Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Quantum 4.0: The Connected Yarn Quality Assurance System

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

u QUANTUM 4.

0
The connected yarn quality assurance system

Technical Data

April 2021
USTER  QUANTUM 4.0
®

The connected yarn quality assurance system

Basic installation
Uster Quantum 4 . 0 is the connected yarn clearing and monitoring system for winding.

Overall Functions – Yarn clearing system with Smart Clearing Technology for
Installation – Basic clearing
– Smart Duo Technology
– Contamination Clearing
– Special application
– Alarm settings and indication at measuring head
– Defect and alarm details listed at the central clearing unit
– Monitor and control of winding data
– Cuts and alarm overview
– YARN BODY ™, Dense area, Scatterplot
– Classification data
– Q-Data
– Trend display
– Reports to USB stick
– iMH LED function to stop and analyze defects
– Uster Quantum Expert for central data management

Included in – Central Clearing Unit 7 (CCU7 ) – one standalone or


the delivery integrated unit per winding machine to control settings
and data. Integrations available with Murata QPRO ,
Saurer ACX6 , Savio PulsarS
– Intelligent measuring heads (iMH ) for each winding position
– Interface to the winding positions and connecting cables
– Documentation, Tools, Yarn Boards and Yarn Grades

Subsystem of the USTER  QUANTUM 4.0


®

Standard USTER ® QUANTUM – Uster Quantum Expert application software


equipment EXPERT – Central winding data management
– Machine monitoring control
– Advanced analysis and intuitive reporting
– Central article management
– Configuration of shift calendar, user management and
data export
– Connection to overall quality management platform
Uster Quality Expert
Technical Data 2
USTER  QUANTUM 4.0
®

The connected yarn quality assurance system

Scope of application
Application range Yarn types For all spun yarns consisting of natural fibers, blended fibers,
synthetic fibers, and ply-yarns

Languages DE , EN , CN , TR , VN , FR , IT , ES , PT , RU , ID , JP , TH , KR

Count range Nec 1.8 to Nec 354 / Nm 3 to Nm 600 / 1.7  tex to 333  tex

Maximum speed 2 , 500  m/min

Count range of the USTER  QUANTUM 4.0


®

iMH-C15

iMH-C20

iMH-O30

Option F30

Option PP

Nec 1.8 Nec 6 Nec 12 Nec 30 Nec 60 Nec 80 Nec 100 Nec 354
Nm 3 Nm 10 Nm 20 Nm 50 Nm 100 Nm 135 Nm 170 Nm 600
333 tex 100 tex 50 tex 20 tex 10 tex 7,4 tex 5,9 tex 1,7 tex

Winding machines

Manufacturer Actual machines Retrofit

Muratec QPRO EX, FPRO EX QPRO, FPRO, PC 21C

Saurer Schlafhorst Autoconer ACX6 (PreciFX) Autoconer AC6 (PreciFX), Autoconer AC5 and
ACX5, Autoconer AC338

Savio PulsarS, Polar Polar, Orion, Espero

Qingdao Hongda VCRO Spero, Smaro

Qingdao QTM Faro, ISPERO ISPERO

Lakshmi LAW60

Technical Data 3
USTER  QUANTUM 4.0
®

The connected yarn quality assurance system

Feature overview

Capacitive Capacitive Optical


and/or
optical
<C> <C>, <C.opt> <O>

C15 C15 F30 O30


C20 C20 F30

Basic clearing Thick and thin places N, S, L, T • • •

Count channel C, CC • • •

Periodical defects PF • • •

Swarm clearing swNSL, • • •


swT

Splice clearing Jp, Jm, U • • •

Smart Duo Cross clearing X •


clearing
Density clearing D, CD •

Switch capacitive / <C>, •


optical mode <C.opt>

Conductive yarn • •

Q-Data Yarn unevenness CV • • •

Imperfections IP • • •

Hairiness H •

Class alarm • • •

Tailored classes • • •

Contamination Foreign matter clearing FD, FL •


clearing dark and light

Swarm clearing swFD, swFL •

Vegetable matter VEG •


clearing

Polypropylene clearing PP O

Special Core yarn clearing MC, CMC, O


applications OC, COC

Blend mix-up BM O

Shade variation SV, CSV O

USTER  
®
Data system for yarn • • •
QUANTUM clearing
EXPERT

USTER ®  Rings pinning RSO 3D O O O


RSO 3D optimization

• This feature is included in this version of the sensor


O Product Option Key ( POK ) is needed to have access to the feature mentioned in the header of this column

Technical Data 4
USTER  QUANTUM 4.0
®

The connected yarn quality assurance system

Application Software for USTER  QUANTUM 4.0


®

Clearing settings Article settings – Article definition


– Clearing mode selection for different application
– Switch capacitive and optical basic clearing

Smart Clearing – Central smart limit button for a fast setup


Technology – Individual smart limits for data-based setting configuration
with cut forecast in the most intuitive and user-friendly way
(NSL , T, CC , CD , FD , FL , PP , MC , CMC , OC , COC , BM , CSV )
– Manual setting definition possible
– YARN BODY ™, Dense area and/ or Scatter plot display
– Clearing limit comparison

