Integral Pilot (External Exhaust) Threaded or Quick Mount Connection 3/4 To 1 1/2
Integral Pilot (External Exhaust) Threaded or Quick Mount Connection 3/4 To 1 1/2
Integral Pilot (External Exhaust) Threaded or Quick Mount Connection 3/4 To 1 1/2
2/2
Series
integral pilot (external exhaust)
threaded or Quick Mount connection 353
3/4 to 1 1/2
FEATURES
• The piston cartridge pulse valves are especially designed for dust collector
service applications, combining high flow, long life and extremely fast opening and
closing to produce reliable and economical operation
• The angle bodies and special piston cartridge result in unique operating features
required for dust collector service applications
• The high quality polyacetal (POM) piston cartridge guarantees a long operating
life and a large temperature range
• The design with Quick Mount connections eliminates the time consuming thread
cutting and sealing resulting in maximum flexibility while the valve will be
anchored to the pipes
• Built-in silencers reduce noise and prevent foreign particles from entering the valve
• The integral operators are provided with epoxy moulded F-class coils. Various
optional waterproof and explosionproof solenoids for use in potentially explosive
atmospheres (gas & dust) according to Directive ATEX 94/9/EC can be mounted
on the same basic valve (see pages 49 to 57)
• The components satisfy all relevant EC directives
General
Differential pressure (PS) 0,3 - 8,5 bar [1 bar = 100kPa]
Ambient temperature range -20 to +85°C
fluid temperature range (TS) piston
air -20 to +85°C POM (polyacetal)
CONSTRUCTION
Body Aluminium
Bonnet Aluminium
Quick Mount clamps Steel
Bolts Steel
Core tube Stainless steel
Core and plugnut Stainless steel
Core spring Stainless steel
Sealings & disc NBR (nitrile)
Piston/cartridge POM (polyacetal) / NBR (nitrile)
Shading coil Copper
Coil insulation class F
Connector Spade plug (cable Ø 6 - 8 mm)
Connector specification 3 x DIN 46244
Electrical safety IEC 335
ELECTRICAL CHARACTERISTICS
Standard voltages DC (=) : 24V
(Other voltages and 60 Hz on request) AC (~) : 24V - 115V - 230V / 50 Hz
nominal power ratings ambient
coil inrush holding hot/cold temperature
Availability, design and specifications are subject to change without notice. All rights reserved.
protection
type ~ ~ = range
(VA) (VA) (W) (W) (°C)
CM22-FB 14,5 11 6,3 -
-20 to +85 moulded IP65
CM22-FI (1) - - - 15 / 22
SPECIFICATIONS
operating pressure
flow
orifice differential (bar) catalogue
pipe coefficient coil type Quick Mount
size max. (PS) number
size Kv clamps
min. air
(mm) (m3/h) (l/min) ~/= ~ = (1) standard ATEX dust II3D
(G*) - Threaded pipe connection
3/4 20 14 233 0,3 8,5 CM22-FB CM22-FI SC E353A811 SCDU E353A811 -
1 25 23 383 0,3 8,5 CM22-FB CM22-FI SC E353A821 SCDU E353A821 -
1 1/2 40 46 768 0,3 8,5 CM22-FB CM22-FI SC E353A831 SCDU E353A831 -
(Ø) - Quick Mount connection on inlet
3/4 20 14 233 0,3 8,5 CM22-FB CM22-FI SC S353A811 SCDU S353A811 C117-281
1 25 23 383 0,3 8,5 CM22-FB CM22-FI SC S353A821 SCDU S353A821 C117-282
1 1/2 40 46 768 0,3 8,5 CM22-FB CM22-FI SC S353A831 SCDU S353A831 C117-290
(Ø) - Quick Mount connection on inlet & Outlet
X003GB-2009/R8
3/4 20 14 233 0,3 8,5 CM22-FB CM22-FI SC S353A711 SCDU S353A711 C117-281
1 25 23 383 0,3 8,5 CM22-FB CM22-FI SC S353A721 SCDU S353A721 C117-282
1 1/2 40 46 768 0,3 8,5 CM22-FB CM22-FI SC S353A731 SCDU S353A731 C117-290
(1) Intermittent duty, Relative Duty Time is 10%. Max. on time 1 min.
All leaflets are available on: www.asconumatics.eu
X003-5
SOLENOID VALVES SERIES 353
OPTIONS
● Waterproof enclosure with embedded screw terminal coil according to protection class IP67, CEE 10.
● Explosionproof solenoids for hazardous locations according to “ATEX” and national standards.
