Autonics Panels MP5W Data Trace Automation
Autonics Panels MP5W Data Trace Automation
Autonics Panels MP5W Data Trace Automation
Features
Sensors
(B)
3
types of operation mode are added. Shaded parts ( ) are changed and added Fiber
(total 16 types of operation mode) functions from previous MP5. Optic
Sensors
Frequency/Revolutions/Speed, Passing speed, Cycle, Passing time,
Time interval, Time differential , Absolute ratio, Error ratio, Density, (C)
Door/Area
Error, Length measurement 1, Length measurement 2, Interval, Sensors
MP5Y MP5W
(I)
Please read “Safety Considerations” in operation SSRs / Power
Controllers
manual before using.
(J)
Counters
Ordering Information
MP 5 Y - 4 N
(K)
Timers
(L)
Main output Sub output Panel
(comparative value output) (display value output) Meters
Output
S N Indicator - (M)
Tacho /
Speed / Pulse
N Indicator - Meters
S DIN W48×H48mm
Size
Y DIN W72×H36mm
W DIN W96×H48mm
Digits
5 99999 (5-digit)
Item
MP Pulse meter
M-7
MP5S/MP5Y/MP5W Series
Specifications
Series MP5S MP5Y MP5W
Display method 7-segment LED (zero blanking method)
Character size W4×H8mm W7×H14mm
Display range -19999 to 99999
Power AC voltage 100-240VACᜠ 50/60Hz
supply AC/DC voltage 24VACᜠ 50/60Hz, 24-48VDCᜡ
Max. 7.5VA Max. 9VA Max. 15VA
Power AC voltage
(100-240VACᜠ 50/60Hz) (100-240VACᜠ 50/60Hz) (100-240VACᜠ 50/60Hz)
consum-
ption Max. 6VA (24VACᜠ 50/60Hz), Max. 7VA (24VACᜠ 50/60Hz), Max. 11VA (24VACᜠ 50/60Hz),
AC/DC voltage
max. 4.5W (24-48VDCᜡ) max. 6.2W (24-48VDCᜡ) max. 7W (24-48VDCᜡ)
Permissible voltage range 90 to 110% of rated voltage
External power supply Max. 12VDCᜡ ±10% 80mA
Sub power supply - Max. 24VDCᜡ 30mA
·Solid state input 1: max. 50kHz (pulse width: min. 10㎲)
·Solid state input 2: max. 5kHz (pulse width: min. 100㎲)
Input frequency
※For F7, F8, F9, F10 operation mode, max. 1kHz (pulse width: min. 500㎲)
·Contact input: max. 45Hz (pulse width: min. 11ms)
[Voltage input] High: 4.5-24VDCᜡ, Low: 0-1VDC, Input impedance: 3.9kΩ
Input method [No-voltage input] Short-circuit impedance: Max. 80Ω, Residual voltage: Max. 1VDC,
Open-circuit impedance: Min. 100kΩ
·Operation mode F1, F2, F7, F8, F9, F10 : 0.0005Hz to 50kHz
·Operation mode F3, F4, F5, F6 : 0.01 to max. of each time range
Measurement range
·Operation mode F11, F12, F13, F16 : 0 to 99999
·Operation mode F14, F15 : -19999 to 99999
Measurement accuracy ·Operation mode F1, F2, F7, F8, F9, F10 : F.S.±0.05%rdg±1-digit
(23℃±5℃) ·Operation mode F3, F4, F5, F6 : F.S.±0.01%rdg±1-digit
Display cycle OFF (for F2, F16 operation mode), 0.05, 0.5, 1, 2, 4, 8 sec (same as update output cycle)
Frequency/Revolutions/Speed (F1), Passing speed (F2), Cycle (F3), Passing time (F4),
Time interval (F5), Time differential (F6), Absolute ratio (F7), Error ratio (F8), Density (F9), Error (F10),
Operation mode
Length measurement 1 (F11), Interval (F12), Accumulation (F13), Addition/Subtraction-individual input (F14),
Addition/Subtraction-phase difference input (F15), Length measurement 2 (F16)
Prescale function Direct input method (0.0001×10-9 to 9.9999×109)
※1
Hysteresis 0 to 9999
Relay triple 250VACᜠ 3A resistive load
Relay quintuple - 250VACᜠ 3A resistive load
Main
NPN/PNP open
Output
M-8
Pulse Meter
Connections (A)
Photoelectric
※Terminal connections differ by power supply and output type of each series and model. Sensors
(C)
Door/Area
Sensors
Brown
Black
Black
Blue
※1 (D)
INA INB +12V 0V HOLD/RESET Proximity
Sensors
6 7 8 9 10
(E)
Pressure
Sensors
24-48VDC 1 2 3 4 5 Boxes/Sockets
MP5S-2N
24VAC 50/60Hz (H)
Temperature
100-240VAC Controllers
MP5S-4N - + ※2
50/60Hz
SOURCE (I)
SSRs / Power
Controllers
MP5Y Series
(J)
Power/Input Terminal (Common) Counters
(L)
Panel
※1: O
peration mode F1 to F12 Meters
: display value HOLD
Operation mode F13 to F16 (M)
Tacho /
: display value RESET Speed / Pulse
Black Black Blue Brown Meters
※2: Model Source
1 2 3 4 5 6 7 MP5Y-2
24-48VDC (N)
24VAC 50/60Hz Display
Units
INA INB 0V +12V
100-240VAC
※1 MP5Y-4
HOLD/RESET 50/60Hz (O)
- + ※2
Sensor
SOURCE Controllers
(P)
Switching
Mode Power
Supplies
O
utput Connector (MP5Y- 1 to 5)
(Q)
※Hirose connector: HIF3BA-10PA-2.54DS Stepper Motors
※Hirose connector socket: HIF3BA-10D-2.54R (sold separately) & Drivers
& Controllers
※Hirose connector socket is not included. Contact a hirose connector dealer regarding sockets and cables.
