Urun Katalogu
Urun Katalogu
Urun Katalogu
Index
ECOFRIENDLY
LOCATION
WHY US?
PRODUCTION SITE
QUALITY CERTIFICATIONS
SPECIFICATIONS
MINI-L MODELS
MIDI MODELS
VNTZ MODELS
OTHER DETAILS
WIRING DIAGRAMS
OTHER DETAILS
APPLICATION SPECIFICATIONS - NOTIFICATIONS
HEAVY DUTY CARTON BOX
WOODEN PALLET TYPE
TEST CONDITIONS
Ecofriendly Energy efficient
products,
less electricity
consumption and
lower CO2 footprint
product
Logistic advantage
from Eskişehir to
Lead time 1 week for Turkey and
2 weeks for EU region and North Africa* Eskişehir
Aşağıda ismi ve adresi verilen kuruluş: Arçelik A.Ş. Aşağıda ismi ve adresi verilen kuruluş: Arcelik A.S.
Genel Müdürlük Genel Mudurluk
Sütlüce Karaagaç Caddesi Sutluce Karaagac Caddesi
No:2/6 No:2/6
Beyoğlu/İstanbul Beyoglu/Istanbul
34445 34445
Türkiye Türkiye
Tasarım,Üretim ve Pazarlama Faaliyetlerini Kapsayacak Şekilde Dayanıklı Tüketim Eşyaları Arçelik Bilgi Güvenliği Yönetim Sistemi, ithalat, ihracat, transit, antrepo, gümrükleme, lojistik,
Endüstrisi. depolama, gümrük ve dış ticaret operasyonları ile bu operasyonlara ilişkin Tedarik Zinciri,
Bilişim Teknolojileri, İnsan Kaynakları, Mali İşler, Finansman direktörlüklerinin faaliyetlerini
kapsamaktadır. Bu kapsam 02.07.2015 tarihli BGP-16927 / 2 doküman kodlu uygulanabilirlik
bildirgesi ile uyumludur.
Belgelendirme tarihi: 30/10/2012 Son Belgenin Geçerlilik Tarihi: 23/07/2015 Belgelendirme tarihi: 21/10/2013 Son Belgenin Geçerlilik Tarihi: 12/08/2015
Son basım tarihi: 23/07/2015 Son geçerlilik tarihi: 22/07/2018 Son basım tarihi: 12/08/2015 Son geçerlilik tarihi: 21/10/2016
Sayfa: 1 / 3 Sayfa: 1 / 3
Bu sertifika elektronik olarak yayınlanmıştır, BSI'ya aittir ve sözleşme hükümlerine tabidir. Bu sertifika elektronik olarak yayınlanmıştır, BSI'ya aittir ve sözleşme hükümlerine tabidir.
Elektronik sertifika internet üzerinden tasdik edilebilir. Elektronik sertifika internet üzerinden tasdik edilebilir.
Basılı kopyalar www.bsi-global.com/ClientDirectory adresinden veya +90 216 445 90 38 numaralı telefondan kontrol edilebilir. Basılı kopyalar www.bsi-global.com/ClientDirectory adresinden veya +90 216 445 90 38 numaralı telefondan kontrol edilebilir.
Bilgi ve İletişim: BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes MK5 8PP. Tel: +44 845 080 9000 Bilgi ve İletişim: BSI, Kitemark Court, Davy Avenue, Knowlhill, Milton Keynes MK5 8PP. Tel: +44 845 080 9000
BSI Assurance UK Limited, registered in England under number 7805321 at 389 Chiswick High Road, London W4 4AL, UK. BSI Assurance UK Limited, registered in England under number 7805321 at 389 Chiswick High Road, London W4 4AL, UK.
BSI Grup Şirketleri üyesi. BSI Grup Şirketleri üyesi.
Precise
Production
Measurement
Putting
client into
center;
making
projects
together
WORKING
WITHOUT
INVENTORY
Putting EVERYTHING
clients at JUST IN TIME
the center of
the product
development
process
MINI-L MODELS
DIMENSIONS (mm.)
SERIES BM NO
A B
Oil Charge
Net Wt.
Application
Motor Type
Refrigeran
Ashrae Cecomaf Ashrae
B/M No
Model
-35°C -30°C -25°C -23,3°C -20°C -15°C -10°C -25°C -23,3°C
R600a
LBP
NTZ 145 MT 391-05 9,85 7,5 160 1 1 81 106 137 146 175 224 281 128 1,65
Oil Charge
Net Wt.
Wire
Application
Motor Type
Refrigeran
Ashrae Cecomaf Ashrae
B/M No
Model
-35°C -30°C -25°C -23,3°C -20°C -15°C -10°C -25°C -23,3°C
main/
cc kg cc Kcal/h Kcal/h Kcal/h Kcal/h Kcal/h Kcal/h Kcal/h W W/W
aux
NTU 185 MT 235-05 Al/Al 12,46 8,6 175 1 1 99 132 173 185 226 288 359 161 1,65
Displacement
Oil Charge
Standard Approval
Net Wt.
