Pipe Support Fluor PDF Free

Download as pdf or txt
Download as pdf or txt
You are on page 1of 79
At a glance
Powered by AI
The document describes different types of pipe supports including hangers, anchors, guides and extra steel frames. It also provides details on pipe support identification and numbering standards.

The main types of pipe supports described are hangers, anchors, guides and extra steel frames. Directional anchors are indicated with an 'A' symbol and pipe anchors with a 'G' symbol on piping isometrics.

Each pipe support is identified on piping isometrics by one or more frames connecting to a support symbol with a leader line. The top of the frame indicates the support number and the bottom indicates the corresponding support standard number.

MIN.

150
3/4 " DIA. HILTI HIT HY 150 5/8" dia. A325 BOLTS C/W
ADHESIVE ANCHORS (TYP.) NUTS & LOCK WASHERS

SUPPORT COMPONENT SUPPORT COMPONENT SEE NOTE 1


AS SPECIFIED AS SPECIFIED

305

200 50 50

150

150
25mm dia. HOLES 18mm dia. HOLES

20mm THK. PLATE 20mm THK. PLATE

TWO-BOLT CONCRETE HANGER PLATE TWO-BOLT STEEL HANGER PLATE


13.3 kN MAX. LOAD 13.3 kN MAX. LOAD

305

200 50 50
200

200
305

305
25mm dia. HOLES 18mm dia. HOLES

20mm THK. PLATE 20mm THK. PLATE

FOUR-BOLT CONCRETE HANGER PLATE FOUR-BOLT STEEL HANGER PLATE

26.6 kN MAX. LOAD 26.6 kN MAX. LOAD

NOTES

1. WHEN ATTACHED TO UNDERSIDE OF AN EXISTING W SHAPE, SPACING BETWEEN BOLTS


SHOULD MATCH THE USUAL GAUGE OF THE BEAM.

SUPPORT HANGER PLATE /


TAG MATERIAL

758A TWO-BOLT / C.S.

758B FOUR-BOLT / C.S.

758AS TWO-BOLT / 316 S.S.

758BS FOUR-BOLT / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G. ISS’D FOR CONSTRUCTION H.L. CH. Y.T.


EXTRA STEEL- HANGER PLATE
03/28/95

1 T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.


SUP. H.LESKIE
10/22/04 DESIGNATION REVISED

DATE 03/28/95 DS-PS-X758 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX758.DGN
WHERE A PIPE SUPPORT STANDARD INDICATES THAT ELEVATIONS OR DIMENSTONS
ARE TO BE SPECIFIED "ON DWG", THIS INFORMATION SHALL BE GIVEN ON A LINE
ADJACENT TO THE FRAME.

EXAMPLE IDENTIFICATION

PS# WHERE "#" DENOTES THE PIPE SUPPORT


PS#
NUMBER ON THE ISOMETRIC.
eg. PS1, PS2, ETC.

PS-S612 SUPPORT,
PS-S612
DESIGN STANDARD NUMBER
DIM L = 250 DS-PS-S612

L DIMENSION "L" AS SPEC.


ON SUPPORT DETAIL.

3.2 MULTIPLE COMPONENT SUPPORTS

SOME SUPPORT ASSEMBLIES WILL REQUIRE TWO OR MORE FRAMES. EACH FRAME WILL
INDICATE THE DIFFERENT COMPONENT OF THE SUPPORT.

EXAMPLE IDENTIFICATION

PS5 FIFTH PIPE SUPPORT


PS5
ON THE ISOMETRIC.

PS-S608 SUPPORT,
PS-S608
DESIGN STANDARD NUMBER
DS-PS-S608

PS6 SIXTH PIPE SUPPORT


PS6
ON THE ISOMETRIC.

PS-DA251 DIRECTIONAL ANCHOR,


PS-DA251
DESIGN STANDARD NUMBER
DS-PS-DA251

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G. ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT DESIGNATION SHT. 2 OF 4
03/28/95

1 J.H. EXAMPLE 3.2 REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

YY/MM/DD
DATE 03/28/95 DS-PS-101 1
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS101.DGN
3.3 EXTRA SUPPORT STEEL

PIPE SUPPORT ASSEMBLIES INCORPORATING EXTRA STEEL ARRANGEMENTS OF THE


TYPES SHOWN IN THE PIPE SUPPORT STANDARDS SHALL HAVE A SECOND FRAME
INDICATING THE ARRANGEMENT TYPE AND STEEL DESIGNATION CODE.

EXAMPLE IDENTIFICATION

X755 EXTRA STEEL,


PS-X755
DESIGN STANDARD NUMBER
DS-PS-X755
HEIGHT = 1650
DIM L = 1000
DIM A = 350 HEIGHT DIMENSION "H" AS SPEC.
ON SUPPORT DETAIL.

A, L DIMENSION "A" AND "L" AS SPEC.


ON SUPPORT DETAIL.

X702B-9 EXTRA STEEL,


PS-X702B-9
DESIGN STANDARD NUMBER
DS-PS-X702
DIM L = 2000
DIM A = 500
"B" FOR BOLTED CARBON STEEL MEMBER

"9" FOR STEEL CODE NUMBER 9

A, L DIMENSION "A" AND "L" AS SPEC.


ON SUPPORT DETAIL.

3.4 MULTIPLE PIPE SUPPORTS

WHERE SEVERAL PIPES ARE SUPPORTED BY A SINGLE EXTRA STEEL SUPPORT ASSEMBLY,
THE ISOMETRIC OF ONE PIPE WILL INCLUDE A FRAME TO CALL OUT THE EXTRA STEEL.
THE ISOMETRICS OF ALL OTHER PIPES SUPPORTED BY THIS EXTRA STEEL WILL SHOW
A FRAME DENOTING THE EXTRA STEEL AS "REF".

EXAMPLE

SUPPORT:
DS-PS-S603 PIPE 1 2 3 EXTRA STEEL:
(TYP. 3X) DS-PS-X703

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G. ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT DESIGNATION SHT. 3 OF 4
03/28/95

1 J.H. EXAMPLE 3.5 REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

DATE 03/28/95 DS-PS-102 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS102.DGN
3.4 ISOMETRIC FOR PIPE #1:

EXAMPLE IDENTIFICATION

PS-S603 SUPPORT,
PS-S603
DESIGN STANDARD NUMBER
DS-PS-S603

PS-X703 EXTRA STEEL,


PS-X703
DESIGN STANDARD NUMBER
DS-PS-X703

ISOMETRIC FOR ALL OTHER PIPES:

EXAMPLE IDENTIFICATION

PS-S603 SUPPORT,
PS-S603
DESIGN STANDARD NUMBER
DS-PS-S603

PS-X703 (REF) REFERENCE TO


PS-X703 (REF)
EXISTING EXTRA STEEL

3.5 SPECIAL SUPPORT DETAILS

SPECIAL PIPE SUPPORTS THAT DO NOT CONSIST OF ELEMENTS CONTAINED IN THE


SUPPORT STANDARDS SHALL BE DETAILED ON A SEPARATE SUPPORT DRAWING.
AN UNIQUE ITEM CODE WILL BE ASSIGNED TO EACH SPECIAL SUPPORT DETAIL.
IN THESE CASES, THE FRAME ON THE ISOMETRIC SHALL REFERENCE THE ITEM CODE.

EXAMPLE IDENTIFICATION

SD-100 UNIQUE ITEM


SD-100
CODE ASSIGNED
TO SPECIAL SUPPORT DETAIL.

SUPPORTS CONSISTING OF COMBINATIONS OF STANDARD TYPES AND SPECIAL DETAILS


SHALL BE SHOWN COMPLETE IN THE DETAILS RATHER THAN USING FRAMES WHICH
ATTEMPT TO DENOTE THE MIXED TYPES.

AN EXCEPTION TO THE ABOVE IS MULTIPLE PIPE SUPPORT CASES SIMILAR TO 3.3


WHERE IT IS PERMISSIBLE TO HAVE A SPECIAL DETAIL OF THE SUPPORT STEEL
AND USE STANDARD FRAMES FOR THE INDIVIDUAL PIPE SUPPORTS.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G. ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT DESIGNATION SHT. 4 OF 4
03/28/95

1 J.H. EXAMPLE 3.5 REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

2 D.K.
11/18/05
EXAMPLE 3.5 REVISED B.C. DATE 03/28/95 DS-PS-103 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS103.DGN
ENGINEERING DATA
LOAD CARRYING CAPACITIES OF THREADED ASTM A 36 CARBON STEEL ROD

MAXIMUM SAFE LOADS, (kN)


NOM. ROD TEMPERATURE OF 340^C
ROD
DIA. FIELD SHOP
THREADED THREADED

3/8" 2.7

1/2" 5

5/8" 8
SEE NOTE 3

3/4" 12

7/8" 16.7

1" 22

1 1/4" 35.5

1 1/2" 51.7

1 3/4" 69.8

2" 92

2 1/4" 121
SEE
NOTE 2 149
2 1/2"

2 3/4" 185

3" 225

NOTES

1. HANGER ROD DIAMETER, IF NOT SPECIFIED WITH PIPE SUPPORT SELECTION, SHALL
BE IN ACCORDANCE WITH THE TABLE ABOVE.

2. HANGER RODS 1 3/4" dia. AND LARGER SHALL BE SHOP THREADED.

3. IN NO CASE SHALL HANGER RODS LESS THAN 3/8" dia. BE USED FOR SUPPORT OF PIPE
2" dia. AND SMALLER, OR LESS THAN 1/2" dia. ROD FOR SUPPORTING PIPE 2 1/2" dia. AND
LARGER.

4. TEMPERATURE OF HANGER ROD SHALL BE BASED ON A TEMPERATURE GRADIENT OF


37^C PER 25mm DISTANCE FROM THE OUTSIDE SURFACE OF THE PIPE.

5. WHEN SELECTING HANGER RODS FOR DOUBLE RISER LUGS & DOUBLE TRUNNIONS
ON RISERS USED FOR RIGID HANGERS, THE SIZE OF A SINGLE ROD SHALL
BE BASED ON THE TOTAL RISER LOAD AS ONLY ONE OF THE TWO RODS MAY
CARRY THE TOTAL LOAD.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. HANGER DATA
1 T.G. NOTES 1 & 5 REVISED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
03/19/96

DATE 03/28/95 DS-PS-113 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS113.DGN
PIPE CLAMPS

THE FOLLOWING SHEETS CONTAIN VARIOUS CLAMP DIAGRAMS WITH SPECIFIC APPLICATIONS.

THEY ARE NOTED BY A FIGURE NUMBER. SOME ARE RELATED TO OTHER SUPPORT ITEMS

WHICH ARE TO BE FOUND IN THEIR PERTINENT DESIGN STANDARDS.

NOTES FOR THE PIPE CLAMP FIGURES IN THIS STANDARD ARE FOUND BELOW.

NOTES

1. CLAMP SHALL MATCH THE OUTSIDE DIAMETER OF PIPE AS SPECIFIED IN PIPING


CLASSIFICATION STANDARDS. FOR S.S. PIPING, A WOVEN HEAT-RESISTANT FABRIC
SUCH AS 1/16" THK "THERMOFAB" CLOTH TAPE MANUFACTURED BY ALBION
INDUSTRIAL PRODUCTS OR APPROVED EQUAL MUST BE BONDED TO INSIDE OF
CLAMP. THE WIDTH SHALL BE EQUAL TO THE CLAMP WIDTH.

2. DIMENSIONS "C" AND "D" ARE RECOMMENDED ONLY AND MAY BE MODIFIED
PROVIDING LOAD CARRYING CAPACITIES ARE MAINTAINED WITH A MINIMUM
SAFETY FACTOR OF 5.

3. HANGER ROD DIAMETER IF NOT SPECIFIED WITH PIPE SUPPORT SELECTION


SHALL BE IN ACCORDANCE WITH PIPE CLAMP SELECTION TABLES ON
DS-PS-121, DS-PS-122 & DS-PS-125.

4. HANGER RODS 1 3/4" DIA. AND LARGER SHALL BE SHOP THREADED.

5. IN NO CASE SHALL HANGER RODS LESS THAN 3/8" DIA. BE USED FOR
FOR SUPPORT OF PIPE.

6. TEMPERATURE OF HANGER ROD SHALL BE BASED ON A TEMPERATURE GRADIENT


37^C PER 25mm DISTANCE FROM THE OUTSIDE SURFACE OF THE PIPE.

7. CARBON STEEL PIPE CLAMPS MAX. LOAD RANGE GIVEN FOR 340^C. FOR HIGHER
TEMPERATURES UP TO 400^C, USE 87% OF LOAD SHOWN.

8. RISER CLAMPS PER DS-PS-123 AND 124 SHALL BE USED AS FOLLOWS:


- TO SUPPORT PIPE LINES 6" DIA. AND LARGER.
- TO SUPPORT LOADS THAT REQUIRE A ROD 3/4" AND LARGER.

9. VERTICAL STAINLESS STEEL PIPE LINES REQUIRING RISER CLAMP SUPPORTS


SHALL BE REINFORCED AS SPECIFIED OR WITH STAINLESS STEEL HALF-PIPE
SEGMENTS MADE FROM PIPE OF EQUAL DIAMETER, THICKNESS AND MATERIAL AS
THE PIPELINE ITSELF.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-121, DS-PS-122, DS-PS-123, DS-PS-124, DS-PS-125
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. HANGER DATA
1 T.G. NOTES 3 REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
03/19/96

2 T.G.
10/22/04
REF. STANDARDS ADDED DATE 03/28/95 DS-PS-120 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS120.DGN
"R"

"D"
"C" STOCK SIZE

PI
PE
O.
D.

"D"
SPACER FOR
FIG. 216 ONLY

ANVIL INTL. FIG. 212, FIG. 216 & FIG. HS-42SD.


TW0 BOLT PIPE CLAMP
CARBON STEEL ASTM A36 OR EQUAL

MODERATE LOADS HEAVY LOADS


ANVIL INTL. FIG. 212 OR EQUAL ANVIL INTL. FIG. 216, FIG. HS-42SD OR EQUAL

NOM STOCK CAPACITY RECOM. STOCK CAPACITY RECOM.


PIPE "D" SIZE IN (kN) ROD SIZE "D" SIZE IN (kN) ROD SIZE
DIA. "C" TO 340^C "R" "C" TO 340^C "R"
Note 1 Note 2 Note 2 Note 7 Note 3 Note 2 Note 2 Note 7 Note 3

1/2" 3/8" 1/8" x 1" 2.2 3/8"


3/4" 3/8" 1/8" x 1" 2.2 3/8"
1" 3/8" 1/8" x 1" 2.2 3/8"

1 1/4" 3/8" 1/8" x 1" 2.2 3/8"


1 1/2" 3/8" 1/8" x 1" 3.5 1/2"
2 3/8" 1/4" x 1" 4.6 1/2"

2 1/2" 1/2" 1/4" x 1" 4.6 1/2"


3" 1/2" 1/4" x 1" 4.6 1/2" 3/4" 3/8" x 2" 15 7/8"

4" 5/8" 1/4" x 1 1/4" 4.6 5/8" 7/8" 3/8" x 2" 15.6 7/8"
5" 5/8" 1/4" x 1 1/4" 4.6 5/8" 7/8" 3/8" x 2" 15.6 7/8"
6" 3/4" 3/8" x 1 1/2" 7.2 3/4" 1" 1/2" x 2 1/2" 21.6 1"

8" 3/4" 3/8" x 1 1/2" 7.2 3/4" 1" 1/2" x 2 1/2" 21.6 1"

10" 7/8" 1/2" x 2" 11 7/8" 1 1/4" 5/8" x 2 1/2" 26.6 1 1/8"
12" 7/8" 1/2" x 2" 11 7/8" 1 1/2" 3/4" x 3" 38.5 1 1/2"

14" 7/8" 1/2" x 2 1/2" 11 1" 1 1/2" 3/4" x 3 1/2" 40.5 1 1/2"
16" 7/8" 7/8" 11 1" 1 1/2" 3/4" x 3 1/2" 40.5 1 1/2"
18" 1" 5/8" x 2 1/2" 13.6 1" 1 1/2" 3/4" x 3 1/2" 61.3 1 3/4"

20" 1 1/8" 5/8" x 2 1/2" 13.6 1 1/4" 1 1/2" 3/4" x 3 1/2" 68 2"
24" 1 1/4" 5/8" x 3" 13.6 1 1/4" 2 1/4" 1" x 6" 72.5 2"
28" 2 1/4" 1" x 8" 80 2"
30" 1 1/2" 3/4" x 4" 15.5 1 1/2" 2 1/2" 1 1/4" x 7" 91.1 2"
32" 2 1/2" 1 1/4" x 8" 105.6 2 1/4"
34" 2 1/2" 1 1/4" x 8" 111 2 1/4"
36" 2 3/4" 1 1/2" x 8" 124.5 2 1/2"
40" 3" WIDTH= 10" 155 2 3/4"
42" 2 3/4" 1 3/4" x 10" 155 2 3/4"
48" 3" WIDTH= 10" 155 2 3/4"

FOR REFERENCE NOTES, SEE DESIGN STANDARD DS-PS-120.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-120
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. PIPE CLAMP DATA
T.G. "GRINNELL" CHG’D TO "ANVIL INTL." DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 REF. STANDARDS ADDED