(R)
Graphic/
Logic
Panels
● MP5Y- 1 (NPN open collector output) ● MP5Y- 2 (PNP open collector output)
(S)
MAIN OUT (NPN OPEN COLLECTOR) MAIN OUT (PNP OPEN COLLECTOR) Field
Network
30VDC 30mA 30VDC 30mA Devices
HH GO LL HH GO LL (T)
Software
2 4 6 8 10 2 4 6 8 10
1 3 5 7 9 1 3 5 7 9
COM H L COM H L
M-9
MP5S/MP5Y/MP5W Series
● MP5Y- 3 (BCD dynamic output) ● MP5Y- 4 (PV transmission output)
BCD OUT (NPN OPEN COLLECTOR)
30VDC 30mA DC4-20mA/DC0-20mA
A C D0 D2 D4 Load 500Ω Max. (+)
2 4 6 8 10 2 4 6 8 10
1 3 5 7 9 1 3 5 7 9
COM B D D1 D3
(-)
※Autonics display unit (DS/DA Series) is recommended
for stable minus (-) sign display.
2 4 6 8 10 8 9 10 11 12 13 14 15
1 3 5 7 9 H GO L
CONTACT OUT:
RS485 A(+) 250VAC 3A RESISTIVE LOAD
MP5W Series
●Power/Input Terminal (Common)
※MP5W- N (indicator) only has 'Power/Input terminals'.
10 11 12 13 14 15 10 11 12 13 14 15
HH H GO L LL COM
M-10
Pulse Meter
Output Connector (MP5W- 2/4/5/8/9) (A)
Photoelectric
※Hirose connector: HIF3BA-20PA-2.54DS Sensors
※Hirose connector socket: HIF3BA-20D-2.54R (sold separately)
※Hirose connector socket is not included. Contact a hirose connector dealer regarding sockets and cables. (B)
Fiber
※1: Sub power supply Optic
Sensors
※2: POL signal turns ON when the display value is a minus (-) value.
● MP5W- 2 (NPN open collector+BCD dynamic output) (C)
Door/Area
Sensors
MAIN OUT (NPN OPEN COLLECTOR)
30VDC 30mA +24VDC (D)
※
30mA Max. 1 Proximity
HH GO LL B D D1 D3 DOT COM2
Sensors
2 4 6 8 10 12 14 16 18 20 (E)
Pressure
Sensors
1 3 5 7 9 11 13 15 17 19 (F)
Rotary
Encoders
※2
COM H L A C D0 D2 D4 POL
(G)
0V BCD OUT (NPN OPEN COLLECTOR) Connectors/
Connector Cables/
30VDC 30mA Sensor Distribution
Boxes/Sockets
※Autonics display unit (DS/DA Series) is recommended for stable minus (-) sign display.
(H)
Temperature
Controllers
● MP5W- 4 ● MP5W- 5
(NPN open collector+PV transmission output) (PNP open collector+PV transmission output) (I)
SSRs / Power
Controllers
MAIN OUT (PNP OPEN COLLECTOR)
MAIN OUT (NPN OPEN COLLECTOR)
30VDC 30mA
30VDC 30mA
+24VDC (J)
Counters
※
30mA Max. 1 (+) HH GO LL
HH GO LL
2 4 6 (K)
2 4 6 8 10 12 14 16 18 20 Timers
1 3 5 (L)
9 11 13 15 17 19
Panel
1 3 5 7 COM H L
Meters
COM H L (M)
Tacho /
0V (-) Speed / Pulse
DC4-20mA/DC0-20mA Meters
MAIN OUT (NPN OPEN COLLECTOR) MAIN OUT (PNP OPEN COLLECTOR)
(P)
30VDC 30mA 30VDC 30mA Switching
Mode Power
+24VDC RS485 Supplies
※
30mA Max. 1 B(-) HH GO LL
HH GO LL (Q)
Stepper Motors
2 4 6 & Drivers
2 4 6 8 10 12 14 16 18 20 & Controllers
(R)
Graphic/
1 3 5 Logic
1 3 5 7 9 11 13 15 17 19 Panels
COM H L (S)
Field
COM H L Network
0V A(+) Devices
RS485
(T)
Software
M-11
MP5S/MP5Y/MP5W Series
Dimensions (unit: mm)
※Nameplate design is changed from the previous MP5.
※Side dimensions of MP5Y/W differ by output type.
●MP5S Series
48 10 90
45
●MP5Y Series MP5Y- 1/2/3/4/5 MP5Y- 6
72 6 89.5 14.5 15.3
30
36
10.5 10.5
※M
P5Y- N (indicator) does not include the shaded part
(output hirose connector or output terminal).
