772
03344
MAT- b 24W 1 No 4416
03345
148 ELEC-3.8.12 Supply and fixing of........ LED single colour Wall washer, 1000mm length,
IP67, made of diecast alluminium body with powder coating, with
Driver, operating voltage range of 150 to 265 Volts AC, CCT: 3000-
4000K , beam angle 15/25/45/60 degrees, minimum CRI>70, .etc.,
complete
Makes : As per list of recommended brands as category II.
MAT- a 18W 1 No 3496
03346
MAT- b 24W 1 No 4278
03347
LED BATTENs AND 2' x 2'
LUMINARIES
149 MAT- ELEC-3.8.13 Supply and fixing of 20-24W, not less 1 No 736
03348 than 1100mm length LED batten light
with extruded alluminium housing and
polycarbonate cover, input voltage
AC 220 - 260 Volts with PF>0.9,
Surge protection: 2KV,THD<15%,
with inbuilt driver and frosted cover
CCT: 3000K - 5700K, minimum
CRI>70, .etc., complete.
Makes : As per list of recommended
brands as category I.

54
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
150 MAT- ELEC-3.8.14 Supply and fixing of 20-24W, not less 1 No 662
03349 than 1100mm length LED batten light
with extruded alluminium housing and
polycarbonate cover, input voltage
AC 220 - 260 Volts with PF>0.9,
Surge protection: 2KV,THD<15%,
with inbuilt driver and frosted cover
CCT: 3000K - 5700K, minimum
CRI>70, .etc., complete.
Makes : As per list of recommended
brands as category II.
151 MAT- ELEC-3.8.15 Supply and fixing of 20-24W, not less 1 No 552
03350 than 1100mm length LED batten light
with extruded alluminium housing and
polycarbonate cover, input voltage
AC 220 - 260 Volts with PF>0.9,
Surge protection: 2KV,THD<15%,
with inbuilt driver and frosted cover
CCT: 3000K - 5700K, minimum
CRI>70, .etc., complete.
Makes : As per list of recommended
brands as category III.
152 MAT- ELEC-3.8.16 Supply and fixing of 20W,2000 1 No 653
03351 lumens T8, , not less than 1100 mm
length LED retrofit tube light with
aluminium anodised body, input
voltage AC 220 - 260 Volts with
PF>0.9, Surge protection:
2KV,THD<10%, with inbuilt driver and
frosted cover CCT: 3000K - 5700K,
minimum CRI>70, .etc., complete. as
per IS 10322 (Part 5/ Sec 1)..2012
Makes : As per list of recommended
brands as category I.
153 MAT- ELEC-3.8.17 Supply and fixing of 20W,1900 1 No 598
03352 lumens T8,not less than 1100mm
length LED retrofit tube light with
aluminium anodised body, input
voltage AC 220 - 260 Volts with
PF>0.9, Surge protection:
2KV,THD<10%, with inbuilt driver and
frosted cover CCT: 3000K - 5700K,
minimum CRI>70, .etc., complete as
per IS 10322 (Part 5/ Sec 1)..2012
Makes : As per list of recommended
brands as category II.
154 MAT- ELEC-3.8.18 Supply of not less than 1100mm 1 No 267
03353 length,Box type powder coated tube
light luminaire with necessary wiring
suitable for fixing 2 Nos retrofit T8
LED tubes but without tube and
choke.
Makes : As per list of recommended
brands.

55
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
155 MAT- ELEC-3.8.19 Supply of not less than 1100mm 1 No 230
03354 length,Box type powder coated tube
light luminaire with necessary wiring
suitable for fixing 1 No retrofit T8 LED
tube but without tube and choke.
Makes : As per list of recommended
brands.
156 ELEC-3.8.20 Supply, transportation and fixing of ......... Recessed / Surface mounting 2'
x 2' (600x600 mm) LED luminaire made of CRCA sheet housing with
powder coated with acrylic diffuser, Constant current Driver as per IS:
15885 (Part 2/ Sec 13) : 2012 , With System lumen output ≥ 3200lm
operating voltage range of 150 to 265 Volts AC, P.F > 0.9, Surge
protection: 2KV, THD<10%, with high power LED's having efficacy of >
100 lumens / watt, CCT: 3000K - 5700K, minimum CRI>70, .etc.,,
complete.
Makes : As per list of recommended brands as category I.

MAT- a 36 W 1 No 3220
03355
MAT- b 45 W 1 No 3588
03356
157 ELEC-3.8.21 Supply, transportation and fixing of ....... Recessed / Surface mounting 2'
x 2' ' (600x600 mm)LED luminaire made of CRCA sheet housing with
powder coated with acrylic diffuser, Constant current out put of Driver as
per IS: 15885 (Part 2/ Sec 13) : 2012 operating voltage range of 150 to
265 Volts AC, Power factor > 0.9 high power LEDs having efficacy of >
90 lumens/watt, junction temparature less than 85 degrees centigrade
and THD is less than 10% etc., complete.
Makes : As per list of recommended brands as category II.

MAT- a 36 W 1 No 3036
03357
MAT- b 45 W 1 No 3404
03358
MAT- ELEC-3.8.22 Supply of 10W LED Bulk head fitting 1 No 1012
03359 with Pressure die cast alluminum with
opal diffuser with IP 65 Protection
etc., complete.,
Makes : As per list of recommended
brands as category I.

56
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
ELEC-3.8.22 Supply, Transportation and Fixing of ........W, 1100mm
length Linear Profile LED Luminaire recessed/surface
mounted with Aluminum extrusion, powder coated
cover, input voltage AC 90-270 Volts with PF>0.95,
with high power LEDs having efficacy of ≥ 100 lumens
/ watt, System efficacy >95 lm/W, surge protection:
2KV, THD<15%, with inbuilt driver and frosted cover
CCT: 3000K - 5700K, minimum CRI>70, .etc.,
complete including fixing of 23W Linear light duly
recessed in the ceiling/surface mounted by hanging
from ceiling with necessary mounting arrangements,
jointing kit, conecting wire leads etc., and all
accessories, giving connections and all labour
charges etc., complete.
Makes : As per list of recommended brands.
a 20/25W 1 No 3150

MAT-
08766
b 40W 1 No 5400

MAT-
08767
LED STREET LIGHTS

158 ELEC-3.8.23 Supply and transportation of ......... LED Street light


Luminaire made of pressure diecast alluminium body
with powder coated, having protective toughned
glass, Supply Input voltage 120 - 270 V AC, P.F >
0.90, high power LED's having System efficacy > 100
lm/W and junction temprature < 70°C, with Ingrees
protection IP66, Luminaire performance complies to
IS 10322 (Part 5 / Sec-3), Driver surge protection
4KV, In house additional Surge protection 10 KV with
optics distribution , THD<10% at 110 Volts AC, driver
efficiency >90%, CCT: 3000K - 5700K, minimum
CRI>70, etc., complete.
Makes : As per list of recommended brands as
category I.

MAT- a 20W 1 No 1822


03360
MAT- b 30W 1 No 2852
03361
MAT- c 45W 1 No 4324
03362
MAT- d 60W 1 No 5428
03363

57
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
159 ELEC-3.8.24 Supply and transportation of ......... LED Street light
Luminaire made of pressure diecast alluminium body
with powder coated, having protective toughned
glass, Supply Input voltage 120 - 270 V AC, P.F >
0.90, high power LED's System efficacy >110 lm/W
and junction temprature < 70°C, with Ingrees
protection IP66, Luminaire performance complies to
IS 10322 (Part 5 / Sec-3), Driver surge protection
4KV, In house additional Surge protection 10 KV with
optics distribution , THD<10% at 110 Volts AC, driver
efficiency >90%, CCT: 3000K - 5700K, minimum
CRI>70, etc., complete .
Makes : As per list of recommended brands as
category I.

MAT- a 90W 1 No 8464


03364
MAT- b 120W 1 No 10948
03365
MAT- c 150W 1 No 12650
03366
MAT- d 180W 1 No 14260
03367
MAT- e 210W 1 No 18400
03368
160 ELEC-3.8.25 Supply and transportation of .........LED Street light Luminaire made of
pressure diecast alluminium body with powder coated, having protective
toughned glass, Supply Input voltage 120 - 270 V AC, P.F > 0.90, high
power LED's System efficacy >100lm/W and junction temprature < 70°C,
with Ingrees protection IP65, Luminaire performance complies to IS
10322 (Part 5 / Sec-3), Driver surge protection 4KV, In house additional
Surge protection ≥ 10KV with optics distribution , THD<10% at 110 Volts
AC, driver efficiency >90%, CCT: 3000K - 5700K, minimum CRI>70,
etc., complete,
Makes : As per list of recommended brands as category II.
MAT- a 20W 1 No 1702
03369
MAT- b 30W 1 No 2650
03370
MAT- c 45W 1 No 4140
03371
MAT- d 60W 1 No 5152
03372
MAT- e 90W 1 No 8004
03373
MAT- f 120W 1 No 9660
03374
MAT- g 150W 1 No 11592
03375

58
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- h 180W 1 No 13248


03376
MAT- i 210W 1 No 16146
03377
161 ELEC-3.8.26 Supply and transportation of ......... .LED Street light Luminaire made of
pressure diecast alluminium body with powder coated, having protective
toughned glass, Supply Input voltage 120 - 270 V AC, P.F > 0.90, high
power LED's having System efficacy >90 lm/W and junction temprature <
70°C, with Ingrees protection IP66, Luminaire performance complies to IS
10322 (Part 5 / Sec-3), Driver surge protection 4KV, In house additional
Surge protection ≥ 10KV with optics distribution Type II medium,
THD<10% at 110 Volts AC, driver efficiency >90%, w, CCT: 3000K -
5700K, minimum CRI>70, etc., complete.
Makes : As per list of recommended brands as category III.

MAT- a 20W 1 No 1615


03378
MAT- b 30W 1 No 2346
03379
MAT- c 45W 1 No 3864
03380
MAT- d 60W 1 No 4784
03381
MAT- e 90W 1 No 7452
03382
MAT- f 120W 1 No 8740
03383
FLOOD LIGHTS

162 ELEC-3.8.27 Supply and transportation of ......... LED Flood light Luminaire made of
pressure diecast alluminium housing with powder coated,having
protective toughned glass, Supply Input voltage 120 - 270 V AC, P.F >
0.90, high power LED's System efficacy >100lm/W and junction
temprature < 70°C, with Ingrees protection IP66, Luminaire performance
complies to IS 10322 (Part 5 / Sec-3), IK05, Driver surge protection 4KV,
In house additional Surge protection ≥ 10KV with wide/ Narrow beam
optics, THD<10% at 110 Volts AC, driver efficiency >90%, , CCT: 3000K
- 5700K, minimum CRI>70, etc., complete
Makes : As per list of recommended brands as category I.

MAT- a 50/60W 1 No 5382


03384
MAT- b 90/100W 1 No 9522
03385
MAT- c 120W 1 No 12337
03386
MAT- d 150W 1 No 14490
03387

59
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- e 200W 1 No 17388


03388
MAT- f 250W 1 No 20286
03389
MAT- g 300 W 1 No 24012
03390
MAT- h 400W 1 No 27738
03391
163 ELEC-3.8.28 Supply and transportation of ......... LED Flood light Luminaire made of
pressure diecast alluminium housing with powder coated,having
protective toughned glass, Supply Input voltage 120 - 270 V AC, P.F >
0.90, high power LED's System efficacy >100lm/W and junction
temprature < 70°C, with Ingrees protection IP66, Luminaire performance
complies to IS 10322 (Part 5 / Sec-3), IK05, Driver surge protection 4KV,
In house additional Surge protection ≥ 10KV with wide/ Narrow beam
optics, THD<10% at 110 Volts AC, driver efficiency >90%, , CCT: 3000K
- 5700K, minimum CRI>70, etc., complete
Makes : As per list of recommended brands as category II.

MAT- a 50/60W 1 No 4802


03392
MAT- b 90/100W 1 No 8694
03393
MAT- c 120W 1 No 11178
03394
MAT- d 150W 1 No 13248
03395
MAT- e 200W 1 No 15732
03396
HIGH BAY LIGHTS

164 ELEC-3.8.29 Supply and transportation of ......... LED HIgh Bay Luminaire with high
power COB LED made of pressure diecast alluminium housing with
powder coated,Supply Input voltage 120 - 270 V AC, P.F > 0.90, high
power LED's having efficacy >100 lumines/watt, System efficacy
>95lm/W and junction temprature < 70°C, with Ingrees protection IP66,
IK05, Driver surge protection 4KV, In house additional Surge protection
≥ 5KV with wide/ Narrow beam optics, THD<10% at 110 Volts AC, driver
efficiency >90%, , CCT: 3000K - 5700K, minimum CRI>70, etc.,
complete
Makes : As per list of recommended brands as category I.
MAT- a 60W 1 No 7820
03400
MAT- b 90W 1 No 10120
03401
MAT- c 120W 1 No 11500
03402
MAT- d 150W 1 No 13340

60
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03403

165 ELEC-3.8.30 Supply and transportation of ......... LED HIgh Bay Luminaire with high
power COB LED made of pressure diecast alluminium housing with
powder coated,Supply Input voltage 120 - 270 V AC, P.F > 0.90, high
power LED's having efficacy >100 lumines/watt, System efficacy
>95lm/W and junction temprature < 70°C, with Ingrees protection IP65,
IK05, Driver surge protection 4KV, In house additional Surge protection
≥ 5KV with wide/ Narrow beam optics, THD<10% at 110 Volts AC, driver
efficiency >90%, , CCT: 3000K - 5700K, minimum CRI>70, etc.,
complete
Makes : As per list of recommended brands as category II.

MAT- a 60W 1 No 7360


03404
MAT- b 90W 1 No 9016
03405
MAT- c 120W 1 No 10580
03406
MAT- d 150W 1 No 12420
03407
ELEC-3.8.31 Supply and transportation of ......... LED Linear Wall washer of Size
.................. mm with high power LED's made of pressure diecast
alluminium housing with powder coated,Supply Input voltage 120 - 270
V AC,leads to 24 V DC out put Voltage Drives with beam angle of
15/25/45/60 , P.F > 0.90, having efficacy >100 lumens/watt, System
efficacy >95lm/W and junction temprature < 70°C, with Ingrees protection
IP66, IK05, with multi colour(Red or Yellow or Green or blue or White)
etc., complete
Makes : As per list of recommended brands.
MAT- a 18 W , 1000 X 38 X 58 mm 1 No 8648
05492
MAT- b 24 W , 1000 X 38 X 58 mm 1 No 9108
05493
MAT- c 36 W , 1000 X 38 X 86 mm 1 No 10580
05494
MAT- d 48 W , 1000 X 60 X 100 mm 1 No 12788
05495
RGB/RGBW LED Lighting

ELEC-3.8.32 Supply and transportation of IP 66 RGBW LED Flood light Luminaries


made of pressure die cast aluminium housing with powder coated,
having protective toughened glass, Supply Input voltage 120 - 270 V
AC, leads to 24 V DC output Voltage drives RGB LED’s with light angle
60°, surge protection 6KV and junction temperature < 70°C,
CRI>70,P.F>0.9,suitable for RGB DMX 512 controller etc., complete
Makes : As per list of recommended brands.

MAT- a 90W 1 No 23460


05496

61
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b 120W 1 No 26680


05497
ELEC-3.8.33 Supply and transportation of ......... RGB LED Linear Wall washer of
Size .................. mm with high power LED's made of pressure diecast
alluminium housing with powder coated,Supply Input voltage 120 - 270
V AC,leads to 24 V DC out put Voltage Drives with beam angle of
15/25/45/60 , P.F > 0.90, having efficacy >100 lumens/watt, System
efficacy >95lm/W and junction temprature < 70°C, with Ingrees protection
IP66, IK05,suitable for RGB DMX 512 controller etc.,
Makes : As per list of recommended brands.

MAT- a 18 W , 1000 X 38 X 58 mm 1 No 10304


05498
MAT- b 24 W , 1000 X 38 X 58 mm 1 No 10856
05499
MAT- c 36 W , 1000 X 38 X 58 mm 1 No 12144
05500
MAT- d 48 W , 1000 X 60 X 100 mm 1 No 15364
05501
MAT- ELEC-3.8.34 Supply,transportation and installation 1 No 78000
05502 of stand alone USB -DMX controller to
control a wide variety of different DMX
systems from RGB/RGbW ,including
1024 DMX channels,Input power 5-
5.5 V DC 0.6 A with programmability
on PC ,MAC,tablet,smart phone with
micro SD card etc complete
Makes : As per list of recommended
brands.
MAT- ELEC-3.8.35 Supply,Transportation and Installation 1 No 16000
05503 of DMX splitter/booster in the existing
junction box with necessary
connections.
Makes : As per list of recommended
brands.
MAT- ELEC-3.8.36 Supply,Transportation and Installation 1 No 5200
05504 of DMX-DC-5A,Decoder in the
existing junction box with necessary
connections.
Makes : As per list of recommended
brands.
MAT- ELEC-3.8.37 Supply,Transportation and Installation 1 No 3900
05505 of DC 24V input DMX Data Repeater
in the existing junction box with
necessary connections.
Makes : As per list of recommended
brands.

62
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-3.8.38 Supply,Transportation and Installation 1 No 4900


05506 of 350W,non-water proof,DC 24V
Constant Voltage Power
Supply(Driver) Unit in the existing
junction box with necessary
connections. Makes : As per list of
recommended brands.

MAT- ELEC-3.8.39 Supply,Transportation and Installation 1 No 3200


05507 of 350W,non-water proof,DC 12V,1.25
A Constant Voltage Power
Supply(Driver) Unit in the existing
junction box with necessary
connections.
Makes : As per list of recommended
brands.

LED DRIVERS

166 ELEC-3.8.40 Supply and transportation of LED Driver as per IS 15885 (Part 2 / Sec
13)..2012 with input line voltage 120V-270V AC, 50Hz with surge
protection more than 2.5 KV, IP20, suitable for …….. LED indoor
luminaire, with 2 Years Warranty.
Makes : As per list of recommended brands.
MAT- a 6/9 W 1 No 225
03408
MAT- b 12/15/18/20 W 1 No 325
03409
MAT- c 36 W 1 No 475
03410
MAT- d 40/45 W 1 No 575
03411
167 ELEC-3.8.41 Supply and transportation of LED Driver as per IS 15885 (Part 2 / Sec
13)..2012 with input line voltage 120V-270V AC, 50Hz with surge
protection of 4.0 KV, IP20, suitable for …………. LED street light fitting
with 2 Years Warranty.
Makes : As per list of recommended brands.
MAT- a 15-30 W 1 No 350
03412
MAT- b 45-90 W 1 No 800
03413
MAT- c 120-180 W 1 No 1400
03414
SECTION - 4

4.1 U.G. CABLES

168 ELEC-4.1.1 Supply and transportation of following XLPE insulated, 1100V grade
armoured alluminium cable as per specification confirming to IS:7098
(Part - I)./1554-I

63
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Makes : As per list of recommended brands as category I.

MAT- a 4 sqmm X2 core 1 RM 105


03415
MAT- b 6 sqmm X2 core 1 RM 121
03416
MAT- c 10 sqmm X2 core 1 RM 143
03417
MAT- d 6 SqmmX 4 core 1 RM 143
03418
MAT- e 10SqmmX 4 core 1 RM 165
03419
MAT- f 16 SqmmX 4 core 1 RM 182
03420
MAT- g 25 SqmmX 3.5 core 1 RM 231
03421
MAT- h 35SqmmX 3.5 core 1 RM 275
03422
MAT- i 50 SqmmX 3.5 core 1 RM 358
03423
MAT- j 70 SqmmX 3.5 core 1 RM 462
03424
MAT- k 95 SqmmX 3.5 core 1 RM 600
03425
MAT- l 120 SqmmX 3.5 core 1 RM 726
03426
MAT- m 150 SqmmX 3.5 core 1 RM 836
03427
MAT- n 185 SqmmX 3.5 core 1 RM 1023
03428
MAT- o 240 SqmmX 3.5 core 1 RM 1271
03429
MAT- p 300SqmmX 3.5 core 1 RM 1540
03430
MAT- q 400SqmmX 3.5 core 1 RM 1964
03431
169 ELEC - 4.1.2 Supply and transportation of following XLPE insulated, 1100V grade
armoured alluminium cable as per specification confirming to IS:7098
(Part - I)./1554-I.
Makes : As per list of recommended brands as category II.
MAT- a 4 sqmm X2 core 1 RM 88
03432
MAT- b 6 sqmm X2 core 1 RM 99
03433

64
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 10 sqmm X2 core 1 RM 121


03434
MAT- d 6 SqmmX 4 core 1 RM 127
03435
MAT- e 10SqmmX 4 core 1 RM 139
03436
MAT- f 16 SqmmX 4 core 1 RM 155
03437
MAT- g 25 SqmmX 3.5 core 1 RM 198
03438
MAT- h 35SqmmX 3.5 core 1 RM 231
03439
MAT- i 50 SqmmX 3.5 core 1 RM 306
03440
MAT- j 70 SqmmX 3.5 core 1 RM 394
03441
MAT- k 95 SqmmX 3.5 core 1 RM 515
03442
MAT- l 120 SqmmX 3.5 core 1 RM 633
03443
MAT- m 150 SqmmX 3.5 core 1 RM 726
03444
MAT- n 185 SqmmX 3.5 core 1 RM 869
03445
MAT- o 240 SqmmX 3.5 core 1 RM 1100
03446
MAT- p 300SqmmX 3.5 core 1 RM 1331
03447
MAT- q 400SqmmX 3.5 core 1 RM 1727
03448
33 KV HT XLPE CABLES

170 ELEC-4.1.3 Supply and Transportation of XLPE insulated IS:7098/II/85 H.T.cable for
working voltage 33 K.V.Earthed with Stranded Compacted Circular
Aluminium Conductor Screened with Extruded Semi-conducting
compound, XLPE Insulated Screened with extruded semi-conducting
compound in combination with Copper Tape, cores laid up, inner sheath
of Thermoplastic tape, galvanised flat steel strip armoured and overall
Extruded PVC Type ST- 2 Outer Sheathed cable etc complete.
Makes : As per list of recommended brands.

MAT- a 3C X 95 Sqmm 1 RM 1584


03449
MAT- b 3C X 120 Sqmm 1 RM 1760
03450

65
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 3C X 150 Sqmm 1 RM 1925


03451
MAT- d 3C X 185 Sqmm 1 RM 2112
03452
MAT- e 3C X 240 Sqmm 1 RM 2420
03453
MAT- f 3C X 300 Sqmm 1 RM 2717
03454
MAT- g 3C X 400 Sqmm 1 RM 3124
03455
11 KV HT XLPE CABLES

171 ELEC- 4.1.4 Supply and Transportation of XLPE insulated IS:7098/II/85 H.T.cable for
working voltage 11 K.V Earthed with Stranded Compacted Circular
Aluminium Conductor Screened with Extruded Semi-conducting
compound, XLPE Insulated Screened with extruded semi-conducting
compound in combination with Copper Tape, cores laid up, inner sheath
of Thermoplastic tape, galvanised flat steel strip armoured and overall
Extruded PVC Type ST- 2 Outer Sheathed cable etc complete.
Makes : As per list of recommended brands.

MAT- a 3C X 35 Sqmm 1 RM 649


03456
MAT- b 3C X 50 Sqmm 1 RM 737
03457
MAT- c 3C X 70 Sqmm 1 RM 869
03458
MAT- d 3C X 95 Sqmm 1 RM 1029
03459
MAT- e 3C X 120 Sqmm 1 RM 1155
03460
MAT- f 3C X 150 Sqmm 1 RM 1331
03461
MAT- g 3C X 185 Sqmm 1 RM 1562
03462
MAT- h 3C X 240 Sqmm 1 RM 1793
03463
MAT- i 3C X 300 Sqmm 1 RM 2013
03464
MAT- j 3C X 400 Sqmm 1 RM 2530
03465
Un Armoured and Armoured
Copper Control Cables
172 ELEC-4.1.5 Supply and Transportation of XLPE/PVC insulated & PVC sheathed
unarmoured control cables of 1.1 KV grade with copper conductor as per
IS 7098 Part-I -1988 etc complete

66
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Makes : As per list of recommended brands.

MAT- a 2C x 1.5 sq.mm 1 RM 104


03466
MAT- b 3C x 1.5 sq.mm 1 RM 109
03467
MAT- c 4C x 1.5 sq.mm 1 RM 127
03468
MAT- d 5C x 1.5 sq.mm 1 RM 132
03469
MAT- e 6C x 1.5 sq.mm 1 RM 150
03470
MAT- f 8C x 1.5 sq.mm 1 RM 173
03471
MAT- g 10C x 1.5 sq.mm 1 RM 219
03472
MAT- h 12C x 1.5 sq.mm 1 RM 242
03473
MAT- i 14C x 1.5 sq.mm 1 RM 270
03474
MAT- j 19C x 1.5 sq.mm 1 RM 339
03475
MAT- k 2C x 2.5 sq.mm 1 RM 115
03476
MAT- l 3C x 2.5 sq.mm 1 RM 132
03477
MAT- m 4C x 2.5 sq.mm 1 RM 155
03478

MAT- n 5C x 2.5 sq.mm 1 RM 173


03479
MAT- o 6C x 2.5 sq.mm 1 RM 242
03480
MAT- p 8C x 2.5 sq.mm 1 RM 288
03481
MAT- q 10C x 2.5 sq.mm 1 RM 334
03482
MAT- r 12C x 2.5 sq.mm 1 RM 374
03483
MAT- s 14C x 2.5 sq.mm 1 RM 420
03484
MAT- t 19C x 2.5 sq.mm 1 RM 489

67
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03485

173 ELEC-4.1.6 Supply and Transportation of XLPE/PVC insulated & PVC sheathed
armoured cables of 1.1 KV grade with copper conductor as per IS 7098
Part-I -1988 etc complete.
Makes : As per list of recommended brands.
MAT- a 2Cx1.5 sq.mm 1 RM 109
03486
MAT- b 2Cx2.5 sq.mm 1 RM 115
03487
MAT- c 2C x 4 sq.mm 1 RM 144
03488
MAT- d 2C x 6 sq.mm 1 RM 207
03489
MAT- e 2C x 10 sq.mm 1 RM 288
03490
MAT- f 2C x 16 sq.mm 1 RM 397
03491
MAT- g 3C x 4 sq.mm 1 RM 182
03492
MAT- h 3C x 6 sq.mm 1 RM 242
03493
MAT- i 3C x 10 sq.mm 1 RM 301
03494
MAT- j 3C x 16 sq.mm 1 RM 423
03495
MAT- k 4C x 4 sq.mm 1 RM 253
03496
MAT- l 4C x 6 sq.mm 1 RM 362
03497
MAT- m 4C x 10 sq.mm 1 RM 543
03498
MAT- n 4C x 16 sq.mm 1 RM 903
03499
MAT- o 4C x 25 sq.mm 1 RM 1449
03500
MAT- p 4C x 35 sq.mm 1 RM 1932
03501
MAT- q 4C x 50 sq.mm 1 RM 2777
03502
MAT- r 4C x 70 sq.mm 1 RM 4226
03503
CABLE TERMINATIONS AND
ACCESSORIES

68
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
174 ELEC-4.1.7 Supply and Making heat shrinkable type indoor/ outdoor/straight through
terminations/joint kit of approved make suitable for XLPE insulated 33 KV
cable, with required components, prepration of cable ends, testing etc. as
required of following sizes.
Makes : As per list of recommended brands.
INDOOR

MAT- a 3 Core 95/120/150/185 sq mm Set 13283


03504
MAT- b 3 core 240/300/400 sqmm Set 18480
03505
OUTDOOR

MAT- c 3 Core 95/120/150/185 sq mm Set 18480


03506
MAT- d 3 core 240/300/400 sqmm Set 25988
03507
STRAIGHT THROUGH

MAT- e 3 Core 95/120/150/185 sq mm Set 37538


03508
MAT- f 3 core 240/300/400 sqmm Set 54863
03509
175 ELEC-4.1.8 Supply and Making heat shrinkable type indoor /outdoor/straight through
terminations/ joint kit of approved make suitable for XLPE insulated 11
KV cable, with required components, prepration of cable ends, testing
etc. as required of following sizes.
Makes : As per list of recommended brands.
INDOOR

MAT- a 3 core 35/50 sqmm Set 5775


03510
MAT- b 3 core 70/95 sqmm Set 8663
03511
MAT- c 3 core 120/150/185 sqmm Set 9818
03512
MAT- d 3 core 240/300 sqmm Set 10280
03513
MAT- e 3 core 400/500 sqmm Set 10857
03514
OUTDOOR

MAT- f 3 core 35/50 sqmm Set 9818


03515
MAT- g 3 core 70/95 sqmm Set 12128
03516
MAT- h 3 core 120/150/185 sqmm Set 13283
03517

69
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- i 3 core 240/300 sqmm Set 14438


03518
MAT- j 3 core400/500 sqmm Set 16170
03519
STRAIGHT THROUGH

MAT- k 3 core 35/50 sqmm Set 15593


03520
MAT- l 3 core 70/95 sqmm Set 18480
03521
MAT- m 3 core 120/150/185 sqmm Set 21368
03522
MAT- n 3 core 240/300 sqmm Set 23100
03523
176 ELEC-4.1.9 Supply & Making heat shrinkable outdoor straight through joint for
following size of PVC/ XLPE insulated aluminium conductor cable of 1.1
KV grade including cost of compound, sleeves etc. as required.
Makes : As per list of recommended brands.
MAT- a 3.5core x 25/35/50 sq.mm Set 1733
03524
MAT- b 3.5 corex 70/95/120 sq.mm Set 2772
03525
MAT- c 3.5 corex 150/185/240 sq.mm Set 4043
03526
MAT- d 3.5core x 300/400 sq.mm Set 6353
03527
MAT- e 4 corex 6/10/16 sq.mm Set 924
03528
177 ELEC-4.1.10 Supply and making one end termination with heavy duty double
compression brass gland as per BS 6121:2005 ,IP 66 complete,SIBG
type, heavy duty Alluminium lugs duly crimped with crimping tool, PVC
tape etc for following size of Armoured PVC insulated & PVC sheathed/
XLPE aluminium conductor cable of 1100 volt grade as required of size.
Makes : As per list of recommended brands.
MAT- a 3.5core x 25 sq.mm Set 248
03529
MAT- b 3.5core x 35 sq.mm Set 330
03530
MAT- c 3.5 corex 50 sq.mm Set 385
03531
MAT- d 3.5core x 70 sq.mm Set 572
03532
MAT- e 3.5core x 95 sq.mm Set 655
03533
MAT- f 3.5core x 120 sq.mm Set 825

70
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03534

MAT- g 3.5core x 150 sq.mm Set 990


03535
MAT- h 3.5core x 185 sq.mm Set 1100
03536
MAT- i 3.5core x 240sq.mm Set 1650
03537
MAT- j 3.5core x 300 sq.mm Set 1980
03538
MAT- k 3.5core x 400 sq.mm Set 2640
03539
MAT- l 4 core x 6/10/16 sq.mm Set 253
03540
178 ELEC-4.1.11 Supply and making one end termination with heavy duty single
compression brass gland as per BS 6121:2005 ,IP 66 complete, SIBG
type, heavy duty Alluminium lugs duly crimped with crimping tool, PVC
tape etc for following size of Armoured PVC insulated & PVC sheathed/
XLPE aluminium conductor cable of 1100 volt grade as required of size.
Makes : As per list of recommended brands.
MAT- a 2 coreX4/6/10 sqmm Set 72
03541
MAT- b 4 coreX6/10/16 Sqmm Set 94
03542
MAT- c 3.5 coreX25 Sqmm Set 110
03543
MAT- d 3.5 coreX 35Sqmm Set 165
03544
MAT- e 3.5 coreX50 Sqmm Set 176
03545
MAT- f 3.5 coreX70 Sqmm Set 193
03546
MAT- g 3.5 coreX95 Sqmm Set 231
03547
MAT- h 3.5 coreX120 Sqmm Set 275
03548
MAT- i 3.5 coreX150 Sqmm Set 495
03549
MAT- j 3.5 coreX185 Sqmm Set 605
03550
MAT- k 3.5 coreX240 Sqmm Set 715
03551
MAT- l 3.5 coreX300Sqmm Set 990
03552

71
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- m 3.5 coreX400Sqmm Set 1320


03553
180 ELEC-4.1.12 Supply and making end termination with heavy copper lugs (pin/ ring
type) as per IS specification, duly crimped with crimping tool, PVC tape
etc of followingsize
Makes : As per list of recommended brands.
MAT- a up to 16 sqmm each 23
03554
MAT- b 25 Sqmm each 31
03555
MAT- c 35Sqmm each 35
03556
MAT- d 50 Sqmm each 52
03557
MAT- e 70 Sqmm each 78
03558
MAT- f 95 Sqmm each 101
03559
181 ELEC-4.1.13 Supply and making end termination with heavy Alluminium lugs (pin/ ring
type) as per IS specification duly crimped with crimping tool, PVC tape
etc of following size
Makes : As per list of recommended brands.
MAT- a up to 16 sqmm each 11
03560
MAT- b 25 Sqmm each 17
03561
MAT- c 35Sqmm each 22
03562
MAT- d 50 Sqmm each 28
03563
MAT- e 70 Sqmm each 33
03564
MAT- f 95 Sqmm each 39
03565
MAT- g 120 Sqmm each 44
03566
MAT- h 150 Sqmm each 50
03567
MAT- i 185 Sqmm each 61
03568
MAT- j 240 Sqmm each 88
03569
MAT- k 300 Sqmm each 110
03570

72
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- l 400 Sqmm each 187


03571
4.2 CABLE TRAYS

182 ELEC-4.2.1 Supply,transporatation & installation of following sizes of Hot Dipped


Galvanized Iron perforated cable trays without cover, including
horizontal and vertical bends, reducers tees,cross members and other
accessories as required and duly suspended from the ceiling/Wall with
suspenders etc., complete
(NB:Add 30% Extra for perforated cable tray with cover)
MAT- a 100mm x 50mm x 1.6mm 1 RM 308
03572
MAT- b 150mm x 50mm x 1.6mm 1 RM 358
03573
MAT- c 300mm x 50mm x 1.6mm 1 RM 660
03574
MAT- d 450mm x 50mm x 2.0mm 1 RM 957
03575
MAT- e 600mm x 50mm x 2.0mm 1 RM 1095
03576
MAT- f 300mm x 62.5mm x 2.0mm 1 RM 792
03577

MAT- g 450mm x 62.5mm x 2.0mm 1 RM 1062


03578
MAT- h 600mm x 62.5mm x 2.0mm 1 RM 1315
03579
MAT- i 750mm x 62.5mm x 2.0mm 1 RM 1557
03580
MAT- j 900mm x 62.5mm x 2.0mm 1 RM 1848
03581
MAT- k 600mm x 75mm x 2.0mm 1 RM 1469
03582
MAT- l 750mm x 75mm x 2.0mm 1 RM 1617
03583
MAT- m 900mm x 75mm x 2.0mm 1 RM 1903
03584
183 ELEC-4.2.2 Supply,transporatation & installation of following sizes of Hot Dipped
Galvanized Iron ladder type cable trays with rungs at span of 250 mm
including horizontal and vertical bends, reducers tees,cross members
and other accessories as required and duly suspended from the
ceiling/wall with suspenders and etc., complete
MAT- a 150mm x 50mm x 2.0mm 1 RM 451
03585
MAT- b 300mm x 50mm x 2.0mm 1 RM 567
03586

73
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 450mm x 50mm x 2.0mm 1 RM 748


03587
MAT- d 600mm x 75mm x 2.0mm 1 RM 924
03588
MAT- e 750mm x 75mm x 2.0mm 1 RM 979
03589
MAT- f 900mm x 75mm x 2.0mm 1 RM 1040
03590
4.3 DOUBLE WALLED CORRUGATED
HDPE PIPE
184 ELEC-4.3.1 Supply and Transportation of ……….. ……. double walled corrugated
HDPE duct made as per specification BSEN - 500 86/IS 14930 Part-II.
Makes : As per list of recommended brands.
MAT- a Outer dia 50mm and Inner dia 38mm 1 RM 99
03591
MAT- b Outer dia 63mm and Inner dia 51mm 1 RM 127
03592
MAT- c Outer dia 78mm and Inner dia 63mm 1 RM 154
03593

MAT- d Outer dia 90mm and Inner dia 76mm 1 RM 165


03594
MAT- e Outer dia 120mm and Inner dia 1 RM 259
03595 103.5mm
MAT- f Outer dia 160 mm and Inner dia 136 1 RM 385
03596 mm
MAT- g Outer dia 180 mm and Inner dia 152 1 RM 506
03597 mm
MAT- h Outer dia 200 mm and Inner dia 170 1 RM 600
03598 mm
SECTION - 5

5.1 FANS

MAT- ELEC-5.1.1 Supply of 48" (1200mm) Sweep 5 star 1 No 3295


05508 rated BLDC (Brush less Direct
Current) Ceiling Fan with double ball
bearings, input voltage 230V AC
converted to 24 V DC, power input not
more than 32W , air delivery 210/220
cubic meter/min with remote and
without Regulator.
Makes : As per list of recommended
brands.

74
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-5.1.2 Supply of 56" (1400mm) Sweep 5 star 1 No 3845


05509 rated BLDC (Brush less Direct
Current) Ceiling Fan with double ball
bearings, input voltage 230V AC
converted to 24 V DC, power input not
more than 32W , air delivery not less
than 240 cubic meter/min with remote
and without Regulator.
Makes : As per list of recommended
brands.
185 MAT- ELEC-5.1.3 Supply of 48" (1200mm) Sweep 5 star 1 No 2300
03599 rated Ceiling Fan , with double ball
bearings, air delivery more than 200
cubic meter/min but without
Regulator.
Makes : As per list of recommended
brands.
186 MAT- ELEC-5.1.4 Supply of 48" (1200mm) Sweep 1 No 2645
03600 decorative Ceiling Fan, with double
ball bearings with all accessories
without Regulator.
Makes : As per list of recommended
brands.
187 MAT- ELEC-5.1.5 Supply of 56" (1400mm) Sweep 5 star 1 No 2760
03602 rated Ceiling Fan , with double ball
bearings, but without Regulator.
Makes : As per list of recommended
brands.
188 MAT- ELEC-5.1.6 Supply of 16" (400mm) Wall mounted 1 No 2645
03603 Fan.
Makes : As per list of recommended
brands.
189 MAT- ELEC-5.1.7 Supply of 16" (400mm) Pedestal Fan. 1 No 2933
03604 Makes : As per list of recommended
brands.
190 MAT- ELEC-5.1.8 Supply of 18" (450mm) Wall mounting 1 No 6210
03605 / Pedestal Air Circulators.
Makes : As per list of recommended
brands.
191 MAT- ELEC-5.1.9 Supply of 24" (600mm) Wall mounting 1 No 7475
03606 / Pedestal Air Circulators.
Makes : As per list of recommended
brands.
192 MAT- ELEC-5.1.10 Supply of 12" (300mm) Cabin fan. 1 No 1955
03607 Makes : As per list of recommended
brands.

193 MAT- ELEC-5.1.11 Supply of 12" (300mm) Light duty 1 No 1668


03608 exhaust fan with metalic blades and
wire guard etc complete.
Makes : As per list of recommended
brands.

75
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
194 MAT- ELEC-5.1.12 Supply of 9" (225mm), Light duty 1 No 1484
03609 exhaust fan with double ball bearing
and wire guard etc complete.
Makes : As per list of recommended
brands.

195 MAT- ELEC-5.1.13 Supply of 12" (300mm) ISI, 900 RPM 1 No 3163
03610 Heavy duty exhaust fan with metallic
blades with Mark.
Makes : As per list of recommended
brands.

196 MAT- ELEC-5.1.14 Supply of 15" (375mm) ISI, 900 RPM 1 No 3680
03611 Heavy duty exhaust fan with metallic
blades with Mark.
Makes : As per list of recommended
brands.

197 MAT- ELEC-5.1.15 Supply of 18" (450mm) ISI, 900 RPM 1 No 4715
03612 Heavy duty exhaust fan with metallic
blades with Mark.
Makes : As per list of recommended
brands.

5.2 WATER HEATERS (Conventional &


Solar)
198 ELEC-5.2.1 Supply, Transportation and fixing of storage / Pressure type Vertical /
Horizontal 230/250V single phase 2000watts ISI mark 5 Star rated water
heater with SS tank and ABS plastic body of ........ capacity to withstand
up to 6.5 bar of water pressure including all standard accessories and
dead weight pressure reducing valve on out let side, including cost of 2
Nos nylon / PVC / Metallic hose pipe, testing and all labour charges etc.,
complete.
Makes : As per list of recommended brands.
MAT- a 15 Ltrs 1 No 10293
03613
MAT- b 25 Ltrs 1 No 12075
03614
200 ELEC-5.2.2 Supply,Transportation,erection and Commissioning of MNRE approved
and confirming to IS 12933 P-1,2,3&5......... Tube Collector type Solar
Water heating System with temperature application of 60 degrees with
Stain less steel - 304L grade inner tank with PUF Insulation and
Alluminum Cladding for Outer Cover,Suitable EPDM rubber pipe
connection from Collector to Solar Tank with electrical Heating back up
etc., with 3 years Guarantee for Solar system and additional 2 years
warranty.
Makes : As per list of recommended brands.
MAT- a 250 LPD 1 No 55660
03615
MAT- b 375LPD 1 No 77050
03616

76
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 500 LPD 1 No 87400


03617
MAT- d 1000 LPD 1 No 170200
03618
201 ELEC-5.2.3 Supply,Transportation,erection and Commissioning of MNRE approved
and confirming to IS 12933 P-1,2,3&5......... Flate plate Collector type
Solar Water heating System with temperature application of 60 degrees
with Stain less steel - 304L grade inner tank with PUF Insulation and
Alluminum Cladding for Outer Cover,Suitable EPDM rubber pipe
connection from Collector to Solar Tank with electrical Heating back up
etc., with 3 years Guarantee for Solar system and additional 2 years
warranty.
Makes : As per list of recommended brands.
MAT- a 250 LPD 1 No 59800
03619
MAT- b 375 LPD 1 No 82800
03620
MAT- c 500 LPD 1 No 96025
03621
MAT- d 1000 LPD 1 No 189750
03622
HEAT PUMP

202 ELEC-5.2.4 Supply, Transportation and fixing of Energy Efficient Heat pump(Hybrid)
water heater of Mono block storage / type Vertical / 230/250V single
phase 50 Hz rated water heater with SS tank coated with Enamel and
stain less body with IP X 4 water Proff grade of ...... capacity Mono Block
unit to withstand up to 0.8 - 1.0 MPa bar of water pressure including 2
Kw Heating element and Auto Defrosting and with 50 MM Puf insulation
with all standard accessories and dead weight pressure reducing valve
on out let side, including cost of CPVC Piping / Metallic hose pipe, testing
and all labour charges etc., complete.
Makes : As per list of recommended brands.
MAT- a 200 Ltr 1 No 125580
03623
MAT- b 300 Ltr 1 No 159390
03624
203 ELEC-5.2.5 Supply, Transportation and fixing of Energy Efficient Heat pump(Hybrid)
water heater of split type storage / type Vertical / 230/250V single phase
50 Hz rated water heater with SS tank coated with Enamel and
prepainted steel body with IP X 4 water Proff grade of ..........capacity
Mono Block unit to withstand up to 0.8 - 1.0 MPa bar of water pressure
including 2 Kw Heating element and Auto Defrosting and with 50 MM Puf
insulation with all standard accessories and dead weight pressure
reducing valve on out let side, including cost of CPVC Piping / Metallic
hose pipe, testing and all labour charges etc., complete.
Makes : As per list of recommended brands.
MAT- a 400 Ltr 1 No 154675
03625

77
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b 500 Ltr 1 No 189336


03626
5.3 ACCESSORIES FOR WATER
HEATERS
204 ELEC-5.3.1 Supply and fixing of stem type ISI marked (IS 3017 / 85) snap action
adjustable thermostat storage water heater including making connection
testing etc. as required.

MAT- a 11" stem thermostat 1 No 209


03627
MAT- b 7" stem thermostat 1 No 187
03628
205 MAT- ELEC-5.3.2 Supply and fixing of stem type, ISI 1 No 248
03629 marked, push to reset type auto
thermal cut off and rated at 20 A 250
V including testing etc. as required.
206 ELEC-5.3.3 Supply and fixing of ISI marked ( IS:4159) marked copper
sheathed,nickle plated, mineral filled heating element including making
connection testing etc as required
MAT- a 3.0 KW 1 No 715
03630
MAT- b 2.0 KW 1 No 682
03631
207 ELEC-5.3.4 Supply and fixing of twin ceremic catridge, shock and hard water proof
heating element including making connecton testing etc as required
MAT- a 3.0 KW 1 No 825
03632
MAT- b 2.0 KW 1 No 715
03633
208 ELEC-5.3.5 Supply and fixing of base plate assembly with neoprene rubber gasket,
inlet socket with inbuilt NRV/ PRV and drain out system and outlet socket
pipe,fusible plug assembly,mounting hardwares complete etc. as
required.

MAT- a 15 Ltr. To 50 Ltr. Capacity SWH 1 No 1540


03634

209 MAT- ELEC-5.3.5 Supply and fixing of heavy duty C.P. 1 set 275
03635 connection for storage water heater
for inlet and outlet of length 300-600
mm including the cost of nuts,
washers etc as required.
210 MAT- ELEC-5.3.6 Charges for brass welding of inner job 440
03636 copper tank for storage water heater
including opening,refixing,testing
etc. as required
211 MAT- ELEC-5.3.7 Charges for descaling of storage job 330
03637 water heater including
required chemical, opening, refixing,

78
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

testing as complete

212 MAT- ELEC-5.3.8 Charges for Fixing of storage water job 715
03638 heater including four
nos. rag bolts of suitable size,supply &
making heavy gauge inlet, outlet C.P.
connection, testing, carrying from
store to site,etc. as required
5.4 PUMPSETS

SINGLE PHASE SUBMERSIBLE MOTOR PUMP


SETS
213 ELEC-5.4.1 Supply and Transportation of ………..,5star rated submersible motor
pumpset, confirming to IS 8034 and motor confirming to IS 9283 with
water proof winding,Pump shall be suitable for various delivery head and
discharge with stainless steel shaft.Motor suitable for working on 240V ±
10% , SinglePhase 50 Hz AC supply,etc complete for 4" Bore well.
Makes : As per list of recommended brands as category I.
MAT- a 0.75HP 8 Stage 1 No 15565
03639
MAT- b 1.00HP 10 Stage 1 No 17820
03640
MAT- c 1.00HP 15 Stage 1 No 18370
03641
MAT- d 1.50HP 21 Stage 1 No 22275
03642
MAT- e 2.00HP 25 Stage 1 No 26730
03643
f

214 ELEC-5.4.2 Supply and Transportation of ………..,5star rated submersible motor


pumpset, confirming to IS 8034 and motor confirming to IS 9283 with
water proof winding,Pump shall be suitable for various delivery head and
discharge with stainless steel shaft.Motor suitable for working on 240V ±
10% , SinglePhase 50 Hz AC supply,etc complete for 4" Bore well.
Makes : As per list of recommended brands as category II.

MAT- a 0.75HP 8 Stage 1 No 13970


03644
MAT- b 1.00HP 10 Stage 1 No 15950
03645
MAT- c 1.00HP 15 Stage 1 No 16500
03646
MAT- d 1.50HP 21 Stage 1 No 20020
03647
MAT- e 2.00HP 25 Stage 1 No 24035
03648

79
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

THREE PHASE SUBMERSIBLE MOTOR PUMP


SETS.
215 ELEC-5.4.3 Supply and Transportation of ………..,5star rated submersible motor
pumpset, confirming to IS 8034 and motor confirming to IS 9283 with
water proof winding,Pump shall be suitable for various delivery head and
discharge with stainless steel shaft.Motor suitable for working on 415V ±
10% , Three Phase 50 Hz AC supply,etc complete for 4" Bore well.
Makes : As per list of recommended brands as category I.
MAT- a 3.00HP 15Stage 1 No 21670
03649
MAT- b 4.00HP 20Stage 1 No 25300
03650
MAT- c 5.00HP 25Stage 1 No 29920
03651
216 ELEC-5.4.4 Supply and Transportation of ………..,5star rated submersible motor
pumpset, confirming to IS 8034 and motor confirming to IS 9283 with
water proof winding,Pump shall be suitable for various delivery head and
discharge with stainless steel shaft.Motor suitable for working on 415V ±
10% , Three Phase 50 Hz AC supply,etc complete for 4" Bore well.
Makes : As per list of recommended brands as category II.

MAT- a 3.00HP 15Stage 1 No 20350


03652
MAT- b 4.00HP 20Stage 1 No 23760
03653
MAT- c 5.00HP 25Stage 1 No 28160
03654
217 ELEC-5.4.5 Supply and Transportation of ………..,5star rated submersible motor
pumpset, confirming to IS 8034 and motor confirming to IS 9283 with
water proof winding,Pump shall be suitable for various delivery head and
discharge with stainless steel shaft.Motor suitable for working on 415V ±
10% , Three Phase 50 Hz AC supply,etc complete for 6" Bore well.
Makes : As per list of recommended brands as category I.

MAT- a 3.00HP 5-10 Stage 1 No 33000


03655
MAT- b 5.00HP, 5-10Stage 1 No 37125
03656
MAT- c 5.00HP, 12-16 Stage 1 No 42350
03657
MAT- d 7.50HP, 5-10 Stage 1 No 41690
03658
MAT- e 7.50HP, 12-16 Stage 1 No 46200
03659
MAT- f 7.50HP, 20-24 Stage 1 No 47300
03660

80
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- g 10HP, 5-10 Stage 1 No 48950


03661
MAT- h 10HP, 12-16 Stage 1 No 50600
03662
MAT- i 10HP, 20-24 Stage 1 No 57200
03663
MAT- j 12.5HP, 8-12 Stage 1 No 50600
03664
MAT- k 12.5HP, 16-24 Stage 1 No 59400
03665
MAT- l 15HP, 8-12 Stage 1 No 63690
03666
MAT- m 15HP, 16-24 Stage 1 No 65780
03667
MAT- n 20HP 10-20 Stage 1 No 76450
03668
MAT- o 20HP 30-40 Stage 1 No 79750
03669
MAT- p 25HP 20-25 Stage 1 No 86900
05510
218 ELEC-5.4.6 Supply and Transportation of ………..,5star rated submersible motor
pumpset, confirming to IS 8034 and motor confirming to IS 9283 with
water proof winding,Pump shall be suitable for various delivery head and
discharge with stainless steel shaft.Motor suitable for working on 415V ±
10% , Three Phase 50 Hz AC supply,etc complete for 6" Bore well.
Makes : As per list of recommended brands as category II.

MAT- a 3.00HP 5-10 Stage 1 No 29700


03670
MAT- b 5.00HP, 5-10Stage 1 No 33330
03671
MAT- c 5.00HP, 12-16 Stage 1 No 38115
03672
MAT- d 7.50HP, 5-10 Stage 1 No 37510
03673
MAT- e 7.50HP, 12-16 Stage 1 No 41580
03674
MAT- f 7.50HP, 20-24 Stage 1 No 42570
03675
MAT- g 10HP, 5-10 Stage 1 No 44000
03676
MAT- h 10HP, 12-16 Stage 1 No 45650
03677
MAT- i 10HP, 20-24 Stage 1 No 51480
03678

81
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- j 12.5HP, 8-12 Stage 1 No 45650


03679
MAT- k 12.5HP, 16-24 Stage 1 No 53460
03680
MAT- l 15HP, 8-12 Stage 1 No 57310
03681
MAT- m 15HP, 16-24 Stage 1 No 59180
03682
MAT- n 20HP 10-20 Stage 1 No 68750
03683
MAT- o 20HP 30-40 Stage 1 No 71720
03684
SINGLE PHASE OPEN WELL SUBMERSIBLE MOTOR PUMP SETS

219 ELEC-5.4.7 Supply and Transportation of ……...Single phase open well submersible
motor pumpset confirms to IS 14220 : 1994.
Makes : As per list of recommended brands as category I.
MAT- a 1.00HP 1 No 12320
03685
MAT- b 1.50HP 1 No 13860
03686
MAT- c 3.00HP 1 No 18920
03687
220 ELEC-5.4.8 Supply and Transportation of ……...Single phase open well ISI
submersible motor pumpsetconfirms to IS 14220 : 1994.
Makes : As per list of recommended brands as category II.
MAT- a 1.00HP 1 No 11550
03688
MAT- b 1.50HP 1 No 13200
03689
MAT- c 3.00HP 1 No 17985
03690
THREE PHASE OPEN WELL SUBMERSIBLE PUMP
SETS
221 ELEC-5.4.9 Supply and Transportation of ……... Three phase open well ISI
submersible motor pumpset confirms to IS 14220 : 1994. .
Makes : As per list of recommended brands as category I.
MAT- a 3.00HP(65x50) 1 No 18920
03691
MAT- b 5.00HP(75x65) 1 No 23650
03692
MAT- c 7.50HP(100x75) 1 No 28050
03693
MAT- d 10.00HP(100x75) 1 No 35750

82
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03694

222 ELEC-5.4.10 Supply and Transportation of ……... Three phase open well ISI
submersible motor pumpset confirms to IS 14220 : 1994.
Makes : As per list of recommended brands as category II. .

MAT- a 3.00HP(65x50) 1 No 18150


03695
MAT- b 5.00HP(75x65) 1 No 22220
03696
MAT- c 7.50HP(100x75) 1 No 26400
03697
MAT- d 10.00HP(100x75) 1 No 34100
03698
SINGLE PHASE MONO BLOCK MOTOR PUMP
SETS.
223 ELEC-5.4.11 Supply and Transportation of ……. Single phase Mono block CI body
motor pumpset confirms to IS 9079:2002
Makes : As per list of recommended brands as category I.

MAT- a 0.5HP(25x25mm) 1 No 5500


03699
MAT- b 1.0HP (25x25mm) 1 No 7865
03700
MAT- c 1.5HP(32x25mm) 1 No 10560
03701
224 ELEC-5.4.12 Supply and Transportation of ……. Single phase Mono block CI body
motor pumpset confirms to IS 9079:2002
Makes : As per list of recommended brands as category II.
MAT- a 0.5HP(25x25mm) 1 No 5170
03702
MAT- b 1.0HP (25x25mm) 1 No 7480
03703
MAT- c 1.5HP(32x25mm) 1 No 10065
03704
225 ELEC-5.4.13 Supply and Transportation of………. Three phase ISI self priming Mono
block IP44 motor pumpset .
Makes : As per list of recommended brands as category I.
MAT- a 2.00HP(40x40mm) 1 No 15620
03705
MAT- b 3.0HP (50x50mm) 1 No 21120
03706
MAT- c 5.00HP(80x80mm) 1 No 25520
03707
226 ELEC-5.4.14 Supply and Transportation of………. Three phase ISI self priming Mono
block IP44 motor pumpset .

83
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Makes : As per list of recommended brands as category II.

MAT- a 2.00HP(40x40mm) 1 No 14850


03708
MAT- b 3.0HP (50x50mm) 1 No 20130
03709
MAT- c 5.00HP(80x80mm) 1 No 24420
03710
CONTROL PANEL BOARD FOR MOTOR
PUMPSETS
227 MAT- ELEC-5.4.15 Fabrication , transportation and 1 No 4950
03711 supply of suitable size panel board
for single phase submersible motor
up to 1.5 HP consisting of relay,
Contactor, starting and running
capacitors, Voltmeter, Ammeter,
indicator lamps, MCB , on/off switch
including supply and fixing of DOL
starter.of complete.,
Makes : As per list of recommended
brands.
228 MAT- ELEC-5.4.16 Fabrication , transportation and 1 No 6600
03712 supply of suitable size panel board
for single phase submersible motor 2
to 3HP consisting of relay,
Contactor, starting and running
capacitors, Voltmeter, Ammeter,
indicator lamps, MCB , on/off switch
including supply and fixing of DOL
starter of complete.,.
Makes : As per list of recommended
brands.
229 ELEC-5.4.17 Fabrication ,transportationand and supply of wall mounted control panel
board of size 600x600x250mm made of 18 SWG CRCA sheet steel
enclosure, 14 SWG mounting plate for cable entry fabricated , painted
with two coats of Red oxide primer and two coats of Grey paint, lock and
key arrangements two side lovures with weld mesh inside etc., complete
consisting of the following equipment with all internal wiring using L&T /
Finolex copper FRLS cables of suitable size and capacity and cable
clamp etc complete for 3 phase motor pump sets.
Makes : As per list of recommended brands .
Voltmeter ; 0-500 V 96x96mm size.
0 to 20 Amps / 0 50 Amps Ammeter (96x96mm size)-1No.

Single phase preventor of suitable range - 1No.

32 A TP, 10KA MCB. - 1No

Indication lamps (R-Y-B) with switch control - 1set

84
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Voltmeter & Ammeter selector switch - 2 Nos

Supply and fixing of ISI Mark suitable capacitor


230 MAT- a Upto 7.5 HP with DOL Starter of. 1 No 8800
03713
231 MAT- b above 7.5 HP to 12.5 HP with Star- 1 No 15400
03714 Delta Starter
232 MAT- c From 15 HP up to 20 HP 1 No 20350
03715 with Automatic Star Delta Starter

233 ELEC-5.4.18 Supply & Fixing of D.O.L Starter 250V, Single phase, 50Hz. With SS
enclouser comprising of contactor with bi-metalic relay with necessary
push buttons, etc., complete suitable for…...
Makes : As per list of recommended brands.
MAT- a up to 3 HP 1 No 1045
03716

234 ELEC-5.4.19 Supply & Fixing of D.O.L Starter 415V, 3 phase, 50Hz..enclosed with no
volt coil and overload protection with necessary materials, etc., complete
suitable for…...
Makes : As per list of recommended brands.
MAT- a up to 3 HP 1 No 1870
03717
MAT- b 5 to 7.5 HP 1 No 2090
03718
MAT- c 10 HP 1 No 2310
03719
235 ELEC-5.4.20 Supply & Fixing of Star-Delta Starter 415V, 3 phase, 50Hz.. enclosed
with no volt coil, overload protection and single phase preventor , etc.,
complete suitable for
Makes : As per list of recommended brands.
MAT- a 12.50 to 15HP. 1 No 7480
03720
MAT- b 25HP to 30HP 1 No 12342
03721
UPVC PIPES AND FITTINGS

236 ELEC-5.4.21 Supply and delivery of ................. for submersible motors with both ends
square threaded, with rubber 'O' rings with smooth inner surface which
can take the minimum load of 2100 to 4000 Kgs weights.
Makes : As per list of recommended brands.
MAT- a 42 / 32mm dia UPVC raising column 1RM 143
03722 pipe, with standing upto 20 Kgs /
CM2 upto 200 Mts
MAT- b 48 / 40mm UPVC pipe with standing 1RM 176
03723 upto 20 Kgs / CM2 upto 200 Mts

85
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 60/50 mm UPVC pipe with standing 1RM 253


03724 upto 20 Kgs / CM2 upto 200 Mts
MAT- d 75/65 mm UPVC pipe with standing 1RM 341
03725 upto 20 Kgs / CM2 upto 200 Mts
MAT- e 88/80 mm UPVC pipe with standing 1RM 490
03726 upto 20 Kgs / CM2 upto 200 Mts
237 MAT- ELEC-5.4.22 Supply and delivery of heavy duty 1NO 44
03727 couplings 42/32 mm UPVC pipe (27
Kgs / CM 2 ) capable of with standing
up to 27 Kgs / CM2 above 200 mts
and upto 300 mts
238 MAT- ELEC-5.4.23 Supply and delivery of heavy duty 1NO 61
03728 couplings 48/40 mm UPVC pipe (27
Kgs / CM 2 ) capable of with standing
up to 27 Kgs / CM2 above 200 mts
and upto 300 mts
239 MAT- ELEC-5.4.24 Supply and delivery of heavy duty 1NO 66
03729 couplings 60/50 mm UPVC pipe (27
Kgs / CM 2 ) capable of with standing
up to 27 Kgs / CM2 above 200 mts
and upto 300 mts
240 MAT- ELEC-5.4.25 Supply and delivery off heavy duty 1NO 77
03730 couplings 75/65 mm UPVC pipe (27
Kgs / CM 2 ) capable of with standing
up to 27 Kgs / CM2 above 200 mts
and upto 300 mts
241 MAT- ELEC-5.4.26 Supply and delivery of heavy duty 1NO 88
03731 couplings 88/80 mm UPVC pipe (27
Kgs / CM 2 ) capable of with standing
up to 27 Kgs / CM2 above 200 mts
and upto 300 mts
242 ELEC-5.4.27 Supply and Delivery of CI Adopter Assembly
Makes : As per list of recommended brands.

MAT- a 1/2" (48/40mm) 1NO 633


03732
MAT- b 2" (60/50mm) 1NO 836
03733
MAT- c 2 1/2" (75/65 mm) 1NO 1078
03734
243 ELEC-5.4.28 Supply and Delivery of pump guard assembly with 2Nos SS Powder
coated flange and 2Nos SS Rods with nut and colter pin.
Makes : As per list of recommended brands.

MAT- a 1 1/2" (48/40mm) 1NO 396


03735
MAT- b 2" (60/50mm) 1NO 440
03736

86
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 2 1/2" (75/65 mm) 1NO 605


03737
MAT- d 3"(88/80 mm) 1NO 880
03738
5.5 AIR CONDITIONERS

244 ELEC-5.5.1 Supply of ..............split AC unit with high wall mounted indoor unit and
outdoor condencing unit Hermetically sealed compressor suitable for
operation on 230V, 50Hz, 1Phase AC supply capable of performing
cooling dehumidifying air circulating and filtering with cooling and
condensing units with 3 mts of copper piping, insulation kit and 4 mts of
3 core copper flexible cable including cordless remote control etc.
1.5TR Split ACs

MAT- a 1.5 TR 3 Star capable of delivering 1 No 51175


03743 18000 BTU/hr and above with
operating on refrigerant R-32/ R-
410A.
Makes : As per list of recommended
brands as category I.
MAT- b 1.5 TR 3 Star capable of delivering 1 No 47725
03744 18000 BTU / hr and above with
operating on refrigerant R-32 / R-
410A
Makes : As per list of recommended
brands as category II.
2.0 TR Split ACs

MAT- c 2.0 TR 3 Star capable of delivering 1 No 59225


03747 24000 BTU/ hr and above with
operating on refrigerant R-32 / R-
410A.
Makes : As per list of recommended
brands as category I.
MAT- d 2.0 TR 3 Star capable of delivering 1 No 52325
03748 24000 BTU/ hr and above with
operating on refrigerant R-32 / R-
410A.
Makes : As per list of recommended
brands as category II.
Inverter Split AC Unts (Cooling
Only)
245 ELEC-5.5.2 Supply of ...............INVERTER Model Cool type split AC unit with high
wall mounted Single Split indoor unit and outdoor condencing unit
Hermetically sealed compressor suitable for operation on 230V, 50Hz,
1Phase AC supply capable of performing Heat cool dehumidifying air
circulating and filtering with cooling and condensing units with 3 mts of
copper piping, insulation kit and 4 mts of 4 core copper flexible chord
with cordless remote control etc., dual barrier coating in order to protect
coil form oxidigation.
0.8/ 1.0TR Split ACs

87
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- a 0.8 TR 5 Star capable of delivering 9600 BTU/hr 39675


05511 and above with operating on refrigerant R-32/ R-410A.
Makes : As per list of recommended brands as
category I.
MAT- b 0.8 TR 5 Star capable of delivering 9600 BTU/hr 33925
05512 and above with operating on refrigerant R-32/ R-410A
Makes : As per list of recommended brands as
category II.
MAT- c 1.0 TR 5 Star capable of delivering 12000 BTU/hr 44275
05513 and above with operating on refrigerant R-32/ R-410A
Makes : As per list of recommended brands as
category I.
MAT- d 1.0 TR 5 Star capable of delivering 12000 BTU/hr 38525
05514 and above with operating on refrigerant R-32/ R-410A
Makes : As per list of recommended brands as
category II.
1.5, 1.8 & 2.0TR Split ACs

MAT- e 1.5 TR 5 star capable of delivering 1 No 55775


03753 18000 BTU/hr and above with
operating on refrigerant R-32/ R-
410A, COP not less than 4.5
Makes : As per list of recommended
brands as category I.
MAT- f 1.5 TR 5 star capable of delivering 1 No 53475
03754 18000 BTU/hr and above with
operating on refrigerant R-32/ R-
410A,COP not less than 4.5
Makes : As per list of recommended
brands as category II.
MAT- g 1.8/1.9TR 5star capable of delivering 1 No 65550
05515 24000 BTU/hr and above with
operating on refrigerant R-410A / R-
32
Makes : As per list of recommended
brands as category I.
MAT- h 1.8/1.9 TR 5 Star capable of 1 No 62100
05516 delivering 24000 BTU/hr and above
with operating on refrigerant R-410A /
R-32
Makes : As per list of recommended
brands as category II.
MAT- i 2.0/2.2 TR 5 star capable of 1 No 76475
03757 delivering 24000 BTU/hr and above
with operating on refrigerant R-410A /
R-32
Makes : As per list of recommended
brands as category I.
MAT- j 2.0 TR 5 Star capable of delivering 1 No 67850
03758 24000 BTU/hr and above with
operating on refrigerant R-410A / R-
32
Makes : As per list of recommended

88
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

brands as category II.