DATE 03/28/95 DS-PS-121 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS121.DGN
"R"

"D"
SPACER

INSULATION

PE
PI
D.
O.
"C" STOCK SIZE

"D"
ANVIL INTL. FIG. 295, FIG. 295H & FIG. HS-41SD
THREE BOLT PIPE CLAMP
CARBON STEEL ASTM A36 OR EQUAL

MODERATE LOADS HEAVY LOADS


ANVIL INTL. FIG. 295 OR EQUAL ANVIL INTL. FIG. 295H, FIG. HS-41SD OR EQUAL

RECOM. RECOM.
STOCK CAPACITY STOCK CAPACITY
NOM ROD ROD
"D" SIZE IN (kN) "D" SIZE IN (kN)
PIPE SIZE SIZE
"C" TO 340^C "C" TO 340^C
DIA. "R" "R"
Note 1 Note 2 Note 2 Note 7 Note 3 Note 2 Note 2 Note 7 Note 3

3/4" 3/8" 3/16" x 1" 4.2 1/2"


1" 3/8" 3/16" x 1" 4.2 1/2"

1 1/4" 3/8" 3/16" x 1" 4.2 1/2"

1 1/2" 5/8" 1/4" x 1 1/4" 6.8 5/8"


2" 5/8" 1/4" X 1 1/4" 6.8 5/8"
2 1/2" 5/8" 1/4" X 1 1/4" 6.8 5/8"

3" 5/8" 1/4" X 1 1/4" 6.8 5/8"


4" 3/4" 5/16" x 2" 11.1 3/4"

5" 3/4" 5/16" x 2" 11.1 3/4"


6" 7/8" 3/8" x 2 1/2" 12.7 7/8" 1" 3/8" x 2 1/2" 15.3 1"
8" 7/8" 3/8" x 2 1/2" 12.7 7/8" 1 1/8" 1/2" x 2 1/2" 21.3 1 1/4"

10" 1" 1/2" x 2 1/2" 14.2 1" 1 1/4" 1/2" x 3 1/2" 24.4 1 1/4"
12" 1" 1/2" x 2 1/2" 14.2 1" 1 3/8" 5/8" x 3 1/2" 31.1 1 1/2"
14" 1 1/4" 5/8" x 3" 19.1 1" 1 1/2" 3/4" x 4" 42.2 1 3/4"

16" 1 1/4" 5/8" x 3" 19.1 1" 1 3/4" 3/4" x 4 1/2" 44.4 1 3/4"
18" 1 1/4" 5/8" x 3" 19.1 1" 2" 1" x 4" 61.3 1 3/4"
20" 1 3/8" 3/4" x 3" 24.4 1 1/4" 2" 1" x 5" 68.0 1 3/4"

24" 1 3/8" 3/4" x 3" 20 1 1/4" 2" 1" x 6" 72.5 2"
28" 1 1/4" 3/4" x 4" 26.6 1 1/4" 2 1/4" 1" x 7" 80 2"
30" 1 3/8" 3/4" x 5" 33.3 1 1/2" 2 1/4" 1" x 8" 91.1 2 1/4"
32" 1 1/2" 3/4" x 6" 36.7 1 1/2" 2 1/2" 1 1/4" x 8" 105.6 2 1/4"
34" 1 3/4" 1" x 5" 43.6 1 1/2" 2 1/2" 1 1/2" x 7" 111.2 2 1/4"
36" 1 3/4" 1" x 5" 46.7 1 1/2" 2 3/4" 1 1/2" x 8" 124.5 2 1/2"
40" 3" WIDTH= 10" 155 2 3/4"
42" 3" WIDTH= 10" 155 2 3/4"
48" 3 1/4" WIDTH= 12" 175 3"

FOR REFERENCE NOTES, SEE DESIGN STANDARD DS-PS-120.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-120
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. PIPE CLAMP DATA
T.G. "GRINNELL" CHG’D TO "ANVIL INTL." DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 REF. STANDARDS ADDED

DATE 03/28/95 DS-PS-122 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS122.DGN
TACK WELD ONE
SIDE (TYP.)

ON STOCK 8" AND WIDER, USE


"T" 2 BOLTS "E" WITH PIPE SPACERS

"W"
LOAD BOLT "D" DIA

BAR SPACER (TYP.2)


"F" WIDE x 1/2" THK
D.
O.

PIPE SPACER (TYP)

45^
TYP. "C" STOCK SIZE

(4) TOP SHEAR LUGS "G" TO


BE SUPPLIED BY SHOP OR
FIELD FABRICATOR.
(MATERIAL SAME AS PIPE)

SEE NOTE 1
TYP. 3 SIDES
10

"A" "B" "B" "A"

DOUBLE RISER PIPE CLAMP


FIG. 414A (BASED ON ANVIL INTL. FIG. 40)
FIG. 414B, 414C, 414D (BASED ON ANVIL INTL. FIG 40SD)

FOR REFERENCE DIMENSIONS & NOTES, SEE DESIGN STANDARD DS-PS-125.

NOTES:

1. FOR RUBBER LINED OR INTERNALLY COATED PIPE, LUGS TO BE SHOP WELDED PRIOR TO
RUBBER LINING OR INTERNAL COATING. ALL OTHER PIPE SHALL HAVE LUGS WELDED
AFTER PIPE INSTALLATION.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-125
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. RISER CLAMP DATA
1 T.G. CLAMP FIG. No.s REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

2 T.G.
10/22/04
"GRINNELL" CHG’D TO "ANVIL INTL."
REF. STANDARDS ADDED
DATE 03/28/95 DS-PS-123 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS123.DGN
TACK WELD ONE
SIDE (TYP.)

ON STOCK 8" AND WIDER, USE


"T" 2 BOLTS "E" WITH PIPE SPACERS

"W"
LOAD BOLT "D" DIA

BAR SPACER (TYP.2)


"F" WIDE x 1/2" THK
D.
O.

PIPE SPACER (TYP)

45^
TYP. "C" STOCK SIZE

(4) TOP SHEAR LUGS "G" TO


BE SUPPLIED BY SHOP OR
FIELD FABRICATOR
(MATERIAL SAME AS PIPE)

SEE NOTE 2
TYP. 3 SIDES
10

"B" "A"

FIG. 415A & 415B


SINGLE RISER PIPE CLAMP
(BASED ON ANVIL INTL. FIG. 41SD OR EQUAL)
FOR REFERENCE DIMENSIONS & NOTES, SEE DESIGN STANDARD DS-PS-125.

NOTES:

1. SINGLE RISER TO BE USED ONLY WHEN DOUBLE RISER CLAMP AS PER DS-PS-123
CANNOT BE USED.

2. FOR RUBBER LINED OR INTERNALLY COATED PIPE, LUGS TO BE SHOP WELDED PRIOR TO
RUBBER LINING OR INTERNAL COATING. ALL OTHER PIPE SHALL HAVE LUGS WELDED
AFTER CLAMP INSTALLATION.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-123, DS-PS-125
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. RISER CLAMP DATA
1 T.G. CLAMP FIG. No.s REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

2 T.G.
10/22/04
"GRINNELL" CHG’D TO "ANVIL INTL."
REF. STANDARDS ADDED
DATE 03/28/95 DS-PS-124 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS124.DGN
ENGINEERING DATA FOR RISER CLAMPS

LOAD CARRYING CAPACITY IN kN. FOR RIGID HANGER RISER CLAMP APPLICATION
AT TEMPERATURE OF PIPELINE UP TO 400^C (SEE NOTE 5 BELOW)

NOM "C" "D" "E" "F" "G"


PIPE CLAMP STOCK BOLTS BOLTS SPACER SHEAR LUG SIZE ROD
DIA. FIG. No. "A" "B" SIZE (No) DIA x LGTH (No) DIA x LGTH SIZE "W" x "T" x LGTH SIZE

6 414A, 415A 13.3 2 12" 3/4 x 4 (2) 5/8 x 4 3/4 (2) 5/8 x 4 3/4 1 1 x 3/4 x 3 7/8

8 414A, 415A 13.3 2 13 1/2 3/4 x 5 (2) 5/8 x 4 3/4 (2) 5/8 x 4 3/4 1 1 1/4 x 3/4 x 3 7/8

10 414A, 415A 24.4 2 15 1x6 (2) 7/8 x 4 (2) 7/8 x 5 1 1/2 1 1/2 x 3/4 x 4 1 1/4

12 414A, 415A 34.6 2 1/2 16 1x7 (2) 1 x 5 1/2 (2) 1 x 5 1/2 1 3/4 1 1/2 x 1 1/4 x 4 1 1/2

14 414A, 415A 34.6 2 1/2 17 1x7 (2) 1 x 5 1/2 (2) 1 x 5 1/2 1 3/4 1 3/4 x 1 1/4 x 4 1 1/2

16 414A 40.0 2 1/2 18 1 1/4 x 6 (2) 1 1/8 x 6 (2) 1 1/8 x 6 2 2 x 1 1/4 x 4 1 1/2

18 414A 40.0 2 1/2 19 1/2 1 1/4 x 7 (2) 1 1/8 x 6 1/2 (2) 1 1/8 x 6 1/2 2 2 x 1 1/2 x 5 1 1/2

20 414A 60.0 3 21 1 1/2 x 8 (2) 1 3/8 x 8 (4) 1 3/8 x 8 2 1/2 2 x 1 1/4 x 6 1 3/4

24 414A 60.0 3 22 1/2 1 1/2 x 8 (2) 1 3/8 x 9 (4) 1 3/8 x 9 2 1/2 2 1/2 x 1 1/4 x 6 1 3/4

414B 49.4 2 1/2 1 1/2 x 10 (2) 1 1/4 x 8 1/4 (4) 1 x 7 3/4 2 1/4 2 1/2 x 1 3/4 x 5 1 3/4
28
30 414C 83.8 3 1/2 2 x 12 (2) 1 3/4 x 11 (4) 1 3/8 x 10 1/4 3 2 1/2 x 1 3/4 x 6 2
414D 141.6 4 1/2 2 x 16 (2) 2 1/4 x 13 (4) 1 3/4 x 12 4 2 1/2 x 2 x 9 2 1/2

414B 40.0 2 1/4 1 1/2 x 10 (2) 1 1/8 x 7 3/4 (4) 7/8 x 7 1/4 2 2 1/2 x 1 3/4 x 4 1 1/2
31
36 414C 72.2 3 2 x 12 (2) 1 1/2 x 10 (4) 1 1/8 x 9 1/4 2 1/2 2 1/2 x 1 3/4 x 6 2
414D 158.3 4 1/2 2 x 20 (2) 2 1/4 x 13 (4) 1 3/4 x 12 4 2 1/2 x 2 x 10 2 3/4

** ALL DIMENSIONS (in)

NOTES

1. LOADS ARE BASED ON USING ASTM A36 STEEL UP TO 400^C AND A387 GR. D BEYOND.
STUDS AND NUTS ARE TO ASTM A193 B7 AND A194.

2. WHEN SELECTING HANGER RODS FOR DOUBLE RISER CLAMPS & DOUBLE RISER LUGS,
USED WITH RIGID HANGERS, THE SIZE FOR A SINGLE ROD SHALL BE BASED ON THE TOTAL
LOAD AS ONLY ONE OF THE TWO RODS MAY CARRY THE TOTAL LOAD.

3. A STRICT CONTACT TOLERANCE MUST BE GUARANTEED BETWEEN SHEAR LUGS AND RISER
CLAMP SO THAT THE RISER CLAMP HAS COMPLETE CONTACT ON ALL SHEAR LUGS
SIMULTANEOUSLY UNDER ALL LOADING CONDITIONS.

4. THREADED CONNECTIONS SHALL HAVE EITHER LOCK NUTS, DOUBLE NUTS OR COTTER PINS
TO PREVENT THEM FROM VIBRATING LOOSE.

5. THE TABLE ABOVE REFLECTS THE ANVIL INTL. HANGER STD. 40 RISER CLAMP PROGRAM.

6. VERTICAL S.S. PIPE REQUIRING RISER CLAMP SUPPORTS SHALL BE REINFORCED PER DESIGN
STANDARD DS-PS-S600 UNLESS OTHERWISE SPECIFIED ON DWG.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. RISER CLAMP DATA
1 T.G. CLAMP DATA REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

2 T.G.
10/22/04
"GRINNELL" CHG’D TO "ANVIL INTL."
REF. STANDARDS ADDED
DATE 03/28/95 DS-PS-125 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS125.DGN
"N" "Q"

STOCK THICKNESS "C"

"P"
"D"

"M" "L"

ANVIL INTL. FIG. 432


SPECIAL PIPE CLAMP
CARBON STEEL ASTM A36 OR EQUAL

NOM STOCK APPROX.


PIPE "D" THICKNESS WEIGHT
DIA. "C" "L" "M" "N" "P" "Q" IN LBS.
Note 1 Note 2 Note 2

2 1/2" 5/16" 1/8" 6" 5 1/4" 4 1/4" 1/4" 4 1/2" 3


3" 5/16" 1/8" 6" 5 7/8" 5" 1/4" 4 1/2" 3
3 1/2" 5/16" 1/8" 6" 6 3/8" 5 1/2" 1/4" 4 1/2" 4

4" 5/16" 1/8" 6" 6 15/16" 6 1/16" 1/4" 4 1/2" 4

5" 5/16" 1/8" 6" 8" 7" 1/4" 4 1/2" 5

6" 3/8" 3/16" 9" 9 1/2" 8 3/8" 3/8" 6" 12

8" 3/8" 3/16" 9" 11 1/2" 10 3/8" 3/8" 6" 15


10" 3/8" 3/16" 9" 13 5/8" 12 1/2" 1/2" 6" 18
12" 3/8" 3/16" 9" 15 11/16" 14 9/16" 1/2" 6" 21

14" 1/2" 1/4" 12" 17 7/16" 16 1/16" 1/2" 8" 41


16" 1/2" 1/4" 12" 19 7/16" 18 1/16" 1/2" 8" 46
18" 1/2" 1/4" 12" 21 7/16" 20 1/16" 1/2" 8" 52

20" 1/2" 1/4" 12" 23 7/16" 22 1/16" 5/8" 8" 57

24" 1/2" 1/4" 12" 27 1/2" 26 1/4" 5/8" 8" 67

FOR REFERENCED NOTES SEE DESIGN STANDARD DS-PS-120.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-120
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. PIPE CLAMP DATA
T.G. "GRINNELL" CHG’D TO "ANVIL INTL." DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 REF. STANDARDS ADDED

DATE 03/28/95 DS-PS-126 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS126.DGN
REINFORCING PAD PER

OR "H" AS SPEC.
DESIGN STANDARD
DS-PS-S600 FOR

ON DRAWING
THIN WALL ONLY
IF SPECIFIED ON DRAWING.
CARBON STEEL
OR THIN WALL
PIPE

100 WITH

12
5 REPAD

TYP
38x25
WITHOUT
5 INSULATION
REPAD
13 BAND SLOT
TYP.

TYP
6 50mm FOR ANCHORING TO
SEE NOTES
CONCRETE, OR BOLT GAUGE
4 AND 7 455 TO SUIT SUPPORT STEEL

FOR BOLTED ATTACHMENT,


12
USE (4) 5/8 " DIA. A325 BOLTS
5 C/W NUTS & LOCK WASHERS
IF ANCHORED TO STEEL OR
(4) 5/8 " DIA. x 5" LONG HILTI
HIT HY 150 ADHESIVE ANCHORS
IF ANCHORED TO CONCRETE
25 25
SEE NOTE 5.

150

NOTES:
1. THIS ANCHOR IS APPLICABLE TO LINES 3" TO 10" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. SIZE BOLT HOLES IN BASE PLATE TO SUIT CONNECTION BOLT OR ANCHORS.

4. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.


5. FOR BOLTED ATTACHMENT MAXIMUM AXIAL LOAD 11.1 kN, MAXIMUM LATERAL LOAD 3.1 kN.
6. THIS ANCHOR IS NOT SUITABLE FOR RUBBER LINED OR INTERNALLY COATED PIPE.
USE DESIGN STANDARD DS-PS-A203 INSTEAD.
7. WELD TO STEEL MEMBERS OR FIELD DRILL BASEPLATE TO SUIT CONCRETE
ANCHOR DETAIL.

SUPPORT SUPPORT
TAG MATERIAL

200B BOLTED/C.S.

200W WELDED/C.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G. ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR


03/28/95

1 T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.


SUP. H.LESKIE
10/22/04 KWIK-BOLTS CHANGED TO HILTI HIT

2 D.K.
11/18/05
ADDED WELDED OPTION B.C. DATE 03/28/95 DS-PS-A200 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA200.DGN
REINFORCING PAD PER
DESIGN STANDARD

OR "H" AS SPEC.
DS-PS-S600 FOR
THIN WALL ONLY

ON DRAWING
CARBON STEEL IF SPECIFIED ON DRAWING.

OR THIN WALL

PIPE

100

WITH
12

6 REPAD

TYP
38x25
WITHOUT 6
INSULATION
REPAD
13 BAND SLOT
TYP.

