06 DM - OC2505 - E01 - 1 OTN ODUK1+1 Protection Configuration 31P

Download as pdf or txt
Download as pdf or txt
You are on page 1of 31

OTN ODUK 1+1 Protection

Configuration
Networking

 A project is a ring network which is composed of three sites of


ZXONE 9700. NEC is OADM site, A and B are OTM sites

Networking Diagram

2
© ZTE Corporation. All rights reserved
Signal Flow

 Configure electrical layer ODUK 1+1 protection between NE A


and NE B

3
© ZTE Corporation. All rights reserved
Configuration Steps
Preparation Create Protection Subnet

Install Boards set Protection


attribute
Wavelength
Tuning
Find Protection
Fiber Relations
Connection

Configure Service Modify


Mapping Protection
Parameters
Configure Cross
Connection

Discover Result
Service Verification

4
© ZTE Corporation. All rights reserved
Install Boards

 To install the needed boards, refer to “Networking Diagram”


and “Signal Flow Diagram”.
 The boards can be discovered automatically in EMS.

5
© ZTE Corporation. All rights reserved
Wavelength Tuning

6
© ZTE Corporation. All rights reserved
Wavelength Tuning

 In the Topology view, right-click NE, select NE Manager, in the


Customized Resource navigation tree, select the service board.

 In the Board Operation navigation tree, select WDM Wavelength


Management > Wavelength Adjustment and Tuning, refresh and
apply.

 Notes: This step is only for line cards that support wavelength
tuning.

7
© ZTE Corporation. All rights reserved
Fiber Connection

 To create fiber connection information, refer to “Networking


Diagram” and “Signal Flow Diagram” .

 The port and the order should be consistent with the equipment.
If the port is wrong, the path cannot be found, and the wrong
connection order will lead to abnormal switching.

8
© ZTE Corporation. All rights reserved
Configure Service Mapping

9
© ZTE Corporation. All rights reserved
Configure Service Mapping

 In Topology View, double-click NE, select the client service


board , right-click NE Manager, in the NE Operation navigation
tree, select WDM Service Configuration ,and set service mapping.

 Notes: Choose the Service Type, Map Mode and ODUk Type.

10
© ZTE Corporation. All rights reserved
Configure Service Mapping

11
© ZTE Corporation. All rights reserved
Configure Service Mapping

 In Topology View, double-click NE, select the line service board ,


right-click NE Manager, in the NE Operation navigation tree,
select WDM Service Configuration, and set the service mapping.

 Notes: Choose the Service Type, Map Mode and ODUk Type.

12
© ZTE Corporation. All rights reserved
Configure FEC Mode

13
© ZTE Corporation. All rights reserved
Configure FEC Mode

 In Topology View, double-click NE, select the line service board ,


right-click NE Manager, in the NE Operation navigation tree,
select WDM Service Configuration, and set FEC Mode.

 Notes: Choose the FEC Mode. For the end to end service signal,
the FEC Mode of both ends must be consistent.

14
© ZTE Corporation. All rights reserved
Configure Cross Connection

15
© ZTE Corporation. All rights reserved
Configure Cross Connection

 In Topology View, right-click NE. Select NE Manager. In the NE


Operation navigation tree, select Common Configuration > Cross
Connection, choose in the Group Selection and Edit, set bidirection, and
1A2Z properties for the cross connection.
 Firstly, click the client board OAC_in port, and connect to the line board
corresponding port in working path, click OK.
 Secondly, click the client board OAC_in port again, and connect to the
line board corresponding port in protection path, click OK and
ApplyPart.
 Then four lines are displayed. Three lines are green, and one line is blue.
Otherwise, check whether previous steps are correct.
 ALL the above configuration should be set on both ends of the service.

16
© ZTE Corporation. All rights reserved
Discover Service

17
© ZTE Corporation. All rights reserved
Discover Service

 In the Service View, select Discover Service Automatically.


 After the auto discovery, select the connection between the NEs.
All the automatic discovery paths are displayed, ensure the OTS,
OMS, OCH paths, and the configured service paths (such as
ODUK path) are there. Otherwise, check whether previous steps
are correct.
 Right-click the path from the service list, select Service Explorer,
check whether the service route information is correct. If not,
check whether previous steps are correct.

