FT 10 Datasheet en
FT 10 Datasheet en
FT 10 Datasheet en
The FT-10 family offers a comprehensive range of weighing indicators for Compact panel housing
both static and dynamic weighing as well as force measurement applications.
In total, 11 versions are available from basic functionality through to versions Max. conversion rate of 1 ,600
with additional I/O and a range of communication protocols, such as Modbus, updates per second
Profibus-DP, ProfiNET, EtherNet TCP/IP and CANopen.
Test weight or eCal calibration
Capable of 1,600 measurements/sec and with an accuracy of 0.0015% the FT-
10 is an ideal economic weight indicator. Particularly compact, the housing is Span adjustment under load
made of stainless steel and aluminium, ideal for industrial environments. A large
6-digit LED weight display (red 14 mm) allows easy readability even in poor light EU-Type Examination Certificate,
conditions. Tactile 5-key keyboard for basic scale functions. Applications include 10,000 e (R76)
universal weighing, process weighing, process automation & control, test and
measurement applications. Input sensitivity: 0.4 μV/e (legal-
for-trade), 0.1 μV/d (industrial)
The following device versions are available:
Bipolar analogue input range
FT-10 P (standard indicator) FT-10 EN (Ethernet TCP/IP) (-18…+18mV)
FT-10 IO (digital inputs and outputs) FT-10 CO (CANopen) Serial ports RS232C, RS485
FT-10 PN (ProfiNet)
RoHS
compliant IP65
Status Indicator gross, net, motion, zero, unit (kg, g, t, lb, klb, N, kN)
Keyboard 5-key membrane with tactile feedback (function, gross/net, tare/delete, zero, print)
Key lock Basic weighing related key can be locked against unauthorized access
a/d converter
Minimum input sensitivity 0.4 μV/d per interval legal for trade, 0.1 μV/d per interval non- approved
Resolution Internal up to 16 million counts; display up to 10,000 counts legal for trade, 999,999
counts non- approved
Calibration Calibration with weight or eCal (electronic calibration without test weights)
Weighing functions Tare, zero, auto zero tracking, motion detection, auto-zero at power-up, auto-net at pow-
er-up, increased resolution
load cells
Number of load cells Up to 8 load cells (350Ω) or 18 load cells (1,100Ω) in parallel
Connection 4-wire or 6-wire technology. Cable length 1,000 m/mm2 for 6-wire connection
Operation Temperature & -10 °C to +40 °C; 85% RH max, non-condensing, legal for trade
humidity
-15 °C to +55 °C non- approved
Housing & Protection Panel mount, plastic front Panel mount, stainless steel front panel (IP65), aluminium
panel (IP67), aluminium housing, stainless steel rear panel
housing, stainless steel rear
panel
serial interface
Serial Interface RS485 1,200 to 115,200 baud (8N1, 7E1, 701), up to 31 devices in a network
digital input/output
Input 2x I/O (non-isolated) pro- 4x opto-isolated input (12...26 VDC; max. 10mA)
grammable as digital input
Output (10...26 V DC) as well as dig- 5x relays outputs programable for user defined setpoints,
ital output (Open Collector: 250 VAC or 30 VDC, 1A
24 V DC, max. 100 mA)
analogue output