Professional Documents
Culture Documents
Elmr221 - 100 P 700054 e 00
Elmr221 - 100 P 700054 e 00
Master Module
Series ELMR221
timescales. The operating system re- S RS232 serial interface
presents the intelligence and functio-
S CAN--Bus (master) with CANopen
nality of the complete electronic sy-
protocol
stem. It includes interface communica-
tions, parameterisation, configuration, S automatic, and program--controlled,
I/O processing, recording/data log- data storage in flash EPROM
ging and parameter--driven control al-
gorithms (e.g. for controlling synchro- 1.3 Designed for
nous motion). The operating system is S the extreme mechanical stresses
in use in numerous applications and is that result from impacts and shock
therefore robust, and proven to a high loadings
degree.
S low and high ambient temperatures
1.2 Advantages while in operation
1 General S electrical data and equipment is opti- S the direct effects of dirt, water and
mised for use in the mobile industry dampness during field service
1.1 Product description
S programming to IEC 61131--3 S the large voltage fluctuations that are
The ELMR221 master module is used
as a controller in Bucher CAN bus sy- found in battery/alternator systemse
S detection of under-- and over--volta-
stems. ges S severe interference effects, whether
The module has 4 power outputs that radiated or conductor--linked, on the
S diagnostic functions for software and
can be suitably configured. The featu- entire electrical system
hardware
res of the operating system, which was
specially developed by Bucher Hy- S outputs are protected against short--
draulic, enable customer applications circuits and overloads; can be ex-
to be developed in significantly shorter amined by diagnostics
2 Technical data
Order--no: 100......
80
153
GNDS 01
VBBS 23
VBBO 05
Inputs Outputs
08 +VBBS
CYL 0 / FRQ 0 IN 0
(100 Hz...50 kHz) 40 %IX0.0 BL
12 GND +VBBO 20 OUT 0
BH %QX0.0 38
27 +VBBS GND 02
CYL 1 / FRQ 1 IN 1
(100 Hz...50 kHz) 41 %IX0.8 BL digital
22 GND e.g. two--way valve
11 +VBBS
IN 2
52 %IX1.0 BL
35 GND +VBBO 21 OUT 1
BH %QX0.8 39
30 +VBBS GND 03
IN 3
53 %IX1.8 BL PMW, current--controlled
17 GND e.g. proportional valve
09 +VBBS
IN 4
46 %IW6 A
04 GND +VBBO 36
OUT 2
BH %QX1.0 54
28 +VBBS GND 18
IN 5
47 %IW7 A
25 GND
10 +VBBS
IN 6
48 %IW8 A
34 GND +VBBO 37 +
OUT 3
BH %QX1.8 55
29 +VBBS GND 19 --
IN 7
49 %IW9 A PMW
16 GND z.B. Danfoss--
proportional valve
51 CAN_H (pull--down resistor integra-
ted)
50 CAN_L
15 CAN_GND For safety reasons the valve
CAN 1 is supplied with voltage via a
14 CAN_H
32 CAN_L binary output.
33 CAN_GND
Interfaces
43 CAN_H
44 CAN_L
26 CAN_GND
CAN 2
42 CAN_H
45 CAN_L
31 CAN_GND
07 TxD
06 RxD
RS232 13 GND
24 TEST
Abkürzungen
A = analog FRQ = frequency inputs VBBS = supply voltage outputs/module
BH = binary high side PWM = pulse--width--modulated signals
BL = binary low side RxD = serial interface (data received) %IWx = IEC--address for analog input
CANH = CAN--inerface TxD = serial interface (data transmitted) %IX0.xx = IEC--address for binary input
CANL = CAN--inerface VBBO = supply voltage outputs %QX0.xx = IEC--address for binary output
CYL = inputs for time perid measurement