Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
206 views

Crack Width

This document contains a calculation of crack width for a concrete beam based on ACI 350-01 specifications. It provides the input parameters of the beam, including dimensions, material strengths, reinforcement details, and applied moment. It then shows the calculations to determine the crack width based on the Gergely & Lutz formula. The results determine that the calculated crack width of 0.0121 inches does not satisfy the allowable limit of 0.01 inches.

Uploaded by

Ammar
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
206 views

Crack Width

This document contains a calculation of crack width for a concrete beam based on ACI 350-01 specifications. It provides the input parameters of the beam, including dimensions, material strengths, reinforcement details, and applied moment. It then shows the calculations to determine the crack width based on the Gergely & Lutz formula. The results determine that the calculated crack width of 0.0121 inches does not satisfy the allowable limit of 0.01 inches.

Uploaded by

Ammar
Copyright
© © All Rights Reserved
Available Formats
Download as XLS, PDF, TXT or read online on Scribd
You are on page 1/ 4

Made By S.F.

CRACK WIDTH CALCULATION BASED ON ACI 350-01 Checked By


Project : Job No 1486
Type : Page No 1

INPUT = BLUE CELLS b = 12in


Member = BEAM
f'c = 4 ksi
fy = 60 ksi #5 Bars
h = 20in
b = 12 in
h = 20 in Cc = 2in dc = 2.5in
Cc = 2 in
Bar ɸ = 0.625 in s = 3.5in
d = 17.5 in
dc = 2.5 in
Spacing 's' = 9 in
Mservice = 109.275 k-ft
No of bars 'N' = 3
CALCULATIONS
n = Es/Ec

Es = 29000 ksi

Ec = 57400 √f'c ACI-318-05/8.5.1


= 3630.29 ksi
fc = 2.35 ksi
n = 7.99
x = 6in
As = 2.350 in2 N.A.

fs = Ms d - x = 11.5in
As*(d - x/3)

£M @ N.A. = 0 fs = 36 ksi
b*x2/2 - n*As*(d - x) = 0

x = 6 in

fs = 36.00 ksi A = b*(2*c)/N

c
Z = fs 3√A*c (ACI-350-01 - 10.6.4)
c

Z = 132.625 K/in Not OK s

Fig. R10.6.4 Effective


Allowable Z is tension area of
i) For Severe Environmental Exposure Z = 95 K/in concrete.
ii) For Normal Environmental Exposure Z = 115 K/in

Z = 115 K/in

Crack Width 'W' = 0.076*β*fs 3√A*dc *10-6 Gergely & Lutz Formula For Crack Width
β = 1.2 For Beams
= 0.0121 in β = 1.35 For Slabs
W = 0.0121 > 0.01 Not OK
Made By S.F.
CRACK WIDTH CALCULATION BASED ON ACI 350-01 Checked By
Project : Job No 872
Type : Page No 1

INPUT = BLUE CELLS b = 1000mm


Member = SLAB
f'c = 21 MPa
fy = 410 MPa 12ɸ
h = 300mm
b = 1000 mm
h = 300 mm Cc = 50mm dc = 56mm

Cc = 50 mm
Bar ɸ = 12 mm s = 125mm
d = 244 mm
dc = 56 mm
Spacing 's' = 125 mm
Mservice = 34.2 kN-m
No of bars 'N' = 3
CALCULATIONS
n = Es/Ec

Es = 200 kN/mm2

Ec = 4780 √f'c ACI-318-05/8.5.1


= 21904.7118 N/mm2
fc = 5.45 N/mm2
n = 9.13
x = 55.75mm
As = 904.00 mm2 N.A.

fs = Ms d - x = 188.25mm
As*(d - x/3)

£M @ N.A. = 0 fs = 167.84 N/mm2


b*x /2 - n*As*(d - x) = 0
2

x = 55.75 mm

fs = 167.83 N/mm2 A = 2*c*s

c
Z = fs 3√A*c (ACI-350-01 - 10.6.4)
c

Z = 15.475 kN/mm OK s

Fig. R10.6.4 Effective


Allowable Z is tension area of
i) For Severe Environmental Exposure Z = 17 kN/mm concrete.
ii) For Normal Environmental Exposure Z = 20 kN/mm

Z = 20 kN/mm

Crack Width 'W' = 11.0*β*fs 3√A*dc *10-6 Gergely & Lutz Formula For Crack Width
β = 1.2 For Beams
= 0.2299 mm β = 1.35 For Slabs
W = 0.2299 < 0.266 OK