45
48
10.5 10.5
※MP5W- N (indicator) does not include the shaded part
(output hirose connector or output terminal).
Panel cut-out dimensions
A
(unit: mm)
D Size
A B C D
Series
B MP5S Min. 55 Min. 62 45.5 +0.5
45.5 +0.5
C
0 0
Bracket
For MP5S For MP5Y/W
41
4.2
3.9
73
30
12±0.2
10
6
45.4
50
61
4.5
0.82
4
9.5
1
15
0.2±0.2
M3
42.2
12.2 45.4
16.4 47.8
48.6 61.64
M-12
Pulse Meter
Unit Description (A)
Photoelectric
●MP5S Series ●MP5Y Series ●MP5W Series Sensors
4
4 (B)
Fiber
Optic
Sensors
1 1 1
(C)
Door/Area
Sensors
(D)
Proximity
Sensors
2 3 2 3
1: Display component (E)
2 3
Displays current value in RUN mode. Pressure
Sensors
Alternately displays setting parameters and corresponding value in SETTING mode.
2: key
In RUN mode, press the key once to check max./min. value. (F)
Rotary
In RUN mode, hold the key for over 2 sec to enter parameter groups. Encoders
3: , , key
Select parameter groups, and select or setting values in the corresponding parameters. (G)
Connectors/
4: O utput status indicator Connector Cables/
Sensor Distribution
Boxes/Sockets
Sold Separately (H)
Communication converter Temperature
Controllers
(J)
Counters
(K)
Timers
(L)
Panel
Meters
(N)
Display
Units
Input frequency: Max. 50kHz (ON/OFF pulse width: min. 10㎲ of each) OFF (R)
(2) S
olid state input 2 Pulse width Graphic/
Input frequency: Max. 5kHz (ON/OFF pulse width: min. 100㎲ of each) ON OFF Logic
Panels
※For F7, F8, F9, F10 operation mode, max. 1kHz (ON/OFF pulse width: min. 500㎲ of each)
(3) Contact input T (S)
Field
① Input frequency: Max. 45Hz (when each ON/OFF pulse width is over 11ms) ※T: s ingle cycle of input signal
Network
Devices
② Contact specifications: 12VDC, stable switching of load current as small as 5mA
2. Input type [IN-A, IN-B]
(T)
MP5 allows selection between NPN input (solid state/contact) or PNP input (solid state/contact). Software
(1) NPN input type (2) PNP input type
①Contact ②NPN voltage ③NPN open collector ①Contact ②PNP voltage ③PNP open collector
output type sensor output type sensor MP5 output type sensor output type sensor MP5
+12V +12V
Sensor circuit
Sensor circuit
Sensor circuit
Sensor circuit
Sensor circuit
Sensor circuit
3.9kΩ
IN
IN
0V 0V
(COM) 3.9kΩ
(COM)
M-13
MP5S/MP5Y/MP5W Series
Output Specifications
1. Relay output
① Output: Comparative or alarm output (refer to " Output Modes")
② Output type: Relay
③ Contact capacity: 250VAC 3A resistive load
④ Life cycle: [Mechanical] min. 10,000,000 operations (switching frequency 180 operations/min)
[Electrical] min. 100,000 operations (3A 250VAC, 30VDC resistive load) (switching frequency 20 operations/min)
2. Transistor output
① Output: Comparative output or alarm output (refer to " Output Modes")
② Output type: NPN/PNP open collector
③ Rated load voltage: 30VDC
④ Max. load current: 30mA
3. BCD dynamic output (negative logic) E.g.) To display value = 125.89 by BCD dynamic output
① Output: present value 104-digit 100-digit
② Output signal: BCD data (A, B, C, D, DOT)
← A: lowest bit, DOT: highest bit PV display value 1 2 5. 8 9
Digit data (D0, D1, D2, D3, D4)
A
← D0: lowest digit, D4: highest digit
③ Output type: NPN open collector B
④ Rated load voltage: 30VDC BCD
⑤ Max. load current: 30mA Data C
⑥ Dynamic COM cycle (T) = 40ms
D
DOT
D0
D1 0.1ms
D2
Digit
D3
D4
5ms 8ms
40ms
4. PV transmission output
① Application: transmit measured value
② Function: transmit measured value within setting range of high-limit output [FS-H] to low-limit output [FS-L] after conversion into
DC4-20mA or DC0-20mA current.
③O utput range of high/low-limit
·High-limit [FS-H] range: From min. value to max. value within measurement range
·Low-limit [FS-L] range: From min. value to max. value within measurement range ([FS-H]≥[FS-L]+1)
(1) DC4-20mA transmission output (2) DC0-20mA transmission output
① Transmit measured value within setting range of high-limit ① Transmit measured value within setting range of high-limit
output [FS-H] to low-limit output [FS-L] after conversion output [FS-H] to low-limit output [FS-L] after conversion into
into DC4-20mA current. DC0-20mA current.
② Resistive load: Max. 500Ω ② Resistive load: Max. 500Ω
③ Resolution: 8000 divisions ③ Resolution: 10,000 divisions
Diplay value Display value
FS-H FS-H
FS-L FS-L
Set [FS-L] and [FS-H] and Set [FS-L] and [FS-H] and
the output is DC4-20mA. 20mA the output is DC0-20mA. 20mA
If the setting width between [FS-L] and If the setting width between [FS-L] and
[FS-H] is lower than 8000 divisions, the 4mA [FS-H] is lower than 10,000 divisions, 0mA
resolution is also reduced. the resolution is also reduced.
