Liebherr Lab
Liebherr Lab
Liebherr Lab
Contents
Heavy-duty refrigerators and freezers 06
Accessories 35
02 03
Good reasons
to choose Liebherr
Liebherr research and laboratory freezers Highly efficient with low energy consumption: All laboratory appliances are designed Hygiene plays a special role in research To meet the most stringent requirements Durability and reliability are given top
provide constant refrigeration performance the precise electronic controller, the according to the ISO 60068-3 and in the laboratory. That is why Liebherr regarding reliability and accurate priority in the material selection and
even in extreme climate conditions. The dynamic refrigeration system and highly standard with regard to maximum appliances are equipped with moulded temperature consistency in laboratory development of Liebherr laboratory
use of ultra-modern components, efficient effective insulation guarantee low operating temperature stability. They are specially inner liners with large radii that are easy applications, Liebherr appliances are appliances. The exemplary quality and
and environmentally-friendly refrigerants costs and are eco-friendly as well. The constructed for intensive professional to clean. Flush seals prevent condensation equipped with many useful features: easy usability of the appliances are
as well as precise controls ensures that high quality of the appliances guarantees use and feature a very sturdy design – and the accumulation of dirt and dust. a visual and audible door alarm alerts ensured by elaborate tests. The heavy-
samples, chemicals and research materials long life and reliable operation and with highest-quality materials and perfect Sturdy castors also allow easy cleaning the user to undesired temperature duty models with top-mounted units have
are stored optimally. Optional documentation provides for economic and ecological workmanship right down to the smallest of the floor space underneath the deviations. The appliances can be all refrigeration components on the top
software continuously logs the temperature sustainability in laboratory and research detail. The exemplary quality of the appliances. connected via the volt-free contact to of the cabinet. This allows easy service
profile – and if required, warning systems applications. appliances is ensured by elaborate an external remote warning system – access and full use of the refrigerated
alert the user when defined temperature tests. All electronic and refrigeration and up to 20 appliances can be compartment. The door remains open
limits are exceeded. components fulfill Liebherr’s stringent networked with a monitoring and alarm at 90° and is self-closing at less than
specifications to form a well-balanced system via the serial interface RS 485. 60° for convenient use. And the sturdy
and therefore reliable system – ideal In case of a power failure, the electronic inner liners are easy to clean and allow
for research and laboratory. controller (in LKPv and LGPv) is powered variable adjustment of the grid shelves.
by a battery for 72 hours to prevent
data loss. The calibration option allows
precise temperature control adapted to
specific applications.
04 05
Heavy-duty refrigerators and freezers
The integrated data logger includes a After a refrigerator or freezer door has been opened, a vacuum is built
min/max temperature memory function. up by air exchange – with the effect that the door is hard to reopen
immediately afterwards. The integrated pressure relief valve ensures
that the vacuum is quickly equalised so that the door can easily be reopened.
These appliances have an access port The laboratory appliances are equipped with a volt-free contact
(7.0 mm in diameter) in the ceiling for alarm forwarding to an external warning system.
area to enable connection of an
independent temperature sensor.
Maximum temperature stability in the interior is ensured by the dynamic cooling
system with double ventilation, in conjunction with optimal routing of the air flow.
In case of power failure, the electronic controller is immediately powered by an Visual and audible door alarms alert
integrated 12 V battery. As a result, the integrated memory continues to log the user if the door is open for
the internal temperatures without interruption for another 72 hours. longer than 1 minute.
To increase the net capacity of the inner liner, functional parts like fans and The calibration function enhances validation and enables
evaporators are located outside the refrigerator compartment to save space. temperature control adapted to the specific application.
The practical door remains open The LKPv and LGPv ranges come with
at 90 ° and is self-closing at castors as standard to allow versatile
less than 60 ° for convenient use. use depending on the available space
and convenient cleaning also underneath
the appliances.
LKPv 6520
0
06 07
7
Heavy-duty refrigerators and freezers
+0.5°C
72 hours
Integrated alarm systems. Cal. 5.0°C +0.5°C
A visual and audible door alarm alerts the user to temperature Mains-independent power supply of the electronic controller.
deviations. An alarm is also raised if the door is open for longer In case of power failure, the electronic controller is powered
than one minute or in the event of power failure. by a battery. The memory continues to log the internal
temperature for another 72 hours.
Integrated digital controller. Integrated data memory. Accurate 1-point calibration. If external alarm and monitoring systems have been
The intuitive controller with integrated real-time clock allows The min/max temperature memory function stores the The digital controller includes a calibration function for connected, then data transfer to these is also maintained.
the temperature to be set to 1/10°C accuracy. The large values for up to 41 days. In addition the alarm memory extremely accurate temperature control and display. This
display allows improved temperature visibility at a glance. function records the last 3 alarm conditions with alarm permits compensation between the set temperature and External temperature sensor.
The keyboard is dirt resistant and easy to clean – to meet type, date and time, duration and maximum temperature. the actual internal temperature. Positive or negative changes The laboratory appliances have an access port (diameter
the most stringent hygiene requirements in the laboratory. to the correction value can be made in steps of 0.1 K. 7.0 mm) in the appliance ceiling which allows a temperature
sensor to be positioned in the interior.