INVERTER CASSETTE TYPE AC


UNITS
246 ELEC-5.5.35 Supply of .......... inverter Cassette type AC unit with ceiling mounted
indoor unit and outdoor condencing unit Hermetically sealed
compressor suitable for operation on AC supply capable of performing
cooling dehumidifying air circulating and filtering with cooling and
condensing units etc. complete with Wireless remote controller, without
refrigerent piping and cable.
MAT- a 1.5 TR 4 star Single Phase capable of 1 No 83950
03759 delivering 18000 BTU / hr and above
with operating on refrigerant R-32 / R-
410A.
Makes : As per list of recommended
brands as category I.
MAT- b 2.0TR 4 star Single Phase capable 1 No 89700
03760 of delivering 24000 BTU / hr and
above with operating on refrigerant R-
32 / R-410A, .
Makes : As per list of recommended
brands as category I.
MAT- c 2.0TR 4 star Single Phase capable 1 No 86250
03761 of delivering 24000 BTU / hr and
above with operating on refrigerant R-
32 / R-410A.
Makes : As per list of recommended
brands as category II.
MAT- d 3.5 TR 4 star Three Phase capable of 1 No 158700
03762 delivering 42000 BTU / hr and above
with operating on refrigerant R-32 / R-
410A.
Makes : As per list of recommended
brands as category I.
MAT- e 3.5 TR 4 star Three Phase capable of 1 No 155825
03763 delivering 42000 BTU / hr and above
with operating on refrigerant R-32 / R-
410A.
Makes : As per list of recommended
brands as category II.
MAT- f 4.0 TR 4 star Three Phase capable of 1 No 163300
03764 delivering 48000 BTU / hr and above
with operating on refrigerant R-32 / R-
410A.
Makes : As per list of recommended
brands as category I.
MAT- g 4.0 TR 4 star Three Phase capable 1 No 148350
03765 of delivering 48000 BTU / hr and
above with operating on refrigerant R-
32 / R-410A.
Makes : As per list of recommended

89
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

brands as category II.

TOWER MODEL (Vertical) TYPE AC


UNITS
247 ELEC-5.5.36 Supply of Slim line / Tower Model/Verticool type ..........split AC unit
with indoor unit and floor mounted outdoor condencing unit with 3.5 mtr
of Copper piping,insulation kit and 4 mtr of 4 core copper flexible card
with refrigerant 410A/R32, Hermetically sealed Scroll compressor
suitable for operation on AC supply capable of performing cooling
dehumidifying air circulating and filtering with cooling and condensing
units etc complete with cordless remote control
MAT- a 3.0/ 3.3TR Three Phase capable of 1 No 104650
03766 delivering 39600 BTU/hr and above
woth operating on refrigerant R-32/R-
410.Makes : As per list of
recommended brands.
MAT- b 3.8 /4.0TR Three Phase capable of 1 No 110975
03767 delivering 45600BTU/hr and above
woth operating on refrigerant R-32/R-
410.
Makes : As per list of recommended
brands.

MAT- c 4.5/ 4.6TR Three Phase capable of 1 No 120750


03768 delivering 55200 BTU/hr and above
woth operating on refrigerant R-32/R-
410.
Makes : As per list of recommended
brands.
HVAC SYSTEMS(VRV/VRF)

248 ELEC-5.6.1 Supply of Air cooled VRV / VRF Air Conditioning system of having high
COP complete with indoor and outdoor units duly charged with refrigerant
R-410A and oil (first charge) suitable for cooling with individual controller,
(suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and
complete with all accessories, fittings etc. The units shall be BMS
Compatible.
Outdoor Units shall be fully inverter system complete with 100%
scroll/rotary compressor and drive arrangement, initial charge of
refrigerant (R-410A),refrigerant piping, drier, sight glass, dual
pressure cutout all housed and supported properly in cabinet, air cooled
condenser & its controller for following capacities. The VRV system shall
be cooling only system. Makes : As per list of recommended brands as
category I.
Type of Compressor : Hermitic sealed Inverter Scroll/Twin Rotary

ODU should delvier the required capacity at the ambient conditions of the
place as per ISHRAE Standards.

90
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

The System should be highly energy efficient and COP shall not be less
than 3.7. The outdoor units shall be suitable for operation between 5 and
53 deg C in cooling mode.

MAT- a 6 HP 1 No 166750
03769
MAT- b 8 HP 1 No 181700
03770
MAT- c 10 HP 1 No 225400
03771
MAT- d 12 HP 1 No 253000
03772
MAT- e 14 HP 1 No 286350
03773
MAT- f 16 HP 1 No 326600
03774
MAT- g 18 HP 1 No 358800
03775
MAT- h 20 HP 1 No 394450
03776
ELEC-5.6.2 Supply of Air cooled VRV / VRF Air Conditioning system of having high
COP complete with indoor and outdoor units duly charged with refrigerant
R-410A and oil (first charge) suitable for cooling with individual controller,
(suitable for 415 +/- 10% for outdoor and 230 +/- 5% for indoor units) and
complete with all accessories, fittings etc. The units shall be BMS
Compatible.
Outdoor Units shall be fully inverter system complete with 100%
scroll/rotary compressor and drive arrangement, initial charge of
refrigerant (R-410A),refrigerant piping, drier, sight glass, dual
pressure cutout all housed and supported properly in cabinet, air cooled
condenser & its controller for following capacities. The VRV system shall
be cooling only system.
Makes : As per list of recommended brands as category II.
Type of Compressor : Hermitic sealed Inverter Scroll/Twin Rotary

ODU should delvier the required capacity at the ambient conditions of the
place as per ISHRAE Standards.
The System should be highly energy efficient and COP shall not be less
than 3.7. The outdoor units shall be suitable for operation between 5 and
53 deg C in cooling mode.

MAT- a 6 HP 1 No 153525
05517
MAT- b 8 HP 1 No 166750
05518

91
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- c 10 HP 1 No 207345
05519
MAT- d 12 HP 1 No 232760
05520
MAT- e 14 HP 1 No 263350
05521
MAT- f 16 HP 1 No 300150
05522
MAT- g 18 HP 1 No 330050
05523
MAT- h 20 HP 1 No 362250
05524
MAT- ELEC-5.6.3 Supply and Installation of Ref Nets 1 No 5520
03777 for Double ODU connections

250 MAT- ELEC-5.6.4 Supply and Installation of Ref Nets 1 No 10580


03778 for Triple ODU connections

251 MAT- ELEC-5.6.5 Supply and Installation of Multi 1 No 4830


03779 Connection Joint / Ref Nets for IDUs

252 ELEC-5.6.6 Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower
section and drive arrangement, initial charge of refrigerant & oil, integral
refrigerant piping, electronic expansion valve, electrical panel with
controls and duly wired, thermostatic control.
Makes : As per list of recommended brands as category I.
Type Of Units :Hi Wall type units

MAT- a 1.0 TR 1 No 31625


03780
MAT- b 1.6 TR 1 No 34500
03781
MAT- c 2.0 TR 1 No 35650
03782
ELEC-5.6.7 Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower
section and drive arrangement, initial charge of refrigerant & oil, integral
refrigerant piping, electronic expansion valve, electrical panel with
controls and duly wired, thermostatic control.
Makes : As per list of recommended brands as category II.
Type Of Units :Hi Wall type units 1 No

MAT- a 1.0 TR 1 No 31740


05525
MAT- b 1.6 TR 1 No 32775
05526
MAT- c 2.0 TR 1 No 32775
05527

92
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
253 ELEC-5.6.8 Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower
section and drive arrangement, initial charge of refrigerant & oil, integral
refrigerant piping, electronic expansion valve, electrical panel with
controls and duly wired, thermostatic control.
Makes : As per list of recommended brands as category I.

Type Of Units :Roundflow/4 way


Cassette units
MAT- a 1.0 TR 1 No 42090
03783
MAT- b 1.5/1.6 TR 1 No 47150
03784
MAT- c 2.0 TR 1 No 48300
03785
MAT- d 2.6 TR 1 No 52900
03786
MAT- e 3.2 TR 1 No 54050
03787

MAT- f 4.0 TR 1 No 55200


03788
MAT- g 4.5 TR 1 No 57845
03789
ELEC-5.6.9 Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower
section and drive arrangement, initial charge of refrigerant & oil, integral
refrigerant piping, electronic expansion valve, electrical panel with
controls and duly wired, thermostatic control.
Makes : As per list of recommended brands as category II.

Type Of Units :Roundflow/4 way


Cassette units
MAT- a 1.0 TR 1 No 38640
05528
MAT- b 1.5/1.6 TR 1 No 43355
05529
MAT- c 2.0 TR 1 No 44390
05530
MAT- d 2.6 TR 1 No 48645
05531
MAT- e 3.2 TR 1 No 49680
05532
MAT- f 4.0 TR 1 No 50600
05533
MAT- g 4.5 TR 1 No 53130

93
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

05534
254 ELEC-5.6.10 Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower
section and drive arrangement, initial charge of refrigerant & oil, integral
refrigerant piping, electronic expansion valve, electrical panel with
controls and duly wired, thermostatic control.
Makes : As per list of recommended brands as category I.
Type Of Units :High Static Duct
Units
MAT- a 3.2 TR 1 No 57845
03790
MAT- b 4.0 TR 1 No 60720
03791
MAT- c 4.5 TR 1 No 71875
03792
MAT- d 5.5 TR 1 No 96830
03793
MAT- e 6.3 TR 1 No 102005
03794
MAT- f 8.0 TR 1 No 107525
03795
ELEC-5.6.11 Supply of Indoor Units consisting of 2/3/4 row deep DX coil, filter, blower
section and drive arrangement, initial charge of refrigerant & oil, integral
refrigerant piping, electronic expansion valve, electrical panel with
controls and duly wired, thermostatic control.
Makes : As per list of recommended brands as category II.
Type Of Units :High Static Duct
Units
MAT- a 3.2 TR 1 No 52900
05535
MAT- b 4.0 TR 1 No 55200
05536
MAT- c 4.5 TR 1 No 66125
05537
MAT- d 5.5 TR 1 No 88550
05538
MAT- e 6.3 TR 1 No 93150
05539
MAT- f 8.0 TR 1 No 98900
05540
255 MAT- ELEC-5.6.12 Supply, Installation, Testing & Commissioning Simple 1610
03796 wireless remote contoller to control the IDUs with
Machine coding, ON-OFF & Temp. setting of
individual IDU and group of IDU.

94
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
256 ELEC-5.6.13 Supply of Indoor Units consisting of 3/4 row deep DX coil, drain pan,
filter, blower section and drive arrangement, initial charge of refrigerant &
oil, integral refrigerant piping, electronic expansion valve, electrical panel
with controls, duly wired, thermostatic control corded/cordless remote
controller supports for indoor units etc.
Makes : As per list of recommended brands as category I.
Type of Units : Ductable TFA Units

MAT- a 4TR 1 No 95048


03797
MAT- b 6TR 1 No 114540
03798
MAT- c 8TR 1 No 120750
03799
ELEC-5.6.14 Supply of Indoor Units consisting of 3/4 row deep DX coil, drain pan,
filter, blower section and drive arrangement, initial charge of refrigerant &
oil, integral refrigerant piping, electronic expansion valve, electrical panel
with controls, duly wired, thermostatic control corded/cordless remote
controller supports for indoor units etc.
Makes : As per list of recommended brands as category II.
Type of Units : Ductable TFA Units

MAT- a 4TR 1 No 87400


05541
MAT- b 6TR 1 No 104650
05542
MAT- c 8TR 1 No 110975
05543
HVAC-LOW SIDE WORKS

257 ELEC-5.6.15 Lifting, shifting, positioning, Installation and testing of the ODUs including
all accessories with Vibration Isolators for ODUs etc., complete

MAT- a 6 to 8 HP 1 No 8050
03800
MAT- b 10 to 12 HP 1 No 11500
03801
MAT- c 14 to 20 HP 1 No 13800
03802
258 ELEC-5.6.16 Lifting Shifting, Positioning ,Installation Testing and commissioning of
the following indoor units with including all required accessoires etc
complete.,

Type Of Units :Hi Wall Units 1 No

MAT- a 1.0 TR to 2.0 TR 1 No 1380


03803

95
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
259 ELEC-5.6.17 Lifting Shifting, Positioning ,Installation Testing and commissioning of
the following indoor units with including all required accessoires etc
complete.,

Type Of Units :Round Flow /4 way


Cassette units
MAT- a 1.0 TR to 2.0 TR 1 No 1725
03804
MAT- b 2.6 TR to 4.5 TR 1 No 2875
03805
260 ELEC-5.6.18 Lifting Shifting, Positioning ,Installation Testing and commissioning of
the following indoor units with including all required accessoires etc
complete.,

Type Of Units :High Static Duct


Units
MAT- a 3.2 TR to 4.5 TR 1 No 3450
03806
MAT- b 5.5 TR to 8.0 TR 1 No 5175
03807
261 ELEC-5.6.19 Installation, testing & commissioning of Indoor Units consisting of 2/3/4
row deep DX coil, filter, blower section and drive arrangement, initial
charge of refrigerant & oil, integral refrigerant piping, electronic expansion
valve, electrical panel with controls duly wired, thermostatic control
corded/cordless remote controller supports for indoor units etc.

Type of Units : Ductable TFA Units

MAT- a 4 TR to 8 TR 1 No 5175
03808

Refrigerant Piping

262 ELEC-5.6.20 Supply, installation and testing of Refrigerant Piping consisting of Copper
tubes of wall thickness 20G/22G inclusive of Suction Gas Piping &
Fittings,Liqid Line Piping & Fittings, with class "O" nitrile rubber
Insulation with finish as required.The piping to be mounted & supported
properly with suitable size of clamp,M.S. hanger, tray etc., as required at
site Makes : As per list of recommended brands.

The insulation shall be closed cell/cross linked elastomeric Nitrile rubber


of thickness 13/19 mm.
The insulation thickness upto 19.1 mm dia pipe shall be 13 mm and
above 19.1 mm dia, the insulation thickness shall be 19 mm.

Testing of refrigerant piping and procedure shall be done as per


Manufacturer's recommendations

MAT- a 34.9 mm dia Rmt 1323


03809
MAT- b 28.6 mm dia Rmt 1208

96
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03810
MAT- c 22.2 mm dia Rmt 1093
03811
MAT- d 19.1 mm dia Rmt 978
03812
MAT- e 15.9 mm dia Rmt 863
03813
MAT- f 12.7 mm dia Rmt 748
03814
MAT- g 9.5 mm dia Rmt 552
03815
MAT- h 6.4 mm dia Rmt 483
03816
263 ELEC-5.6.21 Supply, installation and testing of UPVC Drain Piping with 6mm Nitrile
Rubber class "O" Insulation covered with interwoven glass cloth
protection. Necessary pipe fittings(Including enlarger, bends, T
Joints etc) has to be considered to connect the UPVC drain pipe to
cast iron floor trap.
MAT- a 25 mm dia Rmt 173
03817
MAT- b 32 mm dia Rmt 207
03818
MAT- c 40mm dia Rmt 253
03819
MAT- d 50 mm dia Rmt 299
03820
Supply of PVC insulated 2 core 1.5 Rmt
Sqmm sheathed flexible copper cable
for voltage up to 1100V as per IS
694/1990. ( Covered in Section -1)
264 MAT- ELEC-5.6.22 Supply and transportation of R 410A kg 1208
03821 Gas for the system.

265 MAT- ELEC-5.6.23 Providing Pressure testing of entire HP 1438


03822 system with Nitrogen and vaccuming
nitrogen for all indoor and outdoor
units. The pressure testing shall be
done as per OEM recommendation.
266 MAT- ELEC-5.6.24 Supply, installation, testing No 85100
03823 &commissioning of Stand alone,
intelligent Touch controller with
Display for controlling the indoor &
outdoor units from a Remote place for
all the circuits.

97
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
267 ELEC-5.6.25 Supply, installation, testing& commissioning of GSS Ducting with
required angle flanges & installation materials such as heavy duty
supports by anchor fasteners etc as required asper IS 655 /SMACNA
Standards.Makes : As per list of recommended brands.
MAT- a 24 G sqm 949
03824
MAT- b 22 G sqm 1064
03825
MAT- c 20 G sqm 1265
03826
MAT- d 18 G sqm 1380
03827
Thermal Insulation

268 MAT- ELEC-5.6.26 Supply &Fixing of Duct Thermal Insulation applied outside of the
03828 duct work with All. backed Closed cell nitrile/ Cross linked foam duly
fixed with adhesive and tapes.

13 mm Thick sqm 667

Accoustic Insulation

269 ELEC-5.6.27 Supply & Fixing of Duct Accoustic Insulation applied inside of the duct
work with All. backed Open cell nitrile duly fixed with adhesive and tapes

MAT- a 10/15 mm Thick sqm 1035


03829
270 MAT- ELEC-5.6.28 Supply, Installation, Testing and sqm 9775
03830 commissioning of extruded Aluminum
powder coated grills/ diffusers for
supply with removable core type with
collar damper
271 MAT- ELEC-5.6.29 Supply, Installation, Testing and sqm 7130
03831 commissioning of extruded Aluminum
powder coated grills/ diffusers for
retrun with removable core type
without collar damper
272 MAT- ELEC-5.6.30 Supply , Erection and Testing of GI sqm 6210
03832 Opposed blade Volume control
dampers made out of 18G frame and
20G blades
273 MAT- ELEC-5.6.31 Supply , Erection of Fresh air louver sqm 4945
03833 with extruded aluminium grill with SS
wire mesh and GI volume control
damper with 20 micron filters
274 MAT- ELEC-5.6.32 Supply and Installation of Underdeck sqm 748
03834 Insulation with 50 mm thk EPS, 48
Kg/Cum density, factory laminated
faced alumimun foil coreved with GI
cross wiring.

98
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
275 MAT- ELEC-5.6.33 Supply and Installation of GI Fusible sqm 7475
03835 link Fire dampers 500 mm long with
sleeve as per UL 555
Standard,Minimum width of damper
shall be 225 mm.
276 MAT- ELEC-5.6.34 Supply and Installation of GI backdraft sqm 6210
03836 dampers as per UL 555 Standard,

277 MAT- ELEC-5.6.35 Supply, installation and testing of each 2530


03837 Canvas connection for the Treated
Fresh Air units to the duct
5.7 EVAPORATIVE AIR COOLING
SYSTEM
278 MAT- ELEC-5.7.1 Supply of single phase evaporative air 1 No 120750
03838 cooling unit with a capacity of 9000
CFM consisting cabinet and water
tank made of polypropylenematerial,
blower water pump of 40W, single
phase 1.20 KW motor axial type fan
with variable speed, 20 micron
filteration, noise levelless than 78 dBA
with auto cleaning,humidity control
and water lack protection
etccomplete.
Makes : As per list of recommended
brands.
279 MAT- ELEC-5.7.2 Supply of Three phase evaporative air 1 No 207000
03839 cooling unit with a capacity of 12000 -
15000 CFM consisting cabinet and
water tank made of polypropylene
material, blower water pump of 40W,
Three phase 3.0 KW motor axial type
fan with 2 speed, 20 micron filteration,
noise level less than 78 dBA with auto
cleaning and water lack protection etc
complete.
Makes : As per list of recommended
brands.
280 MAT- ELEC-5.7.3 Supply and fixing of 13mm thick Nitrile 1 sft 63
03840 insulation for out door unit.

281 MAT- ELEC-5.7.4 Supply and fixing of 50mm thick 1 sft 67


03841 glasswool of 24 kg density with
alluminium foil insulation for indoor
duct.
282 MAT- ELEC-5.7.5 Supply and fixing of angular iron 1 No 5750
03842 frame with 2 coats of zincromat red
oxide for installation of air cooling unit
283 MAT- ELEC-5.7.6 Installation and commissioning 1 No 4140
03843 charges for air cooling unit

5.8 STABILIZERS

99
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
284 ELEC-5.8.1 Supplly of ………... Stabilizer.
Makes : As per list of recommended brands as category I.
MAT- a 0.5 KVA 1 No 943
03844
MAT- b 1.0 KVA 1 No 1668
03845
MAT- c 3.0 KVA 1 No 2300
03846
MAT- d 4.0 KVA 1 No 3105
03847
MAT- e 5.0 KVA 1 No 3795
03848
285 ELEC-5.8.2 Supplly of ………... Stabilizer.
Makes : As per list of recommended brands as category II.

MAT- a 0.5 KVA 1 No 776


03849
MAT- b 1.0 KVA 1 No 1495
03850
MAT- c 3.0 KVA 1 No 1955
03851
MAT- d 4.0 KVA 1 No 2875
03852
MAT- e 5.0 KVA 1 No 3565
03853
5.9 REPAIRING OF FANS, COOLERS, PUMPS, MOTORS, FRIDGES AND
AIRCONDITIONERS
286 ELEC-5.9.1 Rewinding of ceiling fan motor (starting and running winding) including all
necessary material. The motor is to be wound taking no. of coils, turns
and pitch as it was originally wound with required size super enamelled
wire with 'E' class insulation material and making connections etc. as
required. (New model ceiling fan)
MAT- a 900/1200 mm sweep 1 No 406
03854
MAT- b 1400 mm sweep 1 No 488
03855
287 MAT- ELEC-5.9.2 Charges for oiling, greasing, 1 No 165
03856 overhauling of ceiling fan, table fan,
pedestal fan irrespect to the size of
fan including removing,refixing of fan
from site and testing etc. as required
288 MAT- ELEC-5.9.3 Providing and Replacement of ball 1 No 193
03857 bearing of ceiling/ exhaust fan as
required. (NBC/ SKF)

100
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
289 MAT- ELEC-5.9.4 Providing and Replacement of Gun 1 No 165
03858 metal bush of ceiling/ exhaust/cooler
fan/ as required
290 MAT- ELEC-5.9.5 Servicing and overhauling of 20" 1 No 275
03859 sweep desert cooler including oiling,
greasing, painting of tank from inside
with rubber paint after properly
desmantling each assembly and
refixing the same as required.
291 MAT- ELEC-5.9.6 Painting of desert cooler with two 1 No 495
03860 coats of rubber paint inside of water
tank and two coat of synthetic
enamelled paint on both side of cooler
body, fan body, grills etc.after
cleaning with sand paper, complete in
all respect as required
292 MAT- ELEC-5.9.7 Replacement of cooler pads (heavy) 1 No 165
03861 set of 3 no. of size 25" x 27"

293 MAT- ELEC-5.9.8 Supply and fixing of Brass float valve 1 No 220
03862 of weighing approx. 250 gm, 8" long
rod,PVC ball of 4" dia. For desert
coler as required.
294 MAT- ELEC-5.9.9 Supply and fixing of adjustable 1 No 396
03863 M.S.grill 20/22 gauge of size approx.
24" x 26" including painting etc. as
required
295 MAT- ELEC-5.9.10 Spray painting of ceiling fan of size 1 No 193
03864 900/1200/ 1400 mm with two coats of
white/ brown enamelled paint after
cleaning with sand paper. Filling etc.
as required.
296 ELEC-5.9.11 Rewinding of Heavy duty Exhaust fan motor including all necessary
material,The motor is to be wound taking no. of coils,turns and pitch as it
was originally wound with required size super enamelled wire with 'E'
class insulation material and making connections etc. as
required.

MAT- a 300/ 380 mm sweep 1 No 688


03865
MAT- b 450 mm sweep 1 No 813
03866
MAT- c 600 mm sweep 1 No 1375
03867
297 MAT- ELEC-5.9.12 Rewinding of 400 mm table 1 No 438
03868 fan/pedestal fan motor including all
necessary material,The motor is to be
wound taking no. of coils,turnsand
pitch as it was originally wound with
required size super enamelled wire
with 'E' class insulation material and
making connections etc. as required.

101
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
298 ELEC-5.9.13 Rewinding of single phase motor of 1 No
1400 RPM including all necessary
material and of the same
characteristics as original with
required size of super enamelled wire
'E' class insulation material and
testing etc. as required.
MAT- a 0.5 H.P. To 1.00 H.P. 1 No 840
03869
MAT- b 2.0 H.P 1 No 1380
03870
299 ELEC-5.9.14 Rewinding of three phase motor of 1400 to 2800 RPM including all
necessary material and of the same characteristics as original with
required size of super enamelled wire 'E' class insulation material and
testing etc. as required.
MAT- a 3.0 H.P. 1 No 2040
03871

MAT- b 5.0 H.P. 1 No 2880


03872
MAT- c 7.5 H.P 1 No 3120
03873
MAT- d 10.0 H.P 1 No 4200
03874
MAT- e 12.5 H.P 1 No 4440
03875
MAT- f 15.0 H.P 1 No 5400
03876
300 ELEC-5.9.15 Supply and charging of fresh refrigerant and testing of
performance of air conditioner/ fridge/ water cooler of following capacity
including capallary and strainer/ filter.

MAT- a 1.0 TR Window/ Split A.C 1 No 2090


03877
MAT- b 1.5 TR Window/ Split A.C 1 No 2310
03878
MAT- c 2.0 TR Window/ Split A.C 1 No 2750
03879
MAT- d 25/50 / 40/80 Ltr. Water cooler 1 No 2200
03880
MAT- e 60/120 Ltr. Water cooler 1 No 2530
03881
MAT- f 150/150 Ltr. Water cooler 1 No 3080
03882

102
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- g 165 Ltr Refrigerator 1 No 1375


03883
MAT- h 200/210 Ltr Refrigerator 1 No 1980
03884
MAT- i 286/310 Ltr Refrigerator 1 No 2310
03885
301 ELEC-5.9.16 Replacement of defective compressor by company repaired compressor
of fridge./water cooler including testing etc. as required.
Makes : As per list of recommended brands.
MAT- a 25/50 / 40/80 Ltr. Water cooler 1 No 6600
03886
MAT- b 60/120 Ltr. Water cooler 1 No 8360
03887
MAT- c 150/150 Ltr. Water cooler 1 No 9900
03888
MAT- d 165 Ltr Refrigerator) 1 No 3410
03889
MAT- e 200/210 Ltr Refrigerator 1 No 4180
03890
MAT- f 286/310 Ltr Refrigerator 1 No 4730
03891
302 ELEC-5.9.17 Supply of ……… brandnew Rotary type sealed compressor for Air
conditioner
Makes : As per list of recommended brands.
MAT- a 1.0/1.5 TR 1 No 10450
03892
MAT- b 2 TR 1 No 11495
03893
303 ELEC-5.9.18 Replacement of condensing/ cooling coil of copper fins for following
capacity A.C./ Water cooler/ Fridge as required

MAT- a 1.0 TR A.C. 1 No 3922


03894
MAT- b 1.5 TR A.C. 1 No 4428
03895
MAT- c 2.0 TR A.C. 1 No 4934
03896
MAT- d 25/50 / 40/80 Ltr. Water cooler 1 No 2640
03897
MAT- e 60/120 Ltr. Water cooler 1 No 3850
03898

103
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- f 150/150 Ltr. Water cooler 1 No 3850


03899
MAT- g 165 Ltr Refrigerator 1 No 1210
03900
MAT- h 200/210 Ltr Refrigerator 1 No 1320
03901
MAT- i 286/310 Ltr Refrigerator 1 No 1705
03902
304 MAT- ELEC-5.9.19 Replacement of overload protection of 1 No 550
03903 A.C./ Water cooler as required

305 MAT- ELEC-5.9.20 Replacement of thermostat of A.C./ 1 No 495


03904 Water cooler/fridge as required.

306 MAT- ELEC-5.9.21 Replacement of starting relay of 1 No 539


03905 A.C/water cooler/fridge compressor as
required
307 MAT- ELEC-5.9.22 Spray painting of complete fridge 1 No 1760
03906 (inside and outside ) of 165/
200/286/310 Ltr. Capacity
308 ELEC-5.9.23 Supply and fixing of 230V/ 275V,
50Hz rating ……….
Starting capacitor

MAT- a 20-60 micro farad 1 No 220


03907
MAT- b 80-150 micro farad 1 No 440
03908
Running capacitor 1 No

MAT- a 2.5/3.15/4.0/6.0 micro farad 1 No 83


03909
MAT- b 8.0 micro farad 1 No 121
03910
MAT- c 10.0 micro farad 1 No 165
03911
MAT- d 15.0 to 36.0 micro farad 1 No 385
03912
309 MAT- ELEC-5.9.24 Supply, Fabrication of 1set MS 1 Set 1320
03913 bracket suitable for fixing out door unit
of split AC unit.

310 ELEC-5.9.25 Providing 2 runs of Copper tubes for suction and liquid between indoor
and outdoor unit for split/Casseete Air- Conditioner including foaming
etc., complete.
Makes : As per list of recommended brands.

104
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- a 1/2" x 1/4" 1 Mtr 891


03914
MAT- b 5/8" x 1/4" 1 Mtr 979
03915
MAT- c 3/4" x 3/8" 1 Mtr 1073
03916
MAT- d 7/8" x 1/2" 1 Mtr 1210
03917
MAT- e 1 1/8" x 5/8" 1 Mtr 1485
03918
311 MAT- ELEC-5.9.26 Multi speed Fan Motor suitable for 1.0 1 No 1568
03919 / 1.5 / 2.0 Ton Window A.C.Unit
Makes : As per list of recommended
brands.
312 MAT- ELEC-5.9.27 Air filter suitable for 1.50 Ton Window 1 No 275
03920 A.C.Unit P.V.C. / NYLON.

313 MAT- ELEC-5.9.28 Air filter suitable for 1.50 Ton Split 1 No 473
03921 A.C.Unit P.V.C. / NYLON.

314 MAT- ELEC-5.9.29 Fan blade for 1.0 / 1.5 Ton 1 No 550
03922 A.C.Machine.

315 MAT- ELEC-5.9.30 Installation of Split Air Conditioners. 1 No 2000


03923
316 MAT- ELEC-5.9.31 Removing of existing Split Air 1 No 660
03924 Conditioners without damaging to
copper pipe.
317 MAT- ELEC-5.9.32 Installation of Cassette type Split Air 1 No 5000
03925 Conditioners.

318 MAT- ELEC-5.9.33 Installation of Tower type Split Air 1 No 3750


03926 Conditioners.

319 MAT- ELEC-5.9.34 Supply, Fabrication of 1set MS 1 Set 1870


03927 bracket suitable for fixing out door unit
of 3.5 /4.50 TR Casseete AC unit.
LAB- ELEC-5.9.35 Repairs and Installation of existing 1 No 650
01181 PCB in 1.0 / 1.5 / 2.0 Ton Split
A.C.Unit
LAB- ELEC-5.9.36 Overhauling and servicing the Split 1 Job 575
01182 type 1.5/2.0 Ton A.C. Machine by
Cleaning the condensor cooling Coil
etc., by blower and oiling the Fan
Motor and Cleaning all parts and
putting the machine in working
condition.
LAB- ELEC-5.9.37 Overhauling and servicing the 1 Job 780
01183 Cassette type 1.5/2.0/3.5/4.0 Ton A.C.
Machine by Cleaning the condensor

105
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

cooling Coil etc., by blower and oiling


the Fan Motor and Cleaning all parts
and putting the machine in working
condition.
SECTION 6

6.1 SWAGED / OCTAGONAL POLES AND GARDEN


POSTS
320 MAT- ELEC-6.1.1 Fabrication, supply and transportation 1 Kg 74
03928 of all sizes swaged poles up to site
confirming to IS 2713 / 1980
specifications. The pole should be
painted with primary coat of red oxide
and black bituminous paint up to
ground level with base plate, including
cost of all materials etc.,
complete.(Rate per K. G)
321 MAT- ELEC-6.1.2 Fabrication and Supply of M.S. Poles 1 Kg 67
03929 for garden posts with 'B' class
60.25mm outer dia with base plate
and suitable pole cap including cost
and conveyance of all material
including fixing of luminaire and labour
charges etc., complete. (Rate per K.
G)
322 MAT- ELEC-6.1.3 Supply of different sizes of M. S. Pipe 1 Kg 67
03930 brackets (Rate per K.G)

OCTOGONAL POLEs

323 MAT- ELEC-6.1.4 Fabrication, Transportation and 1 No 12936


03931 supply of hot-dip galvanized
Octogonal Pole with BSEN - 10025
grade S 355 JO steel plate for shaft,
IS 2062 for base plate with HInged
door opening arrangement, including
the supply of suitable boards with
bakelite sheet as per IS specification
suitable to withstand the wind speed
of 180 KMPH for 7.5 Mtrs height Pole
having dimensions Bottom 130 mm,.
Top 70mm with 3mm thick, base plate
220 x 220 x 12mm and 4 Nos of M20
x 700 long 'J' bolts along with
template.
Makes : As per list of recommended
brands.
324 MAT- ELEC-6.1.5 Fabrication, Transportation and 1 No 18700
03932 supply of hot-dip galvanized
Octogonal Pole with BSEN - 10025
grade S 355 JO steel plate for shaft,
IS 2062 for base plate with Hinged
door opening arrangement, including
the supply of suitable boards with
bakelite sheet as per IS specification

106
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

suitable to withstand the wind speed


of 180 KMPH for 9 Mtrs height Pole
having dimensions Bottom 155 mm,.
Top 70mm with 3mm thick, base plate
260 x 260 x 16mm and 4 Nos of M24
x 750 long 'J' bolts along with
template.
Makes : As per list of recommended
brands.

325 MAT- ELEC-6.1.6 Fabrication, Transportation and 1 No 20559


03933 supply of hot-dip galvanized
Octogonal Pole with BSEN - 10025
grade S 355 JO steel plate for shaft,
IS 2062 for base plate with HInged
door opening arrangement, including
the supply of suitable boards with
bakelite sheet as per IS specification
suitable to withstand the wind speed
of 180 KMPH for 10 Mtrs height Pole
having dimensions Bottom 175 mm,.
Top 70mm with 3mm thick, base plate
275 x 275 x16mm and 4 Nos of M24 x
750 long 'J' bolts along with template.
Makes : As per list of recommended
brands.

326 MAT- ELEC-6.1.7 Fabrication, Transportation and 1 No 29700


03934 supply of hot-dip galvanized
Octogonal Pole with BSEN - 10025
grade S 355 JO steel plate for shaft,
IS 2062 for base plate with door
opening arrangement, including the
supply of suitable boards with bakelite
sheet as per IS specification suitable
to withstand the wind speed of 180
KMPH for 12 mtrs height Pole having
dimensions Bottom 240mm, Top
100mm with 4mm thick, base plate
320 x320 x20mm and 4 Nos of M24 x
850 long 'J' bolts along with template.
Makes : As per list of recommended
brands.

DECORATIVE DRAGON TYPE BRACKET WITH


POLE
327 ELEC-6.1.8 Fabrication, Transportation and supply of hot-dip galvanized Octogonal
Pole with BSEN - 10025 grade S 355 JO steel plate for shaft, IS 2062 for
base plate with door opening arrangement, including the supply of
suitableboards with bakelite sheet and MCB's as per IS
specification suitable to withstand the wind speed of 180KMPH for 9 Mtrs
Mounting height Pole having dimensions Bttom 185 mm,. Top 70mm
with 3mm thick, base plate 275 x 275 x 20mm and 4 Nos of M24 x 1000
long 'J' bolts along with templates. Including Supply of1.5M Dragon
typedecorative ...................

107
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Makes : As per list of recommended brands.

MAT- a galvanised double arm with PU 1 No 29260


03935 Painted bracket.

MAT- b galvanised Single arm with PU 1 No 25080


03936 Painted bracket.

MAT- c Double arm GalvanizeFinished 1 No 24750


05544 bracket

MAT- d Single arm GalvanizeFinished bracket 1 No 22440


05545
328 ELEC-6.1.9 Fabrication, Transportation and 1 No DELETED
supply of hot-dip galvanized
Octogonal Pole with BSEN - 10025
grade S
355 JO steel plate for shaft, IS 2062
for base plate with
door opening arrangement, including
the supply of suitable boards with
bakelite sheet and MCB's as per IS
specification suitable to withstand the
wind speed of 180 KMPH for 9 Mtrs
Mounting height Pole having
dimensions Bottom 185 mm,. Top
70mm with 3mm thick, base plate 275
x 275 x 20mm and 4 Nos of M24 x
1000long 'J' bolts along with
templates. Including Supply of 1.5M
Dragon type decorative
329 ELEC-6.1.10 Fabrication, Transportation and supply of hot-dip ..................PU Paint
finish Curved Octogonal Pole with BSEN - 10025 grade S 355 JO steel
plate for shaft, IS 2062 for base plate with door opening arrangement,
including the supply of suitable boards with bakelite sheet and MCB's as
per IS specification suitable to withstand the wind speed of 180 KMPH for
9 Mtrs Mounting height Curved Pole having dimensions Bottom 180
mm,. Top 85mm with 3mm thick, base plate 400 x 400 x 20mm and 4
Nos of M24 x 750 long 'J' bolts along with templates. Including Supply of
0.2M long Single arm bracket.
Makes : As per list of recommended brands.
MAT- a Galvanized 1 No 24530
03937
MAT- b Galvanized PU paint finshed 1 No 33220
05546

108
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

POLE BRACKETS

330 MAT- ELEC-6.1.11 Fabrication, Transportation and 1 No 1430


03938 supply of 1.0 Mtr Length Single Arm
Bracket made with MS galvanized
40mm / 50mm dia Pipe.
Makes : As per list of recommended
brands.
331 MAT- ELEC-6.1.12 Fabrication, Transportation and 1 No 1892
03939 supply of 1.50 Mtr Length Single Arm
Bracket made with MS galvanized
40mm / 50mm dia Pipe.
Makes : As per list of recommended
brands.
332 MAT- ELEC-6.1.13 Fabrication, Transportation and 1 No 1771
03940 supply of 1 Mtr length Double Arm
Bracket made with MS galvanized
40mm / 50mm dia Pipe.
Makes : As per list of recommended
brands.
334 MAT- ELEC-6.1.15 Fabrication, Transportation and 1 No 5280
03942 supply of 1.5 Mtr Length Single Arm
suitable size decorative galvanized
Bracket with PU paint colour finish
etc complete.
Makes : As per list of recommended
brands.
335 MAT- ELEC-6.1.16 Fabrication, Transportation and 1 No 10010
03943 supply of 1.5 Mtr Length Double Arm
suitable size decorative galvanized
Bracket with PU paint colour finish
etc complete.
Makes : As per list of recommended
brands.
336 MAT- ELEC-6.1.17 Fabrication, Transportation and 1 No 5830
03944 supply of of 1.5mtrs sword type or
any decorative double arm bracket
with dooms either sides complete with
all accessories with MS galvanized
40mm / 50mm dia Pipe.
Makes : As per list of recommended
brands.
337 MAT- ELEC-6.1.18 Fabrication, Transportation and 1 No 4510
03945 supply of of 1.5mtrs sword type or
any decorative Single arm bracket
with dooms either sides complete with
all accessories with MS galvanized
40mm / 50mm dia Pipe.
Makes : As per list of recommended
brands.

109
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
338 MAT- ELEC-6.1.19 Fabrication, Transportation and 1 No 4730
03946 supply of of 1.0mtrs sword type or
any decorative double arm bracket
with dooms either sides complete with
all accessories with MS galvanized
40mm / 50mm dia Pipe.
Makes : As per list of recommended
brands.
339 MAT- ELEC-6.1.20 Fabrication, Transportation and 1 No 3960
03947 supply of of 1.0 mtrs sword type or
any decorative Single arm bracket
with dooms either sides complete with
all accessories with MS galvanized
40mm / 50mm dia Pipe.
Makes : As per list of recommended
brands.
HIGH MAST POLES

340 MAT- ELEC-6.1.21 Fabrication, transportation and supply 1 No 115500


03948 of 12 Mtrs Polygon High Mast with
single section of 3mm thick of Bottom
360mm and Top 150mm dia with
BSEN - 10025 grade S 355 JO steel
plate for shaft, IS 2062 for base plate,
having a base plate of size 520mm
dia 16mm thick with its accessories.
Mast shall be in single section for 12
Mtrs and 2 sections for 16 and 20
Mtrs. Mast shall be hot dip galvanized
and suiatble for wind velocity of 180
KMPH as per IS 875 part 3 including
head frame, 2 point suspension
system with steel rope 6mm dia (7/19)
construction double drum winch /
power tool operating speed of 900
RPM, and necessary cable trailer
connections and single speed motor
with M24 x 800 mm foundation bolts
of required quantity, suitable for 6
luminaires with GLS type aviation twin
lamp.
Makes : As per list of recommended
brands.
341 MAT- ELEC-6.1.22 Fabrication, transportation and supply 1 No 151800
03949 of 16 Mtrs Polygon High Mast with two
sections of Bottom 4mm thick and Top
section with 3mm thick with GLS type
aviation lamp of Bottom 360mm and
Top 150mm dia with BSEN - 10025
grade S 355 JO steel plate for shaft,
IS 2062 for base plate, having a base
plate of size 560mm dia 25mm thick
with its accessories. Mast shall be in
single section for 12 Mtrs and 2
sections for 16 and 20 Mtrs. Mast
shall be hot dip galvanized and

110
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

suiatble for wind velocity of 180


KMPH as per IS 875 part 3 including
head frame, 2 point suspension
system with steel rope 6mm dia (7/19)
construction double drum winch /
power tool operating speed of 900
RPM, and necessary cable trailer
connections and single speed motor
with M24 x 800 mm foundation bolts
of required quantity with GLS type
aviation twin lamp.
Makes : As per list of recommended
brands.
342 MAT- ELEC-6.1.23 Fabrication, transportation and supply 1 No 196350
03950 of 20 Mtrs Polygon High Mast with two
sections of Bottom 4mm thick and Top
section with 3mm thick of Bottom
460mm and Top 150mm dia with
BSEN - 10025 grade S 355 JO steel
plate for shaft, IS 2062 for base plate,
having a base plate of size 670mm
dia 25mm thick with its accessories.
Mast shall be in single section for 12
Mtrs and 2 sections for 16 and 20
Mtrs. Mast shall be hot dip galvanized
and suiatble for wind velocity of 180
KMPH as per IS 875 part 3 including
head frame, 2 point suspension
system with steel rope 6mm dia (7/19)
construction double drum winch /
power tool operating speed of 900
RPM, and necessary cable trailer
connections and single speed motor
with M30 x 750 mm foundation bolts
of required quantity with GLS type
aviation twin lamp.
Makes : As per list of recommended
brands.
FEEDER PILLAR BOXES

343 MAT- ELEC-6.1.24 Supply and fixing of suitable out door 1 No 20130
03951 type feeder piller box made with 14
SWG CRCA sheet after 7 tank
process including S & F 40-63A FP
MCB, 6 Nos SP MCB's, din chanel,
bus bars, 6 Sqmm 3 core copper
cable for internal wiring, contactor,
connectors and provision for energy
meter etc., complete for finished item
of work.
Makes : As per list of recommended
brands.

111
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
344 MAT- ELEC-6.1.25 Supply and fixing of suitable out door 1 No 20790
03952 type feeder piller box made with 14
SWG CRCA sheet after 7 tank
process including S & F 40-63A FP
MCB, 9 Nos SP MCB's,din chanel,
bus bars, 6 Sqmm 3 core copper
cable for internal wiring , contactor,
connectors and provision for energy
meter etc., complete for finished item
of work.
Makes : As per list of recommended
brands.
ERRECTION- HIGH MAST POLES

345 MAT- ELEC-6.1.26 Earth work exacavation with a 1 No 31240


03953 approximate quantity of 4.0 Cum for
errection of 12 Mtrs high mast and
refilling with a quantity of 0.53 Cum of
PCC 1:4:8, 1.50 Cum M 20 grade
concrete and (80 Kgs) reinforced steel
of 12mm / 10mm / 8mm, Soil bearing
capacity of 10 T/Sqm, Anchor plate
with cost and conveyance of all above
materials including labour charges for
errection of High Mast and Carraige
etc complete.
346 MAT- ELEC-6.1.27 Earth work exacavation with a 1 No 39050
03954 approximate quantity of 6.0 Cum for
errection of 16 Mtrs high mast and
refilling with a quantity of 0.65 Cum of
PCC 1:4:8, 2.60 Cum M 20 grade
concrete and (110 Kgs) reinforced
steel of 12mm / 10mm / 8mm, Soil
bearing capacity of 10 T/Sqm, Anchor
plate with cost and conveyance of all
above materials including labour
charges for errection of High Mast and
Carraige etc complete.
347 MAT- ELEC-6.1.28 Earth work exacavation with a 1 No 50160
03955 approximate quantity of 7.0 Cum for
errection of 20 Mtrs high mast and
refilling with a quantity of 0.75 Cum of
PCC 1:4:8, 3.60 Cum M20 grade
concrete and (140 Kgs) reinforced
steel of 12mm / 10mm / 8mm, Soil
bearing capacity of 10 T/Sqm, Anchor
plate with cost and conveyance of all
above materials including labour
charges for errection of High Mast and
Carraige etc complete.
348 ELEC-6.1.29 Supply of ……. Sizes thermo plastic cable junction boxes with IP66/67
weather proof, for outdoor installation with konckouts for cable entry
including terminals etc., complete (sizes in mm).
Makes : As per list of recommended brands.
MAT- a 155 X 210 X 92 1 No 1815

112
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

03956
MAT- b 205 X 255 X112 1 No 2640
03957
MAT- c 225 X 295 X 122 1 No 9295
03958
MAT- d 255 X 600 X 170 1 No 10230
03959
FOUNDATION AND ERRECTION
CHARGES OF POLES
349 MAT- ELEC-6.1.30 Erection charges for 7.50 Mts long 1 Job 4620
03960 Octagonal pole on bridge kerb portion
with 4 Nos, 8" Anchor bolts with
chemical treatment with suitable "J"
type bolts etc duly drilling holes to
RCC slab with V.C.C. M.15 concrete
for suitable base concreting with
necessary steel reinforcement work
and curing for 7 days etc. including
cost and conveyance of all material
and all labour charges etc.complete
as directed by the department officers.
350 MAT- ELEC-6.1.31 Foundation and erection charges with 1 Job 5390
03961 special T&P, for 7.50 Mtrs long
Octagonal /Conical pole duly erecting
on base plate duly providing 4 Nos
foundation bolts with nuts with
providing of 0.45Mtr x 0.45Mtrs x1.20
Mtr size M20 cc work vibrated
concreting mixing with necessary
steel (10kgs) reinforcement and
curing for 7 days as directed by the
field engineers during execution
including excavation of Earth/BT all
labour charges and cost and
conveyance of materials etc.complete.
351 MAT- ELEC-6.1.32 Foundation and erection charges with 1 Job 7260
03962 special T&P, for 9.00Mtrs / 10Mtrs
long Octagonal / Conical pole duly
erecting on base plate duly providing
4 Nos foundation bolts with nuts with
providing of 0.60Mtr x 0.60Mtrs x 1.40
Mtr size M20 cc work vibrated
concreting mixing with necessary
steel (15kgs) reinforcement and
curing for 7 days as directed by the
field engineers during execution
including excavation of Earth/BT all
labour charges and
cost and conveyance of materials
etc.complete.

113
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
352 MAT- ELEC-6.1.33 Foundation and erection charges with 1 Job 8910
03963 special T&P, for 12Mtrs long
Octagonal /Conical pole duly erecting
on base plate duly providing 4 Nos
foundation bolts with nuts with
providing of 0.67Mtr x 0.67Mtrs x 1.50
Mtr size M20 cc work vibrated
concreting mixing withnecessary steel
(20kgs) reinforcement and curing for 7
days as directed by the field
engineers during execution including
excavation of Earth/BT all labour
charges and cost and conveyance of
materials etc.complete.
GRP POLES

353 ELEC-6.1.34 Supply and transportation of following glass reinforced polymer (GRP)
composite type Conical pole with single arm bracket of length 1Mtr and
internal junction box including labour charges etc., complete.
Makes : As per list of recommended brands.

MAT- a …do…. 3.00 Mtrs height, Bottom dia 1 No 9350


03964 143mm, Top 76mm, AV thickness
6mm and to withstand maximum wind
velocity 180Km/Hr
MAT- b …do…. 4.00 Mtrs height, Bottom dia 1 No 11880
03965 143mm, Top 76mm, AV thickness
6mm and to withstand maximum wind
velocity 180Km/Hr
MAT- c …do…. 6.00 Mtrs height, Bottom dia 1 No 14850
03966 143mm, Top 76mm, AV thickness
6mm and to withstand maximum wind
velocity 180Km/Hr
MAT- d …do…. 8.00 Mtrs height, Bottom dia 1 No 19140
03967 193mm, Top 76mm, AV thickness
6mm and to withstand maximum wind
velocity 180Km/Hr
MAT- e …do…. 9.00 Mtrs height, Bottom dia 1 No 20900
03968 210mm, Top 76mm, AV thickness
6mm and to withstand maximum wind
velocity 180Km/Hr
MAT- f …do…. 10.00 Mtrs height, Bottom dia 1 No 30250
03969 227mm, Top 76mm, AV thickness
6mm and to withstand maximum wind
velocity 180Km/Hr
354 ELEC-6.1.35 Supply and transportation of base bracket suitable for glass reinforced
polymer (GRP) composite type pole including labour charges etc.,
complete.
Makes : As per list of recommended brands.
MAT- a …do…. For 3.00 Mtrs Pole 1 No 1705
03970

114
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b …do…. For 4.00 Mtrs Pole 1 No 1705


03971
MAT- c …do…. For 6.00 Mtrs Pole 1 No 2035
03972
MAT- d …do…. For 8.00 Mtrs Pole 1 No 2365
03973

MAT- e …do…. For 9.00 Mtrs Pole 1 No 4510


03974
MAT- f …do…. For 10.00 Mtrs Pole 1 No 5610
03975
6.2 LT PANEL AND ACCESSORIES

355 MAT- ELEC-6.2.1 Supply Installation Testing and 1 sqm 4675


03976 commissioning of free standing floor
mounted dust and vermin proof
compartmentalised cubical panel
made out of CRCA sheet, required
hardware, duly painted by two coats
of zinc/red oxide primer followed by
Powder coated / epoxy / PU painted
with phosphatisation in grey or
required shade after rinsing. The
panel having PU/Neoprene rubber
gasket of not less than 3mm
thickness,separate detachable, gland
plate M.S. base channel, hinged door
with locking arrangement for
equipment/switchgear. Thickness of
sheet shall not be less than 1.6mm up
to 600mm length/width of any
compartment and be of 2.0mm above
600mm. Load bearing structure shall
be of 2.0mm thick sheet supported by
base M.S. channel if required. Side
walls and cable alley compartments
having bolted type doors with
detachable extension type structure
(only outer area on all sides shall be
measured and panel to be abricated
from CPRI approved fabricator).
356 ELEC-6.2.2 Supply and fixing of…………….. bus bar by means of SMC / DMC type
insulator, high tensile nuts and bolts spring washers in existing panel
including bending , cutting in required shape and size and colour coding
with heat shrinkable PVC sleeves

MAT- a Electrolytic grade aluminium bus bar kg 413


03977
MAT- b Electrolytic grade copper bus bar kg 825
03978

115
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
357 ELEC-6.2.3 Supply and Fixing of (0-500) V range Volt meter on existing panel ,
making connection by PVC insulated copper conductor with PVC sleeves
/ channel etc. as required.
Makes : As per list of recommended brands.
MAT- a Analog type ( 96 mm x 96 mm ) 1 No 935
03979
MAT- b Digital type 1 No 2090
03980
358 ELEC-6.2.4 Supply and Fixing of CT operated direct reading type Ammeter on
existing panel , making connection by PVC insulated copper conductor
with PVC sleeves / channel etc. as required.
Makes : As per list of recommended brands.
Analog type ( 96 mm x 96 mm )

MAT- a Below 500 A 1 No 935


03981
MAT- b Above 500A 1 No 935
03982
Digital type

MAT- c Below 500 A 1 No 2090


03983
MAT- d Above 500 A 1 No 2090
03984
359 ELEC-6.2.5 Supply and Fixing of Current Transformer , with all necessary support in
existing panel including connection etc. as required:
Makes : As per list of recommended brands.
MAT- a up to 150 / 5 Ratio , 5 VA , class 1 1 No 523
03985 accuracy

MAT- b from 200 / 5 to 400/5 Ratio , 10 VA , 1 No 770


03986 class 1 accuracy

MAT- c from 500 / 5 to 1600/5 Ratio , 15 VA , 1 No 1045


03987 class 1 accuracy

MAT- d from 2000 / 5 to 3200 /5 Ratio , 15 1 No 1650


03988 VA, class 1 accuracy

360 MAT- ELEC-6.2.6 Supply and Fixing of selector switch 1 No 374


03989 for voltmeter (4 position ) including
making connection etc. as required
Makes : As per list of recommended
brands.

361 MAT- ELEC-6.2.7 Supply and Fixing of CT linked 1 No 413


03990 selector switch of 10 A for Ampere
meter (4position ) including making
connection etc. as required.
Makes : As per list of recommended
brands.

116
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
362 ELEC-6.2.8 Supply and fixing of single phase Electronic energy Meter,……...AC,50
HZ as per IS13010 up to 40A range with 200% over load capacity
complete with connections etc., complete on the existing board.
Makes : As per list of recommended brands.

MAT- a Single Phase 1 No 1100


03991
MAT- b Three Phase 1 No 3080
03992
363 ELEC-6.2.9 Supply and Fixing of 240/220 V, LED (22.5 mm dia ) Pilot lamp with
integral circuit, terminal block, including connection etc. as required

MAT- a Red/yellow/Green colour 1 No 132


03993
MAT- b Blue colour 1 No 220
03994
364 ELEC-6.2.10 Supply and Fixing of Tap-off boxes suitable for following size of approved
design

MAT- a up to 95 sq. mm.( 3.5/4 core ) 1 No 440


03995
MAT- b from 120 sq. mm. to 185 sq. mm.( 1 No 770
03996 3.5/4 core )

365 MAT- ELEC-6.2.11 Supply and Fixing of energy analyser 1 No 11550


03997 (multy function energy meter) with
LCD/LED display capable of minimum
20 numbers electrical parameters
display with 1A/5A CT input for LV/
HV network, RS 485
communication port etc. complete in
all respect.
366 ELEC-6.2.12 Supply Installation Testing and commissioning of self healing MPP/MP
type shunt capacitor (banks) conforming to IS:13340-41 / IEC :831-1&2 in
existing panel or parallel with load terminals , the capacitor shall be fitted
with discharge resistors, pressure sensitive disconnector ( PSD ) and
shall have dissipation factor less than 0.0025 at 50 Hz and total wattage
loss less than 0.5 Watt per KVAR. including making connections with
suitable capacity conductors/cables testing as
required.
Makes : As per list of recommended brands.
MAT- a Standard duty Single phase 250 V / 1 KVAR 220
03998 Three phase 440 V, 50 Hz capacitor
(Bank)
MAT- b Heavy duty Three phase 440 V , 50 1 KVAR 330
03999 Hz capacitor (Bank)

117
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
367 MAT- ELEC-6.2.13 Supply Installation Testing and commissioning of microprocessor based
04000 intelligent power factor correction relay having sensitivity up to 50 milli
Amp secondary current and following way, self analysing auto c/k setting
according to targeted power factor setting, the relay shall have minimum
three digit display unit for display of real power factor, targeted power
factor, lag/lead capacitor switching status, alarm output for under current,
over current, insufficient compensation, indication of switching on units,
auto/manual status, and shall have over load protection, no volt release
etc. as required.
Makes : As per list of recommended brands.
6 to 14 stage - sensitivity upto 50 milli 1 No 20350
Amp
368 ELEC-6.2.14 Supply and Fixing of Cam operated rotary switches on existing panel with
2 way and off position.
Makes : As per list of recommended brands.
one pole

MAT- a 16 A 1 No 385
04001
MAT- b 32 A 1 No 495
04002
MAT- c 63 A 1 No 715
04003
Two pole

MAT- d 16 A 1 No 440
04004
MAT- e 32 A 1 No 583
04005
MAT- f 63 A 1 No 963
04006
Three pole

MAT- g 16 A 1 No 550
04007
MAT- h 32 A 1 No 770
04008
MAT- i 63 A 1 No 1375
04009
Four pole

MAT- j 16 A 1 No 550
04010
MAT- k 32 A 1 No 825
04011
MAT- l 63 A 1 No 1540

118
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

04012
369 ELEC-6.2.15 Supply and Fixing of ac operated heavy duty 230 /440 Volt power
contactor conforming to IS:13947-4-1/IEC:947-4-1 having provision of
mechanical interlocking, Din rail mounting type including making
connections, testing etc. as required.
Makes : As per list of recommended brands.
3 pole AC3 Rating contactors

MAT- a Up to 12 Amp 1 No 880


04013
MAT- b 13 to 32 Amp 1 No 1458
04014
MAT- c 35 to 40 Amp 1 No 1760
04015
MAT- d 41 to 50 Amp 1 No 3850
04016
4 pole AC 1 Rating contactors

MAT- e Up to 25 Amp 1 No 1100


04017
MAT- f 26 to 32 Amp 1 No 1320
04018
MAT- g 33 to 45 Amp 1 No 2200
04019
MAT- h 46 to 60 Amp 1 No 4620
04020
370 ELEC-6.2.16 Supply and Fixing of 440 Volt 3 pole capacitor (AC 6 B ) duty contactor
with 3 no. early make and post break auxiliary contacts in series with
quick dischargedamping resistors/ reactors to limit the inrush current
,conforming to IS:13947-4-1/IEC:947-4-1, Din rail mounting type ncluding
making onnections, testing etc. as required. suitable for following
capacity capacitor bank .
Makes : As per list of recommended brands.
MAT- a Up to 6 KVAR 1 No 1760
04021
MAT- b 7 to 10 KVAR 1 No 1980
04022
MAT- c 11 to 20 KVAR 1 No 2970
04023
MAT- d 21 to 25 KVAR 1 No 3960
04024

MAT- e 30 KVAR 1 No 5720


04025
MAT- f 40 KVAR 1 No 9130

119
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

04026
MAT- g 50 KVAR 1 No 10560
04027
371 ELEC-6.2.17 Supply and Fixing of thermal over load relay with built in single phase
protection and having at least 1NO & 1NC contacts, manual /auto reset
facility including making connection testing etc. as required.
Makes : As per list of recommended brands.
MAT- a Up to 14 A 1 No 1320
04028
MAT- b 15 to 20 A 1 No 1760
04029
MAT- c 21 to 30 A 1 No 2530
04030
MAT- d 31 to 40 A 1 No 2860
04031
372 ELEC-6.2.18 Supply and Fixing of push button actuators and integral contact block of
dia. 22.5 mm including making connection etc. as required.
Makes : As per list of recommended brands.
MAT- a Non luminous type 1 No 105
04032
MAT- b Luminous type 1 No 143
04033
6.3 SUB STATION EQUIPMENT AND
TRANSFORMERS
373 MAT- ELEC-6.3.1 Supply, Installation, Testing & 1 No 26400
04034 Commissioning of HT metering
cubical panel as approved By
DISCOMs fabricated out of 14 SWG
CRCA sheet steel in two compartment
& MS angle of size 60mmX6mm
having provision for Following:
Makes : As per list of recommended
brands.
(i) Provision for fixing Trivector Meter (To be supplied by DISCOMs)

(ii) Provision for fixing of combined CT PT Set (To be supplied by


DISCOMs)
(iii)TT Block

(iv) 6mm Bakelite sheet on all sides.

120
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-6.3.1a Supply, Transportation, Installation and 132000


05547 Commissioning of 11 KV, 630A, 25 KA Outdoor type
Load Break Switch as detailed below with suitable CC
foundation and 2 Nos GI pipe earthing with brick
massonry chambers etc complete for finished item of
work.
Makes : As per list of recommended brands.
a) Load break switch: 11KV,630A, 25 KA with fuse
trip, earth switch, manually operated spring chargesd
mechanis with 2 no + 2 NC.
b) HT HRC fuse upto 63A - 3 nos.
c) Bus bar connection.
d) Indication lamps.
e) Manual trip Push buttion.
33 KV HT Panel (drawout type)

374 MAT- ELEC-6.3.2 Supply, Installation, Testing and 1No 2920500


04035 Commissioning of indoor type floor
mounted metal clad, 33 KV 800A
VCB Panel with 3 Nos. VCBs suitable
for 50Hz 3-phase system, suitable for
31.5kA/3sec short circuit withstand
capacity & 31.5kA/1sec Internal Arc
capacity. Switchgear Panel enclosure
of sheet steel preferably Aluzinc, dust
tight, vermin proof, totally enclosed
cubicle floor mounting, free standing
type with single break, horizontally
drawout type breaker with trip free
mechanism as per latest standard i.e.
IS/IEC 62271-200 as amended up to
date and as per Technical
specifications, IP4X for VCB Panel
enclosure. Switchgear Panel shall be
electrically & mechanically interlocked
as per IEC 62271-1, full voltage
insulated copper Busbar with heat
shrinkable sleeving, complete with
suitable metering & protection
devices, breaker featured with
mechanical ON-OFF indicator with
hand trip device and all accessories
such as shunt trip coil, motorized &
manually operated spring charging
mechanism, emergency trip push
buttons, auxiliary switch of 2NO +
2NC, interconnections, space heaters,
panel earthing etc. and equipped with
following switchgear and accessories
including connection suitable for
3x185 to 3x 400 sqmm XLPE 33 kV
cable (cable entry from bottom) to be
connected through heat shrinkable
jointing material etc as required.
(Note - Cost of end termination not
included in this item.)
Makes : As per list of recommended

121
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

brands.

INCOMER 1 No. each comprising


the following
1 No. 800 Amp. VCB. 31.5KA

1 No. Integral Earth switch for line


side earthing
3 No. dual core CTs 600A/1/1A of 7.5VA burden max and accuracy Class
0.5 for metering and class 5P10 for protection

3 No. Cast Resin 33000V/v3/110V/v3/110V/v3 PT Class 0.5/3P accuracy


and 30VA burden max with and protection fuses / MCB.

