Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

0 2300 Dual Channel Monitor Datasheet 105m0340l

Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

GE Measurement & Control

2300 Vibration Monitors


Bently Nevada* Asset Condition Monitoring

Description
The 2300 Vibration Monitors provide cost-effective continuous
vibration monitoring and protection capabilities for less critical and
spared machinery. They are specifically designed to continuously
monitor and protect essential medium to low criticality machinery
in a wide range of industries including: oil & gas, power generation,
water treatment, pulp & paper, manufacturing, mining, cement,
and other industries.

The 2300 Vibration Monitors deliver vibration monitoring and high


vibration level alarming. They include two channels of seismic or
proximity measurement inputs from various accelerometer,
velomitor and proximitor types, a speed input channel for time-
synchronous measurements, and outputs for relay contacts. The
2300/20 monitor features a configurable 4-20 mA output which
interfaces more points to a DCS. The 2300/25 monitor features
System 1* connectivity for Trendmaster SPA interface which
enables users to leverage existing DSM SPA infrastructure.

The 2300 Vibration Monitors are designed for use on a broad


range of machine trains or individual casings where the sensor
point count fits the monitor’s channel count and where advanced
signal processing is desired.

Document: 105M0340
Rev. L (09/16)

Page 1 of 13
Monitor Key Features
2300/20 2300/25
 Two 4-20mA outputs  Trendmaster SPA interface
 Two relay outputs with programmable setpoints  Two relay outputs with programmable setpoints
 Ethernet 10/100 Base-T communication for  Ethernet 10/100 Base-T communication for
configuration using Bently Nevada Monitor configuration using Bently Nevada Monitor
Configuration software (included) Configuration software (included)
 One dedicated speed and Keyphasor* channel  One dedicated speed and Keyphasor channel
supporting Proximity probes, Magnetic pickup supporting Proximity probes, Magnetic pickup
and Proximity switch type sensors and Proximity switch type sensors
 Three buffered transducer outputs (including  Three buffered transducer outputs (including
Keyphasor signal) providing short circuit and EMI Keyphasor signal) providing short circuit and EMI
protection. Buffered outputs for each signal are protection. Buffered outputs for each signal are
through BNC connectors. through BNC connectors.
 Continuous monitoring and protection  Continuous monitoring and protection
 LCD display showing vibration measurements,  LCD display showing vibration amplitude,
setpoints, and speed setpoints, and speed
 Two acceleration/velocity/proximity inputs with  Two acceleration/velocity/proximity inputs with
synchronized sampling for advanced diagnostics synchronized sampling for advanced diagnostics
 Key measurements (Direct pk, Direct rms, Derived  Key measurements (Direct pk, Direct rms, Derived
pk, Velocity pk, Velocity rms, Displacement pp, pk, Velocity pk, Velocity rms, Displacement pp,
Displacement rms, Speed) real-time provided Displacement rms, Speed) real-time provided
with alarm configuration with alarm configuration
 LEDs show the monitor status  LEDs show the monitor status
 Local contacts for positive engagement of  Local contacts for positive engagement of
channel bypass, configuration lockout, and reset channel bypass, configuration lockout, and reset
 Modbus® over Ethernet  Modbus® over Ethernet

Recommended for Demonstration Kit


2300/20_KIT-003-02-01 To be ordered separately:
 1 - 2300/20 Monitor 110M7102-01 Power supply for DIN rail mounting,
100/240AC to 24DC/1.3A
 1 - 6 ft. (1.8M) shielded Ethernet cable
(-25°C ~70°C, 22.5*99*107 mm)
 2 - Accelerometer sensors
 2 - 15 ft. (4.8M) accelerometer cables
 100M9465-01 BN Monitor Configuration
SW/FW DVD

Document: 105M0340
Rev. L (09/16)

