Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

Signet 9900 Transmitter

Member of the SmartPro™ Family of Instruments


Features
• Multi-Parameter input selection

• Large auto-sensing backlit display with


“at a glance” visibility

• “Dial-type” digital bar graph

• Intuitive and “user-friendly” interface


consistent with legacy Signet ProPoint® and
ProcessPro® devices

• Optional field upgradable relays

• Selectable error mode for current outputs,


3.6 mA or 22 mA
Panel Mount Field Mount
• 4 to 20 mA input (with optional 8058 Signal
Converter)

• Warning LED indicator

The Signet 9900 Transmitter provides a single channel • Custom 13-character label capabilities for
the channel type
interface for many different parameters including Flow,
pH/ORP, Conductivity/Resistivity, Salinity, Pressure, • Factory reset capability
Temperature, Level and other sensors that output a 4 to
20 mA signal. The 9900 Transmitter (Generation II) has • Optional PC COMM configuration tool
the added capability of supporting the Batch Module for
batching control. The extra large (3.90” x 3.90”) auto- • Optional H COMM module for two-way
sensing backlit display features “at-a-glance” visibility communication
that can be viewed at 4-5 times the distance over
traditional transmitters. The highly illuminated display • Optional Batch Module for Batch Control
and large characters reduce the risk of misreading
or misinterpreting the displayed values. The display
shows separate lines for units, main and secondary MEASURING EQUIPMENT

measurements as well as a “dial-type” digital bar graph.