1 No. Digital voltmeter with selector


switch.
1 No. Digital Ammeter with selector
switch.
1 No. Microprocessor based numerical relays with O/L, E/F and S/C
protection with Integrated Arc sensing feature alongwith trip/lockout /
antipumping / aux. relays.
1 No. Multi-function meter.

Set of MCBs for Panel AC/DC

Set of MCBs for Main AC/DC

Set of Indication lamps LED types

TNC Switch, L-R Switch, Pushbuttons


for ON-OFF
OUTGOING 2 Nos. each comprising
the following
1 No. 800 Amp. VCB.31.5KA

1 No. Integral Earth switch for line


side earthing
3 No. dual core CTs 300A/1/1A of 7.5VA burden max and accuracy Class
0.5 for metering and class 5P10 for protection

1 No. Digital Ammeter with selector


switch.
1 No. Microprocessor based numerical relays with O/L, E/F and S/C
protection with Integrated Arc sensing feature alongwith trip/lockout /
antipumping / aux. relays.
Set of MCBs for Panel AC/DC

Set of Indication lamps LED types

TNC Switch, L-R Switch, Pushbuttons

122
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

for ON-OFF

11KV HT Panel (drawout type)

375 MAT- ELEC-6.3.3 Supply, Installation, Testing and 1No 1479500


04036 Commissioning of indoor type floor
mounted metal clad, 11 KV 800A
VCB Panel with 3 Nos. VCBs suitable
for 50Hz 3-phase system, suitable for
26.3kA/3sec short circuit withstand
capacity & 26.3kA/1sec Internal Arc
capacity. Switchgear Panel enclosure
of sheet steel preferably Aluzinc, dust
tight, vermin proof, totally enclosed
cubicle floor mounting, free standing
type with single break, horizontally
drawout type breaker with trip free
mechanism as per latest standard i.e.
IS/IEC 62271-200 as amended up to
date and as per Technical
specifications, IP4X for VCB Panel
enclosure. Switchgear Panel shall be
electrically & mechanically interlocked
as per IEC 62271-1, full voltage
insulated copper Busbar with heat
shrinkable sleeving, complete with
suitable metering & protection
devices, breaker featured with
mechanical ON-OFF indicator with
hand trip device and all accessories
such as shunt trip coil, motorized &
manually operated spring charging
mechanism, emergency trip push
buttons, auxiliary switch of 2NO +
2NC, interconnections, space heaters,
panel earthing etc. and equipped with
following switchgear and accessories
including connection suitable for
3x185 to 3x 400 sqmm XLPE 11kV
cable (cable entry from bottom) to be
connected through heat shrinkable
jointing material etc as required.
(Note - Cost of end termination not
included in this item.)
Makes : As per list of recommended
brands.
INCOMER 1 No. each comprising
the following
1 No. 800 Amp. VCB. 26.3KA

1 No. Integral Earth switch for line


side earthing
3 No. dual core CTs 600A/1/1A of 7.5VA burden max and accuracy Class
0.5 for metering and class 5P10 for protection

123
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

3 No. Cast Resin 11000V/v3/110V/v3/110V/v3 PT Class 0.5/3P accuracy


and 30VA burden max with and protection fuses / MCB.

1 No. Digital voltmeter with selector


switch.
1 No. Digital Ammeter with selector
switch.
1 No. Microprocessor based numerical relays with O/L, E/F and S/C
protection with Integrated Arc sensing feature alongwith trip/lockout /
antipumping / aux. relays.
1 No. Multi-function meter.

Set of MCBs for Panel AC/DC

Set of MCBs for Main AC/DC

Set of Indication lamps LED types

TNC Switch, L-R Switch, Pushbuttons


for ON-OFF
OUTGOING 2 Nos. comprising the
following
1 No. 800 Amp. VCB. 26.3KA

1 No. Integral Earth switch for line


side earthing
3 No. dual core CTs 300A/1/1A of 7.5VA burden max and accuracy Class
0.5 for metering and class 5P10 for protection

1 No. Digital Ammeter with selector


switch.
1 No. Microprocessor based numerical relays with O/L, E/F and S/C
protection with Integrated Arc sensing feature alongwith trip/lockout /
antipumping / aux. relays.

Set of MCBs for Panel AC/DC

Set of Indication lamps LED types

TNC Switch, L-R Switch, Pushbuttons


for ON-OFF
Oil Immersed TRANSFORMERS

376 ELEC-6.3.4 Supply and Transportation of copper wound Transformers 33/0.433 KV,
Three Phase, 50 Hz, DYN 11, ONAN type , Standard accessories,
winding temperature rise of 45°C/40°C first fill oil, having permissible total
loss values not exceeding 7.5%of the maximum total loss values for 33
KV as per energy efficiency level - 2 at basic Insulation level conforming
to ISS 2026 (Part- I to Part - II), latest ammended and IS 1180 Part-I :
2014 described as above with Cable box on HV side and Bus duct on LV
Side , ON load Tap changer(OLTC) with RTCC etc., with initial filling of
oil as per IS 335-1993 complete and as per the following continuous
rating.

124
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Makes : As per list of recommended brands as category I.

MAT- a 630 KVA 1 No 1127000


04037
MAT- b 1000 KVA 1 No 1437500
04038
MAT- c 1250 KVA 1 No 1725000
04039
MAT- d 1600 KVA 1 No 2139000
04040
MAT- e 2000 KVA 1 No 2645000
04041
ELEC-6.3.4 A Supply and Transportation of copper wound Transformers 33/0.433 KV, Three
Phase, 50 Hz, DYN 11, ONAN type , Standard accessories, winding temperature
rise of 45°C/40°C first fill oil, having permissible total loss values not exceeding
7.5%of the maximum total loss values for 33 KV as per energy efficiency level - 2
at basic Insulation level conforming to ISS 2026 (Part- I to Part - II), latest
ammended and IS 1180 Part-I : 2014 described as above with Cable box on HV
side and Bus duct on LV Side , ON load Tap changer(OLTC) with RTCC etc.,
with initial filling of oil as per IS 335-1993 complete and as per the following
continuous rating
Makes : As per list of recommended brands as category II.
MAT- a 630 KVA 980000
08768
MAT- b 1000 KVA 1250000
08769
MAT- c 1250 KVA 1500000
08770
MAT- d 1600 KVA 1860000
08771
MAT- e 2000 KVA 2300000
08772
ELEC-6.3.5 Supply, Transportation, Installation, Testing and Commissioning of ------ KVA
TRANSFORMER with all test reports. The Transformer shall be
designed and manufactured as per Energy Efficiency Level - 2 at basic Insulation
level conforming to ISS 2026 (Part- I to Part - II) with latest ammended,and as per
IS 1180 Part-I : 2014 latest ammended, OCTC with initial filling of oil as per
IS 335-1993. The basic details of the Transformer are as under.
Makes : As per list of recommended brands as category I.
1. Quantity : 1
2. Rated KVA : ........KVA
3. Service & Location: Continuous
Outdoor

125
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Distribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40⁰C in oil, 45⁰C by
resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current :
_
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ
+/- 3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for
primary voltage variation : +5% to -
10% in steps of 2.5% of 7 position (6
Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the
sitecondition.
b. LV: Cable box suitable to receive ---
-------
--Sq.mm XLPE cable
22. LV:One separate terminal for
earthing.
23. Total Losses at 50% Loading
[Watts] [Max] --- as per IS
24. Total Losses at 100% Loading
[Watts] [Max]--- as per IS
25.Percentage Impedance at 75 deg.
C at -----as per IS
26. No Load current: Less than 2% of
full load current.
27. Standard Fittings & Accessories.
a. Rating and terminal marking plate:
One
b. Lifting Lugs: Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable):Adequate
f. Explosion vent with Diaphragm
:One
g. Conservator with Drain plug: one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silica gel Breather :
One
k. Terminal Arrangement: HV With
TerminalBox
l. Terminal Arrangement : LV Cable

126
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Box
m. Separate Neutral Bushing : One
n. Drain cum filter valve with blanking
plate: One
o. Air release device : One
p. Thermometer Pocket : One
q. Four :Unidirectional flat rollers
r. One :10Cm dial thermometer (Rigid
stemtype)
MAT-04042 a 100 KVA Copper Wound Transformer 1 No 360000

MAT-04043 b 160 KVA Copper Wound Transformer 1 No 594000

MAT-04044 c 250 KVA Copper Wound Transformer 1 No 713000

MAT-04045 d 315 KVA Copper Wound Transformer 1 No 950000

MAT-04046 e 500 KVA Copper Wound Transformer 1 No 1247000

MAT-04047 f 630 KVA Copper Wound Transformer 1 No 1343000

MAT-04048 g 1000 KVA Copper Wound Transformer 1 No 1758000

ELEC-6.3.5 A Supply, Transportation, Installation, Testing and Commissioning of --


---- KVA TRANSFORMER with all test reports. The Transformer
shall be designed and manufactured as per Energy Efficiency Level - 2
at basic Insulation level conforming to ISS 2026 (Part- I to Part - II) with
latest ammended,and as per IS 1180 Part-I : 2014 latest ammended,
OCTC with initial filling of oil as per IS 335-1993. The basic details
of the Transformer are as under.
Makes : As per list of recommended brands as category II.
1. Quantity : 1
2. Rated KVA : ........KVA
3. Service & Location: Continuous
OutdoorDistribution Transformer
4. Mounting : Plinth.
5. Wound : Copper Double wound
6. Type : Core type oil immersed
7. Cooling : ONAN
8. Temp Rise : 40⁰C in oil, 45⁰C by
resistance
9. Vector Group: Dyn 11
10. Primary Connection : Delta
11. Nominal Voltage / Current : _
12. Highest system Voltage: 12000V
13. Primary Frequency :50 HZ +/-
3%
14. Number of Phases : 3
15. Primary wires: 3
16. Secondary connection : Star
17. Secondary Volts / Current : 433V
18. Secondary phases : 3
19. Secondary wires: 4
20. Taps on primary winding for primary
voltage variation : +5% to - 10% in steps
of 2.5% of 7 position (6 Steps)
21. Terminal arrangement.
a.HV: HT terminal box as per the
sitecondition.

127
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

b. LV: Cable box suitable to receive -----


-----
--Sq.mm XLPE cable
22. LV:One separate terminal for
earthing.
23. Total Losses at 50% Loading
[Watts] [Max] --- as per IS
24. Total Losses at 100% Loading
[Watts] [Max]--- as per IS
25.Percentage Impedance at 75 deg. C
at -----as per IS
26. No Load current: Less than 2% of
full load current.
27. Standard Fittings & Accessories.
a. Rating and terminal marking plate:
One
b. Lifting Lugs: Two
c. Off-circuit tap switch :One
d. Earthing Terminals :Two
e. Radiators ( Attachable):Adequate
f. Explosion vent with Diaphragm
:One
g. Conservator with Drain plug: one
h. Oil filling hole with cap :One
i. Oil level indicator : One
j. Dehydrating Silica gel Breather : One
k. Terminal Arrangement: HV With
TerminalBox
l. Terminal Arrangement : LV Cable Box
m. Separate Neutral Bushing : One
n. Drain cum filter valve with blanking
plate: One
o. Air release device : One
p. Thermometer Pocket : One
q. Four :Unidirectional flat rollers
r. One :10Cm dial thermometer (Rigid
stemtype)

MAT- a 100 KVA Copper Wound Transformer 1 No 325500


08773
MAT- b 160 KVA Copper Wound Transformer 1 No 550000
08774
MAT- c 250 KVA Copper Wound Transformer 1 No 650000
08775
MAT- d 315 KVA Copper Wound Transformer 1 No 800000
08776
MAT- e 500 KVA Copper Wound Transformer 1 No 1050000
08777
MAT- f 630 KVA Copper Wound Transformer 1 No 1130000
08778
MAT- g 1000 KVA Copper Wound Transformer 1 No 1480000
08779
ELEC-6.3.5 B Supply and Transportation of ISI marked copper wound Transformers

128
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONANtype , Standard


accessories, winding temperature rise of 45°C/40°C first fill oil, having
permissible total loss values not exceeding 7.5%of the maximum total
loss values for 11 KV as per Energy Efficiency Level - 2 at basic
Insulation level conforming to ISS 2026 (Part- I to Part - II), latest
ammended and IS 1180 Part-I : 2014 described as above with Cable box
on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10%
to -10%, with RTCC etc., with initial filling of oil as per IS 335-1993
complete and as per the following continuous rating.
Makes : As per list of recommended brands as category I.
MAT- a 630 KVA 1 No 1593000
08780
MAT- b 1000 KVA 1 No 2008000
08781
ELEC-6.3.5 C Supply and Transportation of ISI marked copper wound Transformers
11/0.433 KV, Three Phase, 50 Hz, DYN 11, ONANtype , Standard
accessories, winding temperature rise of 45°C/40°C first fill oil, having
permissible total loss values not exceeding 7.5%of the maximum total
loss values for 11 KV as per Energy Efficiency Level - 2 at basic
Insulation level conforming to ISS 2026 (Part- I to Part - II), latest
ammended and IS 1180 Part-I : 2014 described as above with Cable box
on HV side and Bus duct on LV Side , ON load Tap changer(OLTC)+10%
to -10%,with RTCC etc., with initial filling of oil as per IS 335-1993
complete and as per the following continuous rating.
Makes : As per list of recommended brands as category II.
MAT- a 630 KVA 1 No 1355000
08782
MAT- b 1000 KVA 1 No 1705000
08783
Dry Type transformers

378 ELEC-6.3.6 Supply ,Transportation of cast Resin (Dry Type) indoor type copper
double wound 33KV/0.433 KV, Three Phase 50 HzTransformers
desingned and manufactured as per IS 11171/IEC 60726 , ANSI and
NEMA Standards with all standard fittings,connected Delta on Primary
side and Star on Secondary side with additional neutral brought out on
load side 33000/433V with HV off load tap changing +5% to -15%
temperature rise by the resistance 90 degrees with terminal arrangement
Cable box on HV side and Bus duct on LV Side with off circuit Tap links
etc.,, completeMakes : As per list of recommended brands.

MAT- a 1000 KVA 1 No 3047500


04049
MAT- b 1250 KVA 1 No 3795000
04050
MAT- c 1600 KVA 1 No 4588500
04051
MAT- d 2000 KVA 1 No 5520000
04052
MAT- e 2500 KVA 1 No 6210000
04053

129
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
379 ELEC-6.3.7 Supply, Transportation, Installation, Testing and Commissioning of 3
Phase, 50 Hz, Dry type, Indoor type copper wound Transformer
designed and manufactured as per IS 2026-1977 and IS 11171-
1985, connected delta on primary side and Star on secondary side with
additional neutral brought out on load side, 11000V / (433V /415V)
with HV off load tap changing + 5% to -5% in steps of 2.5%,
temperature rise by the resistance 90⁰C complete with test
reports with the following standard mountings.
Makes : As per list of recommended brands.
1. Rated KVA : ........KVA (Cast Resin)

2. Service: Indoor

3. Mounting : Floor.

4. Copper wound : Double.

5. Type of cooling : ANAN.

6. Insulation Class : Class F

7. Temperature rise by resistance : 90⁰C

8. Vector Group: Dyn 11

9. Primary Connection : Delta

10. Primary Volts : 11000

11. Primary Frequency : 50

12.Primary Phases : 3

13. Primary wires: 3

14. Secondary connection : Star

15. Secondary Volts : 433V / 415V

16. Secondary phases : 3

17. Secondary wires: 4

18. Taps on primary winding for primary


voltage variation : +5.0% to - 10.0% in
steps of 2.5% through links.
19. Terminal arrangement.

a. HV: Cable end box b. LV : Cable end


box
20. No load losses (Watts): ........... As per
IS
specifications
21. Load losses (Watts): ..............As per
IS
specifications
22. Impedance(Z%) : ............As per IS
specifications

130
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
23. Fittings & Accessories.

a. Rating and terminal marking plate b.


Earthing terminals
c. Lifting Lugs

d. Winding temperature Indicator

e. Separate neutral bushing

f. Uni directional flat rollers.

MAT- a 250 KVA Copper Wound Cast Resin 796000


Transformer
04054
MAT- b 315 KVA Copper Wound Cast Resin 915000
Transformer
04055
MAT- c 500 KVA Copper Wound Cast Resin 1247000
Transformer
04056
MAT- d 630 KVA Copper Wound Cast Resin 1366000
Transformer
04057
MAT- e 750 KVA Copper Wound Cast Resin 1604000
Transformer
04058
MAT- f 1000 KVA Copper Wound Cast Resin 2020000
Transformer
04059
6.4 MAINTENANCE AND REPAIRS OF
TRANSFORMERS
380 MAT- ELEC-6.4.1 Carryout routine maintenance, 1 No 5500
04060 servicing and testing of 630A to
1000A L.T.ACB by cleaning fixed
contacts, moving contacts and
arcchutes including servicing and
putting the ACB in perfect working
condition after detting all relay and
ON, OFF mechanism etc done with
only manufacturing companies
381 MAT- ELEC-6.4.2 Carryout routine maintenance and 1 No 3300
04061 servicing of LT.Cubical pannel board
having approximately 15 to 22 Nos of
switches cleaning with power blower
and servicing the contacts, tightning
the connection of incoming and
outgoing cables, and checking the
operating machanism for smooth
functioning of switches and putting
them in smooth working condition.
382 MAT- ELEC-6.4.3 Routine maintenance of transformer, 1 No 4950
including testing of insulation resistance,
04062 oil break down strength. Reconditioning /
replacement of silicazel, cleaning of
transformer and topping upto oil level if
required (extra cost will be paid for oil).

131
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
383 MAT- ELEC-6.4.4 Testing of Transformer oil for 1 No 660
04063 dielectric breakdown strength.

384 ELEC-6.4.5 Removing the existing transformer from the plinth / Pole and refixing the
standby transformer of following capacity including connections etc.,
complete………….

MAT- a up to 315 KVA 1 No 3850


04064
MAT- b 500 / 1000 KVA 1 No 4950
04065
385 ELEC-6.4.6 Replacing old and unserviceable gasket of top cover plate of transformer
having following capacity. -…………

MAT- a up to 315 KVA 1 No 825


04066
MAT- b 500 / 1000 KVA 1 No 1100
04067
386 ELEC-6.4.7 Replacing old and unserviceable gasket of bushing for the following
Transformer capacity. -………….

MAT- a up to 315 KVA HT, 1 No 385


04068
MAT- b 500 / 1000 KVA HT, 1 No 825
04069
MAT- c up to 315 KVA LT, 1 No 990
04070
MAT- d 500 / 1000 KVA LT, 1 No 1650
04071
387 ELEC-6.4.8 Replacement the H T / L. T burntout winding coils of distribution
transformer including rewinding, varnishing and vaccuming etc.,duly
retaining the removed burnt winding coils by the Contractor / Firm- …….
MAT- a For copper coils 1 Kg 660
04072
MAT- b For aluminium coils 1 Kg 440
04073
387 MAT- ELEC-6.4.9 Insulating HT / LT copper / aluminium 1 Kg 358
04074 coils for Transformers.

388 ELEC-6.4.10 Painting to transformer with 2 coats Zinchromate red oxide duly scraping
existing paint followed by 2 coats of hammerton grey paint etc.,
complete. -……….

MAT- a Upto 500 KVA 1 No 3850


04075
MAT- b 630 / 1000 KVA 1 No 4950

132
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

04076
389 ELEC-6.4.11 Replacing ……….. for distribution Transformer by new
one.

MAT- a H.T bushing 1 No 385


04077
MAT- b H.T bushing with metal parts 1 No 440
04078
MAT- c L.T bushing Upto 315 KVA 1 No 220
04079
MAT- d L.T bushing 500 / 1000 KVA 1 No 275
04080
MAT- e L.T bushing rod with metal parts up 1 No 550
04081 to 315 KVA

MAT- f L.T bushing rod with metal parts 1 No 2035


04082 500/1000 KVA

390 ELEC-6.4.12 Drying the repaired transformer with appropriate heat / air of following
capacity of transformers. ……..-

MAT- a Upto 315 KVA 1 No 4840


04083
MAT- b 500 / 1000KVA 1 No 6050
04084
391 ELEC-6.4.13 Loading, transportation and Unloading of transformer from site to
Workshop or vice verse. ………

MAT- a Upto 500 KVA 1 No 4950


04085
MAT- b 630 / 1000 KVA 1 No 7700
04086
392 MAT- ELEC-6.4.14 Supply of new and tested transformer 1 Ltr 132
04087 oil as per IS-335 - 1972 (per Ltr)

393 ELEC-6.4.15 Filteration of transformer oil as per ISS specifications filters to dielectric
strength above 40KV ……..

MAT- a at site. (per Ltr) excluding 1 Ltr 11


04088 transportation

MAT- b at workshop (per Ltr) 1 Ltr 8


04089
6.5 OVERHEAD LINES& LINE
MATERIALS
394 ELEC-6.5.1 Supply and transportation of ………….PSCC Poles

MAT- a 8.0 Mtr ,Working load-140 Kgs 1No 2365


04090

133
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b 8.0 Mtr ,Working load-200 Kgs 1No 2503


04091
MAT- c 9.1 Mtr ,Working load-280 Kgs 1No 4565
04092
395 ELEC-6.5.2 Supply and transportation of 9 mtr length ………….RS Joist Poles

MAT- a 150 x 75 mm(Wt of the pole-140 Kgs) 1No 9460


04093
MAT- b 175 x 85 mm(Wt of the pole-215Kgs) 1No 14575
04094
MAT- c 150 x 150 mm(Wt of the pole-333 1No 22550
04095 Kgs)

396 ELEC-6.5.3 Supply and errection of GI stay set of dia……... including stay clamps ,
turn buckle and GI stay wire tight end through strain insulator including
excavation of pit and cc work etc.,complete
MAT- a 20mm,2.4 mtr long stay rod and 1 set 2035
04096 anchor plate 380mmx380mmx6.4mm

MAT- b 16mm,1.8 mtr long stay rod and 1 set 1540


04097 anchor plate 380mmx380mmx6.4mm

397 ELEC-6.5.4 Supply and fixing of 11KV -V- cross arms with ……………...duly welded
with necessary clamping arrangements etc., complete

MAT- a 75x40 mm MS channel including 4 1 No 1320


04098 nos 50 x 50 x6 mm packing plates (9
Kgs)
MAT- b 65 x65 x6 MS angle (8.2 Kgs) 1 No 935
04099
398 ELEC-6.5.5 Supply and fixing of LT 3 phase 4 wire cross arm of length 3' 8"
with……. and necessary clamping arrangements ,cutting ,drilling and
welding etc., complete

MAT- a 50 x 50 x6 mm MS angle ( wt 5.75 1 No 457


04100 Kgs)

MAT- b 65 x65 x6 MS angle (wt 7 Kgs) 1 No 539


04101
399 ELEC-6.5.6 Supply and fixing of LT 3 phase 5 wire cross arm of length 4' 5" with…….
and necessary clamping arrangements ,cutting ,drilling and welding etc.,
complete
MAT- a 50 x 50 x6 mm MS angle ( wt 1 No 589
04102 7.30Kgs)

MAT- b 65 x65 x6 MS angle (wt 9.60 Kgs) 1 No 743


04103

134
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
400 MAT- ELEC-6.5.7 Supply and fixing of LT single phase 3 wire cross 363
04104 arm with 50 x 50 x6 mm MS angle of 2' 5" ( wt 4.20
Kgs ) and necessary clamping arrangements ,cutting
,drilling and welding etc., complete

401 MAT- ELEC-6.5.8 Supply and fixing of 11 KV pin 220 200


04105 Insulator (IS 731/1971 ) with minimum
creepage distance of 300 mm on
existing cross arm including all
accessories like Hot dip GI spindle
and nuts etc.,
402 ELEC-6.5.9 Supply and fixing of ……... LT pocelain pininsulator as per IS 1447-1997
suitable for working voltage 1100 V including all accessories like Hot dip
GI spindle and nuts etc.,

MAT- a 100 x 65 mm each 88


04106
MAT- b 100 x 85 mm each 99
04107
403 ELEC-6.5.10 Supply and fixing of ……... LT pocelain shackle insulator as per IS 1443-
1979 suitable for working voltage 1100 V including all accessories like
Hot dip GI spindle and nuts etc.,

MAT- a 75 x 90 mm each 154


04108
MAT- b 100 x 110 mm each 187
04109
404 MAT- ELEC-6.5.11 Supply and fixing of distribution type each 2750
04110 lightning arrester 11 KV 5 kA as per IS
3070 with mounting base on the
existing DP structure
405 MAT- ELEC-6.5.12 Supply and fixing of 100 A 11 KV each 6050
04111 Horn Gap fuse set as per IS 9385 on
existing DP structure with 6 nos 24 KV
/22 KV post Insulators( IS 5350, Hot
dipped Hard ware, fuse wire of
required size etc., complete
406 MAT- ELEC-6.5.13 Supply and fixing of 11 KV danger each 110
04112 plates on the existing poles

407 MAT- ELEC-6.5.14 Supply and fixing of 11 KV ,400 A 3 each 19800


04113 phase central post rotating double
break type AB switch(isolator) as per
IS 9921) without earth blade,gang
operated ,Hozizontal type,operating
mechanism with GI spring loaded
reverse loop type fixed contact,solid
HD electrolytic copper tubular moving
contact with silver/Nicle plated at end
points,9 Nos post insulators of 12
Kv(IS 2594 and IS 5350) ,Hot Dip

135
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

galvenizing hardware,GI pipe,Nuts


and bolts etc., complete.,

408 ELEC-6.5.15 Supply and Transportation of Over Head …………. Conductor as per IS
398 (PART - II) : 1996

a 7/3.55 ACSR Rabbit (214 Kg/KM) 1KM

b 7/2.59 ACSR weasel (128 Kg/KM) 1KM

c 7/2.11 ACSR squirrel (85 Kg/KM) 1KM

MAT- d 100 sqmm AAA 1KM 56048


04114
MAT- e 55 sqmm AAA 1KM 32439
04115
MAT- f 34 sqmm AAA 1KM 19454
04116
409 ELEC-6.5.16 Supply and errecting fencing section 1 No As per DATA
having size 2045 mt height from
ground level and 1.2 mt width by
using angle iron size 50 x50 x6 mm
errected in cc foundation 15 x15x40
cm deep . The section of the frame
shall be fitted with flat iron support of
size 25 x 6 mm on top , bottom an
dmid way and chain link jolley of 3.26
mm dia /10 SWG GI hard wire mesh
of 50 x50 mm to the angle iron at
every distance of 30 cm , by iron
studs complete duly painted with one
coat of red oxide and 2 coats of
aluminium paint,

136
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
410 ELEC-6.5.17 Supply and errecting double leaf 1 No As per DATA
hinged door each 150 cm in width and
180 cm in height using 40 mm dia B
grade ISI mark GI pipe from all 4
sides with necessary bends and cross
supports of angle iron 45 X45 X5 mm
with the door leaf covered with chain
links jolley 50 X 50 mm made from
3.26 mm dia/10 SWG Gi wire with
necessary flat iron covering all round
with necessary no of spikes of size 10
mm dia at top and bottom at 150 mm
apart to match the height of fencing.
The door shall have latches and side
channel of 100 X50 X5 mm regidly
welded for providing locking
arrangement Godrej/Navtal make
medium size lock with duplicate keys,
fencing completely errected and
painted with anti corrosive red oxide
paint and 2 coats of prescribed
enamel paint/silver paint. The
Channel iron of size 150X75 mm by
2.5 mtr long shall be provided and
errected at both sides of gate.
411 ELEC-6.5.18 Supply and errecting 50 X50X6 mm 1 No As per DATA
angle iron corner support 0.5 mt way
from the fence supports fixed at the
middle fencing frame and other side in
cc foundation 15 X15X 40 cm
complete duly painted with 1 coat of
red oxide and 2 coats of alluminum
paint.
412 ELEC-6.5.19 Providing and spreading HBG metal of size 40 mm As per DATA
size for 100 mm depth above the ground level.

MAT- ELEC-6.5.20 Providing transformer plinth 1.2 x 1.2 1 No 11000


05548 x 1.5 mtr in size with necessary
excavation in ground at the bottom
with 150mm thick 1:2:4 cement
concrete raft at the bottom and top
and 225mm thick wall constructed in
stone masonry and remaking hallow
portion shall be filled with stone chips
duly plastered 20mm thick outsides
including watering etc., complete.
MAT- ELEC-6.5.21 Providing CTPT plinth 600mm x 1 No 6600
05549 600mm x 2.1 mtr in size with
necessary excavation in ground at the
bottom with 150mm thick 1:2:4
cement concrete raft at the bottom
and top duly plastered 20mm thick
outsides including watering etc.,
complete.
6.6 LIGHTENING PROTECTIVE

137
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

SYSTEM

Advanced LPS

MAT- ELEC-6.6.1 a Supply of ESE Air Terminal of 1 No 104500


05550 external wide area of protection
system based on proactive Early
Steamer Emission (ESE)
Technology manufactured in
accordance with NFC 17-102:2011,
is made of high-quality, non corrosive
and weather resistant XL-304
Stainless Steel Having triggering
advance t = 30µs,
Protection Radius ranging from 48
Meters in Level-I to 71 Meters in
Level-IV when installed on a 5
Meters Mast. ESE terminal is capable
to withstand Current
Impulses of 40kA (5 Shots of 8/20µs
wave shape) and having capturing rod
dia of 25mm.
Makes : As per list of recommended
brands.
MAT- ELEC-6.6.1 b Supply of ESE Air Terminal of 1 No 110000
05551 external wide area of protection
system based on proactive Early
Steamer Emission (ESE)
Technology manufactured in
accordance with NFC 17-102:2011,
is made of high-quality, non corrosive
and weather resistant XL-304
Stainless Steel Having triggering
advance t = 50µs,
Protection Radius ranging from 68
Meters in Level-I to 95 Meters in
Level-IV when installed on a 5 Meters
Mast. ESE terminal is capable to
withstand Current
Impulses of 40kA (5 Shots of 8/20µs
wave shape) and having capturing rod
dia of 25mm.
Makes : As per list of recommended
brands.

138
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
413 MAT- ELEC-6.6.1 c Supply of ESE Air Terminal of 1 No 125400
04117 external wide area of protection
system based on proactive Early
Steamer Emission (ESE)
Technology manufactured in
accordance with NFC 17-102:2011,
is made of high-quality, non corrosive
and weather resistant XL-304
Stainless Steel Having triggering
advance t = 60µs,
Protection Radius ranging from 79
Meters in Level-I to 107 Meters in
Level-IV when installed on a 5
Meters Mast. ESE terminal is capable
to withstand Current
Impulses of 40kA (5 Shots of 8/20µs
wave shape) and having capturing rod
dia of 25mm.
Makes : As per list of recommended
brands.

414 MAT- ELEC-6.6.2 Installation and commissioning of 1 No 31900


04118 advanced lighting protection systems
which includes
1. Laying of CC Bed
2. Installation of Lighting Rod
3. Laying of Down conductor
4. Installation of Counter
5. Installation of GI Mast with stay
wire.
6. Installation of Earth Electrodes
7. Interconnection between the
Electrodes
8. Termination of down conductor to
earth bus etc
complete.

415 MAT- ELEC-6.6.3 Supply of 6 Digit 1 No 16500


04119 Electronic/Mechanical counter
Makes : As per list of recommended
brands.

416 MAT- ELEC-6.6.4 Supply of G.I mast of 5 Meters length, 1 Set 6600
04120 50 mm Dia, with FRP Collar
(Insulating Bush) Base Plate &
Complete Fitting Accessories with
Supporting Guy Wire (Stay Wires) and
all fitting accessories
418 MAT- ELEC-6.6.5 Supply of IEC 62561-7 compliant Eco- 1 No 2420
04122 friendly, Maintenance free, anti-
corrosive, lead-free, super conductive,
mineral based high-grade earthing
compound, To enhance soil
conductivity. With resistance <0.12
ohms-meter, Sulphur Free, Should be

139
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

tested as per IEC-62561-7 for


resistance Toxic Elements, Leachable
elements etc. 25 Kg Bag
Makes : As per list of recommended
brands.
419 MAT- ELEC-6.6.6 Supply of Bentonite Moisture 1 No 187
04123 Retaining Powder
30 Kg Bag
420 MAT- ELEC-6.6.7 Supply of Concrete Earth Pit of 1 No 1650
04124 Dimensions: Width: 320 mm, Length:
320 mm, Height: 192mm, Weight 30
Kgs, Load bearing Capacity: 5000
Kgs
CONVENTIONAL LPS AS PER
IS/IEC 62305
Air Terminal

421 MAT- ELEC-6.6.8 Supply, installation, testing and 1 RM 99


04125 commissioning of 8 mm Aluminum
Round Conductor complete as per
requirements of DIN EN 50164-2
(VDE 0185 part 202) & VDE 0185-305
(IS/IEC 62305)
422 MAT- ELEC-6.6.9 Supply, installation, testing and each 55
04126 commissioning of Roof conductor
holder for parapet- Polyamide
Conductor holder: With M8 female
thread or diameter 7mm, M8 Screw to
connect the conductor holder.
Weather and temperature resistant
from -35 to +90 degree Celsius
tested. Conductor holder @ 1 meter
distance
423 MAT- ELEC-6.6.10 Supply, installation, testing and each 143
04127 commissioning of Polyamide roof
cable holder for flat roof:
DIN 48829 Form B1. Closed form with
bottom. Filling weight 1Kg (frost-
resistant concrete). Sleeve from
polyethylene, black @ 1 meter
distance.
424 MAT- ELEC-6.6.11 Supply, installation, testing and each 1815
04128 commissioning of Fang Fix Junior
system - Inclusive of Al intrception rod
of 1Mtr length(10mm dia ) , Quick
mounting of the interception rod in the
base using plug technology
425 MAT- ELEC-6.6.12 Supply, installation, testing and each 145
04129 commissioning of cross universal
connector: For T and cross
connection, to route vertical down
conductor /mesh formation made of
hot dipped galvanised iron with

140
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

necessary screws etc as required.


Installed with 4 hexagonal bolts
M8*25 with M8 hexagonal nuts

426 MAT- ELEC-6.6.13 Supply, installation, testing and each 435


04130 commissioning of expansion piece
with connector: For equalising
temperature related length changes.
Necessary on conductors length over
20 meters. For round conductor Rd
8/ALU.Connector: For T cross and
parallel connectors. Quick installation
using hexagonal bolt M10X30 high-
grade hot dip galvanised. Conforms to
the requirements according to DIN
VDE 0185-305 (IS-IEC
62305)(2nos/expansion piece ).
DOWN CONDUCTOR

427 MAT- ELEC-6.6.14 Supply, installation, testing and 1 RM 99


04131 commissioning of 8 mm Aluminum
Round Conductor complete as
specified in drawing & Meets the
requirements of DIN EN 50164-2
(VDE 0185 part 202) & VDE 0185-305
(IS/IEC 62305)
428 MAT- ELEC-6.6.15 Supply, installation, testing and each 55
04132 commissioning of Roof conductor
holder for parapet- Polyamide
Conductor holder: With M8 female
thread or diameter 7mm, M8 Screw to
connect the conductor holder.
Weather and temperature resistant
from -35 to +90 degree Celsius
tested. Conductor holder @ 1 meter
distance
429 MAT- ELEC-6.6.16 Supply, installation, testing and each 341
04133 commissioning of Test Joint (Folding
Clamp) suitable to connect 8mm
round conductor and max by 30x3
mm GI strip as specified in drawing
and directed by Engineer
430 MAT- ELEC-6.6.17 Supply, installation, testing and each 18150
04134 commissioning of Lightnig counter -
To count no of lightning strike & it can
record the date and time of the
lightning incident also tested as per
IEC 62561-6.
6.7 EARTHING

141
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
431 MAT- ELEC-6.7.1 Providing earth electrode of low 1 No 10450
04135 carbon steel rod, UL listed of 17.2 mm
dia, 3 Mtr long, coated with copper of
254 microns thickness, CPRI tested
for short time current withstand test of
25 kA, coating thickness,
environmental test (Salt Mist Test),
Bend test, Tensile strength, Yield /
tensile ratio, Electrical Resistivity test,
complete with clamps and 2 bags of
Earthplus ULTRA high grade earthing
compound IEC 62561-7 complaint
Eco-friendly, Maintenance free, anti
corrosive, lead-free, super conductive,
mineral based high-grade earthing
compound, to enhance soil
conductivity. With resistance <0.20
ohms-meter, should be leach proof &
sulphur free complete with earth
inspection chamber of dimensions :
Width : 320 mm x 320 mm, Height :
192 mm, Weight : 30 Kgs, Load
bearing capacity :
5000 Kgs
432 MAT- ELEC-6.7.2 Providing earthling as per IS 3043 1 No As per DATA
04136 with perforated 3 mtr long 40 mm dia
B class GI pipe including all
accessories like nuts bolts
reducer,nipple, wire meshed funnel
andCCfinished chamber covered with
hinged type with CI cover ,CI frame of
size 300 X 300 mm and embodying
the pipe complete with alternate
layers of salt and coke
/charcoal/bentonite powder testing
earth resistance as required etc.,
complete
433 MAT- ELEC-6.7.3 Providing earthling as per IS 3043 1 No As per DATA
04137 with GI earth plate of size 600 x600 x
6 mm by embodying 3 to 4 mtr nelow
the ground level with 40 mm dia GI B
class perforated pipe including all
including all accessories like nuts
bolts reducer,nipple, wire meshed
funnel andCCfinished chamber
covered with hinged type with CI
cover ,CI frame of size 300 X 300 mm
and embodying the pipe complete
with alternate layers of salt and coke
/charcoal/bentonite powder testing
earth resistance as required etc.,
complete

142
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
434 MAT- ELEC-6.7.4 Providing earthing as per IS 3043 1 No As per DATA
04138 with copper earth plate of size 600 x
600 x 3.15 mm by embodying 3 to 4
mtr below the ground level with
40mm dia 'B' Class G.I Pipe by
exacavating a pit to a depth of 3 to 4
Mtr in all soils for Sophisticated
Electronic equipment as per National
Electric Code and earth connection
from electrode Copper strip of 25mm
x 5mm x 200mm length to be bolted
with nut bolts to G.I.pipe including
25mm x 3mm copper strip of 6Mtrs
length connected from plate to Copper
strip including filling with 20Kg Salt
and 40Kg Charcoal or 40Kg bentonite
powderincluding all accessories like
nuts bolts reducer,nipple, wire
meshed funnel andCCfinished
chamber covered with hinged type
with CI cover ,CI frame of size 300 X
300 mm ,testing earth resistance as
required etc., complete
435 MAT- ELEC-6.7.5 Providing independent earthing for 1 No 8250
04139 Important equipment with 100mm dia
Heavy gauge C.I ( Cast iron ) pipe
with Flange 2.5m long enclosed in
C.C/ brick massonry chamber of
450m x 450m x 400mm with R.C.C.
Slab cover duly providing staggered
holes filling with salt and charcoal
from the bottom of the pipe giving
earth connection from electrode
through G.I strip of 40 x 6mm x
200mm length with all accessories
and labour charges complete, as per
IS specifications 732/1982 (Part II)
EARTH CONDUCTORS

436 ELEC-6.7.6 Supply and laying of following sizes Earth wire/Strip in horizontal
/Vertical run in Ground/surface/Recess including,
revitting,soldering,saddles,making connection etc as required
MAT- a 6 SWG Copper wire(0.16 Kgs/1 Mtr) 1 Mtr 108
04140
MAT- b 8 SWG Copper wire(0.1155Kgs/1Mtr) 1 Mtr 78
04141
MAT- c 10 SWG Copper wire(0.075Kgs/1Mtr) 1 Mtr 51
04142
MAT- d 6 SWG GI wire(0.192 Kgs/Mtr) 1 Mtr 14
04143
MAT- e 8 SWG GI wire(0.104Kgs/1Mtr) 1 Mtr 8
04144

143
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- f 10 SWG GI wire(0.067Kgs/1Mtr) 1 Mtr 4


04145
MAT- g 20mm x 3mm Copper 1 Mtr 359
04146 Flat(0.529Kgs/1Mtr)

MAT- h 25mm x 3mm Copper Flat 1 Mtr 449


04147 (0.663Kgs/1Mtr)

MAT- i 32 mm x 6mm Copper Flat(1.9 1 Mtr 1288


04148 Kgs/Mtr)

MAT- j 50 mm x 6mm Copper Flat 1 Mtr 1817


04149 (2.680Kgs/1Mtr)

MAT- k 25mm x 3mm GI Flat(0.656 Kgs/Mtr) 1 Mtr 46


04150
MAT- l 25mm x 6mm GI Flat (1.18Kgs/1Mtr) 1 Mtr 83
04151

MAT- m 32 mm x 6mm GI Flat(1.6 kgs/Mtr) 1 Mtr 116


04152
MAT- n 50 mm x 6mm GI Flat(2.5 Kgs ?mtr) 1 Mtr 176
04153
SECTION 7

7.0 LOCAL AREA NETWORK

437 ELEC-7.1.1 Supply,laying ,testing and commisioning of 4-pair, Cat6 Solid (Third
party ETL Intertek tested 600 MHZ above) to support 1Gbps with Cross
(+) filler pair seperator & PVC sheath 23 AWG, STP/UTP Cable , Meets
or exceeds ANSI/TIA-568-C.2 and UL Listed &RoHS Compliant in the
existing raceways /pvc conduits including making connections to
information outlets and patch panels with ferruling at both ends for
identifiation with necessary tools for punching stripping crimping and
testing required etc., complete.
Makes : As per list of recommended brands.
MAT- a 6 UTP cable RM 35
04154

MAT- b 6 STP cable RM 48


05553

438 MAT- ELEC-7.1.2 Supply installation testing and each 825


04155 commisioning of 2nos of Cat6
Tooless builtin crimping mechanism
Information Outlet with Dust Cover
Exceed ANSI/TIA-568-C.2 and
ISO/IEC 11801 standards with
2module face plate for Category 6
component performance &
Compatible to T568A,T568B wiring

144
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

pattern and UL-940V0 Rated Plastic


&RoHS Compliant
Makes : As per list of recommended
brands.

439 MAT- ELEC-7.1.3 Supply installation testing and each 429


04156 commisioning of1no of Cat6 Tooless
builtin crimping mechanism
Information Outlet with Dust Cover
Exceed ANSI/TIA-568-C.2 and
ISO/IEC 11801 standards with
1module face plate for Category 6
component performance &
Compatible to T568A,T568B wiring
pattern and UL-940V0 Rated Plastic
&RoHS Compliant
Makes : As per list of recommended
brands.
440 ELEC-7.1.4 Supply installation testing and commisioning of 4 pair 23AWG Cat6 UTP
,flexible ,double ended patch cords along with 2 nos of RJ 45 connectors
with strain relief boots Compatible to T568A,T568Bspecifications
including making connections to information outlets
Makes : As per list of recommended brands.
MAT- a 1mtr/3 ft each 204
04157
MAT- b 2mtr/7 ft each 242
04158
MAT- c 3 mtr/10 ft each 275
04159
441 MAT- ELEC-7.1.5 Supply installation testing and each 297
04160 commisioningof Single Mode LC
Pigtails LSZH 1mtr for fibre core
connectivity
Makes : As per list of recommended
brands.
442 MAT- ELEC-7.1.6 Supply installation testing and each 407
04161 commisioningof Single Mode SC
Pigtails LSZH 1mtr for fibre core
connectivity.
Makes : As per list of recommended
brands.
443 MAT- ELEC-7.1.7 Supply installation testing and each 308
04162 commisioningof Single Mode LC
Pigtails LSZH 2mtr for fibre core
connectivity.
Makes : As per list of recommended
brands.

145
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
444 MAT- ELEC-7.1.8 Supply installation testing and each 429
04163 commisioningof Single Mode SC
Pigtails LSZH 2mtr for fibre core
connectivity.
Makes : As per list of recommended
brands.
445 ELEC-7.1.9 Supply installation testing and commisioning of Indoor
multimode[62.5/125um ] glass Fiber Optic Cable as per
latest ammendments of TIA /EIA 568B.3 , GR 409
CORE / UL listed NEC 770 Standards in existing
Raceways/PVC Conduits/ slotted channels including making
Terminations to active passive equipments with ferruling at both ends for
identification with necessorry tools for Terminations and testing required.
Makes : As per list of recommended brands.
MAT- a 4 fiber 70
04164
MAT- b 6 fiber 76
04165
MAT- c 12 fiber 105
04166
446 ELEC-7.1.10 Supply installation testing and commisioning Outdoor, steel tape
armoured multimode[62.5/125um ] glass Fiber Optic Cable as per latest
ammendments of TIA /EIA 568B.3 , GR 20 CORE/ UEC 794-1/ EN
187000 Standards in existing MSPVC Conduits/ hume pipe including
making terminations to active passive equipments with ferruling at both
ends for identification with necessorry tools for Terminations and testing
required.
Makes : As per list of recommended brands.
MAT- a 4 fiber 72
04167
MAT- b 6 fiber 79
04168
MAT- c 12 fiber 108
04169
446 MAT- ELEC-7.1.11 Supply ,Installation and Testing and mtr 1011
04170 commissioning of indoor 1 pair
multimode [62.5/125um ] glass Fiber
Optic Patch Cords of One mtr length
as per latest ammendments of TIA
/EIA 568B.3 and IEC 794 Standard
Specifications including ST II /
SC/FC/MT/PC connectors at both
ends as per requirements.
Makes : As per list of recommended
brands.

146
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
447 ELEC-7.1.12 Supply ,Installation Testing and commisioning of 19 " Rack
mounted/surface mounted aluminium / CRS powder coated multimode
glass Fiber Optic Cable Patch panel/ LIU(upgradable to intelligent panels
with use of sensor strips) along with cable tray/ fiber management
system , adapters for ST II/ SC/FC/MT/PC connections including making
connections to active / passive equipments with ferruling at both ends
for identification with necessary tools for Terminations and testing
required.
Makes : As per list of recommended brands.
MAT- a 8 Ports 1 No 6050
04171
MAT- b 12 Ports 1 No 7920
04172
MAT- c 24 Ports 1 No 14988
04173
MAT- d 36 Ports 1 No 16940
04174
448 ELEC-7.1.13 Supply , Installation, Testing and Comissioning of Rack
mounted 19", Cat 6 UTP,1.5-1.6 MM CRS chasis ,
powder coated Modular Patch Panels (upgradable to
intelligent panels with use of sensor strips) with
collapsible shutters on jacks to support latest
ammendments of TIA / EIA Cat 6 Specifications in
Existing Communication Rack along with necessory
connections of Cat 6 UTP Cables, With Rear Cable
management trays and clamps.
Makes : As per list of recommended brands.
MAT- a 6 Ports 1 No 3190
04175
MAT- b 12 Ports 1 No 3960
04176
MAT- c 18 Ports 1 No 4950
04177
MAT- d 24 Ports 1 No 6050
04178
449 ELEC-7.1.14 Supply , Installation, Testing and Comissioning of Wall
mounted Communication rack in two sections viz rear
wall mount Section and hinged front section with glass
doors, swing handles ,lock , Top and Bottom Cable
entries,Supports for mounting rack on wall , Cable
managers, Fan tray with 2 x 230 Volt fans, Equipment
mounting hardware, wire managers , power supply box
for supplying power to hubs, fans etc along with earth
continuity kit, Mcb, indicator, moulded power supply
cable, Blank panels , sliding shelves etc.
Makes : As per list of recommended brands.
MAT- a 6 U(44 mm ) wall mounted 1 No 5148
04179

147
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b 9 U(44 mm ) wall mounted 1 No 6050


04180
MAT- c 12 U(44 mm ) wall mounted 1 No 7106
04181
MAT- d 15 U(44 mm ) wall mounted 1 No 8052
04182
450 ELEC-7.1.15 Supply , Installation, Testing and Comissioning of Floor
mounted Communication rack in two sections viz rear
Steel Door and hinged front section with glass doors,
swing handles ,lock on both doors, Top and Bottom
Cable entries with gland plates ,Castor with brakes , 7
no Cable managers, 1 no Fan tray with 2 x 230 Volt
fans, Equipment mounting hardware, wire managers ,
power supply box for supplying power to hubs, fans etc
along with earth continuity kit, Mcb, indicator, moulded
power supply cable, Blank panels of 1u / 2 u , sliding
shelves .Frame of communication rack should be made
of heavy grade Aluminum profile PS grey painted and
panels should be made from CRCA steel 18 swg RS
Beige painted .
Makes : As per list of recommended brands.
MAT- a 22 U (44 mm ) Floor Standing Rack 1 No 22550
04183
MAT- b 27 U (44 mm )Floor Standing Rack 1 No 25300
04184
MAT- c 37 U (44 mm )Floor Standing Rack 1 No 35200
04185
MAT- d 42 U (44 mm )Floor Standing Rack 1 No 45980
04186 800WX1000D

MANAGEBLE NET WORK


SWITCHES
451 MAT- ELEC-7.1.16 Supply ,Installation ,Testing and 1 No 14300
04187 Commissioning of Small Business 24
port Gigabit Managed Switch.
Makes : As per list of recommended
brands.
452 MAT- ELEC-7.1.17 Supply ,Installation ,Testing and 1 No 27280
04188 Commissioning of Small Business 48
port Gigabit Managed Switch.
Makes : As per list of recommended
brands.,
453 MAT- ELEC-7.1.18 Supply & Fixing of Cisco small 1 No 14850
04189 business 8 port Gigabit POE
Managed Switch.
Makes : As per list of recommended
brands.

148
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
454 MAT- ELEC-7.1.19 Supply & Fixing of Cisco small 1 No 27500
04190 business 24 port Gigabit POE
Managed Switch .
Makes : As per list of recommended
brands.
455 MAT- ELEC-7.1.20 Supply ,Installation ,Testing and 1 No 78650
04191 Commissioning of Small Business 24
port Gigabit Managed Switch
Makes : As per list of recommended
brands.
456 MAT- ELEC-7.1.21 Supply , Installation, Testing and 1 No 57200
04192 Comissioning of Layer2, Catalyst
2960 Plus 24 port, 10/100+2T/SFP
LAN base Manageble Net work
switch.
Makes : As per list of recommended
brands.
457 MAT- ELEC-7.1.22 Supply , Installation, Testing and 1 No 112200
04193 Comissioning of Layer2, Catalyst
2960 Plus 48 port, 10/100+2T/SFP
LAN base Manageble Net work
switch.
Makes : As per list of recommended
brands.
458 MAT- ELEC-7.1.23 Supply , Installation, Testing and 1 No 112200
04194 Comissioning of Layer2, Catalyst
2960 Plus 24 port, POE
10/100+2T/SFP LAN base Manageble
Net work switch.
Makes : As per list of recommended
brands.

459 MAT- ELEC-7.1.24 Supply , Installation, Testing and 1 No 198000


04195 Comissioning of Layer2, Catalyst
2960 Plus 48 port, POE
10/100+2T/SFP LAN base Manageble
Net work switch.
Makes : As per list of recommended
brands.

460 MAT- ELEC-7.1.25 Supply , Installation, Testing and 1 No 167750


04196 Comissioning of Layer2, Catalyst
2960 Plus 24 port, GigE LAN base
Manageble Net work switch.
Makes : As per list of recommended
brands.
461 MAT- ELEC-7.1.26 Supply , Installation, Testing and 1 No 292600
04197 Comissioning of Layer2, Catalyst
2960 Plus 48 port, GigE LAN base
Manageble Net work switch.
Makes : As per list of recommended
brands.

149
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
462 MAT- ELEC-7.1.27 Supply & Fixing of WIFIAcess point 1 No 24750
04198 with mounting accessories
etc.,complete .
Makes : As per list of recommended
brands.
7.2 RACEWAYS AND JUNCTION
BOXES
463 ELEC-7.2.1 Supply of …………G I Raceways of 2mm thick with top cover and
required hard ware etc complete.

MAT- a 100mm x 38mm 1 Mtr 490


04199
MAT- b 150mm x 38mm 1 Mtr 655
04200
MAT- c 300mm x 38mm 1 Mtr 1111
04201
MAT- d 100mm x 25mm 1 Mtr 462
04202
MAT- e 150mm x 25mm 1 Mtr 605
04203
MAT- f 300mm x 25mm 1 Mtr 1089
04204
464 ELEC-7.2.2 Supply of …………..G.I. Junction box of 2mm thick for direct acces to
cables at the inter section of Raceways.

MAT- a 172mm x 52mm 1 No 369


04205
MAT- b 222mm x 52mm 1 No 468
04206
MAT- c 372mm x 52mm 1 No 869
04207
7.3 COMPUTERS,PRINTERS AND
SCANNERS

150
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-7.3.1 Supply, Transportation and installation 1 No 72270


04208 of Desktop with fully loaded software
as desired, with the following
configuration.
1. Processor:Intel® Core™ i7-7700
Processor with Intel® HD Graphics
630 (3.6 GHz base frequency, up to
4.2 GHz with Intel® Turbo Boost
Technology, 8 MB cache, 4 cores)
Intel H110 Chipset
2. Memory: 8 GB DDR4-2400 SDRAM
(1 x 8 GB)
3. Hard drive 1 TB 7200 rpm SATA
4. HP Monitor : 18.5”/19.5" with TCO
7.0 or its equivalent in HP/Dell/Lenova
5. DVD:RW 9.5MM Optical Disk Drive,
1 audio line in; 1 audio line out; 1
HDMI; 1 RJ-45; 1 VGA; 4 USB 3.0; 4
USB 2.0
6. Operating Systems: Preloaded
Windows 10 professional 64 bit with
product key License.
7. Preloaded with latest version of
Antivirus Symantec/ McAfee / NOD32
/ eTrust / Avast Internet Security /
Kaspersky / Quickheal / eScan /
Msecure with following features:
Antivirus, Antispyware, Instrusion
Prevention Browser protection with
single management console with 3
year subscription with support
updates and patches.
8. Accessories: With required
connecting cables and driver media
should be supplied.
9. Warranty: 3 Year Standard On-Site
Comprehensive Hardware Warranty
(including O.S support, Spares-
Parts/Service/Labour/On-site)
Makes : As per list of recommended
brands.

151
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
465 MAT- ELEC-7.3.2 Supply, Transportation and installation 1 No 65285
04209 of Desktop with fully loaded software
as desired, with the following
configuration.
1. Processor:Intel® Core™ i5-7500
Processor with Intel® HD Graphics
630 (3.4 GHz base frequency with
Intel® Turbo Boost Technology, 6 MB
cache) Intel H110 Chipset
2. Memory: 8 GB DDR4-2400 SDRAM
(1 x 8 GB)
3. Hard drive 1 TB 7200 rpm SATA
4. HP Monitor : 18.5”/19.5" with TCO
7.0 or its equivalent in Dell/Lenova
5. DVD:RW 9.5MM Optical Disk Drive,
1 audio line in; 1 audio line out; 1
HDMI; 1 RJ-45; 1 VGA; 4 USB 3.0; 4
USB 2.0
6. Operating Systems: Preloaded
Windows 10 professional 64 bit with
product key License. However, the
product key should be mentioned in
the installation report at the time of
installation.
7. Preloaded with latest version of
Antivirus Symantec/ McAfee / NOD32
/ eTrust / Avast Internet Security /
Kaspersky / Quickheal / eScan /
Msecure with following features:
Antivirus, Antispyware, Instrusion
Prevention Browser protection with
single management console with 3
year subscription with support
updates and patches.
8. Accessories: With required
connecting cables and driver media
should be supplied.
9. Warranty: 3 Year Standard On-Site
Comprehensive Hardware Warranty
(including O.S support, Spares-
Parts/Service/Labour/On-site)
Makes : As per list of recommended
brands.
466 MAT- ELEC-7.3.3 Supply, Transportation and installation 1 No 11968
04210 of Printer
Features:
Print technology Laser
Duty cycle (monthly, letter) Up to 5000
pages
Recommended monthly page volume
250 to 2000
Duty cycle (monthly, A4) Up to 5000
pages print
Print speed black (normal, letter) Up
to 15 ppm
Print speed black (normal, A4) Up to
14 ppm

152
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Duplex printing Manual (driver support


provided)
PROCESSOR Processor speed 234
MHz
PAPER HANDLING Envelope feeder
No
Paper trays, maximum 1 (plus single-
sheet priority input slot)
Makes : As per list of recommended
brands.

467 MAT- ELEC-7.3.4 Supply, Transportation and installation 1 No 22550


04211 of All-in-One (Print, Copy, Scan) with
duplex, auto document feeder
features:
-Print Resolution 600 x 600dpi
-Print Speed (A4) 27ppm
-Auto Duplex Printing Standard
-Available Paper Size for Auto Duplex
Print A4, Letter, Legal (*1), Indian
Legal, Fulllscape
-COPY Copy Speed (A4) 27ppm
Maximum Number of Copies Up to
999 copies
Scan Type Colour Contact Image
Sensor
Scan Resolution Optical Up to 600 x
600dpi
Pull Scan Yes, USB and Network
Makes : As per list of recommended
brands.
468 MAT- ELEC-7.3.5 Supply, Transportation and installation 1 No 38489
04212 of Document Scanner
Features:
upto 30ppm/60ipm at 300dpi
paper size A8 to A4/Legal
256MB memory
upto 1200X1200 dpi resolution
50pages ADF input capacity
upto 3000 pgs daily duty cycle
USB 2.0 Host & Gigabit Lan Port
Makes : As per list of recommended
brands.
469 MAT- ELEC-7.3.6 Supply of 5 Pair telephone copper 100 Mtrs 2750
04213 wire.
Makes : As per list of recommended
brands.

470 MAT- ELEC-7.3.7 Supply of 100 pair MDF loaded with 1 No 3663
04214 2/10 Modular.
Makes : As per list of recommended
brands.

153
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
471 MAT- ELEC-7.3.8 Supply of 100 Pair raiser cable for 1 Mtr 385
04215 telephone .
Makes : As per list of recommended
brands.
472 MAT- ELEC-7.3.9 Supply of 10 Pair telephone Copper 1 Mtr 39
04216 wire.
Makes : As per list of recommended
brands.
473 MAT- ELEC-7.3.10 Supply of 20 Pair telephone Copper 1 Mtr 77
04217 wire.
Makes : As per list of recommended
brands.
474 MAT- ELEC-7.3.11 Supply of 50 Pair telephone Copper 1 Mtr 193
04218 wire.
Makes : As per list of recommended
brands.
475 MAT- ELEC-7.3.12 Supply of 10 pair Telephone 1 No 649
04219 distribution box with back mount
frame, krone connector, powder
coated metal body with lock and key
arrangement.
476 MAT- ELEC-7.3.13 Supply of 20 pair Telephone 1 No 990
04220 distribution box with back mount
frame, krone connector, powder
coated metal body with lock and key
arrangement.
477 MAT- ELEC-7.3.14 Supply of 50 pair Telephone 1 No 2063
04221 distribution box with back mount
frame, krone connector, powder
coated metal body with lock and key
arrangement.
478 MAT- ELEC-7.3.15 Supply of 200 pair Telephone 1 No 7876
04222 distribution box with back mount
frame, krone connector, powder
coated metal body with lock and key
arrangement.
EPABX SYSTEM

7.4 SMALL SYSTEM

154
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-7.4.1 Supply, Installation, testing and 1 No 95150


05554 Commissioning of IP Based digtal
Telephone (EPABX) system -----
complied with following specifications:
> IP @ Core, PCM/TDM, Non
blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and Ios)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt 8 Channel Auto Attendant
> Inbuilt Call Details Software with
search engine software
> 4 Analog Trunks
> 6 Digital Extensions
> 32 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Expandable to 64 Analog
Extensions or more
/ Makes : As per list of recommended
brands.
MAT- ELEC-7.4.2 Supply, Installation, testing and 1 No 104500
05555 Commissioning of IP Based digtal
Telephone (EPABX) system -----
complied with following specifications:
> IP @ Core, PCM/TDM, Non
blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and Ios)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt 8 Channel Auto Attendant
> Inbuilt Call Details Software with
search engine software
> 4 Analog Trunks
> 6 Digital Extensions
> 48 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Expandable to 64 Analog
Extensions or more
Makes : As per list of recommended
brands.

155
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-7.4.3 Supply, Installation, testing and 1 No 116380


05556 Commissioning of IP Based digtal
Telephone (EPABX) system -----
complied with following specifications:
> IP @ Core, PCM/TDM, Non
blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and Ios)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt 8 Channel Auto Attendant
> Inbuilt Call Details Software with
search engine software
> 4 Analog Trunks
> 1 ISDN PRI Module
> 6 Digital Extensions
> 48 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Expandable to 64 Analog
Extensions or more
Makes : As per list of recommended
brands.

MAT- ELEC-7.4.4 Supply, Installation, testing and 1 No 119900


05557 Commissioning of IP Based digtal
Telephone (EPABX) system -----
complied with following specifications:
> IP @ Core, PCM/TDM, Non
blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and Ios)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt 8 Channel Auto Attendant
> Inbuilt Call Details Software with
search engine software
> 4 Analog Trunks
> 6 Digital Extensions
> 64 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Expandable to 64 Analog
Extensions or more
Makes : As per list of recommended
brands.

156
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-7.4.5 Supply, Installation, testing and 1 No 130900


05558 Commissioning of IP Based digtal
Telephone (EPABX) system -----
complied with following specifications:
> IP @ Core, PCM/TDM, Non
blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and Ios)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt 8 Channel Auto Attendant
> Inbuilt Call Details Software with
search engine software
> 4 Analog Trunks
> 1 ISDN PRI Module
> 6 Digital Extensions
> 64 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Expandable to 64 Analog
Extensions or more
Makes : As per list of recommended
brands.
MAT- ELEC-7.4.6 Supply and installation of Analog 1 No 15950
05559 Extension Card (with Caller ID) 8
extensions.
MAT- ELEC-7.4.7 Supply and installation of Analog 1 No 20900
05560 Extension Card (with Caller ID) 16
extensions.
MAT- ELEC-7.4.8 Supply and installation of Analog 1 No 17710
05561 Trunk Card (with Caller ID) 4 trunks.

MAT- ELEC-7.4.9 Supply and installation of Analog 1 No 22000


05562 Trunk Card (with Caller ID) 8 trunks.

MAT- ELEC-7.4.10 Supply and installation of Digital 1 No 20570


05563 Extension Card for 8 digital
extensions:
MAT- ELEC-7.4.11 Supply and installation of Digital 1 No 34650
05564 Extension Card for 16 digital
extensions:
MAT- ELEC-7.4.12 Supply and installation of E1 Trunk 1 No 51975
05565 Card or PRI Card
30 ISDN PRI or R2 trunk channels.

7.5 LARGE SYSTEM 1 No

157
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-7.5.1 Supply, Installation, Testing and 1 No 262460


05566 Commissioning of IP Based digtal
Telephone (EPABX) system--
complied with following specifications:
> IP @ Core, PCM/TDM switching,
Non blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and IOs)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt Call Details Software with
search engine software
> 8 Analog Trunks
> 8 Digital Extensions
> 96 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Expandable to 220 Ports wired or
more at extra cost
Makes : As per list of recommended
brands.
MAT- ELEC-7.5.2 Supply, Installation, Testing and 1 No 397100
05567 Commissioning of IP Based digtal
Telephone (EPABX) system--
complied with following specifications:
> IP @ Core, PCM/TDM switching,
Non blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and IOs)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt Call Details Software with
search engine software
> 8 Analog Trunks
> 1 PRI Trunk module
> 8 Digital Extensions
> 128 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Expandable to 220 Ports wired or
more at extra cost
Makes : As per list of recommended
brands.