30 min 10 min
Electric defrost Hot gas defrost
08 09
Heavy-duty refrigerators Heavy-duty freezers
Heavy-duty refrigerators LKPv 1423 LKPv 8420 LKPv 6523 LKPv 6520 LGPv 1420 LGPv 8420 LGPv 6520
and freezers MediLine MediLine MediLine MediLine MediLine MediLine MediLine
Gross capacity 1361 litre 856 litre 597 litre 597 litre 1361 litre 856 litre 597 litre
Exterior dimensions in mm (w / d / h) 1430 / 830 / 2150 790 / 980 / 2150 700 / 830 / 2150 700 / 830 / 2150 1430 / 830 / 2150 790 / 980 / 2150 700 / 830 / 2150
Interior dimensions in mm (w / d / h) 1236 / 650 / 1500 620 / 850 / 1550 533 / 650 / 1500 533 / 650 / 1550 1236 / 650 / 1550 620 / 850 / 1550 533 / 650 / 1550
Energy consumption in 365 days ¹ 820 kWh 603 kWh 571 kWh 497 kWh 2654 kWh 1739 kWh 1367 kWh
Ambient temperature range +10°C to +40°C +10°C to +40°C +10°C to +40°C +10°C to +40°C +10°C to +35°C +10°C to +35°C +10°C to +35°C
Refrigerant R 290 R 290 R 290 R 290 R 290 R 290 R 290
Sound power level 58 dB(A) 58 dB(A) 58 dB(A) 58 dB(A) 60 dB(A) 60 dB(A) 60 dB(A)
Voltage / Connection rating 220 – 240V~ / 3.0 A 220 – 240V~ / 2.0 A 220 – 240V~ / 2.0 A 220 – 240V~ / 2.0 A 220 – 240V~ / 4.5 A 220 – 240V~ / 4.0 A 220 – 240V~ / 4.0 A
Cooling system forced-air forced-air forced-air forced-air forced-air forced-air forced-air
Defrost automatic automatic automatic automatic automatic automatic automatic
Set temperature range 0°C to +16°C −2°C to +16°C 0°C to +16°C −2°C to +16°C −9°C to −26°C −9°C to −35°C ² −9°C to −35°C ²
Gradient * / max. fluctuation ** 3.8°C / 3.9°C 2.1°C / 1.8°C 2.4°C / 1.6°C 1.8°C / 1.0°C 4.3°C / 6.7°C 4.5°C / 5.7°C 2.9°C / 3.6°C
External cabinet finish steel / white steel / white steel / white steel / white steel / white steel / white steel / white
Door / lid material glass door steel glass door steel steel steel steel
Internal liner material 304-grade stainless steel 304-grade stainless steel 304-grade stainless steel 304-grade stainless steel 304-grade stainless steel 304-grade stainless steel 304-grade stainless steel
Type of control electronic controller electronic controller electronic controller electronic controller electronic controller electronic controller electronic controller
Temperature display external digital external digital external digital external digital external digital external digital external digital
Power failure alarm immediately upon power failure for 72hrs immediately upon power failure for 72hrs immediately upon power failure for 72hrs immediately upon power failure for 72hrs immediately upon power failure for 72hrs immediately upon power failure for 72hrs immediately upon power failure for 72hrs
Fault: warning signal visual and audible visual and audible visual and audible visual and audible visual and audible visual and audible visual and audible
Interface / Volt-free alarm contact RS 485 / yes RS 485 / yes RS 485 / yes RS 485 / yes RS 485 / yes RS 485 / yes RS 485 / yes
Interior light LED lighting, with separate switch LED lighting, with separate switch
Adjustable shelves 8 4 4 4 8 4 4
Usable shelf area in mm (w / d) 1236 / 640 620 / 800 533 / 650 533 / 650 1236 / 640 620 / 800 533 / 650
Shelf material wire shelves plastic-coated wire shelves plastic-coated wire shelves plastic-coated wire shelves plastic-coated wire shelves plastic-coated wire shelves plastic-coated wire shelves plastic-coated
Shelf loading 60 kg 60 kg 60 kg 60 kg 60 kg 60 kg 60 kg
Castors castors with brake at the front, castors with brake at the front, castors with brake at the front, castors with brake at the front, castors with brake at the front, castors with brake at the front, castors with brake at the front,
castors at the rear fixed castors at the rear fixed castors at the rear fixed castors at the rear castors at the rear fixed castors at the rear fixed castors at the rear
Handle full-length integrated handle full-length integrated handle full-length integrated handle full-length integrated handle full-length integrated handle full-length integrated handle full-length integrated handle
Lock fitted fitted fitted fitted fitted fitted fitted
Self-closing door yes yes yes yes yes yes yes
Door hinges left hand / right hand right, reversible on site right, reversible on site right, reversible on site left hand / right hand right, reversible on site right, reversible on site
Gross / net weight 271 / 226 kg 183 / 152 kg 167 / 141 kg 158 / 132 kg 262 / 219 kg 189 / 157 kg 165 / 138 kg
Accessories
Shelf, plastic-coated 7112393 7113643 7112393 7112393 7112393 7113643 7112393
U-shaped trayslide, right 9001761 9005089 9001761 9001761 9001761 9005089 9001761
U-shaped trayslide, left 9001757 9005077 9001757 9001757 9001757 9005077 9001757
Foot pedal opener 9590639 9590659 9590659 9590659 9590639 9590659 9590659
RS 485 / RS 232 adapter, data log software 9590387 9590387 9590387 9590387 9590387 9590387 9590387
NTC product temperature sensor 9590407 9590407 9590407 9590407 9590407 9590407 9590407
Also available as LKPv 1420 with solid doors
1 Measured at +25°C ambient temperature and +5°C set temperature for fridges and -20°C for freezers * Gradient as defined in EN 60068-3: the difference between the warmest and coldest average measurements, increased by their expanded uncertainty,
10 2 The temperature range is valid at a maximum ambient temperature of +30°C throughout the duration. 11