TYP
125mm FOR ANCHORING TO
6 455
SEE NOTES
CONCRETE, OR BOLT GAUGE
4 AND 7
TO SUIT SUPPORT STEEL

12

TYP TYP FOR BOLTED CONNECTION,


6 USE (4) 5/8 " DIA. A325
BOLTS C/W NUTS & LOCK WASHERS
IF ANCHORED TO STEEL OR
(4) 3/4 " DIA. x 9" LONG HILTI
165 HIT HY 150 ADHESIVE ANCHORS
IF ANCHORED TO CONCRETE
( SEE NOTE 5 )

25 25

305

NOTES:
1. THIS ANCHOR IS APPLICABLE TO LINES 12" TO 18" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. SIZE BOLT HOLES IN BASE PLATE TO SUIT CONNECTION BOLTS OR ANCHORS.
4. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.
5. FOR BOLTED CONNECTION MAXIMUM AXIAL LOAD 22.2 kN, MAXIMUM LATERAL LOAD 11.1 kN.
6. THIS ANCHOR IS NOT SUITABLE FOR RUBBER LINED OR INTERNALLY COATED PIPE.
USE DESIGN STANDARD DS-PS-A204.
7. WELD TO STEEL MEMBER OR FIELD DRILL BASEPLATE TO SUIT CONCRETE ANCHOR DETAIL.

SUPPORT SUPPORT
TAG MATERIAL

201B BOLTED/C.S.

201W WELDED/C.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G. ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR


03/28/95

1 T.G. REF. STANDARDS ADDED Y.T. DESIGN STANDARD NO. REV.


SUP. H.LESKIE
20/10/04 HILTI ANCHOR TYPE CHG’D

2 D.K.
11/18/05
ADDED WELDED OPTION B.C. DATE 03/28/95 DS-PS-A201 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA201.DGN
OR "H" AS SPEC.

ON DRAWING
CARBON STEEL
OR THIN WALL

PIPE
38x25 INSULATION
BAND SLOT

B.O.P.

100
TYP
7 150

12
150 150

455
TYP
7 150

REINFORCING PAD PER FOR CONNECTION INFO


DESIGN STANDARD SEE NOTES 3 & 4.
DS-PS-S600

TYP
5 100-165
90

PIPE
"A"
DIA.

20" 305

TYP 24" 380


5
28" 455
"A"
TYP.
12

30" 510

32" 560

36" 610
90

13
TYP.

NOTES:
1. THIS ANCHOR IS APPLICABLE TO LINES 20" TO 36" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY THE STRUCTURAL ENGINEER
4. WELD TO STEEL MEMBERS OR FIELD DRILL BASEPLATE TO SUIT CONCRETE ANCHOR DETAIL.

5. THIS ANCHOR IS NOT SUITABLE FOR RUBBER LINED OR INTERNALLY COATED PIPE.
USE DESIGN STANDARD DS-PS-A205 INSTEAD.

SUPPORT SUPPORT
TAG MATERIAL

202 C.S.

202S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

2 D.K.
11/23/05
MODIFIED REPAD DETAIL B.C. DATE 03/28/95 DS-PS-A202 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA202.DGN
OR "H" AS SPEC.
PIPE
"W" "T" "W"
DIA.

ON DRAWING
3"-4" 10 50

"T"
NON-THIN WALL
S.S, ALLOY OR 6"-10" 12 75
RUBBER LINED C.S. PIPE

B.O.P. SEE
NOTE 8

100
5

TYP.
12 5

38x25
INSULATION
BAND SLOT
TYP. 13
6
SEE NOTES TYP.
5 AND 9
50mm FOR ANCHORING TO
MIN. 455 CONCRETE, OR BOLT GAUGE
OR "L" AS SPEC. ON DRAWING TO SUIT SUPPORT STEEL
(SEE NOTE 7)
25 TYP.

(4) SHEAR LUGS PIPE CLAMP


MATERIAL SAME AS PIPE ANVIL INTL. FIG. 212
( SEE NOTE 3 ) OR EQUAL

FOR BOLTED CONNECTION,


12
USE (4) 5/8 " DIA. A325 BOLTS
C/W NUTS & LOCK WASHERS
5
IF ANCHORED TO STEEL OR
(4) 5/8 " DIA. x 5" LONG HILTI
HIT HY 150 ADHESIVE ANCHORS
IF ANCHORED TO CONCRETE
(SEE NOTE 6 & 7.)
25 25

150

NOTES:
1. THIS ANCHOR IS APPLICABLE TO LINES 3" TO 10" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. ONE OF THE PIPE CLAMPS SHALL BE FITTED WITH SHEAR LUGS.

4. SIZE BOLT HOLES IN BASE PLATE TO SUIT CONNECTION BOLTS OR ANCHORS. SEE NOTE 7.

5. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY STRUCTURAL ENGINEER.

6. FOR BOLTED CONNECTION MAXIMUM AXIAL LOAD 11.1 kN, MAXIMUM LATERAL LOAD 3.1 kN,
FOR GREATER LOADS CONSULT STRUCTURAL ENGINEER.
SUPPORT SUPPORT
TAG MATERIAL

203B BOLTED/C.S.

203W WELDED/C.S.

7. BOLTS AND ASSOCIATED HARDWARE NOT APPLICABLE WHEN


USED IN CONJUCTION WITH DESIGN STANDARDS DS-PS-DA250 & DS-PS-DA252.

8. RUBBER LINED OR INTERNALLY COATED PIPE SHALL HAVE LUGS SHOP WELDED PRIOR TO
RUBBER LINING OR INTERNAL COATING. ALL OTHER PIPE SHALL HAVE LUGS FIELD WELDED.

9. WELD TO STEEL MEMBER OR FIELD DRILL BASEPLATE TO SUIT CONCRETE ANCHOR DETAIL.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
"GRINNELL" CHG’D TO "ANVIL INTL." DESIGN STANDARD NO. REV.
2 T.G. SUP.
KWIK-BOLTS CHG’D TO HILTI HIT H.LESKIE
10/22/04

3 D.K.
11/18/05
ADDED WELDED OPTION B.C. DATE 03/28/95 DS-PS-A203 3
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA203.DGN
100 SEE
NOTE 8
TYP.
7

OR "H" AS SPEC.
NON-THIN WALL

ON DRAWING

12
S.S, ALLOY OR
RUBBER LINED C.S. PIPE

B.O.P.

100
TYP.
7
12

38x25
INSULATION
TYP. 13 BAND SLOT
6
SEE NOTES TYP.
5 AND 9 125mm FOR ANCHORING TO
MIN. 455
CONCRETE, OR BOLT GAUGE
OR "L" AS SPEC. ON DRAWING
TO SUIT SUPPORT STEEL
25 TYP. (SEE NOTE 7)

(7) SHEAR LUGS


MATERIAL SAME AS PIPE
PIPE CLAMP
(SEE NOTE 3)
ANVIL INTL. FIG. 212
OR EQUAL

FOR BOLTED CONNECTION,


12
USE (4) 5/8 " DIA. A325
TYP TYP
7 BOLTS C/W NUTS & LOCK WASHERS
IF ANCHORED TO STEEL OR
(4) 3/4 " DIA. x 9" LONG HILTI
HIT HY 150 ADHESIVE ANCHORS
IF ANCHORED TO CONCRETE
165
( SEE NOTE 6 & 7)

25 25

305
NOTES:
1. THIS ANCHOR IS APPLICABLE TO LINES 12" TO 18" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. ONE OF THE PIPE CLAMPS SHALL BE FITTED WITH SHEAR LUGS.

4. SIZE BOLT HOLES IN BASE PLATE TO SUIT CONNECTION BOLTS OR ANCHORS. SEE NOTE 7.
5. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.
6. FOR BOLTED CONNECTION MAXIMUM AXIAL LOAD 22.2 kN, MAXIMUM LATERAL LOAD 11.1 kN,
FOR GREATER LOADS CONSULT STRUCTURAL ENGINEER.

7. BOLTS AND ASSOCIATED HARDWARE NOT APPLICABLE WHEN


USED IN CONJUCTION WITH DESIGN STANDARD DS-PS-DA251. SUPPORT SUPPORT
TAG MATERIAL
8. RUBBER LINED OR INTERNALLY COATED PIPE SHALL HAVE LUGS
SHOP WELDED PRIOR TO RUBBER LINING OR INTERNAL COATING.
204B BOLTED/C.S.
ALL OTHER PIPE SHALL HAVE LUGS FIELD WELDED.

9. WELD TO STEEL MEMBER OR FIELD DRILL BASEPLATE TO SUIT 204W WELDED/C.S.


CONCRETE ANCHOR DETAIL.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
2 T.G. "GRINNELL" CHG’D TO "ANVIL INTL." DESIGN STANDARD NO. REV.
SUP. H.LESKIE
10/22/04 HILTI ANCHOR TYPE CHG’D

3 D.K.
11/18/05
ADDED WELDED OPTION B.C. DATE 03/28/95 DS-PS-A204 3
*DATE*TIME* CADD FILE No. PSP108\CAD\PIPE SUPPORT STANDARDS\DSPSA204.DGN
PIPE CLAMP ANVIL INTL. OR EQUAL.
SEE TABLE FOR FIG. No.
SEE NOTE 6
SEE (7) SHEAR LUGS
"B" 100 TYP.
NOTE 7 MATERIAL SAME
TYP
AS PIPE ( SEE NOTE 3 )
7

38

NON-THIN WALL TYP.

TYP.
S.S., ALLOY, OR

OR "H" AS SPEC.
20
RUBBER LINED

ON DRAWING
C.S. PIPE

B.O.P.

12

100
38x25 TYP
INSULATION 7
BAND SLOT

150 150 FOR CONNECTION


INFO SEE NOTES 4 & 5
MIN. 455

OR "L" AS SPEC. ON DWG.

TYP
5 100-165

PIPE ANVIL INTL.


90
"A" "B"
DIA. CLAMP
SEE NOTE 6

20" 305 455 FIG. 212/212S

24" 380 455 FIG. 212/212S

TYP
5 28" 455 660 FIG. 216/216S
"A"
TYP.

30" 510 660 FIG. 216/216S


12

32" 560 660 FIG. 216/216S

36" 610 660 FIG. 216/216S


90

13
TYP.
NOTES:
1. THIS ANCHOR IS APPLICABLE TO LINES 20" TO 36" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. ONE OF THE PIPE CLAMPS SHALL BE FITTED WITH SHEAR LUGS.

4. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

5. WELD TO STEEL MEMBERS OR FIELD DRILL BASEPLATE TO SUIT CONCRETE ANCHOR DETAIL
EXCEPT WHEN USED IN CONJUCTION WITH DESIGN STANDARD DS-PS-DA251.

6. FOR BASE LENGTH EQUAL TO 455 mm, USE "B" AS SHOWN IN TABLE.
OTHERWISE, "B" = "L" (AS SPECIFIED ON DWG.) + CLAMP WIDTH (PER DS-PS-121)
7. RUBBER LINED OR INTERNALLY COATED PIPE SHALL HAVE LUGS SHOP WELDED PRIOR TO
RUBBER LINING OR INTERNAL COATING. ALL OTHER PIPE SHALL HAVE LUGS FIELD WELDED.

SUPPORT SUPPORT
TAG MATERIAL

205 C.S.

205S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
1 C.M. PLASTIC PIPE OPTION REMOVED H.L. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
03/18/96

2 T.G.
10/22/04
"GRINNELL" CHG’D TO "ANVIL INTL." DATE 03/28/95 DS-PS-A205 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA205.DGN
(2) U-BOLTS ANVIL INTL. FIG. No. 137 OR EQUAL
C/W (4) FINISHED HEX NUTS EA.
PIPE
"T" "W"
DIA.

3"-4" 10 50
2 REINFORCING PADS FOR THIN
6"-10" 12 75
WALL AND PLASTIC PIPE ONLY,
PER DESIGN STANDARD DS-PS-S600
W IF SPECIFIED ON DRAWING.

TYP.
25

(2) SHEAR LUGS FOR


METAL PIPE ONLY,
MATERIAL SAME AS PIPE,
( SEE NOTE 2 )

PIPE ROD MAX. LATERAL


SIZE SIZE LOAD (kN)

1/2" - 1" 1/4" 0.6

1 1/4" - 2" 3/8" 1.6

2 1/2" - 4" 1/2" 3.0

6" - 8" 5/8" 4.8

10" 3/4" 7.1


SEE
NOTE 2 12" 7/8" 10.0

"T" 5

NOTES:
1. THIS SUPPORT IS APPLICABLE TO LINES 12" AND SMALLER ONLY.

2. FOR RUBBER LINED OR INTERNALLY COATED PIPE, SHEAR LUGS SHALL BE SHOP WELDED
TO BOTTOM OF PIPE OR WEAR PAD PRIOR TO RUBBER LINING OR INTERNAL COATING.
NON RUBBER LINED OR NON COATED METAL PIPES SHALL BE FIELD WELDED.

3. SUPPORT STEEL MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

SUPPORT SUPPORT
TAG MATERIAL

209 C.S.

209S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600, DS-PS-S601
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
1 T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

2 D.K.
11/23/05
REPAD DETAIL MODIFIED B.C. DATE 03/28/95 DS-PS-A209 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA209.DGN
(8) SHEAR LUGS TO BE
WELDED TO PIPE AFTER
CLAMP INSTALLATION
(MATERIAL SAME AS PIPE)

"A"

"
"T
SUPPORT FIG. 609 OR 609S

"W
SEE DESIGN STANDARD

"
DS-PS-S609

SPECIFIED ON DRAWING

STD. WT. PIPE


"L"

6
"C"
6mm dia. VENT HOLE

BASE PLATE PER DESIGN


6
STANDARD DS-PS-X756
IF SPECIFIED ON DRAWING

GROUT

CONCRETE PEDESTAL
WHERE APPLICABLE

PIPE "L" SHEAR LUG SIZE BASE PLATE MAX LAT.


"C"
DIA. MAX. "W" x "T" x "A" SIZE LOAD (kN)

3" - 4" 2" 610 20x20x50 TYPE 1 3.1

6" 3" 910 25x20x75 " 4.0

8" 4" 910 32x20x75 " 4.9

10" - 12" 4" 910 38x20x75 TYPE 2 9.3

14" 6" 910 45x20x75 " 12.2

16" 6" 910 50x35x100 " 12.2

18" 6" 910 50x35x100 " 12.2

NOTES:

1. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

SUPPORT SUPPORT
TAG MATERIAL

210 C.S.

210S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S609, DS-PS-X756
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-A210 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA210.DGN
REINFORCING PAD PER
DESIGN STANDARD
DS-PS-S600 OR DS-PS-S602
FOR S.S. OR ALLOY PIPE ONLY
IF SPECIFIED ON DRAWING.

SEE
NOTE 2

ON DRAWING
SPECIFIED
7
STD. WT. PIPE
"L"

"C"
6mm dia. VENT HOLE

BASE PLATE PER DESIGN


STANDARD DS-PS-X756
IF SPECIFIED ON DRAWING
7

GROUT

CONCRETE PEDESTAL
WHERE APPLICABLE

MAX. LATERAL
PIPE "L"
"C" LOAD BASE PLATE
SIZE MAX.
(kN)

2" & DN SAME AS PIPE 610 3.1

3" 3" 610 4.0 TYPE 1

4" - 6" 4" 910 4.9

8" - 10" 6" 910 11.1 TYPE 2

NOTES:

1. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

2. FOR RUBBER LINED OR INTERNALLY COATED PIPE, ALL WELDING SHALL BE PERFORMED
PRIOR TO RUBBER LINING AND INTERNAL COATING.

SUPPORT SUPPORT
TAG MATERIAL

211 C.S.

211S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600, DS-PS-S602, DS-PS-X756
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

2 D.K.
11/23/05
REPAD DETAIL MODIFIED B.C. DATE 03/28/95 DS-PS-A211 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA211.DGN
METAL

PIPE

ANGLE "A"

TYP
"T"

100 MIN.

STEEL WIDTH

REINFORCING PAD PER


DESIGN STANDARD
DS-PS-S600 IF
SPECIFIED ON DRAWING

PIPE WELD
ANGLE SIZE "A"
DIA. "T"

2"-4" L25x25x4.8x150mm LG. 5

6"-8" L38x38x6.4x150mm LG. 5

10"-12" L51x51x6.4x200mm LG. 7

14"-16" L76x76x9.5x200mm LG. 7

18"-20" L102x102x9.5x255mm LG. 7

22"-26" L127x127x9.5x255mm LG. 9

28"-32" L152x152x9.5x255mm LG. 9

NOTES:
1. THIS ANCHOR IS APPLICABLE TO UNINSULATED LINES 2" TO 32" ONLY.
2. SUPPORT STEEL MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

3. THIS ANCHOR IS NOT SUITABLE FOR RUBBER LINED OR INTERNALLY COATED PIPE.

SUPPORT SUPPORT
TAG MATERIAL

212 C.S.

212S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-A212 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA212.DGN
BUTT WELD & GRIND
TYP. INTERNAL SURFACE SMOOTH
5

PLASTIC PIPE CLAMPS (2)


PIPE ANVIL INTL. FIG.432
OR EQUAL
SEE NOTE 3

120^

3x510
12mm PLATE RUBBER PAD
SEE NOTES 4 & 5
BOTH SIDES

MIN.
TYP.