158
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-7.5.3 Supply, Installation, Testing and 1 No 478500


05568 Commissioning of IP Based digtal
Telephone (EPABX) system--
complied with following specifications:
> IP @ Core, PCM/TDM switching,
Non blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and IOs)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt Call Details Software with
search engine software
> 8 Analog Trunks
> 1 PRI Trunk module
> 8 Digital Extensions
> 160 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Inbuilt hotstandby for CPU and
PSU.
> Compatibility to run on DC -48v
source.
> Expandable to 220 Ports wired or
more at extra cost
Makes : As per list of recommended
brands.

MAT- ELEC-7.5.4 Supply, Installation, Testing and 1 No 666600


05569 Commissioning of IP Based digtal
Telephone (EPABX) system--
complied with following specifications:
> IP @ Core, PCM/TDM switching,
Non blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and IOs)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt Call Details Software with
search engine software
> 8 Analog Trunks
> 1 PRI Trunk module
> 16 Digital Extensions
> 224 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Inbuilt hotstandby for CPU and
PSU.
> Compatibility to run on DC -48v
source.
> Expandable to 400 Ports wired or
more at extra cost

159
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Makes : As per list of recommended


brands.
MAT- ELEC-7.5.5 Supply, Installation, Testing and 1 No 772200
05570 Commissioning of IP Based digtal
Telephone (EPABX) system--
complied with following specifications:
> IP @ Core, PCM/TDM switching,
Non blocking,
> Must Support PRI, E1, Analog
Junctions
> Must Support PC Console,
> Must support Mobile SIP (Android
and IOs)
> Must support Voice Mail
> Must support Card based GSM
> Inbuilt Call Details Software with
search engine software
> 8 Analog Trunks
> 1 PRI Trunk module
> 16 Digital Extensions
> 304 Analog Extensions
> 1 Digital Key Phone with minimum
16 Keys (Must work only on 2 wires)
> Inbuilt hotstandby for CPU and
PSU.
> Compatibility to run on DC -48v
source.
> Expandable to 400 Ports wired or
more at extra cost
Makes : As per list of recommended
brands.
MAT- ELEC-7.5.6 Supply and Installation of Analog 1 No 21890
05571 Extension Card (with Caller ID) 16
extensions.
MAT- ELEC-7.5.7 Supply and Installation of Analog 1 No 21890
05572 Trunk Card (with Caller ID) 8 trunks.

MAT- ELEC-7.5.8 Supply and Installation of Digital 1 No 21890


05573 Extension Card for 8 digital
extensions:
MAT- ELEC-7.5.9 Supply and Installation of Digital 1 No 35970
05574 Extension Card for 16 digital
extensions:
MAT- ELEC-7.5.10 Supply and Installation of E1 Trunk 1 No 54010
05575 Card or PRI Card
30 ISDN PRI or R2 trunk channels.
MAT- ELEC-7.5.11 Supply and Installation of IP CPU 1 No 39380
05576 card for redundancy purpose

MAT- ELEC-7.5.12 Supply and Installation of PSU card 1 No 23980


05577 for redundancy purpose

MAT- ELEC-7.5.13 Supply and Installation of Digital Key 1 No 9240


05578 Telephone with 2 line display, 10
programmable keys, handsfree

160
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

dialing.
MAT- ELEC-7.5.14 Supply and Installation of Digital Key 1 No 16170
05579 Telephone with 2 line display, 16
programmable keys, fully handsfree
talk back.
MAT- ELEC-7.5.15 Supply and Installation of IP Gateway 1 No 45650
05580 card for 8 channels

MAT- ELEC-7.5.16 Supply and Installation of IP Gateway 1 No 66000


05581 card for 16 channels

MAT- ELEC-7.5.17 Supply and Installation of SIP 1 No 4675


05582 extensions licenses pack (5 SIP
extensions)
MAT- ELEC-7.5.18 Supply and Installation of SIP 1 No 8195
05583 extensions licenses pack (10 SIP
extensions)
MAT- ELEC-7.5.19 Supply and Installation of IP phone 1 No 18480
05584 with POE.

MAT- ELEC-7.5.20 Supply and Installation of 4 port GSM 1 No 48180


05585 card

MAT- ELEC-7.5.21 Supply and Installation of Expansion 1 No 91300


05586 cabinet for 220 more extensions

MAT- ELEC-7.5.22 Supply and Installation of 100 Pair 1 No 14740


05587 MDF along with IPM

SECTION 8

8.1 MISCELLANEOUS ITEMS

479 MAT- ELEC-8.1.1 TW Seperators / Gutties 100 Nos 198


04223
480 MAT- ELEC-8.1.2 PVC Rawl Plugs 100 Nos 33
04224
481 MAT- ELEC-8.1.3 PVC Grips 100 Nos 33
04225
482 MAT- ELEC-8.1.4 U Nails 100 Nos 33
04226
483 MAT- ELEC-8.1.5 Alluminium Link Clips 100 Nos 33
04227
484 MAT- ELEC-8.1.6 50 mm G.I.Nut and Bolts. 1 Set 17
04228
485 MAT- ELEC-8.1.7 63 to 100 mm G.I.Nut and Bolts. 1 Set 28
04229
486 MAT- ELEC-8.1.8 50 mm 0 Gauge Nails 1 Doz 50
04230

161
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
487 MAT- ELEC-8.1.9 63 to 100 mm 0 Gauge Nails 1 Doz 79
04231
488 MAT- ELEC-8.1.10 Hard Coke 1 Kg 22
04232
489 MAT- ELEC-8.1.11 Salt 1 Kg 17
04233
490 MAT- ELEC-8.1.12 PVC Cleats 2 Way 100 Nos 358
04234
491 MAT- ELEC-8.1.13 PVC Cleats 4 Way 100 Nos 473
04235
492 MAT- ELEC-8.1.14 Binding Wire 1 Kg 66
04236
493 MAT- ELEC-8.1.15 PVC /cotton tape Role ( 8 Mtrs) 1 No 20
04237
494 MAT- ELEC-8.1.16 C.I.Knob 1 No 28
04238
495 MAT- ELEC-8.1.17 Stay tight set (Jum bracket 300 mm) 1 Pair 325
04239
496 MAT- ELEC-8.1.18 Stay clamp with bolts and Nuts) 1 Set 216
04240
497 MAT- ELEC-8.1.19 L.T.Guy insulator 1 No 83
04241
498 MAT- ELEC-8.1.20 12 / 15 MS plain rod fan hook 1 No 33
04242
499 MAT- ELEC-8.1.21 19 / 20 mm Steel tube fan down rod 1 Mtr 94
04243
500 MAT- ELEC-8.1.22 Consealed box PVC / MS with hook 1 No 110
04244 for fan

501 MAT- ELEC-8.1.23 Supply and fixing of Anchor fastner 1 No 88


04245 with fan hook / Providing MS Fan
hook with grouting and cement
plastering.

502 MAT- ELEC-8.1.24 Coil Earthing 1 No 83


04246
503 MAT- ELEC-8.1.25 Cable root Indicators of size 152mm 1 No 94
04247 round / 102mm x 102mm /
152mm x 152mm
504 MAT- ELEC-8.1.26 40 mm x 40 mm x 6 mm angle iron 1 Set 270
04248 with I bolt.

505 MAT- ELEC-8.1.27 Mild Steel Items 1 Kg 66

162
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

04249
506 MAT- ELEC-8.1.28 Acrylic Cover of size 4" x 7" for night 1 No 22
04250 lamps.

507 MAT- ELEC-8.1.29 TW / PVC Round Blocks 1 No 9


04251
508 MAT- ELEC-8.1.30 G.I.Funnel with Mesh 1/2" x 4" 1 No 88
04252
509 MAT- ELEC-8.1.31 Asbestos Sheet 1 Sq Mt 28
04253
510 MAT- ELEC-8.1.32 First Aid box 18" x 12" x 8" 1 No 1183
04254
511 MAT- ELEC-8.1.33 11 KV/ 22 KV Hand gloves 1 No 220
04255
512 MAT- ELEC-8.1.34 100mm CI pipe 1 mtr As per civil SOR
04256
8.2 LEGEND PLATES

513 ELEC-8.2.1 Danger Notice Plates of size ---------------------, shall comply with IS:2551-
1982

MAT- a 250x200mm, 1 No 248


04257
MAT- b 200x150mm, 1 No 220
04258
MAT- c 150x100mm, 1 No 110
04259
514 MAT- ELEC-8.2.2 Bus bar chamber 100mm x 40mm 1 No 55
04260
515 MAT- ELEC-8.2.3 Cable Alley 100mm x 40mm 1 No 55
04261
516 MAT- ELEC-8.2.4 Earth 40mm x 20mm 1 No 55
04262

517 MAT- ELEC-8.2.5 Auto / Manuual 1 No 55


04263
518 MAT- ELEC-8.2.6 Semi ovel type alluminium anodized 1 No 28
04264 legend plates ON / OFF / Forward /
Reverse / Start / Stop / UP / DOWN /
R Phase / Y Phase / B Phase / Trip /
Open / Close / Left / Right / Motor on /
Motor off / Accept / Retract / Reset /
Emergency / Running / Pump off /
Emergency Stop / Emergnecy on /
Slow.

163
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
519 MAT- ELEC-8.2.7 Shock instrution chart in English / 1 No 495
04265 Hindi / Telugu duly framed with front
glass
8.3 COPPER / ALLUMINIUM / G.I.
ITEMS (PER KG)
520 MAT- ELEC-8.3.1 Copper Plate / Strip / SWG wire No.8 / 1 kg 679
04266 10 / 14

521 MAT- ELEC-8.3.2 Copper winding wire 1 kg 782


04267
522 MAT- ELEC-8.3.3 Copper winding wire with PVC 1 kg 805
04268 Insulated of fine quality

523 MAT- ELEC-8.3.4 Alluminum Bus bars / Strips / 1 kg 253


04269 Accessories

524 MAT- ELEC-8.3.5 Alluminum winding wire 1 kg 330


04270
525 MAT- ELEC-8.3.6 G.I. Strip / Plate / Wire 1 kg 72
04271
8.4 SMC TYPE SUPPORTS FOR THE
BUSBARS
526 ELEC-8.4.1 Supply of type supports for the bus
bars-------------
MAT- a 50 x 70 x 14 mm 1 No 33
04272
MAT- b 60 x 70 x 14 mm 1 No 39
04273
MAT- c 70 x 70 x 14 mm 1 No 72
04274
MAT- d 300 x 50 x 10 mm 1 No 22
04275
MAT- e 350 x 52 x 10 mm 1 No 176
04276
MAT- f 420 x 60 x 12 mm 1 No 253
04277
527 MAT- ELEC-8.4.2 DMC Earth Flat Supports 20 x3 mm / 1 No 55
04278 20x 6mm / 25 x 6mm / 25 x 3mm / 32
x 3 mm / 32 x 6mm / 40 x 3 mm / 40 x
6mm
528 MAT- ELEC-8.4.3 Heat shrinkable sleeves for the Bus 1 Mtr 17
04279 bars up to 70 Sqmm

529 MAT- ELEC-8.4.4 Heat shrinkable sleeves for the Bus 1 Mtr 28
04280 bars above 70 Sqmm

530 MAT- ELEC-8.4.5 8 mm LED series bulb (54 Nos.) Set 330

164
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

04281
531 MAT- ELEC-8.4.6 8 mm LED series bulb with Navar Set 2750
04282 Patta (250/300 Nos.) with necessary
control gear
MAT- ELEC-8.4.7 LED RGB pixel series bulbs(50 Nos) Set 605
05588
MAT- ELEC-8.4.8 LED RGB pixel series bulbs with Set 4950
05589 Navvar Patta(150 Nos) with
necessary control gear
MAT- ELEC-8.4.9 Supply of 3W X54 LED RGB PAR 1 No 10450
05590 cans with IP 67 protection
533 MAT- ELEC-8.4.10 Supply and fixing of 6mm thick MS 1 Kg 77
04284 Chekered plate.

534 MAT- ELEC-8.4.11 Supply and fixing of 6mm thick 1 Kg 275


04285 Alluminium Chekered plate

535 MAT- ELEC-8.4.12 Copper old winding Wire scrap for 1 1 Kg 165
04286 Kg

536 MAT- ELEC-8.4.13 Cement 1 Kg 9


04287
537 ELEC-8.4.14 Cost of Sand 1 Cum 660

538 ELEC-8.4.15 Cost of Bricks 1000 Nos 4400

539 MAT- ELEC-8.4.16 Hylam Sheet 1 Sq inch 1


04288

540 ELEC-8.4.17 Supply of Nominal-Bore ---------------


G.I.Pipe
MAT- a 25mm Heavy grade 1 mtr 308
04289
MAT- b 25mm Medium grade 1 mtr 270
04290
MAT- c 40mm Heavy grade 1 mtr 462
04291
MAT- d 40mm Medium grade 1 mtr 385
04292
541 MAT- ELEC-8.4.18 80mm Nominal Bore C.I.Earth Pipe of 1 no 3740
04293 3 Mtrs Length

542 MAT- ELEC-8.4.19 Earth work excacvation including all 1 cum 275
04294 soils for trench, Pole Pit and Earth Pit

543 MAT- ELEC-8.4.20 Drilling of 16 Nos through holes of 1 No 7


04295 12mm dia to G.I pipe

544 MAT- ELEC-8.4.21 G.I Nuts, Bolts and Washers each set 1 set 13

165
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

04296
545 MAT- ELEC-8.4.22 18" dia 2" thick hume pipe ring 1 No 275
04297
546 MAT- ELEC-8.4.23 18" dia 3" hume pipe ring 1 No 330
04298
547 MAT- ELEC-8.4.24 2" thick CC cover for hume pipe ring 1 No 143
04299 with handle.

548 ELEC-8.4.25 Supply of Saddle / Clamps suitable for fixing ------------


------

MAT- a 4 to 10 Sqmm 2 Core Cable 100 Nos 253


04300
MAT- b 4 & 6 Sqmm 4 Core Cable 100 Nos 253
04301
MAT- c 10 & 16 Sqmm 4 Core Cable 100 Nos 330
04302
MAT- d 25 & 35 Sqmm 3.5 Core Cable. 100 Nos 385
04303
MAT- e 50 Sqmm 3.5 Core Cable. 100 Nos 550
04304
MAT- f 70 & 95 Sqmm 3.5 Core Cable 100 Nos 605
04305
MAT- g 120 to 185 Sqmm 3.5 Core Cable 100 Nos 770
04306
MAT- h 240 & 300 Sqmm 3.5 Core Cable 100 Nos 935
04307
MAT- i 400 Sqmm 3.5 Core Cable 100 Nos 1210
04308
549 ELEC-8.4.26 Supply and fixing of PVC synthetic elastomer electrically insulated mat
conforming to IS: 15652-2006 with----------------

MAT- a Class A insulation having 2mm 1 sqmt 4180


04309 thickness upto 3.3KV

MAT- b Class B insulation having 2.5mm 1 sqmt 4290


04310 thickness upto 11KV

MAT- c Class C insulation having 3mm 1 sqmt 4400


04311 thickness upto 33KV

166
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
550 MAT- ELEC-8.4.27 Supply of round bottom G.I sheet 1 no 297
04312 bucket of 9 Ltrs. Capacity as per
IS:2546 made out of 24 gauge GI
sheet with extra handle at bottom duly
painted inside and red out side with
printed with FIRE Mark for
stand and hook and filled with sand
and arranged to existing stand or
hook. ( MR )
551 MAT- ELEC-8.4.28 Providing floor mounting stand for 1 no 1210
04313 keeping 4No of fire bucket 1500mm
length, 900mm height made out of
40x40x6mm angle iron welded with 4
hooks and duly painted with one coat
of red lead and two coats of enamel
paint.
552 ELEC-8.4.29 Supply of GI Louver shutter for
exhaust fan
MAT- a 9 to 12" 1 no 165
04314
MAT- b 15 to 18" 1 no 198
04315
553 MAT- ELEC-8.4.30 EICHER model 11:10 with 100 H. 1 No 682000
04316 P direct injestion 4 stroke engine
with one spare wheel 3800 mm cabin
high deck with jangla (full body) (4
wheeler) for generator
LABOUR RATES

554 ELEC-8.5.1 Skilled Electrician 1 No

555 ELEC-8.5.2 Semi Skilled Electrician / Lineman 1 No

556 ELEC-8.5.3 Helper (Electrical) 1 No

557 ELEC-8.5.4 Skilled Mason 1 No

558 ELEC-8.5.5 Semi Skilled Mason 1 No

559 ELEC-8.5.6 Skilled Welder 1 No

560 ELEC-8.5.7 Skilled Fitter 1 No

561 ELEC-8.5.8 Semi Skilled Fitter / Welder 1 No

562 ELEC-8.5.9 Skilled Carpenter 1 No

563 ELEC-8.5.10 Semi Skilled Carpenter 1 No

564 ELEC-8.5.11 Man Mazdoor 1 No

565 ELEC-8.5.12 DG Set operator/Air Compressor 1 No


Operator
566 ELEC-8.5.13 2nd Class DG Set operator/Air 1 No
Compressor Operator

167
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
567 ELEC-8.5.14 Plumber (Licensed)/Pipe Fitter 1 No

568 ELEC-8.5.15 Painter Class -2 1 No

569 ELEC-8.5.16 Diploma Engineer / Surveyor 1 No

570 ELEC-8.5.17 Graduate Engineer 1 No

571 ELEC-8.5.18 ITI Certificate holder 1 No

572 ELEC-8.5.19 Stenographer / Computer Operator 1 No

NB : The labour rates may be adopted based on the common Civil


SoR for the year 2021-22
9.1 WIRELESS FIRE ALARAM SYSTEM

573 MAT- ELEC-9.1.1 Supply and fixing of wireless smoke 1 No 40250


04336 detection control panel of 28 wireless
zones, 2 Hard wired Zones, Tamper
Alert, Pass code protected, RF
jamming recognition, diagnostic
feature for RF signal strength between
panel and each detector, vent
reporting using PSTN telephone line,
dialing upto 4 telephone numbers,
event reporting as per users choice,
LCD screen display, two way voice
interaction, battery backup stand by
time up to 12 hrs. Including
transportation, all taxes and all labour
charges etc complete.
Makes : As per list of recommended
brands.
574 MAT- ELEC-9.1.2 Supply and fixing of Wireless 1 No 9775
04337 Repeater.The wireless repeater
extends the communication range of
detection by relaying data between
receiver and remote wireless
transmitter including transportation, all
taxes and all labour charges etc
complete.
Makes : As per list of recommended
brands.

168
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
575 MAT- ELEC-9.1.3 Supply and fixing of Wireless Siren 1 No 13225
04338 Strobe external wireless siren - a fully
supervised power code outdoor (IP55)
wireless Siren and strobe light.
Designed for external installation.
Wire - Free connection between
control panel and siren. Convenient
rapid no- mess installation. Separate
fire alarm signals, 98db Piezo siren
and high power strobe light. Weather
resistant, IP55, 2-way communication
for local and remote diagnostics. Plug-
in power supply, NIMH rechargeable
back-up power battery, transmits
status, tamper, low- battery,
supervisory and AC loss messages to
the control panel, Tri- State tamper
switch identifies screw manipulation
removal of cover or playing from the
wall including transportation, all taxes
and all labour charges etc complete.
Makes : As per list of recommended
brands.
576 MAT- ELEC-9.1.4 Supply and fixing of wireless Fully 1 No 6613
04339 Supervised Smoke Detector,
Photoelectric detection technology for
superior detection sensitivity , sound
and transmitted for smoke, tamper
and low battery, works on power code
protocol, easy programming and
enrolling to the control panel, long life
9 volt alkaline or lithium battery
including transportation, all taxes and
all labour charges etc complete.
Makes : As per list of recommended
brands.
9.2 ADDRESSABLE - FIRE ALARM
SYSTEM
577 ELEC-9.2.1 Supply, install, test and commissioning of addressable peer to peer
Networkable analogue addressable type fire alarm control panel with
minimum 1500 Character / 240X64 Pixel / 7inch Touchscreen graphic
LCD display. The panel should be equipped with sufficient numbers of
loop with 20% spare capacity, with each networkable intelligent fire alarm
Control Panel having SLC with capacity of min 250 detectors/ devices in
any combination (Min 120 Detector) with key pad, dual flash-based
microprocessor technology, inbuilt USB Port for upload and down load
the configuration tools, RS232 serial port for direct PC or modem
connection, inbuilt NAC's, min 20 programmable Zonal LEDs and
operates on 240V AC + 10% with 50 Hz with built in charger. The panel
shall have fire, fault relays, option of BMS integration MODBUS/
BACKNET, graphical software for provision of TCP/ IP modules, Remote
Access, Class 'X' wiring with provision of both class 'A' and class 'B'
wiring in the SLC circuit, user friendly with communication facility to
monitor & control the FACPs from a single window. The panel shall be
suitable for minimum of 5000 event record facility, event fetch from FACP
facility and the single panel shall be suitable for min 2000 fire zones and

169
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

200 Panels/ Nodes in one network with all other accessories required to
successfully run the system. The panel shall be completed as perUL and
FM/EN54 & VDS standards (The System cost shall be included of all
necessary cards, modules, Panel enclosure, CPU and associated
accessories to complete the system design)
Makes : As per list of recommended brands as category I.
MAT- a 1 loop 1 No 201250
04340
MAT- b 2 loop 1 No 230000
04341
MAT- c 4 loop 1 No 281750
04342
MAT- d 6 loop 1 No 419750
04343
MAT- e 8 loop 1 No 460000
04344
MAT- f 10 loop 1 No 632500
04345
577 ELEC-9.2.2 Supply, install, test and commissioning of addressable peer to peer
Networkable analogue addressable type fire alarm control panel with
minimum 1500 Character / 240X64 Pixel / 7inch Touchscreen graphic
LCD display. The panel should be equipped with sufficient numbers of
loop with 20% spare capacity, with each networkable intelligent fire alarm
Control Panel having SLC with capacity of min 250 detectors/ devices in
any combination (Min 120 Detector) with key pad, dual flash-based
microprocessor technology, inbuilt USB Port for upload and down load
the configuration tools, RS232 serial port for direct PC or modem
connection, inbuilt NAC's, min 20 programmable Zonal LEDs and
operates on 240V AC + 10% with 50 Hz with built in charger. The panel
shall have fire, fault relays, option of BMS integration MODBUS/
BACKNET, graphical software for provision of TCP/ IP modules, Remote
Access, Class 'X' wiring with provision of both class 'A' and class 'B'
wiring in the SLC circuit, user friendly with communication facility to
monitor & control the FACPs from a single window. The panel shall be
suitable for minimum of 5000 event record facility, event fetch from FACP
facility and the single panel shall be suitable for min 2000 fire zones and
200 Panels/ Nodes in one network with all other accessories required to
successfully run the system. (The System cost shall be included of all
necessary cards, modules, Panel enclosure, CPU and associated
accessories to complete the system design).
Makes : As per list of recommended brands as category II.
MAT- a 1 loop 1 No 180550
04346
MAT- b 2 loop 1 No 202400
04347
MAT- c 4 loop 1 No 234600
04348
MAT- d 6 loop 1 No 339250

170
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

04349
MAT- e 8 loop 1 No 393300
04350
MAT- f 10 loop 1 No 563500
04351
578 MAT- ELEC-9.2.3 Supply, Installation , Testing & 1 No 120750
04352 Commissioning of Network Active
Repeater Panel with 1500 Character /
240X64 Pixel / 7inch Touchscreen.
The LCD shall Display all events /
detectors, devices status of complete
systems in the networked.
Makes : As per list of recommended
brands as category I.
579 MAT- ELEC-9.2.4 Supply, Installation , Testing & 1 No 98325
04353 Commissioning of Network Active
Repeater Panel with 1500 Character /
240X64 Pixel / 7inch Touchscreen.
The LCD shall Display all events /
detectors, devices status of complete
systems in the networked.
Makes : As per list of recommended
brands as category II.
580 MAT- ELEC-9.2.5 Supply, Installation, Testing & 1 No 5290
04354 Commissioning of Analogue
Addressable loop powered Sounder &
Beacon with inbuilt isolator and
having Min 15 distinct sound patterns/
multitone to indicate Exit doors and
direct occupants for safe and fast
evacuation and 100dB output with
minimum 1Hz Frequency flash rate
designed for IP65 requirements and
approved to operate in –10°C to
+55°C temperature, complies with the
essential requirement of the EMC
Directive to be supplied with Junction
Box, Glands and other mounting
accessories for proper installation.
Makes : As per list of recommended
brands as category I.
581 MAT- ELEC-9.2.6 Supply, Installation, Testing & 1 No 4255
04355 Commissioning of Analogue
Addressable loop powered Sounder &
Beacon with inbuilt isolator and
having Min 15 distinct sound patterns/
multitone to indicate Exit doors and
direct occupants for safe and fast
evacuation and 100dB output with
minimum 1Hz Frequency flash rate
designed for IP65 requirements and
approved to operate in –10°C to
+55°C temperature, complies with the

171
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

essential requirement of the EMC


Directive to be supplied with Junction
Box, Glands and other mounting
accessories for proper installation
Makes : As per list of recommended
brands as category II.
582 MAT- ELEC-9.2.7 Supply, Installation, Testing & 1 No 5175
04356 Commissioning of Dust and Vermin
proof (Resettable) addressable
analogue Manual call boxes along
with Isolators inbuilt having front reset
mechanism with 170° viewable LED
and can be viewed from the distance
of 7 M. also have inbuilt isolator
having operating temperature from -
40°C-70°C to initiate audio visual
alarm in case of Human detection of
fire. The manual call point must be
indoor type with IP 44 rating.The call
point must be ressatable type without
breakglass.
Makes : As per list of recommended
brands as category I.
583 MAT- ELEC-9.2.8 Supply, Installation, Testing & 1 No 4600
04357 Commissioning of Dust and Vermin
proof (Resettable) addressable
analogue Manual call boxes along
with Isolators inbuilt having front reset
mechanism with 170° viewable LED
and can be viewed from the distance
of 7 M. also have inbuilt isolator
having operating temperature from -
40°C-70°C to initiate audio visual
alarm in case of Human detection of
fire. The manual call point must be
indoor type with IP 44 rating.The call
point must be ressatable type without
breakglass.
Makes : As per list of recommended
brands as category II.
584 MAT- ELEC-9.2.9 Optical smoke detector with LED with 1 No 4370
04358 standard base having capacity of min
126 address combination. Operating
temperature -40°C to 70°C &Humidity
0-95%. The detector should have
polling 360 degree viewable LED with
5 class approved response modes all
approved with the relevant standards
, drift compensation and transient
rejection.The detector shall have
facility to mount in different
comprehensive environment like
Hostile environment, Precious
storage, Ware house and normal
working environments. The detector
should have self locking mechanism

172
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

and requires special tool to remove


this detectors. The detector should
have hard address inside the base.
The detector must have non volatile
memory to write the installation date &
site codes.The detector should be
mad up of fire retardant material &
should be melt above 100 degree
C.The detectors must be openable for
the cleaning of dust whenever
required. All the other specs should
be as per the specification attached.
Makes : As per list of recommended
brands as category I.
585 MAT- ELEC-9.2.10 Optical smoke detector with LED with 1 No 3853
04359 standard base having capacity of min
126 address combination. Operating
temperature -40°C to 70°C &Humidity
0-95%. The detector should have
polling 360 degree viewable LED with
5 class approved response modes all
approved with the relevant standards
, drift compensation and transient
rejection.The detector shall have
facility to mount in different
comprehensive environment like
Hostile environment, Precious
storage, Ware house and normal
working environments. The detector
should have self locking mechanism
and requires special tool to remove
this detectors. The detector should
have hard address inside the base.
The detector must have non volatile
memory to write the installation date &
site codes.The detector should be
mad up of fire retardant material &
should be melt above 100 degree
C.The detectors must be openable for
the cleaning of dust whenever
required. All the other specs should
be as per the specifications.
Makes : As per list of recommended
brands as category II.
586 MAT- ELEC-9.2.11 Analogue Addressable Heat detector 1 No 4715
04360 and LED with standard base having
capacity of min 126 address
combination. Storage temperature -
40°C to 80°C & Humidity 0-95%.The
detector shall have facility to mount in
different comprehensive environment
like Hostile environment, Precious
storage, Ware house and normal
working environments. The heat
detector must trigger the alarm as per
the A1R/A2R/A2S/CR/CS

173
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

requirement.The detector should have


self locking mechanism and requires
special tool to remove this
detectors.The detector must have non
volatile memory to write the
installation date & site codes.
Makes : As per list of recommended
brands as category I.
587 MAT- ELEC-9.2.12 Analogue Addressable Heat detector 1 No 4140
04361 and LED with standard base having
capacity of min 126 address
combination. Storage temperature -
40°C to 80°C & Humidity 0-95%.The
detector shall have facility to mount in
different comprehensive environment
like Hostile environment, Precious
storage, Ware house and normal
working environments. The heat
detector must trigger the alarm as per
the A1R/A2R/A2S/CR/CS
requirement.The detector should have
self locking mechanism and requires
special tool to remove this
detectors.The detector must have non
volatile memory to write the
installation date & site codes.
Makes : As per list of recommended
brands as category II.
588 MAT- ELEC-9.2.13 Analogue Addressable Multisensor 1 No 4830
04362 (Smoke & Heat) detector with LED
with standard base having capacity of
min 126 address combination.
Operating temperature -40°C to 70°C
&& Humidity 0-95%. The detector
should have polling 360 degree
viewable LED with 5 class approved
response modes all approved with the
relevant standards , drift
compensation and transient rejection.
The detector should trigger heat alarm
as per the A1R class requirement.The
detector shall have facility to mount in
different comprehensive environment
like Hostile environment, Parking
Garage, Precious storage, Ware
house and normal working
environments. The detector should
have self locking mechanism and
requires special tool to remove this
detectors.The detector should have
hard address inside the base.The
detector should be mad up of fire
retardant material & should be melt
above 100 degree C. The detectors
must be openable for the cleaning of
dust whenever required.The detector

174
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

must have 4 non volatile memory to


write the installation date & site codes
Makes : As per list of recommended
brands as category I.

589 MAT- ELEC-9.2.14 Analogue Addressable Multisensor 1 No 4140


04363 (Smoke & Heat) detector with LED
with standard base having capacity of
min 126 address combination.
Operating temperature -40°C to 70°C
&& Humidity 0-95%. The detector
should have polling 360 degree
viewable LED with 5 class approved
response modes all approved with the
relevant standards , drift
compensation and transient rejection.
The detector should trigger heat alarm
as per the A1R class requirement.The
detector shall have facility to mount in
different comprehensive environment
like Hostile environment, Parking
Garage, Precious storage, Ware
house and normal working
environments. The detector should
have self locking mechanism and
requires special tool to remove this
detectors.The detector should have
hard address inside the base.The
detector should be mad up of fire
retardant material & should be melt
above 100 degree C. The detectors
must be openable for the cleaning of
dust whenever required.The detector
must have 4 non volatile memory to
write the installation date & site codes
Makes : As per list of recommended
brands as category II.
590 MAT- ELEC-9.2.15 Supply, install, test and 1 No 4830
04364 commissioning of Analogue
addressable Control (Input/Output)
module with inbuilt relay and isolator
with LED indicator, approved to
operate in –10°C to +55°C
temperature, complies with the
essential requirement of the EMC
Directive to be supplied with Junction
Box and other mounting accessories
for proper installation. In case of
Manufacturer with single Input or
Output module need to supply One
quantity of each for line item.
Makes : As per list of recommended
brands as category I.

175
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
591 MAT- ELEC-9.2.16 Supply, install, test and 1 No 4255
04365 commissioning of Analogue
addressable Control (Input/Output)
module with inbuilt relay and isolator
with LED indicator, approved to
operate in –10°C to +55°C
temperature, complies with the
essential requirement of the EMC
Directive to be supplied with Junction
Box and other mounting accessories
for proper installation. In case of
Manufacturer with single Input or
Output module need to supply One
quantity of each for line item .
Makes : As per list of recommended
brands as category II.
592 MAT- ELEC-9.2.17 Supply, install, test and 1 No 4830
04366 commissioning of Analogue
addressable Control (Input/Output)
module with inbuilt relay and isolator
with LED indicator, approved to
operate in –10°C to +55°C
temperature, complies with the
essential requirement of the EMC
Directive to be supplied with Junction
Box and other mounting accessories
for proper installation. In case of
Manufacturer with single Input or
Output module need to supply One
quantity of each for line item.
Makes : As per list of recommended
brands as category I.
593 MAT- ELEC-9.2.18 Supply, install, test and 1 No 4255
04367 commissioning of Analogue
addressable Control (Input/Output)
module with inbuilt relay and isolator
with LED indicator, approved to
operate in –10°C to +55°C
temperature, complies with the
essential requirement of the EMC
Directive to be supplied with Junction
Box and other mounting accessories
for proper installation. In case of
Manufacturer with single Input or
Output module need to supply One
quantity of each for line item 5 years
of warranty..
Makes : As per list of recommended
brands as category II.
594 MAT- ELEC-9.2.19 Supply, Installation, Testing & 1 No 4370
04368 Commissioning of Loop isolation
module which consists of LED. This
LED shall be mounted with in a round
polycarbonate encloser. Isolator Base
for Isolators.
Makes : As per list of recommended

176
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

brands as category I.

595 MAT- ELEC-9.2.20 Supply, Installation, Testing & 1 No 3450


04369 Commissioning of Loop isolation
module which consists of LED. This
LED shall be mounted with in a round
polycarbonate encloser. Isolator Base
for Isolators.
Makes : As per list of recommended
brands as category II.
9.3 CONVENTIONAL - FIRE ALARM
SYSTEM
596 ELEC-9.3.1 Supply, Installation, testing and commissioning of conventional Micro
processor based Fire Alarm panel with ……., 12V SMF batteries etc.,
complete with all standard accessories.
Makes : As per list of recommended brands.
MAT- a 2 Zone 1 No 15525
04370
MAT- b 4 Zone 1 No 16675
04371
MAT- c 6 Zone 1 No 17250
04372
MAT- d 8 Zone 1 No 17825
04373
MAT- e 10 Zone 1 No 22425
04374
MAT- f 12 Zone 1 No 25875
04375
MAT- g 14 Zone 1 No 29325
04376
597 MAT- ELEC-9.3.2 Supply and installation of Repeater 1 No 13800
04377 panel including the cost of mounting
accessories complete as per
specifications and as required.
Makes : As per list of recommended
brands.
598 MAT- ELEC-9.3.3 Supply and installation of duel tone 1 No 863
04378 electronic hooter of 85dB including the
cost of mounting accessories
complete as per specifications and as
required.
Makes : As per list of recommended
brands.

177
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
599 MAT- ELEC-9.3.4 Supply and installation of dust and 1 No 690
04379 vermin proof manual call point to
initiate audio visual alarm including
the cost of mounting accessories
complete as per specifications and as
required.
Makes : As per list of recommended
brands.
600 MAT- ELEC-9.3.5 Supply and installation of response 1 No 173
04380 indicators for above false ceiling
detectors.
Makes : As per list of recommended
brands.
601 MAT- ELEC-9.3.6 Supply and installation of plug - in 1 No 1840
04381 type multi criterion detectors including
the cost of base plate. 75mm dia M.S.
outlet box for fixing of the detector
base. Mounting accessories etc.,
complete as per specifications as
required.
Makes : As per list of recommended
brands.

602 MAT- ELEC-9.3.7 Supply and installation of plug -in type 1 No 1610
04382 photo electric smoke detectors
including the cost of base plate.
75mm dia MS outlet box for fixing of
the detector base. Mounting
accessories etc complete and as per
specifications and as required.
Makes : As per list of recommended
brands.
603 MAT- ELEC-9.3.8 Supply and installation of plug -in type 1 No 1495
04383 rate of rise cum fixed temperature
heat detectors including the cost of
base plate. 75mm dia MS outlet box
for fixing of the detector base,
mounting accessories etc., complete
as per specifications and as required.
Makes : As per list of recommended
brands.
9.4 POWDER BASED FIRE
EXTINGUISHERS
604 Supply and fixing of ABC stored pressure squeeze grip type fire
extinguishers, 9 kg capacity, IS:15683 : 2006, filled with ABC Mono
Ammonium Phosphate base powder-90 complete with discharge hose
and wall mounting bracket, 2mm Mild Steel, EPDM Rubbers, Pressure
Guage, which work effectively on all class of fires (A, B, C & Electrical
fires) with 5 years warranty Including transportation, all taxes and all
labour charges etc complete.

MAT- ELEC-9.4.1 Makes : As per list of recommended 1 No 9315


04384 brands as category I.

178
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-9.4.2 Makes : As per list of recommended 1 No 5980


04385 brands as category II.

605 Supply and fixing of ISI mark (IS:15683) Mono ammonium phosphate
powder 90 (MAP) 2 Kg Fire extinguisher, stored pressure type, pressure
gauge, gross wt. 3.6 kg, empty wt.1.6 kg, Discharge time minimum 8
sec, controllable discharge mechanism, range min. 2 mts applicable on
classes A,B, C & electrically started fire, A rating -2 A, B rating -21 B,
can construction: Deep drawn and Co2 mig welding, Valve construction:
Forging & Machining, internal coating of can: Epoxy powder coating,
External coating of Can:Epoxy polyster powder coating, sheet metal
thickness:1.60mm, Helium leak detection tested with 5 years warranty
Including transportation, all taxes and all labour charges etc complete.

MAT- ELEC-9.4.3 Makes : As per list of recommended 1 No 4600


04386 brands as category I.

MAT- ELEC-9.4.4 Makes : As per list of recommended 1 No 3910


04387 brands as category II.

606 Supply and fixing of ISI mark (IS:15683) Mono ammonium phosphate
powder 90 (MAP) 4 Kg Fire extinguisher, stored pressure type, pressure
gauge, gross wt. 6.9 kg, empty wt.2.9 kg, Discharge time minimum 13
sec, controllable discharge mechanism, range min. 4 mts applicable on
classes A,B, C & electrically started fire, A rating -3 A, B rating -34 B,
can construction: Deep drawn and Co2 mig welding, Valve construction:
Forging & Machining, internal coating of can: Epoxy powder coating,
External coating of Can:Epoxy polyster powder coating, sheet metal
thickness:1.60mm, Helium leak detection tested with 5 years warranty
Including transportation, all taxes and all labour charges etc complete.

MAT- ELEC-9.4.5 Makes : As per list of recommended 1 No 6555


04388 brands as category I.

MAT- ELEC-9.4.6 Makes : As per list of recommended 1 No 4370


04389 brands as category II.

607 Supply and fixing of ISI mark (IS:15683) Mono ammonium phosphate
powder 90 (MAP) 6 Kg Fire extinguisher, stored pressure type, pressure
gauge, gross wt. 9.4 kg, empty wt.3.4 kg, Discharge time minimum 13
sec, controllable discharge mechanism, range min. 4 mts applicable on
classes A,B, C & electrically started fire, A rating -4 A, B rating -34 B,
can construction: Deep drawn and Co2 mig welding, Valve construction:
Forging & Machining, internal coating of can: Epoxy powder coating,
External coating of Can:Epoxy polyster powder coating, sheet metal
thickness:1.60mm, Helium leak detection tested with 5 years warranty
Including transportation, all taxes and all labour charges etc complete.
MAT- ELEC-9.4.7 Makes : As per list of recommended 1 No 7475
04390 brands as category I.

MAT- ELEC-9.4.8 Makes : As per list of recommended 1 No 5980


04391 brands as category II.

CLEAN AGENT FIRE


EXTINGUISHERS

179
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
608 Supply and fixing of ISI mark (IS:15683) Clean Agent HCFC 123, 2
KGFire exitinguisher , Stored pressure type, pressure guage, gross
weight 3.7Kg , empty weight 1.7 Kg, discharge time minimum 8 secs,
controllable discharge mechanism, range minimum 2 meters, applicable
on class A,B,C and electrically started Fire, A rating- 1A, B rating-21B,
can construction: Deep drawn & CO2 mig welded, Valve construction:
Forging & Machining, Internal coating of Can: Epoxy powder coating,
External coating of can: Epoxy polyster powder coating, sheet metal
thickness: 1.60 mm, Helium leak detection tested, 5 Years warranty

MAT- ELEC-9.4.9 Makes : As per list of recommended 1 No 13340


04392 brands as category I.

MAT- ELEC-9.4.10 Makes : As per list of recommended 1 No 11040


04393 brands as category II.

609 Supply and fixing of ISI mark (IS:15683) Clean Agent HCFC 123, 4 Kg
Fire exitinguisher , Stored pressure type, pressure guage, gross weight
6.9Kg , empty weight 2.9 Kg, discharge time minimum 8 secs,
controllable discharge mechanism, range minimum 2 meters, applicable
on class A,B,C and electrically started Fire, A rating- 1A, B rating-21B,
can construction: Deep drawn & CO2 mig welded, Valve construction:
Forging & Machining, Internal coating of Can: Epoxy powder coating,
External coating of can: Epoxy polyster powder coating, sheet metal
thickness: 1.60 mm, Helium leak detection tested, 5 Years warranty.

MAT- ELEC-9.4.11 Makes : As per list of recommended 1 No 22425


04394 brands as category I.

MAT- ELEC-9.4.12 Makes : As per list of recommended 1 No 20125


04395 brands as category II.

610 Supply and fixing of Co2 type Fire Extinguishers 4.5 Kg capacity
confirming to IS 2878 made from ISI marked steam less cylinder
confirming to IS:7285 & CE certified and fitted with ISI marked controlled
valve confirming to IS:3224, high pressure 1 Mtr discharge hose & horn
complete with initial gas charged with carrying handle with wheels and
wall mounting bracket. Squeeze lever discharge, used un-used indicator,
Aphoxy coated paint (Red) with 93% gloss with 2 years warrantyIncluding
transportation, all taxes and all labour charges etc complete.

MAT- ELEC-9.4.13 Makes : As per list of recommended 1 No 10235


04396 brands as category I.

MAT- ELEC-9.4.14 Makes : As per list of recommended 1 No 7705


04397 brands as category II.

611 MAT- ELEC-9.4.15 Supply and fixing of Escape signage 1 No 1380


04398 boards in Rigid Photo luminecent
based glow in Dark rigid sheet with
high intensity luminous properties with
specificaiton.
Makes : As per list of recommended
brands.

180
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
612 MAT- ELEC-9.4.16 Supply and fixing of Cease fire or its 1 No 15525
04399 equivalent Escape gear Mild Steel box
size 425mmx360mmx140mm Epoxy
powder coated to protect it from
Weathering , smoke hood tested to
Eupropean Standard EN 403 1993-S
known to reduce Carbon Monoxide,
propend(acrloein), hydrogen chloride,
hydrogen Cyanide and Solid and
liquid toxic particles to manageable
level for atleast 15 minutes shall with
stand tempeartures upto 80 degrees
single use only Fire Blanket size 1.2m
x1.8m used to cover any vessel
containing used to Extinguish a
clothing fire wrap blanket around the
victim.
613 MAT- ELEC-9.4.17 Supply and fixing of 4Nos of 9 Ltrs 1 Set 1380
04400 capacity round bottom sand buckets
along with bucket sand, Fire buckets
with round bottom type enamel
painted, white inside & red out side
and letter FIRE inblack out side &
Handle with mounting bracket.
614 MAT- ELEC-9.4.18 Supply and fixing of Fire bucket stand 1 Set 1725
04401 fabricated by M.S. angles to install for
Four numbers of buckets as per local
fire officers standards.
AEROSOL GENERATION SYSTEM
(An alternative to water based sprinkler system)

MAT- ELEC-9.4.19 Supply,Installationand commissioning 1 No 5175


05591 of Auto Detection and Suppression
System using Non Pressurised
Aerosol Generator System with
detection of thermocord to make
the system standalone. It can be
used for all classes of fire, The
product Min. Life shall be 15 years
and no Maintenance. The Discharge
time shall be 8 sec. The Generator
has a net weight of 0.5 kg. Active
Substance of 50gms. The Generator
has a capacity to cover 1 m³.
Makes : As per list of recommended
brands.

MAT- ELEC-9.4.20 Supply,Installationand commissioning 1 No 40250


05592 of Auto Detection and Suppression
System using Non Pressurised
Aerosol Generator System with
detection of thermocord and Inbuilt
Aerosol Sprinkler flexibility of
adjusting it for a temperature of

181
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

57/68/93/141 degree centigrade as


per the site environment to make the
system standalone. It can be used for
all classes of fire, The product Min.
Life shall be 15 years and no
Maintenance.The Discharge time shall
be 18 sec. The Generator has a net
weight of 2 kg. Active Substance of
300 gms. The Generator has a
capacity to cover 6 m³.
Makes : As per list of recommended
brands.
MAT- ELEC-9.4.21 Supply,Installationand commissioning 1 No 51750
05593 of Auto Detection and Suppression
System using Non Pressurised
Aerosol Generator System with
detection of thermocord and Inbuilt
Aerosol Sprinkler flexibility of
adjusting it for a temperature of
57/68/93/141 degree centigrade as
per the site environment to make the
system standalone . It can be used
for all classes of fire, The product
Min. Life shall be 15 years and no
Maintenance. The Discharge time
shall be 22 sec. The Generator has a
net weight of 3 kg. Active Substance
of 0.5 kg. The Generator has a
capacity to cover 10 m³.
Makes : As per list of recommended
brands.
MAT- ELEC-9.4.22 Supply,Installationand commissioning 1 No 74750
05594 of Auto Detection and Suppression
System using Non Pressurised
Aerosol Generator System with
detection of thermocord and Inbuilt
Aerosol Sprinkler flexibility of
adjusting it for a temperature of
57/68/93/141 degree centigrade as
per the site environment to make the
system standalone to make the
system standalone. It can be used for
all classes of fire, The product Min.
Life shall be 15 years and no
Maintenance. The Discharge time
shall be 45 sec. The Generator has a
net weight of 4.6 kg. Active Substance
of 1 kg. The Generator has a capacity
to cover 20 m³.
Makes : As per list of recommended
brands.

182
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-9.4.23 Supply,Installationand commissioning 1 No 94300


05595 of Auto Detection and Suppression
System using Non Pressurised
Aerosol Generator System with
detection of thermocord and Inbuilt
Aerosol Sprinkler flexibility of
adjusting it for a temperature of
57/68/93/141 degree centigrade as
per the site environment to make the
system standalone to make the
system standalone. It can be used for
all classes of fire. The product Min.
Life shall be 15 years and no
Maintenance. The Discharge time
shall be 56 sec.The Generator has a
net weight of 5.6 kg. Active Substance
of 2 kg. The Generator has a capacity
to cover 40 m³.
Makes : As per list of recommended
brands.
MAT- ELEC-9.4.24 Supply,Installationand commissioning 1 No 106950
05596 of Auto Detection and Aerosol
Suppression System using Non
Pressurised Aerosol Generator
System with detection of
thermocord and Inbuilt Aerosol
Sprinkler flexibility of adjusting it
for a temperature of 57/68/93/141
degree centigrade as per the site
environment to make the system
standalone. It can be used for all
classes of fire, The product Min. Life
shall be 15 years and no
Maintenance. The Discharge time
should be 80 sec. The Generator has
a net weight of 8 kg. Active Substance
of 4 kg. The Generator has a capacity
to cover 80 m³.
Makes : As per list of recommended
brands.
MAT- ELEC-9.4.25 Supply,Installationand commissioning 1 No 80500
05597 of Aerosol Fire suppression control
Panel is basically a 10 Zone
conventional panel with LED
indications for sensors is open or fire.
When the fire is detected by Sprinkler,
Aerosol gets activated. 10 Aerosol
Sprinkler input and 10 Aerosol
Generator outputs provided. The
Panel consists of 10 individual manual
operation switch and one master
switch to activate 10 Aerosol
Generator outputs simultaniously

183
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-9.4.26 Supply,Installationand commissioning 1 No 22425


05598 of Aerosol control Switch is a
Controller for Activation of Each
Aerosol Generator
Makes : As per list of recommended
brands.
MAT- ELEC-9.4.27 Providing 'Fire Retardant Paint 1 hr 1 No 2185
05599 Fire Resistance can be used to 'flame
retard only 100 % cotton fabric, is
normally used 'to treat coarse fabric
e.g. tents etc. and gives coverage of
'approx. 120 to 130 sq.ft. to a fabric of
275-325 gsm. 'Can be applied 'Meant
only for 100% cotton and coarse
fabric like canvas '/ tents, natural
wood etc.
Makes : As per list of recommended
brands.
MAT- ELEC-9.4.28 Providing 'Flame retard any kind of 1 No 2990
05600 fabric, be it 100% polyester or '100%
cotton. It is normally used to flame
'retard upholstery, curtains, carpets
etc., gives a coverage 'of approx. 120
to 130 sq.ft. to a fabric of 275-325
gsm.
MAT- ELEC-9.4.29 Providing 'Fire Retardant coat towards 1 No 4830
05601 passive protection to sustain 'up to
1000 Deg.C. for 1 hour. This product
can be used for 'all the materials such
as cable, steel, wood, cloth &
'concrete surface etc.

9.5 FIRE HYDRANT AND SPRINKLER


SYSTEM
ELECTRIC DRIVEN MAIN FIRE PUMPS(SPLIT
CASE)
615 MAT- ELEC-9.5.1 Supplying, installation, testing and 1 Set 368000
04402 commissioning of electric driven main
fire pump suitable for automatic
operation and consisting of following
complete in all respect as required
a) Horizontal type, multistage, centrifugal, split casing pump of cast iron
body & bronze impeller with stainless steel shaft, mechanical seal to
ensure a minimum pressure of 3.5 Kg / sq.cm. at highest and farthest
outlet at specified flow of 1620 lpm at 56 Mtr. head conforming to IS
1520
b) Suitable HP SQ cage induction motor, TEFC, synchronous speed
1500 RPM, suitable for operation on 415Volts, 3 phase 50 Hz. AC with IP
55 protection for enclosure, horizontal foot mounted type with Class-'F'
insulation, conforming to IS-325

184
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
616 MAT- ELEC-9.5.2 Supplying , installation , testing and 1 Set 414000
04403 commissioning of electric driven main
fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required
a) Horizontal type, multistage, centrifugal, split casing pump of cast iron
body & bronze impeller with stainless steel shaft, mechanical seal to
ensure a minimum pressure of 3.5 Kg / sq.cm. at highest and farthest
outlet at specified flow of 2280 lpm at 70 Mtr. head conforming to IS
1520
b) Suitable HP SQ cage induction motor, TEFC, synchronous speed
1500 RPM, suitable for operation on 415Volts, 3 phase 50 Hz. AC with IP
55 protection for enclosure, horizontal foot mounted type with Class-'F'
insulation, conforming to IS-325

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
617 MAT- ELEC-9.5.3 Supplying Installation, testing and Commissioning of 644000
04404 electric driven main fire pump suitable for automatic
operation and consisting of following Complete in all
respect as required.

a)Horizontal type, multistage, centrifugal, split casing pump of cast iron


body and bronze impeller with stainless steel shaft, mechanical seal to
ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest
outlet at specified flow of 2280 LPM and 120 Metres head conforming
to IS 1520.
b)Suitable HP SQ cage induction motor, TEFC, synchronous speed 1500
RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55
protection for enclosure, horizontal foot mounted type with Class-'F'
insulation, conforming to IS-325

c)M.S. fabricated Common base plate, coupling, coupling guard,


foundation bolts etc. as required.
d)Suitable CC foundation of 1:2:4 ratio ( 1 Cement: 2 coarse sand : 4
graded stone aggregate 40 mm nominal size ) duly plastered and with
anti vibration pads.
Makes : As per list of recommended brands.
618 MAT- ELEC-9.5.4 Supplying , installation , testing and 1 Set 477250
04405 commissioning of electric driven main
fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required.

185
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

a) Horizontal type, multistage, centrifugal, split casing pump of cast iron


body & bronze impeller with stainless steel shaft, mechanical seal to
ensure a minimum pressure of 3.5 Kg / sq.cm. at highest and farthest
outlet at specified flow of 2850 lpm at 70 Mtr. head conforming to IS
1520
b) Suitable HP SQ cage induction motor, TEFC, synchronous speed
1500 RPM, suitable for operation on 415Volts, 3 phase 50 Hz. AC with IP
55 protection for enclosure, horizontal foot mounted type with Class-'F'
insulation, conforming to IS-325

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.

MAT- ELEC-9.5.5 Supplying Installation, testing and 1 Set 667000


04406 Commissioning of electric driven main
fire pump suitable for automatic
operation and consisting of following
Complete in all respect as required.
a)Horizontal type, multistage, centrifugal, split casing pump of cast iron
body and bronze impeller with stainless steel shaft, mechanical seal to
ensure a minimum pressure of 3.5 kg/sq.cm. at highest and farthest
outlet at specified flow of 2850 LPM and 120 Metres head conforming to
IS 1520.
b)Suitable HP SQ cage induction motor, TEFC, synchronous speed 1470
RPM, suitable for operation on 415 volts, 3 phase 50 Hz. AC with IP 55
protection for enclosure, horizontal foot mounted type with Class-'F'
insulation, conforming to IS-325

c)M.S. fabricated Common base plate, coupling, coupling guard,


foundation bolts etc. as required.
d)Suitable CC foundation of 1:2:4 ratio ( 1 Cement: 2 coarse sand : 4
graded stone aggregate 40 mm nominal size ) duly plastered and with
anti vibration pads
Makes : As per list of recommended brands.
DIESEL ENGINE DRIVEN FIRE
PUMPS
619 MAT- ELEC-9.5.6 Supplying , installation, Testing and 1 Set 478400
04407 commissioning of diesel engine driven
main fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required

a) Horizontal type, multistage, centrifugal pump of cast iron body &


bronze impeller with stainless steel shaft, mechanical seal to ensure a
minimum pressure of 3.5 Kg / sq.cm. at highest and farthest outlet at
specified flow of 1620 lpm at 56 Mtr head conforming to IS 1520

186
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant BS & IS standard complete with auto starting
mechanism, 12 Volts / 24 Volts electric starting equipment, Diesel Tank,
exhaust pipe extended upto 1 m. outside pump house duly insulated with
50mm thick glass wool with 1.0mm thick alluminium sheet cladding,
residential silencer, instruments and protection as per specification, stop
solenoid for auto stop in the event of fault with audio indications, painted
with post office red colour etc as required.
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
620 MAT- ELEC-9.5.7 Supplying , installation, Testing and 1 Set 690000
04408 commissioning of diesel engine driven
main fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required

a) Horizontal type, multistage, centrifugal pump of cast iron body &


bronze impeller with stainless steel shaft, mechanical seal to ensure a
minimum pressure of 3.5 Kg / sq.cm. at highest and farthest outlet at
specified flow of 2280 lpm at 70 Mtr head conforming to IS 1520

b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant BS & IS standard complete with auto starting
mechanism, 12 Volts / 24 Volts electric starting equipment, Diesel Tank,
exhaust pipe extended upto 1 m. outside pump house duly insulated with
50mm thick glass wool with 1.0mm thick alluminium sheet cladding,
residential silencer, instruments and protection as per specification, stop
solenoid for auto stop in the event of fault with audio indications, painted
with post office red colour etc as required.
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
621 MAT- ELEC-9.5.8 Supplying , installation, Testing and commissioning of 833750
04409 diesel engine driven main fire pump suitable for
automatic operation and consisting of following :
complete in all respect as required

a) Horizontal type, multistage, centrifugal pump of cast iron body &


bronze impeller with stainless steel shaft, mechanical seal to ensure a
minimum pressure of 3.5 Kg / sq.cm. at highest and farthest outlet at
specified flow of 2280 lpm at 120 Mtr head conforming to IS 1520

187
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant BS & IS standard complete with auto starting
mechanism, 12 Volts / 24 Volts electric starting equipment, Diesel Tank,
exhaust pipe extended upto 1 m. outside pump house duly insulated with
50mm thick glass wool with 1.0mm thick alluminium sheet cladding,
residential silencer, instruments and protection as per specification, stop
solenoid for auto stop in the event of fault with audio indications, painted
with post office red colour etc as required.
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
622 MAT- ELEC-9.5.9 Supplying , installation, Testing and 1 Set 782000
04410 commissioning of diesel engine driven
main fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required
a) Horizontal type, multistage, centrifugal pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical seal to ensure a
minimum pressure of 3.5 Kg / sq.cm. at highest and farthest outlet at
specified flow of 2850 lpm at 70 Mtr head conforming to IS 1520

b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant BS & IS standard complete with auto starting
mechanism, 12 Volts / 24 Volts electric starting equipment, Diesel Tank,
exhaust pipe extended upto 1 m. outside pump house duly insulated with
50mm thick glass wool with 1.0mm thick alluminium sheet cladding,
residential silencer, instruments and protection as per specification, stop
solenoid for auto stop in the event of fault with audio indications, painted
with post office red colour etc as required.
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
623 MAT- ELEC-9.5.10 Supplying , installation, Testing and 1 Set 891250
04411 commissioning of diesel engine driven
main fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required
a) Horizontal type, multistage, centrifugal pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical seal to ensure a
minimum pressure of 3.5 Kg / sq.cm. at highest and farthest outlet at
specified flow of 2850 lpm at 120 Mtr head conforming to IS 1520

b) Suitable HP, 1500 RPM water cooled with radiator, diesel engine
conforming to relevant BS & IS standard complete with auto starting
mechanism, 12 Volts / 24 Volts electric starting equipment, Diesel Tank,
exhaust pipe extended upto 1 m. outside pump house duly insulated with
50mm thick glass wool with 1.0mm thick alluminium sheet cladding,
residential silencer, instruments and protection as per specification, stop
solenoid for auto stop in the event of fault with audio indications, painted

188
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

with post office red colour etc as required.

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
ELECTRIC DRIVEN MAIN FIRE PUMPS(END
SUCTION)

624 MAT- ELEC-9.5.11 Supplying , installation , testing and 1 Set 276000


04412 commissioning of electric driven main
fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required

a) End suction back pull out centrifugal pump, Std fitted with BRONZE
IMPELLER & gland packing ,capacity 171 Cum/hr (2850 LPM) at total
head 70 M at operating speed 2900 rpm. Pump duty as per TAC

b) 55 KW / 75 HP, 3000 srpm, TEFC (IP55) horizontal foot mounted,


squirrel cage induction motor, suitable for 415 volts +/- 10%, 3 Ph, 50 Hz
+/-5%, a.c.supply. Class ‘F’ insulated and suitable for ambient
temperature up to 50 deg C. Motor in frame SC 250 M frame for driving
above pump.
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
625 MAT- ELEC 9.5.12 Supplying , installation , testing and 1 Set 225400
04413 commissioning of electric driven main
fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required

a) End suction back pull out centrifugal pump, Std fitted with BRONZE
IMPELLER & gland packing ,capacity 137 Cum/hr (2280 LPM) at total
head 70 mwc at operating speed 2900 rpm. Pump duty as per TAC

b) 45 KW / 60 HP, 3000 srpm, TEFC (IP55) Horizontal foot mounted,


squirrel cage induction motor, suitable for 415 volts +/- 10%, 3 Ph, 50 Hz
+/-5%, a.c.supply. Class ‘F’ insulated and suitable for ambient
temperature up to 50 deg C. Motor in frame SC 225 M frame

189
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
626 MAT- ELEC 9.5.13 Supplying, installation, Testing and commissioning of 165600
04414 Electric engine driven main fire pump suitable for
automatic operation and consisting of following :
complete in all respect as required

a) End suction back pull out centrifugal pump, Std fitted with BRONZE
IMPELLER & gland packing ,capacity 97 Cum/hr (1620 LPM) at total
head 56 mwc at operating speed 2900 rpm. Pump duty as per TAC

b) 30 KW / 40 HP, 3000 srpm, TEFC (IP55) horizontal foot mounted,


squirrel cage induction motor, suitable for 415 volts +/- 10%, 3 Ph, 50 Hz
+/-5%, a.c.supply. Class ‘F’ insulated and suitable for ambient
temperature up to 50 deg C. Motor in frame SC 250 M frame for driving
above pump.
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
DIESEL ENGINE DRIVEN MAIN FIRE PUMPS(END SUCTION)

627 MAT- ELEC-9.5.14 Supplying , installation, Testing and 1 Set 573850


04415 commissioning of diesel engine driven
main fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required
a) End suction back pull out pump, Std fitted with BRONZE Impeller &
gland packing, capable of delivering 171 Cum/hr(2850 LPM) at a total
head of 70 M when operated at 1800 rpm and pump duty as per TAC

b) Liquid cooled, 85 BHP at 1800 rpm, diesel engine (Radiator cooled) 12


Volts starting system with standard accessories

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
628 MAT- ELEC-9.5.15 Supplying, installation, Testing and 1 Set 457700
04416 commissioning of diesel engine driven
main fire pump suitable for automatic
operation and consisting of following :
complete in all respect as required

190
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

a) End suction back pull out pump, Std fitted with BRONZE Impeller &
gland packing, capable of delivering 137 Cum/hr(2280 LPM) at a total
head of 70 M when operated at 2150 rpm and pump duty as per TAC
b) Liquid cooled, 68 BHP at 1800 rpm, Diesel engine (Radiator cooled)
12 Volts starting system with standard accessories

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
629 MAT- ELEC-9.5.16 Supplying , installation, Testing and 1 Set 400200
04417 commissioning of Diesel engine
driven main fire pump suitable for
automatic operation and consisting of
following : complete in all respect as
required
a) End suction back pull out pump, Std fitted with BRONZE Impeller &
gland packing, capable of delivering 97 Cum/hr(1620 LPM) at a total
head of 56 M when operated at 2150 rpm and pump duty as per TAC

b) Liquid cooled, 50 BHP at 1800 rpm, Diesel engine (Radiator cooled)


12 Volts starting system with standard accessories

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.

JOCKEY PUMPS

630 MAT- ELEC-9.5.17 Supplying , installation , testing and 1 Set 56350


04418 commissioning of electric driven
pressurisation / Jockey pump suitable
for automatic operation and consisting
of following : complete in all respect
as required
a) Horizontal type, multistage, centrifugal pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical seal and flow of
180 lpm at 56 Mtr head conforming to IS 1520
b) Suitable HP SQ cage induction motor TEFC type suitable for operation
on 415Volts, 3 phase 50 Hz. AC with IP 55 class of protection for
enclosure, horizontal foot mounted type with Class-'F' insulation,
conforming to IS-325
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.

191
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

d) Suitable cement concrete foundation duly plastered with anti vibration


pads.
Makes : As per list of recommended brands.
631 MAT- ELEC-9.5.18 Supplying , installation , testing and 1 Set 82800
04419 commissioning of electric driven
pressurisation / Jockey pump suitable
for automatic operation and consisting
of following : complete in all respect
as required
a) Horizontal type, multistage, centrifugal pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical seal and flow of
180 lpm at 70 Mtr head conforming to IS 1520

b) Suitable HP SQ cage induction motor TEFC type suitable for operation


on 415Volts, 3 phase 50 Hz. AC with IP 55 class of protection for
enclosure, horizontal foot mounted type with Class-'F' insulation,
conforming to IS-325
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
632 MAT- ELEC-9.5.19 Supplying , installation , testing and 1set 126500
04420 commissioning of electric driven
pressurisation / Jockey pump suitable
for automatic operation and consisting
of following : complete in all respect
as required
a) Horizontal type, multistage, centrifugal pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical seal and flow of
180 lpm at 120 Mtr head conforming to IS 1520

b) Suitable HP SQ cage induction motor TEFC type suitable for operation


on 415Volts, 3 phase 50 Hz. AC with IP 55 class of protection for
enclosure, horizontal foot mounted type with Class-'F' insulation,
conforming to IS-325
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
BOOSTER PUMPS

632 MAT- ELEC-9.5.20 Supplying , installation , testing and 1 Set 64400


04421 commissioning of electric driven
Terrace / Booster pump suitable for
automatic operation and consisting of
following : complete in all respect as
required.

