Flow Divider Designs: Hydraulik
Flow Divider Designs: Hydraulik
Flow Divider Designs: Hydraulik
Edition 28.01
Jahns-Regulatoren GmbH
Flow-divider applications
Synchronised running ....................................................................................................................... 3
Pressure multipliers ............................................................................................................................ 3
Lubricating-oil flow divider ............................................................................................................. 3
Synchronisation differences............................................................................................................ 4
Internal pressure-drop....................................................................................................................... 4
Means of overcoming the pressure-drop................................................................................... 4
Using a “driver”...................................................................................................................................... 5
Compensating synchronisation-errors........................................................................................ 5
Hydraulic fluids .................................................................................................................................... 6
Noise-levels ........................................................................................................................................... 6
Applications limits .............................................................................................................................. 6
Synchronisation ratios....................................................................................................................... 6
Synchronisation errors due to differnt oil-compression ....................................................... 6
Inlet/outlet-blocks ............................................................................................................................. 6
Use of other fluids than mineraloil................................................................................................ 6
How to install the flow divider, start-up ...................................................................................... 7
Integral pressure valves .................................................................................................................... 8
Installation instructions, Commissioning ................................................................................... 9
Page 2 www.jahns-hydraulik.de
HYDRAULIK
Flow-divider application
Pressure multipliers
As mentioned earlier as well as operating as a synchro- Lubricating-oil flow-divider
nising instrument the flow divider can be utilised as Shafts with multiple sets of friction bearings require
a pressure multiplier. The entire range of gear-motor a sure supply of lubrificating oil in equal quantities to
flow dividers can be used for this type of application each of the bearings.With the gear-motor flow dividers,
and due their low internal pressure losses and low cost that do not have any external leakages, if the gear of
they often represent the optimal solution. one of the sections are turning then a synchronised
The cast-iron MTO range should be used when it is flow in all the other sections is ensured. It is therefore
necessary to increase the output pressure to values only necessary to check the speed of on of the shafts
around 280 bar. There is the option of requesting special with anelectronic sensor and Jahns can be supply the
versions with individual sections having varying absorp- component required for this solution.
tion volumes. This enables pressures to be increased
by a factor of three, four and more.
www.jahns-hydraulik.de Page 3
HYDRAULIK
Flow-divider application
Synchronisation differences If it is important for you to know the actual value, please
enquire providing details as regards the respective
With particular reference to the gear-motor flow divi-
pressure, oil flow-rate and oil viscosity.
ders MTO but also for the radial-motor flow dividers
MT-GM and MTL synchronisation differences depend Internal pressure drop in
on the following parameters:
radial-piston flow-dividers
• Oil viscosity and temperature
The radial piston motor design has larger pressure drops
• Pressure load varability than the gear motor design and the pressure drop also
• System pressure levels depend on the outlet pressure. The following of the
outlet pressure for all MT-GM an MTL models:
• Total flow rate to be divided
Precise indications of synchronisation levels are only
possible if the details of all the above parameters are Required Input Pressure
known. output pressure pressure drop
A general indication may be obtained from the follo- (bar) (bar) (bar)
wing values:
MK under maximum oil-flow-values in the catalogue 50 60 10
synchronisation tollerances ± 4,0 up to ± 5,0 %
100 120 20
MTO Size 0 (aluminium housing)
140 175 35
synchronisation tollerances ± 2,0 up to ± 3,0 %
150 190 40
MTO Size 1 and 2 (aluminium housing)
running more than 1200 rpm 180 225 45
synchronisation tollerances ± 1,5 up to ± 2,0 % 190 240 50
MTO Size 3 and 4 (cast iron housing) 210 265 55
synchronisation tollerances ± 3 up to ± 4 %
230 285 55
HTO synchronisation tollerances ± 3 up to ± 4 %
Pressure drop in radial-piston flow-dividers MT-GM and MTL
MT-GM synchronisation tollerances ± 0,5 up to ± 0,8 %
MTL synchronisation tollerances ± 0,5 up to ± 0,8 %
Means of overcoming the
Jahns is able to carry out test-bench simulations of
disadvantage of pressure drop
specified working conditions in order to determine • Often for cylinders the high pressure is only required
the synchronisation levels of a customer's particular in one flow direction. The flow divider can be built
application. In this way it is possible for the customer into the return line were the pressure is much lo-
to avoid incorporating large “safety margins” in the wer.
