Location via proxy:   [ UP ]  
[Report a bug]   [Manage cookies]                

Flow Divider Designs: Hydraulik

Download as pdf or txt
Download as pdf or txt
You are on page 1of 40

HYDRAULIK

Flow divider designs

Edition 28.01

Jahns-Regulatoren GmbH

D 63069 Offenbach Sprendlinger Landstraße 150 Telephon +49 (0)69 848477-0


D 63009 Offenbach Postbox 10 09 52 Telefax +49 (0)69 84847725
http://www.jahns-hydraulik.de info@jahns-hydraulik.de
Contents

Flow-divider applications
Synchronised running ....................................................................................................................... 3
Pressure multipliers ............................................................................................................................ 3
Lubricating-oil flow divider ............................................................................................................. 3
Synchronisation differences............................................................................................................ 4
Internal pressure-drop....................................................................................................................... 4
Means of overcoming the pressure-drop................................................................................... 4
Using a “driver”...................................................................................................................................... 5
Compensating synchronisation-errors........................................................................................ 5
Hydraulic fluids .................................................................................................................................... 6
Noise-levels ........................................................................................................................................... 6
Applications limits .............................................................................................................................. 6
Synchronisation ratios....................................................................................................................... 6
Synchronisation errors due to differnt oil-compression ....................................................... 6
Inlet/outlet-blocks ............................................................................................................................. 6
Use of other fluids than mineraloil................................................................................................ 6
How to install the flow divider, start-up ...................................................................................... 7
Integral pressure valves .................................................................................................................... 8
Installation instructions, Commissioning ................................................................................... 9

Technical datas, dimensions

Series MKA, MKS, valves for 2 sections


Size 1, size 2 ..................................................................................................................................10, 11

Series MTO, Aluminium housing, for 2 up to 12 sections


Size 0 ...............................................................................................................................................12, 13
Size 1 ...............................................................................................................................................14, 15
Size 2 ...............................................................................................................................................16, 17

Series MTO, Cast Iron housing, for 2 up to 12 sections


Size 3, Inlet and Outletblock EA7 in aluminium..............................................................18, 19
Size 3, Inlet and Outletblock EA9 in steel ..........................................................................20, 21
Size 4, Inlet and Outletblock EA9 in steel ..........................................................................22, 23

Series HTO, Cast Iron housing, for 2 up to 12 sections


Size 3............................................................................................................................................... 24, 25
Size 4............................................................................................................................................... 26, 27

Series MT-GM, only 2 sections


MT-GM1 - MT-GM6, without Inlet/Outletblock.............................................................. 28 - 30
MT-GM1 - MT-GM6, with Inlet/Outletblock .................................................................... 31 - 33

Series MTL and STL, for 2 up to 12 sections


MTL-../29 - MTL-../270, without Inlet/Outletblock ..........................................................34, 35
MTL-../29 - MTL-../270, with Inlet/Outletblock .................................................................36, 37
STL-../220 - STL-../320, with and without Inlet/Outletblock ........................................38, 39
© Jahns Regulatoren GmbH 2004, 2005, 2006, 2007, 2009, 2010, 2011, 2014, 2016, 2017

Reprinting, even partially, not permitted.


No responsibility for possible errors in catalogues or other printed material is accepted.
Former catalogues lost their validity.
Catalogues are subject to be changed.

Page 2 www.jahns-hydraulik.de
HYDRAULIK
Flow-divider application

Synchronised running The pressure values in the example diagramm below


are indicative of an MT. The theoretical out-put pressure
If several motors or cylinders are operate from a single
value of approx. 400 bar will be lower due to effiency
pump without any means of controlling their individual
losses. It should be noted that the pressure gain achie-
flows only the motor or cylinder with the lowest pres-
vedis made possible through an increase in system flow.
sure requirement would start its work cycle. The motor
This type of hydraulic circuit can be used where a low
or cylinder with the next lowest pressure requirement
pressure circuit is already in use and where there is only
would only start when the first unit has completed its
need of small high pressure flow.
work cycle. This mode of operation is generally unde-
sirable and it is therefore necessary for the total pump The installation of a supplementary high pressure cir-
flow to be divided into a series of partia flows.This can cuit with pump, electric motor, pressure relief valve and
be achieved in the following ways: manometer would not be convient in this case as it
would be possible to utilise the existing low pressure
• Throttles or flow regulation valves in each of the
circuit.
motor or cylinders connections.
• Oprerating the units in a series circuit.
• With flow divider valves for 2 sections.
• With flow dividers of various designs.
Jahns flow dividers are of the rotating motor type and
offer, indipendently of their design, the following syn-
pHD = 265 bar
chronisation advantages:
• High degree of synchronisation even with the simp-
ler gear-motor flow-dividers.
QND = 60 l/min
QHD = 20 l/min
• High degree of synchronisation is maintained over V1 = 115 cm³/rev
V2 = 350 cm³/rev
a wide range of flows.
• Due to low leakage rates in the individual section
the high degree of synchronisation is main-tained
with differing load conditions.
The use of flow dividers is not complicated if applied
withan appropriate hydraulic circuit design. Additional
installation alterations are not necessary. QE = 82 l/min
pE = 100 bar
For applications,where only a lower degree of syn-chro-
nisation is necessary, Jahns offers flow divider valves,
too. These valves are a very economic alternative. See
page 8.

Pressure multipliers
As mentioned earlier as well as operating as a synchro- Lubricating-oil flow-divider
nising instrument the flow divider can be utilised as Shafts with multiple sets of friction bearings require
a pressure multiplier. The entire range of gear-motor a sure supply of lubrificating oil in equal quantities to
flow dividers can be used for this type of application each of the bearings.With the gear-motor flow dividers,
and due their low internal pressure losses and low cost that do not have any external leakages, if the gear of
they often represent the optimal solution. one of the sections are turning then a synchronised
The cast-iron MTO range should be used when it is flow in all the other sections is ensured. It is therefore
necessary to increase the output pressure to values only necessary to check the speed of on of the shafts
around 280 bar. There is the option of requesting special with anelectronic sensor and Jahns can be supply the
versions with individual sections having varying absorp- component required for this solution.
tion volumes. This enables pressures to be increased
by a factor of three, four and more.