Page 2 of 13
Specifications
Speed/Keyphasor Inputs
 Supported Keyphasor transducers include:
Inputs / Outputs
o Proximity probe
Power Input: o Proximity switch
 DC Input: 18~36VDC, max 7.5W o Magnetic Pickup
 Supports ICP Accelerometers Channel Type:  Supports multiple events per revolution and
o Configurable Bandpass filter: 0.2 Hz to 20 event ratios for speed inputs up to 20 kHz
kHz  Threshold voltage resolution: 0.1VDC
o Scale Factor range: 5 to 1000 mV/g  Proximity Transducer Interface:
o Full scale range: 2 to 80 g peak o Supply Voltage: -22.8 to –25.2 VDC
o Bias output voltage: -12VDC (for AM3100T2- o Maximum Rated Current: 15 mA
Z2)
o Short Circuit Current: 15.1 mA to 23.6 mA
o Configurable Upper OK limit: -0.25 to -22 V
(greater than lower ok) o Accuracy: ±1% of full scale range

o Configurable Lower OK limit: -0.25 to -22 V o Input Impedance: 3-wire Voltage Mode, 10
(less than upper ok) kΩ

o Current Sink Source: 3.3 mA ± 5% o Rpm range: 1 to 120,000

o Open Circuit Voltage: -21 to -24 VDC  Proximity Switch Interface:

 Supports Velocity Channel Type: o Supply Voltage: -10 to -24 VDC

o Configurable Bandpass filter: 0.2 Hz to 20 o Lower Not Ok limit: -2.75 ±0.05 V


kHz o Rpm range: 1 to 120,000
o Scale Factor range: 5 to 1000 mV/in/s  Magnetic Pick up:
o Full scale range: 0 to 50 in/s peak o Input voltage up to ±125V (250Vp-p)
o Configurable Upper OK limit: -0.25 to -22 V o Rpm range: 200 to 120,000
(greater than lower ok)
Contact Inputs
o Configurable Lower OK limit: -0.25 to -22 V
(less than upper ok) Monitor provides the capability of 3 contact inputs
with terminals. One is used for configuration lock,
 Supports Radial Vibration Channel Type: one is for latched alarm/relay reset function, and the
o Configurable Bandpass filter: 0.2 Hz to 20 3rd one is used for monitor Alarm/Relay Inhibit.
kHz  Activate: 0 to 10 kΩ
o Scale Factor range: 5 to 1000 mV/mil  De-activate: 150 kΩ to infinite
o Full scale range: 0 to 160 mil peak-peak Button Inputs
o Configurable Upper OK limit: -0.25 to -22 V  External button to reset latched alarm and relay
(greater than lower ok)
 One buried button provides 3 functions:
o Configurable Lower OK limit: -0.25 to -22 V
(less than upper ok) o Display monitor information including:

 Accuracy: ±1% of full scale range  User account name

 Supports custom accelerometers (2 or 3 wires)  IP address

 Independent 24-bit ADCs on both channels  FW/HW version

Document: 105M0340
Rev. L (09/16)

Page 3 of 13
o LCD contrast adjustment o Maximum switched contact voltage and
current: 6A @24VAC / 5A @30VAC / 5.8A
o Reset settings to default including:
@24VDC / 4A @30VDC
 User account name
4-20mA Output (2300/20)
 Password
 Two 4-20mA outputs
 Network configuration
 4 to 20mA output values are proportional to the
Jumper between COM & Chassis GND full-scale of the associated measurement
 There is a 2-pin terminal interface which allows  Each output can be software configured to
connection of COM and Chassis GND together. output any variable
 Alternatively, COM can be connected to earth  Voltage compliance: 0 to +12Vdc range across
ground separately through a terminal. load
Buffered Output  Load resistance: 0 to 600Ω
 There are three buffered outputs available on the  Resolution: 0.3662uA
monitor through BNC connectors:
 Accuracy: 1% over operating temperature range
o 2 Vibration Outputs
 Update rate: 100ms
o 1 Speed Output
 Configurable with default 2mA clamp current
Relay Output
 No output feedback determination
 There are two dry-contact relay outputs
SPA Output (2300/25)
 May be normally energized or de-energized
 Input signal range
 No output feedback determination
o High AC: 8Vpp
 Relay circuit specification in Non-Hazardous
o Low AC: 1.6Vpp
area:
o DC GAP: 0 to -20Vdc (max measurable AC
o Type: Single pole, double throw
signal is 1Vpp)
o Sealing: Epoxy sealed
 Accuracy
o Contact life:
o High/Low AC: ±1% of Full-Scale at 100Hz
100,000 cycles @ 5 amps 250 VAC
200,000 @ 1 amp, 24 VDC o DC GAP: ±0.5V (measurable AC accuracy:
±20mV)
o Insulation resistance:
1000 MΩ minimum @ 500 VDC  Frequency response
o Relay closed contact resistance: o 10Hz to 3000Hz ±5%
1 Ω maximum
LEDs
o Relay open contact resistance:
 OK: Indicates when the monitor is operating
1 MΩ minimum
properly
o Maximum switched contact voltage:
 Protection fault: Indicates that there is a
250V AC /250V DC
hardware fault that is impacting alarm
o Maximum breaking contact current: determination
6A @250VAC / 6A @24VDC
 User inhibit: indicates the alarm/relays have been
o Maximum switched power: intentionally inhibited from operation
1500VA AC / 150 Watts DC
 Bypass: indicates user initiated bypass action
 Relay circuit specification in Hazardous area:
 Relay status: indicates if relays have been
activated

