392

MODEL

Circular Chart Recorder


Specification Sheet
● 1 to 4 Universal Input The 392 from Eurotherm® is a user configurable 1, 2, 3 or 4 pens, 100mm
Channels calibrated width circular chart instruments, utilising high visibility vacuum
fluorescent display. The modular construction and the use of surface
● 40 Character Vacuum mount technology assure a compact design, which is easy to maintain, and
fluorescent digital upgrade.
display
Configuration
● User Configurable
Use of the integral keypad, and the structured parameter list allows for fast
● Maths Functions basic set-up and selection of those functions needed for a particular
application. Configuration parameters are separated by a user definable
● Custom Curve password.
● 4 Totalisers with 9-
digit readout Display
The measured value for each channel is displayed along with, the channel
● Up to 2 Single or Dual number, engineering units, channel Descriptor (16 characters max) and
Output Controllers alarm information.
● Retransmission
Maths
Addition of the maths function allows for calculations ranging from simple
add, subtract through to the more complex, Mass flow and Relative
humidity.

Custom Curve
This features allows for a user defined input, such as a Pirani Vacuum Gauge
to be entered and selected for tracing on the recorder.

Totalisers
The 392 can be provided with up to 4 integrating/totalising channels, with
nine-digit resolution, for flow and power applications. Each totaliser channel
is capable of driving a relay output, for example to drive an
electromechanical counter.

Alarms
Up to four alarms can be configured per channel. Each alarm can be
configured as absolute low/high, deviation, or rate of change.

Relays Outputs
Up to 8 relay outputs can be fitted, driven by any internal recorder event
such as channel alarm, totaliser overflow, totaliser output.

Integral Controllers
The model 392 offers two PID controllers with features such as cascade,
ratio/bias, feedforward and internal setpoint generation. Dedicated
auto/manual and remote/local setpoint keypads allow the user to switch
between one control function to the other.