www.jahns-hydraulik.de Page 3
HYDRAULIK
Flow-divider application

Synchronisation differences If it is important for you to know the actual value, please
enquire providing details as regards the respective
With particular reference to the gear-motor flow divi-
pressure, oil flow-rate and oil viscosity.
ders MTO but also for the radial-motor flow dividers
MT-GM and MTL synchronisation differences depend Internal pressure drop in
on the following parameters:
radial-piston flow-dividers
• Oil viscosity and temperature
The radial piston motor design has larger pressure drops
• Pressure load varability than the gear motor design and the pressure drop also
• System pressure levels depend on the outlet pressure. The following of the
outlet pressure for all MT-GM an MTL models:
• Total flow rate to be divided
Precise indications of synchronisation levels are only
possible if the details of all the above parameters are Required Input Pressure
known. output pressure pressure drop
A general indication may be obtained from the follo- (bar) (bar) (bar)
wing values:
MK under maximum oil-flow-values in the catalogue 50 60 10
synchronisation tollerances ± 4,0 up to ± 5,0 %
100 120 20
MTO Size 0 (aluminium housing)
140 175 35
synchronisation tollerances ± 2,0 up to ± 3,0 %
150 190 40
MTO Size 1 and 2 (aluminium housing)
running more than 1200 rpm 180 225 45
synchronisation tollerances ± 1,5 up to ± 2,0 % 190 240 50
MTO Size 3 and 4 (cast iron housing) 210 265 55
synchronisation tollerances ± 3 up to ± 4 %
230 285 55
HTO synchronisation tollerances ± 3 up to ± 4 %
Pressure drop in radial-piston flow-dividers MT-GM and MTL
MT-GM synchronisation tollerances ± 0,5 up to ± 0,8 %
MTL synchronisation tollerances ± 0,5 up to ± 0,8 %
Means of overcoming the
Jahns is able to carry out test-bench simulations of
disadvantage of pressure drop
specified working conditions in order to determine • Often for cylinders the high pressure is only required
the synchronisation levels of a customer's particular in one flow direction. The flow divider can be built
application. In this way it is possible for the customer into the return line were the pressure is much lo-
to avoid incorporating large “safety margins” in the wer.
design. • In several applications synchronisation is not re-
quired during the high pressure phase of the work
Internal pressure drop in cycle, for example, in a 2 cylinder press synchronisa-
flow-divider valve. tion is only needed when the cylinders are working
You find the datas in the diagrams on page 10. at low pressure. During the high pressure phase of
the work cycle the flow divider can be by-passed
Internal pressure drop in using check valves.
gear-motor flow-dividers
Currently the decrease in pressure in the MTO series
geared oil-flow dividers must be calculated based on
the following pressure loss: 15-20 bar for size 2, 25-30
bar for size 3 and 30-40 bar for size 4. These values are
respective to an initial pressure of 150-180 bar and a
flow volume equating to 1200 revs./min.

Page 4 www.jahns-hydraulik.de
HYDRAULIK
Flow-divider application

Using a “driver” all cylinders are able to complete their strokes even
if one of them has reached the stroke-end. Valves 2
This is achieved by adding an extra section of equal or
and 3 maintain a minimum pressure of approx. 4 bar
greater displacement to the flow divider.The return line
in each of the flow divider sections. The difference of
of this section is connected directly to tank so that it
1 bar from the opening tension of valve 3 is due to the
in effect works as a motor for the other sections in the
opening tension of valves 2 of 1 bar.
flow divider thereby increasing their outlet pressures.
This is useful, for example, in lifting platforms that The minimum pressure feed is important, for example,
should lower under action of their own weight, but when one of the cylinder has reached its end stroke,
where the weight of the empty platform is insufficient but the flow divider continues running due to the slo-
for this to occur. wer cylinders. The pressure feed then prevents suction
occuring in the line connecting the fastest cylinder.
Compensating synchronisation Valve 4 has an important function which is often ig-
errors - installation of the flow nored on flow dividers: If the oil flow from the pump
reaches the cylinders and the flow divider has the task
divider in the hydraulic circuit
of collection the returnline oil in order to perform an
As the low divider is an independent flow control equalisation of the flows, valve 4 ensures that the flow
mechanism without any direct means of measuring divider is not made to run at the speed of the fastest
the synchronisations errors that will always occur, any cylinder then the other cylinders do not follow due
corrections have to take place as the cylinders reach to friction, loading, pinching etc.: the flow divider can
the end of their stroke. only operate as a collector if all the cylinders operate
at the same speed.
A pressure relief valve or an over-centre valve could be
used instead of the throttle valve 4.
The use of such a valve in the circuit becomes particu-
larly important when the cylinder return strokes occur
whitout a controlling pump flow, eg. under action of
their own weight.

Minimum flows
The gear flow-dividers in particular are not low speed
components. Generally the minimum flows per section
are as follows:
MTO : Qmin (l/min) = VKammer (cm3/U) x 0.5
Bei den Radialstromteilern gilt:
MT-GM : Qmin = 0.15 x Qmax
MTL : Qmin = 0.25 x Qmax

The diagramm shows an example of such a circuit. The


valves in the circuit have the following functions: The
pressure relief valves 1 serve as protection against
excess pressure in the cylinder outlet lines as may be
caused by the pressure multiplier effect. In this way

