Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                
Download as pdf or txt
Download as pdf or txt
You are on page 1of 18

41 150/417 ED

DS3
SOLENOID OPERATED
DIRECTIONAL CONTROL VALVE

SUBPLATE MOUNTING
ISO 4401-03

p max 350 bar


Q max 100 l/min

MOUNTING INTERFACE OPERATING PRINCIPLE

ISO 4401-03-02-0-05 40.5


(CETOP 4.2-4-03-350)
33
30.2
21.5

12.7
5.1 0.75
T
15.5
31 25.9 A B
31.75

— Direct acting, subplate mounting directional control


P
valve, with mounting surface according to ISO 4401-03
standards.
Ø7.5 (max)
Ø4
— The valve is supplied with 3 or 4 ways design, with 2 or
3 positions with a wide range of spools.
M5

— The valve body is made with high strength iron castings


PERFORMANCES provided with wide internal paths in order to minimize
(obtained with mineral oil with viscosity of 36 cSt at 50°C)
the flow pressure drop. Wet armature solenoids
CC CA with interchangeable coils are used (for further
Maximum operating pressure: information on solenoids see par. 7).
- P - A - B ports bar 350
- T port 210 160 — The valve is available with DC or AC solenoids.
DC solenoids can also be fed with AC power supply,
Maximum flowrate l/min 100 by using connectors with a built-in rectifier bridge
(see paragraphs 6.4 and 7.2).
Pressure drops ∆p-Q see paragraph 4
— The DC valve is also available in a soft-shifting
Operating limits see paragraph 6 version (see par. 14).
— The DC valve is also available with zinc-nickel
Electrical features see paragraph 7
coating that ensures a salt spray resistance up to
Electrical connections see paragraph 11 600 hours .

Ambient temperature range °C -20 / +50 — It is available a version with UL certified 24V DC
coils for Canada and the United States.
Fluid temperature range °C -20 / +80 (see par. 15).

Fluid viscosity range cSt 10 ÷ 400 — Alternative to the standard manual override there
are lever, push, knob, push and twist, boot and
according to ISO 4406:1999 mechanical detent devices.
Fluid contamination degree
class 20/18/15

Recommended viscosity cSt 25

Mass: single solenoid valve 1,5 1,4


kg
double solenoid valve 2 2

41 150/417 ED 1/18
DS3
1 - IDENTIFICATION CODE

D S 3 - / 11 - /
Directional valve, Option:
solenoid operated
/ W7 = Zinc-nickel surface
treatment (see NOTE 2)
Omit if not required
ISO 4401-03 size

Manual override:
Spool type (see paragraph 3)
omit for override integrated in the tube
S* RSA* TA RK (standard)
SA* RSB* TB CM = manual override, boot protected
SB* TA*
TB* CH = lever manual override
(only for DC version)
The device is not available for TB, TB*
Series: and RSB* spools.
(the overall and mounting dimensions remain RSA* spools: available only for RSA1
unchanged from 10 to 19) and RSA2.
CP = push manual override
(only for DC version)
Seals:
N = NBR seals for mineral oil (standard) CK1 = turning knob override
V = FPM seals for special fluids (only for DC version)
CK2 = push and twist knob override
(only for DC version)
DC power supply CPK = push manual override with
D12 = 12 V mechanical retention
D14 = 14 V (only for DC version)
D24 = 24 V
D28 = 28 V
D48 = 48 V
D110 = 110 V Coil electrical connection
D125 = 125 V (see par. 11):
D220 = 220 V K1 = plug for connector type
D00 = valve without coils (see NOTE 1) EN 175301-803 (ex DIN 43650) (standard)
K2 = plug for connector type AMP JUNIOR
AC power supply (available on D12 and D24 coils only)
A24 = 24 V - 50 Hz K7 = plug DEUTSCH DT04-2P for male
A48 = 48 V - 50 Hz connector type DEUTSCH DT06-2S
A100 = 100 V - 50 Hz / 100 V - 60 Hz (available on D12 and D24 coils only)
A110 = 110 V - 50 Hz / 120 V - 60 Hz
A230 = 230 V - 50 Hz / 240 V - 60 Hz
A00 = valve without coils (see NOTE1)
F110 = 110 V - 60 Hz
F220 = 220 V - 60 Hz

NOTE 1: Coils locking ring and related OR are


supplied together with valves.