192
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

a) Horizontal type, multistage, centrifugal pump of cast iron body &


bronze impeller with stainless steel shaft, mechanical seal and flow of
900 lpm at 45 Mtr head conforming to IS 1520
b) Suitable HP SQ cage induction motor TEFC type suitable for operation
on 415Volts, 3 phase 50 Hz. AC with IP 55 class of protection for
enclosure, horizontal foot mounted type with Class-'F' insulation,
conforming to IS-325
c) M.S. Fabricated common base plate, coupling, coupling guard,
foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
633 MAT- ELEC-9.5.21 Supplying , installation , testing and 1 Set 50025
04422 commissioning of electric driven
Terrace / Mono Bloc Booster pump
suitable for automatic operation and
consisting of following : complete in all
respect as required.

a) Horizontal type, centrifugal End Suction pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical seal and flow of
900 lpm at 45 Mtr head conforming to IS 1520
b) Three Phase High Speed Centrifugal Pump. Pump with CI Impeller
and Gland Packing with 9.3 KW / 12.5HP, 2 pole, TEFC, 415 V, 3ph
motor

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.
634 MAT- ELEC-9.5.22 Supplying , installation , testing and 1 Set 47725
04423 commissioning of electric driven
Terrace / Mono Bloc Booster pump
suitable for automatic operation and
consisting of following : complete in all
respect as required.
a) Horizontal type, centrifugal End Suction pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical seal and flow of
750 lpm at 35 Mtr head conforming to IS 1520

b) Three Phase High Speed Centrifugal Pump. Pump with CI Impeller


and Gland Packing with 7.5 KW / 10 HP, 2 pole, TEFC, 415 V, 3ph motor

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.

193
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
635 MAT- ELEC-9.5.23 Supplying , installation , testing and 1 Set 43930
04424 commissioning of electric driven
Terrace / Mono Bloc Booster pump
suitable for automatic operation and
consisting of following : complete in all
respect as required.
a) Horizontal type, centrifugal End Suction pump of cast iron body &
bronze impeller with stainless steel shaft, mechanical seal and flow of
450 lpm at 35 Mtr head conforming to IS 1520
b) Three Phase High Speed Centrifugal Pump. Pump with CI Impeller
and Gland Packing with 5 KW / 7.5 HP, 2 pole, TEFC, 415 V, 3ph motor

c) M.S. Fabricated common base plate, coupling, coupling guard,


foundation bolts etc as required.
d) Suitable cement concrete foundation duly plastered with anti vibration
pads.
Makes : As per list of recommended brands.

CONTROL PANELS

MAT- ELEC-9.5.24 Fabrication, supply,Transportation, 1 No 247250


05602 Insallation testing & commissioning of
Electrical control panel of cubical
construction, floor mounted type,
fabricated out of 2mm thick CRCA
sheet, compartmentalised with hinged
lockable doors, dust and vermin proof,
powder coated of approved shade
after 7 tank treatment process, cable
alley, interconnection with suitable
size copper conductor cable/solid
copper strip, having switchgears and
accessories, mountings and internal
wiring, earth terminals, numbering etc.
complete in all respect, suitable for
main fire pump, pressurisation pump
& diesel pump set complete with
following in coming and Outgoings,
suitable for operation on 415V, 3
phase, 50Hz Ac Supply.
Makes : As per list of recommended
brands.
INCOMING :

250A, 50kA 4 Pole MCCB, Ics=100%


Icu rating
Digital Voltmeter 0-500V with selector
switch
Digital Ammeter (0-250 A) with selector swtich & CTs
etc.
LED type RYB phase indicating lamps, ON, OFF, trip indicating lamps

194
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Set of Copper Bus Bar 300A

OUTGOING :

( Note : All outgoing feeders for pumps should have digital Ammeter with
selector switches, and LED type ON, OFF, trip indicating lamps)

MAIN FIRE PUMP

125 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta
starter suitable for 60 HP pump with overload protection, current sensing
type single phase preventor complete with all acceessories and internal
wiring required for automatic operation selector switch for local/remote,
auto/manual/OFF operation.
JOCKEY PUMP

63 A, 50kA TPN MCCB, Ics=100% Icu, with suitable protection, current


sensing type single phase preventor complete with all acceessories and
internal wiring required for automatic operation, selector switch for
ocal/remote, auto/manual/OFF operation.

DIESEL ENGINE CONTROL

Control for diesel engine comprising - Automatic/Manual selctor switch &


3 attempts starting device, timers and relays as required, push buttons,
start/stop in manual mode Indicating lamp for high/ Low Lub. Oil
pressure, High Water Temp and Engine on indication Water Temp and
Engine on indication. Battery charger suitbale for 12V/24 V DC with boost
and trickle selector switch, 0-30 V DC volt meter, and 0- 20 A DC
Ammeter All standard relays and accessories for automatic operation of
diesel engine System Controller.
MAT- ELEC-9.5.25 Designing, Supply, Transportation, 1 No 290950
05603 Installation, Testing and
commissioning of system controller to
control operation of main electric fire
pump, diesel pump, Pressurization
pump, Terrace pump in sequence as
per specification consisting of relays,
timers. Sensors, annunciation window
for fault indication, complete as per
specification
Makes : As per list of recommended
brands.
INCOMING :

400A, 50kA 4 Pole MCCB, Ics=100%


Icu rating
Digital Voltmeter 0-500V with selector
switch
Ammeter (0-400 A) with selector
swtich & CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip

indicating lamps

195
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Set of Copper Bus Bar 500A

OUTGOING :

( Note : All outgoing feeders for


pumps should have
digital Ammeter with selector switches, and LED type

ON, OFF, trip indicating lamps)

MAIN FIRE PUMP

200 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta
starter suitable for 75 hp pump with overload protection, current sensing
type single phase preventor complete with all acceessories and internal
wiring required for automatic operation, selector switch for local/remote,
auto/manual/OFF operation.
JOCKEY PUMP

100 A, 50kA TPN MCCB, Ics=100% Icu, with suitable HP fully automatic
Star/Delta starter with overload protection, current sensing type single
phase preventor complete with all acceessories and internal wiring
required for automatic operation, selector switch for local/remote,
auto/manual/OFF operation.
DIESEL ENGINE CONTROL

Control for diesel engine comprising - Automatic/Manual selctor switch &


3 attempt starting device, timers and relays as required, push buttons,
start/stop in manual mode Indicating lamp for high/ Low Lub. Oil
pressure, High Water Temp and Engine on indication Battery charger
suitbale for 12V/24 V DC with boost and trickle selector switch, 0-30 V
DC volt meter, and 0-20 A DC Ammeter All standard relays and
accessories for automatic operation of diesel engine System Controller
MAT- ELEC-9.5.26 Designing, Supply, Transportation, 1 No 322000
05604 Installation, Testing and
commissioning of system controller to
control operation of main electric fire
pump, diesel pump, Pressurization
pump, Terrace pump in sequence as
per specification consisting of relays,
timers. Sensors, annunciation window
for fault indication, complete as per
specifications.
Makes : As per list of recommended
brands.
INCOMING :

630A, 50kA 4 Pole MCCB, Ics=100%


Icu rating
Digital Voltmeter 0-500V with selector
switch
Ammeter (0-630 A) with selector
swtich & CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip

196
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
indicating lamps

Set of Copper Bus Bar 800Amps

OUT GOING :

( Note : All outgoing feeders for pumps


should have
digital Ammeter with selector switches, and LED type

ON, OFF, trip indicating lamps)

MAIN FIRE PUMP

250 A, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter
suitable for 100 hp pump with overload protection, current sensing type single
phase preventor complete with all acceessories and internal wiring required for
automatic operation, selector switch for local/remote, auto/manual/OFF operation.

JOCKEY PUMP

125 A, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic
Star/Delta starter with over load protection, current sensing type single phase
preventor complete with all acceessories and internal wiring required for
automatic operation, selector switch for local/remote, auto/manual/OFF operation.

DIESEL ENGINE CONTROL

Control for diesel engine comprising - Automatic/Manual selctor switch & 3


attempts starting device, timers and relays as required, push buttons, start/stop in
manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp
and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and
trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All
standard relays and accessories for automatic operation of diesel engine System
Controller.

MAT- ELEC-9.5.27 Designing, Supply, Transportation, 1 No 377200


Installation, Testing and commissioning of
05605
system controller to control operation of
main electric fire pump, diesel pump,
Pressurization pump, Terrace pump in
sequence as per specification consisting
of relays, timers. Sensors, annunciation
window for fault indication, complete as
per specification
Makes : As per list of recommended
brands.
INCOMING :

400A, 50kA 4 Pole MCCB, Ics=100% Icu


Rating
Digital Voltmeter 0-500V with selector
switch
Ammeter (0-400 A) with selector swtich &
CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip

indicating lamps

Set of Copper Bus Bar 500Amps

197
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
OUT GOING :

( Note : All outgoing feeders for pumps


should have
digital Ammeter with selector switches, and LED type

ON, OFF, trip indicating lamps)

MAIN FIRE PUMPS

125 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter
suitable for 60 hp pump with overload protection, current sensing type single
phase preventor complete with all acceessories and internal wiring required for
automatic operation, selector switch for local/remote, auto/manual/OFF operation.
- 2 sets
JOCKEY PUMP

63 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic
Star/Delta starter with overload protection, current sensing type single phase
preventor complete with all acceessories and internal wiring required for
automatic operation, selector switch for local/remote, auto/manual/OFF operation.
- 2 sets
DIESEL ENGINE CONTROL

Control for diesel engine comprising - Automatic/Manual selctor switch & 3


attempts starting device, timers and relays as required, push buttons, start/stop in
manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp
and Engine on indi Battery charger suitbale for 12V/24 V DC with boost and
trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All
standard relays and accessories for automatic operation of diesel engine System
Controller

MAT- ELEC-9.5.28 Designing, Supply, Transportation, 1 No 450800


Installation, Testing and commissioning of
05606
system controller to control operation of
main electric fire pump, diesel pump,
Pressurization pump, Terrace pump in
sequence as per specification consisting
of relays, timers. Sensors, annunciation
window for fault indication, complete as
per specification
Makes : As per list of recommended
brands.

INCOMING :

630A, 50kA 4 Pole MCCB, Ics=100% Icu


Rating
Digital Voltmeter 0-500V with selector
switch
Ammeter (0-630 A) with selector swtich &
CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip

indicating lamps

Set of Copper Bus Bar 800Amps

OUT GOING :

198
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
(Note : All outgoing feeders for pumps
should have
digital Ammeter with selector switches, and LED type

ON, OFF, trip indicating lamps)

MAIN FIRE PUMP

200 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter
suitable for 75 hp pump with overload protection, current sensing type single
phase preventor complete with all acceessories and internal wiring required for
automatic operation, selector switch for local/remote, auto/manual/OFF operation.
- 2 sets
JOCKEY PUMP

100 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic
Star/Delta starter with overload protection, current sensing type single phase
preventor complete with all acceessories and internal wiring required for
automatic operation, selector switch for local/remote, auto/manual/OFF operation.
- 2 sets
DIESEL ENGINE CONTROL

Control for diesel engine comprising - Automatic/Manual selctor switch & 3


attempts starting device, timers and relays as required, push buttons, start/stop in
manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp
and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and
trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All
standard relays and accessories for automatic operation of diesel engine System
Controller.

MAT- ELEC-9.5.29 Designing, Supply, Transportation, 1 No 575000


Installation, Testing and commissioning of
05607
system controller to control operation of
main electric fire pump, diesel pump,
Pressurization pump, Terrace pump in
sequence as per specification consisting
of relays, timers. Sensors, annunciation
window for fault indication, complete as
per specification
Makes : As per list of recommended
brands.
INCOMING :

800A, 50kA 4 Pole MCCB, Ics=100% Icu


Rating
Digital Voltmeter 0-500V with selector
switch
Ammeter (0-800 A) with selector swtich &
CTs etc.
LED type RYB phase indicating lamps, ON, OFF, trip

indicating lamps

Set of Copper Bus Bar 1000Amps

OUT GOING :

( Note : All outgoing feeders for pumps


should have

199
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
digital Ammeter with selector switches, and LED type

ON, OFF, trip indicating lamps)

Main Fire Pump

250 Amp, 50kA TPN MCCB, Ics=100% Icu, with fully automatic Star/Delta starter
suitable for 100 hp pump with overload protection, current sensing type single
phase preventor complete with all acceessories and internal wiring required for
automatic operation, selector switch for local/remote, auto/manual/OFF operation.
- 2 sets
JOCKEY PUMP

125 Amp, 50kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic
Star/Delta starter with overload protection, current sensing type single phase
preventor complete with all acceessories and internal wiring required for
automatic operation, selector switch for local/remote, auto/manual/OFF operation.
- 2 sets
DIESEL ENGINE CONTROL

Control for diesel engine comprising - Automatic/Manual selctor switch & 3


attempts starting device, timers and relays as required, push buttons, start/stop in
manual mode Indicating lamp for high/ Low Lub. Oil pressure, High Water Temp
and Engine on indication Battery charger suitbale for 12V/24 V DC with boost and
trickle selector switch, 0-30 V DC volt meter, and 0-20 A DC Ammeter All
standard relays and accessories for automatic operation of diesel engine System
Controller
MS PIPES

636 ELEC-9.5.30 Providing , laying, testing & Commissioning of following classes MS pipes
conforming to IS 3589 and 1239 including fittings like elbows, tees,
flanges, tapers, nuts, bolts, gaskets etc., complete.
Makes : As per list of recommended brands.
C-CLASS MS PIPES

MAT- a 250 mm dia 1 Mtr 4080


04425
MAT- b 200 mm dia 1 Mtr 3540
04426
MAT- c 150 mm dia 1 Mtr 2700
04427
MAT- d 100 mm dia 1 Mtr 1680
04428
MAT- e 80 mm dia 1 Mtr 1116
04429
MAT- f 65 mm dia 1 Mtr 840
04430
MAT- g 50 mm dia 1 Mtr 672
04431
MAT- h 40 mm dia 1 Mtr 570
04432

200
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- i 32 mm dia 1 Mtr 450


04433
MAT- j 25 mm dia 1 Mtr 336
04434
B- CLASS MS PIPES

MAT- a 250 mm dia 1 Mtr 3600


04435
MAT- b 200 mm dia 1 Mtr 3120
04436
MAT- c 150 mm dia 1 Mtr 2160
04437
MAT- d 100 mm dia 1 Mtr 1440
04438
MAT- e 80 mm dia 1 Mtr 1020
04439
MAT- f 65 mm dia 1 Mtr 756
04440
MAT- g 50 mm dia 1 Mtr 588
04441
MAT- h 40 mm dia 1 Mtr 444
04442
MAT- i 32 mm dia 1 Mtr 360
04443
MAT- j 25 mm dia 1 Mtr 300
04444
637 ELEC-9.5.31 Supplying and fixing single headed Internal / External hydrant valve with
instantaneous Gun metal/Stainless steel couplings of 63mm dia with Cast
iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gun
Metal cap and chain as required.
Makes : As per list of recommended brands.
MAT- a Single Headed Gun Metal 1 No 8395
04445

MAT- b Single Headed Stainless Steel 1 No 7475


05608

638 ELEC-9.5.32 Supplying, fixing, testing and commissioning of butterfly valve PN 1.6,
with Bronze / Gun metal seat duly ISI marked complete with Nuts, Bolts,
Washers, gaskets, conforming to IS 13095 of following sizes as required.
Makes : As per list of recommended brands.
MAT- a (a) 250 mm . dia 1 No 13225
04446

201
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b (b) 200 mm . dia 1 No 5635


04447
MAT- c (c) 150 mm dia 1 No 4715
04448
MAT- d (d) 100 mm dia 1 No 3623
04449
MAT- e (e) 80 mm dia 1 No 3335
04450
639 ELEC-9.5.33 Providing, installation, testing and commissioning of dual Plate non -
return valve of following sizes confirming to IS: 5312 complete with
rubber gasket, GI bolts, nuts, washers etc as required.
Makes : As per list of recommended brands.
MAT- a a) 250mm dia 1 No 20700
04451
MAT- b (b) 200 mm dia 1 No 10580
04452
MAT- c (c) 150 mm dia 1 No 7590
04453
MAT- d (d) 100 mm dia 1 No 4025
04454
MAT- e (e) 80 mm dia 1 No 3910
04455
MAT- f (f) 50 mm dia 1 No 2070
04456
640 ELEC-9.5.34 Manufacture, Supply and delivery of CI Wafer Lug type Butterfly Valves
conforming to IS 13095/1991 (Reaffirmed 1998) excluding
transportation, CED and taxes etc., complete. Operation done with worm
actuator ISI marked Rate at Ex-Factory.
Makes : As per list of recommended brands.
MAT- a 250 mm . dia 1 No 17595
04457
MAT- b 200 mm . dia 1 No 12650
04458
MAT- c 150 mm dia 1 No 8050
04459
MAT- d 100 mm dia 1 No 5405
04460
MAT- e 80 mm dia 1 No 4025
04461
MAT- f (50 mm dia 1 No 3220
04462

202
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
641 ELEC-9.5.35 Providing, installation, testing and commissioning of gun metal valves of
following sizes as required.
Makes : As per list of recommended brands.
MAT- a 50 mm dia 1 No 1840
04463
MAT- b 40 mm dia 1 No 1495
04464
MAT- c 32 mm dia 1 No 1351
04465
642 ELEC-9.5.36 Supplying and fixing 63mm dia, 15 mtr long RRL hose pipe with 63mm
dia Male and Female Gun metal / SS couplings duly binded with GI wire,
rivets etc conforming to IS 636 (Type -A) as required.
Makes : As per list of recommended brands.
MAT- a Gun metal 1 No 6475
04466

MAT- b SS couplings 1 No 4830


05609

643 ELEC-9.5.37 Supplying and fixing 63mm dia, 15 mtr long CP hose pipe with 63mm dia
Male and Female Gun metal / SS couplings duly binded with GI wire,
rivets etc conforming to IS 636 (Type -A) as required.
Makes : As per list of recommended brands.
MAT- a Gun metal 1 No 5520
04467

MAT- b SS couplings 1 No 4600


05610

644 ELEC-9.5.38 Supply, installation, testing and commissioning of stainless steel Y –


Stainer fabricated outof 1.6 mm thick SS 304 with following sizes
confirming to IS specifications complete with rubber gasket, GI bolts ,
nuts, washers etc as required.
Makes : As per list of recommended brands.
MAT- a 250mm dia 1 No 21160
04468
MAT- b 200 mm . dia 1 No 19550
04469
MAT- c 150 mm dia 1 No 9200
04470
MAT- d 100 mm dia 1 No 4945
04471
MAT- e 80 mm dia 1 No 4485
04472

203
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
645 MAT- ELEC-9.5.39 Supplying and fixing First -Aid Hose 1 No 7705
04473 Reel with MS construction spray
painted in Post office Red,
Conforming to Is 884 with upto date
amendments, complete with the
following as required.
Makes : As per list of recommended
brands.
a) 36.6 Mtr Long 20mm (Nominal internal) dia water hose Thermoplastic /
Textile reinforced / Rubber braided / Polypropylene Type - 2 as per
IS:12585
b) 20mm (Nominal internal) dia gun metal ball/gate valve and nozzle.

c) Drum and brackets for fixing the equipments on


wall.
d) Connections from riser with 25mm dia stop valve (gun metal) & MS
pipe.
646 MAT- ELEC-9.5.40 Supplying and fixing of hose cabinet 1 No 3335
04474 of size 750mm X 600mm x 250mm
made of No 16 gauge SWG CRCA
sheet with 6mm thick glazed glass
door including necessary locking
arrangement suitable to
accommodate 2 Nos 15 mtr long
Hose pipe, 1 No branch pipe,
mounted on wall OR raised brick
platform and duly painted with Post
office red externally and white
internally with synthetic enamel paint
complete in all respect, for external
hydrant as required.
Makes : As per list of recommended
brands.
647 ELEC-9.5.41 Supply and fixing 63mm dia Gun metal branch pipe with 20mm (Nominal
internal diameter) size Gun metal / SS nozzle conforming to IS 903,
suitable for instantaneous connection to interconnect hose pipe coupling
as required.
Makes : As per list of recommended brands.
MAT- a Gun metal 1 No 2530
04475
MAT- b SS couplings 1 No 1840
05611

648 MAT- ELEC-9.5.42 Supply and fixing 4 way fire brigade 1 No 9200
04476 connection of cast iron body with 4
Nos Gun metal Male instantaneous
inlet couplings complete with cap and
chain as required for 150mm dia MS
pipe connection, conforming to IS 904
as required.
Makes : As per list of recommended
brands.

204
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
649 MAT- ELEC-9.5.43 Supply and fixing 2 way fire brigade 1 No 6900
04477 connection of cast iron body with 2
Nos Gun metal Male instantaneous
inlet couplings complete with cap and
chain as required for 100mm dia MS
pipe connection, conforming to IS 904
as required.
Makes : As per list of recommended
brands.
650 MAT- ELEC-9.5.44 Supply and fixing air vessel made of 1 No 16445
04478 250 mm dia, 8 mm thick MS sheet,
1200mm in height with air release
valve on top and flanged connection
to riser, drain arrangement with 25mm
dia Gun metal wheel valve, with
required accessories, pressure gauge
and painting with synthetic enamel
paint of approved shade as required.
651 MAT- ELEC-9.5.45 Providing fixing, testing and 1 No 506
04479 commissioning of 15mm size
quartzoid bulb type sprinklers of rating
68º C. pendent / side wall with
required accessories.
Makes : As per list of recommended
brands.
652 MAT- ELEC-9.5.46 Supply fixing, testing and 1 No 1208
04480 commissioning of UL approved
flexible dropper of 1.5 mtr length with
required accessories
Makes : As per list of recommended
brands.

653 MAT- ELEC-9.5.47 Providing and fixing of Pressure 1 No 2588


04481 Switch in the MS pipe Line including
connection etc as required.
Makes : As per list of recommended
brands.

654 MAT- ELEC-9.5.48 Providing and fixing Flow Switches in 1 No 5520


04482 100mm dia MS pipe.
Makes : As per list of recommended
brands.
655 MAT- ELEC-9.5.49 Providing and fixing Flow Switches in 1 No 7705
04483 150 mm dia MS pipe.
Makes : As per list of recommended
brands.
656 MAT- ELEC-9.5.50 Supply, installation, testing and 1 No 690
04484 commissioning of Bourden type,
stainless steel dial type pressure
gauge with isolation valve and pipe
having calibration of 0-16 kg/cm2.
Makes : As per list of recommended
brands.

205
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
657 MAT- ELEC-9.5.51 Supply, installation, testing and 1 No 1208
04485 commissioning of 25mm dia Gate
valve
Makes : As per list of recommended
brands.
658 MAT- ELEC-9.5.52 Supply, installation, testing and 1 No 667
04486 commissioning of 25mm dia Ball valve
Makes : As per list of recommended
brands.

659 MAT- ELEC-9.5.53 Supply, installation, testing and 1 No 1265


04487 commissioning of 25 / 20mm dia Air
Release Valve
Makes : As per list of recommended
brands.
ELEC-9.5.54 Supply, installation, testing & commissioning of sprinkler flexible pipe (UL
Listed) of stainless steel complete with 15 NPT on reducer thread with
maximum working pressure of 175 PSI test pressure of 875 PSI (Burst)
with branch line (Inlet) 25mm NPT male thread to sprinkler head (Outlet)
15mm NPT female thread with reducer, nipple, 2 side brackets, center
bracket, stockbar of following sizes complete as required.
Makes : As per list of recommended brands.
MAT- a 750mm to 800 mm 1 No 1035
04488
MAT- b 1000 mm to 1200 mm 1 No 1208
04489
MAT- c 1500 mm 1 No 1438
04490
660 ELEC-9.5.55 Providing, fixing, testing & commissioning of installation control valve of
cast iron body,brass/bronze working parts comprising of water motor
alarm, bronze seat clapper, clapper arm and hydraulically driven
mechanical gong bell to sound continuous alarm when the wet
riser/sprinkler system activates, pressure gauges, emergency releases,
strainer, pressure switch, cock valve complete with drain valve and
bypass, test control box, ball valves, MS pipe of required size, flanges,
orifice plate, gasket etc of follwing sizes as required :
Makes : As per list of recommended brands.

MAT- a 80mm dia 1 No 41400


05612
MAT- b 100mm dia 1 No 43700
05613
MAT- c 150mm dia 1 No 46000
04491
661 ELEC-9.5.56 Supplying, installing, testing and commissioning of CI body Foot Valve
with brass strainer with necessary flanges, nuts and bolts etc., complete
on to the suction line.
Makes : As per list of recommended brands.

206
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- a a) 200mm nominal dia 1 Ea 25645


04492
MAT- b b) 150mm nominal dia 1 Ea 13800
04493
MAT- c c) 100mm nominal dia 1 Ea 7705
04494
MAT- d d) 80mm nominal dia 1 Ea 5290
04495
ELEC-9.5.57 Supply and laying of 300mm dia NP2 RCC Hume pipe with Collars for
Road crossings -As per Civil SoR
662 ELEC-9.5.58 Supplying and wrapping the anticorrosive material for buried pipes with
coating of Primer and wrapping with 4 mm thick polymer corrosion
resistant tape as per IS : 10221 with 15 mm overlap as per specificatios.
Makes : As per list of recommended brands.

MAT- a a) 200mm nominal dia 1 Mtr 460


04496
MAT- b b) 150mm nominal dia 1 Mtr 345
04497
MAT- c c) 100mm nominal dia 1 Mtr 311
04498
MAT- d d) 80mm nominal dia 1 Mtr 265
04499
663 MAT- ELEC-9.5.59 Supply, fabricating , installing 1 Kg 72
04500 structural steel supports for fixing all
sizes of MS pipes from ceiling / wall
with MS Channels, Angles, Flats,
Rods, as required at site with anchor
fasteners, Clamps, threaded rods,
nuts, bolts,washers etc complete with
painting.
MAT- ELEC-9.5.60 Fabrication ,transportation and supply 1 No 23000
08784 of fully outdoor type wall
mounted/floor mounted automatic
control panel board with IP-66
protection for 3 phase 7.5 H.P. Motor
of Booster Pump set of size 600x
600x 250mm made of 18 SWG CRCA
sheet steel enclosure, 14 SWG
mounting plate for cable entry
fabricated , painted with two coats of
Red oxide primer and two coats of
Grey paint, lock and key
arrangements two side lovures with
weld mesh inside and mounted on

207
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

suitable angle frame work of 450mm


height on a PCC pedestal over the
terrace consisting of the following
equipment/ components with all
internal wiring for power and control
circuits and control wiring from
sensors like pressure switches etc.,
using copper FRLS cables of suitable
size and capacity and cable clamp etc
complete with DOL Starter of
including cost of all materials and all
labour charges, transportation etc.,
complete for finished item of work.
(Panel shall be fabricated from
reputed and branded manufacturers
approved by dept and having CPRI
approval with CPRI test certificates).
Makes : As per list of recommended
brands.
1) Supply & Fixing of DOL Starter
suitable for 7.5 HP Pump Motor - 1 No
2) Supply and Fixing of (0-500) V
range Volt meter on existing panel,
making connection by PVC insulated
copper conductorwith PVC
sleeves/channel etc.,as required.-1
No
3) Supply and Fixing of CT operated
direct reading type Ammeter, below
500A, on existing panel , making
connection by PVCinsulated copper
conductor with PVC sleeves/channel
etc. as required - 1 No
4) Supply and Fixing of selector
switch for Voltmeter & Ammeter (4
position) including making connection
etc. as required.- 2 No
5) Supply and Fixing of 240/220 V,
LED (22.5 mm dia) Pilot indication
lamps Red, Yellow & Bue Colour with
integral circuit,terminal block,
including connection etc. as required -
3 No
6) Supply and Fixing of Single Phase
Preventor of suitable range - 1No.
7) Supply and fixing of ISI Mark
suitable capacitor
8) Supply and Fixing of MPCB (Motor
Protection Circuit Breaker) suitable for
7.5 HP Motor, Icu=50 KA with
adjustable thermal and magnetic
release Panel Mounted
9) Supply and Fixing of Non-
Luminious type, ON/OFF/TRIP push
button actuators and integral contact
block of dia. 22.5 mm
including making connection etc. as

208
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

required.
10) Supply and Fixing of AC operated
heavy duty 230 /440 Volt power
contactor conforming to IS:13947-4-
1/IEC:947-4-1 having provision of
mechanical interlocking, Din rail
mounting type including making
connections, testing etc. as required.
- 3 pole, 35-40A AC3 Rating,
Contactor - 1 No
11) Supply and Fixing of 24 V DC
,Aux Contactor with 2 NO+2NC
Contacts with suitable NO+NC ADD
on Block
12) Supply and Fixing of thermal over
load relay with built in single phase
protection and having at least 1NO &
1NC contacts,manual /auto reset
facility including making connection
testing etc. as required - 1 No
13) Supply and Fixing of Current
Transformer, upto 150 / 5 Ratio , 10
VA , class 1 accuracy with all
necessary support inexisting panel
including connection etc. as required -
3 No
Control & Power wiring with suitable
size of approved make FRLS PVC
flexible copper wires and from
pressure sensors etc., , Earth Bus
Bar, Door Loop earhings, Ferrules,
danger plate, door locks, mounting
arrangements with 40x40x6mm MS
angle iron frame, PCC and masonary
work, painting for MS angle frame with
red oxide and enamel paint etc., and
all other accessories including all
labour charges etc with connections
for finished item of work including
transportation charges
MAT- ELEC-9.5.61 Providing and fixing of gun metal fire 7140.00
08785 Brigade Suction Hose coupling (Draw-
out Connection) with nut for female
coupling as per
IS:902- 1974 complete with 100 mm
dia. G.I. Suction pipe and 100 mm dia.
1No. C.I. Foot valve flanged (to be
connected to static water tank).
Makes : As per list of recommended
brands.
MAT- ELEC-9.5.62 Providing, installation, testing & 505.00
08786 commissioning of water curtain nozzle
15mm dia nickel chrome plated brass,
BSPT, K-factor
as per design consideration complete
as required.

209
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Makes : As per list of recommended


brands.

MAT- ELEC-9.5.63 Supplying and fixing orifice plate 987.00


08787 made out of 6 mm thick stainless steel
(Grade 304) with orifice of required
size to be fitted between flange&
landing valve of external and internal
hydrants to reduce pressure at the
outlet to the level of 3.5 kg/cm2
complete as required.
Makes : As per list of recommended
brands.
ELEC-9.5.64 Supply,Installation,testing and
commissioning of stainless steel
puddle flange fabricated out of1.6mm
thick SS 304 confirming to IS
specifications including nuts, bolts and
rubber insertions etc.
Makes : As per list of recommended
brands.
MAT- a 150 mm dia 1 No 6650.00
08788
MAT- b 100mm dia 1 No 5800.00
08789
MAT- c 80 mm dia 1 No 4500.00
08790
MAT- d 65 mm dia 1 No 3000.00
08791
MAT- e 50 mm dia 1 No 2800.00
08792

MAT- ELEC-9.5.65 Supply, Erection, Testing and


08793 commissioning of Sluice valves as per
IS:14846 ( PN 10 Rating, for suction
side of the pumps) and rising spindle
type with flanges, bolts, nuts,
washers, gaskets etc.The valve
shall be fitted with Supervisory
switch for monitoring.
Makes : As per list of recommended
brands.
100mm dia 11000

MAT- ELEC-9.5.66 Supplying, installation, testing &


08794 commissioning of deluge valve (to be
used for water curtains) UL listedwith
wet pilot basic trim assembly for DVA
with test and alarm, drip and drain
valve with water motor gong complete
as required.
Makes : As per list of recommended
brands.
150mm dia 92907

210
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- ELEC-9.5.67 Providing, installation, testing & 5640.00


08795 commissioning of electric release trim
assembly for deluge wall with two way
solelnoid valve, weather proof
operation on 24 volts DC supply
complete as required.
Makes : As per list of recommended
brands.
MAT- ELEC-9.5.68 Providing, installation, testing & 155.00
08796 commissioning of adjustable rosette
plate for 15mm dia in white finish
as per specifications complete as
required.

SECTION 10

10.1 GENERATORS SPECIFICATION

664 ELEC-10.1.1 Supply Installation Testing And commissioning of DG Set complete with
1500 RPM Diesel Engine of suitableBHP & AC Brush less SPDP
Alternator mounted on a common base Frame & coupled through a
flexible coupling or close coupled.
Alternator: It shall be self regulated, self excited and confirms to IS:
13364/1992 or latest version with regulation of +5% from No load to full
load, IP23, with standard Alternator Protection( Over voltage, over speed
& under voltage).
DieselEngine: Itshall have residential silencer, up to 10 M exhaust piping
, electronic / Mechanical governor, Manual & electric Start, Batteries, Fuel
tank & piping, control panel (16 G) with TP MCCB of required rating
(25/36/50 KA) with PLC based Engine controller supplied by OEM,
Ammeter, Voltmeter, Frequency Meter or Multi function meter, Energy
Meter & Hour Meter, Engine instruments panel,AVM and Automatic
Voltage Regulator. The diesel engine shall be capable of providing 10%
over load for 1 Hr for every 11 Hrs of continuious running at full load.The
DG set shall be supplied with initial filling of fuel,lube oil, coolant oil as per
OEM specifications and shall be tested at site.
Accoustic Enclosure: Weatherproof, powder coated Accoustic
enclosure for DG set for sound attenuation fabricated from 1.6 mm CRCA
sheet steel (structure) with side wall fabricated from 1.6 mm CRCA sheet
and filled with foam as per CPCB norms latest amendments & IS 8183
.The doors are fabricated from 1.6 mm CRCA sheet packed with
accoustic material, floor of MS chequrred plate 5.0 mmthick, All doors/
opening are sealed with neoprene/ EPDN gaskets.
The DG Set shall be maintained for two years after commissioning by the
supplier including regular servicing, cost of consumables etc complete as
specified by the OEM along with warranty for two years.
The enclosure has built in fuel tank, residential silencer (isolated from
main DG chamber) with protection and tripping of DG set against
temperature of more than 50 °C. All controls for operation of DG set are
from outside the enclosure with DG control panel having processor based
genset monitoring and control system MCCB/ACB Ammeter, voltmeter,
Pf meter, frequency meter, KWH meter, Ind. Lamps etc. mounted inside
enclosure , visible and accessible from outside. The enclosure should be
suitable for following capacity DG sets and alternator.Noise level is less
than 75 db (A) at a distance of 1 Mtrs as per CPCB-II norms,complete in
all respect of following capacity :

211
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Radiator Cooled and Turbocharged

MAT- a 15 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 340000


04501
MAT- b 30 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 440000
04502
MAT- c 40 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 548000
04503
MAT- d 62.5kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 630000
04504
MAT- e 125 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 825000
04505
(a to e) Makes : As per list of recommended
brands.
MAT- f 160 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 1080000
04506

g DELETED 1 No

MAT- h 250 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 1550000


04508
MAT- i 320 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 2250000
04509
MAT- j 380 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 2870000
04510
( f to j) Makes : As per list of recommended
brands.
MAT- k 500kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 3150000
04511
MAT- l 625 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 3800000
04512
MAT- m 750 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 4730000
04513
MAT- n 1000 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 5700000
04514
MAT- o 1250 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 7700000
04515
MAT- p 1500 kVA at 0.8 pf 415V 50Hz 3-Ø 1 No 8740000
04516
( j to p) Makes : As per list of recommended
brands.

212
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
665 ELEC-10.1.2 Supply Installation Testing and Commissioning of AUTO MAINS
FAILURE (AMF) Panel with IP 52 protection, fabricated from CRCA
sheet steel 2mmThick , Powder coated finish , Engine START & STOP
commands,control RELAYS, selector switches for Ammeter &
Voltmeter, Ammeter & Voltmeter ,4pole MCCBs for EB Supply and DG
Supply of required rating and breaking capacity,Automatic battery
charger(External charger for DG) Control & Power Contactors, Timers,
Electronic Hooter ,Visual & Alarm indication for faults, UPS, operator
interface panel complete in all respect suitable for following capacity DG
sets:
PLC based AMF Panel

MAT- a 25 to 40 KVA 1 No 75000


04517
MAT- b 50 to 63.5 KVA 1 No 110000
04518
MAT- c 80 to 160 KVA 1 No 155000
04519
MAT- d 180 to 250 KVA 1 No 210000
04520
MAT- e 320 to 500 KVA 1 No 260000
04521
Electro-Mechanical Relay Based
AMF Panel
MAT- f 25 to 63.5 KVA 1 No 55000
04522
MAT- g 80 to 180 KVA 1 No 92500
04523
MAT- h 200 to 500 KVA 1 No 135000
04524
666 MAT- ELEC-10.1.3 Supply and fixing of Thermal Mtr 251
04525 Insulation With Asbestos Rope for
Exhaust pipe
667 MAT- ELEC-10.1.4 Supply and fixing of Thermal Mtr 1247
04526 Insulation With Rock/Glass Wool
wwith Alluminium cladding (Density -
96 Kg/m3 thickness -50mm) for
Exhaust pipe
SECTION 11

11.1 INVERTERS and ONLINE UPS


SYSTEMS
668 ELEC-11.1.1 Supply and installation of ……. Inverter(home UPS system) pure sine
wave out put, single phase input / Single phase output.
Makes : As per list of recommended brands.
MAT- a 800 VA, 12 V DC 1 No 9350
04527

213
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- b 1400 VA, 24 V DC 1No 13200


04528
MAT- c 2000 VA, 36 V DC 1No 18700
04529
669 ELEC-11.1.2 Supply installation Testing and commissioning of .......... KVA on line
UPS system confirms to IS 16242(Part-I):2014 and IEC 60240-1 : 2008
with IGBT technology pure sine wave out put, double conversion with
auto and manual static by pass switch single phase input / Single phase
output.
Makes : As per list of recommended brands.
MAT- a 2.0 KVA , 72/96VDC 1 No 26400
04530
MAT- b 3.0 KVA , 72/96 VDC 1 No 36300
04531
MAT- c 3.0 KVA , 72/96 VDC with Isolation 1 No 41580
04532 Transformer

MAT- d 6.0 KVA , 192/240 VDC with Isolation 1 No 71500


04533 Transformer

MAT- e 7.0 KVA , 192/240 VDC with Isolation 1 No 86350


04534 Transformer

MAT- f 10.0 KVA , 192-240 VDC with 1 No 103950


04535 Isolation Transformer

670 ELEC-11.1.3 Supply installation Testing and commissioning of .......... KVA on line
UPS system as per IEC 62040-I(Safety) ,IEC 62040-3(Performance) for
critical IT solutions ,fully digital IGBT Converter and Inverter ,with Internal
/External isolation transformer from DC to AC, PWM, pure sine wave out
put, double conversion ,output pf 0.9, with parallelling facility , standard
communicaton features/options auto and manual static by pass switch
three phase input / Three phase output. Accoustic level shall be less
than 58dB at 1 mtr distance.
Makes : As per list of recommended brands.
MAT- a 10.0 KVA 312/360 V DC 1 No 181500
04536
MAT- b 15.0 KVA 312/360 V DC 1 No 198000
04537
MAT- c 20.0 KVA 312/360 V DC 1 No 231000
04538
MAT- d 30.0 KVA 312/360 V DC 1 No 302500
04539
MAT- e 40.0 KVA 312/360 V DC 1 No 385000
04540

214
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
671 ELEC-11.1.4 Supply installation Testing and commissioning of .......... KVA on line
UPS system as per IEC 62040-I(Safety) ,IEC 62040-3(Performance) for
critical IT solutions ,fully digital IGBT Converter and Inverter ,with Internal
/External isolation transformer from DC to AC, PWM, pure sine wave out
put, double conversion ,output pf 0.9, with parallelling facility , standard
communicaton features/options auto and manual static by pass switch
three phase input / Three phase output. Accoustic level shall be less
than 58dB at 1 mtr distance.
Makes : As per list of recommended brands.
MAT- a 60 KVA 1 No 715000
04541
MAT- b 80.0 KVA 1 No 935000
04542
MAT- c 100.0 KVA 1 No 1083500
04543
MAT- d 120.0 KVA 1 No 1229800
04544
MAT- e 160.0 KVA 1 No 1372800
04545
MAT- f 200.0 KVA 1 No 1401400
04546
672 MAT- ELEC-11.1.5 Supply and providing of UPS cum 1 No 1650
04547 battery rack up to 4 batteries

673 MAT- ELEC-11.1.6 Supply and providing of battery rack 1 No 3300


04548 for 5 to 10 batteries (42 AH)

674 MAT- ELEC-11.1.7 Supply and providing of battery rack 1 No 5500


04549 upto 11 to 20 batteries (42 AH)

675 MAT- ELEC-11.1.8 Supply and providing of battery rack 1 No 9900


04550 upto 20 to 30 batteries (65 & 100 AH)

676 MAT- ELEC-11.1.9 Supply and fixing of 12V 26 AH SMF 1 No 3520


04551 battery with 3 years Warrenty,
including wire leads ,connections etc
complete.,.
Makes : As per list of recommended
brands.
677 MAT- ELEC-11.1.10 Supply and fixing of 12V 42 AH SMF 1 No 6270
04552 battery with 3 years Warrentyincluding
wire leads ,connections etc complete..
Makes : As per list of recommended
brands.
678 MAT- ELEC-11.1.11 Supply and fixing of 12V 65 AH SMF 1 No 7920
04553 battery with 3 years warrenty including
wire leads ,connections etc complete.,
Makes : As per list of recommended
brands.

215
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
679 MAT- ELEC-11.1.12 Supply and fixing of 12V 100 AH SMF 1 No 11484
04554 battery with 3 years warrenty including
wire leads,connections etc complete.,
Makes : As per list of recommended
brands.
680 MAT- ELEC-11.1.13 Supply and fixing of 12V 120/130 AH 1 No 12276
04555 SMF battery with 3 years warrenty
including wire leads,connections etc
complete., .
Makes : As per list of recommended
brands.
681 MAT- ELEC-11.1.14 Supply and fixing of 12V, 150 AH 1 No 17160
04556 SMF battery with 3 years
warrentyincluding wire
leads,connections etc complete.,
Makes : As per list of recommended
brands.
682 MAT- ELEC-11.1.15 Supply and fixing of 12V, 200 AH 1 No 23760
04557 SMF battery with 3 years warrenty
including wire leads ,connections etc
complete.,
Makes : As per list of recommended
brands.
683 ELEC-11.1.16 Supply and fixing of 12V, 120 AH MF 1 No deleted
battery including wire leads

684 MAT- ELEC-11.1.17 Supply and fixing of 12V, 150 AH MF 1 No 13200


04559 battery including wire leads
Makes : As per list of recommended
brands.

SECTION - 12

12.1 TEMPORARY ILLUMINATION

685 HIR- ELEC-12.1.1 Hire charges for Temporary 1 No 39


00241 illumination, consisting of 20W LED
tube light complete with required
switchgears with continuous earth
wire duly erected and dismantled with
required scaffolding including cost and
conveyance of all materials and
labour charges etc., complete for one
day.
686 HIR- ELEC-12.1.2 Hire charges for Temporary 1 No 321
00242 illumination, consisting of flood light
fitting 1000/500W complete halogen
fitting with lamp, holders, mains and
required switchgears with
continuous earth wire erected
and dismantled with required
scaffolding for one day.

216
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
687 HIR- ELEC-12.1.3 Hire charges for Temporary 1 No 377
00243 illumination, consisting of 400W
Metalhalide flood light fitting with
lamp,holders,mains and required
switchgears with continuous earth
wire erected and dismantled with
requird scaffolding for one day.

688 HIR- ELEC-12.1.4 Hire charges for Temporary 1 No 413


00244 illumination, consisting of 400W Metal
Halide flood light fitting with Coloured
lamp (Blue / Pink / Yellow / Red
etc.,)holders,mains and required
switchgears with continuous earth
wire erected and dismantled with
required scaffolding for one day.

689 HIR- ELEC-12.1.5 Hire charges for Temporary 1 No 399


00245 illumination, consisting of 54 W LED
RGB Parcan light fitting non integral,
weather proof die cast alluminium
housing with IP66 protection with
control gear box, conrol gear with
required cables, holder, mains duly
errected with required scaffolding and
dismantled on exising poles including
cost and conveyance of all materials
and labour charges etc., complete for
one day.
690 HIR- ELEC-12.1.6 Hire charges for providing temporary 1 No 460
00246 illumination consisting of flood light
fitting 150/200 W complete LED fitting
with lamp, complete required
switchgear erected and dismantled
with using scaffolding for one day.

691 HIR- ELEC-12.1.7 Hire charges for temporary 1000 Nos 1441
00247 illumination consisting of strip lights
8mm LED lights of various colors
(Navar Patta) complete with holders,
required wire leads erected and
dismantled including required
scaffolding and T&P including cost
and conveyance of all materials and
all labour charges etc., complete for
one day.
692 HIR- ELEC-12.1.8 Hire charges for temporary 1000 Nos 990
00248 illumination consisting of white color
series lights with miniature lamps of
8mm LED lights with required wire
leads erected and dismantled
dismantled including required
scaffolding and T&P including cost
and conveyance of all materials and
all labour charges etc., complete for

217
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

one day.

693 HIR- ELEC-12.1.9 Hire charges for temporary 1000 Nos 1227
00249 illumination consisting of LED RGB
pixel series strip lights 8mm LED
lights of various colors (Navar Patta)
complete with holders, required wire
leads erected and dismantled
including required scaffolding and
T&P including cost and conveyance of
all materials and all labour charges
etc., complete for one day.
694 HIR- ELEC-12.1.10 Hire charges for temporary 1000 Nos 787
00250 illumination consisting LED,RGB pixel
series lights with miniature lamps of
8mm LED lights with required wire
leads erected and dismantled
including required scaffolding and
T&P including cost and conveyance of
all materials and all labour charges
etc., complete for one day.
695 HIR- ELEC-12.1.11 Hire Charges for National Flag of size 1 No 5500
00251 8"x4"Comprising LED's with required
wire leads and switch gear etc.,
complete for one day.

696 HIR- ELEC-12.1.12 Hire charges for supply and 1 No 176


00252 maintaining of oscillating type
pedestal air circulators 600/900 mm
connected with necessary mains,
required switchgears with
continuous earthing maintaining
the same during the function and
including dismantling for one day.

697 HIR- ELEC-12.1.13 Hire charges for supply and 1 No 162


00253 maintaining of oscillating type
pedestal fan 16" (400 mm) or
ceiling fan connected with
necessary mains, required
switchgears with continuous earthing
maintaining the same during the
function and including dismantling for
one day.
698 HIR- ELEC-12.1.14 Hire charges for Providing 1.1KW , 1 No 1364
00254 24500 m3/Hr Air cooler and required
materials with necessary mains
switch gear with continues earth lead
during function duly removing
including cost and conveyance of all
materials and labour charges etc.,
complete for one day.

218
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
699 HIR- ELEC-12.1.15 Hire charges for supply and 1 No 162
00255 maintaining of heavy duty exhaust fan
18" or 24" connected with necessary
mains, required switchgears with
continuous earthing maintaining the
same during the function and
including dismantling for one day.
700 HIR- ELEC-12.1.16 Hire charges for supply and 1 No 68
00256 maintaining of plug points with 16A/6A
5 Pin socket and swich with
necessary mains, required
switchgears and continuous earth
connection for one day.
701 HIR- ELEC-12.1.17 Hire charges for supply and 1 No 550
00257 maintaining 280 litres capacity
refrigerator complete with M.S. stand
if necessary connected with mains,
switchgear and continuous earthing
maintaining the same during the
function and including dismantling for
one day.
702 HIR- ELEC-12.1.18 Hire charges for supply and 1 No 1210
00258 maintaining 120/150 liter capacity
water cooler with water filter (candle
type or UV tube) with M.S. stand
complete with minor plumbing work if
necessary connected with mains,
required switchgears and continuous
earthing maintaining the same during
the function and including dismantling
for one day.
703 HIR- ELEC-12.1.19 Hire charges for supply and 1 No 396
00259 maintaining 20"/24" colour
television with multi channel tuner,
connected with necessary mains,
required switchgearswith continuous
earthing maintaining the same during
the function and including dismantling
for one day.

704 HIR- ELEC-12.1.20 Providing and maintaining temporary 1 No 825


00260 LCD/LED colour T.V. (32''to 42'' size)
and positioning at site with required
cabling as perdirection of authority,
duly connecting and testing for one
day.
705 HIR- ELEC-12.1.21 Hire charges for supply and 1 No 110
00261 maintaining 6V/10V with 20/40 Watt
fluorescent emergency lamp
connected with necessary mains,
required switchgears and continuous
earthing maintaining the same during
the function and including dismantling
for one day.

219
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
706 HIR- ELEC-12.1.22 Hire charges for supply and 1 No 5610
00262 maintaining digital projector with
spring loaded white screen
connected with necessary mains,
required switchgears and maintaining
the same during the function
including dismantling for one day.
707 HIR- ELEC-12.1.23 Hire charges for providing 1.5/2.0 1 No 4830
00263 Ton capacity split type air
conditioning unit complete with
temporary stand and fabrication work
and required material to
achieve cooling temperature
connected along with necessary
mains, required switchgears and
continuous earthing maintaining the
same during the function and
including dismantling for one day.

708 HIR- ELEC-12.1.24 Hire charges for providing 3.5 Ton 1 No 5520
00264 capacity tower type air conditioning
unit complete with temporary
stand and fabrication work and
required material to achieve
cooling temperature connected
along with necessary mains,
required switchgears and continuous
earthing maintaining the same during
the function and including dismantling
for one day.

709 HIR- ELEC-12.1.25 Hire charges for providing 4.5 Ton 1 No 6325
00265 capacity tower type
air conditioning unit complete with
temporary stand and fabrication work
and required material to
achieve cooling temperature
connected along with necessary
mains,required switchgears and
continuous earthing, maintaining the
same during the function and
including dismantling for one day.

710 HIR- ELEC-12.1.26 Hire charges for providing 1 No 7475


00266 6.5Ton/7.5Ton capacity tower typeair
conditioning unit complete with
temporary stand and fabrication work
and required material to
achieve cooling temperature
connected along with necessary
mains,required switchgears and
continuous earthing, maintaining the
same during the function and
including dismantling for one day.

220
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
711 HIR- ELEC-12.1.27 Hire charges for providing, 1 No 8250
00267 maintaining and operating
temporary public address system on
hire consisting 02 Nos. solid state
heavy wattage amplifier 250 watts (
one for working and another for stand
by emergency ) working on AC /
generator and 24 volt car battery
supply, 06 Nos. of matching of 100
volt line (200 watts) box type
speakers/sound column, 02 Nos
super sensitive microphone with
suitable size of microphone holding
stand. The system shall be in a fully
automatic change over operation in
case of failure of supply for one day.

712 HIR- ELEC-12.1.28 Hire charges for providing and 1 No 385


00268 maintaining temporary additional box
type speaker of 100 Volt line ( 100
watts ) for one day.

713 HIR- ELEC-12.1.29 Hire charges for providing and 1 No 2673


00269 maintaining temporary cordless (
Hand type or lape type ) super
sensitive HUF microphone (1 no stand
by) for one day.

714 HIR- ELEC-12.1.30 Providing temporary line matching 1 No 220


00270 transformer (40-XT) for speakers
having distance more than 60 Mtrs
from Amplifiers and maintaining the
same for one day.
715 HIR- ELEC-12.1.31 Hire charges for providing, 1 No 2750
00271 maintaining and operating fingertip
switcher of 8 ways to operate the
public address system between dias
and participants in the hall with
necessary cabling, wiring etc for one
day.
716 HIR- ELEC-12.1.32 Hire charges providing and 1 No 1100
00272 maintaining all in one desktop PC with
following configuration Intel TM
second generation core i3 G630,2GB
DDR3 RAM, 1TB HARD DISK, DVDR
W optical drive 20'' LED screen, web
camera, wifi, bluetooth, keyboard
and mouse, media card reader etc
for one day.

717 HIR- ELEC-12.1.33 Hire charges providing and 1 No 330


00273 maintaining Laser Printer, resolution
(in dpi) mono 600, paper size A4, print
speed in PPM (A4 size) 25, Port: 1

221
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

USB, memory (in MB): NA network


card 10/100:YES, Duplexing: YES etc
for one day.

718 HIR- ELEC-12.1.34 Hire charges for providing and 1 No 1815


00274 maintaining 1 KVA on line UPS pure
sine wave suitable for 30 minutes
battery backup to provided computer
with necessary interconnecting
cabling, wiring etc for one day.
719 HIR- ELEC-12.1.35 Hire cahres for providing and 1 No 1100
00275 maintaining temporary 1400 VA to
1600 VA digital pure sine wave
Invertor based on IGBT technology
suitable for 120 minutes battery
backup to electrical installation with
necessary interconnecting cabling,
wiring etc for one day.

720 HIR- ELEC-12.1.36 Hire charges for supply and fixing 1 No 1481
00276 distributation main board consisiting of
400A/250A 4pole MCCB with bus bar
arrangement 12 Nos 63A fuse units
as out going including conveyance of
all materials and all labour charges
etc., complete for one day.
721 HIR- ELEC-12.1.37 Hire charges for Supply & Fixing of 1 No 1511
00277 Distribution board of load main board
consisting of 400A MCCB 4 pole with
Busbar arrangement and 12 Nos 63A
fuse units as out going including
conveyance of all materials and all
labour charges etc., complete for one
day.
722 HIR- ELEC-12.1.38 Hire charges for Supply & Fixing of 1 No 1450
00278 Distribution board of load main board
consisting of 250A MCCB 4 pole with
Busbar arrangement and 12 Nos 63A
fuse units as out going including
conveyance of all materials and all
labour charges etc., complete for one
day.
723 HIR- ELEC-12.1.39 Hire charges for supply and 1 No 336
00279 maintaining towards supply and fixing
of 200A 4 pole Changeover / TPN
switches including erection and
dismantling and cost and conveyance
of all materials and labour charges
complete for one day.
724 HIR- ELEC-12.1.40 Hire charges for supply and fixing 1 No 1432
00280 distributation main board consisiting of
400A/250A 4pole change over switch
with bus bar arrangement 12 Nos

222
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

63A fuse units as out going including


conveyance of all materials and all
labour charges etc., complete for one
day.
725 HIR- ELEC-12.1.41 Hire charges for supply and fixing 1 No 1383
00281 distributation main board consisiting of
250A 4pole change over switch with
bus bar arrangement 12 Nos 63A
fuse units as out going including
conveyance of all materials and all
labour charges etc., complete for one
day.
726 HIR- ELEC-12.1.42 Hire charges for Supply and 1 No 1276
00282 maintaining towards suppy and fixing
of 4 way TPN DB with 1 No 125 TP
MCCB and 12Nos 6-32A 10kA SP
MCBs including erection and
dismantling and cost and conveyance
of all materials and labour charges
complete for one day.
727 HIR- ELEC-12.1.43 Hire charges for Supply and 1 No 1321
00283 maintaining towards suppy and fixing
of 6 way TPN DB with IP-43
Protection with 1 No 125 FP MCCB
and 18Nos 6-32A 10kA SP MCBs
including erection and dismantling and
cost and conveyance of all materials
and labour charges complete for one
day.
728 HIR- ELEC-12.1.44 Hire charges for providing industrial 1 No 510
00284 type panel board consisting of bus bar
chamber with 200/250 amps incoming
TP/MCCB as incomers switch, 12 nos
63 amps fuse unit, earth wire erected
and dismantled all accessories etc.,
complete for one day.
729 HIR- ELEC-12.1.45 Hire charges for supply and installing 1 Mtr 6
00285 and maintaining towards supply and
run of 1 of 6/10 Sq.mm WPTC / 2 of
WPSC / VIR cable with necessary
terminations etc. complete for one
day.
730 HIR- ELEC-12.1.46 Hire charges for supply and installing 1 Mtr 28
00286 and maintaining towards supply and
run of 16 Sq.mm to 35 Sqmm x 3 1/2
core cable / 4 of single core 16
Sqmm to 35 Sqmm cable with
necessary terminations etc. complete
for one day.
731 HIR- ELEC-12.1.47 Hire charges for supply and installing 1 Mtr 30
00287 and maintaining towards supply and
run of 50Sqmm to 95 Sq.mm x 31/2
core cable / 4 of single core 50Sqmm
to 95Sqmm cable with necessary

223
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

terminations etc. complete for one


day.
732 HIR- ELEC-12.1.48 Hire charges for supply and installing 1 Mtr 29
00288 and maintaining towards supply and
run of 50 Sqmm x 3 1/2 core cable / 4
of single core 50 Sqmm cable with
necessary terminations etc. complete
for one day.

733 HIR- ELEC-12.1.49 Hire charges for supply and installing 1 Mtr 31
00289 and maintaining towards supply and
run of 95 Sq.mm x 31/2 core cable / 4
of single core 95Sqmm cable with
necessary terminations etc. complete
for one day.
734 HIR- ELEC-12.1.50 Hire charges for supply and installing 1 Mtr 32
00290 and maintaining towards supply and
run of 120 Sq.mm x 3 1/2 core cable /
4 of single core 120 Sq.mm cable
with necessary terminations etc.
complete for one day.
735 HIR- ELEC-12.1.51 Hire charges for supply and installing 1 Mtr 35
00291 and maintaining towards supply and
run of 185 Sq.mm x 3 1/2 core cable /
4 of single core 185 Sq.mm cable
with necessary terminations etc.
complete for one day.
736 HIR- ELEC-12.1.52 Hire chages for Supply and erection of 1 No 1728
00292 MS Single pole structure of 20' (6.00
Mtrs.) with necessary cross arms and
hardware materials for fixing halogen /
Metal halide fittings etc., and
dismantling and cost and conveyance
of all materials and all labour charges
complete for one day.
737 HIR- ELEC-12.1.53 Hire charges for Supply and erection 1 No 2292
00293 of 4 pole structure of 4 of 25' (7.50
Mtrs.) GI pipe of 63/80mm dia with
necessary cross arms and hardware
materials for fixing halogen / Metal
halide fittings with suitable earthing
arrangements and dismantling and
cost and conveyance of all materials
and all labour charges complete for
one day.
738 HIR- ELEC-12.1.54 Hire charges for Supply and erection 1 No 3447
00294 of 6 pole structure of 6 of 25' (7.50
Mtrs.) GI pipe of 63/80mm dia with
necessary cross arms and hardware
materials for fixing halogen / Metal
halide fittings with suitable earthing
arrangements and dismantling and
cost and conveyance of all materials
and all labour charges complete for

224
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

one day.

739 HIR- ELEC-12.1.55 Hire charges for providing, 1 Job 7854


00295 commissioning and maintaining
CCTV system with 8 channel NVR, IP
video/audio input - 1 no, IP based 2.0
MP, Full HD, IR IP dome camera - 2
nos, IP based 2.0 MP, Full HD, IR IP
PTZ camera - 2 nos, 2TB Hard Disk -
2 no, 32'' Full H D professional
Display - 1 no, 8 port PoE Switch - 1
no, Power supply unit to camera - 1
no, On Line UPS - 1 no with
necessary mains, switchgears for one
day
740 HIR- ELEC-12.1.56 Hire charges for providing, 1 No 979
00296 commissioning and maintaining IP
based 2.0 MP, full HD, IR IP dome /
bullet camera with necessary Cat 6
cables etc., for one day.

741 HIR- ELEC-12.1.57 Hire charges for providing, 1 No 2706


00297 commissioning and maintaining IP
based 2.0 MP, Full HD, IR IP PTZ
camera with necessary Cat 6 cables
etc., for one day.

Note:- 1) The Rates for all the items are for


one glowing / working day

2) Allow 50% of the rate for each day


upto 3 days (i.e, 2nd and 3rd day)
(Except items 12.1.23 to 12.1.26) .
3) For each additional day after 3
days, but not exceeding 15 days,
allow 25% rate.
4) For more than 15 days allow 10%
per day but total rental charges shall
not exceed 80% of the capital cost of
the item.
5) For item no. 12.1.22 the rates of
projector is for 1 function or for max.
period of 1 day whichever is more,
including transportation, connections
with projector, operator till completion
of function.
6) For item No 12.1.23 to 12.1.26, the
rate is for one day, For subsequent
days (i.e, 2nd to 8th day) allow 75%
of the above rate, after 8th day allow
50% the rate.

225
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

12.2 Hiring of Generators


742 HIR- ELEC-12.2.1 Hire charges for supplying and 1 No 7849
00298 maintaining 62.5KVA, 415V, 50 cycles
A.C.Generating set with acoustic
enclosure as per IS Specification with
DCM 4 Wheeler Vehicle with all
standard accessories such as control
panel, batteries etc. complete
excluding cost of fuel, for one day.
743 HIR- ELEC-12.2.2 Hire charges for supplying and 1 No 8970
00299 maintaining 125KVA 415V 50 cycles
A.C.Generating set with acoustic
enclosure as per IS Specification with
DCM 4 Wheeler Vehicle with all
standard accessories such as control
panel, batteries etc. complete
excluding cost of fuel, for one day.
744 HIR- ELEC-12.2.3 Hire charges for supplying and 1 No 12564
00300 maintaining 250KVA 415V 50 cycles
A.C.Generating set with acoustic
enclosure as per IS Specification with
DCM 4 Wheeler Vehicle with all
standard accessories such as control
panel, batteries etc. complete
excluding cost of fuel, for one day.

Note:- 1) Above rates are applicable for per


one day only.
2) For subsequent days the above
rate shall be reduced by 25% after 8th
day reduce the rate by 50%
3) Diesel cost will be paid extra for
running hours at the prevailing rates.