M-14
Pulse Meter
Parameter Groups (A)
Photoelectric
Sensors
(B)
Parameter 0 group
(max./min. monitoring value)
RUN HOLD/RESET
※
Fiber
Optic
mode
Sensors
● Parameter 0 group
(I)
SSRs / Power
Controllers
RUN mode
(J)
Counters
Flashes
※1
alternately HH comparative value (K)
PStHH 99999 ※Does not appear Timers
in F output mode
※The parameters are identical to [PStHH], (L)
[PSt H], [PSt L], [PStLL] of parameter 2 Panel
Meters
group and the setting values will be linked.
●Setting range by operation mode
PSt H 99999 H comparative value (M)
Tacho /
Operation mode Setting range Speed / Pulse
F1, F2, F7, F9, F11, Meters
0 to 99999
F12, F13, F16
(N)
F3, F4, F5, F6 0 to setting time range Display
Units
PSt L 00000 L comparative value F8, F10, F14, F15 `9999 to 99999
(the setting range varies depending on the (O)
Sensor
decimal point setting.) Controllers
※Only appears in comparative value setting
LL comparative value models. (P)
(T)
Software
M-15
MP5S/MP5Y/MP5W Series
● Parameter 1 group
2 sec
RUN mode PARa1 PARa2 PARa3
3 sec
Flashes
※
alternately 1 Operation mode
MODE F
ㄹ 1 ●Setting range: F1 to F16
●Setting range
IN-A NPnhF Sensor type of input A Parameter Input sensor type
NPnhF NPN solid state input 1
NPnmF NPN solid state input 2
NPnlF NPN contact input
PNphF PNP solid state input 1
PNpmF PNP solid state input 2
IN-B NPnhF Sensor type of input B PNplF PNP contact input
●Setting range
Parameter Output mode Parameter Output mode
OUT-T STARD Output mode STARD S (Standard) OUT-B B (Block)
OUT-H H (High) OUT-I I (One-shot)
OUT-L L (Low) OUT-F F (Deflection)
STArT 9(9
Start compensation timer function &
compensation time
●Setting range: )0 to 9(9 (sec)
●Setting range:
)1 to 999(9 (sec)
Memory retention
MEMO OFF ●Setting range: ㅒㅜON, OFF
M-16
Pulse Meter
● Parameter 2 group (A)
Photoelectric
2 sec Sensors
RUN mode PARa1 PARa2 PARa3
(B)
Fiber
3 sec Optic
Sensors
Flashes
(C)
※
alternately 1 Data bank Door/Area
pBANK 1 ●Setting range: 1, 2 Sensors
※Only appears in MP5W.
(D)
Proximity
Sensors
HH comparative value
PStHH 99999 ※Does not appear ※The parameters are identical to [PStHH],
(I)
SSRs / Power
Controllers
in F output mode [PSt H], [PSt L], [PStLL] of parameter 0
group and the setting values will be linked.
●Setting range by operation mode (J)
Counters
PSt H 99999 H comparative value Operation mode Setting range
F1, F2, F7, F9, F11,
0 to 99999
F12, F13, F16 (K)
Timers
F3, F4, F5, F6 0 to set time range
F8, F10, F14, F15 `9999 to 99999
PSt L 00000 L comparative value (the setting range varies depending on (L)
Panel
the decimal point setting.) Meters
(P)
Switching
Mode Power
Prescale exponent (y) of input A Supplies
PScaY 10 01 ●Setting range: 10 - 9 (10-9) to 10 09 (109) (Q)
Stepper Motors
& Drivers
& Controllers
(S)
Field
Network
Prescale exponent (y) of input B Devices
PScbY 10 01 ●Setting range: 10 - 9 (10-9) to 10 09 (109)
(T)
Software
M-17
MP5S/MP5Y/MP5W Series
● Parameter 3 group
2 sec
RUN mode PARa1 PARa2 PARa3
3 sec
Flashes
※
alternately 1
High-limit value of PV ●Setting range by operation mode
FS-H 99999 transmission output Operation mode Setting range
F1, F2, F7, F9, F11, F12,
0 to 99999
F13, F16
F3, F4, F5, F6 0 to set time range
F8, F10, F14, F15 `9999 to 99999
Low-limit value of PV trans-
FS-L 00000 mission output
(the setting range varies depending on the
decimal point setting.)
※Only appears in PV transmission output
models.