design. • In several applications synchronisation is not re-
quired during the high pressure phase of the work
Internal pressure drop in cycle, for example, in a 2 cylinder press synchronisa-
flow-divider valve. tion is only needed when the cylinders are working
You find the datas in the diagrams on page 10. at low pressure. During the high pressure phase of
the work cycle the flow divider can be by-passed
Internal pressure drop in using check valves.
gear-motor flow-dividers
Currently the decrease in pressure in the MTO series
geared oil-flow dividers must be calculated based on
the following pressure loss: 15-20 bar for size 2, 25-30
bar for size 3 and 30-40 bar for size 4. These values are
respective to an initial pressure of 150-180 bar and a
flow volume equating to 1200 revs./min.
Page 4 www.jahns-hydraulik.de
HYDRAULIK
Flow-divider application
Using a “driver” all cylinders are able to complete their strokes even
if one of them has reached the stroke-end. Valves 2
This is achieved by adding an extra section of equal or
and 3 maintain a minimum pressure of approx. 4 bar
greater displacement to the flow divider.The return line
in each of the flow divider sections. The difference of
of this section is connected directly to tank so that it
1 bar from the opening tension of valve 3 is due to the
in effect works as a motor for the other sections in the
opening tension of valves 2 of 1 bar.
flow divider thereby increasing their outlet pressures.
This is useful, for example, in lifting platforms that The minimum pressure feed is important, for example,
should lower under action of their own weight, but when one of the cylinder has reached its end stroke,
where the weight of the empty platform is insufficient but the flow divider continues running due to the slo-
for this to occur. wer cylinders. The pressure feed then prevents suction
occuring in the line connecting the fastest cylinder.
Compensating synchronisation Valve 4 has an important function which is often ig-
errors - installation of the flow nored on flow dividers: If the oil flow from the pump
reaches the cylinders and the flow divider has the task
divider in the hydraulic circuit
of collection the returnline oil in order to perform an
As the low divider is an independent flow control equalisation of the flows, valve 4 ensures that the flow
mechanism without any direct means of measuring divider is not made to run at the speed of the fastest
the synchronisations errors that will always occur, any cylinder then the other cylinders do not follow due
corrections have to take place as the cylinders reach to friction, loading, pinching etc.: the flow divider can
the end of their stroke. only operate as a collector if all the cylinders operate
at the same speed.
A pressure relief valve or an over-centre valve could be
used instead of the throttle valve 4.
The use of such a valve in the circuit becomes particu-
larly important when the cylinder return strokes occur
whitout a controlling pump flow, eg. under action of
their own weight.
Minimum flows
The gear flow-dividers in particular are not low speed
components. Generally the minimum flows per section
are as follows:
MTO : Qmin (l/min) = VKammer (cm3/U) x 0.5
Bei den Radialstromteilern gilt:
MT-GM : Qmin = 0.15 x Qmax
MTL : Qmin = 0.25 x Qmax
www.jahns-hydraulik.de Page 5
HYDRAULIK
Flow-divider application
Page 6 www.jahns-hydraulik.de
HYDRAULIK
Integral pressure valves in the MTO
The pressure control valves are set to Standardspring, colour red, standard,
these values preset to approx. 180 bar
The fact that the pressure valves are counter-sunk pressure Length L pressure Length L
means that it is not possible to adjust them, whilst at the (bar) (mm) (bar) (mm)
same time looking at the pressure manometer. In order 130 27,50 220 26,15
to set the valves it is necessary to remove the pressure 140 27,35 230 26,05
cartridge from the block. Since the safety valves need 150 27,20 240 25,90
not be set to a great degree of precision and can easily
160 27,05 250 25,80
accommodate a tolerance of 3 bar, it is possible to set
the valve by simply measuring the distance ‘L’ using a 170 26,90 260 25,65
calliper rule. In the diagrams (left) you can read off the 180 26,75 270 25,55
values for pressure = f(L) for the different springs. These 190 26,60 280 25,40
tables indicate the pressure levels and the correspond- 200 26,45 290 25,25
ing spring lengths. After installing the pressure control 210 26,30 300 25,15
valves again, the adjustment is completed.