4) For test run,. The minimum


requirement of the fuel shall be born
by the contractor.
5) The D.G set should be in good
conditin and the life of set shall not be
beyond 10 years.
13.1 LIFTS (New Installation)

745 MAT- ELEC-13.1.1 Supply,Installation,Testing and 1Job 1059400.00


08534 Commissioning of Electric Traction
Passenger Lift of Makes : As per list
of recommended brands.
with
• Rated capacity :- 8
Passenger/544Kg
• Floors :- G+1 floor (2Stops/2
Landings)
• Travel :- 3 to 4.2 mtrs
• Location of Lift Machine:- MRL

226
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

• Rated speed :- 1.0mps VS


• Doors type :- COPO/TOPO Doors
with frame having clear opening of
800 mm wide x 2000 mm high made
from SS 304 grade sheet of 1.5mm,
thick in hairline finish for car and all
landing doors with SS door
architraves/frames
• Lift car enclosure made from SS 304
grade sheet of 1.5mm, thick with
hairline finish with frame made from
MS girders, bracing of adequate size
with minimum safety factor of 5, with
Toe Guard Apron, with necessary
false ceiling with adequate LED lights,
blower/fan for ventilation & SS
chequered plate flooring, handrails,
mirror, emergency light etc.
COP with SS face plate having
metallic push buttons with Braille
Code & luminous indicator around
button with FPI, scrolling UP/DN LED
indicator & with/without attendant key
switch, OWD with audio-visual alarm,
VAS in Telugu & English with
intercom system with telephone
instrument in Lift car, LMR &
FCC/ground floor
Clear Car size of ......mm wide x
......mm deep x ......mm high
• LOP with SS face plate having
recess/surface push button box for all
landings with scrolling UP/DN LED
indicator having metallic push buttons
with Braille Code & luminous indicator
around button with CPI, Lift car arrival
& next travel direction audio-visual
indication at all landings
Lift controller based on
microprocessor/ PLC with VVVF Drive
having closed loop control system,
with IBMS compatible having
necessary port, control panel duly
wired with proper size & strength
copper wire for power & control
circuit, with provision for addition of
floor/control card & allied accessories
control panel having enclosure of
1.5mm CRCA sheet with powder
coating with IP54 Protection class
• ARD complete with necessary SMF
VRLA batteries
• Fireman controller having fireman
switch at fire Landing,
Lift Machine of Gearless PMSM of
suitable kW with Traction pulley,
OSG, electromagnetic brakes, entire

227
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

assembly mounted on adequate size


girders duly fixed on LMR floor/ shaft
walls complete with main/diverter
traction sheaves, suspension wire
ropes/belts of adequate size &
strength
• Other mechanical parts such as 'T'
section adequate size guide rails for
car & counter weight with brackets
fasteners, counter weight frame with
necessary blocks, buffers with
necessary support arrangement, MS
pit ladder etc. erected with necessary
steel work
Minor civil work for alteration if any
and erection of door frames and
accessories, erection buffers, erection
of lift machinery, adequate size core
cuts if required & scaffolding for
erecting guide rails fixing of girders for
mounting lift machine etc. complete as
per specification no. LFT.
•Lift shaft available having clear size
of ......mm wide x
......mm deep. ......mm Pit depth,
………mm Overhead.
746 MAT- ELEC-13.1.2 Supply,Installation,Testing and 1Job 1267300.00
08535 Commissioning of Electric Traction
Passenger Lift of Makes : As per list
of recommended brands.
with
• Rated capacity :- 10
Passenger/680Kg
• Floors :- G+1 floor (2Stops/2
Landings)
• Travel :- 3 to 4.2 mtrs
• Location of Lift Machine:- MRL
• Rated speed :- 1.0mps VS
• Doors type :- COPO/TOPO Doors
with frame having clear opening of
800 mm wide x 2000 mm high made
from SS 304 grade sheet of 1.5mm,
thick in hairline finish for car and all
landing doors with SS door
architraves/frames
• Lift car enclosure made from SS 304
grade sheet of 1.5mm, thick with
hairline finish with frame made from
MS girders, bracing of adequate size
with minimum safety factor of 5, with
Toe Guard Apron, with necessary
false ceiling with adequate LED lights,
blower/fan for ventilation & SS
chequered plate flooring, handrails,
mirror, emergency light etc.
• COP with SS face plate having

228
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

metallic push buttons with Braille


Code & luminous indicator around
button with FPI, scrolling UP/DN LED
indicator & with/without attendant key
switch, OWD with audio-visual alarm,
VAS in Telugu & English with
intercom system with telephone
instrument in Lift car, LMR &
FCC/ground floor.
Clear Car size of ......mm wide x
......mm deep x ......mm high
• LOP with SS face plate having
recess/surface push button box for all
landings with scrolling UP/DN LED
indicator having metallic push buttons
with Braille Code & luminous indicator
around button with CPI, Lift car arrival
& next travel direction audio-visual
indication at all landings
• Lift controller based on
microprocessor/ PLC with VVVF Drive
having closed loop control system,
with IBMS compatible having
necessary port, control panel duly
wired with proper size & strength
copper wire for power & control
circuit, with provision
for addition of floor/ control card &
allied accessories control panel
having enclosure of 1.5mm CRCA
sheet with powder coating with IP54
Protection class
• ARD complete with necessary SMF
VRLA batteries
• Fireman controller having fireman
switch at fire Landing.
• Lift Machine of Gearless PMSM of
suitable kW with Traction pulley,
OSG, electromagnetic brakes, entire
assembly mounted on adequate size
girders duly fixed on LMR floor/ shaft
walls complete with main/diverter
traction sheaves, suspension wire
ropes/belts of adequate size &
strength.
• Other mechanical parts such as 'T'
section adequate size guiderails for
car & counter weight with brackets
fasteners, counter weight frame with
necessary blocks, buffers with
necessary support arrangement, MS
pit ladder etc. erected with necessary
steel work
• Minor civil work for alteration if any
and erection of door frames and
accessories, erection buffers, erection

229
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

of lift machinery, adequate size core


cuts if required & scaffolding for
erecting guide rails fixing of girders
for mounting lift machine etc.
complete as per specification no. LFT.
• Lift shaft available having
clear size of ......mm wide x
......mm deep , ......mm Pit depth, ,
………mm Overhead.
747 MAT- ELEC-13.1.3 Supply,Installation,Testing and 1Job 1353000.00
08536 Commissioning of Electric Traction
Passenger Lift of Makes : As per list
of recommended brands.
with
• Rated capacity :- 13
Passenger/884Kg
• Floors :- G+1 floor (2Stops/2
Landings)
• Travel :- 3 to 4.2 mtrs.
• Location of Lift Machine:- MRL
• Rated speed :- 1.0mps VS
• Doors type :- COPO/TOPO Doors
with frame having clear opening of
900/1000 mm wide x 2000 mm high
made from SS 304 grade sheet of
1.5mm, thick in hairline finish for car
and all landing doors with SS door
architraves/ frames
• Lift car enclosure made from SS 304
grade sheet of 1.5mm, thick with
hairline finish with frame made from
MS girders, bracing of adequate size
with minimum safety factor of 5, with
Toe Guard Apron, with necessary
false ceiling with adequate LED lights,
blower/fan for ventilation & SS
chequered plate flooring, handrails,
mirror, emergency light etc.
COP with SS face plate having
metallic push buttons with Braille
Code & luminous indicator around
button with FPI, scrolling UP/DN LED
indicator & with/without attendant key
switch, OWD with audio-visual alarm,
VAS in Telugu & English with
intercom system with telephone
instrument in Lift car, LMR &
FCC/ground floor
• Clear Car size of ......mm wide x
....mm deep x ......mm high
• LOP with SS face plate having
recess/surface push button box for all
landings with scrolling UP/DN LED
indicator having metallic push buttons
with Braille Code & luminous indicator
around button with CPI, Lift car arrival

230
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

& next travel direction audio-visual


indication at all landings
• Lift controller based on
microprocessor/ PLC with VVVF Drive
having closed loop control system,
with IBMS compatible having
necessary port, control panel duly
wired with proper size & strength
copper wire for power & control
circuit, with provision for addition of
floor /control card & allied accessories
control panel having enclosure of
1.5mm CRCA sheet with powder
coating with IP54 Protection class
ARD complete with necessary SMF
VRLA batteries
• Fireman controller having fireman
switch at fire Landing,
• Lift Machine of Gearless PMSM of
suitable kW with Traction pulley,
OSG, electromagnetic brakes, entire
assembly mounted on adequate size
girders duly fixed on LMR floor/ shaft
walls
complete with main/diverter traction
sheaves, suspension wire ropes/belts
of adequate size & strength
Other mechanical parts such as 'T'
section adequate size guide rails for
car & counter weight with brackets
fasteners, counter weight frame with
necessary blocks, buffers with
necessary support arrangement, MS
pit ladder etc. erected with necessary
steel work
• Minor civil work for alteration if any
and erection of door frames and
accessories, erection buffers, erection
of lift machinery, adequate size core
cuts if required & scaffolding for
erecting guide rails fixing of girders
for mounting lift machine etc.
complete as per specification no. LFT.
• Lift shaft available having clear size
of ......mm wide x
......mm deep, ......mm Pit depth,
………mm Overhead
748 MAT- ELEC-13.1.4 Supply,Installation,Testing and 1Job 1586000.00
08537 Commissioning of Electric Traction
Passenger cum Stretcher/Hospital
Lift of Makes : As per list of
recommended brands.
with
• Rated capacity :- 15
Passenger/1020Kg
• Floors :- G+1 floor (2Stops/2

231
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Landings)
• Travel :- 3 to 4.2 mtrs
• Location of Lift Machine:- MRL
• Rated speed :- 1.0mps VS
• Doors type :- COPO/TOPO Doors
with frame having clear opening of
800/900/1000 mm wide x 2000mm
high made from SS 304 grade sheet
of 1.5mm, thick in hairline finish for
car and all landing doors with SS door
architraves /frames
• Lift car enclosure made from SS 304
grade sheet of 1.5mm, thick with
hairline finish with frame made from
MS girders, bracing of adequate size
with minimum safety factor of 5, with
Toe Guard Apron, with necessary
false ceiling with adequate LED lights,
blower/fan for ventilation & SS
chequered plate flooring, handrails,
mirror, emergency light etc.
COP with SS face plate having
metallic push buttons with Braille
Code & luminous indicator around
button with FPI, scrolling UP/DN LED
indicator & with/without attendant key
switch, OWD with audio-visual alarm,
VAS in Telugu & English with
intercom system with telephone
instrument in Lift car, LMR &
FCC/ground floor
Clear Car size of ......mm wide x
......mm deep x ......mm high
• LOP with SS face plate having
recess/surface push button box for all
landings with scrolling UP/DN LED
indicator having metallic push buttons
with Braille Code & luminous indicator
around button with CPI, Lift car arrival
& next travel direction audio-visual
indication at all landings
• Lift controller based on
microprocessor/ PLC with VVVF Drive
having closed loop control system,
with IBMS compatible having
necessary port, control panel duly
wired with proper size & strength
copper wire for power & control
circuit, with provision
for addition of floor/ control card &
allied accessories control panel
having enclosure of 1.5mm CRCA
sheet with powder coating with IP54
Protection class
ARD complete with necessary SMF
VRLA batteries

232
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

• Fireman controller having fireman


switch at fire Landing,
• CCTV surveillance system
comprises of 2nos minimum 2.0MP
FHD IP based vandal proof Dome
camera in lift car & in LMR/inside lift
shaft top aimed on Lift machinery &
controller with NVR kept in LMR/FCC
with HDR data backup for 60 days
with 18" FHD TV monitor, to be kept
in FCC/LMR as directed by Engineer
In Charge
• Lift Machine of Gearless PMSM of
suitable kW with Traction pulley,
OSG, electromagnetic brakes, entire
assembly mounted on adequate size
girders duly fixed on LMR floor/ shaft
walls complete with main/diverter
traction sheaves, suspension wire
ropes/belts of adequate size &
strength
Other mechanical parts such as 'T'
section adequate size guide rails for
car & counter weight with brackets
fasteners, counter weight frame with
necessary blocks, buffers with
necessary support arrangement, MS
pit ladder etc. erected with necessary
steel work
• Minor civil work for alteration if any
and erection of door frames and
accessories, erection buffers, erection
of lift machinery
, adequate size core cuts if required &
scaffolding for erecting guide rails
fixing of girders for mounting lift
machine etc. complete as per
specification no. LFT.
• Lift shaft available having
clear size of ......mm wide x
......mm deep , ......mm Pit depth, ,
………mm Overhead
749 MAT- ELEC-13.1.5 Supply,Installation,Testing and 1Job 1891300.00
08538 Commissioning of Electric Traction
Passenger cum Stretcher/Hospital
Lift of Makes : As per list of
recommended brands.
with
• Rated capacity :- 20
Passenger/1360Kg
• Floors :- G+1 floor (2Stops/2
Landings)
• Travel :- 3 to 4.2 mtrs
• Location of Lift Machine:- MRL
• Rated speed :- 1.0mps VS
• Doors type :- COPO/TOPO Doors

233
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

with frame having clear opening of


1100/1200 mm wide x 2000 mm high
made from SS 304 grade sheet of
1.5mm, thick in hairline finish for car
and all landing doors with SS door
architraves/frames
• Lift car enclosure made from SS 304
grade sheet of 1.5mm, thick with
hairline finish with frame made from
MS girders, bracing of adequate size
with minimum safety factor of 5, with
Toe Guard Apron, with necessary
false ceiling with adequate LED lights,
blower/fan for ventilation & SS
chequered plate flooring, handrails,
mirror, emergency light etc.
• COP with SS face plate having
metallic push buttons with Braille
Code & luminous indicator around
button with FPI, scrolling UP/DN LED
indicator & with/without attendant key
switch, OWD with audio-visual alarm,
VAS in Telugu & English with
intercom system with telephone
instrument in Lift car, LMR &
FCC/ground floor
• Clear Car size of ......mm wide x
....mm deep x ......mm high
LOP with SS face plate having
recess/surface push button box for all
landings with scrolling UP/DN LED
indicator having metallic push buttons
with Braille Code & luminous indicator
around button with CPI, Lift car arrival
& next travel direction audio-visual
indication at all landings
• Lift controller based on
microprocessor/ PLC with VVVF Drive
having closed loop control system,
with IBMS compatible having
necessary port, control panel duly
wired with proper size & strength
copper wire for power & control
circuit, with provision
for addition of floor/control card &
allied accessories control panel
having enclosure of 1.5mm CRCA
sheet with powder coating with IP54
Protection class
ARD complete with necessary SMF
VRLA batteries
• Fireman controller having fireman
switch at fire Landing,
• CCTV surveillance system
comprises of 2nos minimum 2.0MP
FHD IP based vandal proof Dome
camera in lift car & in LMR/inside lift

234
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

shaft top aimed on Lift machinery &


controller with NVR kept in LMR/FCC
with HDR data backup for 60 days
with 18" FHD TV monitor, to be kept
in FCC/LMR as directed by Engineer
In Charge.
• Lift Machine of Gearless PMSM of
suitable kW with Traction pulley,
OSG, electromagnetic brakes, entire
assembly mounted on adequate size
girders duly fixed on LMR floor/ shaft
walls complete with main/diverter
traction sheaves, suspension wire
ropes/belts of adequate size &
strength.
Other mechanical parts such as 'T'
section adequate size guide rails for
car & counter weight with brackets
fasteners, counter weight frame with
necessary blocks, buffers with
necessary support arrangement, MS
pit ladder etc. erected with necessary
steel work
• Minor civil work for alteration if any
and erection of door frames and
accessories, erection buffers, erection
of lift machinery, adequate size core
cuts if required & scaffolding for
erecting guide rails fixing of girders
for mounting lift machine etc.
complete as per specification no. LFT.
• Lift shaft available having clear
size of ......mm wide x
......mm deep, ......mm Pit depth,
………mm Overhead.
750 MAT- ELEC-13.1.6 Supply,Installation,Testing and 1Job 1940200.00
08539 Commissioning of Electric Traction
Passenger Lift of Makes : As per list
of recommended brands.
with
• Rated capacity :- 22
Passenger/1496Kg
• Floors :- G+1 floor (2Stops/2
Landings)
• Travel :- 3 to 4.2 mtrs
• Location of Lift Machine:- MRL
• Rated speed :- 1.0mps VS
• Doors type :- COPO/TOPO Doors
with frame having clear opening of
1100 mm wide x 2000 mm high made
from SS 304 grade sheet of 1.5mm,
thick in hairline finish for car and all
landing doors with SS door
architraves/frames
• Lift car enclosure made from SS 304
grade sheet of 1.5mm, thick with

235
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

hairline finish with frame made from


MS girders, bracing of adequate size
with minimum safety factor of 5, with
Toe Guard Apron, with necessary
false ceiling with adequate LED lights,
blower/fan for ventilation & SS
chequered plate flooring, handrails,
mirror, emergency light etc.
COP with SS face plate having
metallic push buttons with Braille
Code & luminous indicator around
button with FPI, scrolling UP/DN LED
indicator & with/without attendant key
switch, OWD with audio-visual alarm,
VAS in Telugu & English with
intercom system with telephone
instrument in Lift car, LMR &
FCC/ground floor
• Clear Car size of ......mm wide x
......mm deep x ......mm high
• LOP with SS face plate having
recess/surface push button box for all
landings with scrolling UP/DN LED
indicator having metallic push buttons
with Braille Code & luminous indicator
around button with CPI, Lift car arrival
& next travel direction audio-visual
indication at all landings
Lift controller based on
microprocessor/ PLC with VVVF Drive
having closed loop control system,
with IBMS compatible having
necessary port, control panel duly
wired with proper size & strength
copper wire for power & control
circuit, with provision for addition of
floor/control card & allied accessories
control panel having enclosure of
1.5mm CRCA sheet with powder
coating with IP54 Protection class
• ARD complete with necessary SMF
VRLA batteries
• Fireman controller having fireman
switch at fire Landing,
Lift Machine of Gearless PMSM of
suitable kW with Traction pulley,
OSG, electromagnetic brakes, entire
assembly mounted on adequate size
girders duly fixed on LMR floor/ shaft
walls complete with main/diverter
traction sheaves, suspension wire
ropes/belts of adequate size &
strength
• Other mechanical parts such as 'T'
section adequate size guide rails for
car & counter weight with brackets
fasteners, counter weight frame with

236
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

necessary blocks, buffers with


necessary

support arrangement, MS pit ladder


etc. erected with necessary steel work
Minor civil work for alteration if any
and erection of door frames and
accessories, erection buffers, erection
of lift machinery, adequate size core
cuts if required & scaffolding for
erecting guide rails fixing of girders
for mounting lift machine etc.
complete as
per specification no. LFT.
• Lift shaft available having clear
size of ......mm wide x
......mm deep, ......mm Pit depth,
………mm Overhead.
751 MAT- ELEC-13.1.7 Supply,Installation,Testing and 1Job 2069800.00
08540 Commissioning of Electric Traction
Passenger cum Stretcher/Hospital
Lift of Makes : As per list of
recommended brands.
with
• Rated capacity :- 26
Passenger/1768Kg
• Floors :- G+1 floor (2Stops/2
Landings)
• Travel :- 3 to 4.2 mtrs
• Location of Lift Machine:- MR
• Rated speed :- 1.0mps VS
• Doors type :- COPO/TOPO Doors
with frame having clear opening of
1100/1200 mm wide x 2000 mm high
made from SS 304 grade sheet of
1.5mm, thick in hairline finish for car
and all landing doors with SS door
architraves/frames
• Lift car enclosure made from SS 304
grade sheet of 1.5mm, thick with
hairline finish with frame made from
MS girders, bracing of adequate size
with minimum safety factor of 5, with
Toe Guard Apron, with necessary
false ceiling with adequate LED lights,
blower/fan for ventilation & SS
chequered plate flooring, handrails,
mirror, emergency light etc.
COP with SS face plate having
metallic push buttons with Braille
Code & luminous indicator around
button with FPI, scrolling UP/DN LED
indicator & with/without attendant key
switch, OWD with audio-visual alarm,
VAS in Telugu & English with
intercom system with telephone
instrument in Lift car, LMR

237
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

& FCC/ground floor


• Clear Car size of ......mm wide x
......mm deep x ......mm high
•LOP with SS face plate having
recess/surface push button box for all
landings with scrolling UP/DN LED
indicator having metallic push buttons
with Braille Code & luminous indicator
around button with CPI, Lift car arrival
& next travel direction audio-visual
indication at all landings
Lift controller based on
microprocessor/ PLC with VVVF Drive
having closed loop control system,
with IBMS compatible having
necessary port, control panel duly
wired with proper size & strength
copper wire for power & control
circuit, with provision for addition of
floor/control card & allied accessories
control panel having enclosure of
1.5mm CRCA sheet with powder
coating with IP54 Protection class
• ARD complete with necessary
SMF VRLA batteries
• Fireman controller having
fireman switch at fire Landing,
• CCTV surveillance system
comprises of 2nos minimum 2.0MP
FHD IP based vandal proof Dome
camera in lift car & in LMR/inside lift
shaft top aimed on Lift machinery &
controller with NVR kept in LMR/FCC
with HDR data backup for 60 days
with 18" FHD TV monitor, to be kept
in FCC/LMR as directed by Engineer
In Charge.
Lift Machine of Gearless PMSM of
suitable kW with Traction pulley,
OSG, electromagnetic brakes, entire
assembly mounted on adequate size
girders duly fixed on LMR floor/ shaft
walls complete
with main/diverter traction sheaves,
suspension wire ropes/belts
of adequate size & strength
• Other mechanical parts such as 'T'
section adequate size guide rails for
car & counter weight with brackets
fasteners, counter weight frame with
necessary blocks, buffers with
necessary support arrangement, MS
pit ladder etc. erected with necessary
steel work
• Minor civil work for alteration if any
and erection of door frames and

238
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

accessories, erection buffers, erection


of lift machinery, adequate size core
cuts if required & scaffolding for
erecting guide rails fixing of girders
for mounting lift machine etc.
complete as per specification no. LFT.
• Lift shaft available having
clear size of ......mm wide x......mm
deep, ......mm Pit depth, ………mm
Overhead.
752 MAT- ELEC-13.1.8 Supply,Installation,Testing and 1Job 2512600.00
08541 Commissioning of Electric Traction
Goods Lift of Makes : As per list of
recommended brands.
with
• Rated capacity :- 3000Kg
Goods/44 Passengers
• Floors :- G+1 floor (2Stops/2
Landings)
• Travel :- 3 to 4.2 mtrs
• Location of Lift Machine:- MR
• Rated speed :- 0.6 to 1.0mps
VS
• Doors type :- COPO/TOPO Doors
with frame having clear opening of
1700 mm wide x 2000 mm high made
from SS 304 grade sheet of 1.5mm,
thick in hairline finish for car and all
landing doors with SS door
architraves/frames
• Lift car enclosure made from SS 304
grade sheet of 1.5mm, thick with
hairline finish with frame made from
MS girders, bracing of adequate size
with minimum safety factor of 5, with
Toe Guard Apron, with necessary
false ceiling with adequate LED lights,
blower/fan for ventilation & SS
chequered plate flooring, handrails,
mirror, emergency light etc.
• COP with SS face plate having
metallic push buttons with Braille
Code & luminous indicator around
button with FPI, scrolling
UP/DN LED indicator & with/without
attendant key switch, OWD with
audio-visual alarm, VAS in Telugu
&English with intercom system with
telephone instrument in Lift car, LMR
& FCC/ground floor
• Clear Car size of ......mm wide x
......mm deep x ......mm high
LOP with SS face plate having
recess/surface push button box for all
landings with scrolling UP/DN LED
indicator having metallic push buttons
with Braille Code & luminous indicator

239
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

around button with

CPI, Lift car arrival & next travel


direction audio-visual indication at all
landings
• Lift controller based on
microprocessor/ PLC with VVVF Drive
having closed loop control system,
with IBMS compatible having
necessary port, control panel duly
wired with proper size & strength
copper wire for power & control
circuit, with provision for addition of
floor/control card & allied accessories
control panel having enclosure of
1.5mm CRCA sheet with powder
coating with IP54 Protection class
• ARD complete with necessary
SMF VRLA batteries
• Fireman controller having
fireman switch at fire Landing,
• Lift Machine of Gearless PMSM of
suitable kW with Traction pulley,
OSG, electromagnetic brakes, entire
assembly mounted on adequate size
girders duly fixed on LMR floor/ shaft
walls complete with main/diverter
traction sheaves, suspension wire
ropes/belts of adequate size &
strength
Other mechanical parts such as 'T'
section adequate size guide rails for
car & counter weight with brackets
fasteners, counter
weight frame with necessary
blocks, buffers with necessary
support arrangement, MS pit ladder
etc. erected with necessary steel work
• Minor civil work for alteration if any
and erection of door frames and
accessories, erection buffers, erection
of lift machinery, adequate size core
cuts if required & scaffolding for
erecting guide
rails fixing of girders for mounting
lift machine etc. complete as per
specification no. LFT.• Lift shaft
available having clear size of
......mm wide x......mm deep, ......mm
Pit depth, ………mm Overhead.
753 MAT- ELEC-13.1.9 Supply,Installation,Testing and 1Job 2782500.00
08542 Commissioning of Electric Traction
Goods Lift of Makes : As per list of
recommended brands.
with

240
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

• Rated capacity :- 4000Kg


Goods /59 Passengers
• Floors :- G+1 floor (2Stops/2
Landings)
• Travel :- 3 to 4.2 mtrs
• Location of Lift Machine:- MR
• Rated speed :- 0.6 to 1.0mps
VS
• Doors type :- COPO/TOPO Doors
with frame having clear opening of
2100 mm wide x 2000 mm high made
from SS 304 grade sheet of 1.5mm,
thick in hairline finish for car and all
landing doors with SS door
architraves/frames
• Lift car enclosure made from SS 304
grade sheet of 1.5mm, thick with
hairline finish with frame made from
MS girders, bracing of adequate size
with minimum safety factor of 5, with
Toe Guard Apron, with necessary
false ceiling with adequate LED lights,
blower/fan for ventilation & SS
chequered plate flooring, handrails,
mirror, emergency light etc.
• COP with SS face plate having
metallic push buttons with Braille
Code & luminous indicator around
button with FPI, scrolling UP/DN LED
indicator & with/without attendant key
switch, OWD with audio-visual alarm,
VAS in Telugu & English with
intercom system with telephone
instrument in Lift car, LMR &
FCC/ground floor
Clear Car size of ......mm wide x
......mm deep x ......mm high
• LOP with SS face plate having
recess/surface push button box for all
landings with scrolling UP/DN LED
indicator having metallic push buttons
with Braille Code & luminous indicator
around button
with CPI, Lift car arrival & next travel
direction audio-visual
indication at all landings
• Lift controller based on
microprocessor/ PLC with VVVF Drive
having closed loop control system,
with IBMS compatible having
necessary port, control panel duly
wired with proper size & strength
copper wire for power & control
circuit, with provision for addition of
floor/control card & allied accessories
control panel having enclosure of
1.5mm CRCA sheet with powder

241
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

coating with IP54 Protection class


ARD complete with necessary SMF
VRLA batteries
• Fireman controller having
fireman switch at fire Landing,
• Lift Machine of Gearless PMSM of
suitable kW with Traction pulley,
OSG, electromagnetic brakes, entire
assembly mounted on adequate size
girders duly fixed on LMR floor/ shaft
walls complete with main/diverter
traction sheaves, suspension wire
ropes/belts of adequate size &
strength.
Other mechanical parts such as 'T'
section adequate size guide rails for
car & counter weight with brackets
fasteners, counter weight frame with
necessary blocks, buffers with
necessary support arrangement, MS
pit ladder etc. erected with necessary
steel work
• Minor civil work for alteration if any
and erection of door frames
and accessories, erection buffers,
erection of lift machinery, adequate
size core cuts if required & scaffolding
for erecting guide
rails fixing of girders for mounting
lift machine etc. complete as per
specification no. LFT.
• Lift shaft available having
clear size of ......mm wide x......mm
deep, ......mm Pit depth, ………mm
Overhead.
NOTE: 1. The above rates are applicable
only for the makes:
KONE/OTIS/SCHINDLER/MITSUBIS
HI/JOHNSON.
2. If the local reputed brands
prefered by the Departments or
Corporations, the makes Suryodaya
Elevators/ESCO Lifts/Sunrise Lifts/ or
any other make approved by the
competent authority subject to the
condition that the Specifications
remains unchanged can be adopted
in the estimate by reducing the price
@15% less than the above rates.
Add On

A For Lift travelling up to six floors or at


a speed of 1.0 mps, add as below,

242
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
754 MAT- 1 For Lift having 700mm wide x 1Floor 130650.00
08543 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
755 MAT- 2 For Lift having 800mm wide x 1Floor 134600.00
08544 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,traveling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
756 MAT- 3 For Lift having 900mm wide x 1Floor 139300.00
08545 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
757 MAT- 4 For Lift having 1000mm wide x 1Floor 143500.00
08546 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safefunctioning of lift
installation complete
758 MAT- 5 For Lift having 1100mm wide x 1Floor 147800.00
08547 2000mm high clear entrance in
1.5mm thick SS 304 grade landing

243
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

door [Two panel], this includes all


necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts,
&OSG rope landingdoors with all
accessories etc. necessary for the
normal safefunctioning of lift
installation complete
759 MAT- 6 For Lift having 1200mm wide x 1Floor 152900.00
08548 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
760 MAT- 7 For Lift having 1300mm wide x 1Floor 157600.00
08549 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two/four panel], this includes
all necessary accessories like LOP's
with UP/DN buttons- arrows-
indicators, extension of guide rails,
shaft wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landingdoors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
761 MAT- 8 For Lift having 1400mm wide x 1Floor 162400.00
08550 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two/four panel], this includes
all necessary accessories like LOP's
with UP/DN buttons-arrows-indicators,
extension of guide rails, shaft wiring
with trunking,travelling cables, main
hoisting ropes/belts, & OSG rope
landing doors with all accessories
etc. necessary for the normal
safe functioning of lift installation
complete
762 MAT- 9 For Lift having 1500mm wide x 1Floor 170600.00
08551 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Four panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-

244
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

indicators, extension of guide rails,


shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
763 MAT- 10 For Lift having 1700mm wide x 1Floor 178900.00
08552 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Four panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
764 MAT- 11 For Lift having 1800mm wide x 1Floor 188000.00
08553 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Four panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
765 MAT- 12 For Lift having 2100mm wide x 1Floor 204800.00
08554 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Six panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
766 MAT- 13 For Lift having 2200mm wide x 1Floor 211900.00
08555 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Six panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &

245
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

OSG rope landing doors with all


accessories etc. necessary for the
normal safe functioning of lift
installation complete
A1 For Lift travelling above six floors & up
to fifteen floors or at a speed of 1.5
mps, add as below,
767 MAT- 1 For Lift having 700mm wide x 1Floor 136500.00
08556 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
768 MAT- 2 For Lift having 800mm wide x 1Floor 140700.00
08557 2000mm high clear entrance in1.5mm
thick SS 304 grade landing door [Two
panel], this includes all necessary
accessories like LOP's with UP/DN
buttons-arrows- indicators, extension
of guide rails, shaft wiring with
trunking, travelling cables, main
hoisting ropes/belts, & OSG rope
landing doors with all accessories
etc. necessary for the normal
safe functioning of lift installation
complete
769 MAT- 3 For Lift having 900mm wide x 1Floor 145600.00
08558 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
770 MAT- 4 For Lift having 1000mm wide x 1Floor 149900.00
08559 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &

246
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

OSG rope landing doors with all


accessories etc. necessary for the
normal safe functioning of lift
installation complete
771 MAT- 5 For Lift having 1100mm wide x 1Floor 154400.00
08560 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
772 MAT- 6 For Lift having 1200mm wide x 1Floor 159800.00
08561 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
773 MAT- 7 For Lift having 1300mm wide x 1Floor 164600.00
08562 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two/four panel], this includes
all necessary accessories like LOP's
with UP/DN buttons- arrows-
indicators, extension of guide rails,
shaft wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
774 MAT- 8 For Lift having 1400mm wide x 1Floor 169600.00
08563 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two/four panel], this includes
all necessary accessories like LOP's
with UP/DN buttons-arrows-indicators,
extension of guide rails, shaft wiring
with trunking, travelling cables, main
hoisting ropes/belts, & OSG rope
landing doors with all accessories
etc. necessary for the normal
safe functioning of lift installation

247
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

complete

775 MAT- 9 For Lift having 1500mm wide x 1Floor 178100.00


08564 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Four panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
776 MAT- 10 For Lift having 1700mm wide x 1Floor 186900.00
08565 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Four panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
777 MAT- 11 For Lift having 1800mm wide x 1Floor 196300.00
08566 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Four panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
778 MAT- 12 For Lift having 2100mm wide x 1Floor 213900.00
08567 2000mm high clear entrance 1.5mm
thick SS 304 grade landing door [Six
panel], this includes all necessary
accessories like LOP's with UP/DN
buttons-arrows- indicators, extension
of guide rails, shaft wiring with
trunking, travelling cables, main
hoisting ropes/belts, & OSG rope
landing doors with all accessories
etc. necessary for the normal
safe functioning of lift installation
complete

248
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
779 MAT- 13 For Lift having 2200mm wide x 1Floor 221400.00
08568 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Six panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope landing doors with all
accessories etc. necessary for the
normal safe functioning of lift
installation complete
A2 For Lift travelling above fifteen floors
& up to twenty floors or at a speed of
1.75 mps, add as below,
780 MAT- 1 For Lift having 800mm wide x 1Floor 144800.00
08569 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope, landing doors with all
accessories etc. complete for the safe
functioning of lift installation.
781 MAT- 2 For Lift having 900mm wide x 1Floor 149900.00
08570 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope, landingdoors with all
accessories etc. complete for the safe
functioning of lift installation.
782 MAT- 3 For Lift having 1000mm wide x 1Floor 154300.00
08571 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope, landing doors with all
accessories etc. complete for the safe
functioning of lift installation.
783 MAT- 4 For Lift having 1100mm wide x 1Floor 159000.00
08572 2000mm high clear entrance in
1.5mm thick SS 304 grade landing

249
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

door [Two panel], this includes all


necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts,
&OSG rope, landing doors with all
accessories etc. complete for the safe
functioning of lift installation.
784 MAT- 5 For Lift having 1200mm wide x 1Floor 164500.00
08573 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope, landing doors with all
accessories etc. complete for the safe
functioning of lift installation.
785 MAT- 6 For Lift having 1300mm wide x 1Floor 169500.00
08574 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two/four panel], this includes
all necessary accessories like LOP's
with UP/DN buttons-arrows-indicators,
extension of guide rails, shaft wiring
with trunking,travelling cables, main
hoisting ropes/belts, & OSG rope,
landing doors with all accessories etc.
complete for the safe functioning of lift
installation.
786 MAT- 7 For Lift having 1400mm wide x 1Floor 174600.00
08575 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Two/four panel], this includes
all necessary accessories like LOP's
with UP/DN buttons-arrows-indicators,
extension of guide rails, shaft wiring
with trunking,travelling cables, main
hoisting ropes/belts, & OSG rope,
landing doors with all accessories etc.
complete for the safe functioning of lift
installation.
787 MAT- 8 For Lift having 1500mm wide x 1Floor 183300.00
08576 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Four panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope, landing doors with all

250
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

accessories etc. complete for the safe


functioning of lift installation.

788 MAT- 9 For Lift having 1700mm wide x 1Floor 192500.00


08577 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Four panel], this includes all
necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking,travelling
cables, main hoisting ropes/belts, &
OSG rope, landing doors with all
accessories etc. complete for the safe
functioning of lift installation.
789 MAT- 10 For Lift having 1800mm wide x 1Floor 163700.00
08578 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Four panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope, landing doors with all
accessories etc. complete for the safe
functioning of lift installation.
790 MAT- 11 For Lift having 2100mm wide x 1Floor 220400.00
08579 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Six panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope, landing doors with all
accessories etc. complete for the safe
functioning of lift installation.
791 MAT- 12 For Lift having 2200mm wide x 1Floor 227800.00
08580 2000mm high clear entrance in
1.5mm thick SS 304 grade landing
door [Six panel], this includes all
necessary accessories like LOP's with
UP/DN buttons-arrows- indicators,
extension of guide rails, shaft
wiring 1.5mm thick SS 304 grade
landing door [Six panel], this includes
all necessary accessories like LOP's
with UP/DN buttons-arrows-
indicators, extension of guide rails,
shaft wiring with trunking, travelling
cables, main hoisting ropes/belts, &
OSG rope, landing doors with all
accessories etc. complete for the safe
functioning of lift installation.

251
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

B If there is additional automatic car


door, add as below.

792 MAT- 1 For Lift car having 700mm wide x 1Set 108200.00
08581 2000mm high clear entrance having
1.5mm thick SS 304 grade sheet
car door [Two panel] complete with
required accessories like door
operator mechanism with drive,
required aluminium sill, infrared
curtain & necessary wiring with
interlocking arrangement etc.
complete.
793 MAT- 2 For Lift car having 800mm wide x 1Set 111500.00
08582 2000mm high clear entrance having
1.5mm thick SS 304 grade sheet
car door [Two panel] complete with
required accessories like door
operator mechanism with drive,
required Aluminium sill, infrared
curtain & necessary wiring with
interlocking arrangement etc.
complete.
794 MAT- 3 For Lift car having 900mm wide x 1Set 115400.00
08583 2000mm high clear entrance having
1.5mm thick SS 304 grade sheet
car door [Two panel] complete with
required accessories like door
operator mechanism with drive,
required aluminium sill, infrared
curtain & necessary wiring with
interlocking arrangement etc.
complete.
795 MAT- 4 For Lift car having 1000mm wide x 1Set 119200.00
08584 2000mm high clear entrance having
1.5mm thick SS 304 grade sheet
car door [Two panel]complete with
required accessories like door
operator mechanism with drive,
required aluminium sill, infrared
curtain & necessary wiring with
interlocking arrangement etc.
complete.
796 MAT- 5 For Lift car having 1100mm wide x 1Set 122800.00
08585 2000mm high clear entrance having
1.5mm thick SS 304 grade sheet
car door [Two panel]complete with
required accessories like door
operator mechanism with drive,
required aluminium sill, infrared
curtain & necessary wiring with
interlocking arrangement etc.
complete

252
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
797 MAT- 6 For Lift car having 1200mm wide x 1Set 127200.00
08586 2000mm high clear entrance having
1.5mm thick SS 304 grade sheet
car door [Two panel]complete with
required accessories like door
operator mechanism with drive,
required aluminium sill, infrared
curtain & necessary wiring with
interlocking arrangement etc.
complete.
798 MAT- 7 For Lift car having 1300mm wide x 1Set 131300.00
08587 2000mm high clear entrance having
1.5mm thick SS 304 grade sheet car
door [Two/four panel] complete with
required accessories like door
operator mechanism with drive,
required aluminium sill, infrared
curtain & necessary wiring with
interlocking arrangement etc.
complete.
799 MAT- 8 For Lift car having 1400mm wide x 1Set 135200.00
08588 2000mm high clear entrance having
1.5mm thick SS 304 grade sheet car
door [Two/four panel]complete with
required accessories like door
operator mechanism with drive,
required aluminium sill, infrared
curtain & necessary wiring with
interlocking arrangement etc.
complete.
800 MAT- 9 For Lift car having 1500mm wide x 1Set 141900.00
08589 2000mm high clear entrance
having 1.5mm thick SS 304 grade
sheet car door [four panel] complete
with required accessories like door
operator mechanism with
drive,required aluminium sill,
infrared curtain & necessary wiring
with interlocking arrangement etc.
complete.
801 MAT- 10 For Lift car having 1700mm wide x 1Set 149800.00
08590 2000mm high clear entrance
having 1.5mm thick SS 304 grade
sheet car door [four panel] complete
with required accessories like door
operator mechanism with
drive,required aluminium sill,
infrared curtain & necessary wiring
with interlocking arrangement etc.
complete.
802 MAT- 11 For Lift car having 1800mm wide x 1Set 157200.00
08591 2000mm high clear entrance
having 1.5mm thick SS 304 grade
sheet car door [four panel] complete
with required accessories like door

253
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

operator mechanism with


drive,required aluminium sill,
infrared curtain & necessary wiring
with interlocking arrangement etc.
complete.
803 MAT- 12 For Lift car having 2100mm wide x 1Set 171800.00
08592 2000mm high clear entrance
having 1.5mm thick SS 304 grade
sheet car door [six panel] complete
with required accessories like door
operator mechanism with
drive,required aluminium sill,
infrared curtain & necessary wiring
with interlocking arrangement etc.
complete.
804 MAT- 13 For Lift car having 2200mm wide x 1Set 178400.00
08593 2000mm high clear entrance
having 1.5mm thick SS 304 grade
sheet car door [six panel] complete
required aluminium sill, infrared
curtain & necessary wiring
interlocking arrangement etc.
complete.
C For Full Collective control system, add
as below.

805 MAT- 1 For Lift travelling above First floor & 1No 26900.00
08594 up to Sixth floor

806 MAT- 2 For Lift travelling above Sixth floor & 1No 61600.00
08595 up to Fifteenth floor

807 MAT- 3 For Lift travelling above Fifteenth floor 1No 80800.00
08596 & up to Twentieth floor

808 MAT- D For additional 2MP Camera along with 1No 13300.00
08597 necessary accessories at Home
Landing, add as given.
E For Group control system of number
of lifts, add as below.

809 MAT- 1 For Duplex Lift control system 1Job 34200.00


08598

810 MAT- 2 For Triplex Lift control system 1Job 51100.00


08599

811 MAT- 3 For Quadruplex Lift control system 1Job 68900.00


08600

254
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
812 MAT- F 1No 2700.00
08601 For vision panel having Size 100mm
wide x 200mm high covered
with fire rated laminated glass, having
punched Jali as a part of the door
panel SS sheet itself.
G The above rates are for landing & car
door height of 2000mm and Lift car
ceiling height of 2250mm.
If the requirements for landing & car
doors height above
2000mm & Lift car height above
2250mm, add overall Rs. ...... per
100mm rise per Lift per landing.
a For Lift car enclosure & car door per
100mm Step rise

814 MAT- 1 for Lift car door, having clear entrance 1 per 44300.00
08602 of 700/800/900mm wide Landing

815 MAT- 2 for Lift car door, having clear entrance 1 per 60700.00
08603 1000/1100/1200/1300mm Landing
wide
816 MAT- 3 for Lift car door, having clear entrance 1 per 106400.00
08604 1400/1500/1700mm wide Landing

817 MAT- 4 for Lift car door, having clear entrance 1 per 180800.00
08605 1800/2100/2200mm wide Landing

b For Lift Landings per 100mm Step rise

818 MAT- 1 for Lift Landing door having clear 1 per 11100.00
08606 entrance of 700/800/900mm Landing
wide
819 MAT- 2 for Lift Landing door, having clear 1 per 15100.00
08607 entrance of 1000/1100/1200/1300mm Landing
wide
820 MAT- 3 for Lift Landing door, having clear 1 per 23900.00
08608 entrance of 1400/1500/1700mm Landing
wide
821 MAT- 4 for Lift Landing door, having clear 1 per 35800.00
08609 entrance of 1800/2100/2200mm wide Landing

Notes:

1 General: - Job includes entire


procedure of obtaining all
necessary erection permissions &
"License to Work the Lift" from
Electrical Inspector(Lifts) with
submission to the Engineer In Charge.

255
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

2 Warrantee: - Job covers two years


onsite warrantee for all the
Lift parts with FCAMC as per the
maintenance schedule.
Note 1 and 2 above shall be included
in item description.

3 If the lift shaft is greater than the


required size of the lift as mentioned
in relevant Indian Standard [with
Amendments up to date], the
provision of extra steel required for
erecting supports of guide rails shall
be made by the department as a
separate item
4 The Electric power supply of 415
volts, 3 phase 4 wire,50Hz shall be
made available up to Lift controller,
and as per the provisions laid down
in relevant The Electricity Safety
Regulations
2010[with Amendments up to date],
Indian Standard, relevant Rules, the
separate cables for lighting and power
& shall be erected through lift shaft
only with 2nos distinct earth
connections from lift machine &
controller
5 The technical specification of Lift
duty motor, control panel, brakes,
guide rails, and guide shoes, lift car
frame, car, counter weight and
suspension, lift safety gear and
governor, buffer, lift doors, locking
device and contacts, lift wire rope of
lifts shall be as per actual requirement
of the job.
6 For nonstandard lift shafts the Lift
capacity shall be selected so that all
the safety clearances to be
maintained as per the provisions
laid down in relevant Indian
Standard, & relevant Rules and work
shall be carried out accordingly
7 For building having height of 15 mtr or
more, lift shall meet the requirement
of fireman lift as per the statutory
requirements laid in relevant Indian
Standard
8 While framing estimates of lifts for
handicapped persons/
Hospital/Goods Lifts, the relevant
Indian standard shall be referred for
dimensions.

256
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

9 The sizes in mm for Lift car, entrance,


available lift Shaft etc. with travel
shall be mentioned in the Detailed
Estimate
10 The above rates are for mostly
installed Electric Traction Lifts, for Lift
requirements with different purposes/
specifications, the items should be got
approved from the competent
authority
11 The Traffic Analysis [TA] shall be
done as per the provisions laid down
in relevant Indian standards for
finalizing the capacity and number of
Lifts in different types of buildings.
13.2: LIFT
REPAIR/MODERNIZATION
LIFT MACHINE
822 MAT- ELEC-13.2.1 Overhauling of Gearbox by opening 1Job 6000.00
08610 the gear box, cleaning the oil path
with oil adjusting the Thrust bearing, &
bush with packings etc. and refilling
with the fresh oil of requisite viscosity
and sufficient quantity, complete
with re-erection as original with
necessary alignment & testing.
823 MAT- ELEC-13.2.2 Providing dismantling the existing 1Job 15000.00
08611 worn-out/damaged Thrust bearing &
bush with allied accessories
complete supplying &installing new
Thrust bearing & Bush with allied
accessories like packings etc. and
refilling with the fresh gear oil of
requisite viscosity and sufficient
quantity, complete suitable up to 10
passenger lift car with re-erection as
original with necessary alignment &
testing
824 MAT- ELEC-13.2.3 Providing dismantling the existing lift 1Job 3000.00
08612 duty electric motor from
lift gearbox coupling to carryout
necessary repairs and re-erection the
same as original with necessary
alignment & testing complete after
repairing
825 MAT- ELEC-13.2.4 Providing rewinding of the 1Job 4500.00
08613 electromagnetic type brake coil
suitable to operate on 110V DC
supply by superior quality enamelled
copper wire of require size complete
with testing

257
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
826 MAT- ELEC-13.2.5 Providing and fixing new set brake 1Job 2500.00
08614 liner of good quality complete with
alignment & testing with removal of
old worn-out brake liners
827 MAT- ELEC-13.2.6 Providing dismantling the existing 1Job 14500.00
08615 main driving sheave complete by
hanging the lift car and providing and
fixing a new main driving sheave
made from superior quality cast
iron completely finished having
diameter up to 600mm suitable up to
4nos rope grooves the size for the
same will be specified in the estimate
828 MAT- ELEC-13.2.7 Providing dismantling the existing 1Job 18500.00
08616 main driving sheave complete by
hanging the lift car and providing and
fixing a new main driving sheave
made from superior quality cast iron
completely finished having diameter
601 to 800mm suitable up to 4nos
rope grooves .
829 MAT- ELEC-13.2.8 Providing dismantling the existing 1Job 10400.00
08617 diverter sheave complete by
hanging the lift car and providing and
fixing a new diverter sheave made
from superior quality cast iron
completely finished having diameter
up to 250mm suitable up to 4nos rope
grooves.
830 MAT- ELEC-13.2.9 Providing dismantling the existing 1Job 11800.00
08618 diverter sheave complete by
hanging the lift car and providing and
fixing a new diverter sheave made
from superior quality cast iron
completely finished having diameter
251 to 500mm suitable up to 4nos
rope grooves.
831 MAT- ELEC-13.2.10 Providing dismantling the existing 1Job 10200.00
08619 OSG pulley set (top & bottom)
complete and providing and fixing
overspeed governor pulley set ( top&
bottom) made from superior quality
cast iron completely finished suitable
for Lift car rated speed.
832 MAT- ELEC-13.2.11 Providing dismantling the existing 1Job 400.00
08620 OSG rubber roller
complete,providing and fixing new
nylon roller of superior quality.
LIFT CAR

833 MAT- ELEC-13.2.12 Providing dismantling the existing lift 1Job 2900.00
08621 car/counter weight guide shoe liner
and providing and fixing new superior
quality non-metallic car/counter weight

258
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

guide shoe Liner complete with re-


erection,alignment & adjustment
complete with lubrication
834 MAT- ELEC-13.2.13 Providing dismantling the existing 1Job 4600.00
08622 unserviceable retiring cam (Door)by
supplying & erecting new one of
superior quality with necessary spare
complete with re-erection and testing
etc. with copper wound magnetic coil
of 110V DC supply.
835 MAT- ELEC-13.2.14 Providing dismantling the existing 1Kg 500.00
08623 deteriorated lift car flooring/floor tiles
by supplying & erecting SS
chequered plate of required
thickness and of superior quality with
necessary material
836 MAT- ELEC-13.2.15 Providing dismantling the existing 1Job 152100.00
08624 deteriorated lift car enclosure by
supplying & erecting new enclosure
made from 1.5mm thick stainless steel
sheet SS304 grade of superior
quality with necessary material
complete with handrail, mirror,
required thickness stainless steel
chequered plate flooring and min.
2.5mm thick GI sheet car top
&stainless steel 304grade 1.2mm
thick false ceiling & required LED
light fitting & cabin fan/blower,
emergency light with necessary grill
along with required accessories
suitable for 4 to 8 passenger lift car
837 MAT- ELEC-13.2.16 Providing dismantling the existing 1Job 183200.00
08625 deteriorated lift car enclosure by
supplying & erecting new enclosure
made from 1.5mm thick stainless steel
sheet SS304 grade of superior
quality with necessary material
complete with handrail, mirror,
required thickness stainless steel
chequered plate flooring and min.
2.5mm thick GI sheet car top &
stainless steel 304grade 1.2mm thick
false ceiling & required LED light
fitting & cabin fan/blower, emergency
light with necessary grill along with
required accessories suitable for 10 to
13 passenger lift
838 MAT- ELEC-13.2.17 Providing dismantling the existing 1Job 213500.00
08626 deteriorated lift car enclosure by
supplying & erecting new enclosure
made from 1.5mm thick stainless steel
sheet SS304 grade of superior
quality with necessary material
complete with handrail, mirror,

259
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

required thickness stainless steel


chequered plate flooring and min.
2.5mm thick GI sheet car top
&stainless steel 304grade 1.2mm
thick false ceiling & required LED
light fitting & cabin fan/blower,
emergency light with necessary grill
along with required accessories
suitable for 14 to 16 passenger lift car
839 MAT- ELEC-13.2.18 Providing dismantling the existing 1Job 247500.00
08627 deteriorated lift car enclosure by
supplying & erecting new enclosure
made from 1.5mm thick stainless steel
sheet SS304 grade of superior
quality with necessary material
complete with handrail, mirror,
required thickness stainless steel
chequered plate flooring and min.
2.5mm thick GI sheet car top
&stainless steel 304grade 1.2mm
thick false ceiling & required LED
light fitting & cabin fan/blower,
emergency light with necessary grill
along with required accessories
suitable for 18 to 23 Passenger Lift
Car
840 MAT- ELEC-13.2.19 Providing dismantling the existing 1Job 315900.00
08628 deteriorated Lift car enclosure by
supplying & erecting new enclosure
made from 1.5mm thick stainless steel
sheet SS304 grade of superior
quality with necessary material
complete with handrail, mirror,
required thickness stainless steel
chequered plate flooring and min.
2.5mm thick GI sheet car top
&stainless steel 304grade 1.2mm
thick false ceiling & required LED
light fitting & cabin fan/blower,
emergency light with necessary grill
along with required accessories
suitable for 26 to 36 Passenger Lift
Car
841 MAT- ELEC-13.2.20 Supplying erecting & testing & 1No 49700.00
08629 commissioning minimum 2000mm
high Infra-Red/IR curtain with
minimum 80beams, suitable to
attach automatic Lift car door
complete with electronic driver
suitable to work on 230V AC
supply with required wiring &
accessories complete connected to
the lift controller safety circuit.
including dismantling of existing
accessories as applicable

260
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
842 MAT- ELEC-13.2.21 Supplying & erecting laminated 1Sqft 500.00
08630 type with minimum 6mm thick
mirror confirming to relevant standard
in the lift car complete pasting with
necessary adhesives if required and
fixing with SS frame &accessories
complete, this job includes
dismantling of existing accessories
as applicable
LIFT SHAFT

843 MAT- ELEC-13.2.22 Providing Emergency Stop Switch 1No 700.00


08631 as per IS [push to stop&pull/rotate
clockwise to open] erected on GI box
in pit/LMR /car top for maintenance
work complete with necessary wires
844 MAT- ELEC-13.2.23 Supplying & erecting over travel 1No 2000.00
08632 final/Terminal limit switchcomplete
with nylon roller for up & down
direction alongwithcams etc as
required.
845 MAT- ELEC-13.2.24 Providing and fixing new magnetic 1No 1000.00
08633 reed switch with M.S. Flag for levelling
the lift. Providing and fixing necessary
magnet for the floor position indicator,
providing and fixing electronics card
with digital indicator, complete with re-
erection including dismantling of
existing accessories as applicable
846 MAT- ELEC-13.2.25 Supplying & erecting lift car door 1No 1000.00
08634 lock with electrical contact[spring
loaded NO/NC of 5A/250V rating]
complete unit withBakelite roller
attached to bracket on car top with
M.S. "T" bracket attached to car gate
complete with Testing including
dismantling of existing accessories as
applicable
847 MAT- ELEC-13.2.26 Supplying & erecting main suspension 1Mt 200.00
08635 wire rope of 13mm dia.having 8/19
construction as per IS complete with
termination in provided eye bolts
including dismantling of existing
accessories as applicable
848 MAT- ELEC-13.2.27 Supplying & erecting main suspension 1Mt 200.00
08636 wire rope of 10mm dia. having 8/19
construction as per IS complete
with termination in provided eye bolts
including dismantling of existing
accessories as applicable
849 MAT- ELEC-13.2.28 Supplying & erecting main 1Mt 150.00
08637 suspension wire rope of 8mm
dia.having 8/19 construction as per

261
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

IS complete with termination in


provided eye bolts including
dismantling of existing accessories as
applicable
850 MAT- ELEC-13.2.29 Supplying & erecting wire rope of 1Mt 100.00
08638 3/4/6mm dia. having 6/19
construction as per IS complete with
termination in provided eye bolts
including dismantling of existing
accessories as applicable
851 MAT- ELEC-13.2.30 Supplying & erecting GI eye bolt 1No 1500.00
08639 suitable for tie up of min. 13mm dia.
lift wire ropes with 4nos bull dog clips
8/19 construction as per IS Complete
with termination in provided eye
bolts including dismantling of existing
accessories as applicable
852 MAT- ELEC-13.2.31 Supplying & erecting GI eye bolt 1No 1200.00
08640 suitable for tie up of 8/10mm dia.lift
wire ropes with 4nos bull dog clips
8/19 construction as per IS Complete
with termination in provided eye
bolts including dismantling of existing
accessories as applicable.
CAR & LANDING DOORS:

853 MAT- ELEC-13.2.32 Repairing of M.S. collapsible 1Job 900.00


08641 landing/lift car door for broken
rivets, pickets gibes, roller bearings
complete with oiling etc. complete with
re-erection, and alignment for smooth
operation
854 MAT- ELEC-13.2.33 Supplying & erecting MS collapsible 1Job 9000.00
08642 type perforate Car/Landingdoor with
50mm high 8mm thick MS pata at top
with roller bearings & nylon gibes
complete having adequate strength as
per requirements with necessary
alignment complete with having
clear opening of 700/800mm in
width and clear height not less
than 2000mm including dismantling
of existing door as applicable
855 MAT- ELEC-13.2.34 Supplying & erecting MS collapsible 1Job 10700.00
08643 type perforate Car/Landingdoor with
50mm high 8mm thick MS pata at top
with roller bearings & nylon gibes
complete having adequate strength as
per requirements with necessary
alignment complete with having
clear opening of 1000/1200mm in
width and clear height not less
than 2000mm including dismantling

262
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

of existing door as applicable

856 MAT- ELEC-13.2.35 Supplying & erecting MS 1Job 14000.00


08644 Collapsible type imperforate
Car/Landing door with 50mm high
8mm thick MS pata at top with roller
bearings & Nylon gibes complete
having adequate strength as per
requirements with necessary
alignment complete with grassing
Note for Imperforate door the
thickness of CRCA sheet not less
than 1.mm having clear opening of
700/800mm in width and clear height
not less than 2000mm, including
dismantling of existing door as
applicable
857 MAT- ELEC-13.2.36 Supplying & erecting COPO 1Job 62700.00
08645 car/landing door panels with
frame made from 1.5mm thick SS
304grade sheet complete with
necessary coupler arrangements,
nylon bearings at hanger with header
assembly with all required
accessories with electromechanical
lock &nylon coated guide shoes
complete having adequate strength as
per requirements with necessary
alignment complete with greasing
having clear opening of 700mm in
width and clear height not less
than2000mm, including dismantling of
existing door as applicable.
858 MAT- ELEC-13.2.37 Supplying & erecting COPO 1Job 67200.00
08646 car/landing door panels with
frame made from 1.5mm thick SS
304grade sheet complete with
necessary coupler arrangements,
nylon bearings at hanger with header
assembly with all required
accessories with electromechanical
lock &nylon coated guide shoes
complete having adequate strength as
per requirements with necessary
alignment complete with greasing
having clear opening of 800mm in
width and clear height not less
than2000mm, including dismantling of
existing door as applicable
859 MAT- ELEC-13.2.38 Supplying & erecting COPO 1Job 76200.00
08647 car/landing door panels with
frame made from 1.5mm thick SS
304grade sheet complete with
necessary coupler arrangements,
nylon bearings at hanger with header

263
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

assembly with all required


accessories with electromechanical
lock&nylon coated guide shoes
complete having adequate strength as
per requirements with necessary
alignment complete with greasing
having clear opening of 900mm in
width and clear height not less
than2000mm, including dismantling of
existing door as applicable
860 MAT- ELEC-13.2.39 Supplying & erecting COPO 1Job 86800.00
08648 car/landing door panels with
frame made from 1.5mm thick SS
304grade sheet complete with
necessary coupler arrangements,
nylon bearings at hanger with header
assembly with all required
accessories with electromechanical
lock &nylon coated guide shoes
complete having adequate strength as
per requirements with necessary
alignment complete with greasing
having clear opening of 1000mm in
width and clear height not less than
2000mm, including dismantling of
existing door as applicable
861 MAT- ELEC-13.2.40 Supplying & erecting COPO 1Job 99000.00
08649 car/landing door panels with
frame made from 1.5mm thick SS
304grade sheet complete with
necessary coupler arrangements,
nylon bearings at hanger with header
assembly with all required
accessories with electromechanical
lock & nylon coated guide shoes
complete having adequate strength as
per requirements with necessary
alignment complete with greasing
having clear opening of 1200mm in
width and clear height not less than
2000mm, including dismantling of
existing door as applicable
862 MAT- ELEC-13.2.41 Providing & fixing aluminium sill with 1 1Mt 1050.00
08650 track suitable for fixing of car/ landing
door with necessary material like MS
brackets, fasteners complete with
alignment, including dismantling of
existing door as applicable
863 MAT- ELEC-13.2.42 Providing & fixing aluminium Sill with 1Mt 1400.00
08651 2 track suitable for fixing of car/
landing door with necessary material
like MS brackets, fasteners complete
with alignment, including dismantling
of existing door as applicable

264
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
864 MAT- ELEC-13.2.43 Providing & fixing landing door gate 1No 4000.00
08652 lock of superior quality with necessary
adjustable operating lever complies
with the relevant IS suitable for swing
or collapsible type landing doors
865 MAT- ELEC-13.2.44 Providing & fixing landing/Car gate 1No 150.00
08653 movable contact electricalswitch of
superior quality complies with the
relevant IS suitable for all type of
landing/car doors
866 MAT- ELEC-13.2.45 Providing & fixing LOP with single 1No 4400.00
08654 push button with metallic top& Braille
Coded suitable for UP/DN having
luminous glow indicator around button
with MS box & 3mm thick SS face
plate with screws with UP & DN
button & digital CPI (suitable for
1digits) complete with necessary
connections, including dismantling of
existing door as applicable
867 MAT- ELEC-13.2.46 Providing & fixing LOP with two push 1No 5300.00
08655 button with metallic top & Braille
coded suitable for UP/DN having
luminous glow indicator around button
with MS box & 3mm thick SS face
plate with screws with UP & DN
button & digital CPI (suitable for
2digits) complete with necessary
connections, including dismantling of
existing door as applicable
868 MAT- ELEC-13.2.47 Providing & fixing COP with push 1No 16300.00
08656 buttons having luminous glow
indicator around button suitable for
G+7 floors with push buttons with
metallic top & Braille coded suitable
for door close, door open,alarm bell,
stop, light, fan, intercom etc, FPI, with
MS box & 3mm thick SS face Plate
with UP & DN arrows & digital FPI
(suitable for 2digits) complete with
necessary connections, including
dismantling of existing COP as
applicable
869 MAT- ELEC-13.2.48 Providing & fixing push button 1No 950.00
08657 suitable with micro switch withpush
button on existing COP/LOP with
necessary connections and testing
complete including dismantling of
existing button accessories as
applicable
870 MAT- ELEC-13.2.49 Providing & fixing 40mm high fixing 1No 1200.00
08658 digital indicator module ofgives
indication of required shade with
connections and testing complete

265
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

including dismantling of existing


accessories as applicable

871 MAT- ELEC-13.2.50 Providing & fixing car door operator 1No 24000.00
08659 motor with assembly ofsuitable
capacity & speed with necessary
pulleys & required accessories
complete including dismantling of
existing accessories as applicable
872 MAT- ELEC-13.2.51 Providing & fixing hydraulic type 1No 1250.00
08660 landing door closer suitable for swing
door with necessary material
complete, including dismantling of
existing accessories as applicable
873 MAT- ELEC-13.2.52 Providing & fixing car/landing door 1 door 600.00
08661 guide shoe liner/gibescomplete with
necessary material like nylon
coating complete including
dismantling of existing accessories as
applicable
CONTROLLER

874 MAT- ELEC-13.2.53 Supplying erecting, testing & 1Job 104800.00


08662 commissioning of electronic
microprocessor/ PLC based
collective-selective lift controller with
closed loop logic suitable up to
5.5kW capacity lift duty motor
without VVVF Drive and lift car
travelling Gr+7 floors having
manual operated doors complete
erected on wall or floor made from
1.5mm thick CRCA sheet with powder
coated enclosure having IP54
protection grade, including
dismantling of existing accessories
asapplicable.
875 MAT- ELEC-13.2.54 Supplying erecting, testing & 1Job 124700.00
08663 commissioning of electronic
microprocessor/PLC based
collective-selective lift controller with
closed loop logic suitable up to
5.5kW capacity lift duty motor
without VVVF Drive & lift car
travelling Gr+7 floors having power
operated doors complete erected on
wall or floor made from 1.5mm thick
CRCA sheet with powder coated
enclosure having IP54 protection
grade. including dismantling of
existing accessories asapplicable
876 MAT- ELEC-13.2.55 Supplying erecting, testing & 1Job 60900.00
08664 commissioning of VVVF drive having
provision for closed loop logic with

266
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

necessary card, suitable to drive lift


duty electric motor up to 5.5kW
capacity to be erected in position
with necessary wiring in existing
control panel including dismantling of
existing accessories as applicable
877 MAT- ELEC-13.2.56 Supplying erecting, testing & 1Job 71350.00
08665 commissioning of VVVF drive having
provision for closed loop logic with
necessary card, suitable to drive lift
duty electric motor up to 7.5kW
capacity to be erected in position
with necessary wiring in existing
control panel including dismantling of
existing accessories as applicable
878 MAT- ELEC-13.2.57 Supplying erecting, testing & 1Job 91200.00
08666 commissioning of VVVF drive having
provision for closed loop logic with
necessary card, suitable to drive lift
duty electric motor up to 10/11kW
capacity to be erected in position
with necessary wiring in existing
control panel including dismantling of
existing accessories as applicable
879 MAT- ELEC-13.2.58 Supplying erecting, testing & 1Job 115300.00
08667 commissioning of VVVF drive having
provision for closed loop logic with
necessary card, suitable to drive lift
duty electric motor up to 15kW
capacity to be erected in position with
necessary wiring in existing control
panel including dismantling of existing
accessories as applicable
880 MAT- ELEC-13.2.59 Supplying erecting, testing & 1Job 23900.00
08668 commissioning of VVVF drive having
provision for closed loop logic suitable
to drive lift door operator motor up to
0.5/0.75kW capacity to be erected in
position with necessary wiring in
existing control panel including
dismantling of existing accessories as
applicable
881 MAT- ELEC-13.2.60 Supplying erecting, testing & 1Job 22200.00
08669 commissioning of rotary encoder
mounted on the lift motor shaft for
correct & control the positioning &
direction of the lift car & providing
closed loop feedback to the lift
controller complete with necessary
shielded data cable up to controller
with necessary connectors, this job
includes dismantling of existing
encoder if any.