** Max. fluctuation as per EN 60068-3: greatest fluctuation value determined throughout the duration of measurements.
Laboratory refrigerators, freezers and fridge-freezer combination with electronic controls
The advantages at a glance The integrated lock is exceedingly sturdy and protects
the stored products against unauthorised access.
Volt-free contact for forwarding alarms The precise electronic controller with digital temperature
to an external remote warning system. display allows accurate temperature setting to 1/10°C.
An integrated data memory logs the last three temperature
alarms and power failures, together with the time, date and
duration of the alarm. The respective data can be recalled using
the AlarmLog function and read on the display panel.
The commercial-grade moulded polystyrol Laboratory refrigerators LKv 3913 and LKUv 1613 with a glass door feature
inner liner is exceptionally easy to clean and an efficient LED interior light with a separate switch.
enables optimum hygiene.
The sturdy, plastic-coated grid shelves 1-point calibration for accurate temperature control.
have a loading capacity of up to 45 kg, This permits compensation between the set temperature
are easily adjustable in height and can be and the actual internal temperature.
removed at a door opening angle of 90 °.
+5°
Reversible door hinges in the LKv, LKUv, LGv and LCv models
enable individual adaption to space conditions.
The door seals can also be easily replaced as required.
LLKv 3913
12 13
3
Laboratory refrigerators, freezers and fridge-freezer combination with electronic controls Laboratory refrigerators with electronic controls
Total gross / net capacity 583 / 437 litre 360 / 344 litre 360 / 344 litre
Exterior dimensions in mm (w / d / h) 747 / 750 / 1844 597 / 615 / 1840 597 / 615 / 1840
Interior dimensions in mm (w / d / h) 634 / 538 / 1500 440 / 435 / 1635 440 / 435 / 1635
Energy consumption in 365 days ¹ 438 kWh 480 kWh 309 kWh
External temperature and alarm documentation. Ambient temperature range +10°C to +35°C +10°C to +35°C +10°C to +35°C
The laboratory appliances are equipped with a volt-free contact Maximum temperature consistency. Refrigerant R 600a R 600a R 600a
for alarm forwarding to an external remote warning system, The dynamic cooling system in conjunction with the precise Sound power level 52 dB(A) 48 dB(A) 48 dB(A)
Voltage / Connection rating 220 – 240V~ / 1.0 A 220 – 240V~ / 1.5 A 220 – 240V~ / 1.5 A
as well as with a serial interface RS 485 which enables central electronic controller ensures maximum temperature stability.
Cooling system forced-air forced-air forced-air
documentation of temperature profiles and alarm events. All laboratory appliances are designed according to the
Defrost automatic automatic automatic
LTM documentation software is optionally available. ISO 60068 -3 standard with regard to optimum temperature Set temperature range +3°C to +16°C +3°C to +16°C +3°C to +16°C
consistency. Gradient * / max. fluctuation ** 3.8°C / 3.1°C 5.6°C / 4.7°C 4.1°C / 3.6°C
External cabinet finish steel / white steel / white steel / white
Door / lid material steel glass door steel
Internal liner material commercial grade moulded polystyrol commercial grade moulded polystyrol commercial grade moulded polystyrol
Type of control electronic controller electronic controller electronic controller
Temperature display external digital external digital external digital
Power failure alarm when mains power return when mains power return when mains power return
Fault: warning signal visual and audible visual and audible visual and audible
Interface / Volt-free alarm contact RS 485 / yes RS 485 / yes RS 485 / yes
Interior light LED lighting, with separate switch
Adjustable shelves 5 5 5
Usable shelf area in mm (w / d) 634 / 518 440 / 420 440 / 420
+ 2 ˚C Shelf material wire shelves plastic-coated wire shelves plastic-coated wire shelves plastic-coated
Shelf loading 60 kg 45 kg 45 kg
Handle ergonomic slimline handle ergonomic slimline handle ergonomic slimline handle
Lock fitted fitted fitted
Self-closing door yes yes yes
Door hinges right, reversible on site right, reversible on site right, reversible on site
Gross / net weight 98 / 91 kg 88 / 82 kg 70 / 65 kg
Accessories
Shelf, plastic-coated 7113485 7112313 7112313
Evaporator cover, white 9590241 9590241
Safety thermostat. External temperature sensor. Adjustable legs 9590231 9590231
RS 485 / RS 232 adapter, data log software 9590387 9590387 9590387
The appliances with electronic controllers are equipped with The laboratory appliances have an access port (diameter 10
Additional lock barrels (up to 10) on request on request
an additional safety thermostat to prevent temperatures mm) on the rear which allows the temperature sensor to be
Foot pedal opener 9094579
dropping below +2°C and to protect sensitive products in the positioned in the interior. Roller bars 9590380 9590380
event of a fault.