Current output
MA 4-20 specifications
●Setting range: 4-20, 0-20
Communication address
ADDR 01 ●Setting range: 01 to 99
Communication speed
B
ㅜㅠ PS 9600 ●Setting range: 9600, 19200,
38400, 2400, 4800 (bps)
Communication write
COmW D
ㅇ ISA ●Setting range: ENA (enable), DISA (disable)
Lock
●Setting range
LOC OFF
Parameter Function
OFF Unlock
LOc0 Lock all
LOc1 Parameter 1/2/3 lock
LOc2 Parameter 2/3 lock
LOc3 Parameter 3 lock
M-18
Pulse Meter
Operation Mode by Parameter Groups ( : parameter display, X: no parameter display) (A)
Photoelectric
Sensors
Operation
mode F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16
Parameter (B)
Fiber
※1 Optic
PStHH Sensors
※2
PSt H
(C)
※2 Appears in all operation modes (F1 to F16). Door/Area
0 group
PSt L Sensors
※1
PSt LL
(D)
hPEK Proximity
Sensors
lPEK
(E)
MODE Pressure
Appears in all operation mode (F1 to F16). Sensors
IN-A
※3
IN-B (F)
※2 Rotary
※4
Encoders
OUT-T
1 group
※2
(G)
HYS Connectors/
※2 Connector Cables/
GVARD Sensor Distribution
Boxes/Sockets
AVToA
(H)
Temperature
AVToB Controllers
MEMO
(I)
pBANK ※Only appears in MP5W. Appears in all operation modes (F1 to F16). SSRs / Power
Controllers
DOT
(J)
tUNT Counters
※1
PStHH
※2
PSt H (K)
Timers
※2
PStLL Appears in all operation modes (F1 to F16).
2 group
※1
PSt L (L)
Panel
Meters
PScaH
PScaY (M)
Tacho /
Speed / Pulse
PScbH Meters
PScbY (N)
※5 Display
DISpT Units
COUnB
(O)
Sensor
FS-H Controllers
※Only appears in PV transmission output models.
FS-L
Appears in operation modes (F1 to F16). (P)
Switching
ㅡMA Mode Power
Supplies
ADDR
(Q)
3 group
Stepper Motors
BPS & Drivers
& Controllers
PRTY ※Only appears in RS485 comm. output models.
Appears in all operation modes (F1 to F16). (R)
STP Graphic/
Logic
Panels
REwT
(S)
COmW Field
Network
LOC Devices
M-19
MP5S/MP5Y/MP5W Series
Operation Modes [MODE]
Select operation mode from operation mode[MODE]of parameter 1 group..
MP5 has 16 operation modes.
F1 Mode: Frequency/Revolutions/Speed
Measures the frequency of input A and displays the calculated frequency, revolutions, and speed.
Hz 1 Timing chart
Frequency
kHz 0.001
rps 1 Input A
Revolutions
rpm (default) 60 t1 t2 t3 t4 t5 t6
Hold
mm/sec 1,000L input
cm/sec 100L 1 α 1 α 1 α 1 α 1 α
Display t1 t2 t3 t5 t6
Speed m/sec 1L
m/min 60L
km/hour 3.6L
M-20
Pulse Meter
F4 Mode: Passing Time (A)
Measures the time from Input A ON to the next ON, and displays the passing time of the arbitrary distance. Photoelectric
Sensors
Passing time[sec]= t × α
(B)
L[m]
(α= ) Fiber
Distance advanced in 1 pulse cycle [m] Optic
Sensors
SEC MIN
(E)
999.99s Timing chart Pressure
999.99m Sensors
(default)
Input A
Passing time 9999.9s 9999.9m (F)
t1 t2 t3 t4 t5 t6 Rotary
99m59.9s 99h59.9m Hold Encoders
input (G)
9h59m59s 999h59m Connectors/
Display t1 α t2 α t3 α t5 α t6 α Connector Cables/
99999s 99999m Sensor Distribution
Boxes/Sockets
(H)
Temperature
Controllers
(I)
F5 Mode: Time Interval SSRs / Power
Controllers
Displays measured time of Input A ON
Time interval (T) = t
MP5 (J)
※t: measured time of input A ON [sec] Counters
Motor
Display value and display unit ([tUNT] of parameter 2)
Stamp (K)
Display value Display unit Timers
SEC MIN
Timing chart (L)
Panel
999.99s
999.99m Input A
Meters
(default)
(M)
Time interval 9999.9s 9999.9m t1 ta t2 ta t3 Tacho /
Hold Speed / Pulse
99m59.9s 99h59.9m input
Meters
M-21
MP5S/MP5Y/MP5W Series
F7 Mode: Absolute Ratio
Measures and displays relative speed, amount, speed, etc.
of input B against input A in percentage (%).
Flow meter A Flow meter B
Absolute ratio = (Input B / Input A) × 100%
Frequency of input B[Hz] × Bα
Absolute ratio = × 100[%]
Frequency of input A[Hz] × Aα MP5
Liquid
※Aα: Prescale value of input A, Bα: Prescale value of input B
Timing chart
Display value and display unit
Input A
Display value Display unit
fA
Absolute ratio % Input B
fB
※Hold: When the hold signal turns ON, the display value is Frequency of input B[Hz] × Bα
maintained until the display cycle turns to hold OFF. Display = × 100[%]
Frequency of input A[Hz] × Aα
F9 Mode: Density
Measures and displays the density ratio (%) of input B against the total sum of input A
and input B.
Input B
Density = × 100[%] Flow meter A Flow meter B
Input A + Input B
Frequency of Input B[Hz] × Bα
Density = × 100[%]
(Frequency of input A[Hz] × Aα) + (Frequency of input B[Hz] × Bα)
Liquid
※Aα: Prescale value of input A, Bα: Prescale value of input B MP5
※Hold: When the hold signal turns ON, the display value is Input B
maintained until the display cycle turns to hold OFF. fB
M-22
Pulse Meter
F11 Mode: Length Measurement 1 (A)
Measure and display the number of input A pulses during input B ON. Photoelectric
Sensors
Length measurement = P × α Input A
Input B (B)
※P: Number of input A pulses, α: Prescale value Fiber
Optic
Photoelectric sensor Sensors
Interval = P × α (H)
※P: Number of input A pulses, α: Prescale value Temperature
Controllers
(M)
Tacho /
Speed / Pulse
F13 Mode: Accumulation Meters
Measures and displays the counted value of input A pulses.