Alarms and – Yarn fault alarms set per number of faults and
Q-parameter reference length
settings – CV, H and IP with Smart limits and Data display
– Class alarms and tailored classes with separate settings

Special and – Linen, Twin splice, Wet splice


group settings – Special monitoring and alarm settings

Data display Machine summary – Trend display up to 9 shifts back


– Data per position
– Length, Yarn faults, Q-Data, Alarms, Q-Blockings,
Q-Cuts, Q-Registrations, Miscellaneous
– Favorites definition

Yarn faults, – Full display of active and inactive functions


Alarms and – Absolute and relative value display
Special Counters – Machine, group, spindle
– Current, shift (current and last 9 shifts), lot, day

Q-Data – Classification: NSLT , J, FD , FL , VEG , PP


– YARN BODY ™, Dense area and/or Scatterplot:
NSL , T, C, CC , D, CD , J, FD , FL , VEG , PP , SV, CSV
– CV, Hairiness, Imperfections, Class alarms
– Machine, group, spindle depending on display
– Current, shift, day depending on display

Logbook – General logbook and service logbook


– Information, warning, alarm
– Technical, textile

RSO 3 D Data – Quality map of ring spinning machine


– Section and spindle display per doff
– Favorites definition

Technical Data 5
USTER  QUANTUM 4.0
®

The connected yarn quality assurance system

Reports Standard reports – Pre-defined and customizable reports


printed to USB stick – Current, shift, lot, day
– Machine, group
– Yarn faults, Alarms, Classification, Q-Data
– Position exceptions (configurable)

Special reports – Article report


printed to USB stick – Service reports
– Event report
– Logbooks

Event report – Configurable list of events


– Date, time, position and event details

Service System info – iMH overview


– Version and connection state

Special functions – iMH LED display to inspect yarn defects


– Service functions

Start-up System settings – Language selection


– Unit systems:
– Yarn count: Nm, Ne, New, tex
– Classification: cuts/ total; remaining/ total
– Rel. value: /10  km, /100  km, /1,000  km
– Shift schedule if not commonly defined via
Uster Quantum Expert
– Alarm reset rights

Machine settings – Machine and group settings


– iMH display

Options – Options overview and activation


– Shareware options valid for 30 days

Operating Article control – Article list with up to 30 articles


functions – Stop and start of production groups with assigned articles

Alarm display – List of alarms – technical and textile


– Acknowledge alarms

Access rights – User login change via passwords


– Master key login

Online help – Explanation for all menus and submenus

Technical Data 6
USTER  QUANTUM 4.0
®

The connected yarn quality assurance system

USTER  QUANTUM 4.0 with connection to other systems


®

Total Contamination Based on the – USTER ® JOSSI VISION SHIELD


Control combination of – USTER ® VISION SHIELD EXPERT
(TCC ) – USTER ® QUANTUM 4.0
– USTER ® QUANTUM EXPERT
– USTER ® QUALITY EXPERT

Ring Spinning Based on the – USTER ® SENTINEL


Optimization combination of – USTER ® QUANTUM 4.0
(RSO ) – USTER ® QUANTUM EXPERT
– USTER ® QUALITY EXPERT

Ring Spinning Based on the – USTER ® SENTINEL


Optimization 3 D combination of – USTER ® QUANTUM 4.0
(RSO 3 D) – USTER ® QUANTUM EXPERT
– Muratec QPRO EX /FPRO EX with Spin Inspector

Uster Quality Expert Further value Alarm center, Mill analysis, Yarn prognosis
modules

RSO and RSO 3 D available for linked winders only

Installation conditions
General ambient Operating – Temperature: +5 to +50  °C (*)
conditions conditions – Humidity: < 80 % R.H. (non condensing)

Transport/Storage – Temperature: -20 to +85  °C


conditions – Humidity: 10  –  95 % R.H. (non condensing)

Application Typical experienced ambient conditions in winding are between


conditions 20  °C to 38  °C and 50 % to 69 % R.H. This may vary depending
on the produced raw materials. Spinning conditions are usually
controlled by a suitable air-conditioning.

(*) Temperature for CCU7 openframe integrated: + 5 to + 60  °C

Technical Data 7
05.21/© Copyright 2021 by Uster Technologies AG
Uster Technologies has made all possible efforts to ensure that all information is accurate at
the time of publication. Hereby it is declared that alterations to the product may be possible
at any time. In these cases the information contained in this technical datasheet is subject to
change without notice.
April 2021

USTER Switzerland

Knoxville, USA Osaka, Japan


Adana, Turkey Suzhou, China
Greenville, USA Shanghai, China
Caesarea, Israel

Coimbatore, India

Uster Technologies AG
Sonnenbergstrasse 10
8610 Uster
Switzerland
T. + 41 43 366 36 36
F. + 41 43 366 36 37
sales@uster.com
www.uster.com