Process Design of Condenser
Process Design of Condenser
Process Design of Condenser
The following is the detailed design of the total condenser for the Distillation
column. The condenser is operated at the same pressure as that of the column. The vapor
from the column is condensed and sent as reflux and product. Any changes in
iterative steps. The final trial is presented here. The design methods used here are from
Shell side
T = 301.8 K = 28.8 °C
Tube Side
Cooling water at 35 °C
1. Heat Balance
2. LMTD
Q = UA(LMTD)
A = 439.86/(500X51.29)
A = 17.19 m2
4. Tubes
Choose 1” OD, 16 BWG tubes of 6ft length laid in a 1.25” Square pitch
Tube OD = 25.4 mm
Tube ID = 22.098 mm
K = 0.156; n = 2.291
Number of tubes in the central row (Nr) = 2/3(Db/pt) = 2/3(458.5/ (1.25X25.4)) = 9.627
film coefficient and recalculating the film coefficient using the film temperature.
The shell side film transfer coefficient is calculated by using a modified Nusselt’s
equation:
hC = 0.95kL[ρL(ρL-ρV)g / (µΓh)]1/3Nr-1/6
= 0.95X 0.1935 [787.0 (787.0 -0.2428) 9.81/(4.4 x10-3 x 3.2456 X10-2 )]1/310-1/6
= 437.16 W/ (m2K)
= 0.309 m/s
= 1944.32 W/(m2 K)