(N)
Accumulation = P × α Display
be re-counted. Display 0 1 2 3 4 5 6 0 1 2 3 4
(R)
③When RESET input is ON, the integrated counted value will be reset Graphic/
to "0". ※α=1 display value Logic
Panels
(S)
Field
Network
Devices
(T)
Software
M-23
MP5S/MP5Y/MP5W Series
F14 Mode: Addition/Subtraction-Individual Input
Displays the counted value from added input A pulses and subtracted MP5
input B pulses. When there are two inputs simultaneously, it will not count.
Addition/Subtraction = Input A × α - Input B × β
※α: Prescale value of input A, β: Prescale value of input B Photoelectric Input B
sensor Input A (subtraction)
(addition)
Timing chart
Display value and display unit
H
Display value Display unit Input A L
Addition/ H
Input B
Subtraction Quantity L
(individual input) RESET H
L
Operation and timing chart
Display 0 1 2 32 0 1 2 3 2 1
Pulse of input A is added, and pulse of input B is subtracted.
※α, β=1 display value
M-24
Pulse Meter
Output Modes [OUT-T] (A)
Photoelectric
MP5 Series supports 6 output modes. (There is no output mode in indicator models). Sensors
Requirement for setting comparative value: (B output mode) LL<L<H<HH, (F output mode) L<H,
(other output modes) individual output operation regardless of size or order of set comparative values. ※1: hysteresis (B)
Fiber
S (standard) Output Mode [STARD] H (high) Output Mode [OVT-H] Optic
Sensors
HH HH
Comparative H Comparative H (C)
L Door/Area
value L value Sensors
LL LL
※1 ※1
HH HH (D)
※1 ※1 Proximity
H H Sensors
L ※1
Output GO Output
※1 LL ※1
L (E)
Pressure
LL
※1 GO Sensors
HH output : Display value ≥ Comparative setting value HH HH output : Display value ≥ Comparative setting value HH (F)
Rotary
H output : Display value ≥ Comparative setting value H H output : Display value ≥ Comparative setting value H Encoders
L output : Display value ≤ Comparative setting value L L output : Display value ≥ Comparative setting value L
(G)
LL output : Display value ≤ Comparative setting value LL LL output : Display value ≥ Comparative setting value LL Connectors/
※GO output ON when there are no HH, H, L, LL outputs ※GO output ON when there are no HH, H, L, LL outputs Connector Cables/
Sensor Distribution
Boxes/Sockets
(H)
L (low) Output Mode [OUT-L] B (block) Output Mode [OUT-B] Temperature
Controllers
HH
Comparative H HH
Comparative H (I)
value L SSRs / Power
LL value L Controllers
LL
HH ※1 ※1
※1
HH ※1 (J)
H H Counters
L ※1
Output Output GO
※1 L ※1
LL
(K)
GO LL ※1 Timers
HH output : Display value ≤ Comparative setting value HH HH output : Display value ≥ Comparative setting value HH
H output : Display value ≤ Comparative setting value H H output : Comparative setting value HH > Display value ≥ (L)
Panel
L output : Display value ≤ Comparative setting value L Comparative setting value H Meters
LL output : Display value ≤ Comparative setting value LL L output : Comparative setting value LL < Display value ≤
(M)
※GO output ON when there are no HH, H, L, LL outputs Comparative setting value L Tacho /
LL output : Display value ≤ Comparative setting value LL Speed / Pulse
Meters
※GO output ON when there are no HH, H, L, LL outputs
(N)
I (one-shot) Output Mode [OUT-I] F (deflection) Output Mode [OVT-F] Display
Units
Transmits outputs when the saved setting value exceeds H
HH deviation or L deviation.
(O)
Comparative H Saving setting value: press the + keys to save as setting value. Sensor
value L Checking setting value: press the key to check the setting value. Controllers
LL 0.3s Setting deviation: Sets H deviation [PSt H], and L deviation[PSt
(P)
HH L] of parameter group 0,2 with the setting value as reference. (The Switching
0.3s
set deviation value is saved during Power OFF until it is re-set.) Mode Power
H Supplies
Ouput GO Deviation setting range: 0.0001 to 99999 (the setting range varies
0.3s depending on the decimal point [DOT] setting.) (Q)
Stepper Motors
L E.g.)Decimal point[DOT]: 0000.0, Setting range: 0.1 to 9999.9 & Drivers
0.3s & Controllers
LL Saving setting value ( + key)
(high-limit) (R)
H deviation Graphic/
Logic
Setting value Panels
HH output : Display value ≥ Comparative setting value HH (low-limit)
H output : Comparative setting value HH > Display value ≥ L deviation (S)
Field
Comparative setting value H ON Network
Power OFF Devices
L output : Comparative setting value H > Display value ≥
Saving ON
Comparative setting value L setting value OFF
LL output : Comparative setting value L > Display value ≥ L deviation ON ※2 (T)
Software
Comparative setting value LL output OFF
※3
※No GO output H deviation ON
output OFF
※One-shot output time is fixed at 0.3 sec.
