Ab/Abd Air Boosters & Systems
Ab/Abd Air Boosters & Systems
Ab/Abd Air Boosters & Systems
The principle of the air booster works much the same as our liquid pumps in which a
larger air drive piston is directly connected to a smaller pumping piston. The incoming
air from the compressor drives the booster and also feeds the supply to the unit.
Pressures can be boosted up to 500 psi on the single-acting AB-
4 and as much as 850 psi on our double-acting ABD-5.
All SC air boosters are pre-lubricated at the factory and should not be used with
inline air lubricators. Clean, dry air is very important as any grit, moisture, or foreign
matter in the air supply can damage the high pressure components. A coalescing
filter is recommended before the air supply and air drive inlet, which can be the same.
Typically, air boosters are used to build up pressures for static holding applications. Under normal,
intermittent duty, the air cycling valve should be inspected and re-lubricated after 500,000 cycles. For
continuous operation the booster should not be operated at more than 40 cycles per minute and should
be inspected and re-lubricated every 150,000 cycles or 60 operating hours.
Typical Applications
Contact us direct, or one of our qualified distributors, with your specific requirements
and let us help you with any of your air booster applications.
AB-2 & AB-4 SERIES
The AB Series air booster is a compact,
5.17"
single-acting unit available in 2:1 or 4:1
ratios. This booster is an inexpensive 4.52" 3.00"
160
Air Output Flow (Vo) - Liter/Min.
Air Output Flow (Vo) - Liter/Min.
80 PSI
Air Output Flow (Vo) - SCFM
100 125
5 140
4
120 100
4 60 PSI 75
100 3
3 75
80 50
40 PSI
2
2 60 50
40
1
1 25
20
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 0 50 100 150 200 250 300 350 400 450 500
Outlet Pressure (P O) - PSIG Outlet Pressure (P0) - PSI
ABD-2 & ABD-5 SERIES
The ABD-2 and ABD-5 are double-acting, single stage air boosters
in 2:1 and 5:1 ratios. These boosters can supply equipment with
added air pressure when plant supplies are depleted due to
overuse or under-sizing. The volume available from the boosters is
ample for most equipment applications or units can be paralleled for
additional capacity.
5 10 15 20 0 10 20 30 40 50
100 40
Pa=Ps=150 PSI VA = 87 VA=90
Pa=Ps=150 PSI ABD-5
CPM = 94 ABD-2 2.5 35 1.0
CPM=215
Air Output Flow (Vo) - Cu. Meter/Min.
125 PSI
90 84 2.0 247
72 25
100 PSI 75 75
60
100 PSI
86 70 231 81
1.5 20 73
64 55 66 188
75 PSI 66 75 PSI 185 0.5
40 40 218
15 66
80 44 1.0
49 183
43
39 41 10 38
20 45 21
20 0.5 119
35 5 13 16
11
0 0.0 0 0.0
50 100 150 200 250 300 0 100 200 300 400 500 600 700 800
Outlet Pressure (P0) - PSI Outlet Pressure (P 0) - PSI
ABD-2 SERIES
19.62"
9.83"
8.18" 6.70"
2.05" 2.52"
12.65"
8.31"
3.56"
ABD-5 SERIES
17.38"
9.07"
7.79"
AIR DRIVE
3/4" NPT
10.66"
8.32"
4.69"
.31"
7.43" 3.00"
8.43" 5.95"
18.97"
AB-2 & AB-4 SYSTEMS
12.50"
AIR INLET
1/4" NPT
1 2 3 4 5 6 7
14.00" 10 29.88"
AIR OUTLET
1/2" NPT
(1) Tank Drain
(2) ABD-2 Air Booster 7
(3) Inline Filter
(4) Ball Valve 6
(5) Muffler
(6) Safety Relief Valve 37.56"
5
(7) 15 Gallon ASME
Receiver 31.13"
11.91" 3
10.88" 1 25.15"
ABD-5 SYSTEM
The S10320-ABD-5 System combines the
rugged 5:1 ratio, single-stage, double acting
booster with a 600 PSI ASME reservoir for
high pressure applications needing a five
gallon reserve.
21.50" 10 22.25"
AIR OUTLET
1/4" NPT 9
7
SC
24.16" 5
18.76"
4
3
9.52"
2
1
AIR INLET
1/2" NPT
DESIGNER AND MANUFACTURER OF HYDRAULIC AND PNEUMATIC EUIPMENT
CUSTOMER E-MAIL
ADDRESS PHONE
DIAGRAM OF APPLICATION
HOW TO ORDER TABLE
10320 - - -
5:1 Ratio
4:1 Ratio
13
SC Hydraulic Engineering – 1130 Columbia St. – Brea, CA 92821 – Tel 714-257-4800 – Fax 714-257-4810 – www.schydraulic.com
Manufactured in the United States