● Explosionproof and watertight solenoids according to “NEMA” standards.
● Plug with visual indication and/or peak voltage suppression.
● Electronic timer.
INSTALLATION
● The valves can be mounted in any position without affecting operation.
● Pipe connection identifiers are: G*= combination thread according to ISO 228/1 and ISO 7/1 or Ø for Quick Mount.
● For Quick Mount types tightness is achieved by the O-ring sealing on the pipes (3/4"=Ø26,4 to 27,4 and 1"=Ø33,2 to 34,2
and 1 1/2"=Ø47,8 to 48,8) according to ISO 4200.
● Other pipe threads are available on request.
● Installation/maintenance instructions are included with each valve.
● Spare parts kit and replacement coils are available.
360 360
G
E H
Fig. 1: Threaded type Fig. 2: Quick Mount type (inlet only)
A F
Availability, design and specifications are subject to change without notice. All rights reserved.
B
C
D
G
E H
Fig. 3: Quick Mount type (inlet & outlet)
special diaphragm assemblies give the unique operating features required for dust
collector service applications
• Integral compression fittings for fast, easy, secure installation
• Built-in silencers reduce noise and prevent foreign particles from entering the valve
• The integral operators are provided with epoxy moulded F-class coils. Various optional
waterproof and explosionproof solenoids for use in potentially explosive atmospheres
(gas & dust) according to Directive ATEX 94/9/EC can be mounted on the same basic
valve (see pages 49 to 57)
• The valves satisfy all relevant EC directives
GENERAL
Differential pressure (PS) 0,35 - 8,5 bar [1 bar = 100kPa]
Ambient temperature range -20 to +85°C
fluids () temperature range (TS) diaphragm ()
SPECIFICATIONS
operating pressure
flow differential (bar) prefix optional solenoids
pipe orifice catalogue
coefficient
size size max. (PS) number
Kv
FPM
OPTIONS
• Waterproof enclosure with embedded screw terminal coil according to protection class IP67, CEE 10
• Explosionproof solenoids for hazarous locations according to ATEX and national standards
• IECEx certification
• Compliance with “UL” standards
• Plug with visual indication and/or peak voltage suppression
• Electronic timer
• Valves can also be supplied with FPM (fluoroelastomer) diaphragms and seals. Use the appropriate optional suffix letter for
identification
INSTALLATION
• The valves can be mounted in any position without affecting operation
• Threaded pipe connection is G (ISO 228/1) or compression fitting
• For compression fitting types tightness is achieved by the compressed gasket on the blow tube
• The use of the rubber gaskets as sealing members will allow a slight misalignment in piping when using compression fittings
• Other pipe threads are available on request
• Installation/maintenance instructions are included with each valve
• Spare parts kits and replacement coils are available
360
H
H K K
J J
IN
D
E D
E
Fig. 1: Threaded pipe connection - aluminium Fig. 2: Compression type fitting - aluminium
Availability, design and specifications are subject to change without notice. All rights reserved.
● The high quality diaphragms are reinforced and wear resistant to guarantee a long
operating life, even under harsh conditions
• The integral operators are provided with epoxy moulded F-class coils. Various
optional waterproof and explosionproof solenoids for use in potentially explosive
atmospheres (gas & dust) according to Directive ATEX 94/9/EC can be mounted
on the same basic valve (see pages 49 to 57)
• The valves satisfy all relevant EC directives
GENERAL
Differential pressure (PS) 0,35 - 8,5 bar [1 bar = 100kPa]
Ambient temperature range -20 to +85°C
fluids () temperature range (TS) diaphragm ()
SPECIFICATIONS
operating pressure
flow differential (bar) prefix optional solenoids
pipe orifice catalogue
coefficient
size size max. (PS) number
Kv
FPM
l : Available feature
(1) Contains spring above the main diaphragm (2) Threaded pipe connection is external (male thread)
OPTIONS
• Waterproof enclosure with embedded screw terminal coil according to protection class IP67, CEE 10
• Explosionproof solenoids for hazardous locations according to ATEX and national standards
• IECEx certifcation
• Hose connection executions (3" only)
• Compliance with “UL” standards
• Plug with visual indication and/or peak voltage suppression
• Electronic timer
• Valves can also be supplied with FPM (fluoroelastomer) diaphragms and seals. Use the appropriate optional suffix letter for
identification
INSTALLATION
• The valves can be mounted in any position without affecting operation
• Threaded pipe connection is G (ISO 228/1) or compression fitting
• For compression fitting types tightness is achieved by the compressed gasket on the blow tube
• The use of the rubber gaskets as sealing members will allow a slight misalignment in piping when using compression fittings
• Other pipe threads are available on request
• Installation/maintenance instructions are included with each valve
• Spare parts kits and replacement coils are available
360
360
Fig. 1: Threaded pipe connection - aluminium Fig. 2 Compression type fitting - aluminium
360°
Availability, design and specifications are subject to change without notice. All rights reserved.