Document: 105M0340
Rev. L (09/16)

Page 4 of 13
 TX/RX: Indicates the Ethernet status and monitor 2014/35/EU Low Voltage
communicating with remote software Standard:
 Speed channel status EN61010-1: 2010
 Channel Alarm Status: European Community Directives:
LV Directive 2014/35/EU
o Alert LED: engages if any channel is in alert
state
EMC
o Danger LED: engages if any channel is in Standards:
danger state EN61000-6-2 Immunity for Industrial Environments
EN61000-6-4 Emissions for Industrial Environments
LCD
EN61326-1 Electrical equipment for measurement,
LCD display allows viewing machine speed, vibration control and laboratory use - EMC requirements
measurements value, setpoints, and configuration
information. European Community Directives:
EMC Directive 2014/30/EU
Communications
Hazardous Area Approvals
Ethernet
For a detailed listing of country and product
 Ethernet, 10Base-T and 100Base-TX. Conforms specific approvals, refer to the Approvals Quick
to IEEE802.3 Reference Guide (document 108M1756) located at
 RJ-45 for 10Base-T/100Base-TX Ethernet cabling the following website: www.GEmeasurement.com.

 Cable length: 100 meters (328 ft.) maximum CSA/NRTL/C

Environmental Limits Class I, Division 2/Zone 2


AEx/Ex nA nC [ic] IIC T4 Gc
Class I, Div. 2, Groups A, B, C, D
Operating Temperature: ATEX/IECEx
 -30 °C to +65 °C (-22 °F to +149 °F) II 3 G
Storage Temperature: Ex nA nC [ic] IIC T4 Gc
ATEX 2014/34/EU
 -40 °C to +85 °C (-40 °F to +185 °F)
Humidity:
Intrinsic Safety Parameters:
 Up to 95%, non-condensing
For Proximitor Transducer:
Vibration Limitation: Uo: 24V; Io: 46mA; Co: 200nF; Lo: 1mH
 3g For Accelerometer Transducer:
Uo: 24V; Io: 3.3mA; Co: 200nF; Lo: 1mH
Battery Life for Real Time Clock:
FOR SPA POWER (2300/25 Only):
 Powered: 38 years @ 50°C (122 °F) Ui=15V; Ii=150mA; Pi=560mW; Ci=0; Li=0
 Un-powered: 12 years @ 50°C (122 °F) FOR SPA SIGNAL (2300/25 Only):
Ui=12V; Ii=12mA; Pi=36mW; Ci=0; Li=0

Compliance and Certifications


Physical
General and Electrical Safety:
Dimensions (Width x Depth x Height)
UL Std. No. 61010-1 (3rd Edition)
127mm x 127mm x 76.2mm (5in x 5in x 3in)
CAN/CSA C22.2 No. 61010-1-12
Weight
1.03kg (2.26lbs)

Document: 105M0340
Rev. L (09/16)

