Transducer Up To 4500 MM Touchless Absolute Series TLM With Start/ Stop-, Ssi-, Dymos-, Analog-Interface
Transducer Up To 4500 MM Touchless Absolute Series TLM With Start/ Stop-, Ssi-, Dymos-, Analog-Interface
Transducer Up To 4500 MM Touchless Absolute Series TLM With Start/ Stop-, Ssi-, Dymos-, Analog-Interface
up to 4500 mm
Touchless Absolute
Series TLM with Start/
Stop-, SSI-, DyMoS-,
Analog- Interface
Special features Transducers employ the The high mechanical ruggedness Stop pulse interface and analog
• absolute transducer, no slide NOVOSTRICTIVE® touchless of the transducer combined with voltage or current interfaces, a
arm required magnetostrictive measuring the underlying measuring tech- high-dynamic serial DyMoS®
• NOVOSTRICTIVE®, touchless process for direct, precise and nique mean that the system is interface with data transfer moni-
magnetostrictive measuring absolute measurement of linear highly resistant to shock and toring is offered.
process position in control, positioning and vibration.
• high-dynamic serial DyMoS®- measuring technology. The advantages of conventional
interface with data transmission The active sensing element is interfaces and bus interfaces have
monitoring The measurement is accom- encased in an aluminum housing been combined in Novotechnik’s
• non-contacting guiding with plished using a passive position rated to IP 67. This makes the DyMoS® interface. In addition to
floating position marker marker which can be moved as a transducer resistant to contami- the position value, the DyMoS®
• unlimited mechanical life free-floating or guided element. nation, dust, moisture and oils. interface also allows the actual
• no velocity limit for position traverse velocity to be sent.
marker Side coupling of the position Mounting is accomplished using The pulse interface also allows
• outstanding linearity perform- marker reduces the installation clamps that allow precise fully toleranced processing of
ance up to 30 µm envelope size, prevents the pump mechanical adjustment. both edges of the Start/Stop
• resolution up to 0.001 mm effect of slide arms and permits signal. As an option, the trans-
regardless of stroke length stroke lengths up to 4500 mm. A sophisticated ASIC in the trans- ducer can also be operated with
• analog interfaces have end-user ducer provides for standard multiple position markers.
output range programming The non-contact coupling version absolute output signals. In addi-
capability makes installation even simpler, tion to the familiar interfaces such Additional interfaces see separate
• low temperature coefficient and the wear-free operation as the synchronous serial inter- data sheet.
<20 ppm/K means unlimited mechanical life face (24 or 25 bits), the Start/
• insensitive to shock and expectancy and unlimited traverse
vibration speed of the position marker. Description
• optionally cable or plug The temperature coefficient of the Housing Anodized aluminium with metal end cap
connection transducer is extremely low due Mounting Compression clamps, longitudinally adjustable
• protection class IP67 / IP68 to the measuring principle, design Position marker Floating marker, plastic
and selected materials. guided marker, ball coupling
Measuring technique NOVOSTRICTIVE®, touchless magnetostrictive
Electrical connection 8-pin round connector, shielded, M12x1
8-pin round connector, shielded, IEC130-9
8-conductor cable, shielded, 1 m long
Electronics Integrated SMD with ASIC
Connect cable shield to housing
Novotechnik U.S., Inc.
155 Northboro Road
Southborough, MA 01772
Phone: 508-485-2244
Fax: 508-485-2430
Email: info@novotechnik.com
Connector pin Cable colors Connector with cable Start/Stop pulse interface SSI interface DyMoS® interface Analog interfaces
code 101, 102 code 201, 203, 205 EEM33-86, EEM33-87
PIN 6 BU PK supply voltage GND supply voltage GND supply voltage GND supply voltage GND
Phone: 508-485-2244
Fax: 508-485-2430
Email: info@novotechnik.com
Z-TLM-P01
Z-TLM-P04 Z-TLM-P05