1 Measured at +25°C ambient temperature and +5°C set temperature * Gradient as defined in EN 60068-3: the difference between the warmest and coldest average measurements, increased by their expanded uncertainty,
14 for fridges and -20°C for freezers throughout the duration. 15
** Max. fluctuation as per EN 60068-3: greatest fluctuation value determined throughout the duration of measurements.
Laboratory refrigerators and freezers with electronic controls Laboratory fridge-freezer combination with electronic controls
Laboratory refrigerators and LKUv 1613 LKUv 1610 LGv 5010 Laboratory fridge-freezer combination LCv 4010
freezers with electronic controls MediLine MediLine MediLine with electronic controls MediLine
Total gross / net capacity 141 / 130 litre 141 / 130 litre 478 / 337 litre Total gross / net capacity fridge compartment 254 / 240 litre
Exterior dimensions in mm (w / d / h) 597 / 615 / 825 597 / 615 / 825 747 / 750 / 1844 Total gross / net capacity freezer compartment 107 / 105 litre
Interior dimensions in mm (w / d / h) 440 / 435 / 670 440 / 435 / 670 602 / 520 / 1224 Exterior dimensions in mm (w / d / h) 597 / 615 / 2003
Energy consumption in 365 days ¹ 369 kWh 273 kWh 1245 kWh Interior dimensions in mm (w / d / h) fridge compartment 440 / 441 / 1105
Ambient temperature range +10°C to +35°C +10°C to +35°C +16°C to +35°C Interior dimensions in mm (w / d / h) freezer compartment 431 / 435 / 597
Refrigerant R 600a R 600a R 290 Energy consumption in 365 days ¹ 657 kWh
Sound power level 47 dB(A) 47 dB(A) 55 dB(A) Ambient temperature range +10°C to +35°C
Voltage / Connection rating 220 – 240V~ / 1.0 A 220 – 240V~ / 1.0 A 220 – 240V~ / 3.0 A Refrigerant R 600a
Cooling system forced-air forced-air forced-air Sound power level 52 dB(A)
Defrost automatic automatic automatic Voltage / Connection rating 220 – 240V~ / 1.5 A
Set temperature range +3°C to +16°C +3°C to +16°C −9°C to −35°C Cooling system fridge / freezer comp. forced-air / static
Gradient * / max. fluctuation ** 5.1°C / 4.9°C 4.3°C / 4.6°C 5.8°C / 4.9°C Defrost fridge / freezer comp. automatic / manual
External cabinet finish steel / white steel / white steel / white Set temperature range fridge / freezer comp. +3°C to +16°C / −9°C to −30°C
Door / lid material glass door steel steel Gradient * fridge / freezer comp. 5.2°C / 7.9°C
Internal liner material commercial grade moulded polystyrol commercial grade moulded polystyrol commercial grade moulded polystyrol Max. fluctuation ** fridge / freezer comp. 5.7°C / 5.5°C
Type of control electronic controller electronic controller electronic controller External cabinet finish steel / white
Temperature display external digital external digital external digital Door / lid material steel
Power failure alarm when mains power return when mains power return when mains power return Internal liner material commercial grade moulded polystyrol
Fault: warning signal visual and audible visual and audible visual and audible Type of control electronic controller
Interface / Volt-free alarm contact RS 485 / yes RS 485 / yes RS 485 / yes Temperature display external digital
Interior light LED lighting, with separate switch Power failure alarm when mains power return
Adjustable shelves 3 3 Fault: warning signal visual and audible
Usable shelf area in mm (w / d) 440 / 420 440 / 420 602 / 485 Interface / Volt-free alarm contact RS 485 / yes
Shelf material wire shelves plastic-coated wire shelves plastic-coated wire shelves plastic-coated Adjustable shelves fridge compartment 4
Shelf loading 45 kg 45 kg 60 kg Usable shelf area in mm (w / d) fridge compartment 440 / 409
Handle ergonomic slimline handle ergonomic slimline handle ergonomic slimline handle Shelf material fridge / freezer comp. wire shelves plastic-coated / glass
Lock fitted fitted fitted Shelf loading fridge / freezer comp. 45 kg / 24 kg
Self-closing door yes yes yes Drawers freezer compartment 3
Door hinges right, reversible on site right, reversible on site right, reversible on site Handle ergonomic slimline handle
Gross / net weight 46 / 43 kg 39 / 36 kg 120 / 113 kg Lock fitted
Self-closing door yes
Accessories Door hinges right, reversible on site
Shelf, plastic-coated 7112313 7112313 7112059 Gross / net weight 90 / 84 kg
Stacking kit, white 9876687 9876687
Roller bars 9590521 9590521 Accessories
Evaporator cover, white 9590523 9590523 Shelf, plastic-coated, for fridge compartment 7112313
NTC product temperature sensor 9591493 Evaporator cover, white, for fridge compartment 9590391
RS 485 / RS 232 adapter, data log software 9590387 9590387 9590387 NTC product temperature sensor 9590407
Foot pedal opener 9094579 RS 485 / RS 232 adapter, data log software 9590387
Additional lock barrels (up to 10) on request on request Roller bars 9590380
Additional lock barrels (up to 10) on request
1 Measured at +25°C ambient temperature and +5°C set temperature for fridges and -20°C for freezers * Gradient as defined in EN 60068-3: the difference between the warmest and coldest average measurements, increased by their expanded uncertainty, throughout the duration.