•EUROTHERM FLEXIBLE SOLUTIONS•


SPECIFICATION
Input Board Physical
Bezel size: 360mm H x 380mm (when viewed
General from the front, offset 5mm right with
Number of inputs: 1, 2, 3 or 4 respect to cut-out centre line)
Input Types: dc Volts, milli-volts, Dc milli-amps (with Panel cut-out dimensions: 340.5 H x 345mm W (both -0 +1 mm)
shunt) Thermocouple, 2/3 wire RTD Depth behind bezel rear face: 150mm
T/C Types: B, C, E, J, K, L, N, R, S, T, Ni/NiMo Weight: 7kg (typical)
RTD Types: Pt100A, Pt100D, Cu10, Ni100, Ni120 Panel Mounting: +5 to -30 degrees from vertical
Others: Linear, Square root, X3/2, X5/2, log (+ = top over hang)
User-entered.
Input Type mix: 4 Printing System
Input ranges: See Table 1 Pen Type: Disposable Fibre-tipped pens giving
Termination: Terminal Block approx. 500 metres of trace each
Chart type: Circular
Hardware Range Input Accuracy Minimum Span Chart speeds: 1 to 4096 hours / revolution.
4.0 to 20mV 0.02mV 4mV
12 to 60mV 0.06mV 15mV Memory Protection
16 to 80mV 0.08mV 20mV Configuration: saved in EEPROM
Active values (e.g. totalisers): Super cap back up for 100hrs
40 to 200mV 0.20mV 50mV
80 to 400mV 0.40mV 100mV
0.34 to 1.7 V 1.7mV 425mV
0.50 to 2.5 V 2.5mV 625mV Options
1.00 to 5.0 V 5mV 1.25V Maths Pack
Table 1 Number of Derived Variables: 2
Functions: See table 2
Shunt/Attenuator: Internally mounted resistor modules
Additional error due to shunt: 0.1% of input Off High Peak (highest Mass Flow (Linear)
Additional error due to attenuator: 0.2% of input value since reset)
Add (A+B) Low Peak (Lowest F0 (Sterilization Constant)
value since reset)
Recorder Subtract (A-B) Log (Log to base 10) Relative Humidity
Performance Multiply (A x B) Power (Power of 10) Zirconia Probe
Input resolution: 0.01% of operating gain span Divide (A / B) Mass Flow (Square root)
Pen position resolution: 1% of chart range Linear Polynomial
Display accuracy: ±(0.05% of operating gain span (A x B + C) (B + C x A + D x A2 + E x A3)
+ 0.05% of reading
High Select Average (Single point,
Pen response: 1 second to full scale
(A>B -> A) cumulative since reset)
Channel update rate: 250ms
CJC rejection: ±0.5% from 25°C Low Select
Noise Rejection (48 to 62Hz): (A>B -> B)
Common mode: >130dB (Channel to Channel Table 2
and Channel to Ground)
Series Mode: >60dB Customer Linearisation Tables
Input Impedance: >20MΩ No. Of tables available: 1
No. Of point pairs: 11
Power Requirements
Line voltage (45- 65Hz): 90 to 132 Volts or 180 to 264 Volts Relay Outputs
(User selectable) Maximum number or relays: 8 (two boards)
Low voltage option: 24V dc Maximum switching power*: 60W
Power: <25VA (115VA with case heater) Maximum breaking current*: 2 Amps within above power ratings
25W dc Maximum contact voltage*: 250V ac within above power ratings
Fuse: 20mm Slow blow 500mA/240V ac or 30V dc within above power ratings
20mm slow blow 1A/120V ac * With resistive loads
20mm slow blow 2A/24V dc
Recorder supply voltage (mains) fuse Analogue (retransmission) Outputs
must not exceed 3A Max No. of Outputs: 4 (2 boards)
Output Ranges: Voltage: 0 to 5V dc, or 1 to 5V dc
Environmental Performance
Current: 0 to 20mA, or 4 to 20mA (into 1000Ω)
Temperature Limits:
Operation: 0 to 50°C Event Inputs
(-20 to 50°C with heater) Max No. of inputs: 16 (2 boards)
Storage: -20 to +70°C
Humidity Limits (non - condensing:) 10 to 90%
Transmitter Power Supply
Protection: Standard: NEMA3 (IP54)
Supply: 4 Isolated 28V dc, 24mA supplies
Waterproof: NEMA4 (IP65)
115V ac Supply – 100mA/250V T
Shock: BS EN60873 and BS EN61010
(slow blow)
Vibration (EN60873): 1g peak at 60Hz to 150Hz
240V ac Supply – 63mA/250V T
Altitude (max.): <2000 metres
(slow blow
Electromagnetic compatibility (EMC)
Emissions: BS EN50081-2 Controllers
Immunity: BS EN50082-2 Number: 2
Electrical safety: BS EN61010 Type: Single or Dual output, 3-node
Installation Cat. II; Pollution degree PID controllers, setpoint generators
and remote/local setpoint switching
INSTALLATION CATEGORY II
The rate impulse voltage for equipment on nominal 230V mains is 2500V.

POLLUTION DEGREE 2
Normally, only non-conductive pollution occurs. Occasionally, however, a
temporary conductivity caused by condensation shall be expected
Mechanical installation

Bezel/door outline
345.5mm Wide x Bolt
340.5mm High Spring washer
+2 Panel cutout
both –0 mm Washer

13.60 inches Wide x


13.41 inches High
both +– 00.08 in.

Mounting Technique
Panel cutout

Signal wiring

+1 2 –3 +1 2 –3 +1 2 –3 +1 2 –3 +1 2 –3 +1 2 –3

Shunt
+ — assembly Attenuator
assembly
+ — + —
DC V (—1V to 5V) DC V 3-wire resistance 2-wire resistance
DC mV DC mA —10 to 100V DC Potentiometer
thermometer thermometer
Thermocouples

250‰ = AH203447U002 Attenuator = AH203447U006

Supply voltage and I/O board wiring

Pins for Shunt Line Voltage


Card Cables
– +
Selector switch
115 115/230V
Trans P.S.
1234

Main Board Supply Voltage


Line (L)
Neutral (L2/N)
Card 2 Relays,
Retrans & Connected to Earth ground
Contact
Channels Input Cards Contact Inputs Retrans Outputs
3 & 4
5 6 7 8
1 & 2
+ – 1 2 3 4
8 7 C 6 5 C 4 3 C 2 1 C + – + –
A B

