Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

1 Input Data: WWW - Hilti.in

Download as pdf or txt
Download as pdf or txt
You are on page 1of 7

www.hilti.in Profis Anchor 2.8.

0
Company: Page: 1
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 27-03-2019
E-Mail:

Specifier's comments:

1 Input data
Anchor type and diameter: HST3-R M12 hef1
Seismic/Filling set or any suitable annular gap filling solution
Effective embedment depth: hef = 50 mm, hnom = 60 mm
Material: A4
Evaluation Service Report: ETA-98/0001
Issued I Valid: 09-02-2018 | -
Proof: SOFA design method + fib (07/2011) - after ETAG testing
Stand-off installation: eb = 0 mm (no stand-off); t = 20 mm
Anchor plate: lx x ly x t = 325 mm x 300 mm x 20 mm; (Recommended plate thickness: not calculated
Profile: no profile
Base material: cracked concrete, , fc,cyl = 28.60 N/mm2; h = 225 mm
Installation: hammer drilled hole, Installation condition: Dry
Reinforcement: no reinforcement or reinforcement spacing >= 150 mm (any Ø) or >= 100 mm (Ø <= 10 mm)
no longitudinal edge reinforcement
Reinforcement to control splitting according to fib (07/2011), 10.1.5.2 present

R
- The anchor calculation is based on a rigid baseplate assumption.

Geometry [mm] & Loading [kN, kNm]

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.8.0
Company: Page: 2
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 27-03-2019
E-Mail:

2 Load case/Resulting anchor forces y


Load case: Design loads
3 4
Anchor reactions [kN]
Tension force: (+Tension, -Compression)
Anchor Tension force Shear force Shear force x Shear force y
1 5.160 5.918 5.918 0.000
2 1.871 5.918 5.918 0.000 x
Tension Compression
3 5.160 5.918 5.918 0.000
4 1.871 5.918 5.918 0.000

max. concrete compressive strain: 0.08 [‰]


max. concrete compressive stress: 2.36 [N/mm2] 1 2
resulting tension force in (x/y)=(-73/0): 14.061 [kN]
resulting compression force in (x/y)=(149/0): 14.031 [kN]

Anchor forces are calculated based on the assumption of a rigid baseplate.

3 Tension load SOFA (fib (07/2011), section 10.1)


Load [kN] Capacity [kN] Utilization bN [%] Status
Steel Strength* 5.160 30.357 17 OK
Pullout Strength* N/A N/A N/A N/A
Concrete Breakout Strength** 14.061 26.451 54 OK
Splitting failure** N/A N/A N/A N/A
* anchor having the highest loading **anchor group (anchors in tension)

3.1 Steel Strength


NRk,s [kN] gM,s NRd,s [kN] NSd [kN]
42.500 1.400 30.357 5.160

3.2 Concrete Breakout Strength


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm]
90,000 22,500 4.000 75 150
ec1,N [mm] y ec1,N ec2,N [mm] y ec2,N y s,N y re,N
35 0.681 0 1.000 1.000 1.000
k1 N0Rk,c [kN] gM,c NRd,c [kN] NSd [kN]
7.700 14.560 1.500 26.451 14.061

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.8.0
Company: Page: 3
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 27-03-2019
E-Mail:

4 Shear load SOFA (fib (07/2011), section 10.2)


Load [kN] Capacity [kN] Utilization bV [%] Status
Steel Strength (without lever arm)* 5.918 24.880 24 OK
Steel failure (with lever arm)* N/A N/A N/A N/A
Pryout Strength** 23.670 107.937 22 OK
Concrete edge failure in direction x+** 11.835 17.379 69 OK
* anchor having the highest loading **anchor group (relevant anchors)

4.1 Steel Strength (without lever arm)


VRk,s [kN] gM,s VRd,s [kN] VSd [kN]
31.100 1.250 24.880 5.918

4.2 Pryout Strength


Ac,N [mm2] A0c,N [mm2] y A,N ccr,N [mm] scr,N [mm] k4
90,000 22,500 4.000 75 150 2.780
ec1,V [mm] y ec1,N ec2,V [mm] y ec2,N y s,N y re,N
0 1.000 0 1.000 1.000 1.000
N0Rk,c [kN] gM,c,p VRd,cp [kN] VSd [kN]
14.560 1.500 107.937 23.670

4.3 Concrete edge failure in direction x+


lf [mm] dnom [mm] kV a b
50 12.0 1.700 0.043 0.053
c1 [mm] Ac,V [mm2] A0c,V [mm2] y A,V
275 2,30,625 3,40,313 0.678
y s,V y h,V y a,V ec,V [mm] y ec,V y re,V y 90°,V
1.000 1.354 1.000 0 1.000 1.000 2.000
V0Rk,c [kN] n1 gM,c VRd,c [kN] VSd [kN]
56.818 2 1.500 17.379 11.835
Note: Resistance limit acc. to fib (07/2011) Eq. (10.2-6) is governing