16 ** Max. fluctuation as per EN 60068-3: greatest fluctuation value determined throughout the duration of measurements. 17
Laboratory refrigerators and freezers with electronic controls and spark-free interior
The laboratory appliances are equipped with The electronic controller with digital temperature display
a volt-free contact for alarm forwarding to allows accurate temperature setting to 1/10°C. The large
an external remote warning system. display allows improved temperature visibility at a glance.
Access port for integration of an independent All laboratory refrigerators and freezers with spark-free interior
temperature sensor (e.g. an optionally available are tested according to the 2014/34/EU (ATEX) Directive.
NTC temperature sensor or similar measuring
instruments) in laboratory appliances.
The glass shelves of the laboratory refrigerators Laboratory appliances with a electronic controller provide 1-point calibration
with spark-free interior are height adjustable for accurate temperature control. This permits compensation between the set
and can easily be removed at a door opening temperature and the actual internal temperature.
angle of 90 °.
The dynamic cooling system in conjunction with the precise electronic controller
ensures maximum temperature stability and high temperature consistency in the interior.
LCexv 4010
18 19
Laboratory refrigerators and freezers with electronic controls and spark-free interior
+0.5°C
20 21
Laboratory fridge-freezer combination with electronic controls and spark-free interior Laboratory refrigerators and freezers with electronic controls and spark-free interior
Laboratory fridge-freezer LCexv 4010 MediLine Laboratory refrigerators and LKexv 3910 MediLine LKUexv 1610 MediLine LGex 3410 MediLine LGUex 1500 MediLine
combination with electronic controls freezers with electronic controls
and spark-free interior and spark-free interior
Total gross / net capacity fridge compartment 254 / 240 litre Total gross / net capacity 360 / 344 litre 141 / 130 litre 310 / 284 litre 139 / 129 litre
Total gross / net capacity freezer compartment 107 / 105 litre Exterior dimensions in mm (w / d / h) 597 / 615 / 1840 597 / 615 / 825 597 / 615 / 1840 597 / 615 / 825
Exterior dimensions in mm (w / d / h) 597 / 615 / 2003 Interior dimensions in mm (w / d / h) 440 / 435 / 1635 440 / 435 / 670 420 / 400 / 1587 454 / 450 / 663
Interior dimensions in mm (w / d / h) fridge compartment 440 / 441 / 1105 Energy consumption in 365 days ¹ 316 kWh 315 kWh 478 kWh 338 kWh
Interior dimensions in mm (w / d / h) freezer compartment 431 / 435 / 597 Ambient temperature range +10°C to +35°C +10°C to +35°C +10°C to +35°C +10°C to +35°C
Energy consumption in 365 days ¹ 657 kWh Refrigerant R 600a R 600a R 600a R 600a
Ambient temperature range +10°C to +35°C Sound power level 48 dB(A) 47 dB(A) 45 dB(A) 45 dB(A)
Refrigerant R 600a Voltage / Connection rating 220 – 240V~ / 1.5 A 220 – 240V~ / 1.0 A 220 – 240V~ / 1.5 A 220 – 240V~ / 1.0 A
Sound power level 52 dB(A) Cooling system / Defrost forced-air / automatic forced-air / automatic static / manual static / manual
Voltage / Connection rating 220 – 240V~ / 1.5 A Set temperature range +3°C to +16°C +3°C to +16°C −9°C to −30°C −9°C to −26°C
Cooling system fridge / freezer comp. forced-air / static Gradient * / max. fluctuation ** 5.5°C / 5.1°C 3.9°C / 4.8°C 6.9°C / 4.2°C 6.6°C / 3.3°C
Defrost fridge / freezer comp. automatic / manual External cabinet finish steel / white steel / white steel / white steel / white
Set temperature range fridge / freezer comp. +3°C to +16°C / −9°C to −30°C Door / lid material steel steel steel steel
Gradient * fridge / freezer comp. 4.0°C / 7.9°C Internal liner material commercial grade moulded polystyrol commercial grade moulded polystyrol commercial grade moulded polystyrol commercial grade moulded polystyrol
Max. fluctuation ** fridge / freezer comp. 3.9°C / 5.5°C Type of control electronic controller electronic controller electronic controller electronic controller
External cabinet finish steel / white Temperature display external digital external digital external digital external digital
Door / lid material steel Power failure alarm when mains power return when mains power return when mains power return when mains power return
Internal liner material commercial grade moulded polystyrol Fault: warning signal visual and audible visual and audible visual and audible visual and audible
Type of control electronic controller Interface / Volt-free alarm contact RS 485 / yes RS 485 / yes RS 485 / yes RS 485 / yes
Temperature display external digital Adjustable shelves 5 3
Power failure alarm when mains power return Usable shelf area in mm (w / d) 440 / 420 440 / 420 420 / 400 454 / 450
Fault: warning signal visual and audible Shelf material glass glass evaporator plates evaporator plates
