Liebert NXR Series: 30kva To 200kva

Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

AC Power TM

for Business-Critical Continuity

Liebert NXr Series


30kVA to 200kVA
Anticipating Technology Changes
Through Adaptive Architecture
Today, you need a power infrastructure that can work across your
enterprise and respond to constant change. An infrastructure
that allows you to deploy blade servers and other high-density
equipment safely and cost-effectively. An infrastructure that can
meet the strict power quality requirements of VoIP switches.
An infrastructure that allows you to add capacity without compromising
availability or serviceability.

Scalability alone can’t get you there. You need an infrastructure that takes it
one step further. An infrastructure that can adapt to your needs.

How the Liebert NXr enables


Adaptive Architecture
Lowest Cost of Ownership
Liebert NXr is sized to minimize capital
equipment expenses and designed for
optimum efficiency Its low footprint saves
costly floorspace while effectively managing
data center facilities with high densities. It
provides 100% usable real power with high
generator compatibility because of low input
THDi, high input PF, low input cable and
switch gear rating.
The Liebert NXr

Extreme Performance Enhanced Operational Flexibility


 Up to 96% Efficiency In response to the demands of new
 Greater than 99% Input Power Factor
technologies, the Liebert NXr achieves higher
 Less than 3% input THDi
tiers of availability or support even with
Space Savings increased densities with minimal disruption
 200kVA UPS in less than 0.5m2 to operations. It has configurable battery
and standard top cable entry. Liebert NXr
Truly Adaptive and Flexible
 Top and bottom cable entry allows easy configuration of different system
 Less than 300 kg for a 160kVA UPS architecture like dual bus and parallel ability.
 Flexible battery configuration
12Vx 30/32/34/36/40 cell design

Higher System Availability


Liebert NXr provides a mission-critical
technology that minimizes single points of
failure in your network. A UPS that promises
the highest possible availability of your IT
systems, the Liebert NXr highlights reliability
with low mean time to repair (MTTR).
Unparalleled Efficiency
Low Footprint
Truly Adaptive and Flexible

Liebert NXr Why choose a Double-Conversion UPS?

Efficient and Adaptive Power For Your Only a double-conversion topology provides
100% protection with complete input to
Critical Applications output isolation and totally regenerated
The Liebert NXr from Emerson Network Power presents an efficient, space saving and power. A double-conversion UPS delivers
flexible solution for your network. With an above industry standard efficiency rate 100% power conditioning, zero transfer
time to battery, great stability of output
of up to 96% in a compact, low footprint UPS, Liebert NXr keeps your network
voltage and frequency and better transient
protected while saving on cost and data center space. suppression than line-interactive units.
With best in class true online double conversion technology, redundancy options
and flexible battery configurations, trust the Liebert NXr to provide the same level of Double-conversion systems also offer a
reliability you have come to expect from the Liebert NX UPS series. wider input voltage window that allows the
UPS to absorb deeper sags without having to
Features and Benefits transfer to battery.

 High efficiency rating of up to 96% on true online double conversion mode DSP Control
Full digital control technology provides
 High Power density with 200kVA load in <0.5m2 footprint
a highly accurate and drift-proof control
 Advanced digital signal processor (DSP) and digital control technology to ensure higher compared to traditional analog electronics.
system reliability These features enable the UPS to provide
accurate and reliable power protection
 Parallel technology allowing four (4) parallel units, without the need for centralized bypass under a wide range of conditions.
cabinet and additional external modules
 Digital current sharing technology for externely small circulating current and high parallel
reliability
 Wide input voltage and frequency range against harsh utility environment
 Power output overload and short circuit capacity enhancing system stability and system
safety under extreme conditions
 Intelligent battery management for automatic battery maintenance and prolonged
battery life
 6-Inch LCD display available in 12 different languages
 Layered Independent sealed duct and redundant fan design, circult board painting
Extended Load Ranges
protection and dust filter, offering outstanding protection from harsh environment
Modern Data Centers, Blade Servers, and IT
 Advanced monitoring and communication capabilities for improved visibility and control applications in general, need more active
power. Moreover; In some instances, new
 Lower mean time to repair (MMTR) with front access for maintenance
Data Centers have capacitive or leading
 Flexible UPS system configuration that works in different modes of operation features while traditional systems had
inductive power factors, also known as
Efficiency Savings lagging.

