7.00 pH
Applications
Forbes Marshall, your trusted partner in - DM water
providing Water Quality analyzers in
- RO water
India, introduces the microcontroller
based 2-WIRE HART Transmitter, Field - Water treatment
Mount Aqua SMARTPro® series which - Chemical / Petrochemical
assures reliable and continuous
- Bio Pharma
measurement of parameters like pH,
Redox, Dissolved Oxygen, Conductivity, - Sugar/ Textile / Paper/ Food
Resistivity and Total Dissolved Solids - Power Plants
(TDS) which are of vital importance
- And many more
across the entire spectrum of
applications.
Dimension Drawing
General Specifications
Display
Local Display Two line dot matrix with 10 characters per line LCD display
Keypad
Keypad Three button keypad and magnetic pin programming with user friendly
menu interface.
Output
Current Output 4-20 mA DC, galvanically isolated output with accuracy better than
0.3% of full scale
Open Collector Outputs Three open collector outputs with max load of 100mA @ 24VDC,
(For Safe Area version only) galvanically isolated from the sensor and the output current for:
1. Error Detection
2. Over Range Detection
3. Under Range Detection
Note: External relay option available for potential free contact requirment.
Power Requirements
Mechanical Specifications
Protection Class IP 67
Environmental Conditions
pH
Range 0 – 14 pH
Resolution 0.01 pH
Accuracy +/- 0.01 pH
Span Minimum 2pH to Maximum 14pH (Programable)
mV (ORP)
Range +/- 2000 mV
Resolution +/- 1 mV
Accuracy +/- 1 mV
Span Minimum 200mV to maximum 4000 mV (Programmable)
Temperature
Range -20º C to +200º C
Resolution 0.01º C
Accuracy ± 0.5 % of FS
Sensor PT 100 (Default) / PT 1000
Compensation Automatic or Manual
Calibration
pH Sensor Slope 70% to 110%
pH sensor zero ± 2pH
Method Single / Double Point
Diagnostics
Measurement Mode Temperature Sensor Open
Temperature Sensor Short
Calibration Mode Slope Error
Zero Error
Calibration Error
Output
Current Output – pH/ORP Proportional to measured pH/ORP. Galvanically isolated from the sensor
with accuracy better than 0.3% of full scale
HART Superimposed on 4-20mA output
Conductivity
Range (with auto range facility) Measuring Range Cell Constant K Resolution
0 to 10 µS/cm 0.01 0.01
0 to 100 µS/cm 0.01 0.1
0 to 1000 µS/cm 0.1 0.1
0 to 10 mS/cm 1 0.01
0 to 100 mS/cm 10 0.01
Accuracy ± 0.5% of FS of Range
Span Minimum 5% to Maximum 100% of measurement range (Programmable)
Calibration
Conductivity Single point
Resistivity
Range (with auto range facility) Measuring Range Cell Constant K Resolution
100 MΩ.cm to 10 KΩ.cm 0.01 0.01
10 MΩ.cm to 1 KΩ.cm 0.1 0.1
1 MΩ.cm to 0.1 KΩ.cm 1 0.01
0.1 MΩ.cm to 0.01KΩ.cm 10 0.01
Accuracy ± 0.5% of FS of Range
Temperature
Range -20º C to +200º C
Resolution 0.01º C
Accuracy ± 0.5 % of FS
Sensor PT 100 (Default) / PT 1000
Compensation Automatic or Manual or Uncompensated (Programmable)
Diagnostics
Measurement Mode Sensor Open
Sensor Short
Temperature Sensor Open
Temperature Sensor Short
Calibration Mode Cell Constant error
Output
Current Output – Conductivity/ resistivity 4-20 mA galvanically isolated output proportional to the measured
conductivity value with accuracy better than 0.3% of full scale.
HART Superimposed on 4-20mA output
DO
Range (with auto range facility) Measuring Range Unit Resolution
0 to 500 % 0.1
50 to 9999 µg/l or PPB 1
0.05 to 20 mg/l or PPM 0.01
0.05 to 50 mg/l or PPM 0.1
Accuracy ± 0.5% of FS
Temperature
Range -10.0 to +150.0 Deg C
Resolution 0.01º C
Accuracy ± 0.5 % of FS
Sensor NTC 22 K Ohm
Compensation Automatic or Manual
Process parameter
Pressure 0 to 5 bar (Programmable)
Salinity 0 to 50 PPT (Programmable)
Humidity 0 to 100% (Programmable)
Calibration
DO Single/Dual point calibration
Diagnostics
Measurement Mode Sensor Short
Temperature Sensor Open
Temperature Sensor Short Calibration Mode
Unstable Current Output Error
Range Error
Output
Current Output 4-20 mA proportional to measured DO value. Galvanically isolated from
the sensor with accuracy better than 0.3% of full scale
HART Superimposed on 4-20mA output
FOR TDS – AquaTDS SMARTPro ® 8969
TDS
Range (with auto range facility) Measuring Range* Cell Constant K Resolution
0 to 7 ppm 0.01 0.01 ppm
0 to 70 ppm 0.01 0.01 ppm
0 to 700 ppm 0.1 0.1 ppm
0 to 7 ppt 1 0.01 ppm
0 to 70 ppt 10 0.1 ppm
*TDS ranges calculated considering TDS factor 0.7
Ordering Information
Opp 106th Milestone B-85, Phase II, Chakan Indl Area A-34/35, MIDC H Block
Bombay Poona Road Sawardari, Chakan, Tal. Khed Pimpri, Pune - 411 018. INDIA.
Kasarwadi, Pune - 411 034. INDIA Dist. Pune - 410 501. INDIA Tel : 91(0)20-27442020, 39851199
Tel : 91(0)20-27145595, 39858555 Tel : 91(0)2135-393400 Fax : 91(0)20-27442040
Forbes Marshall Fax : 91(0)20-27147413
Krohne Marshall CIN No.: U28996PN1985PTC037806
Forbes Marshall Arca Email : pasales@forbesmarshall.com, ccmidc@forbesmarshall.com www.forbesmarshall.com
Codel International
All contents herein are the property of Forbes Marshall Private Limited (“FMPL”) or Forbes Marshall Steam Systems Private
Forbes Solar Limited (“FMSSPL”), as the case may be, and having protection under the intellectual property rights. Any reproduction,
Forbes Vyncke distribution or disclosure without prior written permission is prohibited. Information in this document is subject to change
Forbes Marshall Steam Systems without notice.
DOC#FMPA/0316/1504/V3.R0