Fig. 3: External threaded type - aluminium Fig. 4: Threaded pipe connection - stainless steel
SC(DU) G353-051 80 50 30 95 168 165 45 G 3/4 165 210 227 2,6 Fig. 1
SC(DU) G353-060 80 50 30 143 240 192 45 G 1/2 165 258 275 4,1 Fig. 2
SC(DU)G353A065 80 50 30 117 177 136 45 G 3/8 131 225 242 1,75 Fig. 3
SC(DU)G353A134 80 50 30 71 130 136 45 G 3/8 131 161 178 2,5 Fig. 4
(1) Incl. coil and connector (C) Construction type
All leaflets are available on: www.asconumatics.eu
X003-10
POWER PULSE 2/2
Series
TANK SYSTEM (Ø160) NC 355
integral pilot
1
FEATURES
● Power Pulse Tank System using aluminium profile and end covers with CE ap-
proval according to Directive 97/23/EC for Pressure Equipment
● Full immersed valve system with special springless piston/diaphragm design
offers highest peak pressure and best flow performance operating features requi-
red for dust collector applications
● The high quality TPE piston/diaphragm guarantees a long operating life and a large
temperature range
● Possibility to apply different combinations of pitch distances and upto 24 valves
● Easy to connect to other tank systems. Service connections for different accesso-
ries such as: filter regulator, pressure gauge, safety valve and automatic/manual
drain valve
● Several blow pipe connections available, such as: Quick Mount, push-in, hose or
threaded
● Built-in silencers reduce the noise and prevent foreign particles from entering the
valve
• The integral operators are provided with epoxy moulded F-class coils. Various
optional waterproof and explosionproof solenoids for use in potentially explosive
atmospheres (gas & dust) according to Directive ATEX 94/9/EC can be mounted
on the same basic valve (see pages 49 to 57)
GENERAL
Differential pressure (PS) 0,3 to 8,5 bar [1 bar = 100 kPa]
Ambient temperature range -20°C to +85°C
Tank System
volume 0,20 dm3 per cm tank
recommended min. tank volume 10 dm3 (equals to 500 mm tank length)
min. pitch distance 120 mm
maximum length 3000 mm
min. pulse time 50 ms
CONSTRUCTION
Tank Anodized aluminium
Adapter/body Aluminium
Clipring Stainless steel
Clamps Stainless steel
Bolts (clamps) Stainless steel
Core tube Stainless steel
Availability, design and specifications are subject to change without notice. All rights reserved.
ELECTRICAL CHARACTERISTICS
Standard voltages DC (=) 24V
(Other voltages and 60 Hz on request) AC (~) 24V - 115V - 230V/50Hz
ORDERING INFORMATION - for example: SC E355A J 06 (Specify Voltage/Hz) + Dimension code (specified on next page)
SC (DU) E 3 5 5 A J 0 6 (1)
64
52
r q 17
IEC 335/IP65 (II 3 D)
WP (WPDU)
r q K 64
52
IEC 335/IP67 (II 3 D) 37
r q
II 2 G Ex d IIC, II 2 D Ex td A21IP67 (2)
L
37
9
Availability, design and specifications are subject to change without notice. All rights reserved.
r q
II 2 G Ex e mb II, II 2 D Ex tD (2)
M
34
9
PV
Male threaded connection (R1")
r q
II 2 G Ex mb II, II 2 D Ex m D21(2)
EF
X003GB-2009/R8
Type 7 and 9
(1)
Specify required number of valves between 01 and 24
(2)
Exact temperature class depends on wattage and max. ambient temperature (see also page 48 to 56)
36
Pressure
supply
G1"
325
268
145
Service
Availability, design and specifications are subject to change without notice. All rights reserved.
connection
G¼" 140
Fig. 2 (side view) 78
38
52 35 110
22 180
217
174
Ø45
X003GB-2009/R8
46,5
A B C D A
INSTALLATION
● Tank system can be mounted in any position using the standard brackets integrated in the end cap (M12 bolts
recommended) without affecting operation
● Pipe connection identifier is: R = according to ISO 7/1, G = according to ISO 228/1 or Ø for other outlet connections
● For Quick Mount types tightness is achieved by the O-ring sealing on the pipe (1" = Ø33,2 to 34,2) according to ISO 4200
● Installation/maintenance instructions and declaration of conformity are included with each tank system
● Spare valves, spare parts kits and coils are available
100
166
Ø 99 G1"
SPECIFICATIONS Availability, design and specifications are subject to change without notice. All rights reserved.