77CJ

The 9900 is offered in both panel or field mount versions. Applications


Both configurations can run on 12 to 32 VDC power (24 • Wastewater Treatment
VDC nominal). The 9900 can also be loop powered with • Reverse Osmosis
compatible sensors. • Deionization
– Ultra Pure Water
Designed for complete flexibility, plug-in modules – Two Bed System
allow the unit to easily adapt to meet changing – Mixed Bed System
customer needs. Optional modules include Relay, • Chemical Manufacturing/Addition
Direct Conductivity/Resistivity, H COMM, Batch and • Metal and Plastic Finishing
a PC COMM configuration tool. The unit can be used • Fume Scrubber
• Cooling Towers
with default values for quick and easy programming or
• Media Filtration
can be customized with labeling, adjustable minimum
and maximum dial settings, and unit and decimal
measurement choices.
Specifications
General
Input Channels One
Input Types Digital (S L)
3
Serial ASCII, TTL level, 9600 bps
Frequency Range 0.5 to 1500 Hz
Accuracy 0.5% of reading
Measurement Types Flow, pH/ORP, Conductivity/Resistivity, Salinity, Pressure, Temperature, Level, Batch or
user-defined (via 8058)
Enclosure and Display
Case Material PBT
Window Shatter-resistant glass
Keypad 4 buttons, injection-molded silicone rubber seal
Display Backlit, 7 and 14-segment
Update Rate 1s
LCD Contrast 5 settings
Indicators “Dial-type” digital bar graph. LEDs for Open Collector, Relays and Warning Indicator
Enclosure Size ¼ DIN
Mounting Panel ¼ DIN, ribbed on four sides for panel mounting clip inside panel, silicon gasket included
Field Mounts to standard Signet field mount junction boxes. Optional angle adjustment adapter available.
Wall Large enclosure (sold as an accessory) that encases the panel mount transmitter
Display Ranges
pH 0.00 to 15.00 pH
pH Temperature -99 °C to 350 °C -146 °F to 662 °F
ORP -1999 to 1999.9 mV
Flow Rate -9999 to 99999 units per second, minute, hour or day
Totalizer 0.00 to 99999999 units
Conductivity 0.0000 to 99999 μS, mS, PPM and PPB (TDS), kΩ, MΩ
Conductivity Temperature -99 °C to 350 °C –146 °F to 662 °F
Temperature -99 °C to 350 °C –146 °F to 662 °F
Pressure -40 to 1000 psi
Level -9999 to 99999 m, cm, ft, in, %
Volume 0 to 99999 cm3, m3, in3, ft3, gal, L, lb, kg, %
Salinity 0 to 100 PPT
Environmental
Ambient Operating Temperature
Backlit LCD -10 °C to 70 °C 14 °F to 158 °F
Storage Temperature -15 °C to 70 °C 5 °F to 158 °F
Relative Humidity 0 to 100% condensing for field mount; 0 to 95% non-condensing for panel mount
Maximum Altitude 4,000 m (13,123 ft)
Enclosure Rating Designed to meet NEMA 4X/IP65 (front face only on panel mount); field mount is 100% NEMA
4X/IP65
Specifications (continued)
Electrical Requirements
Power to Sensors
Voltage +4.9 to 5.5 VDC @ 25 °C, regulated
Current 1.5 mA max in loop power mode (up to 2.0 mA with 24 V @ 300 Ω max. loop impedance);
20 mA max when using DC power
Short Circuit Protected
Isolation Low voltage (< 48V AC/DC) to loop with DC power connected
No isolation when using loop power only
Terminal Blocks Pluggable screw type 14 AWG max wire gauge
Input Power
DC 10.8 to 35.2 VDC, regulated
9900 without Relay Module 200 mA @ 10.8 VDC to 35.2 VDC
9900 with Relay Module 300 mA @ 10.8 VDC to 35.2 VDC
Overvoltage Protection 48 Volt Transient Protection Device
Current limiting for circuit protection
Reverse-Voltage Protection
Loop Power
No DC Power Input
Max. Loop Impedance 50 Ω @ 12 V 325 Ω @ 18 V 600 Ω @ 24 V
With DC Power Input
Max. Loop Impedance 250 Ω @ 12 V 500 Ω @ 18 V 750 Ω @ 24 V
Relay Specifications
Dry-Contact Relays (2) Open Collector (1)
Type SPDT N/A
Form C N/A
Max. Current Rating 5 A resistive 50 mA DC
Max. Voltage Rating 30 VDC or 250 VAC 30 VDC
Hysteresis Adjustable (absolute in engineering units) (EUs)
Latch Reset in test screen only
Delay 9999.9 seconds (max.)
Test Mode Set On or Off
Cycle Time 99999 seconds (max.)
Maximum Pulse Rate 400 pulses/minute
Proportional Pulse 400 pulses/minute
Volumetric Pulse Width 0.1 to 3200 s
Pulse Width Modulation 0.1 to 320 s
Input Types
Digital (S3L) or AC frequency
4 to 20 mA input via the 8058
pH/ORP input via the Digital (S3L) output from the 2750 pH/ORP Sensor Electronics
Raw Conductivity/Resistivity input directly from Signet Conductivity/Resistivity electrodes via Direct Conductivity/
Resistivity Module or via 2850
Input Specifications
Digital (S3L) Serial ACSII, TTL level, 9600 bps
Frequency Input
Sensitivity 80 mV @ 5 Hz, gradually increasing with frequency
Span 0.5 Hz to 1500 Hz @ TTL level input
Accuracy ± 0.5% or reading max error @ 25 °C
Resolution 1 μS
Repeatability ± 0.2% of reading
Specifications (continued)
Input Specifications continued
Power Supply
Rejection ±1 μA per volt
Short Circuit Protected
Update Rate (1/frequency) + 150 ms
Output Specifications
Current Output
Current Loop Output Standard ANSI-ISA 50.00.01 Class H
Current Output 4 to 20 mA, isolated, fully adjustable and reversible
Span 3.8 to 21 mA
Zero 4.0 mA factory set; user programmable from 3.8 to 5.0 mA
Full Scale 20.00 mA factory set; user programmable from 19.0 to 21.0 mA
Accuracy ±32 μA max. error @ 25 °C @ 24 VDC
Resolution 6 μA or better
Temperature Drift ±1 μA per °C
Power Supply Rejection ±1 μA per V
Isolation Low voltage (< 48 VAC/DC)
Voltage 12 to 32 VDC ±10%
Max. Impedance 250 Ω @ 12 VDC 500 Ω @ 18 VDC 750 Ω @ 24 VDC
(with DC power input)
Max. Impedance 50 Ω @ 12 VDC 325 Ω @ 18 VDC 600 Ω @ 24 VDC
(no DC power input)
Update Rate 150 mS nominal
Short circuit and reverse polarity protected
Adjustable Span Reversible
Error Condition Selectable error condition 3.6 or 22 mA
Actual update rate determined by sensor type
Test Mode Increment to desired current (range 3.8 to 21.00 mA)
Open Collector Output 50 mA DC max., 30 VDC
Shipping Weights
Base Unit 0.63 kg 1.38 lb
H COMM Module 0.16 kg 0.35 lb
Conductivity Module 0.16 kg 0.35 lb
Relay Module 0.19 kg 0.41 lb
Batch Module 0.16 kg 0.35 lb
Standards and Approvals
CE, UL, CUL, FCC

Dimensions RoHS Compliant, China RoHS


Manufactured under ISO 9001 and ISO 14001 for Environmental Management
and OHSAS 18001 for Occupational Health and Safety
99.06 mm
(3.90 in.)
3-9900.396
Angle Adjustment Adapter Kit
44.45 mm
29.97 mm (1.75 in.)
(1.18 in.) 107 mm
(4.21 in.) 88.90 mm
99.06 mm (3.50 in.)
3.50
(3.90 in.) 25°
Ref. 44.58 mm
(1.77 in.)
24.13 mm
91.44 mm (0.95 in.)
(3.60 in.)
88.90 mm 88.90
3.50mm
(3.50 in.) (3.50 in.)