Interface / Volt-free alarm contact RS 485 / yes Shelf loading 40 kg 40 kg 24 kg 24 kg
Adjustable shelves fridge compartment 4 Drawers / Number of baskets 8/– 3/1
Usable shelf area in mm (w / d) fridge compartment 440 / 409 Compartment height in mm 185 149
Shelf material fridge / freezer comp. glass / glass Handle ergonomic slimline handle ergonomic slimline handle ergonomic slimline handle ergonomic slimline handle
Shelf loading fridge / freezer comp. 45 kg / 24 kg Lock fitted fitted fitted fitted
Drawers freezer compartment 3 Self-closing door / Door hinges yes / right, reversible on site yes / right, reversible on site yes / right, reversible on site yes / right, reversible on site
Handle ergonomic slimline handle Gross / net weight 74 / 68 kg 41 / 38 kg 91 / 86 kg 44 / 42 kg
Lock fitted
Self-closing door / Door hinges yes / right, reversible on site Accessories
Gross / net weight 93 / 87 kg Glass shelf 9293629 9293629
Stacking kit, white 9876687 9876687
Accessories Roller bars 9590380 9590521 9590380 9590521
Glass shelf 9293629 Evaporator cover, white 9590241 9590523
NTC product temperature sensor 9590145 Adjustable legs 9590231 9590231
RS 485 / RS 232 adapter, data log software 9590387 NTC product temperature sensor 9590145 9590145 9590145 9590145
Roller bars 9590380 RS 485 / RS 232 adapter, data log software 9590387 9590387 9590387 9590387
Additional lock barrels (up to 10) on request Additional lock barrels (up to 10) on request on request on request on request
1 Measured at +25°C ambient temperature and +5°C set temperature for fridges and -20°C for freezers * Gradient as defined in EN 60068-3: the difference between the warmest and coldest average measurements, increased by their expanded uncertainty, throughout the duration.
22 ** Max. fluctuation as per EN 60068-3: greatest fluctuation value determined throughout the duration of measurements. 23
Laboratory refrigerators with analogue controls and spark-free interior
Glass shelves.
The integrated lock is exceedingly The glass shelves ensure secure storage even for small
sturdy and protects the stored products items and have a loading capacity of up to 40 kg.
against unauthorised access.
LKexv 5400
24 25
Laboratory refrigerators with analogue controls and spark-free interior
Laboratory refrigerators LKexv 5400 MediLine LKexv 3600 MediLine LKexv 2600 MediLine LKexv 1800 MediLine
with mechanical control and
spark-free interior
Total gross / net capacity 554 / 520 litre 333 / 307 litre 240 / 221 litre 180 / 160 litre
Exterior dimensions in mm (w / d / h) 750 / 730 / 1640 600 / 610 / 1640 600 / 610 / 1250 600 / 600 / 860
Interior dimensions in mm (w / d / h) 600 / 560 / 1452 470 / 440 / 1452 470 / 440 / 1062 513 / 441 / 702
Energy consumption in 365 days ¹ 359 kWh 346 kWh 287 kWh 328 kWh
Ambient temperature range +10°C to +40°C +10°C to +40°C +10°C to +40°C +10°C to +30°C
Refrigerant R 600a R 600a R 600a R 600a
Sound power level 48 dB(A) 48 dB(A) 48 dB(A) 47 dB(A)
Voltage / Connection rating 220 – 240V~ / 1.5 A 220 – 240V~ / 1.5 A 220 – 240V~ / 1.0 A 220 – 240V~ / 1.0 A
Cooling system forced-air forced-air forced-air forced-air
Defrost automatic automatic automatic automatic
Set temperature range +1°C to +15°C +1°C to +15°C +1°C to +15°C +1°C to +15°C
Gradient * / max. fluctuation ** 6.9°C / 5.8°C 4.8°C / 3.0°C 6.4°C / 5.5°C 10.2°C / 7.4°C
External cabinet finish steel / white steel / white steel / white steel / white
Door / lid material steel steel steel steel
Internal liner material commercial grade moulded polystyrol commercial grade moulded polystyrol commercial grade moulded polystyrol commercial grade moulded polystyrol
Type of control analogue control analogue control analogue control analogue control
Temperature display external digital external digital external digital external digital
Adjustable shelves 5 5 4 3
Usable shelf area in mm (w / d) 600 / 550 470 / 425 470 / 425 513 / 412
Shelf material glass glass glass glass
Shelf loading 40 kg 40 kg 40 kg 40 kg
Handle ergonomic slimline handle ergonomic slimline handle ergonomic slimline handle ergonomic slimline handle
Lock fitted fitted fitted fitted
Door hinges right, reversible on site right, reversible on site right, reversible on site right, reversible on site
Gross / net weight 84 / 77 kg 64 / 59 kg 53 / 49 kg 41 / 38 kg
Accessories
Glass shelf 9293613 9293615 9293615 9293631
Castor base 9086365 9086323 9086323
Adjustable legs 9590231 9590231 9590231
Additional lock barrels (up to 10) on request on request on request
1 Measured at +25°C ambient temperature and +5°C set temperature * Gradient as defined in EN 60068-3: the difference between the warmest and coldest average measurements, increased by their expanded uncertainty, throughout the duration.