www.jahns-hydraulik.de Page 5
HYDRAULIK
Flow-divider application

Hydraulic fluids Application limits


Our flow dividers are designed to be used with mineral Due to the propensity of all flow dividers to leak oil it
oil in accordance with DIN 51524. is not possible to keep the cylinders under pressure
The operating temperature range is fixed at -25°C to for an extended period of time. As a consequence it
+80°C with normal seals and -25°C to +100°C when is necessary to fit pilot-operated non-return valves in
using Viton seals. every line between flow divider and cylinder.
The recommended oil viscosity is between 12 and 100 Flow dividers are not able to compensate for the error
cSt, while at start-up they are approved for maximum (0.07% per 10 bar) due to differential oil compression
values up to 600 cSt. at varying load pressures.
For very short stroke or cycle times and also for small
Use of other fluids than mineraloil cylinder volumes our MZB volume synchronisers are
Specially the radial-piston flow dividers, but the flow- potentially a better solution. Please contact us for more
divider valves, too, accept other fluids than mineraloil, information.
such as HFC, HFD, non-contaminating fluids. Please If you are considering the use of flow dividers but you
contact Jahns in those cases. are not sure whether using flow dividers will work,please
Flow divider start-up contact us,preferably by sending us the intended circuit
The smallest flow dividers in particular do not start if diagram. Due to our many years of experience working
there is already a high outlet pressure at the beginning with our customers in this area,we will be able to provide
of the cycle. you with the best possible application advice.
This situation occurs, for example, with the flow divider Synchronisation errors due to
installed between the pump and cylinders, when the
lifting of a load is stopped and held by pressure in the
differing oil compression
flow divider outlet. The flow divider is not able to compensate for errors
due to differing oil compression caused by differing
In this case it is possible to use check valves to hold the
cylinder loads. It is advisable to minimise oil volumes
load while the flow divider outlets are relieved of pres-
between the flow divider and the cylinder by using
sure. Depending on the type of application a variety of
short tubes of equal length for all cylinders. If the
solutions are possible; it is merely a question of taking
difference in load in the cylinders is unchanging then
this into consideration when designing the circuit.
it is possible to correect or eliminate oil compression
Noise-leves synchronisaton errors with the appropriate use of
Specially the gear-motor flow dividers cause a noise- pressure relief valves.
level running over 1800 rpm that can not always be Inlet / outlet-blocks
accepted. Please choice the displacement according
To achieve a minimum of piping and fittings and to
to this fact.
guarantee the proved quality of important valves for
Synchronisation ratios the hydraulic circuit, you can get from Jahns so called
In general, the synchronisation ratio required is 1:1. inlet/outlet blocks for MTZ, MT and MTL flow divider.
Different ratios are possible on request. If so, please They have to be ordered directly together with the flow
contact Jahns technical staff. Obtaining different ratios dividers, because a later assembly is generally impos-
is made easier if it is possible to obtain the required sible or causes problems. The blocks for the MT series
section displacement difference in the same section are not separated into inlet/outlet ports, but integrated
housing. in one block only.
The present outlet-blocks have a relief-valve for each
section and a separate port to measure the pressure.
The pressure a setting should be done, when the cylin-
der are in the external stroke-end.The pressure-setting
should be 20 bar over the pressure to lift the cylinder
with their charge. The port NS, T should be coneccted
with the return-line. This return-line should have a
pretension of 3-5 bar.

Page 6 www.jahns-hydraulik.de
HYDRAULIK
Integral pressure valves in the MTO

The pressure control valves are set to Standardspring, colour red, standard,
these values preset to approx. 180 bar

The fact that the pressure valves are counter-sunk pressure Length L pressure Length L
means that it is not possible to adjust them, whilst at the (bar) (mm) (bar) (mm)
same time looking at the pressure manometer. In order 130 27,50 220 26,15
to set the valves it is necessary to remove the pressure 140 27,35 230 26,05
cartridge from the block. Since the safety valves need 150 27,20 240 25,90
not be set to a great degree of precision and can easily
160 27,05 250 25,80
accommodate a tolerance of 3 bar, it is possible to set
the valve by simply measuring the distance ‘L’ using a 170 26,90 260 25,65
calliper rule. In the diagrams (left) you can read off the 180 26,75 270 25,55
values for pressure = f(L) for the different springs. These 190 26,60 280 25,40
tables indicate the pressure levels and the correspond- 200 26,45 290 25,25
ing spring lengths. After installing the pressure control 210 26,30 300 25,15
valves again, the adjustment is completed.

Specialspring, colour green, preset to approx. 120 bar

pressure Length L pressure Length L


(bar) (mm) (bar) (mm)

90 26,80 150 25,70


100 26,60 160 25,55
110 26,40 170 25,35
120 26,25 180 25,20
130 26,05 190 25,00
140 25,90 200 24,80

Specialspring, colour blue, preset to approx. 100 bar

Length L
pressure Length L pressure Length L
(bar) (mm) (bar) (mm)
60 26,6 120 25,0
70 26,3 130 24,8
80 26,0 140 24,5
90 25,8 150 24,2
100 25,6 160 24,0
110 25,3

Specialspring, colour black, preset to approx. 50 bar

pressure Length L pressure Length L


(bar) (mm) (bar) (mm)
30 26,2 60 25,3
40 25,9 70 25,0
50 25,6 80 24,7

www.jahns-hydraulik.de Page 7
HYDRAULIK
Flow-divider application

MTO Sizes 0 to 2 Assembly-position of inputs and


Aluminium housing. The different displacements of outputs MTO Size 1 and 2
units within the same size are indicated by the width
of the housing.
It is possible to interconnect flow dividers of any dis- 2
placement listed in the tables. The same is also possible
in terms of combining both component groups. This is
important when they are used as pressure boosters. 3
The inlets to the individual chambers are interconnected
internally. The number of connections on the inlet side
must be based on the flow to be divided.
4
In version‘A’each section has a combined pressure relief
and suction valve which is incorporated directly in the
housing. Although the pressure relief valves are adjus-
table, they are concealed so as to prevent unregulated, 5
operational adjustment. However, they can be adjusted
should it be necessary to do so.
MTO Sizes 3 and 4 6
Cast iron housing. All Size 3 units have the same width
of housing irrespective of displacements.The individual
sections of the flow dividers are bolted together. 7
The flow dividers can also be supplied with inlet and
outlet blocks.
MTO Size 3 EA7 (aluminium) 8
EA9 (steel)
MTO Size 4 EA9 (steel)
If no inlet block is used, every inlet on the flow divider 9
must be connected.
HTO Sizes 3 and 4
Cast iron housing. Irrespective of displacement there is 10
only one width of housing in each range.The individual
sections of the flow dividers are bolted together, which
facilitates assembly and disassembly. 11
The operating pressure for the HTO is 320 bar.
The housing incorporates an inlet and outlet block.
Couplings are used to connect the individual sections. 12
The number of connections on the inlet side must be
based on the flow to be divided.
In the case of the size 4 it is necessary to connect up at
least every second connection.

