Dse3G: Series 31 Subplate Mounting ISO 4401-03 P Max
Dse3G: Series 31 Subplate Mounting ISO 4401-03 P Max
Dse3G: Series 31 Subplate Mounting ISO 4401-03 P Max
DSE3G
DIRECTIONAL VALVE
WITH PROPORTIONAL CONTROL
AND INTEGRATED
ELECTRONICS
SERIES 31
SUBPLATE MOUNTING
ISO 4401-03
30.2
21.5
12.7
5.1 0.75
T
15.5
31 25.9 A B
31.75
83 220/317 ED 1/10
DSE3G SERIES 31
1 - IDENTIFICATION CODE
D S E 3 G - / 31 - K11 /
Direct operated Option:
directional control manual override
valve (see paragraph 8)
2 - CONFIGURATIONS
83 220/317 ED 2/10
DSE3G SERIES 31
3 - ELECTRICAL CHARACTERISTICS
Power consumption VA 25
VERSION C - 0V Monitor
83 220/317 ED 3/10
DSE3G SERIES 31
A 24 V DC
Supply Voltage
B 0 V
Enable not used PIN F reference
C
24 V DC - 0V
D ± 10 V Command (differential input)
COMMAND 4 mA 12 mA 20 mA COMMAND 20 mA 4 mA
MONITOR 4 mA 12 mA 20 mA MONITOR 20 mA 4 mA
A 24 V DC
Supply Voltage
B 0 V
Enable not used PIN F reference
C
24 V DC - 0V
D 4 ÷ 20 mA Command
83 220/317 ED 4/10
DSE3G
SERIES 31
6 - CHARACTERISTIC CURVES
(obtained with mineral oil with viscosity of 36 cSt at 50°C and p = 140 bar)
Typical flow rate curves at constant ∆p related to the reference signal and measured for the
available spools. The ∆p values are measured between P and T valve ports.
The curves are obtained after linearization in factory of the characteristic curve through the digital
amplifier. The linearization of the curve is performed with a constant ∆p of 5 bar and by setting the
value of flow start at 20% of the reference signal.
NOTE: for the zero overlap spool (CZ), please refer to the characteristic curves of C type spool,
considering that the starting flow rate value is approx. 150 mV.
83 220/317 ED 5/10
DSE3G
SERIES 31
83 220/317 ED 6/10
DSE3G
SERIES 31
83 220/317 ED 7/10
DSE3G SERIES 31
7 - RESPONSE TIMES
(obtained with mineral oil with viscosity of 36 cSt at 50°C and p = 140 bar)
8 - MANUAL OVERRIDE
The standard valve has solenoids whose pin for the manual operation is integrated in the tube. The actuation of this override must be executed
with a suitable tool, minding not to damage the sliding surface.
Two versions are available upon request:
- CM version, manual override boot protected.
- CS version, with metal locking ring provided with an M4 screw and lock nut to allow the continuous and adjustable mechanical operation.
CM Version CS Version
83 220/317 ED 8/10
DSE3G SERIES 31
DSE3G-A* dimensions in mm
DSE3G-C*
DSE3G-CZ*
DSE3G-A* SA
DSE3G-C* SA
83 220/317 ED 9/10
DSE3G
SERIES 31
10 - HYDRAULIC FLUIDS
Use mineral oil-based hydraulic fluids HL or HM type, according to ISO 6743-4. For these fluids, use NBR seals. For fluids HFDR type
(phosphate esters) use FPM seals (code V). For the use of other kinds of fluid such as HFA, HFB, HFC, please consult our technical
department.
Using fluids at temperatures higher than 80 °C causes a faster degradation of the fluid and of the seals characteristics.
The fluid must be preserved in its physical and chemical characteristics.
11 - INSTALLATION
DSE3G valves can be installed in any position without impairing Surface finishing
correct operation.
Ensure that there is no air in the hydraulic circuit.
Valves are fixed by means of screws or tie rods on a flat surface
with planarity and roughness equal to or better than those indicated
in the relative symbols. If minimum values are not observed, fluid
can easily leak between the valve and support surface.
12 - ACCESSORIES
(to be ordered separately)
13 - SUBPLATES
(see catalogue 51 000)
83 220/317 ED REPRODUCTION IS FORBIDDEN. THE COMPANY RESERVES THE RIGHT TO APPLY ANY MODIFICATIONS. 10/10