54.10 mm
8.13 mm
(2.13 in.)
(0.32 in.)
Panel Mount Field Mount - Pipe, Tank, Wall

Signet Model 9900 Transmitter Signet Model 9900 Transmitter


(Includes mounting bracket and panel gasket) with Junction Box (varies with sensor and installation)

+ +
3-8050 3-8051-X 3-8052 3-9900.396
(optional)

Signet Sensors - Flow, Level, Temperature, Pressure


use one input with from a choice of sensors

FLOW

515 8510 525 2100 2507 2540 2450


2000 2537 2551 2552 2250 2350
2536 8512

Signet Fittings - See individual sensor data sheets All sold separately

Panel Mount Field Mount - Pipe, Tank, Wall

Signet Model 9900 Transmitter Signet Model 9900 Transmitter


(Includes mounting bracket and panel gasket) with Junction Box (varies with sensor and installation)
System Overview

+ +
3-8050 3-8052 3-9900.396
(optional)

Signet Sensors - pH/ORP Signet Wet-Tap Electrode Model 2756, 2757 and
use one input from a choice of sensors 3719 Wet-Tap with 2750 Sensor Electronics
With 2750 Sensor Electronics

+ +

Signet Fittings - See individual sensor data sheets All sold separately

Panel Mount Field Mount - Pipe, Tank, Wall

Signet Model 9900 Transmitter Signet Model 9900 Transmitter


(Includes mounting bracket and panel gasket) with 3-9900.396 Angle Adapter and Junction Box
(varies with sensor and installation)

+
3-9900.396* 3-8050 3-8052

Signet Sensors - Conductivity/Resistivity and Salinity Electrodes


use one input from a choice of electrodes with Conductivity Module or 2850 Sensor Electronics

+ OR

Signet Fittings - See individual sensor data sheets All sold separately

*3-9900.396 is required with the Conductivity Module and either 3-8050 or 3-8052 to provide sufficient clearance.
Plug in Modules
Optional modules are available to customize your 9900:
Relay Module (Panel mount only)
Direct Conductivity/Resistivity Module
H COMM Module
Batch Module

All modules come enclosed in a plastic cover. Modules are field installable and replaceable any time.
Relay Module (Panel Installations only)
wer
DC Po

Loop Vo
ltage
Dry-contact relays are electromechanical switches with
a moving contact armature. They are suitable for many
general purpose applications, AC or DC, including loads
up to 250 V. Install RC Filter kits (3-8050.396) on relays
used to switch motor or inductive loads.
3-9900.393 Relay Module

5A 30 VDC ‫׽׽‬
5A VAC

This module adds two programmable dry-contact relays


Rating:
~

to the standard Open Collector output in the base unit.


3-9900.393

Direct Conductivity/Resistivity Module


wer
DC Po

Loop
Voltage
The Direct Conductivity/Resistivity Module interfaces
Signet 2819-2823 and 2839-2842 Conductivity
electrodes directly to the 9900. The module also
provides filtering and conditioning. (Conductivity/
Resistivity and Salinity measurements may also be
SHIELD
TEMP (WHT)

odule
ISO GND (BLK)
SIGNAL (RED)

MM M
H CO

performed via the 2850 Sensor Electronics connected


through the 9900 Digital (S3L) inputs.).
Module
/Res
Cond

3-9900.394
H COMM Module (HART®)
wer
DC Po

ge
Volta

The H COMM Module enables communication between


Loop

the 9900 and a HART®-enabled device. The HART


(Highway Addressable Remote Transducer) Protocol
superimposes digital signals on top of the 4 to 20 mA
analog signal.
odule
MM M
H CO

Refer to the 9900 H COMM Module Manual 3-9900.094


for further details.
3-9900.395

Batch Module

The Batch Module adds batch capability to the 9900


Transmitter (Generation II). It is compatible with all
Signet flow sensors. Up to 10 batch sizes can be stored
in one 9900 with customised names and K-Factors
available for each batch.