Page 8 www.jahns-hydraulik.de
HYDRAULIK
Integral pressure valves in the MTO

General points chambers of the divider. Leakage oil pressure maximum


of 10 bar, or a maximum of 1.5 bar for versions with
Flow dividers must be fitted as close to the cylinders
protruding measurement shaft.
as possible and the pipe connections to the individual
chambers must be of equal length, as far as this is Commissioning
possible.
The radial piston flow divider produces minimal leakage
Hydraulic fluids, viscosities oil. As a result it is necessary to fill the housing with oil
before commissioning; otherwise the period the flow
Oil flow dividers are designed for use of mineral oil in
divider runs dry will be much too long before it is lubri-
accordance with DIN 51524. The recommended oil vis-
cated by its own leakage oil. Regrettably this important
cosity is between 12 and 100 cSt, while at start-up they
point is seldom taken into account.
are approved for maximum values up to 600 cSt.
Temperature range Low pressure feed and tank line
In the case of flow dividers with integral outlet blocks
The operating temperature range is fixed at -25°C to
or integrated valves it is essential to ensure that the low
+80°C with normal seals and at -25°C to +100°C when
pressure feed / tank line is connected correctly. Please
using Viton seals.
check page 5 of the circuit diagram!
Filtration
Filtration is of critical importance especially to achieve
high levels of synchronisation. Ultimately it is necessary
to achieve the crucial metallic seal between the exter-
nal surfaces of the gears and the internal bore of the
housing. In any case over the past few years the subject
of filtration has no longer been an issue, with the aim
being not to accommodate a lower level of filtration,
but to highlight the benefits of good filtration for the
whole system. We recommend a nominal filter rating
of 10 µm and an absolute value of 25 µm.
Oil or filter changes are to be carried out in accordance
with the recommendations of the machine or oil ma-
nufacturer.
Installation instructions
In the case of valves for piston flow divider installation
in the horizontal plane is the only essential requirement.
Otherwise there are not special issues with regards to
commissioning.
Gear flow dividers do not have a leakage oil con-
nection and do not need to be filled with oil before
commissioning.
Radial piston flow dividers in the MT range have two
leakage oil connections that must both be connected.
The leakage oil pressure must be a maximum of 1.5 bar.
The leakage oil pipes must be fitted so that the housing
cannot run dry. They must be unpressurised and return
the oil to the tank.
In the MTL range of radial piston flow dividers there
is a connection for leakage oil at both the beginning
and the end. Only one of these needs to be connected,
because the leakage oil chamber is connected to all

www.jahns-hydraulik.de Page 9
HYDRAULIK
Divider-valves

The valve produces 2 flows or riunifies 2 flows. The total flow should lie between the
minimum and maximum limits below. Within the flow-limits, the flow are nearly inde-
pendant of oil-pressure and viscosity.
Using this valve it's important to know that a stop of the first flow causes a throttling
of the second-one. This produces heat. Please take care of this fact.
Generally we recommead the alloy-version, last not least due to the lower costs. Only
a pressure of over 210 bar leads to the steel-version.

Total flow Total flow Peak-pressure Peak-pressure


Type minimal maximal Type MKA Type MKS
(l/min) (l/min) (bar) (bar)
MKS-0 / 6 2 6 - 315
MKA-1/12
4 12 210 350
MKS-1/12
MKA-1/24
12 24 210 350
MKS-1/24
MKA-1/40
24 40 210 350
MKS-1/40
MKA-2/90
40 90 210 350
MKS-2/90
MKA-2/150
90 150 210 350
MKS-2/150

Order-code
Example: MKA-1/24
24 max. total flow (l/min)
1 Size
MKA Flow-divider valve in alloy
MKS Flow-divider valve in steel

Circuit according DIN ISO 1219

Internal pressure-drop in flow-divider-valves

Page 10 www.jahns-hydraulik.de
HYDRAULIK
Divider-valves

Size 1

Type E A Weight MKA Weight MKS


MKA / MKS -1/12 G3/8" G3/8" 0,80 kg 1,85 kg
MKA / MKS-1/24 G3/8" G3/8" 0,85 kg 1,90 kg
MKA / MKS-1/40 G1/2" G3/8" 0,85 kg 1,90 kg

Size 2

Type E A Weight MKA Weight MKS


MKA / MKS -2/90 G3/4" G1/2" 2,1 kg 4,4 kg
MKA / MKS-2/150 G1" G3/4" 2,2 kg 4,5 kg

www.jahns-hydraulik.de Page 11
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 0

max. pressure difference


Displacement min. flow rec. flow max. flow Continue Peak
between the
Type per section per section per section per section pressure pressure
sections outputs
(cm3/U) (l/min) (l/min) (l/min) (bar) (bar)
(bar)

Size 0
MTO-..-1 0,99 0,35 1,5 4 250 280 200

Size 1 Page 14, 15


MTO-..-4 4,2 1,6 5,0 9 (10) 250 280 200
MTO-..-5 5,5 2,2 7,5 12 (14) 230 250 200

Size 2 Page 16, 17


MTO-..-8 8,16 3,5 12 19 (22) 250 280 200
MTO-..-14 14,45 5,0 20 32 (39) 250 280 200
MTO-..-31 31,4 12,5 35 62 (70) 210 240 200

Providing that the flow-noise is not an issue, it is possible to increase the pressure values in the chambers.

Order codes
Example: MTO-4-1-AVR 4-section flow-divider with all section of 0,99 cm³/rev, pressure valve adjustable

AVR Pressure control valves adjustable from 130 to 280 bar, standard
Spring colour red, preset to approx. 180 bar
AVG Pressure control valves adjustable from 90 to 200 bar,
Spring colour green, preset to approx. 120 bar
AVB Pressure control valves adjustable from 60 to 160 bar,
Spring colour blue, preset to approx. 100 bar
AVS Pressure control valves adjustable from 30 to 80 bar,
Spring colour black, preset to approx. 50 bar
G Divider without additional valves, threaded connector

1 Nominal displacement per chamber,


actual displacement see above
4 Number of part flows, maximum 12

Page 12 www.jahns-hydraulik.de
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 0
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 47,1 mm each section. MTO-..-..-G
Weight: MTO-..-1-G 1,1 kg/section

Connections
E1 to E2 G3/8" Input MTO-..-..-A...
A1 to A4 G1/4" Output, divided flows
T, NS G3/8" Tank and low-pressure-feeding
Weight: MTO-..-1-A 1,6 kg/section

Circuit according DIN ISO 1219

www.jahns-hydraulik.de Page 13
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 1

max. pressure difference


Displacement min. flow max. flow Continue Peak
between the
Type per section per section per section pressure pressure
sections outputs
(cm3/rev) (l/min) (l/min) (bar) (bar)
(bar)

Size 1
MTO-..-4 4,2 1,6 9 (10) 250 280 200
MTO-..-5 5,5 2,2 12 (14) 230 250 200

Size 2 Page16, 17
MTO-..-8 8,16 3,5 19 (22) 250 280 200
MTO-..-14 14,45 5,0 32 (39) 250 280 200
MTO-..-31 31,4 12,5 62 (70) 210 240 200
Providing that the flow-noise is not an issue, it is possible to increase the pressure values in the chambers.

