Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Liebert: GXT MT+ CX™ 1/2/3kVA UPS Compact, & Reliable Power For Mission-Critical Applications

Download as pdf or txt
Download as pdf or txt
You are on page 1of 6

Liebert®

GXT MT+ CX™


1/2/3kVA UPS

Compact, & Reliable Power


For Mission-Critical Applications
WE ARE VERTIV

Vertiv, formerly Emerson Network Power, designs, builds ,and services mission critical
technologies that enable vital applications for data centers, communication networks,
and commercial & industrial environments

We support today's growing mobile and cloud computing markets with our portfolio of
power, thermal and infrastructure management products, software and solutions, all
complemented by our extensive global service network.

We help strengthen the world's most vital applications by bringing together global
reach and local knowledge, and our decades-long heritage, including brands like
Chloride, Liebert, NetSure, and Trellis.

Vertiv vice & Consultatio


S er n
Your Vision, our Passion Software

nfrastru
With a unique combination if ie d I ct
Un ur
of industry expertise,
e
technology, and resources, Thermal Power
Management Management
our mission is to support
and power mission-critical IT
Management
technologies that drive
possibility.

Our global industrial Our global intelligently Our global power and Our industry-leading
power solutions meet the engineered DC power thermal management software gives customers
most demanding systems deliver high solutions are some of the an integrated view of
technical specifications availability, energy world’s most e icient and operations across IT and
and provide safe, reliable e iciency and scalability reliable power and facilities resources,
power- no matter the for converged networks cooling technologies enabling better decisions
challenge that save time and money

2
In this ever-changing dynamic world, the days of basic Liebert® G XT M T+ CXTM
power protection are passé. In today’s Internet-centric
era, business continuity is vital and companies cannot
afford downtime for their critical systems or waste time
recovering the systems after a disruption. Therefore,
there is a need for a power-integrated UPS, which
offers flexible protection for various applications areas
such as data networks, compact data center rooms,
voice networks, cellular sites, process automation
systems, and micro-control rooms among other edge
applications.

Our solution
Liebert® GXT MT+ CXTM is a sleek, high frequency,
double-conversion UPS with wide input voltage/
frequency and better output voltage regulation, which Application areas
makes it an ideal choice for harsh environments, • Data Network: Mid - range Servers (Windows
especially those facing concerns related to unstable and Linux), Wi-Fi Applications & Data networks
mains output and high load impact. This advanced
• Small Data Center Rooms
UPS provides higher availability while offering
intelligent monitoring and network management
• Voice Networks: Cellular Sites, Voice Over IP
functions. (VOIP), Very small Aperture Terminals
(VSAT) PBX And IT-enabled PBX Automation
The ultimate level of engineering and dynamics that industries
have gone beyond the development of this next-
• Process Automation Equipment: Programmable
generation UPS make it a high performance system
Logic Controllers (PLS) and Cash Machines
with proven reliability, giving you ultimate peace of (ATM)
mind.
The Liebert® GXT MT+ CXTM UPS facilitates Intelligent Management Functions
reliable & uninterrupted power even in stringent
conditions with integrated input power factor • Remote Monitoring is available via the USB/RS232
correction, low THDi, and advanced frequency ports; alternatively, dry contacts and SNMP are
regulation in a compact footprint. optional methods; supports TCP/IP with event logs
and analysis function.

Key Features • Self-diagnosis and protection enable the auto


shutdown of the client terminal or server under
• IGBT-based Rectifier abnormal mains supply or when the battery is over
discharged; Extended Run Time is facilitated through
• True on-line double-conversion efficiency (up to a simple process of building up additional battery
90%) with DSP Control Technology for high resources.
Performance & reliability
• SNMP Management Card (optional) allows remote
• Active Input Power Factor Correction 0.99; 0.9 monitoring via RJ45 connection ports; allows the
Output Power Factor management of several UPS systems via the Internet;
Real-time dynamic graphs of the UPS data, warning
• Ultra-wide Input Voltage window: 280VAC; notifications via audible alarms, broadcast, mobile
works well in harsh conditions and suitable for message, e-mail & SNMP traps are some of the key
very poor quality power grid functionalities.

• Generator-compatible with a wide Input


Frequency range
(40Hz-70Hz) Runtime Chart

• Built-in 50/60 Hz automatic frequency


converter and a configurable output voltage
(200, 208, 220, 230, up to 240 Vac)

This transformer-free UPS, with a fault-tolerant design, ensures mission-critical continuity, whileproviding clean
and consistent power protection in unpredictable environments.
MODEL GXT MT + CX 1 kVA GXT MT + CX 2 kVA GXT MT + CX 3 kVA

PHASE 1 phase in / 1 phase out


Standard Models 1000 VA / 900 W 2000 VA / 1800 W 3000 VA / 2700 W
CAPACITY
Long Backup Models 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W

INPUT
Nominal Voltage 230 Vac
110 VAC ± 3% at 50% Load
Low Line Loss
176 VAC ± 3% at 100% Load
120 VAC ± 3% at 50% Load
Voltage Range Low Line Comeback
186 VAC ± 3% at 100% Load
High Line Loss 280 VAC ± 3%
High Line Comeback 270 VAC ± 3%
Frequency Range 40 Hz ~ 70 Hz
Power Factor ≥ 0.99 @ 100% load
OUTPUT
Nominal Voltage 208/220/230/240VAC
AC Voltage Regulation ± 1%
Frequency Range (Synchronized Range) 46Hz ~ 54 Hz or 56Hz ~ 64 Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≤ 3 % THD (Linear Load), ≤ 7 % THD (Non-linear Load)
Transfer Time Bypass to Inverter (Line mode) Zero
Inverter to Bypass (Line mode) 4 ms (Typical)
Waveform (Batt. Mode) Pure Sinewave
EFFICIENCY on AC to AC mode@ 100% load. 88% 88% 90%
Inbuilt Isolation Transformer No
BATTERY
Battery Type 12V/ 9 AH 12V/ 9 AH 12V/ 9 AH
Standard Run Numbers 2 4 6
Model Typical Recharge Time 4 hours recover to 90% capacity
Charging Current (max.) 1.0 A
Charging Voltage 27.4VDC ± 1% 54.7 VDC ±1% 82.1 VDC ±1%
Battery Type Depending on the capacity of external batteries
Long Run Numbers 3 6 6
Model
Charging Current 1.0A/2.0A/4.00.0A, 6.0A default
Float Charging Voltage 41.0 VDC ± 1% 82.1 VDC ±1% "82.1 VDC *1%
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Countinously sounding
PHYSICAL
"Standard Run Dimension, D x W x H (mm) 282 x 145 x 220 397 x145 x220 421 x 190 x 318
Model Net Weight (kgs) 9.8 17 27.6
Long Run Dimension, O x W x H (mm) 282 x 145 x 220 397 x145 x220
Model* Net Weight (kgs) 4.1 6.8 7.4
ENVIRONMENT
Operation Humidity and Temperature 20-90 % RH @ 0- 45°C (non-condensing)
Noise Level Less than 50dBA @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser

* Derate to 80% of capacity in Frequency converter mode,the output voltage is adjusted to 100/200/208VAC and the ambient temperature during 45°C to 50°C
* * Product specifications are subject to change without further notice