FEATURES
● Tank system using aluminium profile and end covers with CE approval according
to Pressure Equipment Directive 97/23/EC, modules B1+D
● For use in dust collector applications requiring high flow capacity and accurate
process control
● Full immersed valve system with polychloroprene (CR) diaphragm design offers
● Easy to connect to other tank systems. Service connections for different accessories
such as: filter regulator, pressure gauge, safety valve and automatic/manual drain
valve
● Several blow pipe connections available, such as: Quick Mount, push-in, hose or
GENERAL
Pressure inlet connection ISO 228/1, G 1 1/2" female
Air operating pressure min. 1,0 max. 8,0 bar
Safety pressure 12,2 bar
Flow rate Kv 43,3 = 724 l/min
Ambient temperature range -20°C to +85°C
Tank System
volume 0,314 dm3 / cm
recommended min. tank volume 15 dm3
min. pitch distance end cap 110 mm for bracket 120 mm;
between valve 160 mm
maximum length 3000 mm
The tank system can be mounted in any position without affecting operation
fluids temperature range (TS) diaphragm
air -20 to +100 °C CR (polychloroprene)
CONSTRUCTION
Tank Anodised aluminium profile EN AW-6060 T66
Valve, outlet adapter Die-cast aluminium GD-ALSi12 to EN 1706
End caps Die-cast aluminium GD-ALSi12 to EN 1706
Spring Stainless steel
Availability, design and specifications are subject to change without notice. All rights reserved.
Plugs PA (polyamide)
Sealings & disc NBR (nitrile)
Screws Steel 8.8
Diaphragm CR (optionally FPM or TPE)
Mounting brackets stainless steel AISI 304 (1.4301)
Shading coil Copper
ELECTRICAL CHARACTERISTICS
Coil insulation class F
Connector Spade plug (cable Ø 6-10 mm)
Connector specification 3 x DIN 46244
Electrical safety IEC 335
Standard voltages DC (=) : 24V
(Other voltages and 60 Hz on request) AC (~) : 24V - 120V - 230V / 50 Hz
nominal power ratings operator
coil inrush holding hot/cold temperature
protection
type ~ ~ = range (TS)
(VA) (VA) (W) (W) (°C)
DP14258GB-2013/R01
CMXX-FT 55 23 10,5 -
-20 to +85 moulded IP65
CMXX-FF - - - 14 / 19,7
Availability, design and specifications are subject to change without notice. All rights reserved.
OUTLET CONNECTION TYPES
K = Push-in with clamps W = Push-in without clamps U = Male hose connection M = Male thread connection F = Female thread connection
ORDERING INFORMATION
Pressure
supply
Optional
Service
connection A P1 P2 P3 P4 B
-1,0 mm ±0,5 mm ±0,5 mm ±0,5 mm ±0,5 mm -1,0 mm
Example I: Dimension code for a 5 solenoid operated valve 24 DC tank system with push-in outlet:
Start distance A = 125 mm
Standard pitch P = 1+2+3+4 = 175 mm
End distance B = 125 mm
Total dimension 950 mm
Weight 27 kg
Volume 26 l
Order number G355B8W5S0015F1
Availability, design and specifications are subject to change without notice. All rights reserved.
ORDERING INFORMATION
Remote double staged operated valve system prepared for pilot box
including pilot box mounting brackets, push-in fittings and tubes for G 1/8" pilot box series 110
Fig. 1 (front view) Fig. 2 (side view)
Space for:
190 mm for 6 pilot valve box
328 mm for 12 pilot valve box
Optional
Pressure
supply
Service
connection A P1 P2 P3 P4 P5 B
-1,0 mm ±0,5 mm ±0,5 mm ±0,5 mm ±0,5 mm ±0,5 mm -1,0 mm
Example II: Dimension code for a 6 double remote operated valve tank system prepared for pilot box with clamp outlet:
Availability, design and specifications are subject to change without notice. All rights reserved.
For technical information on ASCO pilot boxes see catalogue series 110
For assistance please consult our website: www.asconumatics.eu
OPTIONS
● Special customised executions
● Valve can be supplied with FPM (fluoroelastomer) and TPE (thermoplastic polyester elastomer) diaphragms.