Order codes
Example: MTO-4-5-AVR 4-section flow-divider with all section of 5,5 cm³/rev, pressure valve adjustable

AVR Pressure control valves adjustable from 130 to 280 bar, standard
Spring colour red, preset to approx. 180 bar
AVG Pressure control valves adjustable from 90 to 200 bar,
Spring colour green, preset to approx. 120 bar
AVB Pressure control valves adjustable from 60 to 160 bar,
Spring colour blue, preset to approx. 100 bar
AVS Pressure control valves adjustable from 30 to 80 bar,
Spring colour black, preset to approx. 50 bar
G Divider without additional valves, threaded connector

5 Nominal displacement per chamber,


actual displacement see above
4 Number of part flows, maximum 12

Page 14 www.jahns-hydraulik.de
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 1
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of B each section. MTO-..-..-G
Weight: MTO-..-4-G 1,1 kg/section
MTO-..-5-G 1,2 kg/section

Connections
E1 to E2 G1/2" Input MTO-..-..-A...
A1 to A4 G3/8" Output, divided flows
T, NS G3/8" Tank and low-pressure-feeding
Weight: MTO-..-4-A 1,6 kg/section
MTO-..-5-A 1,8 kg/section

Circuit according DIN ISO 1219

Type A1-4 E1-2 T/NS B C D F G H


MTO-..-4 80,5 50,7 344,3 51,4 412,1 85,3
G3/8" G1/2" G3/8"
MTO-..-5 85,7 55,9 364,9 53,9 432,7 87,8

www.jahns-hydraulik.de Page 15
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 2

max. pressure difference


Displacement min. flow max. flow Continue Peak
between the
Type per section per section per section pressure pressure
sections outputs
(cm3/rev) (l/min) (l/min) (bar) (bar)
(bar)

Size 1Page 12, 13


MTO-..-4 4,2 1,6 9 (10) 250 280 200
MTO-..-5 5,5 2,2 12 (14) 230 250 200

Size 2
MTO-..-8 8,16 3,5 19 (22) 250 280 200
MTO-..-14 14,45 5,0 32 (39) 250 280 200
MTO-..-31 31,4 12,5 62 (70) 210 240 200
Providing that the flow-noise is not an issue, it is possible to increase the pressure values in the chambers.

Order codes
Example: MTO-4-8-AVR 4-section flow-divider with all section of 8,16 cm³/rev, pressure valve adjustable

AVR Pressure control valves adjustable from 130 to 280 bar, standard
Spring colour red, preset to approx. 180 bar
AVG Pressure control valves adjustable from 90 to 200 bar,
Spring colour green, preset to approx. 120 bar
AVB Pressure control valves adjustable from 60 to 160 bar,
Spring colour blue, preset to approx. 100 bar
AVS Pressure control valves adjustable from 30 to 80 bar,
Spring colour black, preset to approx. 50 bar
G Divider without additional valves, threaded connector

5 Nominal displacement per chamber,


actual displacement see above
4 Number of part flows, maximum 12

Page 16 www.jahns-hydraulik.de
HYDRAULIK
Gear flow-divider (aluminium housing) MTO Size 2
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate
the total length with a difference of B each section. MTO-..-..-G
Weight: MTO-..-8-G 2,1 kg/section
MTO-..-14-G 2,6 kg/section
MTO-..-31-G 3,5 kg/section

Connections
E1 to E2 Input MTO-..-..-A..
A1 to A4 Output, divided flow
T, NS Tank and low-pressure-feeding Weight: MTO-..-8-A 2,7 kg/section
MTO-..-14-A 3,4 kg/section
MTO-..-31-A 4,5 kg/section

Circuit according DIN ISO 1219

Type A1-4 E1-2 T/NS B C D F G H


MTO-..-8 70 57,1 303 46,5 379,2 84,6
G1/2" G3/4"
MTO-..-14 G1/2" 88 75,1 375 55,5 451,2 93,6
MTO-..-31 G3/4" G1" 115 102,1 483 69,0 559,2 107,1

www.jahns-hydraulik.de Page 17
HYDRAULIK
MTO Gear flow-divider (cast iron housing) Size 3

Displacement min. flow max. flow Continue Peak


Type per section per section per section pressure pressure
(cm3/U) (l/min) (l/min) (bar) (bar)

Size 3
MTO-..-25 24,9 12 66 270 290
MTO-..-35 34,3 16 82 260 285
MTO-..-55 54,5 27 98 260 285
MTO-..-80 78,7 40 140 260 285

Size 4 Page 22, 23


MTO-..-110 105,4 50 200 270 290
MTO-..-150 149,7 80 220 235 250

Order codes Example: MTO-4-55-EA7 4-section flow-divider with all sections of 54,5 cm³/rev.

G Threated connection
GB Threated connection, for valve block assembly
E Inlet block
A7 Outlet block, design series 7
Displacement per section
Number of section, maximum 8

Restrictions in the use of other operating fluids than mineral oil


max. pressure max. revs
Type Fluid temperatur range seals
(bar) (rev/min)
HFC water glycol 160 1300 -20 bis 60°C *
HFD phosphate esther 160 1500 -10 bis 60°C FKM
* Perbunan oder FKM according to the HFC manufacturer's recommendation

Page 18 www.jahns-hydraulik.de
HYDRAULIK
MTO Gear flow-divider (cast iron housing) Size 3 EA7

The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 167,5 mm each section. MTO-..-..-G
Connections Weight: 17 kg/section
E G1" Input
A1 to A4 G1" Output, divided flows

Connections
E G1 1/4" Input MTO-..-..-EA7
A1 to A4 G1 1/4" Output, divided flows
T, NS G1/2" Tank and low-pressure-feeding Weight: 22 kg/section
M1 to M4 G3/4" Measuring port for each section

Circuit according DIN ISO 1219

Type A B C D
MTO-..-35 130,0 37,5 110,0 471,5
MTO-..-55 124,5 43,0 104,5 488,5
MTO-..-80 109,0 58,5 89,0 504,0

www.jahns-hydraulik.de Page 19
HYDRAULIK
Gear flow-divider (cast iron housing) MTO Size 3

Displacement min. flow max. flow Continue Peak


Type per section per section per section pressure pressure
(cm3/U) (l/min) (l/min) (bar) (bar)

Size 3
MTO-..-25 24,9 12 66 270 290
MTO-..-35 34,3 16 82 260 285
MTO-..-55 54,5 27 98 260 285
MTO-..-80 78,7 40 140 260 285

Size 4 Page 22, 23


MTO-..-110 105,4 50 200 270 290
MTO-..-150 149,7 80 220 235 250

Order codes Example: MTO-4-55-EA9 4-section flow-divider with all sections of 54,5 cm³/rev.

