0 2300 Dual Channel Monitor Datasheet 105m0340l
0 2300 Dual Channel Monitor Datasheet 105m0340l
0 2300 Dual Channel Monitor Datasheet 105m0340l
Description
The 2300 Vibration Monitors provide cost-effective continuous
vibration monitoring and protection capabilities for less critical and
spared machinery. They are specifically designed to continuously
monitor and protect essential medium to low criticality machinery
in a wide range of industries including: oil & gas, power generation,
water treatment, pulp & paper, manufacturing, mining, cement,
and other industries.
Document: 105M0340
Rev. L (09/16)
Page 1 of 13
Monitor Key Features
2300/20 2300/25
Two 4-20mA outputs Trendmaster SPA interface
Two relay outputs with programmable setpoints Two relay outputs with programmable setpoints
Ethernet 10/100 Base-T communication for Ethernet 10/100 Base-T communication for
configuration using Bently Nevada Monitor configuration using Bently Nevada Monitor
Configuration software (included) Configuration software (included)
One dedicated speed and Keyphasor* channel One dedicated speed and Keyphasor channel
supporting Proximity probes, Magnetic pickup supporting Proximity probes, Magnetic pickup
and Proximity switch type sensors and Proximity switch type sensors
Three buffered transducer outputs (including Three buffered transducer outputs (including
Keyphasor signal) providing short circuit and EMI Keyphasor signal) providing short circuit and EMI
protection. Buffered outputs for each signal are protection. Buffered outputs for each signal are
through BNC connectors. through BNC connectors.
Continuous monitoring and protection Continuous monitoring and protection
LCD display showing vibration measurements, LCD display showing vibration amplitude,
setpoints, and speed setpoints, and speed
Two acceleration/velocity/proximity inputs with Two acceleration/velocity/proximity inputs with
synchronized sampling for advanced diagnostics synchronized sampling for advanced diagnostics
Key measurements (Direct pk, Direct rms, Derived Key measurements (Direct pk, Direct rms, Derived
pk, Velocity pk, Velocity rms, Displacement pp, pk, Velocity pk, Velocity rms, Displacement pp,
Displacement rms, Speed) real-time provided Displacement rms, Speed) real-time provided
with alarm configuration with alarm configuration
LEDs show the monitor status LEDs show the monitor status
Local contacts for positive engagement of Local contacts for positive engagement of
channel bypass, configuration lockout, and reset channel bypass, configuration lockout, and reset
Modbus® over Ethernet Modbus® over Ethernet
Document: 105M0340
Rev. L (09/16)
Page 2 of 13
Specifications
Speed/Keyphasor Inputs
Supported Keyphasor transducers include:
Inputs / Outputs
o Proximity probe
Power Input: o Proximity switch
DC Input: 18~36VDC, max 7.5W o Magnetic Pickup
Supports ICP Accelerometers Channel Type: Supports multiple events per revolution and
o Configurable Bandpass filter: 0.2 Hz to 20 event ratios for speed inputs up to 20 kHz
kHz Threshold voltage resolution: 0.1VDC
o Scale Factor range: 5 to 1000 mV/g Proximity Transducer Interface:
o Full scale range: 2 to 80 g peak o Supply Voltage: -22.8 to –25.2 VDC
o Bias output voltage: -12VDC (for AM3100T2- o Maximum Rated Current: 15 mA
Z2)
o Short Circuit Current: 15.1 mA to 23.6 mA
o Configurable Upper OK limit: -0.25 to -22 V
(greater than lower ok) o Accuracy: ±1% of full scale range
o Configurable Lower OK limit: -0.25 to -22 V o Input Impedance: 3-wire Voltage Mode, 10
(less than upper ok) kΩ
Document: 105M0340
Rev. L (09/16)
Page 3 of 13
o LCD contrast adjustment o Maximum switched contact voltage and
current: 6A @24VAC / 5A @30VAC / 5.8A
o Reset settings to default including:
@24VDC / 4A @30VDC
User account name
4-20mA Output (2300/20)
Password
Two 4-20mA outputs
Network configuration
4 to 20mA output values are proportional to the
Jumper between COM & Chassis GND full-scale of the associated measurement
There is a 2-pin terminal interface which allows Each output can be software configured to
connection of COM and Chassis GND together. output any variable
Alternatively, COM can be connected to earth Voltage compliance: 0 to +12Vdc range across
ground separately through a terminal. load
Buffered Output Load resistance: 0 to 600Ω
There are three buffered outputs available on the Resolution: 0.3662uA
monitor through BNC connectors:
Accuracy: 1% over operating temperature range
o 2 Vibration Outputs
Update rate: 100ms
o 1 Speed Output
Configurable with default 2mA clamp current
Relay Output
No output feedback determination
There are two dry-contact relay outputs
SPA Output (2300/25)
May be normally energized or de-energized
Input signal range
No output feedback determination
o High AC: 8Vpp
Relay circuit specification in Non-Hazardous
o Low AC: 1.6Vpp
area:
o DC GAP: 0 to -20Vdc (max measurable AC
o Type: Single pole, double throw
signal is 1Vpp)
o Sealing: Epoxy sealed
Accuracy
o Contact life:
o High/Low AC: ±1% of Full-Scale at 100Hz
100,000 cycles @ 5 amps 250 VAC
200,000 @ 1 amp, 24 VDC o DC GAP: ±0.5V (measurable AC accuracy:
±20mV)
o Insulation resistance:
1000 MΩ minimum @ 500 VDC Frequency response
o Relay closed contact resistance: o 10Hz to 3000Hz ±5%
1 Ω maximum
LEDs
o Relay open contact resistance:
OK: Indicates when the monitor is operating
1 MΩ minimum
properly
o Maximum switched contact voltage:
Protection fault: Indicates that there is a
250V AC /250V DC
hardware fault that is impacting alarm
o Maximum breaking contact current: determination
6A @250VAC / 6A @24VDC
User inhibit: indicates the alarm/relays have been
o Maximum switched power: intentionally inhibited from operation
1500VA AC / 150 Watts DC
Bypass: indicates user initiated bypass action
Relay circuit specification in Hazardous area:
Relay status: indicates if relays have been
activated
Document: 105M0340
Rev. L (09/16)
Page 4 of 13
TX/RX: Indicates the Ethernet status and monitor 2014/35/EU Low Voltage
communicating with remote software Standard:
Speed channel status EN61010-1: 2010
Channel Alarm Status: European Community Directives:
LV Directive 2014/35/EU
o Alert LED: engages if any channel is in alert
state
EMC
o Danger LED: engages if any channel is in Standards:
danger state EN61000-6-2 Immunity for Industrial Environments
EN61000-6-4 Emissions for Industrial Environments
LCD
EN61326-1 Electrical equipment for measurement,
LCD display allows viewing machine speed, vibration control and laboratory use - EMC requirements
measurements value, setpoints, and configuration
information. European Community Directives:
EMC Directive 2014/30/EU
Communications
Hazardous Area Approvals
Ethernet
For a detailed listing of country and product
Ethernet, 10Base-T and 100Base-TX. Conforms specific approvals, refer to the Approvals Quick
to IEEE802.3 Reference Guide (document 108M1756) located at
RJ-45 for 10Base-T/100Base-TX Ethernet cabling the following website: www.GEmeasurement.com.
Document: 105M0340
Rev. L (09/16)
Page 5 of 13
Mounting 002
Panel mount or DIN rail (adapter included) 1 - 2300/20 or 2300/25 Monitor
Ordering Information 1 - 6 ft. shielded Ethernet cable
For a detailed listing of country and product 1 - 13x15x8 in. fiberglass housing with
specific approvals, refer to the Approvals Quick window
Reference Guide (document 108M1756) located at 1 - Accelerometer sensor
the following website: www.GEmeasurement.com.
1 - 15 ft. (4.8m) accelerometer cable
2300 Series Vibration Monitor
(Excluding Keyphasor sensor and 24VDC
power supply1)
2300/20-AA-BB: Monitor with 4-20ma Outputs 003
(including DIN rail mount assembly, manual and
monitor configuration software) 1 - 2300/20 or 2300/25 Monitor
1 - 6 ft. shielded Ethernet cable
2300/25-AA: Monitor with SPA Outputs (including
DIN rail mount assembly, manual and monitor 2 - Accelerometer sensors
configuration software)
2 - 15 ft. (4.8m). accelerometer cables
AA: Approvals Option (Excluding Keyphasor sensor, enclosure
00 and 24 VDC power supply1)
None
02 BB: Approvals Option
Multiple Explosive Atmosphere 00
Certifications (ATEX/IECEx/CSA) None
02
BB: Software License for System 1 Evo Connection Multiple Explosive Atmosphere
00 Certifications (ATEX/IECEx/CSA)
Monitor without License
01 CC: Software License for System 1 Evo Connection
Monitor with License 00
Monitor without License
01
2300/20_KIT-AAA-BB-CC: Bently Nevada 2300/20 Monitor with License
Condition Monitoring System Kit
Page 6 of 13
(document 108M5214) for detailed ordering
information.
105M6193-01 Fiberglass NEMA 4X/IP68
The maximum number of 2300 monitor weatherproof housing with window
connections is 350 in System 1 16.1. (This number in door (includes mounting plate for
will be increased in later versions.) monitor)
AA option is for vbOnline Pro Device. Dimensions:
(Width x Depth x Height)
338.3 x 389.1 x 209.8mm
1 We provide 3 kinds of power supplies with different temperature (13.3 x 15.3 x 8.2in)
range and different power. Please check Accessories below for
the details.
Accessories
Document: 105M0340
Rev. L (09/16)
Page 7 of 13
330500 Velomitor
330525 Velomitor
190501 Velomitor
Document: 105M0340
Rev. L (09/16)
Page 8 of 13
284947 Magnetic Pickup Splash Proof Cable for AM3100T2-Z2
Accelerometer
Spares
Document: 105M0340
Rev. L (09/16)
Page 9 of 13
Software Training Materials Link
User Manuals
Document: 105M0340
Rev. L (09/16)
Page 10 of 13
Graphs and Figures
Document: 105M0340
Rev. L (09/16)
Page 11 of 13
Wiring Diagram
Document: 105M0340
Rev. L (09/16)
Page 12 of 13
2300/25 Wiring Diagram
Note: 2300/20 and 2300/25 use the same interface connector for recorder output or SPA output.
Document: 105M0340
Rev. L (09/16)
Page 13 of 13