NOTE 2: The standard valve is supplied with surface treatment of phosphating black.
The zinc-nickel finishing on the valve body makes the valve suitable to ensure a salt spray resistance up to 240 hours.
For a salt spray resistance up to 600 hours refer to paragraph 17.
(test operated according to UNI EN ISO 9227 standards and test evaluation operated according to UNI EN ISO 10289 standards).

2 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals (code N). For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other fluid types such as HFA, HFB, HFC, please consult our technical department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics. The fluid must be
preserved in its physical and chemical characteristics.

41 150/417 ED 2/18
DS3
3 - SPOOL TYPE

Type S*: Type SA*: Type SB*:


2 solenoids - 3 positions 1 solenoid side A 1 solenoid side B
with spring centering 2 positions (central + external) 2 positions (central + external)
with spring centering with spring centering

Type RSA*: Type RSB*:


1 solenoid side A 1 solenoid side B
2 positions (external + central) 2 positions (external + central)
with return spring with return spring

Type TA: Type TB:


1 solenoid side A 1 solenoid side B
2 external positions 2 external positions
with return spring with return spring

Type RK:
2 solenoids - 2 positions
with mechanical retention

Type TA*: Type TB*:


1 solenoid side A 1 solenoid side B
2 positions with return spring 2 positions with return spring

Besides the diagrams shown, which are the most frequently used, other special versions are available: consult our technical department
for their identification, feasibility and operating limits.

41 150/417 ED 3/18
DS3
4 - PRESSURE DROPS ∆p-Q
(obtained with viscosity 36 cSt at 50 °C)
ENERGIZED POSITION 
p FLOW DIRECTION
SPOOL TYPE P→A P→B A→T B→T
[bar]
6 5 4 3 2
25 CURVES ON GRAPH
1 S1, SA1, SB1 2 2 3 3
20 S2, SA2, SB2 1 1 3 3
S3, SA3, SB3, RSA3, RSB3 3 3 1 1
S4, SA4, SB4, RSA4, RSB4 5 5 5 5
15

S5 2 1 3 3
S6 2 2 3 1
10

S7, S8 4 5 5 5
S9 2 2 3 3
5

S10 1 3 1 3
0 20 40 60 80 100 S11 2 2 1 3
Q [l/min] S12, S17, S19 2 2 3 3
S18 1 2 3 3
S20, S22 1 5 2
S21, S23 5 1 2
S28 6 5 - 6
S29 5 6 6 -
TA, TB 3 3 3 3
TA02, TB02 2 2 2 2
TA23, TB23 3 3
RK, RK02, RK1, 1RK 2 2 2 2

For pressure drops between A and B lines of spools S10, S20,


S21, S22 and S23, which are used in the regenerative diagram,
refer to curve 5.

DE-ENERGIZED POSITION

FLOW DIRECTION
SPOOL TYPE P→A P→B A→T B→T P→T
CURVES ON GRAPH
S2, SA2, SB2 2
S3, SA3, SB3, RSA3, RSB3 3 3
S4, SA4, SB4, RSA4, RSB4 3
S5 4
S6 3
S7, S8 6 6 3
S10 3 3
S11 3
S18 4
S22, S23 3 3
S28, S29 6

5 - SWITCHING TIMES TIMES [ms]


SPOOL TYPE
The values indicated are obtained according to ISO 6403 standard, ENERGIZING DE-ENERGIZING
with mineral oil viscosity 36 cSt at 50°C.
CC 25 ÷ 75 15 ÷ 25
CA 10 ÷ 25 15 ÷ 40