13
10
TYP.
6mm PLATE 5

12mm PLATE

100 0
TYP. TYP.

BUTT WELD & GRIND


TYP. INTERNAL SURFACE SMOOTH
5

PLASTIC PIPE CLAMPS (2)


PIPE ANVIL INTL. FIG.432
OR EQUAL
SEE NOTE 3

120^

3x510

150 MAX
RUBBER PAD
SEE NOTES 4 & 5

12mm PLATE TYP.


BOTH SIDES 10

6mm PLATE

MIN.
TYP.

6
5

12mm PLATE

100 305 0
TYP. MAX. TYP.

NOTES

1. THIS ANCHOR IS APPLICABLE TO LINES 6" TO 12" SUPPORTED ON STEEL OR ON CONCRETE


PIERS OR SLEEPERS WITH EMBEDDED PLATES.
2. CONCRETE OR STEEL SUPPORT MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.
3. DESIGNER TO REFER TO STANDARD DS-PS-126 FOR CLAMP DIMENSIONS.

4. CLAMP RUBBER PAD AND PIPE TIGHT.


5. WHERE CLAMP OVERLAPS BUTT FUSION WELD BEAD, EXTERNAL BEAD IS TO BE REMOVED
PER MANUFACTURERS INSTRUCTIONS.

SUPPORT SUPPORT
TAG MATERIAL

A214 C.S.

A214S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-126
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

DATE 03/28/95 DS-PS-A214 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA214.DGN
BUTT WELD & GRIND
INTERNAL SURFACE SMOOTH

TYP. TYP.
10
5 PIPE CLAMPS (2)
PLASTIC ANVIL INTL. FIG.432
PIPE OR EQUAL
SEE NOTE 3

120^

TYP.
200

3x660
RUBBER PAD
SEE NOTES 4 & 5

HP 200x53

MIN.
13
16mm PLATE TYP.
BOTH SIDES 7
16mm PLATE

150 0
TYP. TYP.

BUTT WELD & GRIND


TYP. INTERNAL SURFACE SMOOTH
5

PLASTIC PIPE CLAMPS (2)


PIPE ANVIL INTL. FIG.432
OR EQUAL
SEE NOTE 3

120^

3x660
RUBBER PAD
MAX.
200

SEE NOTES 4 & 5

TYP.
10
12

MIN.
HP 200 x 53

6
16mm PLATE 16mm PLATE TYP.
BOTH SIDES 7

150 305 0
TYP. (MAX.) TYP.

NOTES

1. THIS ANCHOR IS APPLICABLE TO LINES 14" TO 24" SUPPORTED ON STEEL OR ON CONCRETE

PIERS OR SLEEPERS WITH EMBEDDED PLATES.


2. CONCRETE OR STEEL SUPPORT MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.
3. DESIGNER TO REFER TO STANDARD DS-PS-126 FOR CLAMP DIMENSIONS.
4. CLAMP RUBBER PAD AND PIPE TIGHT.
5. WHERE CLAMP OVERLAPS BUTT FUSION WELD BEAD, EXTERNAL BEAD IS TO BE REMOVED
PER MANUFACTURERS INSTRUCTIONS.

SUPPORT SUPPORT
TAG MATERIAL

A215 C.S.

A215S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-126
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

DATE 03/28/95 DS-PS-A215 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA215.DGN
3mm THK. RUBBER BUTTWELD & GRIND
PAD AROUND PLASTIC INTERNAL SURFACE SMOOTH

OR "H" AS SPEC.
PIPE
( SEE NOTE 3 )

ON DRAWING
PLASTIC PIPE

100
12
TYP.

12
TYP.
5

38x25
12mm PLATE INSULATION
BAND SLOT

12
TYP.

50mm FOR ANCHORING TO


3" dia. & 4" dia. = 255mm CONCRETE, OR BOLT GAUGE
6" dia. - 12" dia. = 405mm TO SUIT SUPPORT STEEL

(2) PIPE CLAMPS


ANVIL INTL. FIG. 432
OR EQUAL
SEE NOTE 7

12
USE (4) 5/8" DIA. A325 BOLTS
C/W NUTS & LOCK WASHERS
5
IF ANCHORED TO STEEL OR
(4) 5/8" DIA. x 5"
KWIK-BOLTS IF
ANCHORED TO CONCRETE
SEE NOTE 6
25 25

150
NOTES:
1. THIS ANCHOR IS APPLICABLE TO LINES 3" TO 12" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. CLAMP RUBBER PAD AND PIPE TIGHT.
4. SIZE BOLT HOLES IN BASE PLATE TO SUIT CONNECTION
BOLTS OR ANCHORS.
5. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED
BY STRUCTURAL ENGINEER
6. THESE ATTACHMENTS ARE FOR MAXIMUM AXIAL LOAD 11.1 kN, MAXIMUM LATERAL
LOAD 3.1 kN. FOR GREATER LOADS CONSULT STRUCTURAL ENGINEER.
7. DESIGNER TO REFER TO STANDARD DS-PS-126 FOR CLAMP DIMENSIONS.
8. WHERE CLAMP OVERLAPS BUTT FUSION WELD BEAD, EXTERNAL BEAD IS TO BE REMOVED
PER MANUFACTURERS INSTRUCTIONS.

SUPPORT SUPPORT
TAG MATERIAL

216 C.S.

216S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-126
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

DATE 03/28/95 DS-PS-A216 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA216.DGN
BUTTWELD &
GRIND INTERNAL
SURFACE SMOOTH

OR "H" AS SPEC.
PLASTIC PIPE

ON DRAWING
7
100
TYP.
7

12

12mm PLATE (TYP.)

3x660 RUBBER 38x25


PAD AROUND INSULATION
PLASTIC PIPE BAND SLOT
(SEE NOTES 3 & 8)
12
TYP.
455 125mm FOR ANCHORING TO
CONCRETE, OR BOLT GAUGE
TO SUIT SUPPORT STEEL

(2) PIPE CLAMPS


ANVIL INTL. FIG. 432
OR EQUAL
SEE NOTE 7

12
USE (4) 5/8" DIA. A325
TYP TYP
7 BOLTS C/W NUTS & LOCK WASHERS
IF ANCHORED TO STEEL OR
(4) HILTI HVA M20 x 240 (3/4" dia. )
IF ANCHORED TO CONCRETE
SEE NOTE 6
165

25 25

305
NOTES:
1. THIS ANCHOR IS APPLICABLE TO LINES 14" TO 18" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. CLAMP RUBBER PAD AND PIPE TIGHT.
4. SIZE BOLT HOLES IN BASE PLATE TO SUIT CONNECTION BOLTS OR ANCHORS.
5. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.
6. THESE ATTACHMENTS ARE FOR MAXIMUM AXIAL LOAD 22.2 kN, MAXIMUM LATERAL
LOAD 11.1 kN. FOR GREATER LOADS CONSULT STRUCTURAL ENGINEER.
7. DESIGNER TO REFER TO STANDARD DS-PS-126 FOR CLAMP DIMENSIONS.
8. WHERE CLAMP OVERLAPS BUTT FUSION WELD BEAD, EXTERNAL BEAD IS TO BE REMOVED
PER MANUFACTURERS INSTRUCTIONS.

SUPPORT SUPPORT
TAG MATERIAL

217 C.S.

217S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-126
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

DATE 03/28/95 DS-PS-A217 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA217.DGN
PIPE CLAMPS (2) ANVIL INTL.
3x660 RUBBER PAD
FIG. 432 OR EQUAL.
SEE NOTES 6 & 7
SEE NOTE 3
610 BUTTWELD & GRIND
INTERNAL SURFACE
SMOOTH

38

TYP.

TYP.

OR "H" AS SPEC.
20

ON DRAWING
PLASTIC PIPE

12

100
12mm PLATE
(TYP.)
7
38x25 TYP
INSULATION 7
BAND SLOT

150 150 FOR CONNECTION


INFO SEE NOTES 5
455

5
TYP
5 100-230

PIPE
90
"A"
DIA.

20" 305

24" 380
5
SEE TABLE

TYP
5
"A"
TYP.
12

90

12
TYP.

NOTES:
1. THIS ANCHOR IS APPLICABLE TO LINES 20" TO 24" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. DESIGNER TO REFER TO STANDARD DS-PS-126 FOR CLAMP DIMENSIONS.
4. SUPPORT STEEL OR CONCRETE MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.
5. WELD TO STEEL MEMBERS OR FIELD DRILL BASEPLATE TO SUIT CONCRETE ANCHOR DETAIL.
6. WHERE CLAMP OVERLAPS BUTT FUSION WELD BEAD, EXTERNAL BEAD IS TO BE REMOVED
PER MANUFACTURERS INSTRUCTIONS.
7. CLAMP RUBBER PAD AND PIPE TIGHT.

SUPPORT SUPPORT
TAG MATERIAL

218 C.S.

218S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-126
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. ANCHOR
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

DATE 03/28/95 DS-PS-A218 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSA218.DGN
METAL PIPE

REINFORCING PAD
PER DESIGN STANDARD
DS-PS-S600 IF

MIN.
SPECIFIED ON DRAWING

13
TYP.
7
WT100x23 (8" TO 10" LINES)
GAP "G" = 1.6mm (TYP.) WT75x11 (3" TO 6" LINES)
OR AS SPECIFIED
ON DRAWING.

METAL OR
PLASTIC
PIPE

PIPE SHOE PER DESIGN


STANDARD DS-PS-S603
OR DS-PS-A203 AS
SPECIFIED ON DRAWING

MIN.
13
TYP.
7
WT100x23 (8" TO 10" LINES)
GAP "G" = 1.6mm (TYP.) WT75x11 (3" TO 6" LINES)
OR AS SPECIFIED
ON DRAWING.

NOTES

1. THIS DIRECTIONAL ANCHOR IS APPLICABLE TO LINES 3" TO 10" SUPPORTED ON STEEL ONLY.
2. SUPPORT STEEL MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

SUPPORT SUPPORT
TAG MATERIAL

250 C.S.

250S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S603, DS-PS-A203
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. DIRECTIONAL ANCHOR
1 T.G. WT SIZES & GAP REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

2 T.G.
10/22/04
REF. STANDARDS ADDED DATE 03/28/95 DS-PS-DA250 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSDA250.DGN
METAL
PIPE

REINFORCING PAD
PER DESIGN STANDARD
DS-PS-S600 IF
SPECIFIED ON DRAWING

MIN.
13
150 HP200x54
TYP. 230
TYP.
12mm PLATE 7

GAP "G" = 1.6mm (TYP.) TYP.


OR AS SPECIFIED 7

ON DRAWING.

METAL OR
PLASTIC
PIPE

PIPE SHOE PER DESIGN


STANDARD DS-PS-S604/S605
OR DS-PS-A204/A205 AS
SPECIFIED ON DRAWING

MIN.
13
HP200x54 230
TYP.
150 12mm PLATE 7

TYP. TYP.
GAP "G" = 1.6mm (TYP.)
7
OR AS SPECIFIED
ON DRAWING.

NOTES

1. THIS DIRECTIONAL ANCHOR IS APPLICABLE TO LINES 12" TO 36"


SUPPORTED ON STEEL ONLY.
2. SUPPORT STEEL MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

SUPPORT SUPPORT
TAG MATERIAL

251 C.S.

251S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600, DS-PS-S604/S605, DS-PS-A204/A205
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. DIRECTIONAL ANCHOR
1 T.G. LENGTH ADDED FOR HP8 Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

2 T.G.
10/22/04
REF. STANDARDS ADDED DATE 03/28/95 DS-PS-DA251 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSDA251.DGN
METAL PIPE

150 MAX.
REINFORCING PAD
PER DESIGN STANDARD
DS-PS-S600 IF
SPECIFIED ON DRAWING

MIN.
6
WT100x23 (8" & 10" LINES)
WT75x11 (3" TO 6" LINES)

GAP "G" = 1.6mm (TYP.)


TYP.
OR AS SPECIFIED
7
ON DRAWING.

METAL OR
PLASTIC
PIPE

150 MAX.
PIPE SHOE PER DESIGN
STANDARD DS-PS-S603
OR DS-PS-A203 AS
SPECIFIED ON DRAWING

MIN.
6
WT100x23 (8" & 10" LINES)
WT75x11 (3" TO 6" LINES)

GAP "G" = 1.6mm (TYP.) TYP.


OR AS SPECIFIED 7
ON DRAWING.

NOTES

1. THIS DIRECTIONAL ANCHOR IS APPLICABLE TO LINES 3" TO 10" SUPPORTED ON CONCRETE


PIERS, WALLS OR SLEEPERS ONLY.
2. CONCRETE SUPPORT MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

SUPPORT SUPPORT
TAG MATERIAL

252 C.S.

252S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600, DS-PS-S603, DS-PS-A203
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. DIRECTIONAL ANCHOR
1 T.G. WT SIZES & GAP REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

2 T.G.
10/22/04
REF. STANDARDS ADDED DATE 03/28/95 DS-PS-DA252 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSDA252.DGN
PIPE SUPPORT AS
SPECIFIED ON
DRAWING

C.S. PLATE
12x22x150 LG
ASTM A36

WT75x15, 50mm LG
C.S. ASTM A36

12
7
5

1.6

TYP.

NOTES:
1. SUPPORT STEEL MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.
2. THIS GUIDE CAN BE APPLIED TO THE FOLLOWING SUPPORT STANDARDS:
- DS-PS-S603 - DS-PS-S606
- DS-PS-S604 - DS-PS-S607
- DS-PS-S605 - DS-PS-S608

SUPPORT SUPPORT
TAG MATERIAL

300 C.S.

300S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S603/S604/S605, DS-PS-606/S607/S608
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. GUIDE
1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-G300 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSG300.DGN
U-BOLT ANVIL INTL.
FIG. 137 OR EQUAL

3mm GAP ALL AROUND

"
"D
REINFORCING PAD
PER DESIGN STANDARD
DS-PS-S600
FOR THIN WALL ONLY

NOM. ALTERNATE
ROD SIZE
PIPE
"B"
DIA. "D"

1/2" 3/8"
3/4" 3/8"
1" 3/8"
1 1/4" 3/8"
1 1/2" 3/8"
2" 3/8"
2 1/2" 1/2"

3" 1/2"
4" 1/2"
5" 1/2"
6" 5/8"
8" 5/8"
10" 3/4"
12" 7/8"
14" 7/8"
16" 7/8"
18" 1" DO NOT USE
20" 1" WITHOUT PERMISSION
OF STRESS ENGINEER
22" 1"
24" 1"

NOTES:

1. U-BOLTS SHOULD NOT BE CLAMPED TIGHT AT THE PIPE.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. GUIDE
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
2 SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

3 D.K.
11/18/05
ADDED ADDITIONAL SIZE B.C. DATE 03/28/95 DS-PS-G302 3
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSG302.DGN
REINFORCING PADS 305mm dia.
OR 255mm SQUARE FOR
CONNECTION TO TANK WALL
MATERIAL & THICKNESS
TO MATCH TANK TANK SUPPORT STEEL

"T" 50-125

TYP.
"W" 30^ 30^
1830 MAX.

3mm dia. VENT


HOLE (TYP.)

STD. WT. PIPE


TYP. DIA. "D"
"W"

LOOSE FIT TO PERMIT

PIPE SPACER PIPE MOVEMENT

PIPE CLAMP ANVIL INTL.

"T"= TANK WALL THK. FIG. 212 OR EQUAL


SEE NOTE 2

"W"= PIPE "D"


WALL THK.
REINFORCING PADS
PER DESIGN STANDARD
NOMINAL PIPE
DS-PS-S615 FOR
PIPE SIZE "D"
PLASTIC PIPE ONLY
2 1/2" 1"

3" 1"

4" 1"

6" 1 1/2"

8" 2"

10" 3"

12" 3"

14" 4"

16" 4"

18" 4"

20" 4"

24" 4"

NOTES

1. SPECIFY C
ELEVATION OF SWAY BRACE ON SUPPORT DWG.
2. (2) PIPE CLAMPS ANVIL INTL. FIG. 212 OR EQUAL SHALL BE WELDED TOGETHER
(INTERMITTENT WELD) TO SUIT PIPE "D" FOR NOMINAL PIPE SIZE 8" & ABOVE.
3. SUPPORT STEEL MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

SUPPORT SUPPORT
TAG MATERIAL

303 C.S.

303S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S603/S604/S605, DS-PS-S606/S607/S608
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. GUIDE
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

DATE 03/28/95 DS-PS-G303 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSG303.DGN
1.6

50

AS SHOWN
ON DWG.
"L"
REINFORCING PAD PER
SUPPORT SHOE IF SPECIFIED ON DWG.
DESIGN STANDARD DS-PS-600
IF SPECIFIED ON DRAWING

TEE SHAPE
"T" WELDED ’W’
SHAPE
(SEE NOTE 2.) 5

STANDARD ALTERNATE

TEE
PIPE
SHAPE
SIZE
"T"

10" & DN WT75x15

12" - 24" WT100x23

26" - 36" WT155x37

NOTES:
1. SUPPORT STEEL MUST BE REVIEWED BY THE STRUCTURAL ENGINEER.