Length L
pressure Length L pressure Length L
(bar) (mm) (bar) (mm)
60 26,6 120 25,0
70 26,3 130 24,8
80 26,0 140 24,5
90 25,8 150 24,2
100 25,6 160 24,0
110 25,3
www.jahns-hydraulik.de Page 7
HYDRAULIK
Flow-divider application
Page 8 www.jahns-hydraulik.de
HYDRAULIK
Integral pressure valves in the MTO
www.jahns-hydraulik.de Page 9
HYDRAULIK
Divider-valves
The valve produces 2 flows or riunifies 2 flows. The total flow should lie between the
minimum and maximum limits below. Within the flow-limits, the flow are nearly inde-
pendant of oil-pressure and viscosity.
Using this valve it's important to know that a stop of the first flow causes a throttling
of the second-one. This produces heat. Please take care of this fact.
Generally we recommead the alloy-version, last not least due to the lower costs. Only
a pressure of over 210 bar leads to the steel-version.
Order-code
Example: MKA-1/24
24 max. total flow (l/min)
1 Size
MKA Flow-divider valve in alloy
MKS Flow-divider valve in steel
Page 10 www.jahns-hydraulik.de
HYDRAULIK
Divider-valves
Size 1
Size 2
www.jahns-hydraulik.de Page 11
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 0
Size 0
MTO-..-1 0,99 0,35 1,5 4 250 280 200
Providing that the flow-noise is not an issue, it is possible to increase the pressure values in the chambers.
Order codes
Example: MTO-4-1-AVR 4-section flow-divider with all section of 0,99 cm³/rev, pressure valve adjustable
AVR Pressure control valves adjustable from 130 to 280 bar, standard
Spring colour red, preset to approx. 180 bar
AVG Pressure control valves adjustable from 90 to 200 bar,
Spring colour green, preset to approx. 120 bar
AVB Pressure control valves adjustable from 60 to 160 bar,
Spring colour blue, preset to approx. 100 bar
AVS Pressure control valves adjustable from 30 to 80 bar,
Spring colour black, preset to approx. 50 bar
G Divider without additional valves, threaded connector
Page 12 www.jahns-hydraulik.de
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 0
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 47,1 mm each section. MTO-..-..-G
Weight: MTO-..-1-G 1,1 kg/section
Connections
E1 to E2 G3/8" Input MTO-..-..-A...
A1 to A4 G1/4" Output, divided flows
T, NS G3/8" Tank and low-pressure-feeding
Weight: MTO-..-1-A 1,6 kg/section
www.jahns-hydraulik.de Page 13
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 1
Size 1
MTO-..-4 4,2 1,6 9 (10) 250 280 200
MTO-..-5 5,5 2,2 12 (14) 230 250 200
Size 2 Page16, 17
MTO-..-8 8,16 3,5 19 (22) 250 280 200
MTO-..-14 14,45 5,0 32 (39) 250 280 200
MTO-..-31 31,4 12,5 62 (70) 210 240 200
Providing that the flow-noise is not an issue, it is possible to increase the pressure values in the chambers.
Order codes
Example: MTO-4-5-AVR 4-section flow-divider with all section of 5,5 cm³/rev, pressure valve adjustable
AVR Pressure control valves adjustable from 130 to 280 bar, standard
Spring colour red, preset to approx. 180 bar
AVG Pressure control valves adjustable from 90 to 200 bar,
Spring colour green, preset to approx. 120 bar
AVB Pressure control valves adjustable from 60 to 160 bar,
Spring colour blue, preset to approx. 100 bar
AVS Pressure control valves adjustable from 30 to 80 bar,
Spring colour black, preset to approx. 50 bar
G Divider without additional valves, threaded connector
Page 14 www.jahns-hydraulik.de
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 1
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of B each section. MTO-..-..-G
Weight: MTO-..-4-G 1,1 kg/section
MTO-..-5-G 1,2 kg/section
Connections
E1 to E2 G1/2" Input MTO-..-..-A...
A1 to A4 G3/8" Output, divided flows
T, NS G3/8" Tank and low-pressure-feeding
Weight: MTO-..-4-A 1,6 kg/section
MTO-..-5-A 1,8 kg/section
www.jahns-hydraulik.de Page 15
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 2
Size 2
MTO-..-8 8,16 3,5 19 (22) 250 280 200
MTO-..-14 14,45 5,0 32 (39) 250 280 200
MTO-..-31 31,4 12,5 62 (70) 210 240 200
Providing that the flow-noise is not an issue, it is possible to increase the pressure values in the chambers.