Page 5 of 13
Mounting 002
Panel mount or DIN rail (adapter included) 1 - 2300/20 or 2300/25 Monitor
Ordering Information 1 - 6 ft. shielded Ethernet cable

For a detailed listing of country and product 1 - 13x15x8 in. fiberglass housing with
specific approvals, refer to the Approvals Quick window
Reference Guide (document 108M1756) located at 1 - Accelerometer sensor
the following website: www.GEmeasurement.com.
1 - 15 ft. (4.8m) accelerometer cable
2300 Series Vibration Monitor
(Excluding Keyphasor sensor and 24VDC
power supply1)
2300/20-AA-BB: Monitor with 4-20ma Outputs 003
(including DIN rail mount assembly, manual and
monitor configuration software) 1 - 2300/20 or 2300/25 Monitor
1 - 6 ft. shielded Ethernet cable
2300/25-AA: Monitor with SPA Outputs (including
DIN rail mount assembly, manual and monitor 2 - Accelerometer sensors
configuration software)
2 - 15 ft. (4.8m). accelerometer cables
AA: Approvals Option (Excluding Keyphasor sensor, enclosure
00 and 24 VDC power supply1)
None
02 BB: Approvals Option
Multiple Explosive Atmosphere 00
Certifications (ATEX/IECEx/CSA) None
02
BB: Software License for System 1 Evo Connection Multiple Explosive Atmosphere
00 Certifications (ATEX/IECEx/CSA)
Monitor without License
01 CC: Software License for System 1 Evo Connection
Monitor with License 00
Monitor without License
01
2300/20_KIT-AAA-BB-CC: Bently Nevada 2300/20 Monitor with License
Condition Monitoring System Kit

2300/25_KIT-AAA-BB: Bently Nevada 2300/25


Condition Monitoring System Kit 3071/13-AA-BB: System 1 2300 Series Device Import
AAA: Configuration AA: Not available for 2300 monitor
00
001
1 - 2300/20 or 2300/25 Monitor BB: Quantity of 2300 Monitoring Systems
## - Numeric Entry [1->n]
1 - 6 ft. (1.8m) shielded Ethernet cable
1 – 13 x 15 x 8 in. (338 x 389 x 209mm) Notes:
fiberglass housing with window  3071/13 is only applicable for 2300 monitors that
2 - Accelerometer sensors are installed/purchased without the System 1
Evolution device license.
2 – 15 ft. (4.8m) accelerometer cables
 System 1 Evolution software requires a separate
(Excluding Keyphasor sensor and 24 VDC order. Refer to the System 1 datasheet
power supply 1)
Document: 105M0340
Rev. L (09/16)

Page 6 of 13
(document 108M5214) for detailed ordering
information.
105M6193-01 Fiberglass NEMA 4X/IP68
 The maximum number of 2300 monitor weatherproof housing with window
connections is 350 in System 1 16.1. (This number in door (includes mounting plate for
will be increased in later versions.) monitor)
 AA option is for vbOnline Pro Device. Dimensions:
(Width x Depth x Height)
338.3 x 389.1 x 209.8mm
1 We provide 3 kinds of power supplies with different temperature (13.3 x 15.3 x 8.2in)
range and different power. Please check Accessories below for
the details.

Accessories

106M7607-01 Power supply for DIN rail mounting,


100/240AC to 24DC/1.5A
Certifications (ATEX)
(-25°C ~70°C, 35*99*95 mm)
(One power can drive max 4
monitors)
AM3100T2-Z2 Accelerometer sensor
110M7102-01 Power supply for DIN rail mounting,
100/240AC to 24DC/1.3A
Certifications (CID2 by UL)
(-25°C ~70°C, 22.5*99*107 mm)
(One power can drive max 4
monitors.)
106M6694-01 Power supply for DIN rail mounting,
110/220AC to 24VDC/5A
Certifications (ATEX, IECEx, CID2 by
UL)
(-40°C ~70°C, 40*130*125 mm)
(One power can drive max 10
monitors.)