41 150/417 ED 4/18
DS3
6 - OPERATING LIMITS
The curves define the flow rate operating fields according to the valve pressure of the different versions. The values have been obtained
according to ISO 6403 norm with solenoids at rated temperature and supplied with voltage equal to 90% of the nominal voltage. The value
have been obtained with mineral oil, viscosity 36 cSt, temperature 50 °C and filtration according to ISO 4406:1999 class 18/16/13.
The limits for TA02 and TA spools refer to the 4-way operation. The operating limits of a 4-way valve in 3-way operation or with port A or B
plugged or without flow are shown in the chart on the next page. The performance of the DC solenoid powered by AC with rectifier connectors
are at par. 6.4. The performances of the soft-shift valve are shown at par. 14.

6.1 - Valves in standard operation

DC SOLENOID VALVE AC SOLENOID VALVE


DC SOLENOID VALVE
CURVE CURVE
SPOOL SPOOL
P→A P→B P→A P→B
S1,SA1,SB1 1 1 S1,SA1,SB1 1 1
S2, SA2, SB2 2 2 S2, SA2, SB2 2 2
S3, SA3, SB3 3 3 S3, SA3, SB3 3 3
S4, SA4, SB4 4 4 S4, SA4, SB4 2 2
S5 5 5 S5 5 5
S6 4 6 S6 6 6
S7 4 4 S7 4 4
S8 4 4 S8 4 4
S9 7 7 S9 7 7
S10 7 7 S10 8 8
S11 4 6 S11 6 6
S12 1 1 S12 2 2
S17 4 4 S17 7 7
AC SOLENOID VALVE S18 5 5 S18 5 5
S19 4 4 S19 7 7
S20 6* 6 S20 10* 10
S21 6 6* S21 10 10*
S22 6 6 S22 10* 10
S23 6 6 S23 10 11*
S28 9* 9* S28
S29 9* 9* S29
TA, TB 7 7 TA, TB 1 1
TA02, TB02 8 8 TA02, TB02 1 1
TA23, TB23 2 2 TA23, TB23 2 2
TA 30 1 - TA 30 5 -
RK 7 7 RK 8 8
RK02 8 8 RK02 9 9
RK1, 1RK 7 7 RK1, 1RK 8 8

RSA* SPOOLS AC AND DC * Performance obtained for a valve with A and B lines connected
the one to the piston-side chamber and the other to the rod-side
chamber of a double-acting cylinder with area ratio 2:1.

SPOOL CURVE
RSA1 12
RSA2 13
RSA3 14
RSA4 15

41 150/417 ED 5/18
DS3
6.2 - 4-way valve in 3-way operation
Operating limits of a 4-way valve in 3-way operation or with port A or B plugged or without flow.

DC VALVE AC VALVE

CURVE
SPOOL
DC AC
TA backpr. A
1 1
TB backpr. B
TA02 backpr. A
1 1
TB02 backpr. B
TA backpr. B
2 1
TB backpr. A
TA02 backpr. B
3 3
TB02 backpr. A

6.3 - AC solenoid valve with coil A110 fed with 110V - 60 Hz

CURVE
SPOOL
P→A P→B
S1,SA1, SB1 1 1
S2, SA2, SB2 2 2
S3, SA3, SB3 3 3
S4, SA4, SB4 4 4
S9 5 5
TA, TB 2 2
RK 6 6

6.4 - Operating limits for DC solenoid valves fed with AC with rectifier connectors