Order codes
Example: MTO-4-8-AVR 4-section flow-divider with all section of 8,16 cm³/rev, pressure valve adjustable
AVR Pressure control valves adjustable from 130 to 280 bar, standard
Spring colour red, preset to approx. 180 bar
AVG Pressure control valves adjustable from 90 to 200 bar,
Spring colour green, preset to approx. 120 bar
AVB Pressure control valves adjustable from 60 to 160 bar,
Spring colour blue, preset to approx. 100 bar
AVS Pressure control valves adjustable from 30 to 80 bar,
Spring colour black, preset to approx. 50 bar
G Divider without additional valves, threaded connector
Page 16 www.jahns-hydraulik.de
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 2
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate
the total length with a difference of B each section. MTO-..-..-G
Weight: MTO-..-8-G 2,1 kg/section
MTO-..-14-G 2,6 kg/section
MTO-..-31-G 3,5 kg/section
Connections
E1 to E2 Input MTO-..-..-A..
A1 to A4 Output, divided flow
T, NS Tank and low-pressure-feeding Weight: MTO-..-8-A 2,7 kg/section
MTO-..-14-A 3,4 kg/section
MTO-..-31-A 4,5 kg/section
www.jahns-hydraulik.de Page 17
HYDRAULIK
MTO Gear flow-divider (cast iron housing) Size 3
Size 3
MTO-..-25 24,9 12 66 270 290
MTO-..-35 34,3 16 82 260 285
MTO-..-55 54,5 27 98 260 285
MTO-..-80 78,7 40 140 260 285
Order codes Example: MTO-4-55-EA7 4-section flow-divider with all sections of 54,5 cm³/rev.
G Threated connection
GB Threated connection, for valve block assembly
E Inlet block
A7 Outlet block, design series 7
Displacement per section
Number of section, maximum 8
Page 18 www.jahns-hydraulik.de
HYDRAULIK
MTO Gear flow-divider (cast iron housing) Size 3 EA7
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 167,5 mm each section. MTO-..-..-G
Connections Weight: 17 kg/section
E G1" Input
A1 to A4 G1" Output, divided flows
Connections
E G1 1/4" Input MTO-..-..-EA7
A1 to A4 G1 1/4" Output, divided flows
T, NS G1/2" Tank and low-pressure-feeding Weight: 22 kg/section
M1 to M4 G3/4" Measuring port for each section
Type A B C D
MTO-..-35 130,0 37,5 110,0 471,5
MTO-..-55 124,5 43,0 104,5 488,5
MTO-..-80 109,0 58,5 89,0 504,0
www.jahns-hydraulik.de Page 19
HYDRAULIK
Gear flow-divider (cast iron housing) MTO Size 3
Size 3
MTO-..-25 24,9 12 66 270 290
MTO-..-35 34,3 16 82 260 285
MTO-..-55 54,5 27 98 260 285
MTO-..-80 78,7 40 140 260 285
Order codes Example: MTO-4-55-EA9 4-section flow-divider with all sections of 54,5 cm³/rev.
G Threated connection
GB Threated connection, for valve block assembly
E Inlet block
A9 Outlet block, design series 9
Displacement per section
Number of section, maximum 8
Page 20 www.jahns-hydraulik.de
HYDRAULIK
Gear flow-divider (cast iron housing) MTO Size 3 EA9
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 167,5 mm each section. MTO-..-..-G
Connections Weight: 17 kg/section
E G1" Input
A1 to A4 G1" Output, divided flows
Connections
E G1 1/4" Input MTO-..-..-EA9
A1 to A4 G1 1/4" Output, divided flows
T, NS G1 1/4" Tank and low-pressure-feeding Weight: 36 kg/section
M1 to M4 G1/4" Measuring port for each section
Type A B C D
MTO-..-35 126,0 41,5 104,5 492,5
MTO-..-55 124,5 43,0 104,5 505,5
MTO-..-80 109,0 58,5 89,0 521,0
www.jahns-hydraulik.de Page 21
HYDRAULIK
MTO Gear flow-divider (cast iron housing) Size 4
Size 4
MTO-..-110 105,4 50 200 270 290
MTO-..-150 149,7 80 220 235 250
Order codes
Example: MTO-4-110-EA9 4-section flow-divider with all sections of 105,4 cm³/rev.