Control Method
Speed
Application
Motor Type
Refrigeran
B/M No
Model Ashrae Ashrae
45 1,57 1300
76 1,75 2100
VNTZ 105 M 258-05 7,53 6,0 210 2 2
110 1,70 3000
155 1,60 4500
45 1,80 1300
76 1,88 2100
VNTZ 105 M 258-00 7,53 6,0 210 2 2
110 1,80 3000
155 1,66 4500
63 1,71 1300
105 1,75 2100
VNTZ 145 M 255-05 9,85 6,5 210 2 2
147 1,69 3000
Frequency
Drop-In
201 1,58 4500
R600a
VDE*
LBP
63 1,80 1300
105 1,86 2100
VNTZ 145 M 255-00 9,85 6,5 210 2 2
147 1,83 3000
201 1,65 4500
75 1,69 1300
124 1,75 2100
VNTZ 165 M 256-05 11,28 6,5 210 2 2
173 1,71 3000
225 1,58 4500
75 1,79 1300
124 1,87 2100
VNTZ 165 M 256-00 11,28 6,5 210 2 2
173 1,77 3000
225 1,65 4500
* VDE Certificate is ready for VNTZ165 / 256-05 model, for the other models; the certificate will be ready in 4th quarter of 2016
OTHERS DETAILS WIRING DIAGRAMS
Compressor Mounting Shapes
Washer
Compressor Identification
Bolt Clip
Bushing
There must be clearence
between washer and grommet Bushing
There must be clearence
between washer and grommet
1
3
PTCSIR PTCSCR E-PTCSCR
9
2 Lamp Lamp Lamp
Mounting Bracket
Mounting Bracket Door Switch Termostat Door Switch Termostat Door Switch Termostat
4
Overload Protector Overload Protector Overload Protector
Cabinet Base Vibration Grommet Cabinet Base Pin Vibration Grommet
Nut
Dimensions N
L
Fan (*)
C
N
L
Fan (*)
C
N
L
Fan (*)
C
GND S GND S S
GND
8 Start WDG. Start WDG. Start WDG.
PTC PTC PTC ESC
Bracket 10 5 6 7
Compressor Compressor Compressor
Run Capasitor
OTHER DETAILS APPLICATION SPECIFICATIONS - NOTIFICATIONS
Inverter Compressor Identification
Line
1. Do not leave compressors without their plugs more than production date. If longer, vacuum levels of the compressors
10 minutes Compressors with rubber cap removed; must be should be checked before usage.
attached to the system as soon as possible. 10. Use a filter dryer suitable for R600a refrigerant.
2. Don’t incline the compressors more than 5° during storage, 11. Do not operate or supply electrical power unless compressor
transportation or installation and transportation must be made is connected to ground, electric shock may occur.
considering attached drawings. In addition to this avoid compressors 12. The compressor must not be subjected to high voltage tests
from vibration and impact shock during transportation. under vacuum conditions. All TEE compressors have already
3. A dropped or highly impacted compressor must not be used. been submitted to 1.860 V for one second for electrical safety
4. Due to the reason that R600a is higly flammable, all standards.
components; especiallyincluding leakage test equipment must 13. Electrical power must be disconnected when terminal protective
be exclusively designed for R600a and the system must be cover is not in place to avoid electric shock.
1. COMPESSOR MODEL NO VNTU 170 MT
a b c
6. REFRIGERANT R600a welded securely. 14. The TEE Electronic Inverter is made for use only with the
DEFINITION 7. COOLING TYPE 5. Excessive liquid back in refrigeration system must be avoided TEE VNTU Compressors.
a. Compressor Design: VNTU S: Static
to prevent wear on bearings. Furthermore; liquid back can 15. Inverter Compressors should be driven by suitable inverter;
b. Capacity:Compressor cooling capacity O: Oil
(Kcal/hr at 50 Hz) at standart F: Fan
result in cause breakage on the crankshaft, rupture on the otherwise compressor in order to reach best performance.
ASHRAE-T conditions 8. SERIAL NUMBER AND gasket and damage to the suction valve of the compressor. 16. Do not connect the inverter compressors directly to the
c. Refrigerant R600a DATE MANUFACTURE 6. Do not apply direct AC power on terminals of the compressor. AC supply line,otherwise permanent damage may occur.
2. RATED VOLTAGE AND FREQUENCY 9. B/M NUMBER, SERIAL NUMBER, 7. The design of refrigeration system must be suitable to ensure
3. COMPRESSOR B/M (Bill of Material) NO DATE OF MANUFACTURE BARCODE that the oil inside the compressors could flow back to
4. LOCKED ROTOR CURRENT 10. APPROVAL compressor after completing the refrigeration cycle.
5. APPLICATION 8. Compressors should be stored in a dry, non-humid place.
LBP:Low Back Pressure 9. The stocking period must be less than 12 months after the
HEAVY DUTY CARTON BOX WOODEN PALLET TYPE
Strech Film
Polyester Strip
Polyester Strip
Separator Separator
Corrugated Cardboard Wood
Pallet
Pallet
Wood
Wood
TOLERANCES
Efficiency = ±7%