● Waterproof enclosures with embedded screw terminal coil according to protection class IP67, CEE 10
● Explosionproof solenoids for hazardous locations according to "ATEX" and national standards
● Explosionproof and watertight solenoids according to "NEMA" standards
● Separate Quick Mount clamps for outlet connection; kit number: C117-290
INSTALLATION
● The tank system can be mounted in any position using the standard brackets (M8 bolts recommended) without affecting
operation.
● Pipe connection identifier is: G = according to ISO 228/1 and ISO 7/1, or Ø for other outlet connections
● For Quick Mount types tightness is achieved by the O-ring sealing on the pipe (1 1/2" = Ø47,8 to 48,8) according to
ISO 4200.
● When connecting piping or tubing to the G 1/8" or G 1/4” connection in the valve bonnet, the remote ASCO pilot valve should
be mounted as close as possible to the main pulse valve. Connection tubing lengths of 3 meters or less have little effect on
DP14258GB-2014/R01
the pulse response. Installations with over 3 meters of tubing must be tested under actual operating conditions. Tubing with
Ø6 or Ø8 mm O.D. is recommended for all installations.
● Installation/maintenance instructions and declaration of conformity are included with each tank system.
● Spare parts kits and coils are available.
General
Differential pressure (PS) 0,35 to 8 bar [1 bar = 100kPa]
Ambient temperature range -10 to +80°C
CONSTRUCTION
Tank Steel, grey
Bonnet Aluminium
Bolts Stainless steel
Core tube Stainless steel
Core and plugnut Stainless steel
Spring Stainless steel
Sealing & discs NBR (nitrile)
Diaphragm CR (chloroprene)
Shading coil Copper
Coil insulation class F
Connector Spade plug (cable Ø 6-10mm)
Connector specification ISO 4400
Electrical safety IEC 335
ELECTRICAL CHARACTERISTICS
Standard voltages DC (=) : 24V - 48V;
(Other voltages and 60 Hz on request) AC (~) : 24V - 48V - 115V - 230V / 50Hz
CMXX-FT 55 23 10,5 -
moulded IP65
CMXX-FT - - - 14 / 19,7
SPECIFICATIONS
operating pressure
pipe orifice flow coefficient differential (bar)
catalogue number
size size Kv max. (PS)
min air
(mm) (m3/h) (l/min) ~/= hose threaded
8" Tank System
1 1/2" 40 46 768 0,35 8 SCG357ANxx (1) (2) SCG357AOxx (1) (2)
(1)
Standard tank has round ends. For flat ends use suffix FE
(2)
xx indicates the number of valves
X003GB-2014/R01
ORDERING
Example: Dimension code for a 4 valves tank system: ORDERING EXAMPLE TANK SYSTEM:
Tank diameter 8" SCG357AN 04 (*)
24 V/DC + 170 180 D200
Operator SC, 24V/DC
Pipe size 1 1/2" deviating pitch
Connection Hose (see fig. 1: Connection Type)
standard pitch
Number of valves 4 pcs
Start and End distance 170 mm start & end dist.
Standard pitch 180 mm voltage
Deviating pitch Between valve no. 3 and no. 4 tank end type
is position D (see fig. 1) 200 mm no. of valves
Catalogue number SCG357AN04 24V/DC catalogue no.
Dimension code 170180D200
DIMENSIONS (mm)
A B C D A A
HOSE THREADED
G G
CERT. PLATE
F
F
F
ØE
80
80
40
ØH
1/4" GAS FEMALE (3x) Flat ends (Suffix "FE")
Fig.1
F
Connection Type
A B/C/D A
tank min. start distance minimum pitch min. end distance
fig. ØE F G Ø H
diameter
(round) (flat) (round) (flat) (round) (flat)
8" 1 170 118 160 160 170 118 218,1 G 1 1/2" 70 18 48,3
() For standard tank (round ends) use no suffix, for flat ends use suffix FE
Availability, design and specifications are subject to change without notice. All rights reserved.
MOUNTING BRACKETS E
Ø13
C
E
H
G
B
Ø13
H
G
F Ø13 F D
C
Fig.2 - Contra bracket Fig.3 - Bracket
tank tank
fig. C ØE F G H fig. B C D ØE F G H
diameter diameter
8" 2 348 284 50 8 110 8" 3 210 348 200 284 50 8 110
INSTALLATION
• Tank System can be mounted in any position. We can supply standard mounting brackets with each tank by specifying suffix
X003GB-2014/R01