G Threated connection
GB Threated connection, for valve block assembly
E Inlet block
A9 Outlet block, design series 9
Displacement per section
Number of section, maximum 8

Restrictions in the use of other operating fluids than mineral oil


max. pressure max. revs
Type Fluid temperatur range seals
(bar) (rev/min)
HFC water glycol 160 1300 -20 bis 60°C *
HFD phosphate esther 160 1500 -10 bis 60°C FKM
* Perbunan oder FKM according to the HFC manufacturer's recommendation

Page 20 www.jahns-hydraulik.de
HYDRAULIK
Gear flow-divider (cast iron housing) MTO Size 3 EA9
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 167,5 mm each section. MTO-..-..-G
Connections Weight: 17 kg/section
E G1" Input
A1 to A4 G1" Output, divided flows

Connections
E G1 1/4" Input MTO-..-..-EA9
A1 to A4 G1 1/4" Output, divided flows
T, NS G1 1/4" Tank and low-pressure-feeding Weight: 36 kg/section
M1 to M4 G1/4" Measuring port for each section

Circuit according DIN ISO 1219

Type A B C D
MTO-..-35 126,0 41,5 104,5 492,5
MTO-..-55 124,5 43,0 104,5 505,5
MTO-..-80 109,0 58,5 89,0 521,0

www.jahns-hydraulik.de Page 21
HYDRAULIK
MTO Gear flow-divider (cast iron housing) Size 4

Displacement min. flow max. flow Cotinue Peak


Type per section per section per section pressure pressure
(cm3/U) (l/min) (l/min) (bar) (bar)

Size 3 Page 18, 21


MTO-..-25 24,9 12 66 270 290
MTO-..-35 34,3 16 82 260 285
MTO-..-55 54,5 27 98 260 285
MTO-..-80 78,7 40 140 260 285

Size 4
MTO-..-110 105,4 50 200 270 290
MTO-..-150 149,7 80 220 235 250

Order codes
Example: MTO-4-110-EA9 4-section flow-divider with all sections of 105,4 cm³/rev.

S SAE 1 1/2" 3000 psi


SB SAE 1 1/2" 3000 psi, for valve block assembly
E Inlet block
A9 Outlet block, design series 9
Displacement per section
Number of section, maximum 8

Restrictions in the use of other operating fluids than mineral oil


max. pressure max. revs
Type Fluid temperatur range seals
(bar) (rev/min)
HFC water glycol 160 1300 -20 bis 60°C *
HFD phosphate esther 160 1500 -10 bis 60°C FKM
* Perbunan oder FKM according to the HFC manufacturer's recommendation

Page 22 www.jahns-hydraulik.de
HYDRAULIK
MTO Gear flow-divider (cast iron housing) Size 4
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of B each section. MTO-..-...-S
Connections
Weight: 25 kg/section
E1 to E4 SAE1 1/2" 3000 psi, Input
A1 to A4 SAE1 1/2" 3000 psi, Output, divided flows

Connections
E1 to E2 SAE 2" 6000 psi, Input
MTO-..-...-EA9
A1 to A4 SAE1 1/2" 6000 psi, Output, divided flows
T, NS G1 1/4" Tank and low-pressure-feeding Weight: 56 kg/section
M1 to M4 G1/4" Measuring port for each section

Circuit according DIN ISO 1219

Typ B C D F G H
MTO-..-110 171 117 683,5 99,5 92 419
MTO-..-150 187 133 747,5 102,5 95 387

www.jahns-hydraulik.de Page 23
HYDRAULIK
HTO Gear flow-divider (cast iron housing) Size 3

Displacement min. flow max. flow Continue Peak


Type per section per section per section pressure pressure
(cm3/U) (l/min) (l/min) (bar) (bar)

Size 3
HTO-..-35 34,3 12 82 320 380
HTO-..-80 78,7 27 140 320 380

Size 4 Page 26, 27


HTO-..-110 105,4 50 200 320 380
HTO-..-150 149,7 80 220 320 380

Order codes Example: HTO-4-35-FI 4-section flow-divider with all sections of 34,3 cm³/rev.

F with feet
I with valves
V viton seals
Displacement per section
Number of section, maximum 12

Restrictions in the use of other operating fluids than mineral oil


max. pressure max. revs
Type Fluid temperatur range seals
(bar) (rev/min)
HFC water glycol 160 1300 -20 bis 60°C *
HFD phosphate esther 160 1500 -10 bis 60°C FKM
* Perbunan oder FKM according to the HFC manufacturer's recommendation

Page 24 www.jahns-hydraulik.de
HYDRAULIK
HTO Gear flow-divider (cast iron housing) Size 3
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 167,5 mm each section. HTO-..-..-FI
Weight: 40 kg/section

Feet can be placed from 167,5 mm

Circuit according DIN ISO 1219

Connections
E1 to E4 SAE NW32 420 bar (1 1/4", 6000 psi), Input
A1 to A4 SAE NW25 420 bar (1", 6000 psi), Output, divided flows
T, NS G3/4" Tank and low-pressure-feeding
ME G1/4" Measuring, input
M1 to M4 G1/4" Measuring port for each section, output

www.jahns-hydraulik.de Page 25
HYDRAULIK
HTO Gear flow-divider (cast iron housing) Size 4

Displacement min. flow max. flow Cotinue Peak


Type per section per section per section pressure pressure
(cm3/U) (l/min) (l/min) (bar) (bar)

Size 3 Page 24, 25


HTO-..-35 34,3 16 82 320 380
HTO-..-80 78,7 40 140 320 380

Size 4
HTO-..-110 105,4 50 200 320 380
HTO-..-150 149,7 80 220 320 380

Order codes
Example: HTO-4-110-FI 4-section flow-divider with all sections of 105,4 cm³/rev.