26 ** Max. fluctuation as per EN 60068-3: greatest fluctuation value determined throughout the duration of measurements. 27
Laboratory chest freezers down to - 45°C
Visual and audible temperature Sturdy, one-piece and easy-to-clean lid. The strong
alarms alert the user if lid hinges are designed for at least 50,000 openings.
temperature deviation limits
are exceeded. The parameters
for the temperature alarm can be
The aluminium handle on the
individually set. The integrated
LGT models is simple and tough
data memory with min/max
for intensive commercial use. All
temperatures logs temperature fluctuations with date, time and duration
appliances have locks as standard.
of the alarm. In addition the electronic controller ensures high temperature
consistency in the interior. All laboratory chest freezers are designed in
accordance with ISO 60068 -3.
Volt-free contact for forwarding alarms to an external remote The lid has an integrated,
warning system. energy-efficient LED interior light
to improve visibility in the interior.
The StopFrost system fitted to the LGT models reduces Laboratory chest freezers are equipped with
frosting of the interior and the freezer contents – so the time- 1-point calibration for accurate temperature control.
consuming process of defrosting is necessary far less often.
The vacuum is also equalised quickly after the lid is opened
and closed so that the chest can be re-opened effortlessly.
LGT 2325
28
28 29
9
Laboratory chest freezers down to - 45°C
+0.5°C
30 31
Laboratory chest freezers down to - 45°C
Laboratory chest freezers LGT 4725 MediLine LGT 3725 MediLine LGT 2325 MediLine
down to - 45°C
Total gross / net capacity 459 / 431 litre 365 / 342 litre 215 / 200 litre
Exterior dimensions in mm (w / d / h) 1648 / 808 / 919 1373 / 808 / 919 1132 / 760 / 919
Interior dimensions in mm (w / d / h) 1445 / 500 / 650 1170 / 500 / 650 889 / 410 / 630
Energy consumption in 365 days ¹ 1589 kWh 1069 kWh 824 kWh
Ambient temperature range +10°C to +32°C +10°C to +30°C +10°C to +30°C
Refrigerant R 290 R 290 R 290
Sound power level 55 dB(A) 55 dB(A) 55 dB(A)
Voltage / Connection rating 220 – 240V~ / 3.5 A 220 – 240V~ / 3.0 A 220 – 240V~ / 2.0 A
Cooling system static static static
Defrost manual manual manual
Set temperature range −10°C to −45°C −10°C to −45°C −10°C to −45°C
Gradient * / max. fluctuation ** 3.5°C / 1.8°C 4.3°C / 2.2°C 4.7°C / 1.9°C
External cabinet finish steel / white steel / white steel / white
Door / lid material steel steel steel
Internal liner material white coated aluminium white coated aluminium white coated aluminium
Type of control electronic controller electronic controller electronic controller
Temperature display external digital external digital external digital
Power failure alarm when mains power return when mains power return when mains power return
Interface / Volt-free alarm contact RS 485 / yes RS 485 / yes RS 485 / yes
Insulation 100 mm 100 mm 120 mm
Number of baskets 0 0 0
Number of baskets, max 16 13 10
Interior light LED LED LED
Handle profiled aluminium profiled aluminium profiled aluminium
Lock fitted fitted fitted
Gross / net weight 94 / 81 kg 82 / 71 kg 68 / 58 kg
Accessories
NTC product temperature sensor 9590407 9590407 9590407
RS 485 / RS 232 adapter, data log software 9590387 9590387 9590387
Basket large 479×210×210 mm 7113627 7113627
Basket small 385×202×195 mm 7112317
1 Measured at +25°C ambient temperature and -45°C set temperature * Gradient as defined in EN 60068-3: the difference between the warmest and coldest average measurements, increased by their expanded uncertainty, throughout the duration.
32 ** Max. fluctuation as per EN 60068-3: greatest fluctuation value determined throughout the duration of measurements. 33
Accessories
Additional U-shaped trayslides and plastic-coated grid shelves can be retrofitted as required to provide extra storage options. The
sturdy grid shelves have an extremely high loading capacity of up to 60 kg.
A special interface converter including the Liebherr LTM monitoring software is available for central documentation of the
temperature profile data and alarm events of multiple appliances via the RS 485 serial interface. It is possible to network as many
as 20 laboratory appliances and centrally document their parameters. Alarm forwarding or regular status reports to up to three
email addresses can be confi gured as an additional feature. Alternatively, commercially available converters can be used to
connect the appliances to a PC via WLAN or LAN. Software requirements: PC with Windows ® operating system.
An NTC product temperature sensor for logging product temperatures is available as a retrofit kit for the laboratory appliances with
electronic controller. The logged product temperatures can either be read by the electronic controller or transferred to an external
documentation system via the existing RS 485 interface.
The optional foot-pedal opener is useful when you don't have a hand free.
A special interface converter including LTM monitoring software is available for central documentation of the temperature profile
data and alarm events of multiple appliances via the RS 485 serial interface. Capability is provided for interconnecting as many
as 20 laboratory appliances and centrally documenting their parameters. Alarm forwarding or regular status reports to up to three
email addresses can be configured as an additional feature. Alternatively commercially available converters can be used to connect
the appliances to a PC via WLAN or LAN. Software requirements: PC with Windows® operating system.
