Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
0% found this document useful (0 votes)
124 views6 pages

BKT 1 Anchor

Download as pdf or txt
Download as pdf or txt
Download as pdf or txt
You are on page 1/ 6

www.hilti.ae Profis Anchor 2.9.

3
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 9/19/2021
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HIT-HY 200-R V3 + HAS-U 8.8 M20
Return period (service life in years): 50
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef,act = 150 mm (hef,limit = - mm)
Material: 8.8
Evaluation Service Report: ETA 19/0601
Issued I Valid: 12/14/2020 | -
Proof: SOFA design method + fib (07/2011) - after ETAG BOND testing
Stand-off installation: eb = 0 mm (no stand-off); t = 20 mm
Anchor plate: lx x ly x t = 450 mm x 450 mm x 20 mm; (Recommended plate thickness: not calculated
Profile: Square hollow, 250 x 250 x 8,0; (L x W x T) = 250 mm x 250 mm x 8 mm
Base material: cracked concrete, C25/30, fc,cyl = 25.00 N/mm2; h = 250 mm, Temp. short/long: 30/40 °C
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement

R
- The anchor calculation is based on a rigid anchor plate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae Profis Anchor 2.9.3
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 9/19/2021
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads 3 4

Anchor reactions [kN]


Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 34.750 0.000 0.000 0.000
2 34.750 0.000 0.000 0.000 x
3 34.750 0.000 0.000 0.000 Tension
4 34.750 0.000 0.000 0.000

max. concrete compressive strain: - [‰]


max. concrete compressive stress: - [N/mm2]
resulting tension force in (x/y)=(0/0): 139.000 [kN] 1 2
resulting compression force in (x/y)=(0/0): 0.000 [kN]

Anchor forces are calculated based on the assumption of a rigid anchor plate.

3 Tension load SOFA (fib (07/2011), section 16.2.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 34.750 130.667 27 OK
Combined pullout-concrete cone failure** 139.000 143.021 98 OK
Concrete Breakout Strength** 139.000 149.026 94 OK
Splitting failure** 139.000 160.193 87 OK
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
196.000 1.500 130.667 34.750

3.2 Combined pullout-concrete cone failure


Ap,N [mm2] A0p,N [mm2] y A,Np
2
t Rk,ucr,25 [N/mm ] scr,Np [mm] ccr,Np [mm] cmin [mm]
640,000 202,500 3.160 15.00 450 225 225
2 0
yc t Rk,cr [N/mm ] max t Rk,cr [N/mm2] y g,Np y g,Np
1.020 7.14 7.50 1.072 1.008
ec1,N [mm] y ec1,Np ec2,N [mm] y ec2,Np y s,Np y re,Np
0 1.000 0 1.000 1.000 1.000
N0Rk,p [kN] NRk,p [kN] gM,p NRd,p [kN] NSd [kN]
67.310 214.532 1.500 143.021 139.000
Group anchor ID
1-4

3.3 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm]
640,000 202,500 3.160 225 450
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 1.000 1.000
k1 N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
7.700 70.729 1.500 149.026 139.000
Group anchor ID
1-4

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae Profis Anchor 2.9.3
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 9/19/2021
E-Mail:

3.4 Splitting failure


Ac,N [mm2] A0c,N [mm2] y A,N ccr,sp [mm] scr,sp [mm] y h,sp
640,000 202,500 3.160 240 480 1.184
h'ef [mm] c'cr,sp [mm] s'cr,sp [mm]
141 225 450
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N k1
0 1.000 0 1.000 1.000 1.000 7.700
N0Rk,c [kN] gM,sp NRd,sp [kN] NSd [kN]
64.203 1.500 160.193 139.000
Group anchor ID
1-4

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae Profis Anchor 2.9.3
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 9/19/2021
E-Mail:

4 Shear load SOFA (fib (07/2011), section 16.2.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* N/A N/A N/A N/A
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength* N/A N/A N/A N/A
Concrete edge failure in direction ** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (relevant anchors)

5 Displacements (highest loaded anchor)


Short term loading:
NSk = 25.741 [kN] dN = 0.273 [mm]
VSk = 0.000 [kN] dV = 0.000 [mm]
dNV = 0.273 [mm]
Long term loading:
NSk = 25.741 [kN] dN = 0.601 [mm]
VSk = 0.000 [kN] dV = 0.000 [mm]
dNV = 0.601 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

6 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid anchor plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility! 
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• Bore hole cleaning must be performed according to instructions for use (blow twice with oil-free compressed air (min. 6 bar), brush twice,
blow twice with oil-free compressed air (min. 6 bar)).
• Characteristic bond resistances depend on short- and long-term temperatures.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
• The compliance with current standards (e.g. EC3) is the responsibility of the user
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!
• The characteristic bond resistances depend on the return period (service life in years): 50

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae Profis Anchor 2.9.3
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 9/19/2021
E-Mail:

7 Installation data
Anchor plate, steel: - Anchor type and diameter: HIT-HY 200-R V3 + HAS-U 8.8 M20
Profile: Square hollow, 250 x 250 x 8,0; (L x W x T) = 250 mm x 250 Maximum installation torque: 0.150 kNm
mm x 8 mm
Hole diameter in the fixture: df = 22 mm Hole diameter in the base material: 22 mm
Plate thickness (input): 20 mm Hole depth in the base material: 150 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 194 mm
Drilling method: Hammer drilled
Cleaning: Compressed air cleaning of the drilled hole according to
instructions for use is required

7.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Compressed air with required • Dispenser including cassette and mixer
• Properly sized drill bit accessories to blow from the bottom of • Seismic/Filling set
the hole • Torque wrench
• Proper diameter wire brush
y

225 225

3 4 50

225
350

x
225

1 2
50

50 350 50

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -175 -175 225 575 225 575
2 175 -175 575 225 225 575
3 -175 175 225 575 575 225
4 175 175 575 225 575 225

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.ae Profis Anchor 2.9.3
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 9/19/2021
E-Mail:

8 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan

You might also like