18
© ZTE Corporation. All rights reserved
Set ODUK 1+1 Protection Attribute

19
© ZTE Corporation. All rights reserved
Set ODUK 1+1 Protection Attribute

 In Topology View, right-click NE. Select NE Manager. In the NE


Operation navigation tree, select Common Configuration > Cross
Connection, choose in the Group Selection and Edit. In the main
window, four lines are displayed. Click the blue line and click the
Attribute button.
 In the attribute window, set Cross connection label, the WTR times,
Enable, Return mode, Switch type, APS signal tunnel and protect
mode config. Click OK and Applypart.
 Notes: The Cross connection label and protect mode config are
default usually. The APS signal tunnel only need to be set when the
switch type is set as Bidirection.
 ALL the above configuration should be set on both ends of the
service.
20
© ZTE Corporation. All rights reserved
Check SNCP Manager

21
© ZTE Corporation. All rights reserved
Check SNCP Manager

 In Topology View, right-click NE. Select NE Manager. In the NE


Operation navigation tree, select Common Configuration > Cross
Connection. In the main window, click the SNCP manager in the
bottom.
 In the SNCP manager window, some status of ODUK 1+1
protection are displayed.
 Maintenance item shows the external commands of the
Protection Group. If no external command is set, Maintenance
shows clear switch.
 Switch state shows the current actual status of the Protection
Group. In general, the state shows normal or switch. If the EMS
can not get the state, it shows not clear.
22
© ZTE Corporation. All rights reserved
Check SNCP Manager

 Working /Protection channel states show the current state of two


path. The state normally shows OK. If some alarm occur in path,
it shows SF. If signal degradation occur in path, it shows SD.
 Protection effect normally shows Protection effect started. If the
protection is forbidden, it shows Protection effect Paused.
 In the light bottom of the window, the Protection effect item can
enable or disable the Protection by selecting one of the two
options.
 Notes: The protection group should be clicked firstly, or the
Protection effect item can not be handled.

23
© ZTE Corporation. All rights reserved
Check SNCP Manager

 In the bottom right corner of the window, select all means to select all
the Protection groups in the window. Auto refresh means the state of
protection groups will refresh automatically. Clicking refresh item will
refresh the selected Protection groups manually.
 Switch item can give the selected Protection groups different external
commands by different options.
 Treaty Reset item can reset the Protection protocol of the selected
Protection groups when the Protection is forbidden. After the Treaty
Reset is executed, the previous state of Protection and external
commands will be cleared, and the protection will work like a new one.
 No Treaty Switch item can order PSK board directly to switch only one
selected Protection group without the APS when the Protection is
forbidden.

24
© ZTE Corporation. All rights reserved
Configure ODUK 1+1 Protection

25
© ZTE Corporation. All rights reserved
Configure ODUK 1+1 Protection

26
© ZTE Corporation. All rights reserved
Configure ODUK 1+1 Protection

27
© ZTE Corporation. All rights reserved
Configure ODUK 1+1 Protection

28
© ZTE Corporation. All rights reserved
Configure ODUK 1+1 Protection

 Open Protection View, click Search PSN. IN the Search PSN


window, click Search PSN.
 In the Protection Sub-Net, the ODUk 1+1 PSN will be displayed.
Otherwise, check whether previous steps are correct.
 Select the Protection Sub-Net, and click Protection PSN. There
are three items: Attribute, Protect Parameter, Protect Relation.
 In Protect Parameter, some property of the PSN can be modified.
 In Protect Relation, some status of the working/Protecting path
are displayed, including Channel status, Command status, Switch
status and WTR status.

29
© ZTE Corporation. All rights reserved
Result Verification

 1. Verify the protection subnet in Protection View.


 2. Deliver the protection switching command, and check whether
the switching is normal.
 3. Pull the fiber out of the equipment, and check whether the
switching is normal. Check whether the switching event is
correctly reported.

30
© ZTE Corporation. All rights reserved