F with feet
I with valves
V viton seals

Displacement per section


Number of section, maximum 12

Restrictions in the use of other operating fluids than mineral oil


max. pressure max. revs
Type Fluid temperatur range seals
(bar) (rev/min)
HFC water glycol 160 1300 -20 bis 60°C *
HFD phosphate esther 160 1500 -10 bis 60°C FKM
* Perbunan oder FKM according to the HFC manufacturer's recommendation

Page 26 www.jahns-hydraulik.de
HYDRAULIK
HTO Gear flow-divider (cast iron housing) Size 4
The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the
total length with a difference of 194 mm each section. HTO-..-...-FI
Weight: 75 kg/section

Feet can be placed from 194 mm

Circuit according DIN ISO 1219

Connections
E1 to E2 SAE NW40 420 bar (1 1/2", 6000 psi), Input
A1 to A4 SAE NW40 420 bar (1 1/2", 6000 psi), Output, divided flows
T, NS G1" Tank and low-pressure-feeding
ME G1/4" Measuring, input
M1 to M4 G1/4" Measuring port for each section, output

www.jahns-hydraulik.de Page 27
HYDRAULIK
Radial piston flow divider MT-GM

Displacement Flow per section Pressure Max poiwer

Type per section continuous maximum continuous intermittend per section

cm3/rev l/min l/min bar bar kW

MT-GM1 100/100 99 35 50 240 300 24


MT-GM1 175/175 172 70 100 240 300 30
MT-GM2 350/350 347 120 175 240 300 45
MT-GM2 500/500 493 145 210 240 300 45
MT-GM3 800/800 792 235 280 240 300 60
MT-GM5 1800/1800 1816 340 430 240 300 90
MT-GM6 3000/3000 3041 430 550 240 300 120
Complete drawings of the assembled units of different sizes to be used as pressure-multipliers or flow-dividers are available
upon request.

Order Codes Example: MT-GM1-100/100-FG


G Threated connection, see page 8
F Feet, standard-supply without feet
EA Inlet and outletblock
Displacement of each section,see page 11
GM1 Size

MT-GM1... / ...-FG
Weight: 70 kg

Connections
E1 - E2 G1" Input, to be connected together
A1 - A2 G1" Output, section-flows
L1 - L2 G1/4" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !

Page 28 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MT-GM

MT-GM2... / ...-FG
Weight: 130 kg

Connections
E1 - E2 G1" Input, to be connected together
A1 - A2 G1" Output, section-flows
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !

MT-GM3... / ...-FG
Weight: 215 kg

Connections
E1 - E2 G1" Input, to be connected together
A1 - A2 G1" Output, section-flows
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !

www.jahns-hydraulik.de Page 29
HYDRAULIK
Radial piston flow divider MT-GM

MT-GM5... / ...-FS
Weight: 425 kg

Connections
E1 - E2 SAE 1 1/2" Input, to be connected together
A1 - A2 SAE 1 1/2" Output, section-flows
L1 - L2 G1/2" Drain-ports
Important: both ports have to be connected to the tank !

MT-GM6... / ...-FS
Weight: 550 kg

Connection
E1 - E2 SAE 1 1/2" Input, to be connected together
A1 - A2 SAE 1 1/2" Output, section-flows
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !

Page 30 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MT-GM

Displacement Flow per section Betriebsdruck Max poiwer

Typ per section continuous maximum continuous intermittend per section

cm3/rev. l/min l/min bar bar kW

MT-GM1 100/100 99 35 50 240 300 24


MT-GM1 175/175 172 70 100 240 300 30
MT-GM2 350/350 347 120 175 240 300 45
MT-GM2 500/500 493 145 210 240 300 45
MT-GM3 800/800 792 235 280 240 300 60
MT-GM5 1800/1800 1816 340 430 240 300 90
MT-GM6 3000/3000 3041 430 550 240 300 120
Complete drawings of the assembled units of different sizes to be used as pressure-multipliers or flow-dividers are available
upon request.

Order Codes Example: MT-GM1-100/100-FEA


G Threated connection, see page 8
F Feet, standard-supply without feet
EA Inlet and outletblock
Displacement of each section
GM1 Size

MT-GM1... / ...-FEA
Weight: 90 kg

Circuit according DIN ISO 1219

Connection
E1 - E2 G1 1/4" Input, alternatively
A1 - A2 G1" Output, section-flows
L1 - L2 G1/4" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G3/8" Tank- and low-pressure-feeding
M1 - M2 G3/8" Measuringport for each sections

www.jahns-hydraulik.de Page 31
HYDRAULIK
Radial piston flow divider MT-GM

MT-GM2... / ...-FEA
Weight: 150 kg

Circuit according DIN ISO 1219

Connections
E1, E2 G1 1/4" Input, alternatively
A1, A2 G1" Output, section-flows
L1, L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G3/8" Tank- and low-pressure-feeding
M1 , M2 G3/8" Measuringport for each sections

MT-GM3-... / ...-FEA
Weight: 240 kg

Circuit according DIN ISO 1219

Connections
E1, E2 NW 40 / G1 1/4" Input, alternatively
A1, A2 G1 1/4" Output, section-flows
L1, L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G3/4" Tank- and low-pressure-feeding
M1, M2 G1/2" Measuringport for each sections

Page 32 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MT-GM
Connections
E1 - E2 SAE 1 1/2" Input, to be connected together
MT-GM5... / ...-FEA
A1 - A2 SAE 1 1/2" Output, section-flows Weight: 480 kg
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G1 1/2" Tank- and low-pressure-feeding,to be connected together
M1, M2 G1/4" Measuringport

Circuit according DIN ISO 1219

Connections
E1 - E2 SAE 1 1/2" Input, to be connected together
MT-GM6... / ...-FEA
A1 - A2 SAE 1 1/2" Output, section-flows Weight: 725 kg
L1 - L2 G1/2" Drain-ports, drain pressure max. 2 bar
Important: both ports have to be connected to the tank !
T, NS G1 1/2" Tank- and low-pressure-feeding, to be connected together
M1, M2 G1/4" Measuringport

Circuit according DIN ISO 1219

www.jahns-hydraulik.de Page 33
HYDRAULIK
Radial piston flow divider MTL

Displacement Flow per section Pressure Max. power


per section continuous intermittend continuous intermittend per section
Type (cm³/rev) (l/min) (l/min) (bar) (bar) (kW)

MTL../ 29 30,2 28 40 240 300 14


MTL../ 42 42,7 45 65 240 300 20
MTL../ 70 69,9 63 90 240 300 30
MTL../ 108 108,4 95 135 240 300 45
MTL../ 170 170,9 110 160 240 300 55
MTL../ 270 271,4 175 250 240 300 75

Complete drawings of the series MTL-2/29 to MTL-12/270 of different sizes are available upon request.