※No hysteresis ※2: W hen selecting initial comparative output limit function, it does
not transmit outputs.
※3: The graph is assuming that there is a saved setting value prior
to the setting value save point. The actual output position may
be different.
※There are no HH, GO, LL outputs.
※The deviation can be set to "0" but the actual operation will be the
same as "1".
M-25
MP5S/MP5Y/MP5W Series
Function Comparative setting
Hysteresis [HYS] value H, HH
Near the comparative setting value, the output may turn ON/OFF
frequently and unstably. Comparative setting
To prevent this, hysteresis value is set based on the comparative value L, LL A
A
setting value.
Output H, HH
※A: hysteresis value
※The hysteresis value can be set to "0" but the actual operation value is "1". Output L, LL
HH HH
H H
Output GO Output GO
L L
LL LL
Comparative output limit function Comparative output limit function
removal removal
※After supplying power, there is no initial L, LL comparative outputs ( ).
※Each setting value of HH, H, LL, L is not related to their relative sizes. Hence, HH value may be lower or equal to LL value.
M-26
Pulse Meter
RS485 Communication Output (A)
Photoelectric
pplicable for models with RS485 communication output through sub output (MP5Y- 5, MP5W- 8/9).
A Sensors
Please refer to ' Ordering Information'.
1. Communication specifications (B)
Fiber
Optic
Comm. protocol Modbus RTU 2400, 4800, 9600 (default), 19200, Sensors
Communication Speed
Connection type RS485 38400 bps
Application standard Compliance with EIA RS485 Communication response time 5 to 99ms (default: 20ms) (C)
Door/Area
Max. connection 31 units (address: 01 to 99) Start Bit 1-bit fixed Sensors
(I)
A(+) SSRs / Power
Controllers
※It is recommended to use Autonics communication converter; SCM-WF48 (Wi-Fi to RS485·USB wireless communication converter, sold
separately), SCM-US48I (USB to RS485 converter, sold separately), SCM-38I (RS232C to RS485 converter, sold separately).
(J)
Please use twisted pair wire for RS485 communication. Counters
3. Communication control sequence
1. Communication equence follows Modbus RTU protocol.
2. Communication with the host system can be established after 1sec (1,000ms) of supplying power. (K)
Timers
3. The initial transmission authority is held by the host device (PC). When the host device transmits a request, the MP5W/Y Series sends a
response.
Read command
Read command
(L)
No. of data
No. of data
Address
Address
Address
Address
Panel
CRC16
CRC16
Meters
Host
system (M)
Tacho /
Speed / Pulse
※A: a
fter 1 sec of supplying
Response command
Meters
No. of data
Address
power
CRC16
MP5W/Y B: 38400bps:
approx. 1.75ms (N)
CRC16
5-2. Read Holding registers (func. 03 H), read input registers (func. 04 H)
1) Query (Master)
Function Starting Address No. of Points (no. of data) Error Check (CRC 16)
Slave Address
(command) High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
CRC16
M-27
MP5S/MP5Y/MP5W Series
2) Response (Slave)
Function Byte Count Data Data Data Error Check (CRC 16)
Slave Address
(command) (no. of data byte) High Low High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
CRC16
2) Response (Slave)
Function Coil Address Force Data Error Check (CRC 16)
Slave Address
(command) High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
CRC16
CRC16
CRC16
2) Response (Slave)
Function Starting Address No. of Register Error Check (CRC 16)
Slave Address
(command) High Low High Low Low High
1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte 1Byte
CRC16
CRC16
hen a communication error occurs, the highest bit from the received command (function) is set (1), a response command is sent, and the
W
corresponding exception code is transmitted.
(1) ILLEGAL FUNCTION (exception code: 01 H)
: Unsupported command
(2) ILLEGAL DATA ADDRESS (exception code: 02 H)
: The requested start address does not not match the transmission address of the device.
(3) ILLEGAL DATA VALUE (exception code: 03 H)
: The number of requested data does not match the transmission number of the device.