2. WHERE SPACE BETWEEN ADJACENT PIPES, OR WIDTH OF SUPPORT STEEL


DOES NOT ALLOW FOR ADEQUATE WELDING OF 2 STAGGERED GUIDE TEES,
THE AFFECTED TEES SHALL BE REPLACED BY A FABRICATED ’W’ SECTION OF
EQUIVALENT FLANGE WIDTH AND THICKNESS.

SUPPORT SUPPORT
TAG MATERIAL

306 C.S.

306S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. GUIDE
3 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

4 D.K.
11/18/05
HEIGHT DIM. ADDED B.C. DATE 03/28/95 DS-PS-G306 4
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSG306.DGN
HANGER DATA

WELD LENGTH AND SIZE FOR CORRESPONDING ROD DIAMETERS


FOR UPPER HANGER ASSEMBLY.

HANGER LENGTH SIZE OF

ROD OF WELD FILLET "W"

DIA. "L" MIN. MAX.

3/8 20 3 7

1/2 20 3 7

5/8 20 5 7

3/4 20 7 10

7/8 32 7 10

1 32 10 13

1 1/8 32 10 13

1 1/4 32 13 16

1 1/2 38 16 20

1 3/4 57 16 20

2 57 20 20

2 1/4 70 20 20

2 1/2 83 20 20

2 3/4 155 16 20

3 155 16 20

3 1/4 178 20 25

3 1/2 178 20 25

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
Pe
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. HANGER ASSEMBLY NOTES
1 J.H. RODS & NUTS ADDED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

2 T.G.
10/22/04
REF. STANDARDS ADDED
"GRINNELL" CHG’D TO "ANVIL INTL."
DATE 03/28/95 DS-PS-H400 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSH400.DGN
SEE NOTE 6

"L"

BOTTOM OF STEEL SEE NOTE 6


OR CONCRETE "W"

HANGER PLATE WELDED ATTACHMENT ANVIL INTL.


PER DS-PS-X758 FIG. 66 OR EQUAL
IF SPEC. ON DWG.

"H" AS SHOWN IN DRAWING WELDLESS EYE NUT ANVIL INTL.


FIG. 290 OR EQUAL

FOR ROD LENGTHS GREATER THAN 3m,


ADD TURNBUCKLE ANVIL INTL. FIG. 230
OR EQUAL c/w 2 LOCK NUTS.
SIZE TO MATCH ROD DIAMETER OF UPPER &
LOWER HANGER ASSEMBLY.

HANGER ROD DIA. PER TABLES


ON DESIGN STANDARD DS-PS-121.
c/w LOCK NUTS.

WELDLESS EYE NUT ANVIL INTL.


FIG. 290 OR EQUAL

REINFORCING PADS PER


DESIGN STANDARD
DS-PS-S615 FOR
ALL PLASTIC LINES

PIPE CLAMP ( SEE NOTE 1 )


MODERATE LOADS: ANVIL INTL.
FIG. 212 OR EQUAL
HEAVY LOADS: ANVIL INTL.
FIG. 216 OR EQUAL

NOTES:

1. DESIGNER TO REFER TO DESIGN STANDARD DS-PS-113 & DS-PS-121 FOR ROD & CLAMP CAPACITIES.
2. FIELD SELECTION OF PIPE CLAMPS TO BE MADE PER HANGER SPACING TABLES
IN PIPE SUPPORT SPECIFICATION.
3. WHEN WELDING TO U/S OF A LOAD BEAM, THE WELDING BEAD "W" SHOULD ALWAYS BE
APPLIED TO A DIRECTION PARALLEL TO THE BEAM’S LONGITUDINAL CENTERLINE.
4. THIS STANDARD APPLIES TO UNINSULATED LINES ONLY.
5. ROD AND HANGER COMPONENTS SHALL BE THE SAME MATERIAL.
6. DESIGNER TO REFER TO DESIGN STANDARD DS-PS-H400 FOR ROD AND WELD SIZES.

ANVIL INTL. PIPE


SUPPORT
CLAMP TYPE OR EQ.
TAG
/ MATERIAL

410A FIG. 212 / C.S.

410B FIG. 216 / C.S.

410AS FIG. 212 / 316 S.S.

410BS FIG. 216 / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-113/121, DS-PS-S614/S615, DS-PS-X758,DS-PS-H400
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. HANGER ASSEMBLY
1 J.H. RODS & NUTS DELETED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

2 T.G.
10/22/04
REF. STANDARDS ADDED
"GRINNELL" CHG’D TO "ANVIL INTL."
DATE 03/28/95 DS-PS-H410 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSH410.DGN
SEE NOTE 6

"L"

BOTTOM OF STEEL SEE NOTE 6


OR CONCRETE "W"

HANGER PLATE WELDED ATTACHMENT ANVIL INTL.


PER DS-PS-X758 FIG. 66 OR EQUAL
IF SPEC. ON DWG.

WELDLESS EYE NUT ANVIL INTL.


FIG. 290 OR EQUAL

"H" AS SHOWN IN DRAWING FOR ROD LENGTHS GREATER THAN 3m,


ADD TURNBUCKLE ANVIL INTL. FIG. 230
OR EQUAL c/w 2 LOCK NUTS.
SIZE TO MATCH ROD DIAMETER OF UPPER &
LOWER HANGER ASSEMBLY.

HANGER ROD DIA. PER TABLES


ON DESIGN STANDARD DS-PS-122.
c/w LOCK NUTS.

WELDLESS EYE NUT ANVIL INTL.


FIG. 290 OR EQUAL

REINFORCING PADS PER


DESIGN STANDARDS
DS-PS-S614 OR DS-PS-S615
FOR THIN WALL PIPE WITH
CLAMP WIDTHS < 4" AND ALL
PLASTIC LINES

PIPE CLAMP ( SEE NOTE 1 )


MODERATE LOADS: ANVIL INTL.
FIG. 295 OR EQUAL
HEAVY LOADS: ANVIL INTL.
FIG. 295H OR EQUAL

NOTES:

1. DESIGNER TO REFER TO DESIGN STANDARD DS-PS-113 & DS-PS-122 FOR ROD & CLAMP CAPACITIES.
2. FIELD SELECTION OF PIPE CLAMPS TO BE MADE PER HANGER SPACING TABLES
IN PIPE SUPPORT SPECIFICATION.
3. WHEN WELDING TO U/S OF A LOAD BEAM, THE WELDING BEAD "W" SHOULD ALWAYS BE
APPLIED TO A DIRECTION PARALLEL TO THE BEAM’S LONGITUDINAL CENTERLINE.
4. THIS STANDARD APPLIES TO UNINSULATED LINES ONLY.
5. ROD AND HANGER COMPONENTS SHALL BE THE SAME MATERIAL.
6. DESIGNER TO REFER TO DESIGN STANDARD DS-PS-H400 FOR ROD AND WELD SIZES.

ANVIL INTL. PIPE


SUPPORT
CLAMP TYPE OR EQ.
TAG
/ MATERIAL

411A FIG. 295 / C.S.

411B FIG. 295H / C.S.

411AS FIG. 295 / 316 S.S.

411BS FIG. 295H / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-113/122, DS-PS-S614/S615, DS-PS-X758,DS-PS-H400
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. HANGER ASSEMBLY
1 J.H. RODS & NUTS DELETED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

2 T.G.
10/22/04
REF. STANDARDS ADDED
"GRINNELL" CHG’D TO "ANVIL INTL."
DATE 03/28/95 DS-PS-H411 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSH411.DGN
SEE NOTE 4 SEE NOTE 4

"L" "L"

BOTTOM OF STEEL OR CONCRETE

SEE HANGER PLATE PER DS-PS-X758


NOTE 4 IF SPEC. ON DWG.
"W"

HANGER RODS, DIA. PER TABLES


ON DESIGN STANDARD DS-PS-125
c/w LOCK NUTS.
"H" AS SHOWN IN DRAWING

SIZE OF ROD DIAMETER TO MATCH


UPPER & LOWER HANGER ASSEMBLY.

FOR ROD LENGTHS GREATER THAN 3m,


ADD TURNBUCKLE ANVIL INTL. FIG. 230
OR EQUAL c/w 2 LOCK NUTS.

REINFORCING PADS PER


DESIGN STANDARD DS-PS-600
FOR THIN WALL ONLY
LENGTH "B" TO SUIT
IF SPECIFIED ON DRAWING
50 MIN.

WELDLESS EYE NUT ANVIL INTL.


FIG. 290 OR EQUAL

C EL. SPECIFIED
ON PLAN
50 MIN.

DOUBLE RISER CLAMP


ANVIL INTL. FIG. 40/40SD OR EQUAL
C/W SHEAR LUGS
SEE NOTE 1

NOTES:
1. DESIGNER TO REFER TO DESIGN STANDARDS DS-PS-113, DS-PS-123 AND DS-PS-125
FOR ROD, CLAMP AND SHEAR LUG CAPACITIES AND DIMENSIONS.

2. WHEN WELDING TO U/S OF A LOAD BEAM, THE WELDING BEAD "W" SHOULD ALWAYS BE
APPLIED TO A DIRECTION PARALLEL TO THE BEAM’S LONGITUDINAL CENTERLINE.

3. ROD AND HANGER COMPONENTS SHALL BE THE SAME MATERIAL.


4. DESIGNER TO REFER TO DESIGN STANDARD DS-PS-H400 FOR ROD AND WELD SIZES.

RISER CLAMP
SUPPORT
TYPE ( SEE NOTES )
TAG
/ MATERIAL

414A FIG. 414A / C.S.

414B FIG. 414B / C.S.

414C FIG. 414C / C.S.

414D FIG. 414D / C.S.

414AS FIG. 414A / 316 S.S.

414BS FIG. 414B / 316 S.S.

414CS FIG. 414C / 316 S.S.

414DS FIG. 414D / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-113/123/125, DS-PS-S600, DS-PS-H400
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. HANGER ASSEMBLY
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
2 SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

3 D.K.
11/23/05
REVISED REPAD DETAIL B.C. DATE 03/28/95 DS-PS-H414 3
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSH414.DGN
SEE NOTE 6 SEE NOTE 6

"L" "L"

BOTTOM OF STEEL OR CONCRETE

HANGER PLATE PER DS-PS-X758


"W" SEE
IF SPEC. ON DWG.
"W" NOTE 6

HANGER ROD, 50 DIA.


c/w LOCK NUTS.
"H" AS SHOWN IN DRAWING

SIZE OF ROD DIAMETER TO MATCH


UPPER & LOWER HANGER ASSEMBLY.

FOR ROD LENGTHS GREATER THAN 3m,


ADD TURNBUCKLE ANVIL INTL. FIG. 230
OR EQUAL c/w 2 LOCK NUTS.

STEEL CLEVIS ANVIL INTL.


FIG. 299 OR EQUAL

C EL. SPECIFIED
ON PLAN

WELDING LUG ANVIL INTL.


FIG. 55 OR EQUAL

REINFORCING PAD PER


DESIGN STANDARD
DS-PS-S600

NOTES:
1. THIS HANGER ASSEMBLY IS TO BE USED ONLY FOR LINES 4" dia. AND LESS.
2. REFER TO ANVIL INTL. CATALOG FOR MAXIMUM RECOMMENDED LOADS.
3. WHEN WELDING TO U/S OF A LOAD BEAM, THE WELDING BEAD "W" SHOULD ALWAYS BE
APPLIED TO A DIRECTION PARALLEL TO THE BEAM’S LONGITUDINAL CENTERLINE.

4. ROD AND HANGER COMPONENTS SHALL BE THE SAME MATERIAL.


5. DESIGNER TO REFER TO DESIGN STANDARD DS-PS-113 FOR ROD CAPACITIES.
6. DESIGNER TO REFER TO DESIGN STANDARD DS-PS-H400 FOR ROD AND WELD SIZES.

SUPPORT HANGER
TAG MATERIAL

416 C.S.

416S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600, DS-PS-113, DS-PS-H400
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. HANGER ASSEMBLY
1 J.H. RODS & NUTS DELETED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

2 T.G.
10/22/04
REF. STANDARDS ADDED
"GRINNELL" CHG’D TO "ANVIL INTL."
DATE 03/28/95 DS-PS-H416 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSH416.DGN
SEE NOTE 6

"L"
BOTTOM OF STEEL
OR CONCRETE

HANGER PLATE PER DS-PS-X758


IF SPEC. ON DWG.

"W"

WELDED ATTACHMENT ANVIL INTL.


FIG. 66 OR EQUAL

WELDLESS EYE NUT ANVIL INTL.


FIG. 290 OR EQUAL

FOR ROD LENGTHS GREATER THAN 3m,

"H" AS SHOWN IN DRAWING


ADD TURNBUCKLE ANVIL INTL. FIG. 230
OR EQUAL c/w 2 LOCK NUTS.
SIZE TO MATCH ROD DIAMETER OF UPPER &
LOWER HANGER ASSEMBLY.

HANGER ROD, DIA. "A"


PER TABLE. c/w LOCK NUTS

ADJUSTABLE CLEVIS
ANVIL INTL. FIG. 260 OR EQUAL

NOM. ROD BOLT CAPACITY LENGTH SIZE OF


PIPE DIA. DIA. IN OF WELD FILLET"W"
DIA. "A" "B" kN "L"
MIN. MAX.

"B"
3/4" 3/8" 1/4" 2.7 20 3 7

1" 3/8" 1/4" 2.7 20 3 7

1 1/2" 3/8" 1/4" 2.7 20 3 7

2" 3/8" 1/4" 2.7 20 3 7

2 1/2" 1/2" 3/8" 5.0 20 3 7

3" 1/2" 3/8" 5.0 20 3 7

4" 5/8" 3/8" 6.3 20 5 7

6" 3/4" 1/2" 8.6 20 7 10

8" 7/8" 5/8" 8.9 32 7 10

10" 7/8" 3/4" 16.0 32 7 10

12" 7/8" 3/4" 16.9 32 7 10 SEE NOTE 1

14" 1" 7/8" 18.6 32 10 13

16" 1" 1" 20.4 32 10 13

18" 1" 1 1/8" 21.3 32 10 13

20" 1 1/4" 1 1/4" 21.3 32 13 16

24" 1 1/4" 1 1/4" 21.3 32 13 16

NOTES:
1. REINFORCING PADS REQUIRED FOR PLASTIC PIPE PER DESIGN STANDARD DS-PS-S601.
2. THIS STANDARD APPLIES TO UNINSULATED LINES ONLY.
3. WHEN WELDING TO U/S OF A LOAD BEAM, THE WELDING BEAD "W" SHOULD ALWAYS BE
APPLIED TO A DIRECTION PARALLEL TO THE BEAM’S LONGITUDINAL CENTERLINE.

4. ROD AND HANGER COMPONENTS SHALL BE THE SAME MATERIAL.

SUPPORT HANGER
TAG MATERIAL

418 C.S.

418S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S601, DS-PS-113, DS-PS-H400
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. HANGER ASSEMBLY
1 J.H. ROD & NUTS DELETED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

2 T.G.
10/22/04
REF. STANDARDS ADDED
"GRINNELL" CHG’D TO "ANVIL INTL."
DATE 03/28/95 DS-PS-H418 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSH418.DGN
FOR 10mm AND

SEE NOTE 2
7 GREATER PLATE
50-125

FOR 6mm PLATE


5 50-125

FOR 3mm PLATE


3 50-125

CARBON
STAINLESS OR
ALLOY PIPE

REINFORCING PAD THICKNESS


SEE NOTE 1

"B" = 455

OR AS SPEC. ON DWG

SUPPORT SUPPORT
TAG MATERIAL
"
"T

S600 C.S.

S600S 316SS
60^ 60^ VENT HOLE
S600A ALLOY
SEE NOTE 4 SEE NOTE 4 SEE NOTE 3

NOTES:

1. REINFORCING PADS SHALL BE MADE FROM THE SAME MATERIAL AND THICKNESS
AS PIPE, SHAPED TO SUIT, O.D. OF PIPE.

2. USE INTERMITTENT FILLET WELDS ON PADS FOR STAINLESS OR ALLOY PIPE.


RUBBER LINED OR INTERNALLY COATED PIPE, LUGS TO BE SHOP WELDED PRIOR TO
RUBBER LINING/INTERNAL COATING. ALL OTHERS TO BE FIELD WELDED.

3. 3mm dia. VENT HOLE IS REQUIRED ONLY WHEN CONTINUOUS FILLET IS APPLIED.
4. PAD ANGLE TO BE 90^ FOR PIPES 4" dia. AND SMALLER.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S601
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. TAG TABLE ADDED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

2 D.K.
11/18/05
PAD THICKNESS REVISED DATE 03/28/95 DS-PS-S600 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS600.DGN
SEE NOTE 2

16^

CARBON,
STAINLESS OR
ALLOY PIPE

EXCEPT AS NOTED FOR 3" AND 4"


PIPE, REINFORCING PADS MAY BE
CUT FROM 45^ ELBOWS
(SEE NOTES 1 & 4)

29^

SUPPORT SUPPORT
TAG MATERIAL

S602 C.S.
"
"T

S602S 316SS

S602A ALLOY 60^ 60^ VENT HOLE

SEE NOTE 4 SEE NOTE 4 SEE NOTE 3

NOTES:

1. REINFORCING PADS SHALL BE MADE FROM THE SAME MATERIAL & WALL THICKNESS
AS PIPE, SHAPED TO SUIT.

2. USE INTERMITTENT FILLET WELDS ON PADS FOR STAINLESS OR ALLOY PIPE.


FILLET WELDS TO BE SAME THICKNESS AS PAD THICKNESS.
RUBBER LINED OR INTERNALLY COATED PIPE, LUGS TO BE SHOP WELDED PRIOR TO
RUBBER LINING/INTERNAL COATING. ALL OTHERS TO BE FIELD WELDED.

