Axe Microprocess 5 Digital Panel Meter: Key Introduce Operation Manual

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

AXE MICROPROCESS 5 DIGITAL PANEL METER (Low Power)(24*48mm) MMS-H Series

■ Features
◎ Measuring DCA/DCV/ACA/ACV/Potentiometer/Pt-100/Transmitter/Load Cell/Resistor….etc
◎ Accuracy 0.05% F.S.±1 digit ◎
EEPROM Saving, data safekeeping about 10 years
◎ Display range -19999~19999 can be modified ◎
Man-machine interface ,easy to operate
◎ Decimal point can be modified ◎
M Modified inside parameter, must have pass code
◎ Display average can be modified(1~99) ◎
CE Certification
■ Name Of Parts
Display


ENT   
E Set-value down (Display
DSPAN DZERO
zero adjustment call out)

Parameter ENTER (Function call out) Set-value up (Display span adjustment call out)
Cursor shift

Key Introduce Operation Manual


Key Function 1.In normal display the key function is call out parameter setting page
2.In parameter setting page the key function is data enter and go to next page
Key Function In parameter setting page the parameter mark & data is alternate display. If need modify data can
press shift key into setting procedure. The display is lock parameter data this time must let off key
about 0.2 sec press again the cursor (twinkle express) is cycle moving left/right. (key response
about 0.2 sec)
Key Function In parameter setting page the parameter mark & data is alternate display. If need modify data can
press up key into setting procedure. The display is lock parameter data this time must let off key
about 0.2 sec press again the parameter data will increment. (key response about 0.2 sec)
Key Function Into parameter setting page, the parameter mark & data is alternate display, If need modify data
can press down key into setting procedure, The display is lock parameter data, this time must let
off key about 0.2 sec, press again the parameter data will decrement. (Key Response about 0.2 sec)
&Key Function  
In setting group or setting page press & key return normal display, but if in setting page the
modify data will be lost
No Key in anything In setting page no key in anything about 2 minutes return normal display
Step Parameter Mark Description Parameter Mark Operation Manual
1
Normal display
  Press /FUNC key into P.COD setting page
in 5 digit pass code with && key
2
P.COD(Pass code input page)
 1.Key
2.Press key, the pass code is right, into DP setting page, otherwise
 return to normal display
3 DP(Decimal Point)  1. Decide decimal point position with & key (0 to 4)
Default=0  2. Press key enter data and into DSPL setting page
4 DSPL(Display Low Scale)  1.Decide display low scale with && key (-19999~19999)
Default=0  2.Presskey enter data and into DSPH setting page
5 DSPH(Display High Scale)  1.Decide display high scale with && key (-19999~19999)
Default=99999  2.Presskey enter data and into AVG setting page
6 AVG (Average)  1.Decide display Average times with && key (1~99)
Default=5  2.Presskey enter data and into LCUT setting page
7 LCUT (Low Cut)  1.Decide display low cut with && key (0~99)
Default=0  2.Presskey enter data and into CODE setting page
8 CODE(Pass Code)  1.Decide Pass code with &&key (0~19999)
Default=0  2.Presskey enter data and return to normal display
Step Parameter mark description Parameter mark Operation manual
9 Normal display  Press /DZERO key about 3 sec, into DZERO adjustment page
9-1 DZERO(Display Zero Adjust  1.Adjustment display zero with  or  key
)Default=0  2.Press  key enter data and return to normal display
Step Parameter mark description Parameter mark Operation manual
10 Normal display  Press /DSPAN key about 3 sec, into DSPAN adjustment page
10-1 DSPAN(Display Span Adjust  1.Adjustment display span with  or  key
)Default=0  2.Press  key enter data and return to normal display
Appendix Error Mark Description Error Mark Analyze & Description
1 Input over error detect  Input signal over range (120%)
2 Input under error detect  Input signal under range (-20%)
3 Display over error detect  Display over range(99999)
4 Display under error detect  Display under range(-19999)
5 A/D Converter error detect  1. Input signal over range (180%)
2. Inside circuit damage
Please moving input signal if still display ADER, please contact us
6 EEPROM error detect  1.External interference when EEPROM read/write
 2.EEPROM write over 100 million times(guarantee 10 years)
 Please power reset, if still display E-00,doing following step:

  
1. E-00 & No alternate display for inquire reset EEPROM
2. Decide Yes with or key, press key return normal display
3.EEPROM was reset, Please follow step 1~10 set again
MMS-H Calibrate Step

Step Parameter Mark Description Parameter Mark Operation Manual


1 Normal display  1.Press & key about 3sec.,into INLO setting page
2 INLO(Input low calibrate  1.Input low signal and press  key read calibrate value
setting page)  2.Wait display stability ,press  key enter data and into
INHI setting page
3 INHI(Input high calibrate  1.Input high signal and press  key read calibrate value
setting page)  2.Wait display stability , Press  key enter data and into
DP setting page