267
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
882 MAT- ELEC-13.2.61 Providing & fixing 1Job 1500.00
08670 inspection/maintenance box with
cover ofsuitable size with UP/DN push
buttons (with mechanical
protection),stop button as per IS,
mechanically protected, toggle
switch for
normal/inspection/maintenance mode,
6A/250V 3Pin socket & 6A piano type
switch protected cover with bulb &
switch having IP54 grade protection
class, this job includes dismantling
of existing Inspection/maintenance
box if any.
883 MAT- ELEC-13.2.62 Providing & fixing junction box having 1Job 1100.00
08671 size of 300x300mm & height of 80mm
complete with Bakelite terminal strip
of 16A/500V rating with cover having
IP54 grade protection class includes
dismantling of existing Junction box if
any. This job includes dismantling of
existing inspection/maintenance box if
any.
884 MAT- ELEC-13.2.63 Supplying erecting, testing & 1Job 78600.00
08672 commissioning of ARD panel having
audio-visual indication in lift car
complete with necessary SMF VRLA
batteries suitable for up to 8
passenger capacity lift car including
dismantling of existing accessories as
applicable
885 MAT- ELEC-13.2.64 Supplying erecting, testing & 1Job 89100.00
08673 commissioning of ARD panel having
audio-visual indication in lift car
complete with necessary SMF VRLA
batteries suitable for 9 to 12
passenger capacity lift car. Including
dismantling of existing accessories as
applicable
886 MAT- ELEC-13.2.65 Supplying erecting, testing & 1Job 101800.00
08674 commissioning of ARD panel having
audio-visual indication in lift car
complete with necessary SMF VRLA
batteries suitable for 13 to 16
passenger capacity lift car. Including
dismantling of existing accessories as
applicable
887 MAT- ELEC-13.2.66 Supplying erecting, testing & 1Job 116000.00
08675 commissioning of ARD panel having
audio-visual indication in lift car
complete with necessary SMF VRLA
batteries suitable for 17 to 22
passenger capacity lift car. Including
dismantling of existing accessories as
applicable

268
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
888 MAT- ELEC-13.2.67 Supplying erecting, testing & 1Job 133300.00
08676 commissioning of ARD panel having
audio-visual indication in lift car
complete with necessary SMF VRLA
batteries suitable for 23 to 29
passenger capacity lift car. Including
dismantling of existing accessories as
applicable
889 MAT- ELEC-13.2.68 Providing complete lift shaft wiring in 1Job 20000.00
08677 copper wire/cable frommain controller
to car top with COP & to all landing
push button panel to all landing gate
locks to all floor levelling switch to
main motor to brake unit & final limit
switch indicator system using ISI mark
single pvc insulated flexible copper
wire having minimum1.0 sq. mm size
from controller to safety devices &
0.75Sqmm size for indication system
complete in PVC/GI trunking with
cover for lift with manually/power
operated doors travelling up to
G+1floors /2stops& 2landings for
floor height up to 4.2mtrs
includingdismantling of existing
accessories as applicable
890 MAT- ELEC-13.2.69 Supplying, erecting & terminating flat 1Mt 150.00
08678 flexible PVC insulated cable 4core
1.0 sq. mm copper conductor
used for railing cables complete
erected with PVC/wooden fastening
arrangement & lugs, on wall /
trunking as per specification
including dismantling of existing
accessories as applicable
891 MAT- ELEC-13.2.70 Supplying, erecting & terminating flat 1Mt 400.00
08679 flexible PVC insulated cable 12core
1.0 sq. mm copper conductor
used for trailing cables complete
erected with pvc/wooden fastening
arrangement & lugs, on wall/
trunking as per specification
including dismantling of existing
accessories as applicable
892 MAT- ELEC-13.2.71 Supplying, erecting, testing & 1Job 63800.00
08680 commissioning programmable rope
mounted Overload Warning Device
(OWD) within built digital indicator
complete with required wiring &
accessories with audio visual
indication in lift car including
dismantling of existing accessories as
applicable.

269
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

Note: 1.For item no 13-2-2....for 11 to 20


passenger capacity lift, add 15% to
the basic cost
2.For item no 13-2-2....for 21 to 29
passenger capacity lift, add 25% to
the basic cost
3.For item nos. 13-2-6 to 13-2-9
main/diverter sheave for additional
groove exceeding 4nos, add 10%
in the basic cost per additional groove
4.For item no's 13-2-33 to 13-2-35 for
Stainless Steel Collapsible doors,
basic cost of MS collapsible
shall be doubled,Note:- This item
shall be operated with prior
permission in writing from the
concern Superintending Engineer
(Electrical).
5.For item no's 13-2-33 to 13-2-35,
If the requirements for landing/car
doors clear height above 2000mm ,
for Manual operated MS door panels
add Rs.1,000/- per 100mm rise per
landing.
6. For item nos. 13-2-36 to 13-2-40
the rates are for automatic
landing/car door with clear height of
2000mm
If the Requirements for landing/car
doors clear height above
2000mm, refer add on item no. 13-1/G
(b)
7.For item no 13-2-47- Providing &
fixing additional Floor button with
allied hardware components on
COP, add Rs.
2500/- per additional button.
8.For item no 13-2-53 & 13-2-54... Lift
Controller for Lift car travelling 9 stops
to 15 stops, add Rs. 27300/-.
9.For item no 13-2-53 & 13-2-54... Lift
Controller for Lift car travelling 16
stops to 21 stops, Rs. 46000/-.
10.For item no 13-2-53 & 13-2-
54....Lift Controller for PowerCircuit
suitable for above 5.5kW & up to
10kW motor, add Rs.7500/-.
11.For item no 13-2-53 & 13-2-54...
Lift Controller for PowerCircuit
suitable for above 10kW & up to 15kW
motor, add Rs.10900/-

270
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

12.For item no 13-2-68 ... For Lift


Shaft Wiring in copper wire/cable,
above 1st floor for lifts with
manually/power operated doors, add
Rs. 2500/- per floor.
13.The cost of dismantled material of
lift parts, shall be calculatedon the
rate analysis based on weight density
calculations of actual dismantled
material e.g. mild steel/MS/GI/SS
sheets, motors, copper wire, wooden
parts etc.
14.The lift dismantled retrieved
material will be handed over to
agency and the calculated amount will
be deducted in the bill.

13.3: DISMANTLING
893 MAT- ELEC-13.3.1 Dismantling the existing 4 to 7 1Job 30000.00
08681 Passenger lift of all types travelling
G+1 floors (2 Landings/2Stops)
having with auto/manual operated
doors for lift car & all landings with
door frames, guide rails,controller,
wiring buffers, Lift Machine, ropes
complete with all allied accessories of
Lift and making the site clear in all
respect complete with refilling the
holes with cement mortar & making
the site as original this job includes
transportation of the dismantled
material upto division/section store
and handing over to the section
engineer/store keeper in charge
complete.

894 MAT- ELEC-13.3.2 Dismantling the existing 8 to 12 1Job 35000.00


08682 Passenger lift of all types travelling
G+1 floors (2 Landings/2Stops)
having with auto/manual operated
doors for lift car & all landings
with door frames, guide
rails,controller, wiring buffers, Lift
Machine, ropes complete with all
allied accessories of Lift and making
the site clear in all respect complete
with refilling the holes with cement
mortar & making the site as original
this job includes transportation of the
dismantled material upto
division/section store and handing
over to the section engineer/store

271
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

keeper in charge complete.

895 MAT- ELEC-13.3.3 Dismantling the existing 13 to 17 1Job 40000.00


08683 passenger/Stretcher/Goods lift of all
types travelling G+1 floors (2
Landings/2Stops) having with
auto/manual operated doors for lift car
& all landings with door frames, guide
rails, controller, wiring buffers, Lift
Machine, ropes complete with all
allied accessories of Lift and making
the site clear in all respect complete
with refilling the holes with cement
mortar & making the site as original
this job includes transportation of the
dismantled material up to
division/section store and handing
over to the section engineer/store
keeper in charge complete
896 MAT- ELEC-13.3.4 Dismantling the existing 18 to 22 1Job 42000.00
08684 Passenger/Stretcher/Goods lift of all
types travelling G+1 floors (2
Landings/2Stops) having with
auto/manual operated doors for lift car
& all landings with door frames, guide
rails, controller, wiring buffers, Lift
Machine, ropes complete with all
allied accessories of Lift and making
the site clear in all respect complete
with refilling the holes with cement
mortar & making the site as original
this job includes transportation of the
dismantled material up to
division/section store and handing
over to the section engineer/store
keeper in charge complete
897 MAT- ELEC-13.3.5 Dismantling the existing 23 to 26 1Job 48000.00
08685 Passenger/Stretcher/Goods lift of all
types travelling G+1 floors (2
Landings/2Stops) having with
auto/manual operated doors for lift car
& all landings with door frames, guide
rails, controller, wiring buffers, Lift
Machine, ropes complete with all
allied accessories of Lift and making
the site clear in all respect complete
with refilling the holes with cement
mortar & making the site as original
this job includes transportation of the
dismantled material up to
division/section store and handing
over to the section engineer/store
keeper in charge complete

272
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5
898 MAT- ELEC-13.3.6 Dismantling the existing 27 to 36 1Job 52000.00
08686 Passenger/Stretcher/Goods liftof all
types travelling G+1 floors (2
Landings/2Stops) having with
auto/manual operated doors for lift car
& all landings with door frames, guide
rails, controller, wiring buffers, Lift
Machine, ropes complete with all
allied accessories of Lift and making
the site clear in all respect complete
with refilling the holes with cement
mortar & making the site as original
this job includes transportation of the
dismantled material up to
division/section store and handing
over to the section engineer/store
keeper in charge complete
899 MAT- ELEC-13.3.7 Dismantling the 3000 to 5000KG 1Job 54000.00
08687 Goods lift of all types travelling
G+1Upper Floors (2
Landings/2Stops) having with
auto/manual operated doors for lift car
& all landings with door frames, guide
rails, controller, wiring buffers, Lift
Machine, ropes complete with all
allied accessories of Lift and making
the site clear in all respect complete
with refilling the holes with cement
mortar & making the site as original
this job includes transportation of the
dismantled material up to
division/section store and handing
over to the section engineer/store
keeper in charge complete
Add On

A If there are addition of floors for lift


travelling up to six floors, add as
given below
MAT- 1 For 4 to 7 passenger lift of all types 1Floor 2500.00
08688

MAT- 2 For 8 to 12 passenger lift of all types 1Floor 2700.00


08689

MAT- 3 For 13 to 17 1Floor 2900.00


08690 passenger/stretcher/goods lift of all
types
MAT- 4 For 18 to 23 1Floor 3300.00
08691 passenger/stretcher/goods lift of all
types
MAT- 5 For 23 to 26 1Floor 3400.00
08692 passenger/stretcher/goods lift of all
types

273
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- 6 For 27 to 36 1Floor 3600.00


08693 passenger/stretcher/goods lift of all
types
MAT- 7 For 3000 to 5000Kg goods lift of all 1Floor 3900.00
08694 types

A1 If there are additional floors for Lift


travelling above Six floors and up
to Fifteen floors Add as given
below
MAT- 1 For 4 to 7 passenger lift of all types 1Floor 2700.00
08695

MAT- 2 For 8 to 12 passenger lift of all types 1Floor 2900.00


08696

MAT- 3 For 13 to 17 1Floor 3300.00


08697 passenger/stretcher/goods lift of all
types
MAT- 4 For 18 to 23 1Floor 3400.00
08698 passenger/stretcher/goods lift of all
types
MAT- 5 For 23 to 26 1Floor 3600.00
08699 passenger/stretcher/goods lift of all
types
MAT- 6 For 27 to 36 1Floor 3900.00
08700 passenger/stretcher/goods lift of all
types
MAT- 7 For 3000 to 5000Kg goods lift of all 1Floor 4100.00
08701 types

A2 If there are additional floors for


Lift travelling above fifteen floors
and up to Twenty floors , add as
given below
MAT- 1 For 4 to 7 passenger lift of all types 1Floor 2900.00
08702

MAT- 2 For 8 to 12 passenger lift of all types 1Floor 3300.00


08703

MAT- 3 For 13 to 17 1Floor 3400.00


08704 passenger/stretcher/goods lift of all
types
MAT- 4 For 18 to 23 1Floor 3600.00
08705 passenger/stretcher/goods lift of all
types

274
Basic Rate
SL.
NO. CFMS ITEM CODE DESCRIPTION OF ITEM Unit for SOR 2021-22
CODE (Rs.)

1 2 3 4 5

MAT- 5 For 23 to 26 1Floor 3900.00


08706 passenger/stretcher/goods lift of all
types
MAT- 6 For 27 to 36 1Floor 4100.00
08707 passenger/stretcher/goods lift of all
types
MAT- 7 For 3000 to 5000Kg goods lift of all 1Floor 4500.00
08708 types

B If there are additional set of lift car


door and landing door, add

as given below

MAT- 1 For 4 to 7 passenger lift of all types 1Set 1800.00


08709

MAT- 2 For 8 to 12 passenger lift of all types 1Set 2000.00


08710

MAT- 3 For 13 to 17 1Set 2100.00


08711 passenger/stretcher/goods lift of all
types
MAT- 4 For 18 to 23 1Set 2400.00
08712 passenger/stretcher/goods lift of all
types
MAT- 5 For 23 to 26 1Set 2100.00
08713 passenger/stretcher/goods lift of all
types
MAT- 6 For 27 to 36 1Set 2500.00
08714 passenger/stretcher/goods lift of all
types
MAT- 7 For 3000 to 5000Kg goods lift of all 1Set 3000.00
08715 types

275
Electrical & Electro Mechanical items
(List of Recommended brands/Manufacturers for guidance of field engineers)

S. Item Code Category Makes


No
.
SECTION - 1
1.1 M.S. CONDUIT PIPES
1 ELEC-1.1.1 …… Makes: NAI / Bharath / GB / AKG/Precision.
1.2 PVC CONDUIT PIPES
2 ELEC1.2.1/ …… Makes : Precision/Universal& Marudhar/VIP / GoldMedal /
1.2.2/1.2.6/1. Million plast / GM / Sudhakar /Polycab/Anchor/ Polyline/
2.7 Orbit/AKG/Beljin
/1.2.8
3 ELEC-1.2.3 …… Makes: Precision/VIP / Modi/ GoldMedal / Million plast / GM /
Sudhakar / Polyline/Orbit/Anchor/Beljin
4 ELEC- …… Make:Precision/ VIP / GoldMedal / Million plast / Sudhakar /
1.2.4 /1.2.5 Polyline
/Anchor/Beljin
1.5 COPPER FLEXIBLE CABLES (AS PER IS:694)
5 ELEC-1.5.1 CATEGORY- I Makes: Finolex / RR kabel / Havells
KEI/Polycab/Gloster/Goldmedal/GM
6 ELEC-1.5.2 CATEGORY- II Makes: V-Guard/Bonton /Finecab/ HPL / Million /Fortune
Art / Sudhakar/Orbit/ Tamra/ Anchor/Plaza/
Vihan/Ollvin/Laser/Beljin/Rhino/ Standard / Vimal
7 ELEC-1.5.3 CATEGORY- III Makes: Star / Airson/ Benlo / Gemscab /Rajnigandha/
Avocab/CRI/Salzer/Spykaar/Unicab/AKG
SHEATHED FLEXIBLE COPPER CABLES
8 ELEC-1.5.4 CATEGORY- I Makes: Finolex / RR kabel / Havells /KEI/Polycab/ Gloster/
Goldmedal/GM
9 ELEC-1.5.5 CATEGORY- II Makes: V-Guard/Bonton /Finecab/ HPL / Million / Fortune
Art /Sudhakar/Orbit/ Tamra/Anchor /Plaza/ Vihan/Spykaar/
Ollvin/Laser/Beljin/Rhino/ Standard/ Vimal
10 ELEC-1.5.6 …… Makes: Finolex / Polycab / Havells / V-Guard / Gold Medal /
GM / Million / Vimal /Airson/CRI/ Tamra/ ollvin/Avocab
1.6 SERVICE MAINS AND FLAT CABLE FOR SUBMERSIBLE
MOTORS.
11 ELEC- …… Makes: Gold Medal / Million / GM / Vimal / Finecab / Nakoda /
1.6.1/1.6.2 Plaza/ Payal / Sudhakar/ Rajnigandha/ Airson/Orbit/ollvin/Beljin
12 ELEC-1.6.3 CATEGORY- I Makes: Finolex / RR Kabel/ Polycab / Havells / KEI/ Gloster/
Goldmedal / GM

13 ELEC-1.6.4 CATEGORY- II Makes: V-Guard / Million / Vihan/Vimal /Finecab/ CRI/


Lubi/Unicab/Hitech/ Spykaar/ Airson/Ollvin/ Laser/
Beljin/Rhino/Sudhakar
1.7 FLUSH TYPE SWITCHES AND ACCESSORIES
14 ELEC-1.7.1 …… Makes: GM G Home / Gold Medal Olive / Million Zoom / Great
white Omega/Koncept/Vimal opel/ Anchor/Vihan/CPL/ Havells
Reo
1.8 MODULAR SWITCHES AND ACCESSORIES
15 ELEC- CATEGORY- I Makes: Legrand (Arteor/Myrius) / Schneider (Clipsal X/ Livia
1.8.1/1.8.3 AB)/ Crabtree Murano or Ducor/L&T-englaze/ GM-(Four-Five)/
Goldmedal(GIFA)
16 ELEC- CATEGORY- II Makes: Legrand Lyncus / Havells Coral or Fabio / L&T/ HPL/
1.8.2/1.8.4 Schneider Livia/ GM-(G NINE/ GX) C&S/ Goldmedal
(Curve/Air) / Million Mway / Logus Platina/ Panasonic Vision /
Salzer S90series/ Precision/Koncept (Samrat/ Qura)
/Ploycab(Levana)/ Anchor-Roma/ IndoAsian/ Pointer/
CPL/Kolors/ Vihan/Hosper/ Vimal
SECTION - 2
2.1 PANEL MOUNTING SWITCH DISCONNECTOR FUSE UNITS
( SDFU )

276
17 ELEC-2.1.1 CATEGORY- I Makes: L&T / Schneider / C&S / ABB / SIEMENS
18 ELEC-2.1.2 CATEGORY- II Makes: Standard / Havells / HPL / Indo Asian / Benlo/Anchor
2.2 ON LOAD CHANGEOVER SWITCHES (OPEN EXECUTION)
19 ELEC-2.2.1 CATEGORY- I Makes: Socomec / L & T / HPL / Havells/ C&S
20 ELEC-2.2.2 CATEGORY- II Makes: ABB / GE / Siemens / Indo Asian / Benlo/Standard
2.3 OFF LOAD CHANGE OVER SWITCHES IN SS
ENCLOUSURE
21 ELEC-2.3.1 CATEGORY- I Makes: HPL / Havells / Standard / Indo Asian / C&S
22 ELEC-2.3.2 CATEGORY- II Makes: Benlo / Million / GoldMedal /GM/ Vimal
2.4 AUTO TRANSFER SWITCH
23 ELEC-2.4.1 …… Makes: Socomec /Hager /ABB/ HPL/L&T/Havells
24 ELEC-2.4.2 …… Makes: Socomec ATysP/ ABB/L&T
2.5 REWIRABLE / DOUBLE BREAK SWITCHES IN SS
ENCLOSURE
25 ELEC-2.5.1 CATEGORY- I Makes: HPL / Havells / Standard / Indo Asian/Benlo
26 ELEC-2.5.2 CATEGORY- I Makes: HPL / Havells / Standard / Indo Asian /Benlo
27 ELEC-2.5.3 CATEGORY- II Makes:Anchor / GM / Million / Sputnik / Sigma / Gold Medal /
Star/Kundan cab/Anchor.
28 ELEC-2.5.4 CATEGORY- II Makes: Anchor / GM / Million / Sputnik / Sigma / Gold Medal /
Star/Kundan cab/Anchor.
2.6 HRC FUSE LINKS (DIN/BOLTED TYPE)
29 ELEC-2.6.1 …… Makes: L & T / G E / C & S / Standard / HPL / Havells /
Siemens / Indo Asian
2.7 PORCELAIN REWIRABLE FUSE UNITS.
30 ELEC-2.7.1 …… Makes: C&S/Standard/HPL/ Sputnik / Million / Gold Medal
/GM/ Benlo
/Anchor
31 ELEC-2.7.2 …… Makes: C&S/Standard/HPL/ Sputnik / Million / Gold Medal /
GM/Benlo/Anchor
2.8 VOLTAGE SURGE PROTECTORS
32 ELEC-2.8.1 …… Makes: Legrand / Siemens / G.E / L&T / Hager/Havells
2.9 PANEL MOUNTING MCCBs
33 ELEC-2.9.1 CATEGORY- I Makes: L&T- D shine / Schneider-CVS/Legrand -DP X3/
Siemens- 3VL / Hager-h3/C&S -Winbreak2/HPL-Techno
34 ELEC-2.9.2 CATEGORY- II Makes: GE / ABB / Havells / Standard / Indo Asian
PANEL MOUNTING ACBs (Microprocessor Based)
35 ELEC-2.9.3 CATEGORY- I Makes: Siemens-3WLETU45B / L&T-U Power Omega(MTX3.5
EC) / Schneider -MVS 6.0V /Legrand-DMX3/C&S Winmaster-
2)/HPL-Techno
36 ELEC-2.9.4 CATEGORY- II Makes:ABB / GE / Indo Asian / Havells
AIR INSULATED BUS DUCT
37 ELEC-2.9.5 …… Makes: Legrand (Zucchini) / C&S/Advance-Anant
38 ELEC-2.9.6 …… Makes: Legrand (Zucchini) / C&S/Advance- Anant
39 ELEC-2.9.7 …… Makes: Legrand (Zucchini) / C&S /Advance-Anant
40 ELEC-2.9.8 …… Makes: Legrand (Zucchini) / C&S/Advance-Anant
SANDWITCH BUSDUCT
41 ELEC-2.9.9 …… Makes: Legrand (Zucchini) / L&T / Schneider/C&S/Advance-
Anant
42 ELEC-2.9.10 …… Makes: Legrand (Zucchini) / L&T / Schiender / C&S /Advance-
Anant
43 ELEC-2.9.11 …… Makes: Legrand (Zucchini) / L&T / Schiender /C&S/Advance-
Anant
44 ELEC-2.9.12 …… Makes: Legrand (Zucchini) / Schiender /C&S/Advance-Anant
45 ELEC-2.9.13 …… Makes: Legrand (Zucchini) / L&T / Schiender /C&S/Advance-
Anant
46 ELEC-2.9.14 …… Makes: Legrand (Zucchini) / L&T / Schiender /C&S/Advance-
Anant
2.1 MCBs (AS PER IS:60898-1:2002)
47 ELEC-2.10.1 CATEGORY- I Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-
5SX4/ Havells STADx /L&T-AU/Indo Asian-Opti pro/ HPL
(Techno)

277
48 ELEC-2.10.2 CATEGORY- II Makes: ABB- S200/Standard / Havells-euro II / C&S /L&T-
Exora/ GM
/Gold Medal/ Anchor/Salzer /Polycab
49 ELEC-2.10.3 CATEGORY- III Makes:Milltec/ Sputnik / Benlo / Vimal /Precision/Amron/Million.
2.11 ISOLATORS CONFIRMS TO I E C 60947 PART-III
50 ELEC-2.11.1 CATEGORY- I Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-
5SX4/ Havells STADx/L&T-AU/Indo Asian-Opti
pro/HPL(Techno)
51 ELEC-2.11.2 CATEGORY- II Makes: ABB- S200/Standard / Havells-euro II / C&S /L&T-
Exora/ GM
/Gold Medal/ Anchor/Salzer /Polycab
52 ELEC-2.11.3 CATEGORY- III Makes: Milltec / Sputnik / Benlo / Vimal/
Precision/Amron/Million.
2.12 RCCBs(ELCB/RCD) CONFIRMS TO IEC:61008 AND
IS:12640-1
53 ELEC-2.12.1 CATEGORY- I Makes: Legrand-DX3 / Schneider-A9/Hager-h3/ Siemens-
5SX4/ Havells STADx/L&T-AU/Indo Asian-Opti
pro/HPL(Techno)
54 ELEC-2.12.2 CATEGORY- II Makes: ABB- S200/Standard / Havells-euro II / C&S /L&T-
Exora/ GM
/Gold Medal/ Anchor/Salzer /Polycab
RCBO CONFIRMS TO IEC:61009-1
55 ELEC-2.12.3 …… Makes: ABB- S200/Standard / Havells-euro II / HPL (Techno) /
C&S
/L&T-Exora/ GM /Gold Medal/ Anchor/Salzer /Polycab
2.13 MCB DISTRIBUTION BOARDS (AS PER IS 8623; IS 13032;
IEC 61439-3)
56 ELEC-2.13.1 CATEGORY- I Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/
Seimens/Havells STADx/L&T-Newrange/Indo Asian-Opti Pro/
HPL (Techno).
57 ELEC-2.13.2 CATEGORY- II Makes: ABB/Standard / Havells-euro II / C&S / L&T/GM /Gold
Medal/Anchor/Salzer/Polycab
58 ELEC-2.13.3 CATEGORY- III Makes:Milltec / Sputnik / Benlo / Vimal/Precision/
Amron/Million.
TPN DBs
59 ELEC-2.13.4 CATEGORY- I Makes: Legrand (Ekinox 3) / Schneider-A9/Hager -Novello+/
Seimens/Havells STADx/L&T-Newrange/Indo Asian-Opti Pro/
HPL (Techno).
60 ELEC-2.13.5 CATEGORY- II Makes: ABB/Standard / Havells-euro II / C&S / L&T/GM /Gold
Medal/Anchor/Salzer/Polycab
61 ELEC-2.13.6 CATEGORY- III Makes: Milltec /Benlo / Vimal /Precision/Amron/Million.
VTPN DBs
62 ELEC-2.13.7 CATEGORY- I Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/
Seimens/Havells STADx/L&T-Newrange/Indo Asian-Opti Pro/
HPL (Techno)
63 ELEC-2.13.8 CATEGORY- I Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/
Seimens/Havells STADx/L&T-Newrange/Indo Asian-Opti Pro/
HPL (Techno).
64 ELEC-2.13.9 CATEGORY- I Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/
Seimens/Havells STADx/L&T-Newrange/Indo Asian-Opti Pro/
HPL (Techno).
65 ELEC- CATEGORY- II Makes: ABB/Standard / Havells-euro II / C&S / L&T/GM /Gold
2.13.10 Medal/Anchor/Salzer
66 ELEC- CATEGORY- II Makes: Siemens / ABB / Standard / Havells /Hager/
2.13.11 C&S/L&T/Anchor
67 ELEC- CATEGORY- II Makes: ABB/Standard / Havells-euro II / C&S / L&T/GM /Gold
2.13.12 Medal/Anchor/Salzer
68 ELEC- CATEGORY- I Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/
2.13.13 Seimens/Crabtree Xpro classique-II/L&T-Newrange/Indo
Asian-Opti Pro/ HPL (Techno).
69 ELEC- CATEGORY- II Makes: ABB/Standard / Havells-euro II / C&S / L&T/GM /Gold
2.13.14 Medal/Anchor/Salzer/Polycab
70 ELEC- CATEGORY- III Makes: Milltec / Sputnik / Benlo / Vimal/Amron/Million.

278
2.13.15
71 ELEC- CATEGORY- I Makes: Legrand(Ekinox 3) / Schneider-A9/Hager -Novello+/
2.13.16 Seimens/Havells STADx/L&T-Newrange/Indo Asian-Opti Pro/
HPL (Techno).
72 ELEC- CATEGORY- II Makes: Siemens / ABB / Standard / Havells / Hager/ C&S
2.13.17 /L&T/ GM /Anchor/Gold Medal /Polycab
73 ELEC- CATEGORY- III Makes: Milltec / Sputnik / Benlo / Vimal/Amron/Million.
2.13.18
SECTION - 3
3.1 STREET LIGHT LUMINAIRES
74 ELEC-3.1.1 CATEGORY- I Makes: Phillips / Crompton / Bajaj / HPL/Surya
75 ELEC-3.1.2 CATEGORY-II Makes: Style lamp / Mahita Electro / Capart / RK /
Prolite/Kiran
76 ELEC-3.1.3 CATEGORY- I Makes: Phillips / Crompton / Bajaj / Surya / Venture / Halonix
77 ELEC-3.1.4 CATEGORY- II Makes: Style lamp / Mahita Electro / Capart / RK /
Prolite/Kiran
78 ELEC-3.1.5 CATEGORY- I Makes: Wipro / G.E. / Phillips / Bajaj / Crompton / Surya /
Venture
79 ELEC-3.1.6 CATEGORY- II Makes: Style lamp / Mahita Electro / Capart / RK /
Prolite/Kiran
80 ELEC-3.1.7 …… Makes: Bajaj / Crompton / Surya / Capart / RK / Prolite
3.2 LED POST TOP LANTERN LUMINAIRES
81 ELEC-3.2.1 …… Makes: Crompton LPTO-40-CDL-M/ Bajaj Celesta BGCL 40
W LED Wh/Wipro LP 02 or equivalent in
Phillips/Keselec/Havells Endura Spring
82 ELEC-3.2.2 …… Make: Keselec MIRI or equivalent in Philips/Wipro
83 ELEC-3.2.3 …… Make: Keselec CAMBRIDGE/ or equivalent in Philips/Wipro
84 ELEC-3.2.4 …… Makes: Crompton / Bajaj/ Wipro/Phillips/Keselec/Havells
3.3 ACCESSORIES FOR MV / SV / MH LUMINAIRES
COPPER BALLASTS
85 ELEC-3.3.1 …… Makes: Phillips / Bajaj / Crompton / Havells / Surya / Venture /
Halonix/HPL
86 ELEC-3.3.2 …… Makes:Style lamp/ Mahita Electro / Capart / RK / Prolite
87 ELEC-3.3.3 …… Makes: Wipro / G.E. / Phillips / Crompton / Bajaj / Surya / HPL
/ Havells / Venture / Capart
88 ELEC-3.3.4 …… Makes: TIBCON / Phillips / Crompton / Bajaj / Surya / Havells.
3.4 LAMPS
89 ELEC-3.4.1 CATEGORY- I Makes: Phillips / Osram / Crompton / Bajaj / Surya / Venture /
Halonix/HPL.
90 ELEC-3.4.2 CATEGORY- II Makes: Style Lamp / Mahita Electro / Capart
3.5 AUTOMATIC STREET LIGHT CONTROL SYSTEMS
91 ELEC-3.5.1 …… Make: Swadeep Nature Switch / Lightmate/ GL/Bajaj
92 ELEC-3.5.2 a …… Make: Swadeep Nature Switch / Light Mate /GL/Bajaj
-e
93 ELEC-3.5.3 a …… Makes : Swadeep /Super tech ( Light Mate )/ L&T /
-c Siemens / Bajaj
3.6 INTERNAL LUMINAIRES
94 ELEC-3.6.1 CATEGORY- I Makes: Wipro / G.E. / Phillips / Crompton /
Bajaj/Havells/HPL/Halonix
95 ELEC-3.6.2 CATEGORY- II Makes: Surya / Havells / Fortune Art/Kiran
96 ELEC-3.6.3 …… Makes: Crompton / Bajaj /Halonix/ Surya / RK / Million / Gold
Medal
97 ELEC-3.6.4 …… Makes: Crompton / Bajaj / Halonix/Surya / RK / Style
Lamp/HPL
98 ELEC-3.6.5 …… Makes: Crompton / Bajaj /Halonix/ Surya / RK / Style Lamp
/HPL
99 ELEC-3.6.6 …… Makes: Crompton / Bajaj / Halonix/ Surya / RK / Style Lamp /
Million / Gold Medal/HPL
100 ELEC-3.6.7 …… Makes: Crompton / Bajaj / Halonix/ Surya / RK / Style Lamp /
Million / Gold Medal/HPL
101 ELEC-3.6.8 …… Makes: Crompton / Bajaj /Halonix/ Surya / RK / Style Lamp /
Million / Gold Medal

279
102 ELEC-3.6.9 …… Makes: Crompton / Bajaj / Halonix/ Surya / RK / Style Lamp /
Million / Gold Medal
103 ELEC-3.6.10 …… Makes: Phillips / Crompton / Bajaj / Halonix/ Surya
104 ELEC-3.6.11 …… Makes: Phillips / Crompton / Bajaj
/Halonix/ Surya
3.7 FLOURSCENT TUBES / CFL LAMPS / LED BULBS
105 ELEC-3.7.1 …… Makes: Phillips / Crompton / Bajaj / Surya / Havells / Style
Lamp / Capart
106 ELEC-3.7.2 …… Makes: Phillips / Crompton / Bajaj / Surya / Style Lamp /
Capart
107 ELEC-3.7.3 …… Makes: Phillips / Crompton / Bajaj / Surya / Style Lamp /
Capart
108 ELEC-3.7.4 …… Makes: Wipro / G.E. / Phillips / Crompton / Bajaj / Havells /
Surya / HPL / Halonix.
LED BULBS
109 ELEC-3.7.5 …… . Makes: Phillips /Crompton / Bajaj / Havells /
Halonix/GM/HPLSyska / Green Lites / Fortune Art / GoldMedal
/ Luker/Leo/Orbit /Rhino / GLO LED
110 ELEC-3.7.6 …… Makes: Phillips /Crompton / Bajaj / Havells /
Halonix/GM/HPLSyska / Green Lites / Fortune Art / GoldMedal
/ Luker/Leo/Orbit/Rhino /GLO LED
111 ELEC-3.7.7 …… Makes : Philips/Bajaj / Crompton / Havells/ HPL.
3.8 LED LUMINAIRES INDOOR
DOWN LIGHTERS
112 ELEC-3.8.1 CATEGORY- I a) LUMINAIRE MAKE : Phillips / GE-Venture / Crompton /
Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites /
Gold Medal/Eveready/ FortuneArrt b) LED MAKE : PHILIPS
LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/Everlight
113 ELEC-3.8.2 CATEGORY- II Makes : Surya /C&S / Syska / Enrich / Stanjo / Polycab/ Ib
LED/ Opple/R LED/Luker/ Orbit/Trinic /Panasonic /Rhino/ GLO
LED /Vimal
b) LED MAKE : CREE / NICHIA / OSRAM / SAMSUNG /
EVERLIGHT
114 ELEC-3.8.3 CATEGORY- III a) LUMINAIRE MAKE : Pasolite / Cosmo / Siger/ Koncept/
Kiran/Vibrant/Leo/Lumens/Ilite/Akarui
b) LED MAKE : CREE / NICHIA / OSRAM / SAMSUNG /
EVERLIGHT
LED PANEL LIGHTS
115 ELEC-3.8.4 CATEGORY- I a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton /
Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites /
Gold Medal/Eveready/ FortuneArrt b) LED MAKE : PHILIPS
LUMILEDS / CREE / NICHIA / OSRAM / SAMSUNG/Everlight.
116 ELEC-3.8.5 CATEGORY- II Makes : Surya /C&S / Syska / Enrich / Stanjo / Polycab/ Ib
LED/ Opple/ Luker/ Orbit/Trinic/Lumens/Panasonic /Rhino/
GLO LED/ Vimal
b) LED MAKE : CREE / NICHIA / OSRAM / SAMSUNG /
EVERLIGHT
117 ELEC-3.8.6 a CATEGORY- III a) LUMINAIRE MAKE : Pasolite / Cosmo / Siger/ Koncept/
to f Kiran/Vibrant/Leo/Ilite/Akaruib) LED MAKE : CREE / NICHIA /
OSRAM / SAMSUNG / EVERLIGHT/ San'an
COB DOWN LIGHTS
118 ELEC-3.8.7 CATEGORY- I a) LUMINAIRE MAKE : Phillips / GE-Venture / Crompton /
Wipro / Bajaj
/ Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold Medal
/Eveready/ FortuneArrt
b) LED MAKE : Bridge Lux / LUMILEDS / CREE / NICHIA /
Epistar/ Sunpo/Samsung
119 ELEC-3.8.8 CATEGORY- II Makes : Surya /C&S / Syska / Enrich / Stanjo / Polycab/ Ib
LED/ Opple/Luker/ Orbit/ Trinic/Panasonic/Lumens/Panasonic
/Rhino /GLO LED /Vimal/Akarui
b) LED MAKE : Bridge Lux / LUMILEDS / CREE / NICHIA /
Epistar/ Sunpo/Samsung
SPOT LIGHTS / WALL WASHERS

280
120 ELEC-3.8.9 CATEGORY- I a) LUMINAIRE MAKE : Phillips / GE-Venture / Crompton /
Wipro / Bajaj/ Havells / Halonix/Jaquar/HPL/GM / GreenLites /
Gold Medal/Eveready/ FortuneArrt
b) LED MAKE : Bridge Lux / LUMILEDS / CREE / NICHIA /
Epistar/ Sunpo
121 ELEC-3.8.10 CATEGORY- II Makes : Surya /C&S / Syska / Enrich / Stanjo / Polycab/ Ib
LED/ Opple/R LED/Luker/ Orbit/Trinic/Panasonic/Akarui
b) LED MAKE : Bridge Lux / LUMILEDS / CREE / NICHIA /
SAMSUNG/ Sunpo
122 ELEC-3.8.11 CATEGORY- I a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton /
Wipro / Bajaj / Havells / Halonix/ GreenLites/HPL
/Eveready/ FortuneArrt
b) LED MAKE :Bridge Lux / LUMILEDS / CREE / NICHIA /
Epistar.
123 ELEC-3.8.12 CATEGORY- II Makes : Surya / Polycab/ Opple /Luker/ Orbit/Akarui
b) LED MAKE : Bridge Lux/ CREE / NICHIA / Epistar
LED BATTENs AND 2' x 2' LUMINARIES
124 ELEC-3.8.13 CATEGORY- I a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton /
Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites /
Gold Medal/Eveready
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG/ Everlight.
125 ELEC-3.8.14 CATEGORY- II Makes : Surya /C&S/ Fortune Art / Syska / Enrich / Stanjo /
Polycab/ Ib LED/ Opple/ Luker/ Orbit/
Trinic/Lumens/Panasonic/ Rhino/ GLO LED / Vimal
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG / EVERLIGHT
126 ELEC-3.8.15 CATEGORY- III a) LUMINAIRE MAKE : Pasolite / Cosmo / Siger/ Koncept/
Kiran/Vibrant/Leo/ilite/Akarui
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG / EVERLIGHT
127 ELEC-3.8.16 CATEGORY- I a) LUMINAIRE MAKE : Phillips / GE- Venture / Crompton /
Wipro / Bajaj / Havells / Halonix/Jaquar/HPL/GM / GreenLites /
Gold Medal/Eveready
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG.
128 ELEC-3.8.17 CATEGORY- II Makes : Surya /C&S/ Fortune Art / Syska / Enrich / Stanjo /
Polycab/ Ib LED/ Opple/ Luker/ Orbit/
Trinic/Lumens/ilite/Panasonic /Rhino/ GLO LED/ Vimal/Akarui
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG / EVERLIGHT
129 ELEC-3.8.18 …… Makes: Phillips / Crompton / Bajaj/Surya/Havells/HPL
130 ELEC-3.8.19 …… Makes: Greenlites / Fortune Art / Capart / GM
/ Goldmedal /Trinic/Kiran.
131 ELEC-3.8.20 CATEGORY- I a) LUMINAIRE MAKE : Phillips / GE-Venture / Crompton /
Wipro / Bajaj
/ Havells / Halonix/Jaquar/HPL/GM / GreenLites / Gold
Medal/Eveready / FortuneArrt
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG/Everlight.
132 ELEC-3.8.21 CATEGORY- II Makes : Surya /C&S / Syska / Enrich / Stanjo / Polycab/ Ib
LED/ Opple/ Luker/ Orbit/Panasonic/Trinic/ilite/Panasonic
/Rhino /GLO LED/ Vimal/Akarui
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG / EVERLIGHT.
133 ELEC-3.8.22 …… Makes : Philips/Bajaj/ Crompton / Surya / Havells / Greenlites/
Insta Power/HPL /Halonix/ Panasonic. / FortuneArrt
134 ELEC-3.8.22 …… a) LUMINAIRE MAKE : Phillips (Pureline Slim) / GE-Venture /
Crompton / Wipro / Bajaj / Havells (Dustello)
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG/LG

281
135 ELEC-3.8.23 CATEGORY- I a) LUMINAIRE MAKE : Wipro(Skyline) / Philips (Green line) /
GE-Venture / Crompton(Neo Series) / Bajaj (Edge) /
Halonix(Lumos - Super) / Havells (Endura Series)
/Capart(Premium)/Greenlites(Hi-Lux) /Polycab/Keselec/
HPL(City Vision)/ Jaquar(Premium)/Eveready/ Surya (Pollux) /
FortuneArrt (Leaf)
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG / LG
136 ELEC-3.8.24 CATEGORY- I a) Luminaire Make : Wipro(Skyline) / Philips (Greenline Extra) /
GE- Venture / Crompton(Nexus / Hawk series) / Bajaj (Edge)
/ Halonix (Modular/ Lumos-Super) / Havells (Endura
Series)/Greenlites(HI-Lux) /Capart(Premium)/Polycab/Keselec
/ HPL(City Vision)/Jaquar (Premium) /Eveready /Surya (Pollux)
/ Fortune Art (Leaf)
b) LED MAKE :PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG / LG.
137 ELEC-3.8.25 CATEGORY- II a) LUMINAIRE Makes: Syska / GM / C&S/ VIN/Gold Medal
/Pharox / Cosmo / Enrich/Pro-lite(I) / Renesola / Stanjo /
Goldwyn/ Ib LED/ Orbit/ Luker/Trinic/Rhino / GLO LED/ Vimal
b) LED MAKE : CREE / NICHIA / OSRAM / SAMSUNG / LG.
138 ELEC-3.8.26 CATEGORY- III a) LUMINAIRE Makes : Trinic / Pasolite /
Sieger/Koncept/Vibrant/Leo/Lumens/Ilite/Akarui
b) LED MAKE : CREE / NICHIA / OSRAM / SAMSUNG / LG.
FLOOD LIGHTS
139 ELEC-3.8.27 CATEGORY- I a) LUMINAIRE MAKE : Wipro / Philips/ GE-Venture /
Crompton/ Bajaj
/Greenlites / Havells/Capart(Premium) /Halonix/ Polycab
/Keselec/HPL/Jaquar/Eveready / Surya (Lumasmax / O Flood)
/ FortuneArrt (Fin)
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG.
140 ELEC-3.8.28 CATEGORY- II a) LUMINAIRE Makes: Pharox / GM / Goldmedal / Syska /
C&S/Cosmo/ Ib LED/ Vibrant/ Stanjo/Enrich/
Orbit/Luker/Trinic/Pro- lite/Ilite/Rhino /GLO LED /Vimal/Akarui
b) LED MAKE : CREE / NICHIA / OSRAM / SAMSUNG / LG
HIGH BAY LIGHTS
141 ELEC-3.8.29 CATEGORY- I
a) LUMINAIRE MAKE : Wipro / Philips/ GE-Venture /
Crompton/ Bajaj
/Greenlites / Havells/Capart(Premium)
/Halonix/Polycab/Keselec/ HPL/ Jaquar/Eveready / Surya
(ORION-II)/ FortuneArrt (UFO-S)
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG .
142 ELEC-3.8.30 CATEGORY- II a) LUMINAIRE Makes: Pharox / GM / Goldmedal / Syska /
C&S/Cosmo/ Ib LED/ Vibrant/
Stanjo/Enrich/Orbit/Luker/Trinic/Ilite/Rhino/ GLO LED/Akarui
b) LED MAKE : CREE / NICHIA / OSRAM / SAMSUNG.
143 ELEC-3.8.31 …… UMINAIRE MAKE : Wipro / Philips/ GE / Crompton/ Bajaj /
Greenlites/ Havells/ FortuneArrt
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG/Seoul .
RGB/RGBW LED Lighting
144 ELEC-3.8.32 …… LUMINAIRE MAKE : Wipro / Philips/ Crompton/ Bajaj /
Greenlites/ Havells/ FortuneArrt
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG/Seoul .
145 ELEC-3.8.33 …… a) LUMINAIRE MAKE : Wipro / Philips/ GE / Crompton/ Bajaj /
Greenlites/ Havells/ FortuneArrt
b) LED MAKE : PHILIPS LUMILEDS / CREE / NICHIA /
OSRAM / SAMSUNG /SEOUL.
146 ELEC-3.8.34 …… Make: Sunlite Suit2/Artnet or its equivalent
147 ELEC-3.8.35 …… Makes:colourdreamer/ AURA/Greenlites

282
148 ELEC-3.8.36 …… Makes:colourdreamer/ AURA/Greenlites
149 ELEC-3.8.37 …… Makes:colourdreamer/ AURA/Greenlites
150 ELEC-3.8.38 …… Makes:Mean Well or its equivalent
151 ELEC-3.8.39 …… Makes:Mean Well or its equivalent
LED DRIVERS
152 ELEC-3.8.40 …… Makes: Philips /Crompton / Bajaj/
Havells/Surya/Greenlites/HPL/Halonix/Jaquar/Ib
LED/Promtec/Eveready
153 ELEC-3.8.41 …… Makes: Philips /Crompton / Bajaj/
Havells/Surya/Greenlites/HPL/Halonix/Jaquar/Ib
LED/Promtec/Eveready/Stanjo
SECTION - 4
4.1 U.G. CABLES
154 ELEC-4.1.1 CATEGORY- I Makes: Torent / Universal / Unicab / Havells / KEI /
Gloster/Finecab / Polycab /RR Kabel
155 ELEC - 4.1.2 CATEGORY- II Makes: RPG / Finolex / Paragon / V-Guard / Fortune Art /
Suncab / Delton / Payal / Gemscab/ Orbit/Avocab/Laser/Rhino.
33 KV HT XLPE CABLES
156 ELEC-4.1.3 …… Make: Torrent / Universal / Unicab / Havells / KEI
/Polycab/Gloster/RR Kabel/RPG
11 KV HT XLPE CABLES
157 ELEC- 4.1.4 …… Make: Torrent / Universal / Unicab / Havells / KEI
/Polycab/Gloster/RR Kabel/RPG
Un Armoured and Armoured Copper Control Cables
158 ELEC-4.1.5 …… Make: Torrent / Universal / Unicab / Havells / KEI
/Polycab/Gloster /orbit
/ Paragon/ RR Kabel/ RPG
159 ELEC-4.1.6 …… Make: Torrent / Universal / Unicab / Havells / KEI
/Polycab/Gloster/Orbit/ Paragon/RR Kabel/RPG/Rhino
CABLE TERMINATIONS AND ACCESSORIES
160 ELEC-4.1.7 …… Makes: Raychem /M seal/ Denson/ Multy/ Transeal-
Hongshang
161 ELEC-4.1.8 …… Makes: Raychem /M seal/ Denson/ Multy/ Transeal-
Hongshang
162 ELEC-4.1.9 …… Makes: Raychem /M seal/ Denson/ Multy/ Transeal-
Hongshang
163 ELEC-4.1.10 …… Makes:Dowels/Comet/SMI
164 ELEC-4.1.11 …… .Makes:Dowels/Comet/SMI
165 ELEC-4.1.12 …… Makes:Dowels/Jainson/Comet
166 ELEC-4.1.13 …… Makes:Dowels/Jainson/Comet
4.3 DOUBLE WALLED CORRUGATED HDPE PIPE
167 ELEC-4.3.1 …… Makes:DURA LINE (Dura Guard)/Precision or its equivalent
a- h make.
SECTION - 5
5.1 FANS
168 ELEC-5.1.1 …… Makes : Atomberg(Gorilla GV2 )/ Halonix(Plasma)
/Havells(Efficiencia Neo)
169 ELEC-5.1.2 …… Makes : Atomberg(Gorilla GV2 )/ Halonix(Plasma)
/Havells(Efficiencia Neo)
170 ELEC-5.1.3 …… Makes : Crompton HS Plus / Havells ES PLUS/Orient Energy
Star/ Halonix(Zephyr)/Polycab(Synergy 50 ISI) / G.M. (Air
Wave Premium)
171 ELEC-5.1.4 …… Makes: Crompton (HS Decora/Aura) / Bajaj Regal Star /
Havells Festiva / Orient Ornamental Shine/Halonix(Halo)
/Polycab(Elanza)/G.M. (G-Storm)
172 ELEC-5.1.5 …… Makes : Crompton HS / Havells Velocity ES 50/Orient
Summer Breeze Pro
/Halonix(Zephyr)/Polycab(Synergy 50 ISI)
173 ELEC-5.1.6 …… Makes: Crompton Wind Flo / Bajaj Elite / Havells Swing /
Orient Wall 50/Halonix Krypton/G.M. (Bolt)/ Goldmedal(Nora-
16)

283
174 ELEC-5.1.7 …… Makes: Crompton Wind Flo / Bajaj Spectrum / Havells Swing /
Orient Stand 37/Halonix Krypton/Polycab / G.M.
(Bolt)/Goldmedal(Nora-16)
175 ELEC-5.1.8 …… Makes: Crompton / Havells Turbo Force / Orient Tornado II /
Almounard/Halonix Turbon/Polycab./ G.M. (Air-Burst)
176 ELEC-5.1.9 …… Makes: Crompton / Havells Turbo Force / Almounard/Halonix
177 ELEC-5.1.10 …… Makes: Crompton / Havells ciera / Orient Wall 11/Halonix
178 ELEC-5.1.11 …… Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DSP /
Orient hill air/Halonix /Polycab/G.M. (Xenix)/Goldmedal
(Rapido-12)
179 ELEC-5.1.12 …… Makes: Crompton / Bajaj Bahar WG / Havells Ventil Air-DSP /
Orient hill air/Halonix /Polycab/ G.M. (Xenix)/Goldmedal
(Rapido-9)
180 ELEC-5.1.13 …… Makes: Crompton / Almounard / Havells Ventil Air-DB
181 ELEC-5.1.14 …… Makes: Crompton / Almounard / Havells Turbo Force/Halonix
Krypton
182 ELEC-5.1.15 …… Makes: Crompton / Almounard / Havells Turbo Force/Halonix
Krypton
5.2 WATER HEATERS (Conventional & Solar)
183 ELEC-5.2.1 …… Makes : Crompton Solarium (Neo/Qube) / Jaquar Elena /
Venus Lyra / Racold Andris Lux Plus / AO Smith HSE SDS
Plus /Havells Puro DX/Warmex
184 ELEC-5.2.2 …… Make:TATA / BHEL/ BOSCH/ ETC/V-GUARD /RACOLD
185 ELEC-5.2.3 …… Make:TATA / BHEL/ BOSCH/ ETC/V-GUARD /RACOLD
186 ELEC-5.2.4 …… Make:Jaquar/AO Smith/Voltex/Racold /Rheem
187 ELEC-5.2.5 …… Make:Jaquar/AO Smith/Voltex/Racold /Rheem
5.4 PUMPSETS
SINGLE PHASE SUBMERSIBLE MOTOR PUMP SETS
188 ELEC-5.4.1 CATEGORY- I Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi/
PSG/AryenVarsha/ Falcon
189 ELEC-5.4.2 CATEGORY- II Makes: Pluga / Sterling / Kumar / Unnati
zen/Duke/Lada/Ellen/
Suguna/UNItek/KSP(Karunya)/Anco/Sabar/Fitwell/Deccan
/Karvel / SILVER
THREE PHASE SUBMERSIBLE MOTOR PUMP SETS.
190 ELEC-5.4.3 CATEGORY- I Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi/
PSG/AryenVarsha/Falcon
191 ELEC-5.4.4 CATEGORY- II Makes: Pluga / U-Neel / Sterling / Kumar / Unnati
zen/Duke/Lada/Ellen/ Suguna/ UNItek/KSP(Karunya)/ Anco/
Sabar/ Fitwell/Deccan/Karvel/ SILVER
192 ELEC-5.4.5 CATEGORY- I Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi/
PSG/AryenVarsha/Falcon
193 ELEC-5.4.6 CATEGORY- II Makes: Pluga / U-Neel / Sterling /Kumar / Unnati
zen/Duke/Lada/Ellen/ Suguna/UNItek /KSP (Karunya) /Anco/
Sabar/Fitwell/Polycab/Deccan/Karvel/ SILVER
SINGLE PHASE OPEN WELL SUBMERSIBLE MOTOR
PUMP SETS
194 ELEC-5.4.7 CATEGORY- I Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi/PSG/
AryenVarsha/Falcon
195 ELEC-5.4.8 CATEGORY- II Makes: Pluga / U-Neel / Sterling / Kumar / Unnati
zen/Duke/LDK/Ellen/ Suguna/UNItek /KSP (Karunya) / Anco/
Sabar/Fitwell/Deccan/Karvel/ SILVER
THREE PHASE OPEN WELL SUBMERSIBLE PUMP SETS
196 ELEC-5.4.9 CATEGORY- I Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi /PSG/
AryenVarsha/Falcon
197 ELEC-5.4.10 CATEGORY- II Makes: Pluga / U-Neel / Sterling / Kumar / Unnati
zen/Duke/LDK/Ellen/ Suguna/UNItek/ KSP(Karunya) /Polycab/
Anco/ Sabar /Fitwell/Deccan/Karvel/ SILVER
SINGLE PHASE MONO BLOCK MOTOR PUMP SETS.
198 ELEC-5.4.11 CATEGORY- I Makes: Kirloskar / Crompton / Texmo / CRI / KSB/Lubi /
Havells Hi-flow V2 / PSG/AryenVarsha/Falcon

284
199 ELEC-5.4.12 CATEGORY- II Makes: Pluga / U-Neel / Sterling /Kumar / Unnati
zen/Ellen/LDK/Suguna/ UNItek/Polycab/Anco/
Sabar/Fitwell/Deccan/Karvel / SILVER
200 ELEC-5.4.13 CATEGORY- I Makes: Kirloskar / Crompton / Texmo / CRI / KSB /Lubi/
AryenVarsha/Falcon
201 ELEC-5.4.14 CATEGORY- II Makes: Pluga / U-Neel / Sterling /Kumar / Unnati
zen/Ellen/LDK/Suguna/ UNItek/Polycab/Anco/
Sabar/Fitwell/Deccan/Karvel/ SILVER
CONTROL PANEL BOARD FOR MOTOR PUMPSETS
202 ELEC-5.4.15 …… make C&S/LTLK/ Seimens/ BCH/KSP(Karunya)/ Crompton.
complete.,
203 ELEC-5.4.16 …… make C&S/LTLK/Seimens/BCH
/KSP(Karunya) /Crompton. complete.,.
204 ELEC-5.4.17 …… Voltmeter ;. Makes: L&T / C&S / SALZAR / HPL/ AEI / Meco /
Rishab
Ammeter Makes: L&T / C&S / SALZAR / HPL/ AEI / Meco /
Rishab
Single phase preventor Makes: L&T / Minilec / Powertec.
32 A TP, 10KA MCB. Makes: Legrand / Schneider
capacitor Makes: L&T / Siemens / Schneider / Epcos/Havells.
a …… Make C&S.Crompton / L&T /KSP/ Siemens/BCH.
b …… Make C&S/Crompton / L&T / Siemens/BCH.
c …… Make C&S/Crompton / L&T / Siemens/BCH.
205 ELEC-5.4.18 …… Makes: Siemens / Crompton / L&T (MF1)
206 ELEC-5.4.19 …… Makes: Siemens / Crompton / L&T (MK2 DOL).
207 ELEC-5.4.20 …… Makes: Siemens / Crompton / L&T (MU1 DOL)
UPVC PIPES AND FITTINGS
208 ELEC-5.4.21 …… Makes : Ashirvad / Finolex / Waterflo /Sudhakar/Precision.
209 ELEC-5.4.27 …… Makes : Ashirvad / Finolex / Waterflo
210 ELEC-5.4.28 …… Makes : Ashirvad / Finolex / Waterflo / Apollo
5.1 AIR CONDITIONERS
211 ELEC-5.5.1 1.5TR Split ACs
a CATEGORY- I Makes: Mitsubishi MS-GK 18VA / O General ASGG18CPTA-
B/Toshiba RAS-18J2KG-IN
b CATEGORY- II Makes: Blue Star FS318YBTU / Daikin FTL Sereis / Hitachi /
Voltas / Carrier Emperia Nx /LG-Q18PNXA
2.0 TR Split Acs
c CATEGORY- I Makes: Mitsubishi MS- GK24VA / O General ASGG24CPTA-B/
Toshiba RAS-24J2KG-IN
d CATEGORY- II Makes: / Hitachi / Blue Star FS324YATU / Daikin / Voltas
/Carrier Emperia Nx/ LG-Q24HNXA
Inverter Split AC Unts (Cooling Only)
212 ELEC-5.5.2 0.8/ 1.0TR Split Acs
a CATEGORY- I Makes: Mitsubishi MSY-GN10VF/ O General ASGG12CGTA-
B/ Toshiba
b CATEGORY- II Makes: Blue star /Carrier /Hitachi/Daikin/ LG-Q12KNZA
c CATEGORY- I Makes: Mitsubishi MSY-GN13VF/ O General ASGG14CGTA-
B/ Toshiba RAS-13U2KCVSG-IN
d CATEGORY- II Makes: Blue Star IC512DATUL / Carrier Emperia Nxi / Hitachi
/ Daikin/ LG-Q12KNZA
1.5, 1.8 & 2.0TR Split Acs
e CATEGORY- I Makes: Mitsubishi MSY-GN18VF / O General
ASGG18CGTA-B/Toshiba RAS-18U2KCVSG-IN
f CATEGORY- II Makes: / Blue Star IC718DCTU / Daikin FTKG50TV16U /
Hitachi/Carrier Emperia Nxi / LG-Q18KNZA
g CATEGORY- I Makes: Mitsubishi MSY-GN22VF / O General /Toshiba
h CATEGORY- II Makes: Blue star / Hitachi / Daikin
i CATEGORY- I Makes: Mitsubishi MSY- GN26VF /O General ASGG24CGTA-
B/Toshiba RAS-24U2KCVSG-IN
j CATEGORY- II Makes: Blue star IC524DBTU / Hitachi / Daikin/Carrier
Emperia Nxi

285
INVERTER CASSETTE TYPE AC UNITS
213 ELEC-5.5.35
a CATEGORY- I Makes: Mitsubishi PLY- SP18EA / Toshiba RAV-SE561UP / O
General.
b CATEGORY- I Makes: Mitsubishi PLY- SP24EA / O General AUGA25FRTA-
B / Toshiba RAV-SE801UP
c CATEGORY- II Makes: Blue Star3HNCS24YAF/ Daikin / Carrier/ LG
d CATEGORY- I Makes: Mitsubishi PLY- SP42EA / O General /Toshiba
e CATEGORY- II Makes: Daikin / Bluestar / Carrier
f CATEGORY- I Makes: Mitsubishi PLY-SP48EA / O General / Toshiba RAV-
SE1251UP
g CATEGORY- II Makes: Blue Star / Carrier / Daikin/LG
TOWER MODEL (Vertical) TYPE AC UNITS
214 ELEC-5.5.36
a …… Makes: Carrier /Daikin / Blue Star
b …… Makes: Carrier /Daikin / Blue Star
c …… Makes: Carrier /Daikin / Blue Star
HVAC SYSTEMS(VRV/VRF)
215 ELEC-5.6.1 CATEGORY- I Makes: Mitsubishi /DAIKIN/Toshiba/O General
216 ELEC-5.6.2 CATEGORY- II Makes: LG/Voltas/Blue star/Hitachi/Carrier/Samsung
217 ELEC-5.6.6 CATEGORY- I Makes: Mitsubishi /DAIKIN/Toshiba/ O General
218 ELEC-5.6.7 CATEGORY- II Makes: LG/Voltas/Blue star/Hitachi/Carrier/Samsung
219 ELEC-5.6.8 CATEGORY- I Makes: Mitsubishi /DAIKIN/Toshiba /O General
220 ELEC-5.6.9 CATEGORY- II Makes: LG/Voltas/Blue star/Hitachi/Carrier/Samsung
221 ELEC-5.6.10 CATEGORY- I Makes: Mitsubishi /DAIKIN/Toshiba/ O General
222 ELEC-5.6.11 CATEGORY- II Makes: LG/Voltas/Blue star/Hitachi/Carrier/Samsung
223 ELEC-5.6.13 CATEGORY- I Makes: Mitsubishi /DAIKIN/Toshiba/ O General
224 ELEC-5.6.14 CATEGORY- II Makes: LG/Voltas/Blue star/Hitachi/Carrier/Samsung
Refrigerant Piping
225 5.6.20 …… Makes:Totaline/Mandav/Mexico
226 ELEC-5.6.25 …… Makes:TATA/Jindal
5.7 EVAPORATIVE AIR COOLING SYSTEM
227 ELEC-5.7.1 …… Makes: Cool Breeze / Breeze Air
228 ELEC-5.7.2 …… Makes: Cool Breeze
/Breeze Air
STABILIZERS
229 ELEC-5.8.1 CATEGORY- I Makes: V-Guard / Real Guard / Uni Stab / ITL.
230 ELEC-5.8.2 CATEGORY- II Makes: Keeline / Soft Line
5.9 REPAIRING OF FANS, COOLERS, PUMPS, MOTORS,
FRIDGES AND AIRCONDITIONERS
231 ELEC-5.9.16 …… Makes:Carrier/ Kirlosker/ Techam-Shah/ Shriram/ Voltas
232 ELEC-5.9.17 …… Makes: DAIKIN/LG/Carrier/Kirloskar/Techam-shah
233 ELEC-5.9.25 …… Make: Copper:Totaline /Nippon /Mandev/Nitrile Insulation:
Kflex/ Totaline /Armaflex
234 ELEC-5.9.26 …… Makes : Crompton / AU.
SECTION 6
6.1 SWAGED / OCTAGONAL POLES AND GARDEN POSTS
OCTOGONAL POLEs
235 ELEC-6.1.4 …… Makes: Bajaj / Valmont/Laasma
/Transrail/Utkarsh/ Skipper/Consoul
236 ELEC-6.1.5 …… Makes: Bajaj / Valmont/Laasma
/Transrail/Utkarsh/ Skipper/Consoul
237 ELEC-6.1.6 …… Makes: Bajaj / Valmont/Laasma/Transrail/Utkarsh/
Skipper/Consoul
238 ELEC-6.1.7 …… Makes: Bajaj / Valmont/Laasma//Transrail/Utkarsh/
Skipper/Consoul
DECORATIVE DRAGON TYPE BRACKET WITH POLE
239 ELEC-6.1.8 …… Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/
Skipper/Consoul
240 ELEC-6.1.10 …… Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/
Skipper/Consoul

