Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Dse3G: Series 31 Subplate Mounting ISO 4401-03 P Max

Download as pdf or txt
Download as pdf or txt
You are on page 1of 10

83 220/317 ED

DSE3G
DIRECTIONAL VALVE
WITH PROPORTIONAL CONTROL
AND INTEGRATED
ELECTRONICS
SERIES 31
SUBPLATE MOUNTING
ISO 4401-03

p max 350 bar


Q max 40 l/min

MOUNTING INTERFACE OPERATING PRINCIPLE

ISO 4401-03-02-0-05 40.5


(CETOP 4.2-4-03-350)
33

30.2

21.5

12.7

5.1 0.75

T
15.5
31 25.9 A B
31.75

— The DSE3G is a direct operated directional valve with


integrated electric proportional control and a mounting
P
interface compliant with ISO 4401-03 standards.
— It is used to control the positioning and the speed of
ø 7.5 (max)
ø4 hydraulic actuators.
M5 — The valves are available with command signal in voltage
or current and on-board electronics with internal enable,
PERFORMANCES external enable or 0V monitor on pin C.
(obtained with mineral oil with viscosity of 36 cSt at 50°C and p = 140 bar) — A signal that monitors the current to the
solenoid is available on pin F.
Max operating pressure:
- P - A - B ports bar 350 — The valve is easy to install. The driver
- T port 210 manages digital settings directly.

Nominal flow with ∆p 10 bar P-T l/min 1 - 4 - 8 - 16 - 26


Response times see paragraph 7
HYDRAULIC SYMBOLS (typical)
Hysteresis % of Q max < 3%
Repeatability % of Q max < ±1%
Electrical characteristics see paragraph 3
Ambient temperature range °C -20 / +60
Fluid temperature range °C -20 / +80
Fluid viscosity range cSt 10 ÷ 400
according to ISO 4406:1999
Fluid contamination degree
class 18/16/13
Recommended viscosity cSt 25
Mass: single solenoid valve 1,9
kg
double solenoid valve 2,4

83 220/317 ED 1/10
DSE3G SERIES 31

1 - IDENTIFICATION CODE

D S E 3 G - / 31 - K11 /
Direct operated Option:
directional control manual override
valve (see paragraph 8)

Electric proportional Pin C function:


control A = external enable
B = internal enable
Size ISO 4401-03
C = 0V monitor
Digital integrated electronics
Main connector 6 pin + PE
for open loop

Spool type: Reference signal:


C = closed centres E0 = voltage ±10 V
A = open centres E1 = current 4 ÷ 20 mA
CZ = with overlap jump
Seals:
Nominal flow rate of the spool N = NBR seals for mineral oil (standard)
(see chart par. 2) V = FPM seals for special fluids

Solenoid position (omit for 2 solenoids configuration): Series No.


SA = 1 solenoid on side A (the overall and mounting dimensions remain unchanged
from 30 to 39)

2 - CONFIGURATIONS

Valve configuration depends on the combination of the following elements:


number of proportional solenoids, spool type, rated flow.

Configuration 2 solenoids : Configuration 1 solenoid on side A “SA”:


3 positions with spring centering 2 positions (central + external)
with spring centering

* Controlled flow with ∆p10 bar P-T


04 4 l/min
08 8 l/min
16 16 l/min
16/08 16 (P-A) / 08 (B -T) l/min
26 26 l/min
26/13 26 (P-A) / 13 (B -T) l/min

* Controlled flow with ∆p10 bar P-T


01R 1 l/min

83 220/317 ED 2/10
DSE3G SERIES 31

3 - ELECTRICAL CHARACTERISTICS

3.1 - Electrical on board electronics


Duty cycle 100% (continuous operation)

Protection class according to EN 60529 IP65 / IP67

Supply voltage V DC 24 (from 19 to 30 VDC), ripple max 3 Vpp

Power consumption VA 25

Maximum solenoid current A 1.88

Fuse protection, external 3A

Command signals: voltage (E0) V DC ±10 (Impedance Ri > 11 kOhm)


current (E1) mA 4 ÷ 20 (Impedance Ri = 58 Ohm)

Monitor signal (current to solenoid):


voltage (E0) V DC ±10 (Impedance Ro > 1 kOhm)
current (E1) mA 4 ÷ 20 (Impedance Ro = 500 Ohm)

Overload and electronics overheating, cable breakdown,


Managed breakdowns
supply voltage failures

Communication LIN-bus Interface (with the optional kit)


Connection 7 - pin MIL-C-5015-G (DIN-EN 175201-804)
Electromagnetic compatibility (EMC)
emissions EN 61000-6-4 According to 2014/30/EU standards
immunity EN 61000-6-2

3.2 - On-board electronics diagrams

VERSION A - External Enable VERSION B - Internal Enable

VERSION C - 0V Monitor

83 220/317 ED 3/10
DSE3G SERIES 31

4 - VERSIONS WITH VOLTAGE COMMAND (E0)


The reference signal is between -10V and +10V on double solenoid valve, and 0 ÷ 10V on single solenoid valve SA. The monitor feature of
versions B anc C becomes available with a delay of 0,5 sec from the power-on of the card.