Refer to the Batch Control System datasheet for further


details.
3-9900.397
Open Collector (R1) Indicator, LED
Mechanical Relay (R2)
Indicator, LED Backlight Sensor
Mechanical Relay (R3) Indicator, LED

Error Indicator
1 2 3 !

Bar Graph
Units of Measure
(example: GPM, pH, sec, %, etc.)

Value

Label

Menu Indication

Right Arrow Prompt

Menu Navigation Keys

ENTER

All possible segments shown in this illustration. The instrument’s software controls
which segments are shown at any particular time. Only the bar graph segment outline
and GF logo are visible when the unit is turned off.

The Angle Adjustment Adapter Kit enables the 9900


transmitter to be mounted virtually anywhere. Field
Mount Installations with a Conductivity/Resistivity
Module require the Angle Adjustment Adapter Kit for
wiring clearance.

3-9900-1 (159 001 696)


Field Mount

3-9900-396 (159 001 701)


Angle Adjustment Adapter Kit

3-8051 (159 000 187)


3-8051-1 (159 001 755)
3-8051-2 (159 001 756)
Flow Sensor Integral Mounting Kit
Ordering Information

Mfr. Part No Code Description


9900 Base Unit - Single Channel, Multi-Parameter, 4 to 20 mA, Open Collector, DC power
3-9900-1P 159 001 695 9900 Panel Mount Transmitter
3-9900-1 159 001 696 9900 Field Mount Transmitter
3-9900-1BC 159 001 770 Batch Controller System
Optional Accessory Modules
3-9900.393 159 001 698 Relay Module - 2 DCR (Dry-contact relays)
3-9900.394 159 001 699 Direct Conductivity/Resistivity Module
3-9900.395 159 001 697 H COMM Module
ule
s Mod
Cond/Re

3-9900.397 159 310 163 Batch Module


ule
M Mod
H COM

Accessories and Replacement Parts


Mfr. Part No Code Description
6682-0204 159 001 709 Conductivity Module Plug, 4 Pos, Right Angle
6682-1102 159 001 710 DC Power Plug, 2 Pos, Right Angle
6682-1103 159 001 711 Relay Module Plug, 3 Pos, Right Angle
6682-1104 159 001 712 Loop Power Plug, 4 Pos, Right Angle
6682-3004 159 001 725 Terminal Block Plug
6682-3104 159 001 713 Freq/S3L Plug, 4 Pos, Right Angle
7310-1024 159 873 004 24 VDC Power Supply, 0.42 A, 10W
7310-2024 159 873 005 24 VDC Power Supply, 1.0 A , 24W
7310-4024 159 873 006 24 VDC Power Supply, 1.7 A, 40W
7310-6024 159 873 007 24 VDC Power Supply, 2.5 A, 60W
7310-7024 159 873 008 24 VDC Power Supply, 4.0 A, 96W
3-0251 159 001 724 PC COMM Configuration Tool
3-8050 159 000 184 Universal Mount Kit
3-8050.396 159 000 617 RC Filter kit (for relay use), 2 per kit
3-8051 159 000 187 Flow Sensor Integral Mounting Kit, NPT, Valox
3-8051-1 159 001 755 Flow Sensor Integral Mounting Kit, NPT, PP
3-8051-2 159 001 756 Flow Sensor Integral Mounting Kit, NPT, PVDF
3-8052 159 000 188 ¾ in. Integral Mount Kit
3-8058-1 159 000 966 I-Go™ Signal Converter, wire-mount
3-8058-2 159 000 967 I-Go™ Signal Converter, DIN rail mount
3-9000.392-1 159 000 839 Liquid Tight Connector Kit, NPT (1 pc.)
3-9900.390 159 001 714 Standard Connector Kit, Right Angle, 9900 Transmitter
3-9900.391 159 001 715 Optional Connector Kit, In-Line, 9900 Transmitter
3-9900.392 159 001 700 Wall Mount Accessory Kit for 9900
3-9900.396 159 001 701 Angle Adjustment Adapter Kit (for Field Mounting)

3-9900.099 Rev E (04/13)


© Georg Fischer Signet LLC
3401 Aero Jet Avenue, El Monte, CA 91731-2882 U.S.A. • Tel. (626) 571-2770 • Fax (626) 573-2057 • www.gfsignet.com • e-mail: signet.ps@georgfischer.com
Specifications subject to change without notice. All rights reserved. All corporate names and trademarks stated herein are the property of their respective companies.

You might also like