CURVE
SPOOL
P→A P→B
S1, SA1, SB1 2 2
S2, SA2, SB2 3 3
S3, SA3, SB3 4 4
S4, SA4, SB4 2 2
S9 5 5
TA, TB 6 6
RK 1 1

41 150/417 ED 6/18
DS3
7 - ELECTRICAL FEATURES

7.1 - Solenoids
These are essentially made up of two parts: tube and coil. The tube
is threaded into the valve body and includes the armature that SUPPLY VOLTAGE FLUCTUATION ± 10% Vnom
moves immersed in oil, without wear. The inner part, in contact with MAx SWITCH ON FREQUENCY 18.000 ins/hr
the oil in the return line, ensures heat dissipation. The coil is
fastened to the tube by a threaded ring, and can be rotated 360°, to DUTY CYCLE 100%
suit the available space.
ELECTROMAGNETIC In compliance with
COMPATIBILITY (EMC) (NOTE) 2014/30/EU
Protection from atmospheric agents IEC 60529
The IP protection degree is guaranteed only with both valve and In compliance with
LOW VOLTAGE
connectors of an equivalent IP degree, correctly connected and 2014/35/EU
installed.
CLASS OF PROTECTION :
electric whole Coil insulation (VDE 0580) class H
electric connection connection valve Impregnation: DC valve class F
protection protection AC valve class H
K1 EN 175301-803 (ex DIN 43650) IP65
NOTE: In order to further reduce the emissions, with DC supply,
K2 AMP JUNIOR IP65/67 IP65 use of type H connectors is recommended. These prevent voltage
peaks on opening of the coil supply electrical circuit
K7 DEUTSCH DT04 male IP65/67 (see cat. 49 000).

7.2 - Current and absorbed power for DC


solenoid valve
Coils for direct current (values ± 10%)
The table shows current and power consumption
values of the DC coils. Nominal Resistance Current Power Coil code
voltage at 20°C consumpt. consumpt
Using connectors type "D" (see cat. 49 000) with
[V] [Ω] [A] [W] K1 K2 K7
embedded bridge rectifier it is possible to feed DC
coils (starting from 48V voltage) with alternating D12 12 4,4 2,72 32,7 1903080 1903100 1902940
current (50 or 60 Hz), considering a reduction of
the operating limits (see diagram at section 6.4). D14 14 7,2 1.93 27 1903086
D24 24 18,6 1,29 31 1903081 1903101 1902941
D28 28 26 1,11 31 1903082
D48 48 78,6 0,61 29,5 1903083
D110 110 423 0,26 28,2 1903464
D125 125 550 0,23 28,6 1903467
D220 220 1692 0,13 28,2 1903465

7.3 - Current and absorbed power for AC solenoid valve


The table shows current and power consumption values at inrush and at holding, for AC coils.
Coils for alternating current (values ± 5%)
Nominal Freq. Resistance Current Current Power Power
Coil
Voltage at 20°C consumption consumption consumption consumption
Suffix Code
at inrush at holding at inrush at holding
K1
[V] [Hz] [Ω] [A] [A] [VA] [VA]
A24 24 1,69 5,81 1,32 139 32 1902830
50
A48 48 6,02 3,78 0,86 182 41 1902831

100V-50Hz 2,11 0,48 211 48


A100 23,3 1902836
100V-60Hz 1,63 0,37 163 37

110V-50Hz 1,76 0,40 194 44


A110 50/60 33 1902832
120V-60Hz 1,54 0,35 185 42

230V-50Hz 0,92 0,21 213 48


A230 135 1902833
240V-60Hz 0,79 0,18 190 43
F110 110 28,5 1,45 0,33 160 36 1902834
60
F220 220 103 0,92 0,21 203 46 1902835

41 150/417 ED 7/18
DS3
8 - OVERALL AND MOUNTING DIMENSIONS FOR DC SOLENOID VALVES
dimensions in mm
DS3 - S*
DS3 - RK

DS3-SA*, DS3-RSA*
DS3-TA, DS3-TA*

solenoid position for SB* , RSB*, TB and TB* configurations

1 Mounting surface with sealing rings:


4 OR 2037 (9.25x1.78) - 90 shore
2 Standard manual override included in the
solenoid tube
3 Coil (360° revolving)

4 Coil removal space

5 EN 175301-803 (ex DIN 43650) connector


To be ordered separately. See cat. 49 000
Valve fastening: 4 SHC screws ISO 4762 M5x30
Tightening torque: 5 Nm (A8.8) 6 Connector removal space