Earth Ground

Shunt/ +1 2 –3 NC C NO
Divider Channel 1 Relay #1
Input Card Direct Input Terminals Terminals
Eurotherm: International sales and service
Understanding and providing local support is a key part of Eurotherm's business. Complementing worldwide Eurotherm offices are a whole
range of partners and a comprehensive technical support team… to ensure you get a service you will want to go back to.
AUSTRALIA Sydney FRANCE Lyon IRELAND Dublin SPAIN Madrid
Eurotherm Pty. Ltd. Eurotherm Automation SA Eurotherm Ireland Limited Eurotherm España SA
T (+61 2) 9838 0099 T (+33 478) 664500 T (+353 1) 4691800 T (+34 91) 6616001
F (+61 2) 9838 9288 F (+33 478) 352490 F (+353 1) 4691300 F (+34 91) 6619093
E info.au@eurotherm.com E info.fr@eurotherm.com E info.ie@eurotherm.com E info.es@eurotherm.com
AUSTRIA Vienna GERMANY Limburg ITALY Como SWEDEN Malmo
Eurotherm GmbH Eurotherm Deutschland GmbH Eurotherm S.r.l Eurotherm AB
T (+43 1) 7987601 T (+49 6431) 2980 T (+39 31) 975111 T (+46 40) 384500
F (+43 1) 7987605 F (+49 6431) 298119 F (+39 31) 977512 F (+46 40) 384545
E info.at@eurotherm.com E info.de@eurotherm.com E info.it@eurotherm.com E info.se@eurotherm.com
BELGIUM & LUXEMBOURG Moha HONG KONG & CHINA KOREA Seoul SWITZERLAND Wollerau
Eurotherm S.A/N.V. Eurotherm Limited North Point Eurotherm Korea Limited Eurotherm Produkte (Schweiz) AG
T (+32) 85 274080 T (+85 2) 28733826 T (+82 31) 2738507 T (+41 44) 7871040
F (+32) 85 274081 F (+85 2) 28700148 F (+82 31) 2738508 F (+41 44) 7871044
E info.be@eurotherm.com E info.hk@eurotherm.com E info.kr@eurotherm.com E info.ch@eurotherm.com
BRAZIL Campinas-SP Guangzhou Office NETHERLANDS Alphen a/d Rijn UNITED KINGDOM Worthing
Eurotherm Ltda. T (+86 20) 8755 5099 Eurotherm B.V. Eurotherm Limited
T (+5519) 3707 5333 F (+86 20) 8755 5831 T (+31 172) 411752 T (+44 1903) 268500
F (+5519) 3707 5345 E info.cn@eurotherm.com F (+31 172) 417260 F (+44 1903) 265982
E info.br@eurotherm.com Beijing Office E info.nl@eurotherm.com E info.uk@eurotherm.com
T (+86 10) 6567 8506 www.eurotherm.co.uk
DENMARK Copenhagen F (+86 10) 6567 8509 NORWAY Oslo
Eurotherm Danmark AS E info.cn@eurotherm.com Eurotherm A/S U.S.A. Leesburg VA
T (+45 70) 234670 T (+47 67) 592170 Eurotherm Inc.
F (+45 70) 234660 Shanghai Office F (+47 67) 118301 T (+1 703) 443 0000
E info.dk@eurotherm.com T (+86 21) 6145 1188 E info.no@eurotherm.com F (+1 703) 669 1300
F (+86 21) 6145 1187 E info.us@eurotherm.com
FINLAND Abo E info.cn@eurotherm.com POLAND Katowice www.eurotherm.com
Eurotherm Finland INDIA Chennai Invensys Eurotherm Sp z o.o. ED53
T (+358) 22506030 Eurotherm India Limited T (+48 32) 2185100
F (+358) 22503201 T (+91 44) 24961129 F (+48 32) 2177171
E info.fi@eurotherm.com F (+91 44) 24961831 E info.pl@eurotherm.com
E info.in@eurotherm.com

© Copyright Eurotherm Limited 2006


Invensys, Eurotherm, the Eurotherm logo, Chessell, EurothermSuite, Mini8, Eycon, Eyris and Wonderware are trademarks of Invensys plc, its subsidiaries and affiliates. All other brands may be trademarks of their respective owners.
All rights are strictly reserved. No part of this document may be reproduced, modified, or transmitted in any form by any means, nor may it be stored in a retrieval system other than for the purpose to act as an aid in
operating the equipment to which the document relates, without the prior written permission of Eurotherm limited.
Eurotherm Limited pursues a policy of continuous development and product improvement. The specifications in this document may therefore be changed without notice.
The information in this document is given in good faith, but is intended for guidance only. Eurotherm Limited will accept no responsibility for any losses arising from errors in this document.

Part No. HA027724 Issue 2 392 Circular Chart Recorder Specification Sheet Printed in England 12.06