Page 22 www.jahns-hydraulik.de
HYDRAULIK
MTO Gear flow-divider (cast iron housing) Size 4
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of B each section. MTO-..-...-S
Connections
Weight: 25 kg/section
E1 to E4 SAE1 1/2" 3000 psi, Input
A1 to A4 SAE1 1/2" 3000 psi, Output, divided flows
Connections
E1 to E2 SAE 2" 6000 psi, Input
MTO-..-...-EA9
A1 to A4 SAE1 1/2" 6000 psi, Output, divided flows
T, NS G1 1/4" Tank and low-pressure-feeding Weight: 56 kg/section
M1 to M4 G1/4" Measuring port for each section
Typ B C D F G H
MTO-..-110 171 117 683,5 99,5 92 419
MTO-..-150 187 133 747,5 102,5 95 387
www.jahns-hydraulik.de Page 23
HYDRAULIK
HTO Gear flow-divider (cast iron housing) Size 3
Size 3
HTO-..-35 34,3 12 82 320 380
HTO-..-80 78,7 27 140 320 380
Order codes Example: HTO-4-35-FI 4-section flow-divider with all sections of 34,3 cm³/rev.
F with feet
I with valves
V viton seals
Displacement per section
Number of section, maximum 12
Page 24 www.jahns-hydraulik.de
HYDRAULIK
HTO Gear flow-divider (cast iron housing) Size 3
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 167,5 mm each section. HTO-..-..-FI
Weight: 40 kg/section
Connections
E1 to E4 SAE NW32 420 bar (1 1/4", 6000 psi), Input
A1 to A4 SAE NW25 420 bar (1", 6000 psi), Output, divided flows
T, NS G3/4" Tank and low-pressure-feeding
ME G1/4" Measuring, input
M1 to M4 G1/4" Measuring port for each section, output
www.jahns-hydraulik.de Page 25
HYDRAULIK
HTO Gear flow-divider (cast iron housing) Size 4
Size 4
HTO-..-110 105,4 50 200 320 380
HTO-..-150 149,7 80 220 320 380
Order codes
Example: HTO-4-110-FI 4-section flow-divider with all sections of 105,4 cm³/rev.
F with feet
I with valves
V viton seals
Page 26 www.jahns-hydraulik.de
HYDRAULIK
HTO Gear flow-divider (cast iron housing) Size 4
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 194 mm each section. HTO-..-...-FI
Weight: 75 kg/section
Connections
E1 to E2 SAE NW40 420 bar (1 1/2", 6000 psi), Input
A1 to A4 SAE NW40 420 bar (1 1/2", 6000 psi), Output, divided flows
T, NS G1" Tank and low-pressure-feeding
ME G1/4" Measuring, input
M1 to M4 G1/4" Measuring port for each section, output
www.jahns-hydraulik.de Page 27
HYDRAULIK
Radial piston flow divider MT-GM
MT-GM1... / ...-FG
Weight: 70 kg
Connections
E1 - E2 G1" Input, to be connected together
A1 - A2 G1" Output, section-flows
L1 - L2 G1/4" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
Page 28 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MT-GM
MT-GM2... / ...-FG
Weight: 130 kg
Connections
E1 - E2 G1" Input, to be connected together
A1 - A2 G1" Output, section-flows
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
MT-GM3... / ...-FG
Weight: 215 kg
Connections
E1 - E2 G1" Input, to be connected together
A1 - A2 G1" Output, section-flows
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
www.jahns-hydraulik.de Page 29
HYDRAULIK
Radial piston flow divider MT-GM
MT-GM5... / ...-FS
Weight: 425 kg
Connections
E1 - E2 SAE 1 1/2" Input, to be connected together
A1 - A2 SAE 1 1/2" Output, section-flows
L1 - L2 G1/2" Drain-ports
Important: both ports have to be connected to the tank !