5 Combined tension and shear loads SOFA (fib (07/2011), section 10.3)
bN bV a Utilization bN,V [%] Status
steel 0.170 0.238 2.000 9 OK
concrete 0.532 0.681 1.500 95 OK

baN + baV <= 1

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.8.0
Company: Page: 4
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 27-03-2019
E-Mail:

6 Displacements (highest loaded anchor)


Short term loading:
NSk = 1.386 [kN] dN = 0.091 [mm]
VSk = 8.767 [kN] dV = 1.921 [mm]
dNV = 1.923 [mm]
Long term loading:
NSk = 1.386 [kN] dN = 0.363 [mm]
VSk = 8.767 [kN] dV = 2.857 [mm]
dNV = 2.880 [mm]

Comments: Tension displacements are valid with half of the required installation torque moment for uncracked concrete! Shear displacements
are valid without friction between the concrete and the anchor plate! The gap due to the drilled hole and clearance hole tolerances are not
included in this calculation!

The acceptable anchor displacements depend on the fastened construction and must be defined by the designer!

7 Warnings
• The anchor design methods in PROFIS Anchor require rigid anchor plates per current regulations (ETAG 001/Annex C, EOTA TR029, etc.).
This means load re-distribution on the anchors due to elastic deformations of the anchor plate are not considered - the anchor plate is
assumed to be sufficiently stiff, in order not to be deformed when subjected to the design loading. PROFIS Anchor calculates the minimum
required anchor plate thickness with FEM to limit the stress of the anchor plate based on the assumptions explained above. The proof if the
rigid base plate assumption is valid is not carried out by PROFIS Anchor. Input data and results must be checked for agreement with the
existing conditions and for plausibility! 
• The accessory list in this report is for the information of the user only. In any case, the instructions for use provided with the product have to
be followed to ensure a proper installation.
• The design method fib (07/2011) assumes that no hole clearance between the anchors and the fixture is present. This can be achieved by
filling the gap with mortar of sufficient compressive strength (e.g. by using the HILTI Seismic/Filling set) or by other suitable means
• The compliance with current standards (e.g. EC3) is the responsibility of the user
• Checking the transfer of loads into the base material is required in accordance with fib (07/2011)!

Fastening meets the design criteria!

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.8.0
Company: Page: 5
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 27-03-2019
E-Mail:

8 Installation data
Anchor plate, steel: - Anchor type and diameter: HST3-R M12 hef1
Profile: no profile Installation torque: 0.060 kNm
Hole diameter in the fixture: df = 14 mm Hole diameter in the base material: 12 mm
Plate thickness (input): 20 mm Hole depth in the base material: 70 mm
Recommended plate thickness: not calculated Minimum thickness of the base material: 100 mm
Drilling method: Hammer drilled
Cleaning: Manual cleaning of the drilled hole according to instructions for use is required.

8.1 Recommended accessories

Drilling Cleaning Setting


• Suitable Rotary Hammer • Manual blow-out pump • Hilti SIW 22T-A impact screw driver
• Properly sized drill bit • Seismic/Filling set
• Torque wrench
• Hammer
y
162

163 163

50
3 4

150
200

x
150

1 2
50

50 150 125

Coordinates Anchor [mm]


Anchor x y c-x c+x c-y c+y
1 -113 -100 - 275 - -
2 38 -100 - 125 - -
3 -113 100 - 275 - -
4 38 100 - 125 - -

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
www.hilti.in Profis Anchor 2.8.0
Company: Page: 6
Specifier: Project:
Address: Sub-Project I Pos. No.:
Phone I Fax: | Date: 27-03-2019
E-Mail:

9 Remarks; Your Cooperation Duties


• Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas
and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be
strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted
prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the
data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be
put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly
with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an
aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or
suitability for a specific application.
• You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for
the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do
not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software
in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or
damaged data or programs, arising from a culpable breach of duty by you.

Input data and results must be checked for agreement with the existing conditions and for plausibility!
PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan
HST3 (-R) subject to:
Anchor size M8 M10 M12 M16 M20 M24
Hammer drilling*

TE2(-A) – TE30(-A) TE40 – TE70

Diamond core drilling*

DD-30W, DD-EC1

Setting tool*
Setting tool HS-SC -

Hollow drill bit drilling*

- TE-CD, TE-YD

Seismic Set/ Filling Set**

Seismic/Filling Set M8-M20 (Carbon and Stainless Steel A4) -

*Installation methods provided in ETA-98/0001


**Seismic set needed to fill the annular gap between anchor and fixture:
No annular gap, double design resistance (agap=1)

You might also like