3. 3mm dia. VENT HOLE IS REQUIRED ONLY WHEN CONTINUOUS FILLET IS APPLIED.
4. PAD ANGLE TO BE 90^ AND LENGTH 2 x DIA. FOR PIPES 4" dia. AND SMALLER.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. GENERAL REVISION SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-S602 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS602.DGN
REINFORCING PAD PER

OR "H" AS SPEC.
DESIGN STANDARD
DS-PS-S600 FOR

ON DRAWING
THIN WALL ONLY
IF SPECIFIED ON DRAWING.
CARBON STEEL
OR THIN WALL
PIPE

B.O.P.

100

WITH
12
5 REPAD
13
TYP.
TYP
38X25
WITHOUT
5 INSULATION
REPAD
BAND SLOT

455

10 12
5 3 25-50 5 3 25-60
20

20

75 150

IF REQUIRED,
INCLUDE ROD FOR
PIPES 1" TO 4" DIA. PIPES 6" TO 10" DIA.
SLOPED LINES.
SEE NOTE 3

NOTES:
1. THIS SUPPORT IS APPLICABLE TO LINES 1" TO 10" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.

3. ROD SHALL BE SHIPPED LOOSE WITH SHOE.

SUPPORT SUPPORT
TAG MATERIAL

603 C.S.

603R C.S. ROD & SHOE

603S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 WIDTH CHG’D FOR SMALL PIPE SHOE

2 D.K.
11/18/05
C.S. ROD OPTION ADDED B.C. DATE 03/28/95 DS-PS-S603 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS603.DGN
REINFORCING PAD PER
DESIGN STANDARD

OR "H" AS SPEC.
DS-PS-S600 FOR
THIN WALL ONLY

ON DRAWING
CARBON STEEL IF SPECIFIED ON DRAWING.

OR THIN WALL

PIPE

B.O.P.

100

WITH
12
7 REPAD
13
TYP.
TYP
38x25
WITHOUT
7 INSULATION
REPAD
BAND SLOT

455

12

TYP TYP
7 IF REQUIRED,
INCLUDE ROD FOR SLOPED LINES.
SEE NOTE 3
20

175

305

5 25-140

NOTES:
1. THIS SUPPORT IS APPLICABLE TO LINES 12" TO 18" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.

3. ROD SHALL BE SHIPPED LOOSE WITH SHOE.

SUPPORT SUPPORT
TAG MATERIAL

604 C.S.

604R C.S. ROD & SHOE

604S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

2 D.K.
11/18/05
C.S. ROD OPTION ADDED B.C. DATE 03/28/95 DS-PS-S604 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS604.DGN
OR "H" AS SPEC.

ON DRAWING
TYP
CARBON STEEL PIPE 7 150

REINFORCING 38x25 INSULATION

PAD PER BAND SLOT

DS-PS-S600 TYP
7 150

B.O.P.

100
IF REQUIRED,
INCLUDE ROD
FOR SLOPED LINES.

12
SEE NOTE 3

20
"D"

150 150

455

5 "L"-"P"

TYP
5 100-165
90

PIPE
"A" "D" "L" "P"
DIA.

TYP
5 20" 305 485 50 215
"A"
TYP.

24" 380 560 50 255


12

28" 455 635 50 290

30" 510 690 50 320

32" 560 740 75 330


90

36" 610 790 75 350


13
TYP.

NOTES:
1. THIS SUPPORT IS APPLICABLE TO LINES 20" TO 36" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. ROD SHALL BE SHIPPED LOOSE WITH SHOE.

SUPPORT SUPPORT
TAG MATERIAL

605 C.S.

605S 316 S.S.

605R C.S. ROD & SHOE

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

2 D.K.
11/18/05
C.S. ROD OPTION ADDED B.C. DATE 03/28/95 DS-PS-S605 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS605.DGN
6x100 RUBBER

OR "H" AS SPEC.
PAD AROUND PLASTIC
PIPE ONLY

ON DRAWING
( SEE NOTE 3 )

NON-THIN WALL
S.S., ALLOY, PLASTIC,
RUBBER-LINED C.S. OR
INTERNALLY COATED PIPE

100

TYP.
12

5
13
TYP. 38x25
INSULATION
BAND SLOT

455

PIPE CLAMP PIPE CLAMP


ANVIL INTL. FIG. 212 ANVIL INTL. FIG. 212
OR EQUAL OR EQUAL

IF REQUIRED,
10 12 INCLUDE ROD
FOR SLOPED LINES.
3 25-50 5
5 SEE NOTE 4
20

20

75 150

3 25-60
PIPES 1" TO 4" DIA. PIPES 6" TO 10" DIA.

NOTES:
1. THIS SUPPORT IS APPLICABLE TO LINES 1" TO 10" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. CLAMP RUBBER PAD AND PIPE TIGHT.

4. ROD SHALL BE SHIPPED LOOSE WITH SHOE.

SUPPORT SUPPORT
TAG MATERIAL

606 C.S.

606S 316 S.S.

606R C.S. ROD & SHOE

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
T.G. "GRINNELL" CHG’D TO "ANVIL INTL." DESIGN STANDARD NO. REV.
1 SUP. H.LESKIE
10/22/04 WIDTH CHG’D FOR SMALL PIPE SHOE

DATE 03/28/95 DS-PS-S606 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS606.DGN
6x100 RUBBER
PAD AROUND PLASTIC

OR "H" AS SPEC.
PIPE ONLY

NON-THIN WALL ( SEE NOTE 3 )

ON DRAWING
S.S., ALLOY,
PLASTIC,
RUBBER-LINED C.S.,
OR INTERNALLY COATED PIPE

100

TYP.
12

7
13
TYP.
38x25
INSULATION
BAND SLOT

455

PIPE CLAMP
ANVIL INTL. FIG. 212
OR EQUAL
12
TYP TYP
7 IF REQUIRED,
INCLUDE ROD FOR SLOPED LINES.
SEE NOTE 4
20

175

305

5 25-140

NOTES:
1. THIS SUPPORT IS APPLICABLE TO LINES 12" TO 18" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. CLAMP RUBBER PAD AND PIPE TIGHT.

4. ROD SHALL BE SHIPPED LOOSE WITH SHOE.

SUPPORT SUPPORT
TAG MATERIAL

607 C.S.

607S 316 S.S.

607R C.S. ROD & SHOE

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. "GRINNELL" CHG’D TO "ANVIL INTL." SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-S607 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS607.DGN
"B"
6 x "C" RUBBER
PAD AROUND PLASTIC
PIPE ONLY
( SEE NOTE 3 )

NON-THIN WALL

OR "H" AS SPEC.
S.S., ALLOY,

ON DRAWING
PLASTIC,

RUBBER LINED
C.S. OR
INTERNALLY COATED PIPE

B.O.P.

100
IF REQUIRED,
INCLUDE ROD
FOR SLOPED LINES.

12
SEE NOTE 4

20
"D"

38x25 TYP
INSULATION 7
BAND SLOT

150 150
PIPE CLAMP ANVIL INTL. OR EQUAL.
SEE TABLE FOR FIG. No.
455

5 "L"-"P"
TYP
5 100-165
90

PIPE ANVIL INTL.


"A" "B" "C" "D" "L" "P"
DIA. CLAMP

TYP 20" 305 455 100 485 50 215 FIG. 212/212S


5
"A"

24" 380 455 125 560 50 255 FIG. 212/212S


TYP.
12

28" 455 660 255 635 50 290 FIG. 216/216S

30" 510 660 255 690 50 320 FIG. 216/216S

32" 560 660 255 740 75 330 FIG. 216/216S


90

13 36" 610 660 255 790 75 350 FIG. 216/216S

TYP.

NOTES:
1. THIS SUPPORT IS APPLICABLE TO LINES 20" TO 36" ONLY.
2. STAMP SHOE ASSEMBLY TAG NO. IN 6mm HIGH LETTERS IN THE CENTER OF SHOE
13mm FROM TOP EDGE OF PLATE.
3. CLAMP RUBBER PAD AND PIPE TIGHT.

4. ROD SHALL BE SHIPPED LOOSE WITH SHOE.

SUPPORT SUPPORT
TAG MATERIAL

608 C.S.

608S 316 S.S.

608R C.S. ROD & SHOE

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. "GRINNELL" CHG’D TO "ANVIL INTL." SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-S608 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS608.DGN
PIPE CLAMP ANVIL INTL. FIG. 212 OR
EQUAL FOR PIPE SIZE 30" AND UNDER
PIPE CLAMP ANVIL INTL. FIG. 216 OR
EQUAL FOR PIPE SIZE 36"

ROTATE 25^
IF REQUIRED

"D"
CENTER END PLATE

"C"
"B"
PLATE 3
"W"
2

3 2 TEE 1

"A" "T" "E" "F"

TYP.

TEE PLATE PLATE SIZE OF


PIPE SIZE QTY QTY
"A" "B" "C" "D" "E" "F" "T" FILLET
SIZE
1 2 3 "W"

1 1/2" WT 100x13.5 38 89 93 113 - - - - - 5

2" WT 100x13.5 50 89 93 119 - - - - - 5

3" WT 100x13.5 75 89 100 133 - - - - - 5

4" WT 100x13.5 75 89 95 146 - - - - - 5

6" WT 125x16.5 114 100 112 186 - - - - - 5

8" WT 155x30 150 100 120 211 63.5 - 10 1 - 5

10" WT 155x30 175 100 118 238 63.5 - 10 1 - 5

12" WT 155x30 216 100 126 264 63.5 - 10 1 - 5

14" WT 155x30 230 100 127 279 - 125 10 - 2 5

16" WT 155x30 255 100 130 305 - 125 10 - 2 5

18" WT 155x30 280 100 130 330 - 125 10 - 2 7

20" WT 155x30 305 100 133 356 - 125 10 - 2 7

24" WT 155x30 380 100 148 406 63.5 150 10 1 2 7

28" WT 180x32 455 125 164 457 63.5 125 12 1 2 7

30" WT 180x32 510 125 199 508 63.5 125 12 1 2 7

36" WT 180x32 610 125 218 584 63.5 150 12 1 2 7

NOTES:
1. THIS SUPPORT IS NOT TO BE USED BY ITSELF.
USE WITH DS-PS-A208, DS-PS-A210, DS-PS-S610 OR DS-PS-S611 ONLY.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-A208, DS-PS-A210, DS-PS-S610
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

DATE 03/28/95 DS-PS-S609 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS609.DGN
SUPPORT FIG. 609
SEE DESIGN STANDARD
DS-PS-S609

SPECIFIED ON DRAWING
STD. WT. PIPE

"L"
7

"C"

7mm dia. VENT HOLE

BASE PLATE

7
GROUT OR CONCRETE
PEDESTAL WHERE
WEAR PLATE PER APPLICABLE
DESIGN STANDARD
DS-PS-X757 IF
SPECIFIED ON
DRAWING

PIPE "L" BASE WEAR


"C"
SIZE MAX. PLATE PLATE

3" - 4" 2" 610 10x150x150

6" 3" 760 10x150x150


TYPE 1
8" 4" 915 10x230x230

10" - 12" 4" 915 10x230x230

14" 6" 915 12x305x305

16" 6" 915 12x305x305 TYPE 2

18" 6" 915 12x305x305

SUPPORT SUPPORT
TAG MATERIAL

610 C.S.

610S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S609, DS-PS-X757
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. FIELD WELD ADDED H.L. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
05/16/95

2 T.G.
10/22/04
REF. STANDARDS ADDED DATE 03/28/95 DS-PS-S610 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS610.DGN
FLANGE

MATCH FLANGE BOLT DRILLING ON (2)


HOLES FOR ATTACHMENT. CUT TEE TO
SUIT PIPE O.D.
SPECIFIED ON DRAWING
USE TEE AS IN FIG. 609 (EXCEPT
DIM "A"=150mm FOR 3" TO 6" DIA. PIPE)
SEE DESIGN STANDARD
7
DS-PS-S609
"L"

"C" STD. WT. PIPE

7mm dia. VENT HOLE

BASE PLATE
7
GROUT OR CONCRETE
PEDESTAL WHERE
WEAR PLATE PER APPLICABLE
DESIGN STANDARD
DS-PS-X757 IF
SPECIFIED ON
DRAWING

PIPE "L" BASE WEAR


"C"
SIZE MAX. PLATE PLATE

3" - 4" 2" 610 10x150x150

6" 3" 760 10x150x150


TYPE 1
8" 4" 915 10x230x230

10" - 12" 4" 915 10x230x230

14" 6" 915 12x305x305

16" 6" 915 12x305x305 TYPE 2

18" 6" 915 12x305x305

SUPPORT SUPPORT
TAG MATERIAL

611 C.S.

611S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S609, DS-PS-X757
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. FIELD WELD ADDED H.L. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
05/16/95

2 T.G.
10/22/04
REF. STANDARDS ADDED DATE 03/28/95 DS-PS-S611 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS611.DGN
REINFORCING PAD PER
DESIGN STANDARD
7 DS-PS-S602 OR DS-PS-S600
IF SPECIFIED ON DRAWING

ON DRAWING
SPECIFIED
"L" STD. WT. PIPE
"C"

7mm dia. VENT HOLE

BASE PLATE

7
GROUT OR CONCRETE
PEDESTAL WHERE
APPLICABLE
WEAR PLATE PER
DESIGN STANDARD
DS-PS-X757 IF
SPECIFIED ON
DRAWING

PIPE "L" BASE WEAR


"C"
SIZE MAX. PLATE PLATE

3" - 4" 2" 610 10x150x150

6" 3" 760 10x150x150 TYPE 1

8" 4" 915 10x230x230

10" - 12" 4" 915 10x230x230

14" 6" 915 12x305x305

16" 6" 915 12x305x305 TYPE 2

18" 6" 915 12x305x305

20" - 30" 10" 1000 20x425x425 TYPE 3

SUPPORT SUPPORT
TAG MATERIAL

612 C.S.

612S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600, DS-PS-S602, DS-PS-X757
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. FIELD WELD ADDED H.L. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
05/16/95

2 T.G.
10/22/04
REF. STANDARDS ADDED DATE 03/28/95 DS-PS-S612 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS612.DGN
REINFORCING PAD PER
DESIGN STANDARD
DS-PS-S602 OR DS-PS-S600
IF SPECIFIED ON DRAWING

DO NOT CUT
"T" HOLE IN PIPE

STD. WT. DUMMY


PIPE
6mm END PLATE

B.O.P. ELEV.
SPEC. ON DWG

7mm dia. VENT HOLE

"L" 305

SPEC. ON
DWG
SEE NOTE 1 NOM. DUMMY
PIPE PIPE
DIA. DIA.

3" 3"

4" 3"

"T" = DUMMY PIPE 6" 4"


WALL THK.
8" 6"

10" 6"

12" 8"

14" 10"

16" 10"

18" 12"
SUPPORT SUPPORT 20" 14"
TAG MATERIAL
24" 14"
613 C.S. 30" 16"

613S 316 S.S. 36" 20"

NOTES:
1. "L" DIMENSION TO BE CALCULATED BY STRESS ENGINEER.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600, DS-PS-S602
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
1 T.G. REF. STANDARDS ADDED H.L. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
10/22/04

2 D.K.
11/18/05
NOTE 1 ADDED B.C. DATE 03/28/95 DS-PS-S613 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS613.DGN
PIPE CLAMP AS
SPECIFIED ON DRAWING

PLASTIC
PIPE

= =

REINFORCING PAD
SEE NOTE 1.

B = 1/2 PIPE DIA. THICKNESS :


2"-4" dia. : "T" = 3mm
OR 150mm MIN. 6"-24" dia. : "T" = 6mm
26"-36" dia. : "T" = 10mm

"T
"

60^ 60^

TYP. TYP.

NOTES:
1. WHERE REPAD OVERLAPS BUTT FUSION WELD BEAD, EXTERNAL BEAD IS TO BE
REMOVED PER MANUFACTURERS INSTRUCTIONS.

SUPPORT SUPPORT
TAG MATERIAL

615 C.S.

615S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-H410/H411
REV. BY REVISION APP. DES. DESIGNATION
DATE

CH. SUPPORT
SUP. DESIGN STANDARD NO. REV.

DATE DS-PS-S615 0
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSS615.DGN
REINFORCING PADS PER
DESIGN STANDARD DS-PS-600
FOR THIN WALL ONLY
LENGTH "B" TO SUIT
IF SPECIFIED ON DRAWING

50 MIN. DOUBLE RISER CLAMP


ANVIL INTL. FIG. 40 OR EQUAL
C/W SHEAR LUGS
SEE NOTE 1

LOCATION SPECIFIED
ON DRAWING
SEE NOTE 3
50 MIN.