Threads of mounting holes: M5x10 7 Locking ring: tightening torque 5 ±0.5 Nm

41 150/417 ED 8/18
DS3
9 - OVERALL AND MOUNTING DIMENSIONS FOR AC SOLENOID VALVES
dimensions in mm
DS3 - S*
2 3 DS3 - RK 3 2 5 15
6

87
P 56
47
A B
22.5

1 54 46
47
65 73
211
75

4 11.2
7.5 7
T

A B
P

DS3-SA*, DS3-RSA*
DS3-TA, DS3-TA*

solenoid position for SB*, RSB*, TB and TB* configurations

1 Mounting surface with sealing rings:


4 OR 2037 (9.25x1.78) - 90 shore
2 Standard manual override included in the
solenoid tube
3 Coil (90° revolving)

4 Coil removal space

5 EN 175301-803 (ex DIN 43650) connector


To be ordered separately. See cat. 49 000
Valve fastening: 4 SHC screws ISO 4762 M5x30
Tightening torque: 5 Nm (A8.8) 6 Connector removal space

Threads of mounting holes: M5x10 7 Locking ring: tightening torque 5 ±0.5 Nm

41 150/417 ED 9/18
DS3
10 - INSTALLATION
Configurations with centering and return springs can be mounted in any position; type RK valves - Surface
Qualità finishing
della superficie
without springs and with mechanical detent - must be mounted with the longitudinal axis horizontal.
Valve fixing takes place by means of screws or tie rods, with the valve mounted on a lapped surface,
0.01/100
with values of planarity and smoothness that are equal to or better than those indicated in the drawing.
If the minimum values of planarity and/or smoothness are not met, fluid leakages between valve and
0.8
mounting surface can easily occur.

11 - ELECTRIC CONNECTIONS

connection for EN 175301-803


(ex DIN 43650) connector
code K1 (standard)
code WK1 (W7 version only)

valve height
connection for AMP JUNIOR
connector
code K2
valve height

connection for
DEUTSCH DT06-2S male connector
code K7

connection for
valve height

DEUTSCH DT06-2S male connector


code WK7 (W7 version only)
code WK7D (W7 version only - coil
with diode)

12 - ELECTRIC CONNECTORS
Solenoid operated valves are delivered without connectors. Connectors type EN 175301-803 (ex DIN 43650) for K1 connections can be
ordered separately. See catalogue 49 000.

41 150/417 ED 10/18
DS3
13 - MANUAL OVERRIDES

13.1 - Manual override, boot protected


CM-DS3/11 - Version for DC solenoid valve Version for AC solenoid valve

Code: 3401150006 Code: 0269201

13.2 - CH-DS3/11 Lever manual override (only for DC solenoid valve)

110

P
A
NOTE: The lever device is always
located in the A side of the valve.
The high resistance to corrosion
52 (SB version) 27.5
118 50.5 valves (par. 17) are equipped with a
142 (coils WK1 and WK7D only) boot for solenoid tube protection.

13.3 - CP-DS3/10 Push manual override 13.4 - CK1-DS3/11 knob manual override, turning
(only for DC solenoid valve) (only for DC solenoid valve)

Code: 3401150005 Code: 3401150015

13.5 - CPK-DS3/10 Push manual override with mechanical 13.6 - CK2-DS3/10 Push and twist manual override
retention (only for DC solenoid valve) (only for DC solenoid valve)

Code: 3401150004 Code: 3401150016

41 150/417 ED 11/18
DS3
14 - SOFT-SHIFT VERSION FOR DC VALVE

14.1 - Identification code

D S 3 - / 13 - / F
Solenoid operated directional Option:
control valve / W7 = see par. 1