An NTC product temperature sensor for logging product temperatures is available as a retrofit kit for the laboratory appliances with
electronic controller. The logged product temperatures can either be read by the electronic controller or transferred to an external
documentation system via the existing RS 485 interface.
34 35
Accessories
Up to 10 additional lock barrels to protect the stored products against unauthorised access are available as accessories for the Additional plastic-coated grid shelves can be retrofitted as required to provide extra storage options. The sturdy grid shelves have
laboratory appliances with electronic controller. In case of multiple appliances, different locks can be installed to ensure that the an extremely high loading capacity of up to 60 kg.
respective appliance can only be accessed by the staff members responsible for it.
A stacking kit is available as an accessory for combining the LKUv 1613, LKUv 1610, LKUexv 1610 and LGUex 1500 models as An NTC product temperature sensor without metal sheath is available as a retrofit kit for registering product temperatures. The registering
desired. This allows stacking a glass door appliance and solid door appliance or a refrigerator and freezer on a small footprint. temperatures can either be read by the control system or transferred to an external documentation system via the RS 485 interface.
An evaporator cover can be installed for added safety, to ensure that cold-sensitive products cannot touch the evaporator. A special interface converter including LTM monitoring software is available for central documentation of the temperature profile data
and alarm events of multiple appliances via the RS 485 serial interface. Capability is provided for interconnecting as many as 20
laboratory appliances and centrally documenting their parameters. Alarm forwarding or regular status reports to up to three email
addresses can be configured as an additional feature. Commercially available converters can be used to connect the connected
appliances to a PC via WLAN or LAN. Software requirements: PC with Windows® operating system.
The optional foot-pedal opener is useful when you don't have a hand free. Up to 10 additional lock barrels to protect the stored products against unauthorised access are available as accessories for the
laboratory appliances with electronic controller. In case of multiple appliances, different locks can be installed to ensure that the
respective appliance can only be accessed by the staff members responsible for it.
30 mm high roller sets can be retrofitted to the under-worktop LKUv models and height-adjustable legs can be retrofitted to the Additional glass shelves can be retrofitted to the LCexv, LKexv and LKUexv models as required to provide extra storage options. The
upright LKv models. The legs are adjustable between 115 mm and 170 mm in height. glass shelves made of toughened safety glass meet the standards for spark-free refrigerators in accordance with ATEX and have a
loading capacity of up to 40 kg.
36 37
Accessories
A stacking kit is available as an accessory for combining the LKUexv and LGUex models as well as other under-worktop models in Up to 10 additional lock barrels to protect the stored products against unauthorised access are available as accessories for the
the LKUv range. This allows stacking laboratory fridge-freezers on a small footprint. laboratory appliances. In case of multiple appliances, different locks can be installed to ensure that the respective appliance can only
be accessed by the staff members responsible for it.
30 mm high roller sets can be retrofitted to the under-worktop LKUexv models and height-adjustable legs can be retrofitted to the An NTC product temperature sensor for logging product temperatures is available as a retrofit kit for the laboratory chest freezers.
upright LKexv models. The legs are adjustable between 115 mm and 170 mm in height. The logged product temperatures can either be read by the electronic controller or transferred to an external documentation system
via the existing RS 485 interface.
An evaporator cover can be installed for added safety, to ensure that cold-sensitive products cannot touch the evaporator. A special interface converter including LTM documentation software is available for central documentation of the temperature
profile data and alarm events of multiple appliances via the RS 485 serial interface. It is possible to network as many as 20
laboratory appliances and centrally monitor their parameters. Alarm forwarding or regular status reports to up to three email
addresses can be configured as an additional feature. Commercially available converters can be used to connect the connected
appliances to a PC via WLAN or LAN. Software requirements: PC with Windows ® operating system.
Section: Laboratory refrigerators with analogue controls
and spark-free interior
Glass shelves Baskets
Additional glass shelves can be retrofitted to the LKexv models as required to provide extra storage options. The glass shelves made The optional baskets provide an optimum overview of the stored preparations and can help to improve the handling and organising
of toughened safety glass meet the standards for spark-free refrigerators in accordance with ATEX and have a loading capacity of of the freezer contents.
up to 40 kg.
Castor base
A castor base is available as an accessory for the LKexv 5400, 3600 and 2600 models to allow flexible use of the appliances in
different rooms.
Adjustable legs
Adjustable-height legs can be retrofitted to the LKexv 5400, 3600 and 2600 models for easy cleaning underneath. They are adjustable
between 115 mm and 170 mm in height.
38 39
Liebherr commercial appliances can be found at
specialist retailers where providing first-class service
and expert advice is their top priority.
You can find an overview of all Liebherr appliances in our main catalogues. Available in stores or on home.liebherr.com.
apps.home.liebherr.com
The Liebherr-Hausgeräte YouTube channel provides News, product launches and special promotions
Learn all about our
interesting and helpful films showing you the functions can be found on our Facebook page, the Liebherr
current social media
of Liebherr refrigerators and freezers. blog, on Instagram and Pinterest.
channels.
socialmedia.home.
liebherr.com
home.liebherr.com
40