Commercial Tariff : Cost Based on Rs. 7 per kWH* Leading Power Factor
Annual This exists when capacitive circuits prevail
Traditional UPS Liebert NXr / Total Annual
Rating ( ή =@92%) APM ( ή =@96%)
Energy Cost Annual Air
Saving
Saving @ 10 over inductive circuits. In this case, current
Saving Con. Saving Years is said to be “leading”, because its curve
(kVA) Energy Charges Energy Charges (in INR)
(in INR) (in INR) (D) (In INR)
(in INR) (A) (in INR) (B) (C=A-B)
E =(C+D) on a 2D chart is phase-shifted ahead of the
30 1,999,565 1,916,250 83,315 35,706 119,022 1,190,220 voltage curve. A UPS must be able to work
60 3,999,130 3,832,500 166,630 71,413 238,043 2,380,430 according to real load requirements. While in
90 5,998,696 5,748,750 249,946 107,120 357,065 3,570,650 the past, 0.7-0.8 Power Factor was common
120 7,998,261 7,665,000 333,261 142,826 476,087 4,760,870 for IT applications, today’s computers PF is
150 9,997,826 9,581,250 416,576 178,533 595,109 5,951,090 getting closer to 1.

Industrial Tariff : Cost Based on Rs. 5 per kWH*


Traditional UPS Liebert NXr / Annual
Total Annual
Energy Cost Annual Air Saving @ 10
Rating ( ή = @92% ) APM ( ή =@96%) Saving
Saving Con. Saving Years
(kVA) Energy Charges Energy Charges (in INR) Other Saving:
(in INR) (in INR) (D) (in INR)
(in INR) (A) (in INR) (B) E =(C+D) • Foot Print
(C=A-B)
30 1,428,261 1,368,750 59,511 25,505 85,016 850,160 • Air Con
60 2,856,522 1,737,500 119,022 51,009 170,031 1,700,310 • Scalability (Save affront Cost, For APM Only)
90 4,284,793 4,106,250 178,533 76,514 255,047 2,550,470
• Space and Cost on Distribution (For APM Only)
120 5,713,043 5,475,000 238,043 102,018 340,062 3,400,620
150 7,141,304 6,843,750 297,554 127,523 425,078 4,250,780

*The prices assumed are average prices of electricity in India.


Impact of Footprint on TCO / OPEX
200 kVA UPS Model NXr Legacy Comments

Footprint (sq.ft.) 5.12 7.75 Footprint of UPS Module


Front Clearance (sq.ft.) 6.45 9.68 Front Clearance 1 meter clearance for maintenance
is assumed
Back Clearance (sq.ft.) 3.22 4.84 Back clearance 500 mm is assumed for maintenance
Total Area required per UPS Module (sq.ft.) 14.79 22.27
Total Annual Rental Charges (INR) 8874 13362 Commercial Rental charge per Sq.Ft : based on
Rs. 50/- per Month
Total Rental Charges @ 10 Years (In INR) 88740 133620 If Width of UPS Module increases
by 1 ft (or 304.8mm), the effective increase in
footprint is require
Total Saving with NXr UPS (in INR) 44880 Saving in OPEX due to reduced footprint

The best investment you can make in a UPS system:


Efficiency, Reliability and Value in a compact package.
How can I get the most out of my
• Wider input voltage and frequency • The unit’s compact footprint
Investment?
tolerances contribute to high requires less floor space, leaving
• Liebert NXr, with its unity power
power availability. you with more room for other
factor (kVA=kW), offers more
• Digital controls provide the fastest equipment.
real power to support customer’s
mission critical loads. possible power management • Liebert NXr has built in Parallel
to enhance reliability, accuracy and Load Bus Synchronization
• With up to 96% online double
and efficiency while reducing (LBS) boards. No extra hardware is
conversion efficiency, Liebert NXr
component count. needed, it may be easily connected
saves you operating cost
• Dual bus compatibility and system just with control cables.
compared to most traditional
UPS in the market. redundancy further enhance the
availability of a power. How can I satisfy the requirements
of the latest servers?
How can I get optimum protection • High overload protection handles • Liebert NXr is capable of driving
for my network with Liebert NXr? 110% overload for 60 minutes, wide ranges of loads, from 0.5
• The double conversion technology 125% for 10 minutes, and 150% for lagging to 0.9 leading. This makes
of Liebert NXr allows it to have an 1 minute. the UPS follow the latest IT industry
above average industry standard
trends, with more active power
of up to 96% efficiency, giving How can I save on my electricity
available for all kinds of loads.
your network and data center bill and investment costs?
equipment full protection at the • The improved input power factor How can I also protect also my
most efficient rate. of the Liebert NXr can actually upstream-connected devices?
reduce your electricity usage.
How can I save floorspace with • The Liebert NXr provides the
• It delivers the highest possible cleanest level of upstream power
Liebert NXr? input power factor - greater than
• Liebert NXr is a compact UPS with with the lowest level of input
0.99 at rated linear and non-linear current THDi in the industry.
low footprint. loads - for maximum efficiency
• A 200kVA Liebert NXr UPS can be • This ensures that clean power
• The unique ability of the Liebert flows upstream, avoiding damage
installed in less than 0.5m2 space. NXr to adjust power walk-in from 5 to other loads connected to the
seconds to 30 seconds, along with upstream power distribution bus.
How can i get the highest levels
reduced input current distortion
Protection and Availability?
and power factor correction, also
• Liebert NXr gives you built-in enables you to save money by
reliability with its stratified cooling reducing back-up generator sizing
technology allowing cooling of requirement.
critical components and
redundant cooling fan option.
How can I extend the system • Large and user-friendly LCD
when I need more power? display provides operating
• Liebert NXr features easy and information in twelve different
simple scalability and redundancy. languages.
Configurations: A Full Range Of Features
In fact, up to four Liebert NXr
How can I satisfy my particular To Meet All Your Power Availability Needs
modules may be paralleled in a
redundant configuration for added installation needs? Single Or Dual Input Operation
reliability and serviceability. • Flexibility is achieved through
Your Liebert NX power system can be utilized
many choices including type of
with either single or dual power inputs.
How can I ensure the UPS will work battery, number of single and The dual power feature allows you to take
under the most severe conditions? multi-unit configurations, and advantage of a secondary power source.
• The wide input voltage window of an array of internal and An optional wrap-around maintenance bypass
305V-477V and a frequency external power and is also offered for the single input configuration.
tolerance of 40Hz to 70Hz provide communication options.
high quality power, even when • Auto restart capability provides
input parameters are below added availability.
standard. This helps minimize
• Ultra-quiet performance with
transfer to battery, reducing the
noise levels below 55dBA allows
charging and discharging cycles.
greater latitude in where to place
• Back-feed protection sensing the unit.
ensures system integrity.
• Adjustable power walk-in,
• Short-circuit-proof, DSP controlled numerous user specified settings,
inverter provides highest output a choice of power monitoring
power quality. communications alternatives and
user friendly control are all
How can I easily maintain my UPS? handled through the menu-
• Liebert NXr includes a built-in driven LCD control panel
maintenance bypass, with IP 20 with detailed data reporting.
UPS enclosure protection - even
with the front doors open. • Emerson Network Power is
recognized to be a great
• Redundant configuration allows solution provider. Please contact
you to utilize one module while the your local Emerson Network
other is being serviced. Power office or Liebert
• Dual bus compatibility enables representative to receive
to transfer the load to an special solution consultancy.
alternate power source for
maintenance activities. How can I protect and extend
the life of my batteries?
How can I monitor and • Liebert NXr minimizes transfers to
communicate with my UPS? batteries with its wide input
• To meet a variety of needs, the voltage tolerance down to 305V.
Liebert NXr offers • Temperature-compensated
communications through web or battery charging extends battery
management systems through life.
MODbus and SNMP
communication protocol.