ISO 4401-03 size

Spool type
The hydraulic symbols of S2F and S4F are identical to
those of S2 and S4 spools (p.2) Manual override
S1 TA12 (see par.1 and 13)
S2F TB12
S4F TA23 Soft-shifting
S9 TB23
S12 Coil electrical connection
(see par. 11):
Series: K1 = plug for connector type
(the overall and mounting dimensions remain unchanged EN 175301-803 (ex DIN 43650) (standard)
from 10 to 19) K2 = plug for connector type AMP JUNIOR
(available on D12 and D24 coils only)
Seals:
K7 = plug DEUTSCH DT04-2P for male
N = NBR seals for mineral oil (standard) connector type DEUTSCH DT06-2S
V = FPM seals for special fluids (available on D12 and D24 coils only)

DC power supply
D12 = 12 V
D24 = 24 V
D28 = 28 V
D110 = 110 V
D220 = 220 V

This version enables hydraulic actuators to perform a smooth start


and stop by reducing the speed of movement of the valve spool.
In this version, the S9 spool must be used instead of the S3 type.
The diagram on the side shows the operating limits of the spools
available in the soft-shifting version, while the table shows the
switching times.
The values indicated are obtained according to ISO 6403 standard,
with mineral oil viscosity 36 cSt at 50°C.
The shifting time and characteristics curves are influenced by the
viscosity (and thus by the temperature) of the operating fluid.
Moreover, times can vary according to the flow rate and operating
pressure values of the valve.
For correct operation of the soft-shifting ensure the solenoid tubes
are always filled with oil. At this matter, we recommend to install a
backpressure valve set at 1 ÷ 2 bar on T line.

TIMES [ms]
SPOOL CURVE
ENERGIZING DE-ENERGIZING
S1, S12 1 350 200 ÷ 300
S2F 2 400 100 ÷ 250
S4F 4 350 150 ÷ 300
S9 1 400 200 ÷ 300
TA12, TB12 3 180 200 ÷ 300
TA23, TB23 300 200 ÷ 300

41 150/417 ED 12/18
DS3
15 - VERSION WITH UL CERTIFIED COILS
15.1 - Identification code

D S 3 - / 11 - D24 UL K1 /
Solenoid operated directional Manual override:
control valve omit for override integrated
in the tube (standard)
ISO 4401-03 size CM = manual override, boot
protected
Spool type
See paragraph 3 Coil electrical connection
for connector type EN 175301-803
Series: (ex DIN 43650)
(the overall and mounting dimensions remain
unchanged from 10 to 19) LISK coil, UL certified
to United States and Canada. Class 155 (F)
Seals:
N = NBR seals for mineral oil (standard)
V = FPM seals for special fluids Power supply DC 24 V

15.2 - UL file number 15.3 - Electrical features


The UL database website provides informations about the (values ± 10%)
certification, by entering the code MH29222 in the 'UL file
number' field. Nominal Resistance Current Power
Coil code
voltage at 20°C consumpt. consumpt
[V] [Ω] [A] [W]
D24ULK1 24 19.2 1.25 30 1903341

NOTE: Valves with UL coils must be ordered complete. The UL coils are
not interchangeable with those of standard valves.

15.4 - Overall and mounting dimensions 

dimensions in mm

Valve fastening: 4 SHC screws ISO 4762 M5x30 1 Standard manual override included in the
solenoid tube
Tightening torque: 5 Nm (A8.8)
2 CM version:
Threads of mounting holes: M5x10 boot manual ovverride, rubber

41 150/417 ED 13/18
DS3
16 - VERSION WITH FIxING INTERCHANGEABLE WITH 4WE6*6x RExROTH

16.1 - Identification code

D S 3 R - / 11 - /
Directional valve,
solenoid operated Complete the indentification code
configuration as for in paragraph 1.

ISO 4401-03 size Series:


(the overall and mounting dimensions remain unchanged from
10 to 19)
Fastening screws interchangeable
with Rexroth 4WE6*6X valve.

Spool type (see paragraph 3)


S* RSA* TA RK
SA* RSB* TB
SB* TA*
TB*

16.2 - Overall and mounting dimensions for DC solenoid valves

dimensions in mm

Please refer to the standard valve at


paragraph 8 for non-quoted dimensions.