286
POLE BRACKETS
241 ELEC-6.1.11 …… Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/
Skipper/Consoul
242 ELEC-6.1.12 …… Makes: Bajaj / Valmont/Laasma //Transrail/Utkarsh/
Skipper/Consoul
243 ELEC-6.1.13 …… Makes: Bajaj / Valmont/Laasma//Transrail/Utkarsh/
Skipper/Consoul
244 ELEC-6.1.14 …… Makes: Bajaj / Valmont/Laasma//Transrail/Utkarsh/
Skipper/Consoul
245 ELEC-6.1.15 …… Makes: Bajaj / Valmont/Laasma//Transrail/Utkarsh/
Skipper/Consoul
246 ELEC-6.1.16 …… Makes: Bajaj / Valmont/Laasma//Transrail/Utkarsh/
Skipper/Consoul
247 ELEC-6.1.17 …… Makes: Bajaj / Valmont/Laasma//Transrail/Utkarsh/
Skipper/Consoul
248 ELEC-6.1.18 …… Makes: Bajaj / Valmont/Laasma//Transrail/Utkarsh/
Skipper/Consoul
249 ELEC-6.1.19 …… Makes: Bajaj / Valmont/Laasma//Transrail/Utkarsh/
Skipper/Consoul
250 ELEC-6.1.20 …… Makes: Bajaj / Valmont/Laasma//Transrail/Utkarsh/
Skipper/Consoul
HIGH MAST POLES
251 ELEC-6.1.21 …… Makes: Bajaj / Valmont/Laasma/Transrail/Utkarsh/
Skipper/Consoul
252 ELEC-6.1.22 …… Makes: Bajaj / Valmont/Laasma/Transrail/Utkarsh/
Skipper/Consoul
253 ELEC-6.1.23 …… Makes: Bajaj / Valmont/Laasma /Transrail/Utkarsh/
Skipper/Consoul
FEEDER PILLAR BOXES
254 ELEC-6.1.24 …… FP MCBmake :Legrand / Schnieder / L&T
255 ELEC-6.1.25 …… FP MCBmake :Legrand / Schnieder / L&T
ERRECTION- HIGH MAST POLES
256 ELEC-6.1.29 …… Make : Hensel/Sadhrish
GRP POLES
257 ELEC-6.1.34 …… Makes: Bajaj / Kemrock / Valmont/Sumip/Helipole
258 ELEC-6.1.35 …… Makes: Bajaj / Kemrock / Valmont/Sumip / Helipole
6.2 LT PANEL AND ACCESSORIES
259 ELEC-6.2.3 …… .Make: Conzerve/Elmeasure/Meco/HPL/L&T/socomec
260 ELEC-6.2.4 …… Make: Conzerve/Elmeasure/
Meco/HPL/L&T/Schneider/AE/Socomec
261 ELEC-6.2.5 …… Make: Kappa/L&T/Seimens/C&S/Schneider
262 ELEC-6.2.6 …… Make: L&T /C&S/SALZER/HPL
263 ELEC-6.2.7 …… Make: L&T /C&S/SALZER/HPL

264 ELEC-6.2.8 …… Makes: CONZERVE / ELMEASURE / MECO / HPL /


HAVELLS/L&T.
265 ELEC-6.2.12 …… Makes: L&T/Seimens/Epcos/Schneider/Havells
266 ELEC-6.2.13 …… Makes: L&T/Seimens/Epcos /Schneider/ ABB/Neptune
267 ELEC-6.2.14 …… makes: L&T (SALZER)/ABB/Schneider/Seimens/C&S/HPL
268 ELEC-6.2.15 …… Make:Seimens/ABB/Schneider/L&T/C&S/HPL/Havells
269 ELEC-6.2.16 …… Make:Seimens/ABB/Schneider/L&T/C&S/HPL/Havells
270 ELEC-6.2.17 …… Make:Seimens/ABB/Schneider/L&T/C&S/HPL/Havells
271 ELEC-6.2.18 …… Make:Seimens/ ABB/ Schneider/L&T/C&S/HPL
6.3 SUB STATION EQUIPMENT AND TRANSFORMERS
272 ELEC-6.3.1 …… make:as approved By DISCOMs
273 ELEC-6.3.1a …… Make:ABB/ Megawin/Amara Raja/L&T
274 ELEC-6.3.2 Makes:ABB/Schneider/Seimens/Kirlos kar/Amara
Raja/Megawin/L&T
275 ELEC-6.3.3 …… Makes:ABB/Schneider/Seimens/Kirlos kar/Amara
Raja/Megawin/L&T
Oil Immersed TRANSFORMERS
276 ELEC-6.3.4 CATEGORY- I Make:ABB/ALSTOM/SEIMENS/Kirloskar/Voltamp/

287
Esennar/KPEL/SSE
277 ELEC-6.3.4 A CATEGORY- II Make:THOTA
278 ELEC-6.3.5 CATEGORY- I Makes:Schneider/Kirloskar/Voltamp/ Esennar/ Toshiba/ KPEL/
Powertech /SSE
279 ELEC-6.3.5 A CATEGORY- II Makes:THOTA
280 ELEC-6.3.5 B CATEGORY- I Make:Schneider/Kirloskar/Voltamp/ Esennar/ Toshiba/ KPEL/
Powertech /SSE
281 ELEC-6.3.5 CATEGORY- II Make:THOTA
C
282 ELEC-6.3.6 …… Make:ABB/ALSTOM/SEIMENS/Crompton/Kirloskar/Voltamp/
Esennar
283 ELEC-6.3.7 …… Make:ABB/ALSTOM/SEIMENS/Crompton/Kirloskar/Voltamp/
Esennar
6.6 LIGHTENING PROTECTIVE SYSTEM
Advanced LPS
284 ELEC-6.6.1 a …… Make : THUNDERGUARD(EARTHPLUS)/ KALRE/ NIMBUS /
FOREND
285 ELEC-6.6.1 b …… Make : THUNDERGUARD(EARTHPLUS)/ KALRE/ NIMBUS /
FOREND
286 ELEC-6.6.1 c …… Make : THUNDERGUARD(EARTHPLUS)/ KALRE/ NIMBUS /
FOREND
287 ELEC-6.6.3 …… Make: EARTHPLUS (THUNDER GUARD) / NIMBUS / KALRE
/ FOREND
288 ELEC-6.6.5 …… Make: EARTHPLUS /CIRPROTEC /INDALAC / INGESCO
SECTION 7
7.0 LOCAL AREA NETWORK
289 ELEC-7.1.1 …… Makes: Systimax /AMP/ Panduit/ Siemond/ Molex/Legrand
290 ELEC-7.1.2 …… Makes: Systimax /AMP/ Panduit/ Siemond/ Molex/Legrand
291 ELEC-7.1.3 …… Makes: Systimax /AMP/ Panduit/ Siemond/ Molex/Legrand
292 ELEC-7.1.4 …… Makes: Systimax /AMP/ Panduit/ Siemond/ Molex/Legrand
293 ELEC-7.1.5 …… Makes: Systimax /Legrand/Molex/Krone /AMP
294 ELEC-7.1.6 …… Makes: Systimax/Legrand/Molex/Krone /AMP
295 ELEC-7.1.7 …… Makes: Systimax/Legrand/Molex/Krone /AMP
296 ELEC-7.1.8 …… Makes: Systimax/Legrand/Molex/Krone /AMP
297 ELEC-7.1.9 …… Makes: Systimax /Legrand/Molex/Panduit/Siemond/AMP
298 ELEC-7.1.10 …… Makes:Systimax /Legrand/Molex/Panduit/Siemond/AMP
299 ELEC-7.1.11 …… Makes: Systimax/Legrand/Molex/Panduit/Siemond/AM P
300 ELEC-7.1.12 …… Makes: Systimax /Legrand/Molex/Panduit/Siemond/AMP
301 ELEC-7.1.13 …… Makes: Systimax /Legrand/Molex/Panduit/Siemond/AMP
302 ELEC-7.1.14 …… Make: APW/HCL/Valrack/Netrack
303 ELEC-7.1.15 …… Make: APW/HCL/Valrack/Netrack
MANAGEBLE NET WORK SWITCHES
304 ELEC-7.1.16 …… Makes : Cisco Model SG350-28 or equivalent in
Juniper/Extreme
305 ELEC-7.1.17 …… Makes :Cisco Model SG300-52 or equivalent in
Juniper/Extreme
306 ELEC-7.1.18 …… Makes : Cisco Model:SG-350- 8PP or equivalent in
Juniper/Extreme
307 ELEC-7.1.19 …… Makes : Cisco Model:SG-350-28PP or equivalent in
Juniper/Extreme
308 ELEC-7.1.20 …… Makes :Cisco Model SG350-28SFP or equivalent in
Juniper/Extreme
309 ELEC-7.1.21 …… Makes: CISCO WS - C2960+24TC-L or equivalent in
JUNIPER/ EXTREME
310 ELEC-7.1.22 …… Makes: CISCO WS- C2960+48TC-L or equilent in
JUNIPER/EXTREME
311 ELEC-7.1.23 …… Make: CISCO-C2960+24PC-L or equilent in
JUNIPER/EXTREME
312 ELEC-7.1.24 …… Make: CISCO-C2960+48PST-L or equilent in
JUNIPER/EXTREME
313 ELEC-7.1.25 …… Make: CISCO WS - C2960X-24TS-L or equivalent in
JUNIPER/ EXTREME

288
314 ELEC-7.1.26 …… Make: CISCO WS - C2960X-48TS-L or equivalent in
JUNIPER/ EXTREME
315 ELEC-7.1.27 …… Make : Cisco Aironet 1815i or equivalent in Ruckus/Aruba
7.3 COMPUTERS,PRINTERS AND SCANNERS
316 ELEC-7.3.1 …… Model : HP ProDesk or its equivalent in Dell/Lenova
317 ELEC-7.3.2 …… Model : HP ProDesk or its equivalent in Dell/Lenova
318 ELEC-7.3.3 …… Make : HP LaserJet 1020 Plus Printer (OR) It's Equivalent in
Canon /Epson
319 ELEC-7.3.4 …… makes: Canon imageCLASS MF244dw /HP/Brother
DCPB7535DW or its equivalent
320 ELEC-7.3.5 …… Make : Brother ADS-2400N document scanner (OR) It's
Equivalent in Canon/HP
321 ELEC-7.3.6 …… Makes: Finolex / Delton / Surabi / Polycab
322 ELEC-7.3.7 …… Makes: Krone or its equivalent.
323 ELEC-7.3.8 …… Makes: Finolex / Delton / Surabi / Polycab.
324 ELEC-7.3.9 …… Makes: Finolex / Delton / Surabi / Polycab
325 ELEC-7.3.10 …… Makes: Finolex / Delton / Surabi / Polycab
326 ELEC-7.3.11 …… Makes: Finolex / Delton / Surabi / Polycab.
EPABX SYSTEM
7.4 SMALL SYSTEM
327 ELEC-7.4.1 …… Makes: NEC/ Alcatel /Avaya/Siemens
328 ELEC-7.4.2 …… Makes: NEC/ Alcatel /Avaya/Siemens
329 ELEC-7.4.3 …… Makes: NEC/ Alcatel /Avaya/Seimens
330 ELEC-7.4.4 …… Makes: NEC/ Alcatel /Avaya/Siemens
331 ELEC-7.4.5 …… Makes: NEC/ Alcatel /Avaya/Siemens
7.5 LARGE SYSTEM
332 ELEC-7.5.1 …… Makes: NEC/ Alcatel /Avaya/Siemens
333 ELEC-7.5.2 …… Makes: NEC/ Alcatel /Avaya/Siemens
334 ELEC-7.5.3 …… Makes: NEC/ Alcatel /Avaya/Siemens
335 ELEC-7.5.4 …… Makes: NEC/ Alcatel /Avaya/Siemens
336 ELEC-7.5.5 …… Makes: NEC/ Alcatel /Avaya/Siemens
8.1 MISCELLANEOUS ITEMS
NIL
9.1 WIRELESS FIRE ALARAM SYSTEM
337 ELEC-9.1.1 …… Makes: Cease Fire / Visonic / Honeywell
338 ELEC-9.1.2 …… Makes: Cease Fire / Visonic /Honeywell.
339 ELEC-9.1.3 …… Makes: Cease Fire / Visonic / Honeywell.
340 ELEC-9.1.4 …… Makes: Cease Fire / Visonic / Honeywell.
341 9.2 ADDRESSABLE - FIRE ALARM SYSTEM
342 ELEC-9.2.1 a CATEGORY- I Makes: Notifier / Edwards/Bosch
-f
343 ELEC-9.2.2 a CATEGORY- II Makes: Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo
-f
344 ELEC-9.2.3 CATEGORY- I Makes: Notifier / Edwards/Bosch
345 ELEC-9.2.4 CATEGORY- II Makes: Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo
346 ELEC-9.2.5 CATEGORY- I Makes: Notifier / Edwards/Bosch
347 ELEC-9.2.6 CATEGORY- II Makes: Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo
348 ELEC-9.2.7 CATEGORY- I Makes: Notifier / Edwards/Bosch
349 ELEC-9.2.8 CATEGORY- II Makes:Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo
350 ELEC-9.2.9 CATEGORY- I Makes: Notifier / Edwards/Bosch
351 ELEC-9.2.10 CATEGORY- II Makes: Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo.
352 ELEC-9.2.11 CATEGORY- I Makes: Notifier / Edwards/Bosch
353 ELEC-9.2.12 CATEGORY- II Makes:Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo.
354 ELEC-9.2.13 CATEGORY- I Makes: Notifier / Edwards/Bosch
355 ELEC-9.2.14 CATEGORY- II Makes: Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo.
356 ELEC-9.2.15 CATEGORY- I Makes: Notifier / Edwards/Bosch
357 ELEC-9.2.16 CATEGORY- II Makes:Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo.
358 ELEC-9.2.17 CATEGORY- I Makes: Notifier / Edwards/Bosch
359 ELEC-9.2.18 CATEGORY- II Makes:Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo .
360 ELEC-9.2.19 CATEGORY- I Makes: Notifier / Edwards/Bosch

289
361 ELEC-9.2.20 CATEGORY- II Makes:Siemens / Morley / Honeywell/ Ravel/Seaara/Apollo.
9.3 CONVENTIONAL - FIRE ALARM SYSTEM
362 ELEC-9.3.1 …… Makes: System Censor / Ravel/Vertex
363 ELEC-9.3.2 …… Makes: Makes: System Censor / Ravel/Vertex
364 ELEC-9.3.3 …… Makes: System Censor / Ravel/Vertex
365 ELEC-9.3.4 …… Makes: System Censor / Ravel/Vertex
366 ELEC-9.3.5 …… Makes: System Censor / Ravel/Vertex/Apollo.
367 ELEC-9.3.6 …… Makes: Makes: System Censor / Ravel/Vertex
368 ELEC-9.3.7 …… Makes: System Censor / Ravel/Vertex
369 ELEC-9.3.8 …… Makes: System Censor / Ravel/Vertex
9.4 POWDER BASED FIRE EXTINGUISHERS
370 ELEC-9.4.1 CATEGORY- I Makes : Cease Fire / Minimax
371 ELEC-9.4.2 CATEGORY- II Makes : Safex / Kenex / Bharat / Reliance/NewTech/Kartar
372 ELEC-9.4.3 CATEGORY- I Makes : Cease Fire / Minimax
373 ELEC-9.4.4 CATEGORY- II Makes : Safex / Kenex / Bharat / Reliance/NewTech/Kartar
374 ELEC-9.4.5 CATEGORY- I Makes : Cease Fire / Minimax
375 ELEC-9.4.6 CATEGORY- II Makes : Safex / Kenex / Bharat / Reliance/NewTech/Kartar
376 ELEC-9.4.7 CATEGORY- I Makes : Cease Fire / Minimax
377 ELEC-9.4.8 CATEGORY- II Makes : Safex / Kenex / Bharat / Reliance/NewTech/Kartar
CLEAN AGENT FIRE EXTINGUISHERS
378 ELEC-9.4.9 CATEGORY- I Makes : Cease Fire / Minimax
379 ELEC-9.4.10 CATEGORY- II Makes : Safex / Kenex / Bharat / Reliance/NewTech
380 ELEC-9.4.11 CATEGORY- I Makes : Cease Fire / Minimax
381 ELEC-9.4.12 CATEGORY- II Makes : Safex / Kenex / Bharat / Reliance/NewTech
382 ELEC-9.4.13 CATEGORY- I Makes : Cease Fire / Minimax
383 ELEC-9.4.14 CATEGORY- II Makes : Safex / Kenex / Bharat / Reliance/NewTech/Kartar
384 ELEC-9.4.15 …… Makes: Cease Fire or its equivalent make Model-1ES01
AEROSOL GENERATION SYSTEM
(An alternative to water based sprinkler system)
385 ELEC-9.4.19 …… Makes: SEAARA/AGS/SALAMANDRA
386 ELEC-9.4.20 …… Makes: SEAARA/AGS/SALAMANDRA
387 ELEC-9.4.21 …… Makes: SEAARA/AGS/SALAMANDRA
388 ELEC-9.4.22 …… Makes: SEAARA/AGS/SALAMANDRA
389 ELEC-9.4.23 …… Makes: SEAARA/AGS/SALAMANDRA
390 ELEC-9.4.24 …… Makes: SEAARA/AGS/SALAMANDRA
391 ELEC-9.4.26 …… Makes: SEAARA/AGS/SALAMANDRA
392 ELEC-9.4.27 …… Makes: SEAARA/AGS/SALAMANDRA
9.5 FIRE HYDRANT AND SPRINKLER SYSTEM
ELECTRIC DRIVEN MAIN FIRE PUMPS(SPLIT CASE)
393 ELEC-9.5.1 …… Makes of Pumps: Kirloskar / Mather&Platt. Makes of Motors:
Siemens/ ABB/ Kirloskar
394 ELEC-9.5.2 …… Makes of Pumps: Kirloskar / Mather&Platt. Makes of Motors:
Siemens/ ABB/ Kirloskar
395 ELEC-9.5.3 …… Makes of Pumps: Kirloskar / Mather&Platt. Makes of Motors:
Siemens/ ABB/ Kirloskar
396 ELEC-9.5.4 …… Makes of Pumps: Kirloskar / Mather&Platt. Makes of Motors:
Siemens/ ABB/ Kirloskar
397 ELEC-9.5.5 …… Makes of Pumps: Kirloskar / Mather&Platt. Makes of Motors:
Siemens/ ABB/ Kirloskar
DIESEL ENGINE DRIVEN FIRE PUMPS
398 ELEC-9.5.6 …… Makes of Engines : Kirloskar / Cummins. Makes of Pumps :
Kirloskar / Mather&Platt
399 ELEC-9.5.7 …… Makes of Engines : Kirloskar / Cummins. Makes of Pumps :
Kirloskar / Mather&Platt
400 ELEC-9.5.8 …… Makes of Engines : Kirloskar / Cummins. Makes of Pumps :
Kirloskar / Mather&Platt
401 ELEC-9.5.9 …… Makes of Engines : Kirloskar / Cummins. Makes of Pumps :
Kirloskar / Mather&Platt
402 ELEC-9.5.10 …… Makes of Engines : Kirloskar / Cummins. Makes of Pumps :
Kirloskar / Mather&Platt
ELECTRIC DRIVEN MAIN FIRE PUMPS(END SUCTION)

290
403 ELEC-9.5.11 …… Makes of Pumps: Kirloskar / Mather&Platt. Makes of Motors:
Siemens/ ABB/ Kirloskar
404 ELEC 9.5.12 …… Makes of Pumps: Kirloskar / Mather&Platt. Makes of Motors:
Siemens/ ABB/ Kirloskar
405 ELEC 9.5.13 …… Makes of Pumps: Kirloskar / Mather&Platt. Makes of Motors:
Siemens/ ABB/ Kirloskar
DIESEL ENGINE DRIVEN MAIN FIRE PUMPS(END
SUCTION)
406 ELEC-9.5.14 …… Makes of Engines : Kirloskar / Cummins. Makes of Pumps :
Kirloskar / Mather&Platt
407 ELEC-9.5.15 …… Makes of Engines : Kirloskar / Cummins. Makes of Pumps :
Kirloskar / Mather&Platt
408 ELEC-9.5.16 …… Makes of Engines : Kirloskar / Cummins. Makes of Pumps :
Kirloskar / Mather&Platt
JOCKEY PUMPS
409 ELEC-9.5.17 …… Makes of Pumps : Kirloskar / Mather&Platt. Makes of Motors :
Siemens/ ABB/ Kirloskar
410 ELEC-9.5.18 …… Makes of Pumps : Kirloskar / Mather&Platt. Makes of Motors :
Siemens/ ABB/ Kirloskar
411 ELEC-9.5.19 …… Makes of Pumps : Kirloskar / Mather&Platt. Makes of Motors :
Siemens/ ABB/ Kirloskar
BOOSTER PUMPS
412 ELEC-9.5.20 …… Makes of Pumps : Kirloskar / Mather&Platt. Makes of Motors :
Siemens/ ABB/ Kirloskar
413 ELEC-9.5.21 …… Makes : Kirloskar
414 ELEC-9.5.22 …… Makes : Kirloskar
415 ELEC-9.5.23 …… Makes : Kirloskar
CONTROL PANELS
416 ELEC-9.5.24 …… Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/
Siemens-3VL / Hager-h3/C&S -Winbreak2Makes of Meters :
Schneider (Conzerve) / L&T / Elmeasure / Siemens
417 ELEC-9.5.25 …… Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/
Siemens-3VL / Hager-h3/C&S -Winbreak2
Makes of Meters : Schneider (Conzerve) / L&T / Elmeasure /
Siemens
418 ELEC-9.5.26 …… Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/
Siemens-3VL / Hager-h3/C&S -Winbreak2
Makes of Meters : Schneider (Conzerve) / L&T / Elmeasure /
Siemens
419 ELEC-9.5.27 …… Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/
Siemens-3VL / Hager-h3/C&S -Winbreak2
Makes of Meters : Schneider (Conzerve) / L&T / Elmeasure /
Siemens
420 ELEC-9.5.28 …… Makes: L&T- D shine / Schneider-NS NSX/Legrand -DP X3/
Siemens-3VL / Hager-h3/C&S -Winbreak2
Makes of Meters : Schneider (Conzerve) / L&T / Elmeasure /
Siemens
421 ELEC-9.5.29 …… Makes of MCCBs : L&T / Siemens / Legrand / Schneider / ABB
/ Hager
Makes of Meters : Schneider (Conzerve) / L&T / Elmeasure /
Siemens
MS PIPES
422 ELEC-9.5.30 …… Makes: Jindal / Hissar / Tata pipes/Prakash Surya
423 ELEC-9.5.31 …… Makes: Newage/ Winco/ Padmini / Safex/Minimax/
Newtech/Honeywell/Kartar
424 ELEC-9.5.32 …… Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto /
SANT/NEU-G/Honeywell//Kartar
425 ELEC-9.5.33 …… Makes: BDK / NEU-G / Leader/ Zolotto /
SANT/Honeywell//Kartar
426 ELEC-9.5.34 …… Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto
/SANT/NEU-G/Honeywell//Kartar
427 ELEC-9.5.35 …… Make: NEU-G/Zolotto/Padmini/SANT/Honeywell/Kartar
428 ELEC-9.5.36 …… Makes: Newage/ Winco/ Padmini / Safex /

291
Minimax/NewTech/Honeywell/Kartar
429 ELEC-9.5.37 …… Makes: Newage/ Winco/ Padmini / Safex /
Minimax/NewTech/Honeywell/Kartar
430 ELEC-9.5.38 …… Makes: Leader / Zolotto/SANT/Honeywell/Kartar
431 ELEC-9.5.39 …… a) 36.6 Mtr Long 20mm (Nominal internal) dia water hose
Thermoplastic / Textile reinforced / Rubber braided /
Polypropylene Type - 2 as per IS:12585
Makes: Reliance/ Newage/
Safex/NewTech/Winco/Minimax/Kartar
b) 20mm (Nominal internal) dia gun metal ball/gate valve and
nozzle. Makes:NEU-G/SANT / Safex/Kartar.
432 ELEC-9.5.40 …… makes:Minimax/Safex/Newage/Winco
/Padmini/NewTech/Kartar
433 ELEC-9.5.41 …… Makes: Newage/ Winco/ Padmini / Safex /
a-b Minimax/NewTech/Kartar.
434 ELEC-9.5.42 …… . Makes: Newage/ Winco/ Padmini / Safex /
Minimax/NewTech/Honeywell/Kartar
435 ELEC-9.5.43 …… Makes: Newage/ Winco/ Padmini / Safex /
Minimax/NewTech/Honeywell/Kartar
436 ELEC-9.5.45 …… Makes: HD / TYCO / VIKING / NEWAGE/ SHARP /
SAFEX/Kartar
437 ELEC-9.5.46 …… Makes: HD / TYCO / VIKING / NEWAGE/ SHARP /
SAFEX/Kartar
438 ELEC-9.5.47 …… Makes : Danfoss / Indfoss /Systemsensor/Honeywell
439 ELEC-9.5.48 …… Makes : System Sensor / Switzer/Honeywell
440 ELEC-9.5.49 …… Makes : System Sensor / Switzer/Honeywell
441 ELEC-9.5.50 …… MAKES: HGURU / FIEBIG
442 ELEC-9.5.51 …… Makes : Zoloto / Leader / SANT/NEU- G/Kartar
443 ELEC-9.5.52 …… Makes : Zoloto / Leader / SANT/NEU- G/Kartar
444 ELEC-9.5.53 …… Makes : Zoloto / Leader / SANT/Kartar
445 ELEC-9.5.54 …… Makes : Tyko/Newage/HD/Kartar
446 ELEC-9.5.55 …… Makes : HD / TYCO / NEWAGE
447 ELEC-9.5.56 …… Makes:Normex /SANT/Kartar
448 ELEC-9.5.58 …… . Make:IWL(PIPE KOT) or its equivalent
449 ELEC-9.5.60 …… 1) DOL Starter Make C&S/ Crompton / L&T /KSP/
Siemens/BCH
2) Volt meter Make:Conzerve/Elmeasure/ Meco/ HPL/L&T/
Socomec
3) AmmeterMake: Conzerve/Elmeasure/Meco/HPL/ L&T/
Schneider/AE/ Socomec
4) selector switch
Make: L&T / C&S/ Salzer/HPL
5) Single Phase Preventor Makes: L&T / Minilec / Powertec. -
1No.
6) capacitor Makes: L&T / Siemens / Schneider /
Epcos/Havells.
7) MPCB (Motor Protection Circuit Breaker) Makes: L&T- D
shine / Schneider-NS NSX/Legrand -DP X3/ Siemens-3VL.
8) ON/OFF/TRIP push button actuators and integral contact
block of dia. 22.5 mm
i Make:Seimens/ ABB/ Schneider/ L&T/ C&S/HPL
9) power contactor
Make: Seimens/ABB/ Schneider/L&T/C&S/HPL/Havells - 3
pole, 35-40A AC3 Rating, Contactor
10) thermal over load relay
Make:Seimens/ABB/Schneider/L&T/C&S/HPL/Havells - 1 No
11)Current Transformer Make: Kappa/L&T/ Seimens/ C&S/
Schneider - 3 No
450 ELEC-9.5.61 …… Makes: Newage/ Winco/ Padmini / Safex /
Minimax/NewTech/Honeywell/ Kartar.
451 ELEC-9.5.62 …… Makes: HD / TYCO / VIKING / NEWAGE/ SHARP / SAFEX/
KARTAR

292
452 ELEC-9.5.63 …… Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto
/SANT/NEUG/Honeywell/ Kartar
453 ELEC-9.5.64 …… Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto /
a to e SANT/Honeywell/ Kartar
454 ELEC-9.5.65 …… Makes: Audco / Kirloskar / BDK / H-Shankar / Leader/ Zolotto /
SANT/Honeywell/ Kartar
455 ELEC-9.5.66 …… Makes: HD / TYCO / VIKING / NEWAGE/ SHARP / SAFEX
456 ELEC-9.5.67 …… . Makes: HD / TYCO / VIKING / NEWAGE/ SHARP / SAFEX
10.1 GENERATORS SPECIFICATION
457 ELEC-10.1.1 …… Engine Makes:Cummins/Koel Green/Sterling/ mahindra/Elmot
a-e Power Gen/Ashok Leyland/Greaves
Alternator Make:Stamford/ Kirloskar/
CromptonGreaves/Leroysomer
458 ELEC-10.1.1 …… Engine Makes:Caterpillar/Cummins/Koel
f-j Green/Mahindra/Elmot power Gen/Ashok Leyland/Greaves
Alternator Make:Leroy somer/Crompton Greaves/Stamford
459 ELEC-10.1.1 …… Engine Makes:Caterpillar/Perkins/Cummins/Greaves
k- p Alternator Make:Leroy somer/Crompton Greaves/Stamford
11.1 INVERTERS and ONLINE UPS SYSTEMS
460 ELEC-11.1.1 …… Makes: Exide / Amar Raja / Samhitha/ Microtek
461 ELEC-11.1.2 …… Makes: Numeric/APC/Fuji Electric Consul Neowatt/Sakshham
/Emerson
462 ELEC-11.1.3 …… Makes: Numeric/APC/Fuji Electric Consul Neowatt/Sakshham
/Emerson
463 ELEC-11.1.4 …… Makes: Mitsubishi/ Socomec /Schiender(APC)/ Legrand/Fuji
Electric Consul Neowatt
464 ELEC-11.1.9 …… Makes: Quanta / Racket / Exide.
465 ELEC- …… Makes: Quanta / Racket / Exide.
11.1.10
466 ELEC- …… Makes: Quanta / Racket / Exide.
11.1.11
467 ELEC- …… Makes: Quanta / Racket / Exide.
11.1.12
468 ELEC- …… Makes: Quanta / Racket / Exide.
11.1.13
469 ELEC- …… Makes: Quanta / Racket / Exide.
11.1.14
470 ELEC- …… Makes: Quanta / Racket / Exide.
11.1.15
471 ELEC- …… Makes: Amar Raja (Power Zone) or Equivalent model of Exide
11.1.17 / Panasonic / Gotech.
13.1 LIFTS (New Installation)
472 ELEC-13.1.1 …… makes:Kone/Otis/Schindler/Mitsubishi/Johnson
473 ELEC-13.1.2 …… makes:Kone/Otis/Schindler/Mitsubishi/Johnson
474 ELEC-13.1.3 …… makes:Kone/Otis/Schindler/Mitsubishi /Johnson
475 ELEC-13.1.4 …… makes:Kone/Otis/Schindler/Mitsubishi /Johnson
476 ELEC-13.1.5 …… makes:Kone/Otis/Schindler/Mitsubishi /Johnson
477 ELEC-13.1.6 …… makes:Kone/Otis/Schindler/Mitsubishi /Johnson
478 ELEC-13.1.7 …… makes:Kone/Otis/Schindler/Mitsubishi /Johnson
479 ELEC-13.1.8 …… makes:Kone/Otis/Schindler/Mitsubishi /Johnson
480 ELEC-13.1.9 …… makes:Kone/Otis/Schindler/Mitsubishi /Johnson

293
GUIDELINES FOR ELECTRICAL WORKS

PREFACE

Electrical supply and installation are an important and essential part of Building Services. Right from initial
planning, design, selection of material, installation / method of construction; to testing, commissioning
and maintenance; every aspect is governed by statutory provisions referring various Standards and
Codes. All such norms are oriented to minimize risk, provide safe use, operation, functionality, and
convenience throughout service life.

Any lapse in any of the above aspect may lead to severe effects on human life and devastation of assets.
Occasions of electrical fires are increasing with the increasing use and electrical gadgets. Unfortunately,
still it is seen that Electrical Installation is given least importance. Qualities and safeties are compromised
out of connivance or lack of technical knowledge. Many times, electrical work gets executed through non-
qualified persons not having required knowledge and Permit in that regard. Such hired persons work on
labor basis to whom non- standard material is supplied without any base of ‘Design’. There is no
person to supervise quality and safety aspects, most of which remains ‘concealed’ as the work gets
completed.

In case of High-Rise buildings norms are more stringent. Fire hazard is more prominent risk factor as
evacuation in high-rise building is a challenging task. Part 3 section 7 of NEC gives special guidelines in this
regard.

The person who uses, operates electrical installation is not expected to know the real technical aspects of
design, material used, quality of work, adherence to safety, compliance with statutory provisions.
Under the circumstances it has become a need to set base line parameters. Plug the loopholes, get
the work done adhering to norms and standards and make someone responsible so that in case of any
lapse /mishap such person / agency can be made answerable.
Important Note:

1. SSR rates for Electrical items are purely for guidance of the officers in preparation of estimates vide
Para 113 of APPWD Code. Authority who prepares the estimate is, however responsible for proper rates as
envisaged in Para 45 of APPWD Code.

2. The rates published in the Buildings SoR 2021-22 are the ceiling rates only and the estimate
preparing authorities are responsible for the correctness and reasonableness of the rates and technical
specifications adopted in the estimates

The following guidelines /recommendations / mandates are basically given to execute work
of Electrical Installation.

1. ARCHITECTURAL / CIVIL WORK PROVISIONS RELATED TO ELECTRICAL INSTALLATION

1.1 Architectural Planning requirements:

At planning stage Architect shall discuss and consider requirements of Electrical Consultant /
Contractor in respect with site and location of construction and in respect with drawings of building
requirement of spaces, clearances, approach ways, raceways, shafts, recommended wall thickness,
required provisions for prevention from fire hazard likely to originate from electrical installation.

If proposed construction is within vicinity of existing over-headline, underground cable compliance with
Regulation 63 of CEA Safety Regulations shall be checked prior to commencement of any work on
site.

Architect shall incorporate following points in the drawings related to services as per the applicable
requirements.

1.1.1 Site Plan:

Site plan shall show existing overhead electrical lines / underground cables if any and proposed
construction within the boundaries of the area to be developed.

294
1.1.2 Routes and service entry points:

Architectural drawings shall clearly mark electrical service entry points, cable routes below ground,
through the building structure, so that detailing in electrical shop drawings will restrict the work within
specified route and no conflict shall occur with other building utility service. The drawings shall
specify required horizontal and vertical clearance to be maintained between other utility services.

1.1.3 Locations of Electrical Panels:

Locations and position for main and sub electrical panels shall be marked, and adequate space /
room shall be allocated considering dimensions of panel, clearance in front, side and back.
Consideration shall be given to space required for opening of the panel doors / racking out breakers,
and approach boundaries (Refer NEC Part1 / section 24 Electrical Safety), and accessibility. Floor
mounting panels shall preferably be located in separate Electrical Panel Rooms having outside
door opening, required fire rating (two hours if not specified) and ventilation arrangement.

NOTE – Special consideration shall be given to this point in case of High-Rise buildings.

1.1.4 Electrical meter rooms:

Meter rooms shall be separate. It shall be planned to have sufficient head room and clear space in front of
meters, control switches (at least 1m). Space on wall shall be sufficient to accommodate required number
of meters at suitable height so that readings can be taken without aid of any tackle. Also, the
switchgears shall be at least 0.5 m above floor level and within such height to have an easy access for
operation. The meter room shall be well ventilated, protected from external influences like sun, rain,
water seepages, entry of rodents. Location of meter room shall be suitably adjacent or nearest to cable
duct / shaft / vertical route of mains.

NOTE – Meterroomsshall not be located below staircaseswhere aboverequirements could


notbecomplied with.

1.1.5 Movement of heavy / bulky electrical equipment:

For installation of electrical equipment within building which is likely to be heavy / bulky in size or removing
it for maintenance, provision of adequate passages, stair ways or any alternate provision for its shifting /
movement shall be considered.

1.1.6 Shafts /ducts:

There shall be provision of shafts with required fire rating ( 2 hours if not mentioned specifically)
for vertical electrical distribution which shall preferably be adjacent to electrical panels. Shafts shall be
separate for electrical HT cables, LT power cables / bus-bar trucking and cable work of Extra Low
Voltage systems like telephones, security system, fire alarm, signaling, BMS or data networking etc. If
independent shaft is not possible, there shall be an arrangement for segregation in between, which shall
have required fire rating same as that of shaft. No other utility service shall run through these shafts.
Shafts shall be accessible at all levels with doors having fire rating as that of shaft and shall not open in
fire escape staircase. All shafts shall have fire prevention provision as per National Building Code and fire
safety requirements of local statutory authorities.

NOTE- As per CEA Reg.36 provision in respect of independent electrical service shaft is mandatory
for all buildings above 15m height (High-Rise buildings).

1.1.7 Interior design and Electrical Layouts:

It is recommended to prepare interior layouts so as to plan electrical points, locations of switch


boards to suite the aesthetics, functionality as well as for comfort and ease of operation.
1.1.8 Aesthetics and Electrical Safety

To avoid conflicts between Architect from perspective of aesthetic and person executing electrical
installation work from the point of view of safety requirements of electrical work, convenience and ease
of installation and further maintenance depending on type of wiring (concealed / surface / hybrid),
location of distribution boxes, requirement of under-floor truncking / false flooring / false ceiling, wall
partitions and openings to enter into / work within as per the need. These points shall be decided at
planning stage.

295
1.1.9 Illumination

Within interior work number, type, size, and location of luminaries shall be decided and agreed upon
mutually between Architect and Electrical Agency, considering technical parameters of lux level, CCT, heat
dissipation, accessibility and maintainability.

1.1.10 Ceiling Fans

Location of ceiling fans shall suite recommended minimum clearance between ceiling / false ceiling
and fan blade (225mm), floor level and fan blade(2400mm).Sweep of fan blades shall not obstruct
light source. Location and size of fan shall also suite utility from the point of view of users and aesthetically
match with false ceiling design.

NOTE: Sometimes due to afterthought provision of false ceiling, it creates problems affecting
required clearances. Under some cases, replacement of down rod with suitable length may solve
problem but in case of limited ceiling height it is not possible.

1.1.11 Exhaust fans

Wherever provision of exhaust fans is there, cross ventilation shall be considered to allow sufficient fresh air
to enter into particular envelop, e.g. For toilets where
Exhaust fans are proposed, door under cuts or louvers preferably at lower level for cross ventilation shall
be provided.

NOTE: Non provision of entry for fresh air creates negative pressure within the envelope
increasing load on exhaust fan resulting into heating and subsequent failure.

1.1.12 Earthing

Location of earthing pits shall be shown on drawings so that those shall always remain open and
accessible for testing and maintenance throughout the service period.

1.1.13 Restricted Access

Areas requiring restricted access to designated person, authorized to carry out electrical work therein shall
be provided with necessary arrangements.

1.1.14 Sub stations / Generators / Battery rooms

Location of required civil structure shall be considered in advance with required height of room, door
openings, firefighting system, ventilation etc.

1.2 Civil Planning and Constructional Requirements

It is important to plan activities of civil construction and electrical works in detail on bar chart or similar
tools available in project planning. The bar chart shall be updated and coordination be monitored to avoid
conflicts, breakages and reworking. Following points give general guidelines.

1.2.1 Fire rating

The electrical panel rooms, doors, segregation arrangement within shaft shall have fire rating of 2
hours or as per requirements mentioned under NBC, Central Electricity Authority (measures related
to Safety and Electric Supply) Regulations,2010 and further amendments.

1.2.2 Shafts / Ducts /Chambers

Design and location of cable ducts, shafts, chambers, their covers, and entry points, shall be as
per shop drawings provided by electrical agency and shall be in consultation with, considering further
aspects of maintenance / repairs / replacement . Size of chambers shall be in consideration with
bending radii of cables. At every flooring level, there shall be a provision to seal these shafts, so that
in case of fire, it shall not spread, or smoke shall not pass from one floor to other.

1.2.3 Openings and covers

296
Manholes / opening of chambers shall not be less than 650mm x 550mm or 650mm India., where
opening is intended for entry of person. C overs of manholes, chambers shall bear sufficient strength
to with stand loads likely to be imposed on the structure. Covers shall be marked with the name of the
service.
Openings / covers of Junction boxes / draw-in boxes / accessories in conduit systems with inspection
openings shall always be accessible.

1.2.4 Enclosures for underground cables

Pipes to be used for cable as enclosures shall be of required diameter so that cable can pass through or
removed from easily and have sufficient mechanical strength and shall be erected at required depth to
suite requirements of IS 1255.

1.2.5 Wall thickness

Walls shall be of sufficient thickness to accommodate concealed boxes /switchboards / distribution


boxes. So thatinstallation of boxes will not affect strength of wall. Additional strengthening shall be
considered if necessary.

NOTE : Depth of box may be 60 mm or vary depending on manufacturer’s design.Under


circumstances in 4”/100 mm wall it is not possible to accommodate these boxes back-to-back.
Staggering may solve problem to certain extent.

1.2.6 Structural strength


In Wiring Installation where Cable Ladder, Tray system is used for cable management, its
structure along with the load of cables which it is going to support, is likely to impose load on the
primary structure of building. This situation occurs when supportsof this system are fixed on building
structure. For this building structure shall have capacity to bare the load.

At some locations there are chances of conduits getting crowded endangering structural strength due
to number of circuits entering / passing out from the particular DB / panel. This situation may occurin
beam, slab, and wall. If such situation is unavoidable necessary measures may be required to be taken to
retain structural strength.
1.2.7 Sleeves / core cutting
As far as possible sleeves shall be got erected for entry of wires / cables through wall, flooring, RCC
structure during construction to avoid core cutting, damages and reworking at finishing stage. Sometimes
core cuttings may berequired whichshall be done with the consent of structural engineer and under
supervision of civil engineer.

1.2.8 Water leakages / seepages

Design shall take into consideration possible seepages, leakages, accumulation, and ground in-surge of
water, which is hazardous to electrical installation. Required provisions shall be made at such locations to
prevent and work shall be executed with due care.

1.2.9 Bathrooms /washrooms

Within bathrooms / washrooms, location of showers, faucets shall be such that during use, water shall not
splash on switch boards / electrical outlets / fittings.

1.2.10 Tandems in Flat Slab post tension structures

For flat slab post tension structure’s locations of tandems marking shall be made to avoid puncture of /
damage to tandems during electrical construction activity.

1.2.11 Earthing

Any construction work, including excavation, subsequent to construction of earthing electrode/s ; it shall
not disturb / damage any part of earthing system. Any civil work on construction site shall not cause
cover-up / concealing of any portion of electrical earthing system without notice and consent of
person In- Charge of electrical work.

1.2.12 Sub stations / Generators / Batteries

Trenches, ventilation, approach roads shall be provided as per necessity.

297
2. ELECTRICAL PROVISIONS

2.1 Statutory Obligations – Appointment of Licensed Electrical Contractor

Reg .29(1) shall be strictly followed by the Developer and work shall be got done through Licensed
Electrical Contractorwho shall submit Test Report of the work carried-out by him.

Developer may take undertaking from the Licensed Electrical Contractor, who shall be responsible to
do the work through the qualified workmen having required permit in that regard. He shall also see that
the material to be used, work and workmanship shall conform to respective norms, standards, and
Regulations.

NOTE–All hiddenwork shall be checked for conformity with thestandards prior to get it concealed,
shall be certified by the contractor.

2.2 Statutory Obligations–Approvals /Permissions / Licenses

Required approvals shall be taken as per related Rules and Regulations mentioned below prior to the
commissioning and handing over the installation for beneficial use.

a) Central Electricity Authority (measures related to safety and electric supply)


Regulations 2010 and amendments 2015, 2018
b) Reg. 32 – Generator Inspection and approval for commissioning.
c) Reg. 36 – Multi-storied building (height above 15m): inspection and NOC for
commencement of supply
d) Reg. 43 –Transformer sub-station or any installation above 660V : inspection and
approval before commencement of supply

See Annexure C of above regulations for extract of Regulations.

2.3 Material

Material used for Electrical Installation shall conform to the respective Indian standards or
International standards where relevant Indian Standards are not available.
Technical Specification of materialshall strictly adhere to the design, based on load, use, external
influences and safety.

2.4 Wiring Installation

Electrical Installation shall conform to provisions from related sections of National Electrical Code
(NEC) and National Building Code (NBC). See Annexure A for minimum / basic requirementsfrom the
point of view of Safety and functionality.

2.5 Transformer sub-station

Transformer sub-station providing supply to the building if located within building shall either use dry type
transformer or a transformer filled with Synthetic Ester. Transformer filled with Natural ester shall be used
only if transformeris sealed (without breather). For Transformer installed in separate roomdetached from
building structure 7.5m away Mineral oil may be allowed.

2.6 Generator standby supply

For every high-rise building there must be a provision of generator supply as a standby arrangement
which shall be of adequate capacity to cater load of all emergency systems for required time.
Location and system of supply shall be such that functioning, and purpose of Generator will not be
affected due to emergency like fire in building. If fire authority requires standby supply arrangementfor fire-
fighting system also, provision of generators shall be made accordingly.

2.7 Handing over Documents

298
It shall be a part of obligation on the developer to handover the documents belonging to the
prospective owner for his information and which he will need him for reference and maintain as a record.

2.8 MCBs

For lighting circuit 6A MCB and for powercircuit of powerpoint 16A MCB shall be used. For lighting circuits
MCBs of B series may beused. For independent circuit of plug points C series MCB shall be provided.
Circuits providingsupply for appliances like Air-Conditioner / water-pump shall be provided MCBs of ‘C
’series. AC above1.5 TR may beprovided with MCB of 20 /25 A rating.

2.9 RCDs

Complete electrical installation must be protected against electrical shock by provision of Residual
Current Device (also referred as ELCB/RCCB) having sensitivity of 30mA. RCDs may be provided more
than one at suitable locations, to retain supply redundancy. In three phaseDBs per phase protection
maybe provided. For installation having load 10kw and above, it is also recommended to provide RCD
of300mA sensitivity at the source / point of supply to provide protection against Fire due to leakage
currents.

2.10 Main switchgears

Depending on load provision of MCCBs, Circuit breakers shall be made with precise rating of overload,
short-circuits etc.

3. Provision in respect of High-Rise Building

3.1 Supply isolation during Emergency Sub Regulation (3) of CEA Regulation No.36 provides for
arrangement to completely isolate the supply at the time of emergency. It shall be interpreted as below:

3.2 The provision of a device to isolate complete supply, also called Fireman’s Switch, is aimed at
restricting further danger of short circuits due to fire and spread of fire and shock hazard, restriction on
use of Lifts and any other activity running on electrical supply which may aggravate the situation.
However supply to emergency services like rescue operation; Fire- Fighting shall not get affected with the
operation of this control.

3.3 Suitable arrangement shall be done at the point of supply to separate supply of emergency
services make arrangements to identify and mark with instructions

CEA (Measures related to Safety andElectric Supply) Regulations 2010 made under section 53 read
with section 177 of Electrical Act2003 Regulation29 (1):

No electrical installation work, including additions, alterations, repairs and adjustments to existing
installations, except such replacement of lamps fans, fuses, switches, domestic appliances of voltage not
exceeding 250V and fittings as in no way alters its capacity or character, shall be carried out upon the
premises of or on behalf of any consumer, supplier, owner or occupier for the purpose of supply to
such consumer, supplier, owner or occupier except by an Electrical Contractor licensed in this behalf
by the State Government and under the direct supervision of a person holding a certificate of
competency and by a person holding a permit issued or recognized by the State Government.

3.4 Regulation12 (1):

All electric supply lines and apparatus shall be of sufficient rating for power, insulation and
estimated fault current and of sufficient mechanical strength, for the duty cycle which they may be
required to perform under the environmental conditions of installation, and shall be constructed,
installed, protected, worked, and maintained in such a manner as to ensure safety of human beings,
animals and property.

3.5 Regulation12 (2):

Save as otherwise provided in these regulations, the relevant code of practice of The Bureau of Indian
Standards or National Electrical Code, if any, may be followed to carry out the purposes of this regulation
and in the event of any inconsistency, the provisions of these regulations shall prevail.

3.6 Regulation12 (3):

299
The material and apparatus used shall conform to the relevant specifications of the Bureau of Indian
Standards or International Electro-Technical Commission where such specifications have already been
laid down.

3.7 Regulation12 (4):

All electrical equipment shall be installed above the Mean Sea level (MSL) as declared by local
Municipal Authorities and where such equipment is to be installed in the basement, consumer shall
ensure that the design of the basement should be such that there is no seepage or leakage or logging of
water in the basement.

3.8 Regulation 3phases Provisions for supply and use of electricityin multistoried building more than15
meters in height: Regulation36 (3) .The supplier or owner of the installation shall provide at the
point of commencement of supply a suitable isolating device with cut-out or breaker to operate on all
phases except neutral in the 3-phase,4-wire circuit and fixed in a conspicuous position at not more
than1.70meters above the ground so as to completely isolate the supply to the building in case of
emergency.
a) Color Coding for Phase / Live – Red / yellow / Blue
b) Color Coding for Neutral – Black
c) Color Coding for Earth – Green
d) For light / bell wiring shall be two wire system .
e) For ceiling fan / exhaust fan / Separate socket wiring shall be three wire system .

Circuit main for switch boards:-

Circuit main for switch board shall be 3 runs of 2.5sq.mm copper cable i.e for phase, neutral and
Earth. That is from DB to switch board.

Circuit Main for 16A socket :-

Circuit mains for 16A sockets shall be 3 runs 4.0sq.mm from DB to 16A socket. Phase, neutral and
earth conductor are equal in size (i.e sq.mm).
Circuit Main for AC socket:-

Circuit mains for AC socket shall be 3 Runs of 6.0sq.mm from DB to AC socket. Phase, neutral and
earth conductor are equal in size (i.e sq.mm).

Note: Power circuit rated more than 1KW, size as per calculations.

Capacity of Circuits:

I Lighting circuits shall feed light / fan / call bell points. Each circuit shall not have more than 800W
Connectedload or more than 10 points. In case of LED lights, where load per point may be less,
number of points may be suitably increased.

II Power circuit in NRB will have only one outlet per circuit.

III Each power circuit in residential buildings can feed following outlets.
Not more than 2 No’s 16A socket outlets.

Not more than 4 No’s 6A/ 10A socket outlets.

c) Not more than 1 No 16A & 2Nos 6A out lets.

IV. Load more than 1 KW shall be controlled by suitable rated MCB, and cable size shall be decided as
per the load calculations and length of circuit mains.

V. Load shall be distributed equally among the three phases.

300
GOVERNMENT OF ANDHRA PRADESH
ABSTRACT

Mines & Minerals – Amendment to the Rule 10 of the Andhra Pradesh Minor
Mineral Concession Rules, 1966 - Orders – Issued.
---------------------------------------------------------------------------------------
INDUSTRIES AND COMMERCE (M.II) DEPARTMENT

G.O.MS.No. 11 Dated: 11-02-2020


Read the following:

1. G.O.Ms.No.198, Industries & Commerce (M.I) Dept., dt:13.08.2009.


2. GSR No.423 (E), dt:10.02.2015 from the Ministry of Mines,
Govt. of India, New Delhi.
3. G.O.Ms.No.100, Industries & Commerce (M.II) Dept., dt:31.10.2015.
4. G.O.Ms.No.105, Industries & Commerce (M.II) Dept., dt:13.11.2015.
5. G.O.Ms.No.38, Industries & Commerce (M.II) Dept., dt:17.03.2016.
6. G.O.Ms.No.156, Industries & Commerce (M.II) Dept., dt:03.11.2016.
7. G.O.Ms.No.131, Industries & Commerce (M.II) Dept., dt:04.10.2017.
8. G.O.Ms.No.18, Industries & Commerce (M.II) Dept., dt:29.01.2018.
9. G.O.Ms.No.28, Industries & Commerce (M.II) Dept., dt:17.04.2018.
10.G.O.Ms.No.49, Industries & Commerce (M.II) Dept., dt:21.02.2019.
11.Proposal from the Director of Mines & Geology, vide e-fileNo:INC04-
17021(34)/1/2019-PLANNING SEC-DMGreceived by the Government on
dt. 11.12.2019.

***
O R D E R:

After careful examination of the proposal received from the Director of


Mines & Geology, Andhra Pradesh, Ibrahimpatnam in the letter 11th read above,
the Government hereby decided to amend the Rule 10 of Andhra Pradesh Minor
Mineral Concession Rules, 1966 for enhancing the existing Seigniorage fee and
Dead Rent in respect of Minor Minerals.

2. The following notification will be published in the Extra-ordinary issue of the


Andhra Pradesh Gazette, dated:11.02.2020.

NOTIFICATION

In exercise of the powers conferred by sub-section (1) of section 15 of the


Mines & Minerals (Development and Regulation) Act, 1957 (Central Act 67 of
1957), the Governor of Andhra Pradesh hereby makes the following
amendments to the Andhra Pradesh Minor Mineral Concession Rules, 1966
issued in G.O.Ms.No.1172, Industries and Commerce Department, dated.
04.09.1967 and subsequent amended from time to time.

AMENDMENT

In the said rules, under Rule 10 for Schedules I and II, the following shall be
substituted, namely

Page 1 of 8
“SCHEDULE-I”
RATES OF SEIGNIORAGE FEE

Rate of Seigniorage Fee


Sl. No. Name of the Minor Mineral Units
(in Rupees)
Rs. 145
1 Agate M.T. (Rupees One Hundred and
Forty Five)
Rs. 75
2 Ball Clay M.T.
(Rupees Seventy Five)
3 Barytes
Rs. 480
i. Grey Colour - A Grade M.T. (Rupees Four Hundred and
Eighty)
Rs. 355
ii. Grey Colour - B Grade M.T. (Rupees Three hundred
and Fifty Five)
Rs. 220
iii. Grey Colour - C + D +
M.T. (Rupees Two Hundred and
Waste Grade
Twenty)
Rs. 1,100
iv. White Colour M.T. (Rupees One Thousand
and One hundred)
v. Off Colour Other than Rs. 500
M.T.
Grey (Rupees Five Hundred)
Rs. 90/60
4 Building Stone M3/M.T.
(Rupees Ninety / Sixty)
Rs. 90
5 Calcareous Sand M.T.
(Rupees Ninety)
Rs. 90
6 Calcite M.T.
(Rupees Ninety)
Rs. 90/60
7 Chalcedony Pebbles M3/M.T.
(Rupees Ninety / Sixty)
Rs. 95
8 Chalk M.T.
(Rupees Ninety Five)
Rs. 60
9 China Clay M.T.
(Rupees Sixty)
Rs. 60
10 Clay (Others) M.T.
(Rupees Sixty)
Rs. 120
11 Corundum M.T. (Rupees One Hundred and
Twenty)
Rs. 415
12 Diaspore M.T. (Rupees Four hundred and
fifteen)
Rs.135
Dimensional Stone used for
13 M.T. (Rupees One hundred and
Kerbs& Cubes
Thirty Five)
Rs. 100
14 Dolomite M.T.
(Rupees One Hundred)
Page 2 of 8
Rs. 60
15 Dunite or Pyroxinite M.T.
(Rupees Sixty)
Rs. 100
16 Feldspar M.T.
(Rupees One hundred)
Rs. 130
17 Felsite M.T. (Rupees One hundred and
thirty)
Rs. 60
18 Fireclay M.T.
(Rupees Sixty)
Rs. 180
19 Fullers Earth/ Bentonite M.T. (Rupees One Hundred and
Eighty)
Rs. 90
20 Fuschite Quartzite M.T.
(Rupees Ninety)
Granite useful for cutting
21
and polishing purpose

Super Mini
Gang Gang
270cm Below
Sawequal and Sawequal and
Item Unit X 150 cm & 75cm
above above
Below size size
300cmx180cm 270cmx150cm
size size
Rs.4600/ Rs.3680/ Rs.1550/
Rs.3450 /
Rs.1415 Rs.1130 Rs.480
Rs.1060
(Rs. Three (Rs. One
(Rs. Three
(Rs. Four thousand six thousand
Black Galaxy M3/ thousand four
thousand six hundred five hundred
Granite Variety MT hundred fifty/
hundred/Rs. eighty/Rs. One fifty/ Rs.
Rs. One
i. One thousand thousand one Four
thousand
four hundred hundred thirty) Hundred
sixty)
fifteen) eighty)
Rs.1150/
Rs.2875/
Rs.3450/ Rs.2700/ Rs.385
Rs.960
Rs.1150 Rs.900 (Rs. One
(Rs. Two
Black Granite (Rs. Three (Rs. Two thousand
M3/ thousand eight
ii. other than thousand four thousand one hundred
M.T. hundred
Galaxy variety fifty/Rs. One Seven fifty/ Rs.
seventy five/Rs.
thousand one hundred / Rs. Three
nine hundred
hundred fifty) Nine hundred) Hundred
sixty)
eighty five)
Colour Granite
Srikakulam Rs.1150/
Rs.3,450/ Rs.2,875/ Rs.2,700/
Blue, Moon Rs.420
Rs.1,255 Rs.1,045 Rs.980
white, River (Rs. One
(Rs. Three (Rs. Two (Rs. Two
white of thousand
M3/ thousand four thousand eight thousand
iii. Visakhapatnam one hundred
M.T. fifty/Rs. One hundred Seven
Dist., Leptinites fifty/ Rs.
thousand two seventy five/Rs. hundred / Rs.
of Coastal Four
hundred fifty One thousand Nine hundred
Dists., Black Hundred
five) forty five) and eighty)
pearl of twenty)
Prakasam and
Page 3 of 8
Guntur Dists.
Rs.1150/
Rs.2700/ Rs.2470/ Rs.2300 /
Rs.420
Rs.985 Rs.900 Rs.835
(Rs. One
(Rs. Two (Rs. Two (Rs. Two
Colour Granite thousand
M3/ thousand seven thousand four thousand
iv. of other one hundred
M.T. hundred/Rs. hundred three hundred
varieties fifty/ Rs.
Nine hundred seventy/Rs.Nine / Rs. Eight
Four
eighty five) hundred) hundred and
Hundred
thirty five)
twenty)
Rs.1925/ Rs.1650/ Rs.1375 /
Kuppam Grey Rs.1100/
Rs.700 Rs.600 Rs.500
Granite Rs.400
(Rs. One (Rs. One (Rs. One
available in (Rs. One
M3/ thousand nine thousand six thousand and
v. Santhipuram& thousand
M.T. hundred twenty hundred three hundred
Ramakuppam one hundred
five/Rs. Seven fifty/Rs. Six and seventy
mandals of / Rs. Four
hundred) hundred) five/ Rs. Five
Chittoor District Hundred)
hundred)
Rs.1925/ Rs.1650/ Rs.1375 /
Chittoor Rs.1100/
Rs.700 Rs.600 Rs.500
Colour Granit Rs.400
(Rs. One (Rs. One (Rs. One
e (Other than (Rs. One
M3/ thousand nine thousand six thousand
vi. Silver-waves, thousand
M.T. hundred twenty hundred three hundred
Madanapalli one hundred
five/Rs. Seven fifty/Rs. Six seventy five/
white and / Rs. Four
hundred) hundred) Rs. Five
Iscon white) Hundred )
hundred
Rs. 150
22 Gypsum M.T. (Rupees One Hundred and
Fifty)
Rs. 145
23 Jasper M.T. (Rupees One Hundred and
Forty Five)
Rs. 60
24 Kaolin M.T.
(Rupees Sixty)
25 Laterite
i. Dispatched for use in
Rs. 200
Alumina &Aluminium M.T.
(Rupees Two Hundred)
metal extraction
ii. For use other than
Alumina and Rs. 100
M.T.
Aluminium metal (Rupees One Hundred)
extraction and export
Rs. 90
26 Lime Kankar/ Limestone M.T.
(Rupees Ninety)
Rs. 120
27 Lime Shell M.T. (Rupees One Hundred and
Twenty)
Limestone Slabs:
28 Sq.Mt/ M.T. Rs. 10 (Rupees Ten) per
i. Color
Sq.Mtor Rs.120

Page 4 of 8
(Rupees One Hundred and
Sq.Mt/ M.T.
ii. White Twenty) per MT whichever
is higher
Rs. 6 (RupeesSix) per
Sq.Mtor Rs.110
Sq.Mt/ M.T.
iii. Black (Rupees One Hundred and
Ten) per MT whichever is
higher
Rs. 90/60
29 Manufactured Sand M3/M.T.
(Rupees Ninety / Sixty)
Rs. 300/120
30 Marble M3/M.T. (Rupees Three Hundred /
One Hundred and twenty)
31 Mica -
M.T. Rs. 2,000
i. Crude
(Rupees Two Thousand)
Rs. 750
M.T.
ii. Scrap (Rupees Seven Hundred
and Fifty)
Rs. 45/30
Morrum/ Gravel & Ordinary
32 M3/M.T. (Rupees Forty five /
Earth
Thirty)
Rs. 90
33 Mosaic Chips M.T.
(Rupees Ninety)
Rs. 60
34 Ochre M.T.
(Rupees Sixty)
Ordinary Clay, Silt and Brick Rs. 8,000
Earth used in the (Rupees Eight Thousand)
35
Manufacture of Bricks Per Kiln Per Annum for
including Mangalore Tiles Bricks and Tiles
Rs. 100/ Rs. 66
36 Ordinary Sand M3/M.T. (Rupees One Hundred/Rs.
Sixty Six)
Rs. 200
37 Pyrophillite M.T.
(Rupees Two Hundred)
Rs. 90
38 Quartz M.T.
(Rupees Ninety)
Rs. 90
39 Quartzite M.T.
(Rupees Ninety)
Rs. 35/ Rs. 25
40 Rehmati M3/M.T. (Rupees Thirty five/Twenty
five)
Rs. 90/60
41 Road Metal & Ballast M3/M.T.
(Rupees Ninety / Sixty)

Rs. 90/60
42 Rough Stone/ Boulders M3/M.T.
(Rupees Ninety / Sixty)
Rs. 100
43 Sand (Others) M.T.
(Rupees One Hundred)

Page 5 of 8
Rs. 180
44 Shale M.T. (Rupees One Hundred and
Eighty)
Rs. 90/60
45 Shingle M3/M.T.
(Rupees Ninety / Sixty)

Rs. 100
46 Silica Sand M.T.
(Rupees One Hundred)
Rs. 175
47 Slate M.T. (Rupees One hundred and
Seventy five)
48
Steatite or Talc or
Soapstone

M.T. Rs. 100


i. Filler Grade
(Rupees One Hundred)
Rs. 550
M.T.
ii. Other Grade (Rupees Five hundred and
Fifty)

SCHEDULE-II

RATES OF DEAD RENT

Rate of Dead Rent per


S.No Name of the Minor Mineral hectare per annum
(In Rupees)
Rs. 1,30,000/-
Black Galaxy Granite and Black
1 (Rs. One Lakh Thirty
Granite
Thousand)
Rs. 1,30,000/-
2 All Colour Granite varieties (Rs. One Lakh Thirty
Thousand)
Limestone other than classified as
major minerals used for lime
burning for Building construction
purposes, marble, boulders,
building stone including stone used
for Road Metal, Ballast, Rs. 65,000/-
3
Manufactured sand, concrete & (Rs. Sixty Five thousand)
other construction purpose, Shale,
Slate &Phyllites, Mosaic Chips,
Fullers Earth/Bentonite &
Dimensional Stone used for Cubes
and Kerbs
Gravel, Morrum, Ordinary Earth,
Shingle, Limestone Slabs used for
flooring purpose Limekankar, Rs. 52,000/-
4 ChalcedonyPebbles used in the (Rs. Fifty two
building purpose Limeshell for thousand)
burning used for building purpose
and Rehmati.
5 Barytes and Laterite Rs. 26,000/-
Page 6 of 8
(Rs. Twenty Six Thousand)
Agate, Corundum, Diaspore and Rs. 20,000/-
6
Fluorite (Rs. Twenty Thousand)
Rs. 15,000/-
7 Mica
(Rs. Fifteen Thousand)
All minor minerals which are not
Rs. 20,000/-
8 covered under Serial number 1 to
(Rs. Twenty Thousand)
7 above.

3. This order shall come in to force with immediate effect.

4. This order issues with the concurrence of Finance Department vide


their U.O. No. FMU0ASD(IC)/111/2019-FMU-IIEIC, dt.09.01.2020 (Computer No.1063684).

[BY ORDER AND IN THE NAME OF THE GOVERNOR OF ANDHRA PRADESH]

K. RAMGOPAL
PRINCIPAL SECRETARY TO GOVERNMENT (MINES)
To
The Commissioner of Printing, Stationary & Stores Purchase (Ptg. Wing),
Vijayawada. (He is requested to publish the above Notification in the
Extra-ordinary issue of Andhra Pradesh, and arrange to send
1000 copies of the same to Govt. Ind. & Com. (M.II) Department).
The Director of Mines & Geology, Andhra Pradesh, Ibrahimpatnam.
The Chief Executive Officer, SERP, Vijayawada.
All the Joint Director /Deputy Director / Asst. Director of Mines & Geology through the
Director of Mines & Geology, Ibrahimpatnam.
Copy to:
The Secretary to Govt, Ministry of Mines, Govt. of India, Shastry Bhawan, New Delhi.
The Law Department. / The Finance Department.
The P.S to Minister for Mines & Geology. / The PS to Prl. Secretary to Govt., (Mines).
SF/SC (e-file No.INC04-17021(34)/1/2019-PLANNING SEC-DMG, Comp. No.1052464)

Page 7 of 8

You might also like