Document: 105M0340
Rev. L (09/16)

Page 7 of 13
330500 Velomitor

330400/330425 Accelerometer sensor 330505 Velomitor

330525 Velomitor

190501 Velomitor

100M0741 Proximity Switch

Document: 105M0340
Rev. L (09/16)

Page 8 of 13
284947 Magnetic Pickup Splash Proof Cable for AM3100T2-Z2
Accelerometer

9571 Mod : 285031-AA* Cable for 2 wire extension


with a splash proof connection. This
cable assembly will provide an
equivalent IP66 level of protection.
*Note : Cable lengths greater than 30 meters (100
feet) will experience some attenuation of
amplitudes at higher frequencies when using the
Proximity Probes AM3100T2-Z2 Accelerometer.
AA :
Please refer to proximity probe datasheet for details
16 16 ft. (4.8 m)
172036 3300 5mm
32 32 ft. (9.8 m)
141194-01 3300XL 8mm 64 64 ft. (19.5 m)

146256-01 3300XL 11mm 286244 Magnetic mounting base ¼-28


threaded hole
147385-01 3300XL NSV
Ethernet Cables
02120015 Bulk Cable from Proximity sensor to
monitor (500 ft.)
138131-AAA Standard 10 Base-T/100 Base-TX
9571-AA* Low cost cable for accelerometer Shielded Category 5 Cable with
RJ-45 connectors (solid conductor)
AA: From “20” to “99” Increments of 1.0 foot
AAA: Cable Length
006 6 ft. (1.8 m)
010 10 ft. (3.0 m)
025 25 ft. (7.6 m)
040 40 ft. (12.2 m)
050 50 ft. (15.2 m)
075 75 ft. (22.9 m)
84661-AA* Armored cable for accelerometer 085 85 ft. (25.9 m)
100 100 ft. (30.5 m)
AA: From “30” to “99” Increments of 1.0 foot

Spares

105M6203-01 35mm DIN rail mount and screws


(included with 2300/20 monitor)

106M3210 10 pins 4-20mA output connector

106M2223 5 pins contact input connector


CB2W100-AAA Cable for Velomitor CT (Alarm Reset)
AAA:
106M3408 5 pins contact input connector
015 15 ft. (4.8 m)
(Alarm Inhibit, Config lock)
032 32 ft. (9.8 m)
064 64 ft. (19.5 m) 106M3211 16 pins transducer input connector
112 112 ft. (34.1 m)
125 125 ft. (38.1 m) 106M3212 6 pins relay output connector
150 150 ft. (45.7 m)
200 200 ft. (61.0 m) 106M2231 3 pins power input connector
250 250 ft. (76.2 m)

Document: 105M0340
Rev. L (09/16)

Page 9 of 13
Software Training Materials Link

100M9465-01 BN Monitor Configuration SW/FW http://ge-


DVD energy.turnstilesystems.com/ProgramDetail.aspx/23
00Monitor
 BNMC version 5.2 or greater
 2300 series monitor firmware
(DVD includes 2300 Series Software
Guide)

User Manuals

2300 Series Operation and Maintenance Manual


(Document 105M0341)
2300 Field Wiring Diagram (Document 106M5801)

2300 Series Software Guide (Document 107M7626)

Document: 105M0340
Rev. L (09/16)

Page 10 of 13
Graphs and Figures

2300 Series Monitor Recommended Clearance

Document: 105M0340
Rev. L (09/16)

Page 11 of 13
Wiring Diagram

2300/20 Wiring Diagram

Document: 105M0340
Rev. L (09/16)

Page 12 of 13
2300/25 Wiring Diagram

Note: 2300/20 and 2300/25 use the same interface connector for recorder output or SPA output.

Modbus® is a registered trademark of Schneider Electric USA, INC.

© 2014-2016 Bently Nevada, Inc. All rights reserved.


* Denotes a trademark of Bently Nevada, Inc., a wholly owned subsidiary of General Electric Company.
The information contained in this document is subject to change without prior notice.
Printed in USA. Uncontrolled when transmitted electronically.
1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 775.782.3611 Fax: 775.215.2873
www.GEmeasurement.com

Document: 105M0340
Rev. L (09/16)

Page 13 of 13