REINFORCING PADS
PER DESIGN STANDARD
DS-PS-S614 FOR
THIN WALL ONLY

PIPE 6" dia. & LARGER IF SPECIFIED ON DRAWING


150 150
CLAMP TYPE
MAX. LOCATION SPECIFIED
ON DRAWING
SEE NOTE 3
65

6mm PLATE
RISER LUG

TYP.
TYP. OR
SEE NOTE 2
5 5

PIPE 4" dia. & SMALLER

LUG TYPE

CLAMP OR LUG
SUPPORT
TYPE ( SEE NOTES )
NOTES: TAG
/ MATERIAL
1. DESIGNER TO REFER TO DESIGN STANDARDS DS-PS-123 AND
DS-PS-125 FOR CLAMP AND SHEAR LUG CAPACITIES AND 616A FIG. 414A / C.S.
SHEAR LUG CAPACITIES AND DIMENSIONS.
616B FIG. 414B / C.S.
2. FIELD WELD APPLIES ONLY TO NON-RUBBER LINED PIPE.
616C FIG. 414C / C.S.
FOR RUBBER LINED PIPE, LUGS TO BE SHOP WELDED.
616D FIG. 414D / C.S.
3. FOR RUBBER LINED PIPE, INCLUDE 20 mm SHIM ALLOWANCE
OR AS SPECIFIED ON DRAWING. 616E LUG TYPE / C.S.

616AS FIG. 414A / 316 S.S.

616BS FIG. 414B / 316 S.S.

616CS FIG. 414C / 316 S.S.

616DS FIG. 414D / 316 S.S.

616ES LUG TYPE / S.S

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-S600, DS-PS-614, DS-PS-123, DS-PS-124
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
1 Y.T. SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

2 D.K.
11/21/05
ADDED WELD NOTES FOR
RUBBER LINED PIPE
B.C. DATE 03/28/95 DS-PS-S616 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSH416.DGN
STRUCTURAL STEEL MEMBER DETAILS

& CODE NUMBERS

MAX.
STEEL MAX.
STEEL FLANGE
CODE LAYOUT ROD
MEMBER BOLT
NUMBER DIA.
DIA.

1 L64 x 64 x 9.5 1/2

2 L102 x 102 x 9.5 3/4

3 (2) L102 x 102 x 9.5 5/8

4 C100 x 8 5/8

5 (2) C100 x 8 5/8

6 C150 x 12.2 5/8

7 (2) C150 x 12.2 3/4

8 W100 x 19.3 5/8

9 W150 x 22.5 3/4

10 W200 x 26.6 3/4

11 W250 x 32.7 3/4

12 W310 x 38.7 3/4

NOTES

1. SUPPORT STEEL MEMBERS SHALL BE SPECIFIED IN THE PIPE SUPPORT IDENTIFICATION


BLOCK USING THE SIZE DESIGNATING NUMBERS ABOVE.

2. THE STRUCTURAL MEMBERS SPECIFIED FROM THE ABOVE TABLE ARE OF THE MINIMUM
WEIGHT REQUIRED. IF A MEMBER IS NOT AVAILABLE AS SPECIFIED ABOVE, IT SHOULD
BE SUBSTITUTED WITH A MEMBER OF THE SAME SIZE BUT WITH A HEAVIER WEIGHT.

3. STRUCTURAL ANGLES WHEN REQUIRED FOR THE SUPPORT OF HANGER RODS SHALL BE
INSTALLED WITH THEIR HORIZONTAL LEG AT THE BOTTOM TO FACILITATE THE WELDING
OF A HANGER ROD BEAM ATTACHEMENT. USE MEMBERS 1 & 2 ONLY FOR LIGHT LOADS.

4. ALL WELDS TO STRUCTURAL STEEL ARE 5mm FILLET, EXCEPT 7mm FILLET FOR
MEMBERS 10, 11 AND 12. WELDS SHALL BE ALL AROUND WHERE POSSIBLE.

5. WHEN WELDING TO U/S OF A LOADED BEAM, THE WELDING BEAD SHOULD ALWAYS BE
APPLIED IN A DIRECTION PARALLEL TO THE BEAM’S LONGITUDINAL CENTERLINE.

6. WHEN A 316 S.S. MEMBER IS REQUIRED AND IS NOT AVAILABLE AS SPECIFIED ABOVE,
IT SHOULD BE FABRICATED FROM HOT-ROLLED PLATES TO DIMENSIONS SIMILAR TO
THOSE OF THE SPECIFIED STEEL MEMBER.

7. EXCEPT WHERE NOTED, THESE DETAILS ARE INTENDED FOR ATTACHMENT TO STEEL
OR CONCRETE STRUCTURES OR TANKS ONLY. SUITABILITY FOR OTHER APPLICATIONS
MUST BE CONFIRMED PRIOR TO USE.

8. ALL CARBON STEEL STRUCTURAL MEMBERS ARE TO BE PAINTED PER PROJECT STANDARDS.

9. DESIGNER IS RESPONSIBLE FOR SELECTING THE APPROPRIATE STEEL CODE NUMBER


TO SUIT PIPE LOADING.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

SUP. DESIGN STANDARD NO. REV.


H.LESKIE

DATE 03/28/95 DS-PS-X700 0


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX700.DGN
STEEL CODE No. CLIP ANGLE
(PER DS-PS-X700) TYPE

6 - 9 - 10 - 11 - 12 "A"

2 - 4 - 8 "B"

USE 5/8" ^ A325 BOLTS

CLIP ANGLE TYPE "A" CLIP ANGLES TYPE "B"


L 102 x 102 x 9.5 21 20 2-L 152 x 102 x 9.5

18

SLOT DETAIL

DIMENSION TO SUIT 63 +
-
TYP.
SLOT. SEE 38 +
-
DETAIL TYP.
=

NEW STEEL AS SPECIFIED


ON DWG. SEE DESIGN STANDARD

No. 6 & 9
FOR STEEL CODE

FOR STEEL CODE


=

100
DS-PS-X700

No. 10, 11 & 12


63

C HOLES FOR CLIP CLIP ANGLE


ANGLE TYPE "B" TYPE "A" OR "B"

DRILL 18mm dia. HOLES


IN EXISTING STEEL

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-X701 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX701.DGN
EXTRA STEEL MEMBER SPECIFIED
ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
WELDING FILLET SIZE, SEE
DESIGN STANDARD DS-PS-X700 "A"

AS SPEC. ON DWG.

T.O.S. ELEV.
SPEC. ON PLAN

"L" ( MAX. )

LOCATE ADDITIONAL STEEL MEMBER AS


HIGH AS POSSIBLE BETWEEN BEAMS

FOR BOLTED ATTACHMENT


COMPONENTS AND DETAIL,
SEE DESIGN STANDARD
DS-PS-X701

STEEL CODE MAXIMUM MAXIMUM


NUMBER SPAN "L" LOAD (kN)

8 1830 22.2

9 3050 31.1

10 4270 22.2

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR SPANS OR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.

3. WHEN USED FOR SUPPORTING MULTIPLE PIPES, DESIGNER MUST PROVIDE DIMENSION "A"
FOR ONLY ONE PIPE.

SUPPORT ATTACHEMENT
TAG TYPE / MATERIAL

702B BOLTED / C.S.

702W WELDED / C.S.

702BS BOLTED / 316 S.S.

702WS WELDED / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700, DS-PS-X701
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-X702 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX702.DGN
EXTRA STEEL MEMBER SPECIFIED
ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
WELDING FILLET SIZE, SEE
DESIGN STANDARD DS-PS-X700

"A"

AS SPEC.
ON DWG.

T.O.S. ELEV.
SPEC. ON PLAN

FOR BOLTED ATTACHMENT


COMPONENTS AND DETAIL,
SEE DESIGN STANDARD
DS-PS-X701 OR DS-PS-X753
FOR ATTACHING TO CONCRETE.

"L" ( MAX. )

STEEL CODE MAXIMUM MAXIMUM


NUMBER SPAN "L" LOAD (kN)

8 1830 22.2

9 3050 31.1

10 4270 22.2

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR SPANS OR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
3. WHEN USED FOR SUPPORTING MULTIPLE PIPES, DESIGNER MUST PROVIDE DIMENSION "A"
FOR ONLY ONE PIPE.

SUPPORT ATTACHEMENT
TAG TYPE / MATERIAL

703B BOLTED / C.S.

703W WELDED / C.S.

703BS BOLTED / 316 S.S.

703WS WELDED / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700, DS-PS-X701, DS-PS-X753
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-X703 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX703.DGN
25mm Min. CLEARANCE BETWEEN
STEEL AND PIPE MATERIAL
(INSULATION, U-BOLTS,
HANGERS, ETC)

FOR BOLTED CONNECTION


SEE DESIGN STANDARD
DS-PS-X701 TYPE "B"

"A"

AS SPEC.
ON DWG.

"B"
SEE NOTE 4

"C"
"L" ( MAX. )

"D"
WT75 x 11

FOR BOLTED CONNECTION EXTRA STEEL MEMBER SPECIFIED


SEE DESIGN STANDARD ON PIPE SUPPORT DRAWING
DS-PS-X701 FOR STEEL MEMBER CODE AND
WELDING FILLET SIZE, SEE
DESIGN STANDARD DS-PS-X700

STEEL CODE MAXIMUM MAXIMUM LOAD


NUMBER SPAN "L" PER LEVEL (kN)

4 1520 8.9

8 1520 22.2

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR SPANS OR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.

3. THIS SUPPORT IS FOR A MAXIMUM OF THREE LEVELS ONLY

4. DESIGNER SHALL PROVIDE DIMENSION "A" FOR ONE PIPE ONLY.

SUPPORT ATTACHEMENT
TAG TYPE / MATERIAL

704B BOLTED / C.S.

704W WELDED / C.S.

704BS BOLTED / 316 S.S.

704WS WELDED / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700, DS-PS-X701
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

2 D.K.
11/21/05
DIMENSIONS LABELLED B.C. DATE 03/28/95 DS-PS-X704 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX704.DGN
BEAM LOADING TO BE
APPROVED BY THE
STRUCTURAL ENGINEER.

FOR BOLTED CONNECTION


SEE DESIGN STANDARD
DS-PS-X701 TYPE "B"

"A"

AS SPEC.
ON DWG.

"B"
SEE NOTE 4

"C"
"L" ( MAX. )

"D"
WT75 x 11

( TYP.)

EXTRA STEEL MEMBER SPECIFIED 25mm Min. CLEARANCE BETWEEN


ON PIPE SUPPORT DRAWING STEEL AND PIPE MATERIAL
FOR STEEL MEMBER CODE AND (INSULATION, U-BOLTS,
WELDING FILLET SIZE, SEE HANGERS, ETC)
DESIGN STANDARD DS-PS-X700

STEEL CODE MAXIMUM MAXIMUM LOAD


NUMBER SPAN "L" PER LEVEL (kN)

4 1520 8.9

8 1520 22.2

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE GUIDES, ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR SPANS OR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
3. THIS SUPPORT IS FOR A MAXIMUM OF THREE LEVELS ONLY.

4. DESIGNER SHALL PROVIDE DIMENSION "A" FOR ONE PIPE ONLY.

SUPPORT ATTACHEMENT
TAG TYPE / MATERIAL

705B BOLTED / C.S.

705W WELDED / C.S.

705BS BOLTED / 316 S.S.

705WS WELDED / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700, DS-PS-X701
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

2 D.K.
11/21/05
DIMENSIONS LABELLED B.C. DATE 03/28/95 DS-PS-X705 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX705.DGN
T.O.S. ELEV.
SPEC. ON PLAN

"A"

AS SPEC. ON DWG.
FOR BOLTED ATTACHMENT,

SPACER BLOCK USE 5/8" dia. A325 BOLTS

IF REQUIRED C/W NUTS & LOCK WASHERS

"L"

EXTRA STEEL MEMBER SPECIFIED


ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
WELDING FILLET SIZE, SEE
DESIGN STANDARD DS-PS-X700

STEEL CODE MAXIMUM MAXIMUM


NUMBER SPAN "L" LOAD (kN)

8 1830 22.2

9 3050 31.1

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE GUIDES, ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR SPANS OR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.

3. WHEN USED FOR SUPPORTING MULTIPLE PIPES, DESIGNER MUST PROVIDE DIMENSION "A"
FOR ONLY ONE PIPE.

SUPPORT ATTACHEMENT
TAG TYPE / MATERIAL

706B BOLTED / C.S.

706W WELDED / C.S.

706BS BOLTED / 316 S.S.

707WS WELDED / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700,
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-X706 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX706.DGN
T.O.S. ELEV.
SPEC. ON PLAN

FOR BOLTED ATTACHMENT,


USE 5/8" dia. A325 BOLTS
SPACER BLOCK
C/W NUTS & LOCK WASHERS
IF REQUIRED

"A" 75mm MIN.

"B" "L"

EXTRA STEEL MEMBER SPECIFIED


ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
WELDING FILLET SIZE, SEE
DESIGN STANDARD DS-PS-X700

STEEL CODE MAXIMUM MINIMUM MAXIMUM


NUMBER SPAN "A" SPAN "L" LOAD (kN)

8 610 3 x "A" 22.2

9 610 3 x "A" 31.1

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE GUIDES, ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR SPANS OR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.

SUPPORT ATTACHEMENT
TAG TYPE / MATERIAL

707B BOLTED / C.S.

707W WELDED / C.S.

707BS BOLTED / 316 S.S.

707WS WELDED / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700,
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

2 D.K.
11/18/05
DIMENSIONS RE-LABELLED B.C. DATE 03/28/95 DS-PS-X707 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX707.DGN
"A" "L" 610 MAX.

1220 MAX. SEE SUPPORT DWG

T.O.S. ELEV.
SPEC. ON PLAN

6mm STOP PLATE

45^ WHERE
POSSIBLE EXTRA STEEL MEMBER SPECIFIED
ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
WELDING FILLET SIZE, SEE
DESIGN STANDARD DS-PS-X700
75

MIN.

WT 75 x 11

STEEL CODE MAXIMUM


NUMBER LOAD (kN)

8 22.2

9 31.1

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.

SUPPORT EXTRA STEEL


TAG MATERIAL

708 C.S.

708S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

2 D.K.
11/18/05
DIMENSIONS LABELLED B.C. DATE 03/28/95 DS-PS-X708 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX708.DGN
WT75 x 11

45^ WHERE EXTRA STEEL MEMBER SPECIFIED


POSSIBLE ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
WELDING FILLET SIZE, SEE
DESIGN STANDARD DS-PS-X700

B.O.S. ELEV.
SPEC. ON PLAN

1220 MAX. 75

"L"

STEEL CODE MAXIMUM


NUMBER LOAD (kN)

8 22.2

9 31.1

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE GUIDES, ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR SPANS OR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.

SUPPORT EXTRA STEEL


TAG MATERIAL

709 C.S.

709S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

2 D.K.
11/18/05
DIMENSIONS LABELLED B.C. DATE 03/28/95 DS-PS-X709 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX709.DGN
SUPPORT STEEL

WELDED ATTACHMENT
ANVIL INTL. FIG. 66
OR EQUAL

"L"
WELDLESS EYE NUT
ANVIL INTL. FIG. 290 "A"
OR EQUAL
AS SPEC.
ON DWG.

HANGER ROD C/W LOCK SEE NOTE 3

NUTS
100 MIN.

"B"

T.O.S. ELEV.
SPEC. ON PLAN

EXTRA STEEL MEMBER SPECIFIED


ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
WELDING FILLET SIZE, SEE
DESIGN STANDARD DS-PS-X700

STEEL CODE MAXIMUM MAXIMUM MAXIMUM


NUMBER SPAN "L" SPAN "B" LOAD (kN)

4 1520 1/3 x "L" 8.9

8 1520 1/3 x "L" 22.2

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
GUIDES, ANCHORS, AND DIRECTIONAL ANCHORS ARE NOT TO BE USED IN
CONJUNCTION WITH THIS DETAIL.

2. FOR SPANS OR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE
SELECTION SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.

3. WHEN USED FOR SUPPORTING MULTIPLE PIPES, DESIGNER MUST PROVIDE DIMENSION "A"
FOR ONLY ONE PIPE.

SUPPORT EXTRA STEEL


TAG MATERIAL

710 C.S.

710S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-110, DS-PS-112 DS-PS-X700
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
03/28/95
ISS’D FOR CONSTRUCTION H.L. CH. Y.T. EXTRA STEEL
T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.
1 Y.T. SUP. H.LESKIE
10/22/04 "GRINNELL" CHG’D TO "ANVIL INTL."

2 D.K.
11/18/05
DIMENSIONS RE-LABELLED B.C. DATE 03/28/95 DS-PS-X710 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX710.DGN
"D"

MIN.

PIPE SHOE IF APPLICABLE


38

TYP. 12mm THK PLATE

"D"

TOP PLATE PER DETAIL

"HEIGHT" AS SPEC. ON DWG.


7
1220 MAX.