Valve fastening: 4 SHC screws ISO 4762 M5x50


Tightening torque: 5 Nm (A8.8)
Threads of mounting holes: M5x10

16.3 - Overall and mounting dimensions for AC solenoid valves

dimensions in mm

Please refer to the standard valve at


paragraph 9 for non-quoted dimensions.

Valve fastening: 4 SHC screws ISO 4762 M5x50


Tightening torque: 5 Nm (A8.8)
Threads of mounting holes: M5x10

41 150/417 ED 14/18
DS3
17 - HIGH IP AND CORROSION RESISTANCE VERSION
17.1 - Identification code

D S 3 - / - / / W7
Solenoid operated directional Manual override:
control valve CM = manual override, boot protected
(standard)
CH = lever manual override
ISO 4401-03 size CP = push manual override
CK1 = turning knob override
CK2 = push and twist knob
Spool type (only for DC version)
See paragraph 3 or 14. CPK = push manual override with
mechanical retention
Series: (See paragraph 1 or 14) Coil electrical connection
(the overall and mounting dimensions remain WK1 = plug for connector type EN 175301-803
unchanged from 10 to 19) (ex DIN 43650)
WK7 = plug DEUTSCH DT04-2P, for male
Seals: connector type DEUTSCH DT06-2S.
N = NBR seals for mineral oil (standard) WK7D = plug DEUTSCH DT04-2P, for male
V = FPM seals for special fluids connector type DEUTSCH DT06-2S.
Coil with diode.
DC power supply
D12 = 12 V
D24 = 24 V

17.2 - Corrosion resistance


This version features the zinc-nickel coating on all exposed metal parts of the valve,
making it resistant to exposure to the salt spray for 600 hours (test performed according
to UNI EN ISO 9227 and assessment test performed according to UNI EN ISO 10289).

17.3 - DC coils
The coils feature a zinc-nickel surface treatment.
The WK7D coil includes a suppressor diode of pulses for protection from voltage peaks
during switching. During the switching the diode significantly reduces the energy
released by the winding, by limiting the voltage to 31.4V in the D12 coil and to 58.9 V in
the D24 coil.

(values ±10%)

Nominal Resistance Current Power Coil code


voltage at 20°C consumpt. consumpt
[V] [Ω] [A] [W] WK1 WK7 WK7D

D12 12 4,4 2,72 32,7 1903590 1903580 1903600


D24 24 18,6 1,29 31 1903591 1903581 1903601

17.4 - Protection from atmospheric agents IEC 60529


NOTE: As regards the liquid ingress protection
The IP protection degree is guaranteed only with both valve and connectors of an
(second digit), there are three means of
equivalent IP degree, correctly connected and installed.
protection.
Codes from 1 to 6 are related to water jets.
electric connection whole valve
electric connection Rates 7 and 8 are related to immersion.
protection protection
Rate 9 is reserved for high pressure and
WK1 EN 175301-803 (ex DIN 43650) IP66 IP66 temperature water jets.
IP66/IP68/IP69 IP66/IP68/IP69 This means that IPX6 covers all the lower steps,
WK7 DEUTSCH DT04 male rate IPX8 covers IPX7 but not IPX6 and lower,
IP69K* IP69K*
instead IPX9 does not cover any of them.
IP66/IP68/IP69 IP66/IP68/IP69
WK7D DEUTSCH DT04 male Whether a device meets two types of protection
IP69K* IP69K*
requirements it must be indicated by listing both
(*) The IP69K protection degree is not taken into account in IEC 60529 but it is included the tests separated by a slash.
in ISO 20653. (E.g. a marking of an equipment covered both
by temporary immersion and water jets is
IP66/IP68).