COMMAND -10V 0V +10V COMMAND +10V 0V


MONITOR -10V 0V +10V MONITOR +10V 0V

Pin Values version A version B version C

A 24 V DC
Supply Voltage
B 0 V
Enable not used PIN F reference
C
24 V DC - 0V
D ± 10 V Command (differential input)

E 0 V PIN D reference

F ± 10 V Monitor (0V reference: pin B) Monitor

PE GND Ground (Earth)

5 - VERSIONS WITH CURRENT COMMAND (E1)


The reference signal is supplied in current 4 ÷ 20 mA. If the current for command is lower, the card shows a breakdown cable error. To reset
the error is sufficient restoring the signal.
The monitor feature of versions B anc C becomes available with a delay of 0,5 sec from the power-on of the card.

COMMAND 4 mA 12 mA 20 mA COMMAND 20 mA 4 mA
MONITOR 4 mA 12 mA 20 mA MONITOR 20 mA 4 mA

Pin Values version A version B version C

A 24 V DC
Supply Voltage
B 0 V
Enable not used PIN F reference
C
24 V DC - 0V
D 4 ÷ 20 mA Command

E 0 V PIN D reference

F 4 ÷ 20 mA Monitor (0V reference: pin B) Monitor

PE GND Ground (Earth)

83 220/317 ED 4/10
DSE3G
SERIES 31

6 - CHARACTERISTIC CURVES
(obtained with mineral oil with viscosity of 36 cSt at 50°C and p = 140 bar)

Typical flow rate curves at constant ∆p related to the reference signal and measured for the
available spools. The ∆p values are measured between P and T valve ports.
The curves are obtained after linearization in factory of the characteristic curve through the digital
amplifier. The linearization of the curve is performed with a constant ∆p of 5 bar and by setting the
value of flow start at 20% of the reference signal.
NOTE: for the zero overlap spool (CZ), please refer to the characteristic curves of C type spool,
considering that the starting flow rate value is approx. 150 mV.

SPOOL TYPE C01R

SPOOL TYPE C04

SPOOL TYPE C08

83 220/317 ED 5/10
DSE3G
SERIES 31

SPOOL TYPE C16

SPOOL TYPE C26

SPOOL TYPE A04

83 220/317 ED 6/10
DSE3G
SERIES 31

SPOOL TYPE A08

SPOOL TYPE A16

SPOOL TYPE A26

83 220/317 ED 7/10
DSE3G SERIES 31

7 - RESPONSE TIMES
(obtained with mineral oil with viscosity of 36 cSt at 50°C and p = 140 bar)

8 - MANUAL OVERRIDE
The standard valve has solenoids whose pin for the manual operation is integrated in the tube. The actuation of this override must be executed
with a suitable tool, minding not to damage the sliding surface.
Two versions are available upon request:
- CM version, manual override boot protected.
- CS version, with metal locking ring provided with an M4 screw and lock nut to allow the continuous and adjustable mechanical operation.

CM Version CS Version

6.4 max stroke

Code: 3803210003 Code: 3803210004

83 220/317 ED 8/10
DSE3G SERIES 31

9 - OVERALL AND MOUNTING DIMENSIONS

DSE3G-A* dimensions in mm
DSE3G-C*
DSE3G-CZ*

DSE3G-A* SA
DSE3G-C* SA

1 Mounting surface with sealing rings:


N. 4 OR type 2037 (9.25x1.78) 90 Shore

2 Coil removal space (solenoid B only)

3 Standard manual override


embedded in the solenoid tube

Fastening bolts: 4 bolts M5x30 - ISO 4762 4 Main connection

Torque: 5 Nm (A8.8) 5 Mating connector.


To be ordered separately.
Threads of mounting holes: M5x10 See paragraph 12

83 220/317 ED 9/10
DSE3G
SERIES 31

10 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.

11 - INSTALLATION
DSE3G valves can be installed in any position without impairing Surface finishing
correct operation.
Ensure that there is no air in the hydraulic circuit.
Valves are fixed by means of screws or tie rods on a flat surface
with planarity and roughness equal to or better than those indicated
in the relative symbols. If minimum values are not observed, fluid
can easily leak between the valve and support surface.

12 - ACCESSORIES
(to be ordered separately)

12.1 - Mating connector


These valves have a plug for 7-pin mating connector, that is placed on the box of the
integral motion control.
So as to avoid electromagnetic troubles and comply with the electromagnetic
compatibility regulation EMC, it is recommended the use of a metal
connector.
If a plastic connector is used, make sure that the protection characteristics IP and
EMC of the valve are guaranteed.
Duplomatic offers a metal cable connector type MIL-C-5015-G (EN 175201-804).
name: EX7S/L/10 code 3890000003

12.2 - Connection cables size


Power supply:
- up to 20 m cable lenght : 1,0 mm2
- up to 40 m cable lenght : 1,5 mm2
Signal: 0,50 mm2
A suitable cable would have 7 isolated conductors, a separate screen for the signal wires and an overall screen.
12.3 - Kit for start-up LINPC-USB
Device for service start-up and diagnostic, see catalogue 89850.

13 - SUBPLATES
(see catalogue 51 000)

PMMD-AI3G rear ports

PMMD-AL3G side ports

Ports dimensions: P, T, A, B: 3/8” BSP

83 220/317 ED REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS. 10/10