MT-GM6... / ...-FS
Weight: 550 kg
Connection
E1 - E2 SAE 1 1/2" Input, to be connected together
A1 - A2 SAE 1 1/2" Output, section-flows
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
Page 30 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MT-GM
MT-GM1... / ...-FEA
Weight: 90 kg
Connection
E1 - E2 G1 1/4" Input, alternatively
A1 - A2 G1" Output, section-flows
L1 - L2 G1/4" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G3/8" Tank- and low-pressure-feeding
M1 - M2 G3/8" Measuringport for each sections
www.jahns-hydraulik.de Page 31
HYDRAULIK
Radial piston flow divider MT-GM
MT-GM2... / ...-FEA
Weight: 150 kg
Connections
E1, E2 G1 1/4" Input, alternatively
A1, A2 G1" Output, section-flows
L1, L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G3/8" Tank- and low-pressure-feeding
M1 , M2 G3/8" Measuringport for each sections
MT-GM3-... / ...-FEA
Weight: 240 kg
Connections
E1, E2 NW 40 / G1 1/4" Input, alternatively
A1, A2 G1 1/4" Output, section-flows
L1, L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G3/4" Tank- and low-pressure-feeding
M1, M2 G1/2" Measuringport for each sections
Page 32 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MT-GM
Connections
E1 - E2 SAE 1 1/2" Input, to be connected together
MT-GM5... / ...-FEA
A1 - A2 SAE 1 1/2" Output, section-flows Weight: 480 kg
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G1 1/2" Tank- and low-pressure-feeding,to be connected together
M1, M2 G1/4" Measuringport
Connections
E1 - E2 SAE 1 1/2" Input, to be connected together
MT-GM6... / ...-FEA
A1 - A2 SAE 1 1/2" Output, section-flows Weight: 725 kg
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G1 1/2" Tank- and low-pressure-feeding, to be connected together
M1, M2 G1/4" Measuringport
www.jahns-hydraulik.de Page 33
HYDRAULIK
Radial piston flow divider MTL
Complete drawings of the series MTL-2/29 to MTL-12/270 of different sizes are available upon request.
G Threated connection
E Inlet block, see pages 32, 33
A Outlet block, see pages 32, 33
29 Displacement of each section
4 Number of sections
Connections
MTL ../ 29-G A1 to A4 or B1 to B4 G3/4" Input, to be connected together
MTL ../ 42-G B1 to B4 or A1 to A4 G3/4" Output, section-flows
L G1/2" Drain-ports, drain pressure max. 10 bar
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 130 mm each section.
Page 34 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MTL
Connections
A1 to A4 or B1 to B4 G1/4" Input, to be connected together
MTL../ 70-G
B1 to B4 or A1 to A4 G1/4" Output, section-flows MTL../ 108-G
L G3/4" Drain-ports, drain pressure max. 10 bar
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 155 mm each section.
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 255 mm each section.
www.jahns-hydraulik.de Page 35
HYDRAULIK
Radial piston flow divider MTL
Complete drawings of the series MTL-2/29 to MTL-12/270 of different sizes are available upon request.
G Threated connection
E Inlet block
A Outlet block
29 Displacement of each section
4 Number of sections
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 130 mm each section.
Weight: MTL-../29-EA and MTL-../42-EA 36 kg/section
Page 36 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MTL
Connections circuit according DIN ISO 1219
E G1 1/2" Input
MTL../ 70-EA2
A1 to A4 G1 1/4" Output, divided flows MTL../ 108-EA2
L G3/4" Drain port,
drain-pressure max. 10 bar
T, NS G1 1/4" Tank and low-pressure-feeding
M1 to M4 G1/4" Measuring port for each section
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 155 mm each section.
Weight: MTL-../70-EA and MTL-../108-EA 74 kg/section
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 255 mm each section.
Weight: MTL-../170-EA and MTL-../270-EA 167 kg/section
www.jahns-hydraulik.de Page 37
HYDRAULIK
Radial piston flow divider STL
Complete drawings of the series STL-2-220 to STL-12-320 of different sizes are available upon request.
Page 38 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider STL
Connections
E1 to E4 SAE NW50, 6000 psi Input
STL..- 220-S
A1 to A4 SAE NW50, 6000 psi Output, divided flows STL..- 320-S
L G1" Drain port,
drain-pressure max. 10 bar
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 280 mm each section.
Weight: STL-..-220-S and STL-..-320-S 240 kg/section
Connections
E1 to E2 SAE 2 1/2", 6000 psi Input
circuit according DIN ISO 1219 STL..- 220-EA
A1 to A4 SAE NW50, 6000 psi Output, divided flows STL..- 320-EA
L G1" Drain port,
drain-pressure max. 10 bar
T, NS SAE NW50, 3000 psi Tank and low-pressure-feeding
M1 to M4 G1/4" Measuring port for each section
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 280 mm each section.
Weight: STL-..-220-EA and STL-..-320-EA 296 kg/section
www.jahns-hydraulik.de Page 39
HYDRAULIK
Components for hydraulics and process technology