41 150/417 ED 15/18
DS3
18 - PORT RESTRICTORS
Port restrictors are recommended if flow
variations which exceed the valve performance Ø (mm) part number Ø (mm) part number
limit during the switching processes occur, or for blank 0144162 1.2 0144035
circuit dampening.
0.6 0144163 1.5 0144036
Port restrictor plugs can be ordered separately
0.8 0144033 1.8 0144164
with the part numbers shown at left.
1 0144034 2 0144165

19 - SPARE PARTS FOR DC SOLENOID VALVE

DC COILS AND ELECTRICAL CONNECTORS


IDENTIFICATION CODE

C 22S3 - /
Supply voltage Series no.:
D12 = 12 V 10 = for K7 and WK7
D14 = 14 V 11 = for K1 up to D48 and K2 1 Coil locking ring with seal included cod. 0119412
D24 = 24 V 12 = for K1 D110, D125, D220, Tightening torque 5 ±0.5 Nm
D28 = 28 V WK1 and WK7D
D48 = 48 V 2 ORM type 0220-20 (22x2) - 70 Shore
D125 = 125 V
Coil electrical connection (see par. 11): 3 Coil (see identification code)
D110 = 110 V
D220 = 220 V K1 = plug for connector type 4 Solenoid tube for standard version:
EN 175301-803 (ex DIN 43650)
TD22-DS3/10N (NBR seals)
D12 and D24 coils only: TD22-DS3/10V (FPM seals)
K2 = plug for connector AMP JUNIOR Solenoid tube for version with soft-shifting:
K7 = plug DEUTSCH DT04-2P for male TD22-DS3F/10N (NBR seals)
connector DEUTSCH DT06-2S TD22-DS3F/10V (FPM seals)
WK1 = plug for connector type NOTE: OR n°5 included
EN 175301-803 (ex DIN 43650)
WK7 = plug DEUTSCH DT04-2P, for male 5 OR type 2062 (15.6x1.78) - 70 Shore
connector type DEUTSCH DT06-2S
6 4 OR type 2037 (9.25x1.78) - 90 Shore
WK7D = plug DEUTSCH DT04-2P, for male
connector type DEUTSCH DT06-2S.
Coil with diode SEALS KIT
The codes include the O-Ring n° 2, 5 and 6.
Cod. 1985406 NBR seals
NOTE: You can also order coils using the coil codes Cod. 1985410 FPM (viton) seals
in paragraphs 7.2 and 17.3.

41 150/417 ED 16/18
DS3
20 - SPARE PARTS FOR AC SOLENOID VALVE

5 4

2
3
AC COILS IDENTIFICATION CODE

C 20.6S3 - K1 / 10
1

Series no.:
Supply voltage (the overall and
A24 = 24 V - 50 Hz mounting dimensions 1 Coil locking ring cod. 0119333
A48 = 48 V - 50 Hz remain unchanged Tightening torque 5 ±0.5 Nm
A100 = 100 V - 50 Hz from 10 to 19)
2 Snap ring cod. 0550483
100 V - 60 Hz
A110 = 110 V - 50 Hz 3 Coil (see identification code on the side)
120 V - 60 Hz Plug for connector type
A230 = 230 V - 50 Hz EN 175301-803 4 Solenoid tube :
240 V - 60 Hz (ex DIN 43650)
TA20.6-DS3/10N (NBR seals)
F110 = 110 V - 60 Hz TA20.6-DS3/10V (FPM seals)
F220 = 220 V - 60 Hz NOTE: OR n° 5 included
5 OR type 2062 (15.6x1.78) - 70 Shore
6 N. 4 OR type 2037 (9.25x1.78) - 90 Shore

SEALS KIT
The codes include the OR nr. 5 and 6.
Cod. 1985406 NBR seals
NOTE: You can also order coils using the coil codes in paragraph 7.3 Cod. 1985410 FPM (viton) seals

21 - SUBPLATES
(see catalogue 51 000)

Type PMMD-AI3G with rear ports 3/8” BSP


Type PMMD-AL3G with side ports 3/8” BSP

41 150/417 ED 17/18
DS3

41 150/417 ED REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS. 18/18

You might also like