How can I check the status of


my UPS?
• The Liebert NXr features easy
access for service. Thanks to
front accessibility of critical
components, self-diagnostics
and various monitoring options.
Advanced Monitoring and Communications
Capabilities Keep You in Control
Power Communication Options
When choosing the best system to protect your mission critical applications, an important
consideration would be the software and communication options. As part of our commitment to provide the
best solution for you, we offer a wide range of sophisticated software and communication options for Liebert NXr.

The most extensive list of optional communication solutions for Liebert


NXr UPS Systems
Control through Building Management Systems via Modbus and Jbus protocols
 Web-enabled Monitoring and Management through SNMP protocols
 Network Management Systems
 Software Solutions
 Site Monitor Software
 Facility wide monitoring
 Shutdown software for your computer equipment
 Simultaneous monitoring via different protocols

Emerson Network Power Service


Emerson Network Power Service the largest technical support and
offers a wide variety of services and customer response organization in
maintenance programs designed the industry with factory trained
to keep your mission critical customer engineers and service
equipment operating continuously professionals in more than 100
and smoothly. Our aim is to design service centers ready to assist in
and offer an overall service package maintaining your uptime, 24 hours
to meet customer’s needs from a a day, every day of the year.
technical and commercial point of
view. Emerson Network Power Service
can provide service capability
More and more organizations for your entire business critical
around the world trust Emerson infrastructure: from AC and DC
Network Power Service to minimize power systems, to battery systems,
critical systems emergencies and commutation systems and
interruptions. We are backed by environmental and site monitoring
services.
Technical Specifications

Model NXr
Power (kVA) 30 kVA 60 kVA 90 kVA 120 kVA 150 kVA 100 kVA* 160 kVA* 200 kVA*
Power (KW) 30 KW 60 KW 90 KW 120 KW 150 KW 90 KW* 144 KW* 180 KW*
System efficiency
AC - AC online double conversion
75 - 100% Load Upto 96%
45 - 75% Load Upto 96%
25 - 45% Load Upto 95%
Input Parameters
Rated input voltage 380/400/415 VAC, three-phase four-wire
Rated operating frequency 50/60Hz
Input voltage range 305V - 477V at full load, -25% to -40% with linear load de-rating
Input frequency range 40Hz - 70Hz
Input power factor >0.99
Input THDi <3%
Input walk-in function Available, 5 - 30s (settable)
DC Parameter
Battery Type SMF / Wet Acid / Ni-Cd
Battery Compensation Yes
Charger output voltage regulation accuracy 1%
DC ripple low voltage ≤1%
Output Parameter
Inverter output voltage 380/400/415 VAC, three-phase four-wire
Inverter output frequency 50/60Hz
Output frequency stability 50Hz/60Hz±0.02%
Load power factor handling compatibility (without capacity derating) 0.9 leading - 0.9 lagging
Voltage stability
Steady state <±1%, typical
Transient state +/-5%, typical
Transient state response time <20ms
Inverter overload capacity 1 hour for 110%, 10 mins for 125%, 1 min for 150%, 200ms for >150%
Phase Shift
With 100% balanced load <1°
With 100% unbalanced load <1.5°
THDv
100% linear load <1%
100% non-linear load <1.5%
Bypass Parameter
Bypass input voltage 380/400/415 VAC, three-phase four-wire
Bypass voltage range settable through software Default: -20% to +15%, other values, such as -40%, -30%, -10% to +10%, +15%
Bypass overload capacity 135% long term, 170% for 1 hour, 1000% for 100ms
Environmental Conditions
Operating temperature range 0 - 40 °C*
Storage temperature -25 to 70 °C
Maximum Operating altitude ≤1000m, when operating at 1000>2000M, derated by 1% for every 100m increase of altitude
Relative Humidity ≤95%
Noise (1m) 55 - 62dB, adjusted according to load rate
IP Class IP20
Safety: IEC60950-1; IEC62040-1-1/AS62040-1-1,
Standards EMC: IEC62040-2/AS62040-2/EN50091-2 Class A,
Design and test: IEC62040-3/AS62040-3
Physical Parameters
Dimension, Width (mm) 600
Height (mm) 1400 1400 1400 1400 1400 1400 1400 1600
Depth (mm) 794
Weight (kg) 155 190 225 255 295 225 295 350