1 DECOMPRESSION BOOTHS

The GGE booths are equipments for decompress CNG


coming from transport units, since a minimum value of 10
bar untill a maximum value of 250 bar, to get a pressure
that allows its use at the reception stations

Generally, the main GGE booths applications are:

■ Industrial uses supplyied by CNG.


■ City gates supplyied by CNG.
■ VNG stations where a booster is not the most convenient
solution.

■ Commercial uses- CNG at low scale.

2 BOOTH COMPONENTS 3 OPERATION MODELS

■ CNG Discharge Manifolds. STANDARD

■ Pressure regulation. (1 or 2 leaps)


■ Metering system
■ Heating system ( gas or electric)
■ Electric panel of control and power

OPTIONALS
■ CNG Discharge Manifolds.
In blue the main components
■ Pressure regulation (1 or 2 leaps). In orange the optional components

4 SERIES
There are two big typologies according to the minumum
The GGE booths are available in various series: pressure at the entry of the compression boxes

■ MODEL @ 10 bar
These are booths that allow to maximize the logistics
and emptying the CNG tanks untill the minimum pressure
SERIE
possible.
600
LOW FLOW

SERIE
■ MODEL @ 20 bar
MEDIUM FLOW 4000 These booths allow emptying the tanks until 20 bar
keeping the flow and under this value the maximum flow
SERIE 8000
is reduced.
HIGH FLOW

The performance of temperature at the gas outlet is a


0 1000 2000 3000 4000 5000 6000 7000 8000 maximum ambient temperatures of 35ºC. For higher
temperatures, the system works but the performance is
lower.

Global Gas Energy S.L. C/ de la Mora 52, 08918 Badalona, Barcelona. Spain T. +34 93 424 53 53 | F. +34 93 325 07 16
CNG PRMS
DECOMPRESSION AND METERING BOOTHS

LOW FLOW SERIE

■ Maximum flow ■ Electric heating MODELS MAXIMUM FLOW


600 m3(s)/h (360 SCFM) 15 WH/m3(s)
CHARACTERISTICS

@ 10 bar LF1 300 m3(s)/h @ 10 bar


■ Operation models
■ Pressure delivered Standard
250 /10 bar LF2 300 m3(s)/h @ 10 bar
■ Layout
■ Outlet pressure 2 CNG Discharge
(fixed) Manifolds + 1 MORE INFORMATION
Adjustable between 2 decompression booth
and 4 bar (200x100xH200 cm) ■ PLC and SCADA system with remote access.
■ Outlet gas ■ Coverage ■ Automatic system and automatic CNG discharge
temperature Steel box manifolds.
Between 10º and 40ºC
■ Adapted solutions for gases coming from pipelines and
wells.

MEDIUM FLOW SERIE

■ Maximum flow ■ Outlet gas


CHARACTERISTICS

REDUNDANCY
600-4.000 m3(s)/h temperature The booths from the serie MF can be completely
(360–2.400 SCFM) @ Entre 10° y 40°C redundants.
10 bar
■ Gas Heating
■ Pressure delivered < 1%
SYSTEMS REDUNDANCY
250 /10 bar
■ Operation DELIVERY FILTERS OPTIONAL
■ Outlet pressure models
(fixed) Standard FIRST LEAP OPTIONAL
Ajustable entre 2 y
7 bar SECOND LEAP OPTIONAL

BOILERS OPTIONAL

PUMPS OPTIONAL

FUEL GAS SYSTEMS OPTIONAL

METERING AND OUTLET PIPE OPTIONAL MANNER A DELIVERE


Flow (m3(s)/h)

In this way, the GGE booths from the MF serie can always
keep the operation requested, even in case of failure of a
basic component during the maintenance. Which means
Pressure delivered
a big reliability, security and efficiency of our clients
businesses.

The graph indicates the relation between the FLOW and


the delivered pressure for the 6 Models of the GGE MF
series. MORE INFORMATIONS
■ “Plug & Play” configuraion
Compact, easy and inexpensive to install and ready for
start up. ■ PLC and SCADA systems with remote access.
■ Automatic System and automatic CNG Discharge
Manifolds.

■ Adapted solutions for pipeline and wells gases.


■ Customized solutions

Global Gas Energy S.L. C/ de la Mora 52, 08918 Badalona, Barcelona. Spain T. +34 93 424 53 53 | F. +34 93 325 07 16
CNG PRMS
DECOMPRESSION AND METERING BOOTHS

HIGH FLOW SERIE

■ Flow range ■ Models


CHARACTERISTICS

From 4000 m3(s)/h to Special customized


8000m3(s)/h; (2400- solutions
4800 SCFM)
■ Gas heating
■ Pressure delivered Consumption <1%
250 /10 bar
■ Operation models
■ Outlet pressure Standard
(fixed)
Adjustable between 2
and 4 bar

5 CNG DISCHARGE MANIFOLDS BACK UP SYSTEM

GGE offers 6 types of CNG DISCHARGE MANIFOLD: BACKUP CNG STORAGE Y PRIORITY PANEL

The selection depends on the required flow for the


instalation, the configuration of the trucks and the The use of a backup storage system with a priority panel can
operation method. improve considerably the logistics of the operations.

There are two Backup CNG Storage basic models:


MANIFOLD TYPE FLOW
HEAVY STORAGE - HS’10
M1 / T1 1.000 m3(s)/h @ 10 bar

M2 / T2 2.000 m3(s)/h @ 10 bar


■ Capacity: 10.260 liters
■ Working pressure: 250 bar
M3 / T3 3.000 m3(s)/h @ 10 bar ■ Gas volume: 3.150 Nm3(*)
HEAVY STORAGE - HS’20

6 OPTIONAL ■ Capacity: 19.380 liters


■ Working pressure: 250 bar
■ Gas volume: 5.950 Nm3(*)
DOM *Depending on the temperature

CNG Discharge can be supplyied with the option of DOM®


(Defueling Operation Manager). 7 GGE’S AFTER SALE: GHS
DOM® is an inteligent tool for the GGE clients and can
provide: The after-sales service of GGE equipments is provided by
GHS ( GAS HELP SERVICES).

■ A database with all the discharge operation information Through the GHS web platform, the GGE clients have
at clients stations. access to:

■ Parameters analysis and automatic report generation. ■ Global Gas Help Services forums
■ Round trip analysis, either for a client or for CNG vehicles. ■ Online shops for spare parts
■ Vehicle identification and automatic discharge parameters ■ Online library
management of the station.
■ Own equipment SCADA system
■ More specialized services.

*If you are interested in obtaining more iformation about DOM check
the FOM/DOM datasheet.

Global Gas Energy S.L. C/ de la Mora 52, 08918 Badalona, Barcelona. Spain T. +34 93 424 53 53 | F. +34 93 325 07 16