Order codes Example: MTL-4/29-EA

G Threated connection
E Inlet block, see pages 32, 33
A Outlet block, see pages 32, 33
29 Displacement of each section
4 Number of sections

Connections
MTL ../ 29-G A1 to A4 or B1 to B4 G3/4" Input, to be connected together
MTL ../ 42-G B1 to B4 or A1 to A4 G3/4" Output, section-flows
L G1/2" Drain-ports, drain pressure max. 10 bar

Feet can be placed from 130 mm

The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 130 mm each section.

Page 34 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MTL
Connections
A1 to A4 or B1 to B4 G1/4" Input, to be connected together
MTL../ 70-G
B1 to B4 or A1 to A4 G1/4" Output, section-flows MTL../ 108-G
L G3/4" Drain-ports, drain pressure max. 10 bar

Feet can be placed from 155 mm

The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 155 mm each section.

Connections MTL../ 170-G


A1 to A4 or B1 to B4 G1/4" Input, to be connected together
B1 to B4 or A1 to A4 G1/4" Output, section-flows MTL../ 270-G
L G3/4" Drain-ports, drain pressure max. 10 bar

Feet can be placed from 255 mm

The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 255 mm each section.

www.jahns-hydraulik.de Page 35
HYDRAULIK
Radial piston flow divider MTL

Displacement Flow per section Pressure Max. power


per section continuous intermittend continuous intermittend per section
Type (cm³/rev) (l/min) (l/min) (bar) (bar) (kW)

MTL../ 29 30,2 28 40 240 300 14


MTL../ 42 42,7 45 65 240 300 20
MTL../ 70 69,9 63 90 240 300 30
MTL../ 108 108,4 95 135 240 300 45
MTL../ 170 170,9 110 160 240 300 55
MTL../ 270 271,4 175 250 240 300 75

Complete drawings of the series MTL-2/29 to MTL-12/270 of different sizes are available upon request.

Order codes Examle: MTL-4/29-EA

G Threated connection
E Inlet block
A Outlet block
29 Displacement of each section
4 Number of sections

MTL../29-EA Connections circuit according DIN ISO 1219


E G1 1/4" Input
MTL../42-EA A1 to A4 G3/4" Output, divided flows
L G1/2" Drain port,
drain-pressure max. 10 bar
T, NS G3/8" Tank and low-pressure-feeding
M1 to M4 G1/4" Measuring port for each section

Feet can be placed from 130 mm

The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 130 mm each section.
Weight: MTL-../29-EA and MTL-../42-EA 36 kg/section

Page 36 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider MTL
Connections circuit according DIN ISO 1219
E G1 1/2" Input
MTL../ 70-EA2
A1 to A4 G1 1/4" Output, divided flows MTL../ 108-EA2
L G3/4" Drain port,
drain-pressure max. 10 bar
T, NS G1 1/4" Tank and low-pressure-feeding
M1 to M4 G1/4" Measuring port for each section

Feet can be placed from 155 mm

The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 155 mm each section.
Weight: MTL-../70-EA and MTL-../108-EA 74 kg/section

circuit according DIN ISO 1219


Connections MTL../ 170-EA
E G2" Input
A1 to A4 G1 1/2" Output, divided flows MTL../ 270-EA
L G3/4" Drain port,
drain-pressure max. 10 bar
T, NS G3/4" Tank and low-pressure-feeding
M1 to M4 G1/4" Measuring port for each section

Feet can be placed from 225 mm

The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 255 mm each section.
Weight: MTL-../170-EA and MTL-../270-EA 167 kg/section

www.jahns-hydraulik.de Page 37
HYDRAULIK
Radial piston flow divider STL

Displacement Flow per section Pressure Max. power


per section continuous intermittend continuous intermittend per section
Type (cm³/rev) (l/min) (l/min) (bar) (bar) (kW)

STL..- 220 494,1 220 280 240 300 100


STL..- 320 722,2 320 400 240 300 125

Complete drawings of the series STL-2-220 to STL-12-320 of different sizes are available upon request.

Order codes Examle: STL-4-320-EA

S Flange connection, SAE


E Inlet block
A Outlet block
320 Displacement of each section
4 Number of sections

Page 38 www.jahns-hydraulik.de
HYDRAULIK
Radial piston flow divider STL
Connections
E1 to E4 SAE NW50, 6000 psi Input
STL..- 220-S
A1 to A4 SAE NW50, 6000 psi Output, divided flows STL..- 320-S
L G1" Drain port,
drain-pressure max. 10 bar

The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 280 mm each section.
Weight: STL-..-220-S and STL-..-320-S 240 kg/section

Connections
E1 to E2 SAE 2 1/2", 6000 psi Input
circuit according DIN ISO 1219 STL..- 220-EA
A1 to A4 SAE NW50, 6000 psi Output, divided flows STL..- 320-EA
L G1" Drain port,
drain-pressure max. 10 bar
T, NS SAE NW50, 3000 psi Tank and low-pressure-feeding
M1 to M4 G1/4" Measuring port for each section

The drawing shows a 4-section flow-divider. Using more or less sections, you have to calculate the total length with a
difference of 280 mm each section.
Weight: STL-..-220-EA and STL-..-320-EA 296 kg/section

www.jahns-hydraulik.de Page 39
HYDRAULIK
Components for hydraulics and process technology

Jahns-Regulatoren GmbH home address


Postbox 10 09 52 Sprendlinger Landstraße 150 http://www.jahns-hydraulik.de
D 63009 Offenbach D 63069 Offenbach info@jahns-hydraulik.de
telephon +49/(0)69/84 84 77-0 telefax +49/(0)69/84 84 77 25

You might also like