This document provides specifications for a rotary gas meter to be supplied to Indraprastha Gas Limited. The key details include:
- The meter is a Raychem RRM G650 DN150-Class150 UNI Basic Index rotary gas meter with a flow range of 6.5-1000 m3/hr and accuracy of ±2% from minimum to 10% of maximum flow and ±1% from 10% to maximum flow.
- It has an IP67 rated meter head with 8-digit display, pulse generator, and meets applicable MID and EN standards.
- Operating parameters include a maximum operating pressure of 6 bar, operating temperature range of -10 to 55°C, and maximum flow
This document provides specifications for a rotary gas meter to be supplied to Indraprastha Gas Limited. The key details include:
- The meter is a Raychem RRM G650 DN150-Class150 UNI Basic Index rotary gas meter with a flow range of 6.5-1000 m3/hr and accuracy of ±2% from minimum to 10% of maximum flow and ±1% from 10% to maximum flow.
- It has an IP67 rated meter head with 8-digit display, pulse generator, and meets applicable MID and EN standards.
- Operating parameters include a maximum operating pressure of 6 bar, operating temperature range of -10 to 55°C, and maximum flow
This document provides specifications for a rotary gas meter to be supplied to Indraprastha Gas Limited. The key details include:
- The meter is a Raychem RRM G650 DN150-Class150 UNI Basic Index rotary gas meter with a flow range of 6.5-1000 m3/hr and accuracy of ±2% from minimum to 10% of maximum flow and ±1% from 10% to maximum flow.
- It has an IP67 rated meter head with 8-digit display, pulse generator, and meets applicable MID and EN standards.
- Operating parameters include a maximum operating pressure of 6 bar, operating temperature range of -10 to 55°C, and maximum flow
This document provides specifications for a rotary gas meter to be supplied to Indraprastha Gas Limited. The key details include:
- The meter is a Raychem RRM G650 DN150-Class150 UNI Basic Index rotary gas meter with a flow range of 6.5-1000 m3/hr and accuracy of ±2% from minimum to 10% of maximum flow and ±1% from 10% to maximum flow.
- It has an IP67 rated meter head with 8-digit display, pulse generator, and meets applicable MID and EN standards.
- Operating parameters include a maximum operating pressure of 6 bar, operating temperature range of -10 to 55°C, and maximum flow
CUSTOMER :- INDRAPRASTHA GAS LIMITED (IGL) CONSULTANT :- VCS QUALITY SERVICES PRIVATE LIMITED PO NUMBER :- IGL/ND/C&P/EP14962 - PO No: 6100004569 Dated 27.12.2018 MANUFACTURER:- RAYCHEM RPG (P) LTD SOR ITEM NO :- Group C - Line Item #5 ISSUE DATE :- 01.02.2019 REVISION No. :- 02 Units :- Gas Flow - Sm3/hr, Pressure - Bar g, Temperature - Deg C, Level / Length - mm 1 MAKE RAYCHEM RPG PVT LTD 2 MODEL RRM G650 DN150-Class150 UNI Basic Index 3 QUANTITY 4 4 F TO F LENGTH 260 MM (Spool is provided to meet 450 MM FtoF distance) 5 G RATING G650 6 FLOW RANGE QMAX- 1000 M3/HR, QMIN-6.5 M3/HR ±2% from Qmin to 0.10max 7 ACCURACY ±1% from 0.1 Qmax to Qmax 8 MAXIMUM INDEX READING 9999999,9 m3 9 REVOLUTION OF LAST COUNTER 0.1 m3 10 METER HEAD IP 67 PROTECTION, 8 DIGIT 11 APPLICABLE STANDARD EN12480 : 2006 / OIML R137 : CH1 12 PULSE GENERATOR 2 LF & 1 AT 13 APPROVAL MID B + D, Weight & Measurement 14 CONNECTION FLANGED END ANSI 150 GENERAL
15 SIZE 6 " -150#
16 REPEATABILITY BETTER THAN ±0.2% 17 CONSTRUCTION STANDARD EN 12480 (LATEST) 18 RANGEABILITY 1 : 100 19 INTRINSIC SAFETY AS PER 2014/34/EU 20 AREA CLASSIFICATION Ex II 2G Ex ia II B T4----T6Gb 21 PRESSURE AND TEMPERATURE TAP ON BODY REQUIRED 22 INSTALLATION OPTION MULTI POSITION Meter Body - Alluminium Impellers - Alluminium Cartridge - Alluminium Shaft/timing gears - Steel SS 23 MATERIAL Timing Gears - Carbon steel Index - Polycarbonate ECI Bearings - Steel SS Body & Cover - Alluminium 24 DESIGN PRESSURE 19 BAR (g) OPERATING CONDITIONS
25 OPERATING PRESSURE 2 BAR (g)
26 MAXIMUM OPERATING PRESSURE 6 BAR (g) 27 OPERATING TEMPERATURE -100 TO 550 C 28 ALLOWABLE PRESSURE DROP < 3 mbar 29 SERVICE FLUID NATURAL GAS 30 MAX FLOW (m3/hr) 2000 SCMH @ 2 BAR (g) PRESSURE 30 LUBRICATION REQUIRED 31 FLOW DIRECTION MARKED ON BODY NON CORROSIVE, FRICTION LESS, ENDRANCE FOR MINIMUM 20 YEARS OF 32 METER INTERNALS LIFE & EXTERNAL TAMPER PROOF. 33 COATING AS PER MIL STANDARD OTHERS
34 VOLUME TOTALIZER MECHANICAL COUNTER
35 SERIAL NO RAY12345678/mmyy 36 LANGUAGE TO BE USED ENGLISH 37 CALIBRATION CERTIFICATE AS PER EN 12480 38 WARRANTY CERTIFICATE REQUIRED 39 QUICK INSTALLATION MANUAL REQUIRED 40 CONICAL FILTER 04 NO'S 41 NRV 04 NO'S 42 RESTRICTING ORIFICE 04 NO's ACCESSORIES
GASKETS(INCLUDING SPARE GASKETS FOR METER &
43 04 NO'S NRV 44 CS COMPANION FLANGE NOT APPLICABLE(Required upto G100 only) 45 FLANGE BOLTS 64 NO'S 46 OIL BOTTLE 500 ml along with 200 ml feeding bottle