(4) S LAVE DEVICE FAILURE (exception code: 04 H)
: The requested command cannot be processed properly. (CRC)
M-28
Pulse Meter
6. Address mapping table (A)
6-1. Read coil status (func. 01) / Force single coil (func. 05) Photoelectric
Sensors
No.(Address) Func R/W Parameter Description Setting range Note
000001(0000) 01 R/W HH HH comparative output 0: OFF / 1: ON (B)
Fiber
000002(0001) 01 R/W H H comparative output Comparative 0: OFF / 1: ON Optic
Sensors
000003(0002) 01 R/W GO GO comparative output output 0: OFF / 1: ON
000004(0003) 01 R/W L L comparative output LED 0: OFF / 1: ON
(C)
000005(0004) 01 R/W LL LL comparative output 0: OFF / 1: ON Door/Area
Sensors
000006(0005) 01 R/W 0: OFF / 1: ON
000007(0006) 01 R/W 0: OFF / 1: ON
(D)
000008 to 000050 01 R/W 0: OFF / 1: ON Proximity
Sensors
6-2. Read input status (func. 02)
No.(Address) Func R/W Parameter Description Setting range Note
(E)
100001(0000) 02 R RESET(HOLD) External input RESET input status Pressure
variables Sensors
100002(0001) 02 R BANK BANK input status
100003(0002) 02 R 0: OFF / 1: ON
100004(0003) 02 R 0: OFF / 1: ON (F)
Rotary
100005(0004) 02 R 0: OFF / 1: ON Encoders
100006(0005) 02 R 0: OFF / 1: ON
(G)
100007(0008) 02 R 0: OFF / 1: ON Connectors/
Connector Cables/
100008(0007) 02 R 0: OFF / 1: ON Sensor Distribution
100009(0008) 02 R 0: OFF / 1: ON Boxes/Sockets
100010(0009) 02 R 0: OFF / 1: ON (H)
100011(000A) 02 R 0: OFF / 1: ON Temperature
Controllers
100012 to 100050 02 R 0: OFF / 1: ON
M-29
MP5S/MP5Y/MP5W Series
6-4. R
ead holding registers (func. 03) / Preset single register (func. 06) /
Preset multiple registers (func. 16)
6-4-1. Comparative value settings and peak value check group
Factory
No.(Address) Func R/W Parameter Description Setting range
default
400001(0000) HH comparative
03/16 R/W PStHH Preset HH 0 to 99999 99999
400002(0001) value
400003(0002)
03/16 R/W PSt H Preset H H comparative value 0 to 99999 99999
400004(0003)
400005(0004) ※1
03/16 R/W PSt L Preset L L comparative value 0 to 99999 00000
400006(0005)
400007(0006) ※1
03/16 R/W PStLL Preset LL LL comparative value 0 to 99999 00000
400008(0007)
400009(0008) High peak value ※2
03/16 R/W hPEK High Peak 99999 -
400010(0009) of measured value
400011(000A) Low peak value ※2
03/16 R/W lPEK Low Peak -19999 -
400012(000B) of measured value
400013 to 400050 03/06/16 R/W Reserved
※1: In operation modes F8, F10, F14, F15,the setting range is -19999 to 99999
※2: Max./Min. measurement value
6-4-2. Parameter 1 group
Factory
No.(Address) Func R/W Parameter Description Setting range
default
0: F1 to
400051(0032) 03/06/16 R/W MODE Mode Input operation mode 1: F2 14: F15 0
2: F3 15: F16
400052(0033) 03/06/16 R/W IN-A Input A 0: NPnhF
1: NPnmF
2: NPnlF
Sensor type 0
400053(0034) 03/06/16 R/W IN-B Input B 3: PNphF
4: PNpmF
5: PNplF
0: STARD
1: OUT-H
2: OUT-L
400054(0035) 03/06/16 R/W OUT-T Output type Output mode 0
3: OUT-B
4: OUT-I
5: OUT-F
400055(0036) 03/06/16 R/W HYS Hysteresis Hysteresis value 1 to 9999 1
0: fDEFY
400056(0037) 03/06/16 R/W GUArD Output limit Output limit function 0
1: STArT
Start compensation
400057(0038) 03/06/16 R/W STArT Start limit value 0.0 to 99.9 0.0
timer value
400058(0039) 03/16 R/W
AUToA Auto-zero A
400059(003A) 03/16 R/W
Auto-zero time 0.1 to 9999.9 9999.9
400060(003B) 03/16 R/W
AUToB Auto-zero B
400061(003C) 03/16 R/W
0: OFF
400062(003D) 03/06/16 R/W MEMO Memory Memory retention 0
1: ON
400063 to 400100 03/06/16 R/W Reserved
6-4-3. Parameter 2 group
Factory
No.(Address) Func R/W Parameter Description Setting range
default
0: 1
400101(0064) 03/06/16 R/W pBANK Data bank Data bank 0
1: 2
0: 00000
1: 000)0
400102(0065) 03/06/16 R/W DOT Dot Decimal point 2: 00)00 0
3: 0)000
4: )0000
0: tSEC
400103(0066) 03/06/16 R/W tUNT Time unit Time unit 0
1: tMIN
0: 99(99 999.99s
1: 999(9 9999.9s
2: 9(5(9 99m59.9s
3: (5(59 9h59m59s
4: 99999 99999s
400104(0067) 03/06/16 R/W tSEC Time sec Time range 0
5: 99(99 999.99m
6: 999(9 9999.9m
7: 9(5(9 99h59.9m
8: 99(59 999h59m
9: 99999 99999m
M-30
Pulse Meter
6-4-3. Parameter 2 group
(A)
Factory Photoelectric
No.(Address) Func. R/W Parameter Description Setting range Sensors
default
400105(0068) 03/16 R/W HH (B)
PStHH Preset HH comparative 0 to 99999 99999 Fiber
400106(0069) 03/16 R/W value
Optic
Sensors
M-31
MP5S/MP5Y/MP5W Series
Comprehensive Device Management Program (DAQMaster)
●●DAQMaster is comprehensive device management program for convenient management of parameters and multiple
device data monitoring.
●●Visit our website (www.autonics.com) to download user manual and comprehensive device management program.
< Computer specification for using software > < DAQMaster screen >
Item Minimum requirements
System IBM PC compatible computer with Intel Pentium Ⅲ or above
Operations Microsoft Windows 98/NT/XP/Vista/7/8/10
Memory 256MB+
Hard disk 1GB+ of available hard disk space
VGA Resolution: 1024×768 or higher
Others RS-232 serial port (9-pin), USB port
M-32