Calculation Sheet: Checking For Bearing Capacity of Lifting Hooks ACI 318-14 Standard
Calculation Sheet: Checking For Bearing Capacity of Lifting Hooks ACI 318-14 Standard
Calculation Sheet: Checking For Bearing Capacity of Lifting Hooks ACI 318-14 Standard
CALCULATION SHEET
PROJECT : Metro Station PREPARED BY : Ngo Thi Thuy Mai
CONTRACTOR : VNCN E&C CHECKED BY : Ngo Thi Thuy Mai
DATE : 24-Aug-21 APPROVED BY : Ngo Thi Thuy Mai
Checking for Bearing Capacity of Rebar ACI 318-14 Standard
I. REFERENCE DOCUMENT
- ACI 318-14: Building Code Requirements for Structural Concrete
Diameter of Rebar da = 16 mm
AVc
Vcb ed ,V c ,V h ,V Vb 0.25 < Vua = 2.00 Ton Conclusion Fail
AVco
Where in, the strength reduce factor of Rebar in concrete: f = 0.45 (Refer to ACI 318-14 17.3.3)
There in:
- The basic concrete breakout strength of a single anchor in shear in cracked concrete (ACI 318-14 17.5.2.2):
l 0.2
Vb 7 e da a f 'c (c1 )1.5 0.84 Ton
da
- The load-bearing length of the anchor for shear (ACI 318-14 17.5.2.2):
le = hef = 100.0 mm
- The projected concrete failure area of single anchor for calculation of strength in shear (ACI 318-14 17.5.2.1):
AVco = 4.5c2a1 = 45000 mm2
- The projected concrete failure area of lifting hooks for calculation of strength in shear (ACI 318-14 17.5.2.1):
AVc = 1.5c1 (2ca1) = 30000 mm2
- The modification factor for edge effect for a single anchor loaded in shear (ACI 318-14 17.5.2.6)
yed,V = 1
- The modification factor for anchor located in region of a concrete member no cracking (ACI 318-14 17.5.2.7):
yc,V = 1