STEEL SIZE PER TABLE

BASE PLATE PER DESIGN


STANDARD DS-PS-X756
7 IF SPECIFIED ON DRAWING

GROUT

CONCRETE PEDESTAL
WHERE APPLICABLE

PIPE DIA. STEEL BASE TOP PLATE


"D" SIZE PLATE DIM. "D"

3" - 6" W100 x 19.3 TYPE 1 150

8" - 12" W150 x 22.5 TYPE 1 200

14" - 18" W200 x 46.1 TYPE 2 255

20" - 24" W250 x 73 TYPE 2 305

NOTES:
1. THIS SUPPORT IS DESIGNED FOR VERTICAL LOADING ONLY. GUIDES, ANCHORS,
AND DIRECTIONAL ANCHORS ARE NOT TO BE USED IN CONJUNCTION WITH
THIS DETAIL WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER.

SUPPORT EXTRA STEEL


TAG MATERIAL

713 C.S.

713S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X756
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

2 D.K.
11/18/05
DIMENSIONS LABELLED B.C. DATE 03/28/95 DS-PS-X713 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX713.DGN
"W" SPEC. ON DWG.

125 MIN.

PIPE SHOE IF APPLICABLE


38

TYP. 12mm THK PLATE

125

TOP PLATE PER DETAIL

"HEIGHT" AS SPEC. ON DWG.


7
915 MAX.

STEEL SIZE PER TABLE

BASE PLATE PER DESIGN


STANDARD DS-PS-X756
7 IF SPECIFIED ON DRAWING

GROUT

CONCRETE PEDESTAL
WHERE APPLICABLE

DIAMETER OF STEEL BASE MAX. HORIZ.


SUPPORTED PIPE SIZE PLATE LOAD (kN)

3" - 6" HSS 127 x 127 x 6.4 TYPE 1 8.9

8" - 12" HSS 127 x 127 x 6.4 TYPE 1 8.9

NOTES:
1. THIS SUPPORT IS DESIGNED FOR MAXIMUM HORIZONTAL LOADS INDICATED ONLY.

2. MAXIMUM LATERAL PIPE MOVEMENT IS 75mm AT SUPPORT POINT.

3. FOR LOADS, HEIGHTS, AND PIPE SIZES GREATER THAN THOSE LISTED, DESIGN
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.

SUPPORT EXTRA STEEL


TAG MATERIAL

716 C.S.

716S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X756
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

2 D.K.
11/21/05
DIMENSIONS LABELLED B.C. DATE 03/28/95 DS-PS-X716 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX716.DGN
"A" "L" 610 MAX.

1220 MAX. SEE SUPPORT DWG

T.O.S. ELEV.
SPEC. ON PLAN

6mm STOP PLATE

45^ WHERE
POSSIBLE

75 IF APPLICABLE

MIN.

WT75 x 11

((4) 3/4 " DIA. x 9" LONG HILTI


HIT HY 150 ADHESIVE ANCHORS
12mm PLATE
IF ATTACHED TO CONCRETE,
SEE NOTES 3 & 4

50
OR (4) 3/4 " DIA. A325 BOLTS
IF ATTACHED TO STRUCTURAL
STEEL. HOLE SIZE TO SUIT

MAX
38
EXTRA STEEL MEMBER SPECIFIED
ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
STEEL CODE MAXIMUM
WELDING FILLET SIZE, SEE
NUMBER LOAD (kN)
DESIGN STANDARD DS-PS-X700

TO SUIT
8 22.2

9 31.1

FOR TANK
MTG. ONLY 5

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL
LOADING ONLY, WHERE ANCHORS, OR DIRECTIONAL ANCHORS ARE
USED IN CONJUNCTION WITH THIS DETAIL, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
2. FOR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE

50
SELECTION SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
3. FOR TANK MOUNTING, PLATE MATERIAL AND THICKNESS SHALL 38 38
MATCH TANK WALL; SHAPE TO SUIT.
4. TANK VENDOR MUST BE NOTIFIED OF ANTICIPATED LOADING ON TANK. 200

SUPPORT EXTRA STEEL


TAG MATERIAL

750 C.S.

750S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

3 T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.


SUP. H.LESKIE
10/22/04 HILTI ANCHOR TYPE CHG’D

4 D.K.
11/21/05
DIMENSIONS LABELLED B.C. DATE 03/28/95 DS-PS-X750 4
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX750.DGN
12mm PLATE
SEE NOTES 3 & 4

WT 75x11

45^ WHERE
POSSIBLE

B.O.S. ELEV.

50
SPEC. ON PLAN

1220 MAX. 75 ((4) 3/4 " DIA. x 9" LONG HILTI

MAX.
38
"L" HIT HY 150 ADHESIVE ANCHORS
IF ATTACHED TO CONCRETE,
OR (4) 3/4 " DIA. A325 BOLTS
IF ATTACHED TO STRUCTURAL
STEEL. HOLE SIZE TO SUIT

TO SUIT
FOR TANK
MTG. ONLY 5

STEEL CODE MAXIMUM

MAX.
NUMBER LOAD (kN) EXTRA STEEL MEMBER SPECIFIED

38
8 22.2 ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
9 31.1
WELDING FILLET SIZE, SEE
DESIGN STANDARD DS-PS-X700

50
NOTES:
38 38
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL
LOADING ONLY, WHERE ANCHORS, OR DIRECTIONAL ANCHORS ARE
200
USED IN CONJUNCTION WITH THIS DETAIL, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
2. FOR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE
SELECTION SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
3. FOR TANK MOUNTING, PLATE MATERIAL AND THICKNESS SHALL
MATCH TANK WALL; SHAPE TO SUIT.
4. TANK VENDOR MUST BE NOTIFIED OF ANTICIPATED LOADING ON TANK.

SUPPORT EXTRA STEEL


TAG MATERIAL

751 C.S.

751S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

2 T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.


SUP. H.LESKIE
10/22/04 HILTI ANCHOR TYPE CHG’D

3 D.K.
11/21/05
DIMENSIONS LABELLED B.C. DATE 03/28/95 DS-PS-X751 3
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX751.DGN
EXTRA STEEL MEMBER SPECIFIED
ON PIPE SUPPORT DRAWING
"L" "A" 455 MAX. FOR STEEL MEMBER CODE AND

SEE TABLE SEE SUPPORT WELDING FILLET SIZE, SEE


DESIGN STANDARD DS-PS-X700
DWG

200

38 38

50
T.O.S. ELEV.
SPEC. ON
PLAN

MIN.
255
6mm STOP
PLATE

FOR TANK

50
MTG. ONLY 5

12mm PLATE
SEE NOTES 3 & 4
((4) 3/4 " DIA. x 9" LONG HILTI
HIT HY 150 ADHESIVE ANCHORS
IF ATTACHED TO CONCRETE,
OR (4) 3/4 " DIA. A325 BOLTS
IF ATTACHED TO STRUCTURAL
STEEL. HOLE SIZE TO SUIT

STEEL CODE MAXIMUM MAXIMUM


NUMBER LOAD (kN) "A"

8 11.1 455

8 4.4 760

8 2.2 1060

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
3. FOR TANK MOUNTING, PLATE MATERIAL AND THICKNESS SHALL
MATCH TANK WALL; SHAPE TO SUIT.
4. TANK VENDOR MUST BE NOTIFIED OF ANTICIPATED LOADING ON TANK.

SUPPORT EXTRA STEEL


TAG MATERIAL

753 C.S.

753S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

3 T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.


SUP. H.LESKIE
10/22/04 HILTI ANCHOR TYPE CHG’D

4 D.K.
11/21/05
DIMENSIONS LABELLED B.C. DATE 03/28/95 DS-PS-X753 4
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX753.DGN
EXTRA STEEL MEMBER SPECIFIED
ON PIPE SUPPORT DRAWING
FOR STEEL MEMBER CODE AND
WELDING FILLET SIZE, SEE
"L"
DESIGN STANDARD DS-PS-X700
SEE TABLE
200

38 38

50
T.O.S. ELEV.
SPEC. ON PLAN

MIN.
255
FOR TANK
MTG. ONLY 5

50
(4) 3/4 " DIA. x 9" LONG HILTI
HIT HY 150 ADHESIVE ANCHORS
IF ATTACHED TO CONCRETE,
12mm PLATE OR (4) 3/4 " DIA. A325 BOLTS
75
SEE NOTES IF ATTACHED TO STRUCTURAL
3 & 4 STEEL. HOLE SIZE TO SUIT

STEEL CODE MAXIMUM MAXIMUM


NUMBER LOAD (kN) "L"

8 11.1 455

8 4.4 760

8 2.2 1060

NOTES:
1. MAXIMUM SPANS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, STEEL SIZE SELECTION SHALL BE APPROVED BY THE
STRUCTURAL ENGINEER.
2. FOR VERTICAL LOADS GREATER THAN THOSE LISTED, STEEL SIZE SELECTION
SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.

3. FOR TANK MOUNTING, PLATE MATERIAL AND THICKNESS SHALL


MATCH TANK WALL; SHAPE TO SUIT.
4. TANK VENDOR MUST BE NOTIFIED OF ANTICIPATED LOADING ON TANK.

SUPPORT EXTRA STEEL


TAG MATERIAL

754 C.S.

754S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X700
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

2 T.G. REF. STANDARDS ADDED DESIGN STANDARD NO. REV.


SUP. H.LESKIE
10/22/04 HILTI ANCHOR TYPE CHG’D

3 D.K.
11/21/05
DIMENSIONS RE-LABELLED B.C. DATE 03/28/95 DS-PS-X754 3
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX754.DGN
STEEL "S"

"L"
AS SPEC. ON DWG.
SPEC. ON DWG

T.O.S. ELEV. "A"

25
SPEC. ON DWG 5

SUPPORT PLATE
ON DRAWING 6mm STOP PLATE
SPECIFIED

7
STD. WT. PIPE
"H"

NOM. SIZE "C"

6mm dia. VENT HOLE

BASE PLATE PER DESIGN


7 STANDARD DS-PS-X756
IF SPECIFIED ON DRAWING

GROUT OR CONCRETE
PEDESTAL IF APPLICABLE

"C"
STEEL SUPPORT MAXIMUM MAXIMUM MAXIMUM BASE
AS SPEC.
"S" PLATE HEIGHT "H" LENGTH "L" LOAD (kN) PLATE
ON DWG

3" C100 x 11 125 x 125 x 10 915 455 9.8 TYPE 1

4" W100 x 19 150 x 150 x 10 1220 610 7.1 TYPE 1

6" W100 x 19 200 x 200 x 10 1830 760 9.8 TYPE 2

8" W150 x 22 255 x 255 x 10 2430 915 8.0 TYPE 2

10" W200 x 36 305 x 305 x 10 3050 1220 5.7 TYPE 2

NOTES:
1. MAXIMUM DIMENSIONS AND LOADS INDICATED REPRESENT VERTICAL LOADING ONLY,
WHERE GUIDES, ANCHORS, OR DIRECTIONAL ANCHORS ARE USED IN CONJUNCTION
WITH THIS DETAIL, DESIGN SHALL BE APPROVED BY THE STRUCTURAL ENGINEER.
2. FOR DIMENSIONS OR VERTICAL LOADS GREATER THAN THOSE LISTED, DESIGN SHALL BE
APPROVED BY THE STRUCTURAL ENGINEER.

3. WHEN USED FOR SUPPORTING MULTIPLE PIPES, DESIGNER MUST PROVIDE DIMENSION "A"
FOR ONLY ONE PIPE.

SUPPORT EXTRA STEEL


TAG MATERIAL

755 C.S.

755S 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS
DS-PS-X756
REV. BY REVISION APP. DES. DESIGNATION
J.M.D./T.G.
DATE

0 T.G.
EXTRA STEEL
ISS’D FOR CONSTRUCTION H.L. CH. Y.T.
03/28/95

1 T.G. REF. STANDARDS ADDED SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-X755 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX755.DGN
GROUT PLATE AFTER LEVELLING

GROUT

MAX.
50
BASE PLATE

ENTIRE PAD AREA


TO BE ROUGHENED
3/4 " DIA. x 11" LONG HILTI HIT HY 150
ADHESIVE ANCHORS WITH LEVELING NUTS
SLAB-MOUNTED PLATE

115

MIN.

LEVELLING

GROUT

MAX.
BASE PLATE NUT

38
SUIT

CONC. PAD
TO

BY OTHERS

3/4 " DIA. x 11" LONG HILTI HIT HY 150


ADHESIVE ANCHORS WITH LEVELING NUTS

PAD-MOUNTED PLATE

305 SQ. 405 SQ.

38 38
TYP. TYP.

(4) 25 dia. (6) 25 dia.

HOLES HOLES

SUPPORT BASE PLATE /


TAG MATERIAL

TYPE 1 TYPE 2 756A TYPE 1 / C.S.

20mm THK 20mm THK 756B TYPE 2 / C.S.

756AS TYPE 1 / 316 S.S.

756BS TYPE 2 / 316 S.S.

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G. ISS’D FOR CONSTRUCTION H.L. CH. Y.T. EXTRA STEEL- ANCHOR BASE PLATE
03/28/95

1 T.G. PLT. THICKNESS REV’D. J.Z. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
03/19/96

2 T.G.
10/22/04
HILTI ANCHOR TYPE CHG’D DATE 03/28/95 DS-PS-X756 2
*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX756.DGN
GROUT PAD AFTER LEVELLING

50 MAX
GROUT
12mm
WEAR PLATE

GRIND
SMOOTH

ENTIRE PAD AREA


TO BE ROUGHENED
DRILL AND GROUT IN
5/8" dia. THREADED RODS
SLAB-MOUNTED PLATE
LEVELLING
NUT

FULL THREADED
NOTE: RODS SAME MATERIAL
AFTER POSITIONING & LEVELLING OF AS BASE PLATE
WEAR PLATE, BOLTS SHALL BE CUT
TO 6mm BELOW T.O. PLATE & PLUG
WELDED BEFORE GROUTING PAD.
GRIND FLUSH WITH PLATE SURFACE

305 SQ. 405 SQ.

75 100

TYP. TYP.
=

(2) 20mm dia. HOLES


=

(4) 20mm dia. HOLES

TYPE 1 TYPE 2

500 SQ. SUPPORT BASE PLATE /


TAG MATERIAL
100

TYP. 757A TYPE 1 / C.S.

757B TYPE 2 / C.S.

757C TYPE 3 / C.S.

757AS TYPE 1 / 316 S.S.


(4) 20mm dia. HOLES
757BS TYPE 2 / 316 S.S.

757CS TYPE 3 / 316 S.S.

TYPE 3

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G. ISS’D FOR CONSTRUCTION H.L. CH. Y.T.


EXTRA STEEL- WEAR PLATE
03/28/95

1 T.G. DESIGNATION REV’D. SUP. DESIGN STANDARD NO. REV.


H.LESKIE
10/22/04

DATE 03/28/95 DS-PS-X757 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPSX757.DGN
1. GENERAL

THE SYMBOLS TO BE USED AT THE PIPE SHALL INDICATE ONE OF THE FOLLOWING
TYPE OF SUPPORT:

DESIGN
STANDARD No.s

PIPE ANCHOR "A" FOR ANCHOR 200 - 249

DIRECTIONAL ANCHOR "DA" FOR DIRECTIONAL ANCHOR 250 - 299

PIPE GUIDE "G" FOR GUIDE 300 - 399

PIPE SUPPORT "H" FOR HANGER 400 - 499


"S" FOR SUPPORT 600 - 699
"X" FOR EXTRA STEEL 700 - 799

2. SUPPORT IDENTIFICATION SYMBOLS

EACH PIPE SUPPORT SHALL BE IDENTIFIED ON THE PIPING ISOMETRIC BY ONE


OR MORE FRAMES CONTAINING THE SUPPORT DESIGNATION. THE FRAMES
SHALL BE CONNECTED TO A SUPPORT SYMBOL WITH A LEADER LINE,
WITH ITS ARROW POINTING TO THE SUPPORT LOCATION.

3. SUPPORT DESIGNATION

3.1 GENERAL

GENERALLY, ONE FRAME WILL BE USED TO IDENTIFY THE METHOD OF SUPPORT.


THE FRAME SHALL BE DIVIDED IN 2 SECTIONS. THE TOP SECTION CORRESPONDS
TO THE SUPPORT NUMBER ON THE ISOMETRIC. THE BOTTOM SECTION CORRESPONDS
TO THE SUPPORT DESIGN STANDARD NUMBER OR SPECIAL SUPPORT DETAIL NUMBER.

EXAMPLE IDENTIFICATION

PS# WHERE "#" DENOTES THE PIPE SUPPORT


PS#
NUMBER ON THE ISOMETRIC.
eg. PS1, PS2, ETC.

PS-S605 SHOE ASSEMBLY,


PS-S605
DESIGN STANDARD NUMBER
DS-PS-S605

DESIGN STANDARD
PIPE SUPPORT
REF. STANDARDS

REV. BY REVISION APP. DES. DESIGNATION


J.M.D./T.G.
DATE

0 T.G. ISS’D FOR CONSTRUCTION H.L. CH. Y.T. SUPPORT DESIGNATION SHT. 1 OF 4
03/28/95

1 J.H. EXAMPLE 3.1 REVISED Y.T. SUP. DESIGN STANDARD NO. REV.
H.LESKIE
12/01/97

DATE 03/28/95 DS-PS-100 1


*DATE*TIME* CADD FILE No. PSP108\CAD\250\PIPE SUPPORT STANDARDS\DSPS100.DGN

You might also like